Reclosers Reference Information Kyle Form 4C Recloser Control Serial Communications ® R280-90-16 DNP3 Device Profile Device Profile Template Data Dictionary Release 2.0 January 30, 2001 For Use With Cooper Power Systems Form 4C Recloser Controls December 2003 • Supersedes 10/01 Printed in USA Contents INTRODUCTION ................................................................................................................................3 DATA DICTIONARY OVERVIEW........................................................................................................4 DNP RELATED CONFIGURATION PARAMETERS...........................................................................13 DNP ERROR INDICATIONS .............................................................................................................16 REFERENCES................................................................................................................................. 18 APPENDIX A: F4C DNP 3.0 DEVICE PROFILE TEMPLATE...............................................................19 APPENDIX B: F4C DNP 3.0 DATA DICTIONARY...............................................................................24 2 Introduction The F4C Recloser Control is available with the DNP 3.0 communication protocol the “realtime”serial port. This document provides details for users that need to interface to the control using this protocol. The document is divided into sections that give an overview of the data dictionary for the control, describe configuration parameters to get started communicating, error indication definitions, and reference documents. Appendices provide the DNP 3.0 Device Profile Template filled out for the F4C control and the data dictionary for accessing the control. Unsolicited Report by Exception can be configured as either “supported” or “unsupported” via a configuration parameter. If supported, upon device reset a null unsolicited message is sent. No further unsolicited messages will be sent until a DNP messages to enable unsolicited operation is received by the control. Data link and Application retries and timeouts are configurable. See the section DNP Related Configuration Parameters for more detail. F4C Communications Introduction ∞ 3 Data Dictionary Overview Appendix B contains a listing of the data dictionary for the F4C Recloser Control. This section discusses items of interest from the data dictionary. Class 0 and 1 Binary Inputs 1. All binary input events are fixed as Class 1 data. 2. Event data is updated immediately on every change. Class 0 through 3 Counters 1. When an incoming request specifies 32-bit counters, only the lower 16 bits of the counters will be meaningful. 2. Event data is updated on a 1 second basis. Class 0 through 3 Analog Inputs 1. The data dictionary section that describes the analogs includes scale factors (for 16 bit variation) and units to translate the raw data. 2. Event data is updated on a 1 second basis. Control Relay Output Block (CROB) 1. The data dictionary CROB section indicates whether the control point is pulsed or latched. 2. The section also specifies the default condition of a point on powerup or reset. 3. Points may only be controlled using SBO as shown on the table. File ID objects in general 1. Internal objects (records) consist of static read-only data, live read-only data, configuration parameters, pseudo registers (drag-hands) and time-tagged data. 2. All data records are low byte - high byte (Big Endian) format. 3. “File Name” column in section is the ASCII file ID for accessing data and any required arguments. 4. The only allowed operations on the records are read, response or write (where appropriate). 5. Individual records may be read or written. 6. Status of the last file write operation is found in the read-only file ERR. This file is automatically over written with the status of the most recent write ACK information. File ID, Static Data 1. See the F4C product data specification for more detail on the meaning of the data objects. File ID, Dynamic Data F4C Communications Data Dictionary Overview ∞ 4 1. See the F4C product data specification for more detail on the meaning of the data objects. File ID, Configuration Data 1. See the F4C product data specification for more detail on the meaning of the data objects. 2. ACK/NAK codes are described in TBD. File ID, Pseudo Registers 1. See the F4C product data specification for more detail on the meaning of the data objects. 2. Writes to these records ignore the data that is “written” to the record. The present value of the associated live data is actually written. File ID, Time-tagged 1. See the F4C product data specification for more detail on the meaning of the data objects. 2. A variable number of records starting with the next available record are returned when all time-tagged data is requested. Additionally, each record is a variable size depending on the type of time-tagged record. The first requested record must be “0”. F4C Communications Data Dictionary Overview ∞ 5 OBJECT Obj Var Description REQUEST RESPONSE (DNP message components parsed by the CL4C/5 Series) (DNP message components reported by the CL4C/5 Series) Func Codes (dec) Qual Codes Func Codes (dec) Qual Codes (hex) (hex) 1 0 Binary Input - All Variations 1 00,01,0 6 1 1 Binary Input 1 00,01,0 6 129 00,01 1 2 Binary Input with Status 1 00,01,0 6 129 00,01 2 0 Binary Input Change - All Variations 1 06,07,0 8 2 1 Binary Input Change without Time 1 06,07,0 8 129,13 0 17, 28 2 2 Binary Input Change with Time 1 06,07,0 8 129 17, 28 2 3 Binary Input Change with Relative Time 10 0 Binary Output - All Variations 