TM INSTALLATION INSTRUCTIONS IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE. General: Upon receipt of fixture thoroughly inspect for any freight damage, which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct merchandise. Entri Series and Thruway Box Sheet 1 of 6 3/15/04 IMI-573 Safety: This fixture must be wired in accordance with the National Electrical Code, applicable local codes and ordinance. Proper grounding is required to insure personal safety. Consult an electrician to ensure correct branch circuit conductor. WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing. Note: DO NOT mount HID luminaire versions directly on a combustible surface. WARNING: Risk of Burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture. APPLICATIONS: • • • • Suitable for Wet Location. Wall Mount Luminaire Only. Use lamp type suitable for this luminaire. Consult re-lamp label and lamp instructions for details. Construction is suitable for Downmount and Upmount. INSTALLATION: Standard Downmount Application - Figure 1 1. Remove the mounting plate from the fixture by loosening the two Allen head screws. 2. Loosen the lock nut from the mounting plate. 3. Detach tether from the mounting plate. 4. Mount the mounting plate to the junction box or wall with gasket away from the luminaire and secure to the structure with screws (by others). NOTE: Tether’s connection on the mounting plate must be opposite of the tether’s connection on the fixture as shown in Figure 1. 5. Re-attach tether to the mounting plate. 6. Tighten the lock nut. Fixture NOTE: Tether must be able to rotate freely; therefore, do not over tighten lock nut. Fixture must hang from the tether, NOT from electrical Mounting Lock Nut wires. Bracket Mounting Plate 7. Slide the luminaire-mounting bracket over the top lid Tether (Secure to J-Box or Wall) of the mounting plate. 8. Re-tighten the two (2) Allen head screws to secure the luminaire to the mounting plate. 9. Refer to re-lamp instructions for lamp installation. Door Latch Gasket on Back Allen Head Screws J-Box or Wall Figure 1 These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative. Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-573 AVU040024 TM INSTALLATION INSTRUCTIONS IMPORTANT: Read carefully before installing fixture. Retain for future reference. Entri Series and Thruway Box Sheet 2 of 6 3/15/04 IMI-573 WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH Standard Upmount Application - Figure 1A 1. Repeat step 1 through step 6 in Standard Downmount application. 2. Slide the luminaire-mounting bracket up and underneath the bottom lid of the mounting plate. 3. Re-tighten the two (2) Allen head screws to secure the luminaire to the mounting plate. 4. Refer to re-lamp instructions for lamp installation. Allen Head Screw Fixture Mounting Plate (Secure to J-Box or Wall) Gasket on Back Tether Mounting Bracket Lock Nut J-Box or Wall Figure 1a Thruway Box-VA2001-XX Accessories - Illustration 2a & 2b, for use in a Downmount application only Note: Unit with a thruway box weighs more than 25 pounds. Therefore, connect mounting plate to the wall using the 4 larger holes. 1. Remove the mounting plate from the back of thruway Thruway Box Cover box by loosening two (2) Allen head screws. 2. Mount the mounting plate to the wall using the Mounting Bracket four (4) larger holes with screw (by others). Donut Gasket (On Back Box) 3. Slide the thruway box mounting bracket over the lid Mounting Plate of the mounting plate. (Secure to Wall) 4. Re-tighten the two (2) Allen head screws to secure Gasket on Back the thruway box to the mounting plate. 5. If used with thru branch wiring, then remove plugs Mounting on side as required and install 3/4 NPS pipe. Screws Gasket 6. Remove the thruway box cover from thruway box 4 Larger Holes Thruway Box housing by loosening five (5) screws. Allen Head Housing Screws 7. Remove mounting plate from the back of fixture by loosening two (2) Allen head screws. Figure 2 8. Install the fixture-mounting plate on thruway box cover with four (4) screw and nuts provided. 9. Pull supply wires through center hole and re-install thruway box cover back on thruway box housing. 10.Attach the tether from the back of fixture to the mounting plate. 11.Tighten the lock nut. NOTE: Tether must be able to rotate freely; therefore, do not over tighten lock nut. 12.Slide the luminaire-mounting bracket over the top lid of the mounting plate. 13.Tighten the two (2) Allen head screws to secure the luminaire to the mounting plate. These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative. Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-573 AVU040024 TM INSTALLATION INSTRUCTIONS IMPORTANT: Read carefully before installing fixture. Retain for future reference. Entri Series and Thruway Box Sheet 3 of 6 3/15/04 IMI-573 WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH Thruway Box Housing Thruway Box Gasket 10-24 x 5/8" SST Screw 10-24 x 5/8" SST Screw Gasket on Back Hex Washer Nut Fixture Nylon Lock Nut Mounting Plate Mounting Plate (Remove from Back of Fixture) Tether Allen Head Screw Tether's Connection (Connect to the Back of Fixture) Thruway Box Unit Figure 2b Thruway Box Cover Figure 2a Thruway Box with Options - Figure 3 & 3a, for use in a Downmount application only 1. Repeat step 1 through 6 in “Thruway Box - VA2001-XX Accessories”. 2. Remove the thruway box cover from thruway box housing by loosening five (5) screws. 3. Remove the thruway box door by loosening four (4) screws. 