VMVIG and DMVIG Series CHAMP Induction ® Luminaires with Induction Lighting System CL. I, DIV. 2, GROUPS A, B, C & D • CL. I, ZONE 2, GROUP IIC CL. II, DIV. 1, CL. III, GROUPS E, F, G ENCLOSURE TYPE 4X • MARINE & WET LOCATIONS CHAMP Induction ® Applications Include: Petrochemical Facilities Get uninterrupted light for up to 11 years, without changing a lamp. Cooper Crouse-Hinds ® Champ Luminaire with Induction Light Source delivers up to 100,000 hours of white light in a hazardous location, corrosion-resistant watertight package. That’s 5 to 8 times the typical life of conventional fluorescent or HID lamps. And, with no maintenance required for up to 11 years, you’ll reduce your maintenance and lamp replacement costs. Compelling reasons to choose the new Champ Induction Luminaire as the light source for industrial and hazardous locations include: NEW 165W Champ Induction provides as much light as a 175W Metal Halide but lasts 7 times longer! • Crisp white light (80+ color rendering index) provides increased safety by clearly illuminating signs, instrument panels, equipment and more with vibrant natural colors. Manufacturing Areas • Up to 100,000 hours of lamp life minimizes routine maintenance costs. If you operate this luminaire for 24 hours, 7 days a week, you will not need to change the lamp for up to 11 years! • Instant illumination — no waiting for lamp warm-up time. Increases productivity and safety. • Delivers the best possible luminaire temperature rating — T6 (85°C) when used with the Champ restricted breathing option. Ideal for hazardous areas where a low ignition temperature is required. Waste Water Treatment • Starts in low temperatures — as low as -40°C. ADDITIONAL FEATURES & BENEFITS The Champ Induction Luminaire is suitable for Class I, Division 2 and Zone 2 areas with the assurance of Cooper Crouse-Hinds quality and reliability. They are ideal for use in hard-to-reach applications and where process requirements demand continuous luminaire operation. Features Food Processing Facilities • High lumens per watts (72 lpw for the 165W Champ) will save energy. • Retains strong light output (retains more than 70% output) throughout the life of the lamp. • Will not add electrical noise to the circuits — Total Harmonic Distortion is less than 10%. Paper and Pulp Operations • Excellent power factor of .96 increases useable watts to an excellent level and reduces energy consumption. • Internal electronics are enclosed to ensure that there is no interference with external instrumentation. APPLICATIONS: Champ Induction Luminaires are ideal: Pharmaceutical Manufacturing 2 • Where an extra long life lamp source (up to 100,000 hrs) is required. • In areas that require lamps to reach full illumination immediately. • Where cool temperature ratings on the luminaire globe are needed to ensure safe operation in hazardous areas. • In hard-to-reach applications where relamping is costly. • Where luminaire maintenance is difficult due to continuous process operation requirements that restrict or prohibit shut down except in emergency situations. • To provide a cost-effective lighting system (low installed/life cost) by minimizing or even eliminating routine luminaire maintenance. • In