1 00,01,0 6 10 1 Binary Output 1 00,01,0 6 129 00, 01 10 2 Binary Output Status 1 00,01,0 6 129 00, 01 12 0 Control Block - All Variations 12 1 Control Relay Output Block 3,4,5,6 17, 28 129 echo of request 12 2 Pattern Control Block 12 3 Pattern Mask 20 0 Binary Counter - All Variations 1, 7, 8, 9,10 00,01,0 6 20 1 32-Bit Binary Counter 1, 7, 8, 9,10 00,01,0 6 129 00, 01 20 2 16-Bit Binary Counter 1, 7, 8, 9,10 00,01,0 6 129 00, 01 20 3 32-Bit Delta Counter 20 4 16-Bit Delta Counter 20 5 32-Bit Binary Counter without Flag 1, 7, 8, 00,01,0 129 00, 01 6 OBJECT Obj Var Description REQUEST RESPONSE (DNP message components parsed by the CL4C/5 Series) (DNP message components reported by the CL4C/5 Series) Func Codes (dec) Qual Codes Func Codes (dec) Qual Codes (hex) (hex) 9,10 6 1, 7, 8, 9,10 00,01,0 6 20 6 16-Bit Binary Counter without Flag 129 00, 01 20 7 32-Bit Delta Counter without Flag 20 8 16-Bit Delta Counter without Flag 21 0 Frozen Counter - All Variations 1 00,01,0 6 21 1 32-Bit Frozen Counter 1 00,01,0 6 129 00,01 21 2 16-Bit Frozen Counter 1 00,01,0 6 129 00,01 21 3 32-Bit Frozen Delta Counter 21 4 16-Bit Frozen Delta Counter 21 5 32-Bit Frozen Counter with Time of Freeze 21 6 16-Bit Frozen Counter with Time of Freeze 21 7 32-Bit Frozen Delta Counter with Time of Freeze 21 8 16-Bit Frozen Delta Counter with Time of Freeze 21 9 32-Bit Frozen Counter without Flag 1 00,01,0 6 129 00, 01 21 10 16-Bit Frozen Counter without Flag 1 00,01,0 6 129 00, 01 21 11 32-Bit Frozen Delta Counter without Flag 21 12 16-Bit Frozen Delta Counter without Flag 22 0 Counter Change Event - All Variations 1 06,07,0 8 22 1 32-Bit Counter Change Event without Time 1 06,07,0 8 129,13 0 17, 28 22 2 16-Bit Counter Change Event 1 06,07,0 129 17, 28 7 OBJECT Obj Var Description REQUEST RESPONSE (DNP message components parsed by the CL4C/5 Series) (DNP message components reported by the CL4C/5 Series) Func Codes (dec) Qual Codes Func Codes (dec) Qual Codes (hex) (hex) without Time 8 22 3 32-Bit Delta Counter Change Event without Time 22 4 16-Bit Delta Counter Change Event without Time 22 5 32-Bit Counter Change Event with Time 22 6 16-Bit Counter Change Event with Time 22 7 32-Bit Delta Counter Change Event with Time 22 8 16-Bit Delta Counter Change Event with Time 23 0 Frozen Counter Event - All Variations 23 1 32-Bit Frozen Counter Event without Time 23 2 16-Bit Frozen Counter Event without Time 23 3 32-Bit Frozen Delta Counter Event without Time 23 4 16-Bit Frozen Delta Counter Event without Time 23 5 32-Bit Frozen Counter Event with Time 23 6 16-Bit Frozen Counter Event with Time 23 7 32-Bit Frozen Delta Counter Event with Time 23 8 16-Bit Frozen Delta Counter Event with Time 30 0 Analog Input - All Variations 30 1 32-Bit Analog Input 30 2 16-Bit Analog Input 8 1 00,01,0 6 1 00,01,0 6 129 00,01 OBJECT Obj Var Description REQUEST RESPONSE (DNP message components parsed by the CL4C/5 Series) (DNP message components reported by the CL4C/5 Series) Func Codes (dec) Qual Codes Func Codes (dec) Qual Codes (hex) (hex) 30 3 32-Bit Analog Input without Flag 30 4 16-Bit Analog Input without Flag 30 5? 32-Bit Floating Point Analog Input 30 8? 32-Bit Floating Point Analog Input without Flag 31 0 Frozen Analog Input - All Variations 31 1 32-Bit Frozen Analog Input 31 2 16-Bit Frozen Analog Input 31 3 32-Bit Frozen Analog Input with Time of Freeze 31 4 16-Bit Frozen Analog Input with Time of Freeze 31 5 32-Bit Frozen Analog Input without Flag 31 6 16-Bit Frozen Analog Input without Flag 32 0 Analog Change Event - All Variations 32 1 32-Bit Analog Change Event without Time 32 2 16-Bit Analog Change Event without Time 32 3 32-Bit Analog Change Event with Time 32 4 16-Bit Analog Change Event with Time 32 5? 32-Bit Floating Point Analog Input 32 8? 32-Bit Floating Point Analog Input without Flag 33 0 Frozen Analog Event - All Variations 33 1 32-Bit Frozen Analog Event without Time 9 1 00,01,0 6 1 06,07,0 8 1 06,07,0 8 129 00,01 129,13 0 17, 28 OBJECT Obj Var Description REQUEST RESPONSE (DNP message components parsed by the CL4C/5 Series) (DNP message components reported by the CL4C/5 Series) Func Codes (dec) Qual Codes Func Codes (dec) Qual Codes (hex) (hex) 33 2 16-Bit Frozen Analog Event without Time 33 3 32-Bit Frozen Analog Event with Time 33 4 16-Bit Frozen Analog Event with Time 34 1 16-bit Analog Change Deadband 1 2 06, 07,08 129 17, 28 129 17, 28 40 0 Analog Output Status - All Variations 1 00,01,0 6 40 1 32-Bit Analog Output Status 1 00,01,0 6 129 00, 01 40 2 16-Bit Analog Output Status 1 00,01,0 6 129 00, 01 41 0 Analog Output Block - All Variations 41 1 32-Bit Analog Output Block 3,4,5,6 17,28 129 Echo of reques t 41 2 16-Bit Analog Output Block 3,4,5,6 17,28 129 Echo of reques t 10 50 0 Time and Date - All Variations 50 1 Time and Date 1 2 50 2 Time and Date with Interval 51 0 Time and Date CTO - All Variations 51 1 Time and Date CTO 51 2 Unsynchronized Time and Date CTO 52 0 Time Delay - All Variations 07 where quantity = 1 129 07 where quantity = 1 129 07 where quantity =1 129 echo of request 07 where quantity =1 52 1 Time Delay Coarse 129 07 where quantity =1 52 2 Time Delay Fine 129 07 where quantity =1 60 0 60 1 Class 0 Data 60 2 Class 1 Data 1 06 1 06,07,0 8 20, 21 06 60 3 Class 2 Data 1 20, 21 06,07,0 8 06 60 4 Class 3 Data 1 20, 21 06,07,0 8 06 70 1 File Identifier 1, 2 11 5B 129 5B 80 1 Internal Indications 2 00 index= 7 81 1 Storage Object 82 1 Device Profile 83 1 Private Registration Object 83 2 Private Registration Object Descriptor 90 1 Application Identifier 100 1 Short Floating Point 100 2 Long Floating Point 100 3 Extended Floating Point 101 1 Small Packed