Sure-Lites DESCRIPTION Type Catalog # The Sure-Lites SEL LED remote series reduces overall cost and design time for a UL924 compliant emergency egress system. Key features include market leading spacing to reduce the number of fixtures required; universal voltage input from 4.8V through 12V and wet location rating as standard to reduce design time and mistake proof the ordering process; an LED source to eliminate lamp maintenance along with the quality and reliability you expect from Eaton products. Project Date Comments Prepared by SPECIFICATION FEATURES ELECTRICAL - 4.8 V through 12 V input voltage - 90 lumen, 200 lumen and 285 lumen LED options - Universal polarity wiring Metal Housing: - Lamp housing made of corrosion resistant 22 gauge die formed spun aluminum. - Available in white, grey and black finishes - specify when ordering - Lamp heads adjust 80° from vertical with 358° rotation MECHANICAL Plastic Housing: - Flame and impact resistant injection molded thermoplastic housing MOUNTING - Available in white, grey and black - Aluminum mounting plate finishes - specify when ordering mounts flush on wall or ceiling - Lamp heads adjust 80° from - Designed for installation on vertical with 358° rotation standard electrical box ENVIRONMENTAL - All remotes are wet location - Temperature rating -30°C to 60°C WARRANTY - 5 year limited warranty - UL 924 Listed ACCESSORIES - Wireguard WG8 for use with single head remotes - Wireguard WG9 for use with double head remotes SRP H OW TO S P E C I F I Y LED remote with 4.8 V through 12 V input, -30°C to 60°C temperature rating and up to 60 feet of coverage. DIMENSIONS SRP Single SRPD SRP Double 4.5” [114mm] 4.5” [114mm] 4.7” [119mm] 4.7” [119mm] 6.3” [161mm] 6.0” [153mm] SRM 4.9” [124mm] 8.5” [215mm] SRM Single SRM Double 4.5” [114mm] 4.5” [114mm] SRMD 4.6” [117mm] 7.2” [182mm] 4.6” [117mm] 6.8” [173mm] 4.5” [115mm] SEL Series Remote LED Emergency Light 8.1” [207mm] TD505008EN 3/10/2016 SEL Series Remote ORDERING INFORMATION SAMPLE NUMBER: SRP13WH Series Material Coverage Number of Heads Color SR= Sure-Lites remote P=Polycarbonate M=Aluminum 13=13 feet 25=25 feet 30=30 feet __=Single WH=White BK=Black GY=Grey Series Material Coverage Number of Heads Color SR= Sure-Lites remote P=Polycarbonate M=Aluminum 25=25 feet 50=50 feet 60=60 feet D=Double WH=White BK=Black GY=Grey E N E R G Y D ATA S PA C I N G S C H A R T Amp (A) Watt (W) SRM13 / SRP13 0.25 1.25 SRM25 / SRP25 0.5 2.5 SRM30 / SRP30 1.0 4.1 SRM25D / SRP25D 0.50 2.50 SRM50D / SRP50D 1.0 5.0 SRM60D / SRP60D 2.0 8.2 Double Head Coverage at 0.1 foot candle minimum Double Head Coverage at 1.0 foot