cold environment applications. Induction Lighting System VMVIG and DMVIG Series Class I, Division 2 Groups A, B, C, D • Class I, Zone 2 Group IIC • Class II, Division 1, Class III, Groups E, F, G • Restricted Breathing Suffix S826 for Class I, Division 2 & Zone 2 Marine Locations • Wet Locations • Enclosure Type 3, 3R, 4, 4X and IP66 CERTIFICATIONS & COMPLIANCES: ACCESSORIES: MOUNTING MODULES NEC & CEC: • Class I, Division 2 and Zone 2 • Class I, Division 2 Groups A, B, C, D Class I, Zone 2 Group IIC • Class II, Division 1, Class III, Groups E, F, G • Restricted Breathing Suffix S826 for Class I, Division 2 & Zone 2 • Marine Locations, Wet Locations, Enclosure Type 3, 3R, 4, 4X and IP66 • UL and cUL Listed UL Standards: 844, 60079-15, 1598, 1598A CSA Standards: C22.2 No.137, E79 Series Compliances and aprovals for the lamp system • RFI < 30 MHz EN 55015 • RFI > 30 MHz EN 55022 • Harmonics EN 61000-3-2 • Immunity EN 61547 • Safety EN 61347-2-3 & UL935 EN 60928 • Performance EN 60929 • Vibration & bump tests IEC 68-2-6-Fc IEC 68-2-29-Eb • Quality standards ISO 9001 • Environmental standard ISO 14001 STANDARD MATERIALS: CAT NO. ¾ NPT Pendant 1 NPT Pendant ¾ NPT Flexible Pendant ¾ NPT Ceiling Mount 1 NPT Ceiling Mount ¾ NPT Wall Mount 1 NPT Wall Mount ¾ NPT Quad Mount 1 ½ NPT Stanchion Mount — 25 Degree Angle 1 ½ NPT Stanchion Mount — Straight WATTAGE DOME REFLECTOR CATALOG NO. 55W 85W 165W ANGLE REFLECTORS CATALOG NO. RD70 RD739 RD739 RA70 RA739 RA739 REFRACTORS Glass Wattage Type II Type III Type V 55W R2 R3 R5 85W GR302 GR303 GR305 165W GR302 GR303 GR305 Plastic • Ballast housings and mountings — copper-free aluminum (less than 0.4 of 1%) • Exterior hardware — stainless steel • Reflectors (dome and angle) — Krydon® fiberglass-reinforced polyester material • Globes — heat and impact-resistant internally fluted glass • Guards — copper-free aluminum (55W), stainless steel (85W) APM2 APM3 HPM2 CM2 CM3 TWM2 TWM3 QM25 JM5 PM5 Compact Wattage Type II Type III Type V Type I Type V 55W PR2 PR3 PR5 G241* G245* 85W PGR302 PGR303 PGR305 165W PGR302 PGR303 PGR305 *Optional stainless steel wire guard P241 available with compact refractors. DIMENSIONS STANDARD FINISHES: See Catalog Section 3L for dimensional information on VMV and DMV Series • Copper-free aluminum — epoxy powder coat • Krydon material — high reflectance white • Stainless steel — natural AMPERAGE: Power consumption for specific voltages as follows: 55W LUMINARIES OPTIONS: DESCRIPTION Restricted Breathing Construction Class I, Division 2 & Zone 2 suitability Cooler operating temperatures (T-Codes) SUFFIX TO ADD TO CATALOG NO. S826 a. 120VAC x 460mA = 55.70 watts b. 230VAC x 260mA = 59.80 watts 85W LUMINARIES c. 120VAC x 710mA = 85.20 watts d. 230VAC x 400mA = 92.00 watts 165W LUMINARIES e. 230VAC x 700mA = 161.00 watts 3 CHAMP Induction ® Induction Lighting System VMVIG and DMVIG Series Class I, Division 2 Groups A, B, C, D • Class I, Zone 2 Group IIC • Restricted Breathing Suffix S826 for Class I, Division 2 & Zone 2 Marine Locations • Wet Locations • Enclosure Type 3, 3R, 4, 4X and IP66 LAMP DATA: SYSTEM POWER (W) LUMEN (LM) INITIAL MEAN EFFICACY (LM/W) INITIAL MEAN COLOR RENDERING INDEX* LUMEN MAINTENANCE