Binary-Coded Decimal 101 2 Medium Packed Binary-Coded Decimal 101 3 Large Packed Binary-Coded Decimal No object (Cold Restart) 13 129 No object (Delay Measurement) 23 129 12 2 0 – 65534 20–4 2 0 – 65535 2 0 – 65535 20–2 2 0 – 10 2 1 – 500 2 1 – 500 Remote IED Address Handshake Mode Transmit enable delay Transmit disable delay Data link confirm mode Number of data link retries for confirm Data link confirm timeout Application confirm timeout 100 100 3 0 (Never) 0 0 0 (Normal) 1 1234 50 9600 Default DNP Related Configuration Parameters ∞ 13 2 0 – 65534 Report-by-Exception (Master) Address F4C Communications 2 0 – 65535 Dead line sync Range 2 300 – 19200 (in bytes) Size Baud rate Item name For DNP implementations, the communication programming values are: DNP Related Configuration Parameters CTS ignored/RTS Asserted RTS/CTS CTS ignored/ RTS is “transmit enable” XON/XOFF software flow control 1. 2. 3. 4. Application layer retry timeout period from. Units are 10’s of milliseconds Data link retry timeout period. Units are 10’s of milliseconds Number of data link layer retries 2. Always 1. Sometimes (When multi frame messages are sent) 0. Never Code to determine when the IED will request data link ACKs from master: Time to wait after data transmission to disable transmit enable signal. (in milliseconds) Time to wait after transmit enable signal to start of data transmission. (in milliseconds) NONE 0. Code for method of controlling handshake lines: Address of this IED, i.e. this port of this control in the DNP network Destination address of unsolicited report by exception info Time for synchronizing to start of message. (in milliseconds) Serial port speed (BPS) Description 2 0 – 36000 2 0 (False), Unsolicited response notification delay Unsolicited responses supported 2 0 - 65535 2 0 – 65535 2 0 (False), Back-off Increment On Timeout Absolute Max Back-off Time Flush Events After Attempts Exhausted F4C Communications Channel Timeout Back-off Terminates On Any Message Back-off Terminates On 'Enable USR' 2 0 – 65535 Back-off terminates after time period 0 1 (True) 1 (True) 0 (False) 3600 0 60 3 0 (False) 1500 10 0 Default DNP Related Configuration Parameters ∞ 14 2 0 – 65535 1 (True) 2 0 (False), 1 (True) 2 0 (False), 1 (True) 2 0 - 9999 Delivery attempts before back off 1 (True) 2 1 – 255 Unsolicited response minimum quantity per class Range 2 0 – 10 (in bytes) Size Application Layer Retries Item name The time delay to wait for the channel to be ready, ie time from when device asserts RTS to when CTS is asserted by the DCE. Units are 10’s of milliseconds. 0 indicates infinite time delay. Bool to enable receipt of any valid message from a master (with the same address as the configured report by exception address in the device) to reset the unsolicited response back-off timer. Bool to enable receipt of “enable USR” message from a master (with the same address as the configured report by exception address in the device) to reset the unsolicited response back-off timer. Note: If “Flush events after attempts Exhausted” is set to YES, the “Delivery attempts before back off” setting effectively becomes the number of attempt cycles (including application & data link layer retries) that the device will make to transmit the USR before abandoning all attempts to send the USR and flushing the event from the device’s event buffer. Bool to delete current events from the unsolicited response buffer – ie no further unsolicited responses will be generated until new events (that would cause an unsolicited response to be generated) are created. The capped maximum period of unsolicited response back-off period that can be incremented – ie successive increments of the unsolicited response backoff period will be capped to this value. Units are seconds. The amount of time the unsolicited response back-off period increments each time following failed unsolicited response transmission cause the device to reenter back-off mode. Units are seconds. The initial unsolicited response back off period for the device to wait before recommencing transmission attempts of unsolicited responses. Units are seconds. Refer also to “Flush events after attempts Exhausted”. The consecutive number of times the application layer will send unsolicited responses without the correct acknowledgement from the master before commencing an unsolicited response back-off time-out period. 0 indicates unsolicited response back-off mode will never commence. Bool to enable support of unsolicited response operation (0 = use minimum number of events only) Maximum time after an event occurs to generate an unsolicited response. Units are 10’s of milliseconds. Minimum number of events in any class that will immediately generate an unsolicited response The number of times the application layer will retry sending a message which it previously sent and had no reply to. 0 indicates infinite retries Description 2 0 –65535 2 0 (False), Modem RX Idle Disconnect Time Out Allow obsolete 0x1B qualifier for files F4C Communications 2 0 –65535 Modem TX Idle Disconnect Time Out 0 (False) 3 3 60 ATZ 255 0 0 0 5000 Default DNP Related Configuration Parameters ∞ 15 1 (True) 2 0 to 60000 Modem Connect Time Out 12 2 0 – 255 Hang up time Modem Dial String 20–7 Collision Avoidance Channel Busy Indicator 25 2 0 – 6000 Maximum random delay Modem Initialisation string 2 0 – 60000 Fixed Delay Range 2 0 to 65535 (in bytes) Size Arm / Execute Delay Item name DCD Asserted (On) DCD Unasserted (Off) CTS Asserted (On) CTS Unasserted (Off) DSR Asserted (On) DSR Unasserted (Off) PSTN (software - Hayes character string indication) 1 2 3 4 5 6 7 Bool to enable