candle minimum Output Lumens 7.5 foot height 20 foot height 7.5 foot height SRP25D/SRM25D 90 30 15 12 12 SRP50D/SRM50D 200 49 33 18 22 SRP60D/SRM60D 285 65 52 15 27 Catalog Logic 20 foot height P H OTO M E T RY SRP25D AND SRM25D - 0.1 Fc min 30ft 1.0 0.8 0.2 0.2 0.8 1.1 1.2 0.9 0.5 0.3 0.2 0.1 0.1 0.1 0.1 0.2 0.3 0.5 0.9 1.2 2.8 1.4 0.3 0.3 1.4 2.8 3.5 1.7 0.7 0.4 0.2 0.1 0.1 0.1 0.1 0.2 0.4 0.7 1.7 3.5 3.6 1.6 0.4 0.4 1.6 3.6 3.8 1.6 0.6 0.4 0.2 0.1 0.1 0.1 0.1 0.2 0.4 0.6 1.6 3.8 1 2 1.1 0.8 0.2 0.2 0.8 1.1 1.2 0.9 0.5 0.3 0.2 0.1 0.1 0.1 0.1 0.2 0.3 0.5 0.9 1.2 2.9 1.4 0.4 0.4 1.4 2.9 3.5 1.7 0.7 0.4 0.2 0.1 0.1 0.1 0.1 0.2 0.4 0.7 1.7 3.5 3.6 1.6 0.4 0.4 1.6 3.6 3.8 1.6 0.6 0.4 0.2 0.1 0.1 0.1 0.1 0.2 0.4 0.6 1.6 3.8 13 1 2 14 13 14 1.1 0.8 0.2 0.2 0.8 1.1 1.2 0.9 0.5 0.3 0.2 0.1 0.1 0.1 0.1 0.2 0.3 0.5 0.9 1.2 2.9 1.4 0.4 0.4 1.4 2.9 3.5 1.7 0.7 0.4 0.2 0.1 0.1 0.1 0.1 0.2 0.4 0.7 1.7 3.5 3.6 1.6 0.4 0.4 1.6 3.6 3.8 1.6 0.6 0.4 0.2 0.1 0.1 0.1 0.1 0.2 0.4 0.6 1.6 3.8 15 16 15 16 1.5’ Away from Wall 3’ Away from Wall 4.5’ Away from Wall Illuminance Values(Fc) Average = 1.27 Maximum = 3.8 Minimum = 0.1 Avg/Min Ratio = 12.70 Max/Min Ratio = 38.00 No. Points = 44 Illuminance Values(Fc) Average = 1.18 Maximum = 3.5 Minimum = 0.1 Avg/Min Ratio = 11.80 Max/Min Ratio = 35.00 No. Points = 44 Illuminance Values(Fc) Average = 0.56 Maximum = 1.2 Minimum = 0.1 Avg/Min Ratio = 5.60 Max/Min Ratio = 12.00 No. Points = 44 1.1 0.8 0.2 0.2 0.8 1.0 2.8 1.4 0.3 0.3 1.3 2.8 3.6 1.6 0.4 0.4 1.6 3.6 17 18 17 18 Lum. No. Label X Y Z Orient Tilt 1 P26739 4.75 0.33 7.5 158 34 2 P26739 5.25 0.33 7.5 22 34 13 P26739 34.75 0.33 7.5 158 34 14 P26739 35.25 0.33 7.5 22 34 15 P26739 64.75 0.33 7.5 158 34 16 P26739 65.25 0.33 7.5 22 34 17 P26739 94.75 0.33 7.5 158 34 18 P26739 95.25 0.33 7.5 22 34 30 ft. ***The “Rule of Thumb” spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 foot ceiling with a 6 foot wide walkway and 3 foot path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.5 feet. Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance. SEL Series Remote P H OTO M E T RY SRM50D and SRP50D - 0.1 Fc min 0.2 0.2 0.2 0.2 0.3 0.4 0.6 1.0 1.5 2.1 2.4 2.1 1.5 1.1 0.2 0.2 0.1 0.1 0.3 1.3 1.7 2.3 2.4 1.9 1.3 0.8 0.6 0.4 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.5 0.7 1.1 1.7 2.3 2.4 1.9 0.1 0.2 0.2 0.2 0.3 0.4 0.7 1.1 1.8 3.0 3.9 3.6 2.4 1.7 0.3 0.2 0.2 0.2 0.8 1.9 2.8 3.8 3.7 2.5 1.5 0.9 0.6 0.4 0.3 0.2 0.2 0.2 0.1 0.2 0.2 0.2 0.2 0.3 0.5 0.8 1.3 2.1 3.4 3.9 3.3 0.1 0.1 0.2 0.2 0.3 0.4 0.5 0.8 1.4 2.2 3.1 3.2 2.5 1.8 0.3 0.2 0.2 0.2 0.8 2.0 2.7 3.3 2.8 1.9 1.2 0.7 0.5 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.4 