BRIEF PRODUCT S.T.A.R.™ Test Point Reset Type Faulted Circuit Indicators

advertisement
PRODUCT BRIEF
Cooper Power Systems
manufactures a line of Superior,
Tough And Reliable faulted circuit
indicators to fit your application.
BULLETIN B320-97034
S.T.A.R.™ Test Point Reset Type Faulted Circuit Indicators
Reliable Fault Detection in a Small, Easily Applied Package
Description:
Cooper Power Systems’ S.T.A.R. Test Point Reset (TPR) faulted circuit indicators (FCIs) can be used on
all 200 A and 600 A connectors having a voltage test point. Load levels do not effect the reset circuit. The
unit automatically resets to the normal position when circuit voltage is restored.
The remote FISHEYE™ display, with a highly reflective orange target, provides enhanced 180 degree
visibility. This unique display fits a standard remote indicator window used on padmounted
transformers. A smaller remote display is also available. Installation of the small remote display requires
only a single opening in the equipment cabinet. Without the remote display, a highly visible integral orange
fluorescent target is standard. All displays are black under normal conditions.
The selection of a TPR faulted circuit indicator has never been easier! For conventional indicators, trip
ratings are selected based on elbow voltage class, load current and minimum fault current levels. Trip
rating selection for S.T.A.R. faulted circuit indicators has been reduced to two simple choices. For a 200 A
URD circuit, select a “LO” trip rating. For a 600 A distribution system, select a “HI” trip rating. This approach
to trip selection means that one indicator fits all 15, 25 and 35 kV elbows.
With this simplified approach to rating selection:
■ Ordering is easier and faster.
■ Inventory is reduced, eliminating the need to stock multiple designs.
■ Pre-installation load surveys are not needed.
■ FCI changeouts are not necessary as systems grow.
■ Misapplication due to trip selection errors is eliminated.
For SCADA applications, auxiliary contacts (as shown above) can be added. The magnetic latching circuit
that operates the auxiliary contact ensures reliable indication.
Design Features:
These design features are standard on every S.T.A.R. faulted circuit indicator:
■ Inrush Restraint: Eliminates false tripping due to recloser operations
■ Low Pass Filter: Prevents tripping on high frequency transients
■ Temperature Compensation Circuitry: Assures accurate, reliable performance over a wide
temperature range
■ Reliable Open Core CT Design: Eliminates tripping due to adjacent magnetic fields
■ Quick Response Time: Coordinates with all current-limiting fuses
■ Tough, Durable Construction: Corrosion-proof, damage-resistant, display status cannot
mechanically change
■ Exceeds ANSI®/IEEE Standard 495-1986™
■ Quick and Easy Installation: Only one hot stick is required
PRODUCT BRIEF
S.T.A.R.™ Test Point Reset Type Faulted Circuit Indicators
Electrical
Ratings and
Characteristics:
Description
Power Requirements
Reset Time
Trip Current
Trip Accuracy
Trip Response Speed
Fault Withstand Capability
Temperature Range
Materials (Conductive EDPM Rubber)
Weight
Elbow Rating (All Manufacturers)
Auxiliary Contact Ratings
Ratings and Characteristics
Min. 5 kV L-G
Max. 3 min. at 5 kV
Factory Preset (High and Low)
+/- 10%
Response Curve, Figure 4, Sec. 320-40
25 kA for 10 cycles per ANSI®/IEEE 495-1986™
-40° C to +85° C
Corrosion-resistant & submersible per ANSI®/IEEE 495-1986™
8.56 ounces (0.24 kg)
200 & 600 A and 15, 25 & 35 kV Class
1A
30 VDC
0.5 A 125 VAC
0.3 A 110 VAC
3.4”
(87 mm)
FRONT VIEW
4.1”
(104 mm)
3.2”
(81 mm)
SIDE VIEW
CABLE LENGTH
72” (1829 mm)
1.1”
(28 mm)
TSC
2.3”
(58 mm)
6”
(153 mm)
Because we’ve incorporated so many “custom” features into our standard design, we’ve drastically reduced
the part numbers. This makes ordering easier and delivery faster. Use the diagram below to select the
S.T.A.R. Test Point Reset Type faulted circuit indicator for your application. Contact your local Cooper Power
Systems sales engineer for catalog section 320-40 and additional information.
Ordering
Information:
Standard
Digits: 1
S
2
T
Example: A Test Point Reset FCI with a high trip rating and standard 6 ft. auxiliary contact would have a
catalog number STHIA (as shown below).
Options
3
H
4
I
5
A
6
S.T.A.R. FCI Line
7
Options
Digits
FCI Type
Digit
2
T
Trip Rating
L O
Low
A
R
A
H
High
S
Digits
Type
Test Point Reset
5
3
4
I
Trip Rating
A
6
R
7
Description
Catalog No.
Adapter Kit for
Non-standard Test Points
STAK
Descriptions
*Standard Indicator with auxiliary contacts
*Standard Indicator with remote FISHEYE display
*Standard Indicator with auxiliary contacts and remote FISHEYE display
*Standard Indicator with small remote display
S
*Standard Indicator with auxiliary contacts and small remote display
* Standard Indicator with remote display and/or auxiliary contacts
provided with 6 ft. cable lengths as standard.
Notes:
1. The S.T.A.R. FCI catalog number may vary in length from 4 digits to 7 digits.
2. The standard S.T.A.R. FCI catalog number may be truncated after entering digits 1-4. Options may be selected by adding the appropriate
design code to digits 5, 6, and/or 7.
© 2006 Cooper Power Systems, Inc., or its affiliates.
S.T.A.R.™ and FISHEYE ™ are trademarks of Cooper Power Systems, Inc., or
its affiliates.
IEEE Standard 495-1986™ is a trademark of the Institute of Electrical and
Electronics Engineers.
ANSI® is a registered trademark of the American National Standards Institute.
Bulletin B320-97034 • June 2006 • Suppersedes 2/00