support of 0x1B qualifier for file transfers. Provides backward compatibility with master that is not compliant with DNP Users Group technical bulletin TB9905-001. The device will disconnect a dial up session if the device does not receive any packets for a period longer than the Modem RX idel disconnect timeout. The device will disconnect the dial up call if the device does not transmit any packets for a period longer than the Modem Tx idle disconnect timeout. Maximum time for modem to return CONNECT Units are in sec. Hayes command to dial out (dial up only) Hayes commands to initialize modem (dial up only) A device which has not transmitted or received any packets I the last period of time (hang up time) will terminate the connection. Never Busy 0 Code to determine which RS232 control line to use to indicate channel is busy. Maximum collision avoidance hold-off time Fixed collision avoidance delay Units are in milliseconds. Maximum time between receiving Arm command and receiving corresponding Execute command for the command to be carried out. Description DNP Error Indications The Internal Indications (IIN) bits from Section 3.6 of the DNP 3.0 Application Layer document are defined as follows: 1st Octet Bit 0 All stations message received. As defined Section 3.6. Bit 1 Class 1 data available. As defined Section 3.6. Bit 2 Class 2 data available. As Defined in Section 3.6. Bit 3 Class 3 data available. Not used. Device has no Class 3 data. Bit 4 Time sync required from master. As defined Section 3.6. Bit 5 Outstation is in local. As defined Section 3.6 for CROB points. Configuration Parameters are not writeable when the outstation is in local. Bit 6 Device Trouble. As defined by Custom Logic for this control. Bit 7 Device restart. As defined Section 3.6. F4C Communications DNP Error Indications ∞ 16 2nd Octet Bit 0 Function code not implemented. As defined Section 3.6. Bit 1 Requested objects unknown. As defined Section 3.6. Bit 2 Parameters in the qualifier, range or data fields are invalid or out of range. As defined Section 3.6. Writes to Configuration Parameters will set this bit to indicate that data could not be written. The file ERR must be read to determine the cause of failure. Bit 3 Event buffer overflow. Not used. Bit 4 Request understood but already executing.. As defined Section 3.6. Bit 5 Current configuration is corrupted. Not used. Bit 6 Reserved. Bit 7 Reserved. F4C Communications DNP Error Indications ∞ 17 References DNP 3.00 Basic 4, Rev. 01 DNP V30.00 Subset Definitions, Version 1.00 DNP Control Relay Output Block Minimum Implementation, 3/8/96 F4C Recloser Control Product Data - DATA 2163 F4C Communications References ∞ 18 Appendix A: F4C DNP 3.0 Device Profile Template F4C Communications Appendix A: F4C DNP 3.0 Device Profile Template Page 19 ∞ DNP V3.00 DEVICE PROFILE DOCUMENT This document must be accompanied by a table having the following headings: Object Group Request Function Codes Response Function Codes Object Variation Request Qualifiers Response Qualifiers Object Name (optional) Vendor Name: Cooper Power Systems Device Name: 6A00042501 Protocol Converter for F4C Recloser Control Highest DNP Level Supported: For Requests 2 Device Function: Master Slave For Responses 2 Notable objects, functions, and/or qualifiers supported in addition to the Highest DNP Levels Supported (the complete list is described in the attached table): Device uses File Identifier (Obj. 70 Var. 01) to access Read-only static & live data, configuration data, pseudo registers and time-tagged data. Explanations for items that are configurable may be found in the DNP Related Configuration Parameters in this document. Analog deadband parameters are stored in non-volatile memory and will be retained on reset Binary Frozen Counters are not returned in Class 0 response. Maximum Data Link Frame Size (octets): Maximum Application Fragment Size (octets): Transmitted 292 Transmitted 2048 Received 292 Received Maximum Data Link Re-tries: None Fixed at Configurable, range None to 10 30-Jan-01 R280-90-16 Page 20 2048 Maximum Application Layer Re-tries: None Configurable, range None to 10 (Fixed is not permitted) Appendix A Page 1 of 4 Rev 2.0 Requires Data Link Layer Confirmation: Never Always Sometimes If 'Sometimes', when? ______________________________________________ Configurable If 'Configurable', how?___Via Item in configuration parameters ____ Requires Application Layer Confirmation: Never Always (not recommended) When reporting Event Data (Slave devices only) When sending multi-fragment responses (Slave devices only) Sometimes If 'Sometimes', when? ______________________________________________ Configurable If 'Configurable', how?______________________________________________ Timeouts while waiting for: Data Link Confirm None None Complete Appl. Fragment Configurable None Application Confirm Configurable None Complete Appl. Response Configurable Fixed at _________ Variable Configurable Fixed at _________ Variable Fixed at _________ Variable Fixed at _________ Variable Others ________________________________________________________________________ __ Attach explanation if 'Variable' or 'Configurable' was checked for any timeout Sends/Executes Control Operations: WRITE Binary Outputs Never SELECT/OPERATE Never Never DIRECT OPERATE DIRECT OPERATE – NO ACK Never Count > 1 Pulse On Pulse Off Latch On Always Sometimes Always Sometimes Always Sometimes Always Sometimes Configurable Configurable Configurable Configurable Never Always Sometimes Configurable Never Always Sometimes Configurable Never Always Sometimes Configurable Never Always Sometimes Configurable R280-90-16 Page 21 Appendix A Page 2 of 4 Latch Off Never Always Sometimes Configurable Queue Clear Queue Never Always Sometimes Configurable Never Always Sometimes Configurable Attach explanation if 'Sometimes' or 'Configurable' was checked for any operation. R280-90-16 Page 22 Appendix A Page 3 of 4 FILL OUT THE FOLLOWING ITEM FOR MASTER DEVICES ONLY: Expects Binary Input Change Events: Either time-tagged or non-time-tagged for a single event Both time-tagged and non-time-tagged for a single event Configurable (attach explanation) FILL OUT THE FOLLOWING ITEMS FOR SLAVE DEVICES ONLY: Reports Binary Input Change Events when no specific variation requested: Never Only time-tagged Only non-time-tagged Configurable to send both, one or the other (attach explanation) Sends Unsolicited Responses: Never Configurable (attach explanation) Only certain objects Sometimes (attach explanation) Reports time-tagged Binary Input Change Events when no specific variation requested: Time Never Binary Input Change With Time Binary Input Change With Relative Configurable (attach explanation) Sends Static Data in Unsolicited Responses: Never When Device Restarts When Status Flags Change No other options are permitted. ENABLE/DISABLE UNSOLICITED Function codes supported Default Counter Object/Variation: No Counters Reported Configurable (attach explanation) Default Object 20 Default Variation 06 Point-by-point list attached Counters Roll Over at: No Counters Reported Configurable (attach explanation) 16 Bits 32 Bits Other Value __________ Point-by-point list attached Sends Multi-Fragment Responses: Yes No R280-90-16 Page 23 Appendix A Page 4 of 4 Appendix B: F4C DNP 3.0 Data Dictionary F4C Communications Appendix B: F4C DNP 3.0 Data Dictionary Page 24 ∞ 30-Jan-01 29-Jan-01 16-May-00 29-Jan-00 30-Oct-99 1-Sep-99 v 2.0 v 0.7 v 0.6 v 0.5c v 0.5b v 0.5 30-Jan-01 R280-90-16 Page 25 Updated Firmware to Version 2.12 DNP3.0 L2 Compliant Removed Object 2 descriptions from Object 1 Indices 96-105 Changed: Obj 12 Index 26 to Latched; Obj 22 Variation to 2 Updated PCCFG file to V2.12 firmware release Added CROB for transparent mode & updated PCCFG file Corrected Counters and added Status of CROB to Class 0 Appendix B Page 1 of 9 THE INFORMATION CONTAINED IN THIS DOCUMENT IS THE PROPERTY OF COOPER INDUSTRIES, INC. UNAUTHORIZED REPRODUCTION OR MODIFICATION IS PROHIBITED. F4C DNP 3.0 Protocol Device Profile Data Dictionary F4C DNP 3.0 Device Profile data dictionary 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input R280-90-16 Page 26 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Index Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Description INPUT SUBSYSTEM 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status Default Static Variation Obj Var Desc 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Appendix B Page 2 of 9 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Default Event Variation Obj Var Class Desc Seq No 30, Bit xx 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Seq No 31, Bit xx 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Seq No 32, Bit xx 00 01 02 03 04 05 Combined Recloser Status Recloser tripped Recloser Lockout Malfunction Battery Not OK Recloser closed Current above minimum trip Accessory operation AC power OK Supervisory allowed Power status OK Alternate minimum trip active Ground trip block actve Non-reclose active Event data available SGF active/available Not used Combined Internal Control Status - Part 1 Power down active Sequence co-ordinaton allowed Target reset on successful reclose Trip counter on/off Event recorder on/off Interrupter monitor on/off Phase complex TCC 1 on/off Ground complex TCC 1 on/off Phase complex TCC 2 on/off Ground complex TCC 2 on/off Phase high current trip on/off Ground high current trip on/off Phase high current lockout on/off Ground high current lockout on/off Ground trip precedence on/off Momentary relay operation on/off Target Recorder Status Ground Phase A Phase B Phase C SGF Not used Class 0 - 3, Binarys Cooper 2180 Cross Reference Comments F4C DNP 3.0 Device Profile data dictionary 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input R280-90-16 Page 27 Index 38 39 40 41 42 43 44 45 46 47 Description Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status Default Static Variation Obj Var Desc 01 01 No Status 01 01 No Status 01 01 No Status 01 01 No Status 01 01 No Status 01 01 No Status 01 01 No Status 01 01 No Status 01 01 No Status 01 01 No Status 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Appendix B Page 3 of 9 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Default Event Variation Obj Var Class Desc 02 01 1 Without Time 02 01 1 Without Time 02 01 1 Without Time 02 01 1 Without Time 02 01 1 Without Time 02 01 1 Without Time 02 01 1 Without Time 02 01 1 Without Time 02 01 1 Without Time 02 01 1 Without Time Seq No 33, Bit xx 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Seq No 34, Bit xx 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Accessory Operation Code High Current lockout Remote trip and lockout Supervisory trip and lockout Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Malfunction Status Code Failed to close on remote Failed to close on local Low battery voltage Power down in less than programmed time Defective data in EEROM Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Class 0 - 3, Binarys Cooper 2180 Cross Reference 06 07 08 09 10 11 12 13 14 15 Comments Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used F4C DNP 3.0 Device Profile data dictionary 96 97 98 99 100 101 102 103 104 105 Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input R280-90-16 Page 28 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 Index Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Binary Input Description 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status No Status Default Static Variation Obj Var Desc 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Without Time Appendix B Page 4 of 9 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Default Event Variation Obj Var Class Desc Class 0 - 3, Binarys Seq No 35, Bit xx 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Combined Internal Control Status - Part 2 SGF enable Not used Not used Not used Not used Not used Not used Not used SGF tripping on/off Hot line tag active Tripping on TCC 2 only on/off UDP switch mode on/off LTC disable output active Not used Not used Not used Protocol Converter Status DIP/Rotary switch override on Terminal configuration on Protocol converter running ROM error RAM error Not Used Control unit responding Not Used Not Used Invalid protocol convertor real time clock Cooper 2180 Cross Reference Comments F4C DNP 3.0 Device Profile data dictionary 06 07 08 09 10 11 Binary Counter Binary Counter Binary Counter Binary Counter Binary Counter Binary Counter R280-90-16 Page 29 00 01 02 03 04 05 Index Binary Counter Binary Counter Binary Counter Binary Counter Binary Counter Binary Counter Description INPUT SUBSYSTEM 20 20 20 20 20 20 06 06 06 06 06 06 Default Static Variation Obj Var Desc 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 22 22 22 22 22 22 02 02 02 02 02 02 Without Flag Without Flag Without Flag Without Flag Without Flag Without Flag Appendix B Page 5 of 9 1 1 1 1 1 1 Default Event Variation Obj Var Class Desc Protocol Converter Counters Comms Tx Comms Rx Comms Rx Errors Control Tx Control Rx Control Rx Errors Switch operation counters Number of ground OCP targets Number of phase 1-2 OCP targets Number of phase 3-4 OCP targets Number of phase 5-6 OCP targets Switch operation counter Number of SGF OCP targets Comments F4C DNP 3.0 Device Profile data dictionary 40 41 42 43 44 45 Class 0 - 3, Counters Cooper 2180 Cross Reference Seq No xx 02 03 04 05 06 07 08 09 10 Analog Input Analog Input Analog Input Analog Input Analog Input Analog Input Analog Input Analog Input Analog Input R280-90-16 Page 30 00 01 Index Analog Input Analog Input Description INPUT SUBSYSTEM 30 30 30 30 30 30 30 30 30 30 30 02 02 02 02 02 02 02 02 02 02 02 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit Default Static Variation Obj Var Desc 34 34 34 34 34 34 34 34 34 34 34 01 01 01 01 01 01 01 01 01 01 01 Obj Var Desc 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit 32 32 32 32 32 32 32 32 32 32 32 02 02 02 02 02 02 02 02 02 02 02 Without Flag Without Flag Without Flag Without Flag Without Flag Without Flag Without Flag Without Flag Demand ground current Demand current through bushing 1-2 Demand current through bushing 3-4 Demand current through bushing 5-6 Instantaneous current values Instantaneous ground current Instantaneous current through bushing 1-2 Instantaneous current through bushing 3-4 Instantaneous current through bushing 5-6 Without Flag Sequence position Calibration references Without Flag Calibration reference 90% (fixed at 29491) Without Flag Calibration reference 0 (fixed at 0) Comments Appendix B Page 6 of 9 2 2 2 2 2 2 2 2 2 2 2 Default Deadband VariationDefault Event Variation Obj Var Class Desc F4C DNP 3.0 Device Profile data dictionary 87 88 89 8A 83 84 85 86 82 80 81 Cooper 2180 Cross Reference Seq No xx Amps Amps Amps Amps Amps Amps Amps Amps Units Class 0 - 3, Analogs 1 1 1 1 1 1 1 1 1 1 1 Multiplication Scale Factor R280-90-16 Page 31 00 10 Binary Output 12 12 12 31 32 33 Binary Output Binary Output Binary Output 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 2 Status 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Obj Var Desc 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Index Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Binary Output Description CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB CROB Default Static Variation Off Off Off Off Off Off On On Off Off On Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Protocol Converter control * Perform Operation -trip & lockout Protocol Converter control Restart protocol converter Load protocol converter defaults Force transparent mode Perform Operation -trip & lockout Perform Operation -trip Perform Operation - close Alternate minimum trip on/off Ground trip block on/off Non-reclose on/off Power-down on/off Sequence co-ordination on/off Target reset on successful reclose on/off Operation counter on/off Event recorder on/off Interrrupter duty on/off Complex TCC #1 , Phase on/off Complex TCC #1 , Ground on/off Complex TCC #2 , Phase on/off Complex TCC #2 , Ground on/off High current trip, Phase on/off High current trip, Ground on/off High current lockout, Phase on/off High current lockout, Ground on/off Reset target indicators Reset malfunction status indicators Reset accessory status indicators Ground trip precedence on/off Supervisory via momemtary contacts on/off SGF enable Perform combined trip & lockout/close SGF on/off Hot line tag on/off Tripping on TCC #2 only on/off UDP switch mode on/off Default Condition Comments Appendix B Page 7 of 9 Pulsed Pulsed Pulsed Pulsed Pulsed Pulsed Latched Latched Latched Latched Latched Latched Latched Latched Latched Latched Latched Latched Latched Latched Latched Latched Latched Pulsed Pulsed Pulsed Latched Latched Latched Latched Latched Latched Latched Latched Operation Type OUTPUT SUBSYSTEM - Control Output Relay Block Operations and Status