0.6 1.0 1.6 2.5 3.3 3.0 1 2 MH: 7.5 MH: 7.5 34 MH: 7.5 MH: 7.5 56 MH: 7.5 MH: 7.5 7 8 MH: 7.5 MH: 7.5 49ft 1.5’ Away from Wall 3’ Away from Wall 4.5’ Away from Wall Illuminance Values(Fc) Average = 1.03 Maximum = 3.3 Minimum = 0.1 Avg/Min Ratio = 10.30 Max/Min Ratio = 33.00 No. Points = 44 Illuminance Values(Fc) Average = 1.22 Maximum = 3.9 Minimum = 0.1 Avg/Min Ratio = 12.20 Max/Min Ratio = 39.00 No. Points = 44 Illuminance Values(Fc) Average = 0.87 Maximum = 2.4 Minimum = 0.1 Avg/Min Ratio = 8.70 Max/Min Ratio = 24.00 No. Points = 44 Lum. No. Label X Y Z Orient Tilt 1 P26834 4_8V 199 lumen acrylic -0.25 0.5 7.5 165 52 2 P26834 4_8V 199 lumen acrylic 0.25 0.5 7.5 15 52 3 P26834 4_8V 199 lumen acrylic 48.75 0.5 7.5 165 52 4 P26834 4_8V 199 lumen acrylic 49.25 0.5 7.5 15 52 5 P26834 4_8V 199 lumen acrylic 97.75 0.5 7.5 165 52 6 P26834 4_8V 199 lumen acrylic 98.25 0.5 7.5 15 52 7 P26834 4_8V 199 lumen acrylic 146.75 0.5 7.5 165 52 8 P26834 4_8V 199 lumen acrylic 147.25 0.5 7.5 15 52 49 ft. SRP60D AND SRM60D - 0.2 Fc min 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.5 0.7 0.9 1.2 1.4 1.6 1.6 1.4 1.2 0.8 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.8 1.2 1.4 1.6 1.6 1.4 1.2 0.9 0.7 0.5 0.4 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.4 0.5 0.7 0.9 1.3 1.7 2.2 2.8 3.3 3.3 2.5 1.7 0.8 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.9 1.7 2.5 3.3 3.4 2.8 2.2 1.7 1.3 0.9 0.7 0.5 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.4 0.5 0.7 1.0 1.3 1.8 2.4 3.1 3.9 4.6 3.8 2.4 1.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 1.4 2.4 3.8 4.6 3.9 3.1 2.4 1.8 1.3 1.0 0.7 0.5 0.4 0.3 1 2 MH: 7.5 MH: 7.5 65ft 23 25 MH: 7.5 MH: 7.5 1.5’ Away from Wall 3’ Away from Wall 4.5’ Away from Wall Illuminance Values(Fc) Average = 1.35 Maximum = 4.6 Minimum = 0.2 Avg/Min Ratio = 6.75 Max/Min Ratio = 23.00 No. Points = 44 Illuminance Values(Fc) Average = 1.11 Maximum = 3.4 Minimum = 0.2 Avg/Min Ratio = 5.55 Max/Min Ratio = 17.00 No. Points = 44 Illuminance Values(Fc) Average = 0.65 Maximum = 1.6 Minimum = 0.2 Avg/Min Ratio = 3.25 Max/Min Ratio = 8.00 No. Points = 44 24 26 MH: 7.5 MH: 7.5 Lum. No. Label X Y Z Orient Tilt 1 P27192 -0.25 0.5 7.5 175 62 2 P27192 0.25 0.5 7.5 5 62 23 P27192 66.25 0.5 7.5 5 62 24 P27192 130.25 0.5 7.5 5 62 25 P27192 64.75 0.5 7.5 175 62 26 P27192 129.75 0.5 7.5 175 62 65 ft. ***The “Rule of Thumb” spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 foot ceiling with a 6 foot wide walkway and 3 foot path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.5 feet. Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice.