Metalux D ES C R IPTION ArcLine is a premium grade specification lensed troffer series. This innovative, high quality luminaire is dedicated to the latest solid state lighting and driver technology for optimal performance and energy efficiency. The ArcLine is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The ArcLine series features efficiency, quality and performance. The series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by S PEC IFIC A TION FEA T U R E S Construction Rigid housing is die formed of code gauge prime cold rolled steel and features full length die-formed stiffeners and unibody endplate for added strength. Side flanges are hemmed. Innovative design provides superior lens brightness uniformity and visual comfort. Unibody endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. Ample KOs are provided for continuous row wiring. Endplates have integral Grid-lock feature for safety and convenience. Controls The ArcLine LED is Powered by Fifth Light, with a standard 0-10V continuous dimming driver that works with any 0-10V control/ dimmer. Combine with energy saving products like occupancy sensors, daylighting controls and lighting relay panels to maximize energy savings. In addition, the ArcLine can include a factoryinstalled integrated sensor system for occupancy and daylight dimming control and manual control from an optional handheld remote. Or, specify the Digital Addressable Lighting Interface (DALI) drivers, dimmable down to 10%, for use with Fifth Light controls. See ordering information for details on all three options. Housing and ballast cover finished with new 90% reflective white enamel for superior performance. E le ctrica l H inging/Latching Long-Life LED system coupled with electrical driver to deliver optimal performance. LED’s available in 3000k, 3500k or 4000k with a CRI ≥ 85. Projected life is 60,000 hours at 89% lumen output. cULus listed. Electronic drivers are available for 120-277V applications. Positive cam action steel latches with baked white enamel finish. Safety-lock T-hinges allow hinging and latching either side. Door assembly hinges down for easy access from below without tools. E me rg e n cy Ba ttery Pack Option Optional 120v-277v integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 90-minute batteries provide constant power to the LED system, ensuring codecompliance. A test switch/indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. See ordering information for details. F in ish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. CURVED Frame/Sheilding Die formed, heavy gauge, flat steel door with reinforced mitered corners and painted after fabrication, baked matte white enamel finish. Positive light seals. Acrylic frosted lens. Compliance Modules are UL recognized components and indoor luminaires are cULus listed for 25ºC ambient environments, RoHS compliant, and LED modules comply with IESNA LM-79 and LM-80 standards. DesignLights Consortium™ Qualified and classified for DLC Standard, refer to www. designlights.org for details. Warranty Five year warranty. RECTILINEAR 22ALN LED 2' X 2' TROFFER LED MODULE Specification Grade Troffer CURVED 3-1/4" [83mm] 23-3/4" [603mm] RECTILINEAR 3-1/4" [83mm] CERTIFICATION DATA 23-3/4" [603mm] D OOR FR A M ES M O U NT ING D A T A A LN F la t , W h it e St e e l cULus 1598 Damp Location Listed IC Rated LM79/LM80 Compliant ROHS Compliant DesignLights Consortium™ Qualified 23-3/4" [603mm] Safe and convenient means of disconnecting power 23-3/4" [603mm] PS519060EN 2016-03-31 2 2 ALN LE D C EIL ING C OM PA TIB ILITY G Grid/Lay-in Standard G Concealed T G Slot Grid Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid G G G (Verify compatibility/ consult factory.) ENERGY A ND PER FOR M AN C E DAT A B Y C AT AL O G N U M B E R Stock or MTO* Catalog Logic (Curved Shielding) L UME N MA INT E NA NCE Delivered Lumens Watts Efficacy (lm/W) MTO 22ALNG-LD4-20-UNV-L830-CD1-U 2006 20.3 99 MTO 22ALNG-LD4-20-UNV-L835-CD1-U 2184 20.3 108 MTO 22ALNG-LD4-20-UNV-L840-CD1-U 2302 20.3 113 MTO 22ALNG-LD4-25-UNV-L830-CD1-U 2402 24.7 97 STOCK 22ALNG-LD4-25-UNV-L835-CD1-U 2615 24.7 106 STOCK 22ALNG-LD4-25-UNV-L840-CD1-U 2756 24.7 112 MTO 22ALNG-LD4-31-UNV-L830-CD1-U 2786 29.2 95 MTO 22ALNG-LD4-31-UNV-L835-CD1-U 3034 29.2 104 MTO 22ALNG-LD4-31-UNV-L840-CD1-U 3196 29.2 109 MTO 22ALNG-LD4-35-UNV-L830-CD1-U 3197 34.5 93 STOCK 22ALNG-LD4-35-UNV-L835-CD1-U 3482 34.5 101 STOCK 22ALNG-LD4-35-UNV-L840-CD1-U 3669 34.5 106 MTO 22ALNG-LD4-40-UNV-L830-CD1-U 3596 40.0 90 MTO 22ALNG-LD4-40-UNV-L835-CD1-U 3916 40.0 98 MTO 22ALNG-LD4-40-UNV-L840-CD1-U 4126 40.0 103 MTO 22ALNG-LD4-44-UNV-L830-CD1-U 4017 46.4 87 MTO 22ALNG-LD4-44-UNV-L835-CD1-U 4375 46.4 94 MTO 22ALNG-LD4-44-UNV-L840-CD1-U 4609 46.4 99 Ambient Temperature TM-21 Lumen Maintenance (60,000 hours) Theoretical L70 (Hours) 25°C > 89% > 199,000 *Made to order (MTO) requires a typical four week lead time. Stock or MTO* Catalog Logic (Rectilinear Shielding) Delivered Lumens Watts Efficacy (lm/W) MTO 22ALNG-LD4-20-R-UNV-L830-CD1-U 2102 20.8 101 MTO 22ALNG-LD4-20-R-UNV-L835-CD1-U 2164 20.8 104 MTO 22ALNG-LD4-20-R-UNV-L840-CD1-U 2199 20.8 106 MTO 22ALNG-LD4-25-R-UNV-L830-CD1-U 2523 25.5 99 STOCK 22ALNG-LD4-25-R-UNV-L835-CD1-U 2598 25.5 102 STOCK 22ALNG-LD4-25-R-UNV-L840-CD1-U 2640 25.5 104 MTO 22ALNG-LD4-31-R-UNV-L830-CD1-U 2965 30.3 98 MTO 22ALNG-LD4-31-R-UNV-L835-CD1-U 3053 30.3 101 MTO 22ALNG-LD4-31-R-UNV-L840-CD1-U 3102 30.3 102 MTO 22ALNG-LD4-35-R-UNV-L830-CD1-U 3361 35.0 96 STOCK 22ALNG-LD4-35-R-UNV-L835-CD1-U 3461 35.0 99 STOCK 22ALNG-LD4-35-R-UNV-L840-CD1-U 3516 35.0 100 MTO 22ALNG-LD4-40-R-UNV-L830-CD1-U 3802 41.1 92 MTO 22ALNG-LD4-40-R-UNV-L835-CD1-U 3915 41.1 95 MTO 22ALNG-LD4-40-R-UNV-L840-CD1-U 3978 41.1 97 MTO 22ALNG-LD4-44-R-UNV-L830-CD1-U 4185 46.6 90 MTO 22ALNG-LD4-44-R-UNV-L835-CD1-U 4309 46.6 93 MTO 22ALNG-LD4-44-R-UNV-L840-CD1-U 4378 46.6 94 *Made to order (MTO) requires a typical four week lead time. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. PS519060EN 2016-03-31 2 2 ALN LE D PH OTOM ETR IC S 90˚ 75˚ 350 60˚ 700 45˚ 22ALNG-LD4-25UNV-L835-CD1-U Candlepower Electronic Driver 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Angle Linear LED 3500K Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.2 x mounting height Lumens: 2615 1050 0˚ 15˚ Input Watts: 24.7W 30˚ Efficacy: 105.9 lm/W Test Report: 22ALNG-LD4-25UNV-L835-CD1-U.IES C o e f fi c i e n t s o f U t i l i z a t i o n Effective floor cavity reflectance rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 70 80% 50 30 10 119 109 99 90 83 76 70 65 61 57 53 119 104 91 80 71 63 57 52 47 44 40 119 96 78 65 56 48 42 37 33 30 27 119 100 84 72 62 55 48 43 39 35 32 45° Across 989 985 967 937 894 840 779 713 643 570 495 421 348 277 207 140 80 33 0 989 985 968 939 899 851 795 735 669 599 526 452 379 309 241 175 112 46 0 989 982 967 944 909 869 821 764 701 631 557 485 410 338 268 198 120 45 0 90˚ 75˚ 450 60˚ 900 45˚ 70 10 116 106 96 88 81 74 69 64 59 56 52 116 102 89 78 70 62 56 51 47 43 40 116 94 77 65 55 48 42 37 33 30 27 22ALNG-LD4-35UNV-L835-CD1-U Electronic Driver Linear LED 3500K Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.2 x mounting height 0˚ 15˚ Input Watts: 40.0W 30˚ Efficacy: 87.0 lm/W Test Report: 22ALNG-LD4-35UNV-L835-CD1-U.IES C o e f fi c i e n t s o f U t i l i z a t i o n Effective floor cavity reflectance 50 50% 30 10 111 98 85 75 67 60 54 50 45 42 39 111 94 80 69 60 53 47 42 38 35 32 111 91 76 64 54 47 41 37 33 30 27 50 30% 30 10 50 10% 30 10 106 94 82 73 65 58 53 48 44 41 38 106 91 78 67 59 52 46 41 38 34 31 102 90 79 70 63 56 51 47 43 40 37 102 88 75 65 57 51 45 41 37 34 31 106 89 74 62 54 47 41 36 33 30 27 102 86 72 61 53 46 41 36 32 29 27 0% 0 100 84 70 59 51 44 39 34 31 28 25 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 70 80% 50 30 10 119 109 99 90 83 76 71 65 61 57 53 119 104 91 80 71 63 57 52 47 44 40 119 96 78 65 56 48 42 37 33 30 27 119 100 84 72 62 55 48 43 39 35 32 Zone 0-30 0-40 1211 46.3 0-40 1613 46.3 0-60 2078 79.5 0-60 2768 79.5 0-90 2615 100.0 0-90 3481 100.0 0-180 2615 100.0 0-180 3481 100.0 Specifications and dimensions subject to change without notice. Lumens 1000 1318 1311 1289 1252 1199 1132 1059 978 891 797 700 602 506 411 322 233 149 61 0 Across 1318 1308 1287 1256 1210 1155 1092 1017 932 840 745 645 546 448 354 263 158 61 0 20% 10 50 50% 30 10 50 30% 30 10 50 10% 30 10 116 106 96 88 81 74 69 64 59 56 52 116 102 89 78 70 62 56 51 47 43 40 116 94 77 65 55 48 42 37 33 30 27 111 98 85 75 67 60 54 50 45 42 39 111 94 80 69 60 53 47 42 38 35 32 106 94 82 73 65 58 53 48 44 41 38 106 91 78 67 59 52 46 41 38 34 31 102 90 79 70 63 56 51 47 43 40 37 102 88 75 65 57 51 45 41 37 34 31 Zone 0-30 % Fixture 28.7 45° 1318 1312 1288 1247 1190 1118 1040 951 855 758 659 559 463 365 273 185 104 44 0 70 Zonal Lumen Summary Lumens 751 Along II 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 70% 50 30 Zonal Lumen Summary Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Candlepower Angle Lumens: 3481 1350 20% 70% 50 30 116 98 83 71 61 54 48 43 39 35 32 Along II 116 98 83 71 61 54 48 43 39 35 32 111 91 76 64 54 47 41 37 33 30 27 106 89 74 62 54 47 41 36 33 30 27 0% 0 102 86 72 61 53 46 41 36 32 29 27 100 84 70 59 51 44 39 34 31 28 25 % Fixture 28.7 PS519060EN 2016-03-31 2 2 ALN LE D ORDER ING INFOR M A TION SAMPLE NUMBER: 22ALNG-LD4-35-R-UNV-L835-CD1-U Rating Blank= Standard ATW-SW4= Chicago Rated Series (7) 22ALN=2x2 ArcLine Series Trim Type G=Grid/Lay-in (Standard) (1) G=Concealed T G=Slot Grid Door Frame Standard=Flat White Steel Door (Leave Blank) Product Family S=Integrated Sensor Lamp Type LD4=LED 4.0 Stock Lumen Output 25=2500 Lumen 35=3500 Lumen MTO Lumen Output 20=2000 Lumen 31=3100 Lumen 40=4000 Lumen 44=4400 Lumen Shielding [Blank]=Smooth Frosted Acrylic, Curved (Standard) R=Smooth Frosted Acrylic, Rectilinear RDP=Rectilinear with Round Pattern Insert Occupancy Technology P=Passive Infrared Voltage (2) 347V=347 Volt (8) UNV=Universal Voltage 120-277 Driver Type CD=0-10V Dimming Driver (10% - 100% Dimming) HCD=0-10V Dimming Driver (1% - 100% Dimming) SD=Step-Dim Driver (5) 5LTD=Fifth Light DALI Driver (10% - 100% Dimming) (5), (6) Options Emergency EL7W=7-watt, 120V-277V emergency battery pack Number of Drivers installed (3) 1=1 Driver EL14W=14-watt 120V-277V emergency battery pack installed (3) GTD2=Bodine Generator Transfer Device (9) ETS2=IOTA Emergency Transfer Switch (9) Options G1=Gasket, Door Frame and Housing G2=G1 plus Gasket between Lens and Door G3=G1 and G2 plus Gasketing on Mounting Surface of Fixture Trims Lamps L830=3000K L835=3500K L840=4000K Flex (4) Multiple Configurations Available Sensing Technology D=Dimming Daylight Harvesting (Closed Loop) Coverage Pattern 1= ~144 Square Feet Control Type V=Analog (0-10V) Output for Local Control (10) Packaging U=Unit Pack PALC=Job Pack, in carton ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips (1) DF-22-W=2' x 2' Drywall Frame Kit DF10P-C =Decorator Dimmer, 0-10V SF10P- =Decorator Slide Dimmer, 0-10V SK-22-WS=Field Install Surface Mount Kit, Shallow SK-22-WT=Field Install Surface Mount Kit, Tall ISHH-01=Programming Remote for Integrated Sensor ISHH-02=Personal Control Remote for Integrated Sensor NOTES: (1)An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. (2)Products also available in non-US voltages and frequencies for international markets. (3)With integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available. (4)Flex does not include dimming leads. Control leads provided by others. (5)2000, 2500 and 3100 lumen packages not available for Step-dim (SD) or Fifth Light (5LTD) driver options. (6)Must be used in conjunction with a DALI control system. For complete DALI solutions by Fifth Light visit www.eaton.com/lightingsystems (7) DesignLights Consortium™ Qualified and classified for DLC Standard (all lumen packages), refer to www.designlights.org for details. (8) 347V versions are not available with emergency options. (9) Used to transfer fixture to secondary power source for life-safety operation. When used with a dimming fixture, two devices are required to ensure control is disabled while operating under emergency power. (10) Integral sensor works only with “CD” driver and is factory prewired to the driver for stand-alone control. Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information. SH IP P ING D A T A Catalog No. 22ALNG-LD4-25 22ALNG-LD4-35 Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. Wt. 10 lbs. 10 lbs. PS519060EN 2016-03-31 2 2 ALN LE D INTEGRA TED S ENS OR The ArcLine with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The ArcLine delivers superior lighting with integrated occupancy and daylighting controls. Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the ArcLine delivers automatic ON to an energy saving light level, while ensuring lighting is turned OFF when the space is unoccupied. The integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop method. Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number: ISHH-02) provides code compliant manual raise, lower, ON, OFF control. The ArcLine with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings. H o w it w ork s: • As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level. • Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 20 minutes). • If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level. This adjustable light level is typically half of the occupied daylight level. • At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting. 100 Energy Savings Opportunities (DO) Daylight Level Light Level (DO) Daylight Level (ES) Energy Saver Light Level 0 (DU) Unoccupied Level Timeout Value Unoccupied Occupied Unoccupied Occupied Target light level default: 500 lux at 8 ft. C o ve ra ge Top View CL Coverage 4m [12 ft.] Side View 3.3m [10 ft.] 0m [0 ft.] 0m [0 ft.] 4m [12 ft.] O p t io n a l R e mote C o n tro l R Lo aise we / r 5 LO SE T MI N 75 To 50 MA X 4m [12 ft.] Reccomended Mounting Height 8–12 ft. 4m [12 ft.] Major Motion Se 1. 5 Rais t O 2. 0, 7 e, L utp o T 3. o sa 5, M we ut Se a r lec ve p x. or P re t O res ss s cc M or SET in. Un Oc c 0m [0 ft.] U Oc n c Tim Ou e t 10 HI 15 ES 20 Oc c Pr og ra mm IS ing H H Re -0 mote 1 ISHH-01 Remote Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. PS519060EN 2016-03-31