F4C DNP 3.0 Device Profile data dictionary CROB & Class 0 Simple Status * 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E SBO Seq No xx Cooper 2180 Cross Reference Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output R280-90-16 Page 32 Binary Output Binary Output Binary Output Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary Binary 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 31 10 32 10 33 10 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status Status 2 Status 2 Status 2 Status 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Appendix B Page 8 of 9 * Non-latching; always reads FALSE Protocol Converter control * Restart protocol converter * Load protocol converter defaults * Force transparent mode * Perform Operation -trip * Perform Operation - close Alternate minimum trip on/off Ground trip block on/off Non-reclose on/off Power-down on/off Sequence co-ordination on/off Target reset on successful reclose on/off Operation counter on/off Event recorder on/off Interrrupter duty on/off Complex TCC #1 , Phase on/off Complex TCC #1 , Ground on/off Complex TCC #2 , Phase on/off Complex TCC #2 , Ground on/off High current trip, Phase on/off High current trip, Ground on/off High current lockout, Phase on/off High current lockout, Ground on/off * Reset target indicators * Reset malfunction status indicators * Reset accessory status indicators Ground trip precedence on/off Supervisory via momemtary contacts on/off SGF enable Perform combined trip & lockout/close SGF on/off Hot line tag on/off Tripping on TCC #2 only on/off UDP switch mode on/off F4C DNP 3.0 Device Profile data dictionary CROB & Class 0 * * * * * 30-10 30-11 30-12 31-00 31-01 31-02 31-03 31-04 31-05 31-06 31-07 31-08 31-09 31-10 31-11 31-12 31-13 * * * 31-14 31-15 35-00 30-04 35-08 35-09 35-10 35-11 70 File Identifier R280-90-16 Page 33 70 Index File Identifier Description Static Obj Var CONSTANT DATA (Read-only) 1 1 Desc PCCONST CONST File Name (All data size is 16 bits) 0 0 1 2 3 Record Number Appendix B Page 9 of 9 Protocol converter software version Control version & device code Serial number of control ( Modifiable from front panel) Display firmware version CPU firmware version Comments F4C DNP 3.0 Device Profile data dictionary 100 100 1 100 1 Scale Factor Files, Readonly Static Cooper 2180 Cross Reference Ordinal Block 5, Offset xxxx 0000 0002 0004 0006 Index R280-90-16 Page 34 File Identifier Description 70 1 Static Obj Var Desc MISC. LIVE DATA (Read-only) ERR File Name DNP last file ID write error file Comments Appendix B Page 1 of 7 0-7 ACK code 8-15 Optional error info Record Number F4C DNP 3.0 Device Profile data dictionary 1 1 Data Size (in bytes) 0000 0008 Start Offset in Record (Hex) Files, Readonly Dynamic Cooper 2180 Cross Reference Ordinal Block 0, Offset xxxx 0000 - 0007 0008 - 000F R280-90-16 Page 35 File Identifier 70 1 CFG CONFIGURATION DATA (Read/Write) (All data size is 16 bits) Static Description Index Obj Var Desc File Name 35 36 37 Appendix B Page 2 of 7 Complex TCC #1 constant time adder Ground Complex TCC #1 multiplier - Phase Complex TCC #1 multiplier - Ground Complex TCC #1 minimum response time Phase 34 31 32 33 30 TCC module Line frequency (50 Hz or 60 Hz) CT selection PGS close delay time Close re-try time Close On time Security code for Level 1 Security code for Level 2 Security code for Level 3 Minimum time on battery w/o malfunction Interrupter duty 100% value Number of close re-try attempts Minimum trip - Phase Minimum trip - Ground 1st TCC - Phase 1st TCC - Ground 2nd TCC - Phase 2nd TCC - Ground Operations on 1st TCC - Phase Operations on 1st TCC - Ground Operations to lockout - Phase Operations to lockout - Ground Sequence reset time Reclose interval 1 Reclose interval 2 Reclose interval 3 Alternate minimum trip - Phase Alternate minimum trip - Ground Remote/supervisory close reset time Set integration interval - Phase (15 min or 5 min) Set integration interval - Ground (5 min or 1 min) Complex TCC #1 selection - Phase Complex TCC #1 selection - Ground Complex TCC #1 constant time adder - Phase Comments 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Record Number F4C DNP 3.0 Device Profile data dictionary 0046 0048 004A 0044 003E 0040 0042 003C Cooper 2180 Cross Reference Ordinal Block 6, Offset xxxx 0000 0002 0004 0006 0008 000A 000C 000E 0010 0012 0014 0016 0018 001A 001C 001E 0020 0022 0024 0026 0028 002A 002C 002E 0030 0032 0034 0036 0038 003A Cycles Seconds Seconds Minutes Files, Configuration 1 100 100 100 100 1 1 1 Minutes 1 Amps Amps Minutes I ^^1.5 Seconds Seconds Cycles Seconds Seconds Seconds Seconds Amps Amps Seconds Hz Units 1 1 1 100 1 1 1 1 1 1 10^^5 1 1 1 1 1 1 1 1 1 1 1 1 10 10 10 1 1 1 Scale Factor Index R280-90-16 Page 36 File Identifier Description 70 1 Static Obj Var Desc CFG File Name SGF trip time 69 Appendix B Page 3 of 7 SGF Alternate minimum trip 68 66 67 65 64 63 62 Comm channel 2 (realtime port) baud rate code (not modifiable remotely in DNP) Comm channel 2 handshake mode code (not modifiable remotely in DNP) Comm channel 2 number of dead-line sync characters (not used in DNP) Comm channel 2 transmit enable delay (not modifiable remotely in DNP) Control remote address (not modifiable remotely in DNP) Real time clock year (not used in DNP) SGF Minimum trip % Complex TCC #2 constant time adder Ground Complex TCC #2 multiplier - Phase Complex TCC #2 multiplier - Ground Complex TCC #2 minimum response time Phase Complex TCC #2 minimum response time Ground HCT multiples of minimum trip - Phase (HCT = High Current Trip) HCT multiples of minimum trip - Ground HCT trip delay time - Phase HCT