INSTALLATION INSTRUCTIONS Sheet 1 of 6 Entri Series and Thruway Box

advertisement
TM
INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.
RETAIN FOR FUTURE REFERENCE.
General: Upon receipt of fixture thoroughly inspect for any
freight damage, which should be brought to the attention of
the delivery carrier. Compare the catalog description listed
on the packing slip with the fixture label on the housing to
assure you have received the correct merchandise.
Entri Series and
Thruway Box
Sheet 1 of 6
3/15/04
IMI-573
Safety: This fixture must be wired in accordance with
the National Electrical Code, applicable local codes and
ordinance. Proper grounding is required to insure personal
safety. Consult an electrician to ensure correct branch circuit
conductor.
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
Note: DO NOT mount HID luminaire versions directly on a combustible surface.
WARNING: Risk of Burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture.
APPLICATIONS:
•
•
•
•
Suitable for Wet Location.
Wall Mount Luminaire Only.
Use lamp type suitable for this luminaire. Consult re-lamp label and lamp instructions for details.
Construction is suitable for Downmount and Upmount.
INSTALLATION:
Standard Downmount Application - Figure 1
1. Remove the mounting plate from the fixture by loosening the two Allen head screws.
2. Loosen the lock nut from the mounting plate.
3. Detach tether from the mounting plate.
4. Mount the mounting plate to the junction box or wall with gasket away from the luminaire and secure to the
structure with screws (by others).
NOTE: Tether’s connection on the mounting plate must be opposite of the tether’s connection on the fixture as
shown in Figure 1.
5. Re-attach tether to the mounting plate.
6. Tighten the lock nut.
Fixture
NOTE: Tether must be able to rotate freely; therefore,
do not over tighten lock nut. Fixture must
hang from the tether, NOT from electrical
Mounting
Lock Nut
wires.
Bracket
Mounting Plate
7. Slide the luminaire-mounting bracket over the top lid
Tether
(Secure to J-Box or Wall)
of the mounting plate.
8. Re-tighten the two (2) Allen head screws to secure
the luminaire to the mounting plate.
9. Refer to re-lamp instructions for lamp installation.
Door Latch
Gasket on
Back
Allen Head
Screws
J-Box
or Wall
Figure 1
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269
IMI-573
AVU040024
TM
INSTALLATION INSTRUCTIONS
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
Entri Series and
Thruway Box
Sheet 2 of 6
3/15/04
IMI-573
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH
Standard Upmount Application - Figure 1A
1. Repeat step 1 through step 6 in Standard Downmount application.
2. Slide the luminaire-mounting bracket up and underneath the
bottom lid of the mounting plate.
3. Re-tighten the two (2) Allen head screws to secure the luminaire
to the mounting plate.
4. Refer to re-lamp instructions for lamp installation.
Allen Head
Screw
Fixture
Mounting Plate
(Secure to J-Box
or Wall)
Gasket
on Back
Tether
Mounting
Bracket
Lock Nut
J-Box
or Wall
Figure 1a
Thruway Box-VA2001-XX Accessories - Illustration 2a & 2b, for use in a Downmount application only
Note: Unit with a thruway box weighs more than 25 pounds. Therefore, connect mounting plate to the wall using
the 4 larger holes.
1. Remove the mounting plate from the back of thruway
Thruway Box Cover
box by loosening two (2) Allen head screws.
2. Mount the mounting plate to the wall using the
Mounting
Bracket
four (4) larger holes with screw (by others).
Donut Gasket
(On Back Box)
3. Slide the thruway box mounting bracket over the lid
Mounting Plate
of the mounting plate.
(Secure to Wall)
4. Re-tighten the two (2) Allen head screws to secure
Gasket
on Back
the thruway box to the mounting plate.
5. If used with thru branch wiring, then remove plugs
Mounting
on side as required and install 3/4 NPS pipe.
Screws
Gasket
6. Remove the thruway box cover from thruway box
4 Larger Holes
Thruway Box
housing by loosening five (5) screws.
Allen Head
Housing
Screws
7. Remove mounting plate from the back of fixture by
loosening two (2) Allen head screws.
Figure 2
8. Install the fixture-mounting plate on thruway box
cover with four (4) screw and nuts provided.
9. Pull supply wires through center hole and re-install thruway box cover back on thruway box housing.
10.Attach the tether from the back of fixture to the mounting plate.
11.Tighten the lock nut.
NOTE: Tether must be able to rotate freely; therefore, do not over tighten lock nut.
12.Slide the luminaire-mounting bracket over the top lid of the mounting plate.
13.Tighten the two (2) Allen head screws to secure the luminaire to the mounting plate.
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269
IMI-573
AVU040024
TM
INSTALLATION INSTRUCTIONS
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
Entri Series and
Thruway Box
Sheet 3 of 6
3/15/04
IMI-573
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH
Thruway Box
Housing
Thruway Box
Gasket
10-24 x 5/8"
SST Screw
10-24 x 5/8"
SST Screw
Gasket
on Back
Hex Washer Nut
Fixture
Nylon Lock Nut
Mounting
Plate
Mounting Plate
(Remove from Back
of Fixture)
Tether
Allen Head
Screw
Tether's Connection
(Connect to the Back
of Fixture)
Thruway
Box Unit
Figure 2b
Thruway
Box Cover
Figure 2a
Thruway Box with Options - Figure 3 & 3a, for use in a Downmount application only
1. Repeat step 1 through 6 in “Thruway Box - VA2001-XX Accessories”.
2. Remove the thruway box cover from thruway box housing by loosening five (5) screws.
3. Remove the thruway box door by loosening four (4) screws.
4. Pull supply wires and re-install thruway box cover back on thruway box housing.
5. Attach the tether from the back of fixture to the mounting plate.
6. Tighten the lock nut.
NOTE: Tether must be able to rotate freely; therefore, do not over tighten lock nut.