AFTER 60,000 HRS (%) VMV 55 3500 2800 65 51 80 75 DMV DMV 85 165 6000 12000 4800 9600 70 72 57 58 80 80 75 70 *Lamp sources with 80+ CRI provide excellent color rendering. CRI scale is 0-100 with 100 considered as ideal TEMPERATURE PERFORMANCE DATA: CATALOG # WATTS AMBIENT TEMP °C SUPPLY WIRE TEMP °C CLASS I, DIV. 2 CLASS II, DIV. 1, TEMP. RATING CLASS III GROUPS A, B, C, D TEMP. RATING GROUPS E, F, G SIMULTANEOUS PRESENCE CLASS I, DIV. 2 RESTRICTED BREATHING (SUFFIX S826) Aex nR IIC, Ex nR IIC CLASS I, DIV. 2/Zone 2 GROUP IIC VMVIG055 55 40 60 T2C – – T6 VMVIG055 55 55 75 T2C – – T5 DMVIG085 85 40 60 T2D T5 T2D T6 DMVIG085 85 55 75 T2D – – T6 DMVIG165 165 40 75 T3 – – T5 Champ Induction DMV 85-watt is now Class II Div. 1– suitable for dust environments! ORDERING INFORMATION: To complete catalog number, add voltage and option suffix(es). MOUNTING STYLE HUB SIZE (INCHES) 55W INDUCTION CATALOG NUMBER (WITH G24 GLOBE & P21 GUARD) 85W INDUCTION CATALOG NUMBER (WITH G303 GLOBE & P33 GUARD) 165W INDUCTION CATALOG NUMBER (WITH G303 GLOBE & P33 GUARD) Pendant ¾ 1 VMVIG2A055GP VMVIG3A055GP DMVIG2A085GP DMVIG3A085GP DMVIG2A165GP* DMVIG3A165GP* Flexible Pendant ¾ VMVIG2HA055GP DMVIG2HA085GP DMVIG2HA165GP* Ceiling Mount ¾ 1 VMVIG2C055GP VMVIG3C055GP DMVIG2C085GP DMVIG3C085GP DMVIG2C165GP* DMVIG3C165GP* Wall Mount ¾ 1 VMVIG2TW055GP VMVIG3TW055GP DMVIG2TW085GP DMVIG3TW085GP DMVIG2TW165GP* DMVIG3TW165GP* Quad Mount ¾ VMVIG25Q055GP DMVIG25Q085GP DMVIG25Q165GP* Stanchion Mount 25° Angle 1½ VMVIGJ055GP DMVIGJ085GP DMVIGJ165GP* Stanchion Mount Straight 1½ VMVIG2P055GP DMVIG2P085GP DMVIG2P165GP* Luminaire with Globe and Guard less Mounting Module — VMVIG055GP DMVIG085GP DMVIG165GP* 4 Champ Induction DMV 165-watt is now available in 120 Volt! Add the voltage suffix to the above catalog number. Standard Voltage Suffix 120V, 50/60 Hz /120 Operative range of 108-132 VAC 200V-277V, 50/60 Hz /200 277 Operates on 208, 220, 230, 240, 277 VAC Ex. - DMVIG2A165GP/120 Photometric Data LUMINAIRE WITH GLOBE AND GUARD VMVIG055GP LAMP: 55W INDUCTION 55 WATT INDUCTION 180° 160° 140° 120° 130° 110° 100° 90° SIDE 80° CANDLEPOWER DISTRIBUTION (IN CANDELAS) 70° 75 60° 150 FRONT CANDELAS Vertical Angle 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 ZONAL LUMENS Front Side 174 171 174 210 243 271 284 289 292 288 281 271 241 197 142 60 5 0 0 0 0 174 171 174 214 246 266 279 284 287 282 276 268 238 196 142 59 5 0 0 0 0 With Zone 0 – 10 10 – 20 20 – 30 30 – 40 40 – 50 50 – 60 60 – 70 70 – 80 80 – 90 90 – 100 100 – 110 110 – 120 120 – 130 130 – 140 140 – 150 150 – 160 160 – 170 170 – 180 Lumens 16 50 98 154 208 252 284 306 310 293 252 194 126 48 4 0 0 0 Total Note: Photometric data was developed using a 55W induction lamp (3,500 lumens). COEFFICIENTS OF UTILIZATION Effective Floor Cavity Reflectance 20% ROOM CAVITY RATIO Eff. Ceil. Wall 3 4 7 8 9 10 80* 50* .661 30* .617 10* .577 .552 .488 .435 .473 .402 .346 .411 .337 .281 .357 .314 .283 .242 .228 .190 .280 .210 .161 .250 .183 .137 .224 .159 .116 .203 .142 .101 70* 50* .618 30* .579 10* .543 .515 .458 .409 .441 .377 .326 .383 .316 .265 .332 .293 .265 .227 .215 .179 .261 .197 .151 .233 .171 .128 .209 .149 .109 .190 .133 .095 50* 50* .538 30* .506 10* .478 .445 .399 .360 .381 .329 .286 .331 .276 .233 .286 .253 .231 .198 .188 .157 .225 .171 .132 .201 .149 .112 .181 .130 .095 .164 .116 .082 30* 50* .464 30* .439 10* .416 .380 .344 .312 .325 .283 .249 .282 .238 .202 .244 .215 .198 .170 .163 .135 .192 .147 .114 .172 .128 .096 .154 .111 .081 .140 .099 .070 10* 50* .395 30* .376 10* .359 .321 .293 .267 .273 .240 .212 .236 .201 .172 .204 .180 .167 .143 .137 .114 .161 .124 .095 .144 .107 .080 .129 .093 .067 .118 .083 .057 0* 0* .324 .235 .183 .146 .113 .092 .075 .061 .050 .042 2596 3 2 50° 225 1 2 5 6 1 *Percent Reflectance A 0 B D C ISOFOOTCANDLE CHART: 300 Footcandle Values for Isofootcandle Lines -1 40° Mtg. Hgt. A B C D E 10' 12' 16' 20' 25' 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 0.20 0.14 0.08 0.05 0.03 0.10 0.07 0.04 0.03 0.02 0.05 0.03 0.02 0.01 0.01 -2 E -3 -3 0° 130° 120° CANDELAS Vertical 110° Angle 0 5 CANDLEPOWER DISTRIBUTION (IN CANDELAS) 15 25 35 100° 45 55 65 75 90° 85 90 95 105 80° 115 125 135 145 155 70° 165 175 180 125 0 1 2 3 Isofootcandle chart shows illuminance in footcandles at ground level. LUMINAIRE WITH GLOBE AND RD70 DOME REFLECTOR VMVIG055GP LAMP: 55W INDUCTION 55 WATT INDUCTION 180° 160° 150° 140° -1 RATIO OF DISTANCE TO MOUNTING HEIGHT 30° 20° 10° -2 ZONAL LUMENS Front Side 493 488 469 480 503 490 457 392 217 42 10 7 6 11 8 1 1 1 0 1 1 493 488 469 478 491 482 458 402 219 42 10 7 4 8 7 1 1 1 0 1 1 With Zone 0 – 10 10 – 20 20 – 30 30 – 40 40 – 50 50 – 60 60 – 70 70 – 80 80 – 90 90 – 100 100 – 110 110 – 120 120 – 130 130 – 140 140 – 150 150 – 160 160 – 170 170 – 180 Lumens 46 133 223 314 377 408 388 231 53 7 5 9 6 1 1 0 0 0 Total F 60° COEFFICIENTS OF UTILIZATION Effective Floor Cavity Reflectance 20% ROOM CAVITY RATIO Eff. Ceil. Wall 6 4 7 8 9 10 50* .646 30* .617 10* .591 .555 .509 .470 .482 .427 .383 .420 .361 .316 .364 .321 .303 .260 .257 .216 .285 .225 .183 .253 .195 .155 .225 .169 .131 .203 .149 .114 70* 50* .630 30* .604 10* .581 .542 .499 .464 .471 .420 .379 .411 .356 .313 .356 .314 .298 .256 .255 .215 .279 .222 .182 .248 .193 .154 .221 .167 .130 .200 .148 .113 50* 50* .602 30* .580 10* .561 .518 .482 .451 .450 .407 .371 .394 .346 .308 .341 .301 .290 .250 .252 .212 .268 .217 .180 .238 .188 .152 .212 .163 .129 .192 .145 .112 30* 50* .576 30* .558 10* .542 .496 .466 .440 .432 .395 .363 .378 .336 .303 .327 .290 .283 .244 .248 .209 .258 .212 .178 .230 .184 .151 .205 .160 .127 .186 .142 .111 10* 50* .552 30* .538 10* .524 .475 .450 .428 .414 .383 .356 .363 .327 .298 .315 .278 .276 .238 .244 .206 .248 .207 .176 .221 .180 .149 .197 .156 .126 .179 .139 .110 0* 0* .510 .414 .341 .283 .230 .192 .162 .136 .113 .098 F 2 5 3 80* 2202 3 250 Note: Photometric data was developed using a 55W induction lamp (3,500 lumens). 1 2 1 SIDE 375 A B C 0 D E 50° *Percent Reflectance ISOFOOTCANDLE CHART: Footcandle Values for Isofootcandle Lines -1 FRONT -2 F 40° 500 0° 10° 20° 30° -3 -3 F -2 -1 0 1 2 3 RATIO OF DISTANCE TO MOUNTING HEIGHT Mtg. Hgt. A B C D E F 10' 12' 16' 20' 25' 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 0.20 0.14 0.08 0.05 0.03 0.10 0.07 0.04 0.03 0.02 0.05 0.03 0.02 0.01 0.01 Isofootcandle chart shows illuminance in footcandles at ground level. Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our ® Luxicon Lighting Layout Software are available to download. 5 CHAMP Induction ® Photometric Data 55 WATT INDUCTION 140° 150° 160° 170° 180° 170° 160° LUMINAIRE WITH GLOBE AND RA70 (30° ANGLE) REFLECTOR VMVIG055GP LAMP: 55W INDUCTION 150° 140° CANDELAS 130° 130° CANDLEPOWER DISTRIBUTION (IN CANDELAS) 120° 120° 110° 110° 100° 100° FRONT 90° 90° 80° 80° 70° 150 SIDE 70° BACK SIDE 60° 300 60° ZONAL LUMENS Vertical With Angle Front Side Back Zone 0 474 474 474 0 – 10 5 489 467 449 10 – 20 15 499 443 381 20 – 30 25 518 440 354 30 – 40 35 549 448 334 40 – 50 45 588 440 208 50 – 60 55 614 416 46 60 – 70 65 584 305 4 70 – 80 75 527 132 1 80 – 90 85 464 24 2 90 – 100 90 424 6 2 100 – 110 95 351 3 2 110 – 120 105 157 1 2 120 – 130 115 25 3 7 130 – 140 125 2 2 6 140 – 150 135 0 0 2 150 – 160 145 0 0 0 160 – 170 155 0 0 0 170 – 180 165 0 0 0 Total 175 0 0 0 180 0 0 0 Lumens 44 126 204 282 329 320 280 228 167 95 33 8 3 0 0 0 0 0 Note: Photometric data was developed using a 55W induction lamp (3,500 lumens). COEFFICIENTS OF UTILIZATION Effective Floor Cavity Reflectance 20% ROOM CAVITY RATIO Eff. Ceil. Wall 1 2 3 4 7 8 9 10 80* 50* 30* 10* .599 .567 .539 .513 .465 .425 .447 .392 .349 .392 .334 .290 .343 .304 .284 .246 .240 .204 .271 .214 .174 .242 .186 .148 .216 .162 .126 .196 .144 .110 70* 50* 30* 10* .581 .552 .526 .497 .454 .417 .434 .383 .343 .381 .327 .286 .333 .296 .278 .241 .237 .201 .264 .210 .172 .236 .183 .147 .210 .160 .125 .191 .142 .109 50* 50* 30* 10* .547 .524 .502 .469 .432 .401 .409 .367 .331 .360 .314 .277 .315 .280 .267 .232 .230 .196 .251 .203 .168 .224 .177 .143 .200 .154 .122 .182 .137 .106 30* 50* 30* 10* .516 .497 .479 .442 .412 .386 .387 .351 .320 .341 .301 .269 .299 .266 .257 .223 .224 .191 .238 .195 .164 .213 .171 .140 .190 .149 .119 .173 .133 .104 10* 50* 30* 10* .488 .472 .458 .418 .393 .371 .366 .336 .310 .323 .289 .261 .283 .253 .247 .215 .218 .186 .226 .189 .160 .203 .165 .136 .181 .144 .116 .165 .128 .102 0* 0* .442 .355 .294 .246 .203 .172 .146 .123 .104 .090 2120 3 50° 450 50° 40° 2 5 6 1 *Percent Reflectance 600 40° D E A B C 0 ISOFOOTCANDLE CHART: Footcandle Values for Isofootcandle Lines -1 750 30° -2 -3 -3 900 20° 10° 0° 10° 85 WATT INDUCTION 180° 160° 140° 20° A B C D E F 10' 12' 16' 20' 25' 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 0.20 0.14 0.08 0.05 0.03 0.10 0.07 0.04 0.03 0.02 0.05 0.03 0.02 0.01 0.01 -1 0 1 2 3 Isofootcandle chart shows illuminance in footcandles at ground level. LUMINAIRE WITH GLOBE AND GUARD DMVIG085GP LAMP: 85W INDUCTION 120° 130° -2 RATIO OF DISTANCE TO MOUNTING HEIGHT 30° Mtg. Hgt. F 110° 100° 90° 80° CANDLEPOWER DISTRIBUTION (IN CANDELAS) 70° 150 60° 300 CANDELAS Vertical Angle 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 ZONAL LUMENS With Zone 0 – 10 10 – 20 20 – 30 30 – 40 40 – 50 50 – 60 60 – 70 70 – 80 80 – 90 90 – 100 100 – 110 110 – 120 120 – 130 130 – 140 140 – 150 150 – 160 160 – 170 170 – 180 Candela 524 516 529 551 561 567 561 564 555 524 503 482 415 324 218 107 28 12 8 1 1 Total Lumens 49 150 255 353 439 504 559 585 571 524 439 322 196 85 20 6 2 0 Note: Photometric data was developed using a 85W induction lamp (6,000 lumens). COEFFICIENTS OF UTILIZATION Effective