trip delay time - Ground HCT active shot number - Phase HCT active shot number - Ground HCLO multiples of minimum trip - Phase (HCLO = High Current Lockout) HCLO multiples of minimum trip - Ground HCLO active shot number - Phase HCLO active shot number - Ground Phase 1-2 Interrupter duty Phase 3-4 Interrupter duty Phase 5-6 Interrupter duty Comm channel 1 (front panel) baud rate code Complex TCC #1 minimum response time Ground Complex TCC #2 selection - Phase Complex TCC #2 selection - Ground Complex TCC #2 constant time adder - Phase Comments 61 54 55 56 57 58 59 60 48 49 50 51 52 53 47 46 43 44 45 42 39 40 41 38 Record Number F4C DNP 3.0 Device Profile data dictionary 008A 0088 0084 0086 0082 0080 007E 007C 007A 006C 006E 0070 0072 0074 0076 0078 0060 0062 0064 0066 0068 006A 005E 005C 0056 0058 005A 0054 004E 0050 0052 Cooper 2180 Cross Reference Ordinal Block 6, Offset xxxx 004C %of Ground MT %of Ground MT Seconds mSec Files, Configuration 1 1 1 1 1 1 1 1 BPS BPS 1 1 % % % Cycles Cycles Cycles Cycles Seconds Seconds Cycles Units 1 1 1 1 10 10 10 1 1 1 1 1 1 1 1 100 100 100 100 1 1 1 Scale Factor R280-90-16 Page 37 70 File Identifier 1 1 Static Obj Var Desc 70 Index File Identifier Description PCCFG CFG File Name 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 78 70 71 72 73 74 75 76 77 Record Number Appendix B Page 4 of 7 Protocol converter configuration Control unit type Control Address Control Baud Rate Ordinal Block 0 size Ordinal Block 5 size Ordinal Block 6 size Ordinal Block B size Communication mode status Communication baud rate Master Station Address Remote IED (my) Address Unsolicited Minimum Quantity per Class Unsolicited notification delay Unsolicited supported Dead Line Sync Handshake mode Transmit Enable Delay Transmit Disable Delay Channel Timeout Data Link Confirm Data Link Retries Data Link Timeout Application Retries Application Timeout Arm time Protocol converter address to controller Standard request timeout Retries for all requests (excpet time tagged) Retries for time tagged requests Ordinal Block write set-up time SGF operations to lockout Phase 1-2 target identifier Phase 3-4 target identifier Phase 5-6 target identifier UDP switch timing mode TCC (1 or 2) UDP minimum target sensing - Phase UDP minimum target sensing - Ground UDP alternate minimum target sensing Phase UDP alternate minimum target sensing Ground Comments F4C DNP 3.0 Device Profile data dictionary 009C Cooper 2180 Cross Reference Ordinal Block 6, Offset xxxx 008C 008E 0090 0092 0094 0096 0098 009A mSec mSec mSec mSec mSec mSec mSec mSec mSec 1 1 1 1 10 10 1 1 1 Files, Configuration mSec 1 Amps Amps 1 1 Amps Amps Units 1 1 1 1 1 1 1 Scale Factor Index R280-90-16 Page 38 File Identifier Description 70 1 Static Obj Var Desc CFG File Name 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 Record Number Appendix B Page 5 of 7 NOP back off time Ordinal Block Read Request timeout Interpoll Delay Protocol mode on start up Transparent mode timeout Delivery Attempts before back off Flush Events After Attempts Exhausted Backoff Terminates After Time Period Backoff Terminates On 'Enable USR' Backoff Terminates On Any Message Backoff Increment On Timeout Absolute Max Backoff Time Modem TX Idle Disconnect Time Out Modem RX Idle Disconnect Time Out Allow obsolete 0x1B qualifier for files Comments F4C DNP 3.0 Device Profile data dictionary Cooper 2180 Cross Reference Ordinal Block 6, Offset xxxx Sec Sec Sec Sec Sec Sec 1 1 1 1 1 1 Files, Configuration mSec mSec mSec Units 1 1 1 Scale Factor Index R280-90-16 Page 39 File Identifier Description 70 1 PSEUDO File Name Record Number 0 1 2 3 Appendix B Page 6 of 7 Max demand ground current Max demand current through bushing 1-2 Max demand current through bushing 3-4 Max demand current through bushing 5-6 Comments Cooper 2180 Cross Reference Ordinal Block B, Offset xxxx 0000 0002 0004 0006 Amps Amps Amps Amps Units Files, Pseudo Registers 1 1 1 1 Scale Factor These are MIN/MAX registers. Write to these points ignore data "written", present value of register is written instead. (All data size is 16 bits) Static Obj Var Desc PSEUDO REGISTERS (Read/Write) F4C DNP 3.0 Device Profile data dictionary 70 File Identifier R280-90-16 Page 40 70 Index File Identifier Description 1 1 TT001 TT000 (All data size is 16 bits) Static Obj Var Desc File Name TIME-TAGGED DATA (Read-only) Record Number 2 2 4 2 2 2 2 nn Event type ID code Date that event occurred Time that event occurred Ground current Phase 1-2 current Phase 3-4 current Phase 5-6 current 2 2 4 2 2 2 2 nn Event type ID code Date that event occurred Time that event occurred Ground current Phase 1-2 current Phase 3-4 current Phase 5-6 current Appendix B Page 7 of 7 2 2 4 2 2 2 2 0 Event type ID code Date that event occurred Time that event occurred Ground current Phase 1-2 current Phase 3-4 current Phase 5-6 current Profile recorder information 2 2 4 2 2 2 2 Data Size (in bytes) 0 Event type ID code Date that event occurred Time that event occurred Ground current Phase 1-2 current Phase 3-4 current Phase 5-6 current Event recorder information Comments F4C DNP 3.0 Device Profile data dictionary 0000 0002 0004 0008 000A 000C 000E 0000 0002 0004 0008 000A 000C 000E 0000 0002 0004 0008 000A 000C 000E 0000 0002 0004 0008 000A 000C 000E Start Offset in Record (Hex) Files, Time Tagged nn Time-Tagged Type 1, Record xx 00 nn Time-Tagged Type 0, Record xx 00 Cooper 2180 Cross Reference Kyle® Form 4C Recloser Control DNP3 Device Profile ©2003 Cooper Power Systems, Inc. Kyle® is a registered trademark of Cooper Industries, Inc. P.O. Box 1640 Waukesha, WI 53187 www.cooperpower.com KYLE 12/03