PRODUCT BRIEF Cooper Power Systems manufactures a line of Superior, Tough And Reliable faulted circuit indicators to fit your application. BULLETIN B320-97034 S.T.A.R.™ Test Point Reset Type Faulted Circuit Indicators Reliable Fault Detection in a Small, Easily Applied Package Description: Cooper Power Systems’ S.T.A.R. Test Point Reset (TPR) faulted circuit indicators (FCIs) can be used on all 200 A and 600 A connectors having a voltage test point. Load levels do not effect the reset circuit. The unit automatically resets to the normal position when circuit voltage is restored. The remote FISHEYE™ display, with a highly reflective orange target, provides enhanced 180 degree visibility. This unique display fits a standard remote indicator window used on padmounted transformers. A smaller remote display is also available. Installation of the small remote display requires only a single opening in the equipment cabinet. Without the remote display, a highly visible integral orange fluorescent target is standard. All displays are black under normal conditions. The selection of a TPR faulted circuit indicator has never been easier! For conventional indicators, trip ratings are selected based on elbow voltage class, load current and minimum fault current levels. Trip rating selection for S.T.A.R. faulted circuit indicators has been reduced to two simple choices. For a 200 A URD circuit, select a “LO” trip rating. For a 600 A distribution system, select a “HI” trip rating. This approach to trip selection means that one indicator fits all 15, 25 and 35 kV elbows. With this simplified approach to rating selection: ■ Ordering is easier and faster. ■ Inventory is reduced, eliminating the need to stock multiple designs. ■ Pre-installation load surveys are not needed. ■ FCI changeouts are not necessary as systems grow. ■ Misapplication due to trip selection errors is eliminated. For SCADA applications, auxiliary contacts (as shown above) can be added. The magnetic latching circuit that operates the auxiliary contact ensures reliable indication. Design Features: These design features are standard on every S.T.A.R. faulted circuit indicator: ■ Inrush Restraint: Eliminates false tripping due to recloser operations ■ Low Pass Filter: Prevents tripping on high frequency transients ■ Temperature Compensation Circuitry: Assures accurate, reliable performance over a wide temperature range ■ Reliable Open Core CT Design: Eliminates tripping due to adjacent magnetic fields ■ Quick Response Time: Coordinates with all current-limiting fuses ■ Tough, Durable Construction: Corrosion-proof, damage-resistant, display status cannot mechanically change ■ Exceeds ANSI®/IEEE Standard 495-1986™ ■ Quick and Easy Installation: Only one hot stick is required PRODUCT BRIEF S.T.A.R.™ Test Point Reset Type Faulted Circuit Indicators Electrical Ratings and Characteristics: Description Power Requirements Reset Time Trip Current Trip Accuracy Trip Response Speed Fault Withstand Capability Temperature Range Materials (Conductive EDPM Rubber) Weight Elbow Rating (All Manufacturers) Auxiliary Contact Ratings Ratings and Characteristics Min. 5 kV L-G Max. 3 min. at 5 kV Factory Preset (High and Low) +/- 10% Response Curve, Figure 4, Sec. 320-40 25 kA for 10 cycles per ANSI®/IEEE 495-1986™ -40° C to +85° C Corrosion-resistant & submersible per ANSI®/IEEE 495-1986™ 8.56 ounces (0.24 kg) 200 & 600 A and 15, 25 & 35 kV Class 1A 30 VDC 0.5 A 125 VAC 0.3 A 110 VAC 3.4” (87 mm) FRONT VIEW 4.1” (104 mm) 3.2” (81 mm) SIDE VIEW CABLE LENGTH 72” (1829 mm) 1.1” (28 mm) TSC 2.3” (58 mm) 6” (153 mm) Because we’ve incorporated so many “custom” features into our standard design, we’ve drastically reduced the part numbers. This makes ordering easier and delivery faster. Use the diagram below to select the S.T.A.R. Test Point Reset Type faulted circuit indicator for your application. Contact your local Cooper Power Systems sales engineer for catalog section 320-40 and additional information. Ordering Information: Standard Digits: 1 S 2 T Example: A Test Point Reset FCI with a high trip rating and standard 6 ft. auxiliary contact would have a catalog number STHIA (as shown below). Options 3 H 4 I 5 A 6 S.T.A.R. FCI Line 7 Options Digits FCI Type Digit 2 T Trip Rating L O Low A R A H High S Digits Type Test Point Reset 5 3 4 I Trip Rating A 6 R 7 Description Catalog No. Adapter Kit for Non-standard Test Points STAK Descriptions *Standard Indicator with auxiliary contacts *Standard Indicator with remote FISHEYE display *Standard Indicator with auxiliary contacts and remote FISHEYE display *Standard Indicator with small remote display S *Standard Indicator with auxiliary contacts and small remote display * Standard Indicator with remote display and/or auxiliary contacts provided with 6 ft. cable lengths as standard. Notes: 1. The S.T.A.R. FCI catalog number may vary in length from 4 digits to 7 digits. 2. The standard S.T.A.R. FCI catalog number may be truncated after entering digits 1-4. Options may be selected by adding the appropriate design code to digits 5, 6, and/or 7. © 2006 Cooper Power Systems, Inc., or its affiliates. S.T.A.R.™ and FISHEYE ™ are trademarks of Cooper Power Systems, Inc., or its affiliates. IEEE Standard 495-1986™ is a trademark of the Institute of Electrical and Electronics Engineers. ANSI® is a registered trademark of the American National Standards Institute. Bulletin B320-97034 • June 2006 • Suppersedes 2/00 1045 Hickory Street Pewaukee, WI 53072 USA www.cooperpower.com