Corelite

advertisement
Corelite
DESCRIPTION
The Jaylum LED is a timeless direct/indirect pendant featuring crisp
modern lines and the latest solid state lighting and driver technology. This
highly efficient luminaire will accompany almost any décor while meeting
today’s increasingly stringent energy requirements. The Jaylum series
may be mounted individually or continuously with 4 and 8 foot modular
sections and is suited for open offices, private offices, conference rooms,
reception areas, and educational facilities. Companion wall mount and
sconce fixtures are also available to create cohesive architectural spaces.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
Construction
Low profile housing and integral gear
tray constructed from die-formed
20 gauge cold rolled steel forming a
8-1/2” x 1-1/2” profile. Fixture weight
= 4.0 lb/ft.
Reflectors
Reflector pan is painted with a high
reflectance white powder coat finish.
End Caps
Standard endcaps are rounded die
cast aluminum and mechanically
attached flush to end of fixture
without exposed fasteners. End cap
adds 1/2” at each end.
Shielding
Bottom lens is high light transmission
0.08” thick frosted acrylic material.
Optional top cover optics allow up/
down light distribution adjustment. Top
lens is 0.06” thick acrylic and does not
protrude above fixture housing.
Electrical
Long-Life LED system coupled with
electronic driver to deliver optimal
performance. LEDs are available in
3000K, 3500K or 4000K with a typical
CRI ≥ 85. Standard drivers are 0-10 volt
continuous dimming that work with
any 0-10V control/dimmer. Or, specify
the Digital Addressable Lighting
Interface (DALI) drivers; for use
with Fifth Light controls. See
ordering information for details.
Mounting
“Y” aircraft cable mounts on
4’-0” and 8’-0” centers. Refer to
installation instructions for various
ceiling interface details. Minimum
mounting height from ceiling to
top of fixture is 8”.
Finish
Fixture housings are high
reflectance white (standard) using
electrostatically applied polyester
powder coat paint. Silver and
custom colors are available.
JAYLUM - J3
Micro Prismatic/
Frosted Lens
Compliance
Components are UL recognized
and luminaires are cULus listed
for 25º C ambient environments,
damp location listed, and RoHS
compliant.
6.0”
[152mm]
LED
Suspended
Indirect/Direct
Life and Warranty
Greater than 86% lumen
maintenance expected at 60,000
hours, based off LM-80 test data
and TM-21 standards. Five-year
warranty.
1.55”
[39mm]
8.5” [216mm]
Fixture Lengths
43.5” [1105mm]
48” [1219mm]
48” [1219mm]
3.75” [95mm]
96” [2438mm]
96” [2438mm]
ORDERING INFORMATION
Sample Number: J3-UL-3L35-1D-UNV-AC48-T1-56’-STD-W
Series
Optics Up
(%Up/%Down)
J3 J
aylum Suspended
Indirect/Direct
U Open Top (Standard, 84/16)
C = Clear Top Optic (76/24)
F = Frosted Top Optic (66/34)
=
Suspension/
Power Feed
AC = A
ircraft cable
with straight
power cord
=
Suspension Length
Adjustable Cable
48”, 120”, 240”, 300”, or
360”
Optics Down
Light Level
(per 4’ section, 3500K)
Color
Temperature
rosted
F
Lens
1 Light Level 1 (2991 Lms, 23.5 W)
2 = Light Level 2 (3986 Lms, 31.5 W)
3 = Light Level 3 (4900 Lms, 39.9 W)
4 = Light Level 4 (6218 Lms, 52.2 W)
5 = Light Level 5 (7485 Lms, 64.9 W)
L30 LED 3000K
L35 = LED 3500K
L40 = LED 4000K
L
=
Ceiling Type
T1 =
T9 =
TS =
ST =
JB =
” T-Bar
1
9/16” T-Bar
Slotted T-Bar
Structure
4” Octagonal J-Box
=
Run Length
4 = 4
ft
8 = 8 ft
XX = Specify Row Length (5)
=
Number of
Circuits
1
=
1 Circuit
Driver Options
STD = Standard 0-10V
5LT = Fifth Light DALI (6)
STP = Step-Dim (Bi-Level)
Wiring
Input Voltage