7. Plug the quick-disconnect.
Mounting Plate
8. Push the wires into the thruway
(Secure to Wall)
box.
9. Slide the luminaire-mounting
bracket over the top lid of the
Mounting
Plate
mounting lid.
10.Tighten the two (2) Allen head
Quick
screws to secure the luminaire
Disconnect
to the mounting plate.
11.Re-install the thruway box door.
Figure 3
Quick
Disconnect
Figure 3a
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269
IMI-573
AVU040024
TM
Entri Series and
Thruway Box
INSTALLATION INSTRUCTIONS
Sheet 4 of 6
3/15/04
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
IMI-573
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH
Thruway Box with Options 2 - Figure 3b, for use in Downmount application only.
1. Repeat step 1 through step 6 in “Thruway Box - VA2001-XX
Accessories”.
2. Remove the thruway box cover from thruway box housing by
loosening five (5) screws.
3. Remove the thruway box door by loosening four (4) screws.
4. Pull the supply wires.
5. Temporarily secure the tether from the back of the fixture to the
thruway box.
6. Feed the fixture’s leads through the center hole of the thruway box
Mounting
cover.
Plate
7. Re-install thruway box cover back on thruway box housing.
8. Remove the tether from the back of fixture to the mounting plate.
9. Attach the tether from the back of fixture to the mounting plate.
10.Tighten the lock nut.
NOTE: Tether must be able to rotate freely; therefore, do not over
tighten lock nut.
Tether
11.Push the wires into the thruway box.
12.Slide the luminaire-mounting bracket over the top lid of the
mounting plate.
Figure 3b
13.Plug the quick-disconnect(s).
14.Tighten the two (2) Allen head screws to secure the luminaire to the mounting plate.
15.Re-install the thruway box door.
Fixture
Thruway Box
Cover
Thruway Box
Housing
Quick
Disconnect
Thruway Box
Door
Wire-guard Installation (Optional) - Figure 4 & 4a
NOTE: Wire-guard for use in Downmount application only.
1. Properly align wire-guard to the glass window area.
2. Mark four (4) locations to be drilled.
3. Carefully drill four (4) holes using drill size #18 on the marked areas.
NOTE: Do not drill through optic, electrical components and wires. Remove optic from housing, clear electrical
components and wires prior to drilling holes.
4. Secure wire-guard to the luminaire housing with the provided hardware.
Wire-Guard
Washer
Housing
Screw
Screw
(Secure to Housing)
Glass Window
Area
Figure 4
O-Ring
Figure 4a
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269
IMI-573
AVU040024
TM
Entri Series and
Thruway Box
INSTALLATION INSTRUCTIONS
Sheet 5 of 6
3/15/04
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
IMI-573
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH
RE-LAMP
NOTE: When installing or removing lamps, grasp lamp only by the base of the lamp, NOT BY THE GLASS.
Verify the lamp matches the re-lamp label on the luminaire.
For Faceplate Mounted Socket - Figure 5, 5a & 5b
1. Open the door by pulling the door latch upward as shown in Figure 5a.
2. Unplug wire at the quick-disconnect.
3. Loosen two (2) top thumbscrews.
4. Lift up faceplate mounted bracket off the reflector.
5. Remove the old lamp and replace with new one.
6. Place faceplate mounted bracket back on reflector.
7. Re-tighten two (2) top thumbscrews.
8. Re-plug the quick-disconnect.
9. Close the door and re-latch.
Door
Door Latch
Figure 5
Lamp
Lamp
Faceplate
Mounted
Bracket
Faceplate
Mounting
Bracket
Quick
Disconnect
Top
Thumbscrew
Figure 5a
Top
Thumbscrew
Quick
Disconnect
Figure 5b
For Side Bracket Mounted Socket - Figure 6 & 6a
1. Repeat step 1 through step 4 in “For Faceplate Mounted Socket”.
2. Loosen side thumbscrew.
3. Pull out bracket mounted socket.
4. Remove the old lamp and replace with new one.
5. Slide the side bracket mounted socket back on
reflector.
6. Re-tighten side thumbscrew.
7. Place faceplate cover back on reflector.
8. Re-tighten two (2) top thumbscrews.
9. Re-plug the quick-disconnect.
10.Close the door and re-latch.
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269
IMI-573
AVU040024
TM
Entri Series and
Thruway Box
INSTALLATION INSTRUCTIONS
Sheet 6 of 6
3/15/04
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
IMI-573
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH
Top
Thumbscrew
Top
Thumbscrew
Faceplate
Cover
Faceplate
Cover
Optic (Reflector)
Optic (Reflector)
Side
Thumbscrew
Side Bracket
Mounted Socket
Side
Thumbscrew
Quick
Disconnect
Figure 6a
Lamp
Side Bracket
Mounted Socket
Figure 6
Quick
Disconnect
For CF-lamp(s) - Figure 7 & 7a
1. Repeat step 1 through step 4 in “For Faceplate Mounted Socket”.
2. Carefully pull out the old lamp(s) slowly.
3. Installing new lamp(s).
4. Place faceplate cover back on reflector.
5. Re-tighten two (2) top thumbscrews.
6. Re-plug the quick-disconnect.
7. Close the door and re-latch.
Top
Thumbscrew
Faceplate
Cover
Top
Thumbscrew
Faceplate
Cover
Quick
Disconnect
Quick
Disconnet
Optic
Optic
Lamp
Lamp
Figure 7
Figure 7a
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269
IMI-573
AVU040024
Download