4. Pull supply wires and re-install thruway box cover back on thruway box housing. 5. Attach the tether from the back of fixture to the mounting plate. 6. Tighten the lock nut. NOTE: Tether must be able to rotate freely; therefore, do not over tighten lock nut. 7. Plug the quick-disconnect. Mounting Plate 8. Push the wires into the thruway (Secure to Wall) box. 9. Slide the luminaire-mounting bracket over the top lid of the Mounting Plate mounting lid. 10.Tighten the two (2) Allen head Quick screws to secure the luminaire Disconnect to the mounting plate. 11.Re-install the thruway box door. Figure 3 Quick Disconnect Figure 3a These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative. Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-573 AVU040024 TM Entri Series and Thruway Box INSTALLATION INSTRUCTIONS Sheet 4 of 6 3/15/04 IMPORTANT: Read carefully before installing fixture. Retain for future reference. IMI-573 WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH Thruway Box with Options 2 - Figure 3b, for use in Downmount application only. 1. Repeat step 1 through step 6 in “Thruway Box - VA2001-XX Accessories”. 2. Remove the thruway box cover from thruway box housing by loosening five (5) screws. 3. Remove the thruway box door by loosening four (4) screws. 4. Pull the supply wires. 5. Temporarily secure the tether from the back of the fixture to the thruway box. 6. Feed the fixture’s leads through the center hole of the thruway box Mounting cover. Plate 7. Re-install thruway box cover back on thruway box housing. 8. Remove the tether from the back of fixture to the mounting plate. 9. Attach the tether from the back of fixture to the mounting plate. 10.Tighten the lock nut. NOTE: Tether must be able to rotate freely; therefore, do not over tighten lock nut. Tether 11.Push the wires into the thruway box. 12.Slide the luminaire-mounting bracket over the top lid of the mounting plate. Figure 3b 13.Plug the quick-disconnect(s). 14.Tighten the two (2) Allen head screws to secure the luminaire to the mounting plate. 15.Re-install the thruway box door. Fixture Thruway Box Cover Thruway Box Housing Quick Disconnect Thruway Box Door Wire-guard Installation (Optional) - Figure 4 & 4a NOTE: Wire-guard for use in Downmount application only. 1. Properly align wire-guard to the glass window area. 2. Mark four (4) locations to be drilled. 3. Carefully drill four (4) holes using drill size #18 on the marked areas. NOTE: Do not drill through optic, electrical components and wires. Remove optic from housing, clear electrical components and wires prior to drilling holes. 4. Secure wire-guard to the luminaire housing with the provided hardware. Wire-Guard Washer Housing Screw Screw (Secure to Housing) Glass Window Area Figure 4 O-Ring Figure 4a These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative. Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-573 AVU040024 TM Entri Series and Thruway Box INSTALLATION INSTRUCTIONS Sheet 5 of 6 3/15/04 IMPORTANT: Read carefully before installing fixture. Retain for future reference. IMI-573 WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH RE-LAMP NOTE: When installing or removing lamps, grasp lamp only by the base of the lamp, NOT BY THE GLASS. Verify the lamp matches the re-lamp label on the luminaire. For Faceplate Mounted Socket - Figure 5, 5a & 5b 1. Open the door by pulling the door latch upward as shown in Figure 5a. 2. Unplug wire at the quick-disconnect. 3. Loosen two (2) top thumbscrews. 4. Lift up faceplate mounted bracket off the reflector. 5. Remove the old lamp and replace with new one. 6. Place faceplate mounted bracket back on reflector. 7. Re-tighten two (2) top thumbscrews. 8. Re-plug the quick-disconnect. 9. Close the door and re-latch. Door Door Latch Figure 5 Lamp Lamp Faceplate Mounted Bracket Faceplate Mounting Bracket Quick Disconnect Top Thumbscrew Figure 5a Top Thumbscrew Quick Disconnect Figure 5b For Side Bracket Mounted Socket - Figure 6 & 6a 1. Repeat step 1 through step 4 in “For Faceplate Mounted Socket”. 2. Loosen side thumbscrew. 3. Pull out bracket mounted socket. 4. Remove the old lamp and replace with new one. 5. Slide the side bracket mounted socket back on reflector. 6. Re-tighten side thumbscrew. 7. Place faceplate cover back on reflector. 8. Re-tighten two (2) top thumbscrews. 9. Re-plug the quick-disconnect. 10.Close the door and re-latch. These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative. Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-573 AVU040024 TM Entri Series and Thruway Box INSTALLATION INSTRUCTIONS Sheet 6 of 6 3/15/04 IMPORTANT: Read carefully before installing fixture. Retain for future reference. IMI-573 WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH Top Thumbscrew Top Thumbscrew Faceplate Cover Faceplate Cover Optic (Reflector) Optic (Reflector) Side Thumbscrew Side Bracket Mounted Socket Side Thumbscrew Quick Disconnect Figure 6a Lamp Side Bracket Mounted Socket Figure 6 Quick Disconnect For CF-lamp(s) - Figure 7 & 7a 1. Repeat step 1 through step 4 in “For Faceplate Mounted Socket”. 2. Carefully pull out the old lamp(s) slowly. 3. Installing new lamp(s). 4. Place faceplate cover back on reflector. 5. Re-tighten two (2) top thumbscrews. 6. Re-plug the quick-disconnect. 7. Close the door and re-latch. Top Thumbscrew Faceplate Cover Top Thumbscrew Faceplate Cover Quick Disconnect Quick Disconnet Optic Optic Lamp Lamp Figure 7 Figure 7a These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative. Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-573 AVU040024