C Switched Circuit
D = Dimming (2)(3)
B = Battery Pack (4)
E = Emergency Circuit
T = Night Light
Y = Daylight
=
(2)
120 = 120V
277 = 277V
UNV = Universal
(120V-277V)
Integral Sensor
(Optional)
Finish
DS = Integral Daylight
Sensor (7)
2S = Integral Occupancy/
Daylight Sensor (7)
W = White
S = Silver
CC = Custom Color
See page 2 for technical notes
PS524003EN
08/28/2015
1 of 2
JAYLUM - J3
PHOTOMETRICS
715
180°
150°
90°
0
Vertical
Angle
0º
45º
90º
0º-30º
116
3.9
45º
1371
1559
1707
0º-90º
479
16
55
1358
1541
1706
EFFICACY: 127 Lm/W
90º-130º
1563
52.3
65º
1304
1461
1619
TEST NO.: P26578
90º-180º
2512
84
75º
1138
1248
1395
0º-180º
2991
100
85º
872
763
872
WATTS: 23.5
0º
75°
358
90º
60°
536
45°
0º
90º
30°
0°
180°
15°
84% UP / 16% DOWN
150°
LAMP: (LD4) LED 3500K
135°
120°
493
90°
0
246
WATTS: 39.8 W
0º
75°
493
EFFICACY: 112 Lm/W
90º
TEST NO.: P26581
60°
45°
0º
90º
30°
985
0°
180°
15°
76% UP / 24% DOWN
165°
135°
LAMP: (LD4) LED 3500K
120°
463
90°
0
232
75°
463
WATTS: 39.8 W
0º
90º
60°
695
45°
30°
926
0°
15°
0º
90º
25°C
0º
45º
90º
261
5.9
45º
3104
3454
3722
0º-90º
1066
23.9
55º
3965
3413
3694
90º-130º
1842
41.4
65º
2923
3238
3485
90º-180º
3388
76.1
75º
2533
2753
2974
0º-180º
4453
100
85º
1853
1853
1962
Lumens
LUMINANCE DATA (CD/M2)
%
Fixture
Vertical
Angle
0º
45º
90º
0º-30º
381
8.6
45º
4461
4811
5053
0º-90º
1499
33.6
55º
4373
4721
4953
EFFICACY: 112 Lm/W
90º-130º
1177
26.4
65º
4159
4429
4677
TEST NO.: P26582
90º-180º
2957
66.4
75º
3598
3818
4002
0º-180º
4456
100
85º
2508
2617
2726
66% UP / 34% DOWN
ENERGY AND PERFORMANCE DATA
LUMEN MAINTENANCE
Ambient
Temperature
Vertical
Angle
0º-30º
Zone
LUMENS: 4456 Lm
105°
232
Lumens
LUMINANCE DATA (CD/M2)
%
Fixture
ZONAL LUMENS SUMMARY
FILE NAME:J3-FL-3L35-1D-UNV-4.IES
150°
695
Zone
LUMENS: 4453 Lm
105°
246
739
ZONAL LUMENS SUMMARY
FILE NAME: J3-CL-3L35-1D-UNV-4.IES
165°
739
926
%
Fixture
LUMENS: 2991 Lm
105°
179
985
Lumens
LAMP: (LD4) LED 3500K
120°
179
LUMINANCE DATA (CD/M2)
Zone
135°
358
715
ZONAL LUMENS SUMMARY
FILE NAME: J3-UL-1L35-1D-UNV-4.IES
165°
536
TM-21 Lumen
Maintenance
(60,000 hours)
>86%
Theoretical
L70
(Hours)
4’ – J3 LED Light Level Outputs and Distributions (3500K)
Lens
161,000
J3-UL
J3-CL
J3-FL
Light
Level
Delivered
Lumens
Wattage
Efficacy
(LPW)
1
2991
23.5
127
2
3986
31.5
127
3
4900
39.9
123
4
6218
52.2
119
5
7485
64.9
115
1
2718
23.5
116
2
3622
31.5
115
3
4453
39.9
112
4
5651
52.2
108
5
6802
64.9
105
1
2720
23.5
116
2
3625
31.5
115
3
4456
39.9
112
4
5655
52.2
108
5
6807
64.9
105
Distribution
% Up
% Down
84%
16%
76%
24%
66%
34%
TECHNICAL NOTES
1.
2.
3.
4.
5.
6.
7.
Lumen values vary depending on color temperature and lens option. Refer to photometric data for specific lumen values.
Dimming wires come standard in all LED fixtures but can be capped in the field for standard switched operation.
When dimming is selected, a separate drop for low voltage control wires supplied as standard. A single drop may be supplied upon request.
For delivered lumens, take lumens per watt of desired fixture and multiply by 12 watts (100 lp/W x 12 = 1200 lumens delivered).
Standard row configurations over 8’ consist of 4’ and 8’ luminaires.
Must be used in conjunction with a DALI control system. For a complete listing of Fifth Light Technology products and other solutions from Cooper Controls, visit www.coopercontrol.com.
Integral sensor works only with 0-10V driver and is factory prewired to the driver for stand-alone control.
Eaton
18001 E. Colfax Avenue
Aurora, CO 80011
P: 303-393-1522
www.eaton.com/lighting
Specifications and dimensions
subject to change without notice.
PS524003EN
08/28/2015
2 of 2
Download