Floor Cavity Reflectance 20% ROOM CAVITY RATIO Eff. Ceil. Wall 4 7 8 9 10 50* .765 30* .715 10* .671 .642 .571 .511 .553 .473 .410 .482 .399 .336 .419 .371 .336 .290 .275 .232 .331 .252 .197 .296 .220 .168 .266 .193 .144 .241 .172 .126 70* 50* .719 30* .675 10* .635 .602 .538 .484 .519 .447 .389 .452 .377 .319 .394 .349 .318 .274 .261 .220 .311 .239 .187 .279 .209 .160 .250 .183 .137 .228 .163 .119 50* 50* .633 30* .598 10* .566 .528 .477 .432 .455 .396 .348 .397 .335 .286 .345 .306 .282 .244 .234 .197 .274 .212 .168 .245 .186 .143 .220 .163 .122 .201 .145 .107 30* 50* .555 30* .527 10* .502 .460 .419 .383 .396 .349 .309 .345 .295 .254 .300 .267 .248 .214 .207 .175 .239 .187 .149 .214 .163 .127 .193 .143 .108 .176 .128 .094 10* 50* .482 30* .461 10* .441 .397 .365 .336 .341 .303 .271 .297 .257 .223 .258 .229 .215 .186 .181 .152 .206 .163 .130 .185 .142 .110 .166 .124 .093 .152 .111 .082 0* 0* .301 .240 .194 .155 .128 .108 .090 .075 .064 5059 3 2 50° 6 3 80* 1 .404 2 5 1 450 *Percent Reflectance A 0 B C D E ISOFOOTCANDLE CHART: Footcandle Values for Isofootcandle Lines -1 600 40° -2 F -3 -3 0° 10° 20° 30° -2 -1 0 2 RATIO OF DISTANCE TO MOUNTING HEIGHT Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our ® Luxicon Lighting Layout Software are available to download. 6 1 3 Mtg. Hgt. A B C D E F 10' 12' 16' 20' 25' 5.00 3.47 1.95 1.25 0.80 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 0.20 0.14 0.08 0.05 0.03 0.10 0.07 0.04 0.03 0.02 Isofootcandle chart shows illuminance in footcandles at ground level. Photometric Data 85 WATT INDUCTION 180° 160° LUMINAIRE WITH GLOBE AND WITH RD739 DOME REFLECTOR DMVIG085 LAMP: 85W INDUCTION 120° 140° CANDLEPOWER DISTRIBUTION (IN CANDELAS) Need Photo 250 CANDELAS Vertical 110° Angle 0 5 15 25 35 100° 45 55 65 75 90° 85 90 95 105 80° 115 125 135 145 155 70° 165 175 180 ZONAL LUMENS With Zone 0 – 10 10 – 20 20 – 30 30 – 40 40 – 50 50 – 60 60 – 70 70 – 80 80 – 90 90 – 100 100 – 110 110 – 120 120 – 130 130 – 140 140 – 150 150 – 160 160 – 170 170 – 180 Candela 976 977 1004 1009 997 952 848 723 460 146 36 12 11 15 16 9 3 2 2 1 1 Lumens 94 284 467 626 733 760 712 485 163 15 12 14 14 7 2 1 1 0 Total Note: Photometric data was developed using a 85W induction lamp (6,000 lumens). COEFFICIENTS OF UTILIZATION Effective Floor Cavity Reflectance 20% ROOM CAVITY RATIO Eff. Ceil. Wall 3 4 7 8 9 10 80* 50* .747 30* .712 10* .681 .641 .587 .541 .558 .493 .442 .488 .419 .367 .424 .375 .353 .305 .301 .254 .334 .265 .217 .298 .230 .184 .265 .200 .156 .240 .178 .136 70* 50* .729 30* .697 10* .669 .626 .576 .533 .545 .485 .437 .477 .413 .363 .415 .368 .348 .301 .298 .252 .328 .262 .215 .292 .228 .183 .260 .198 .155 .236 .176 .136 50* 50* .695 30* .669 10* .646 .598 .555 .519 .521 .470 .428 .457 .401 .357 .398 .353 .339 .293 .294 .249 .315 .256 .213 .281 .223 .181 .251 .194 .154 .227 .172 .134 30* 50* .664 30* .643 10* .624 .571 .536 .505 .499 .456 .419 .438 .390 .351 .382 .339 .330 .286 .289 .246 .303 .250 .210 .270 .218 .179 .241 .189 .152 .219 .169 .133 10* 50* .636 30* .619 10* .603 .547 .518 .492 .478 .442 .410 .421 .379 .345 .367 .326 .321 .279 .285 .242 .291 .244 .208 .260 .213 .177 .233 .185 .151 .212 .165 .132 0* 0* .586 .475 .393 .327 .268 .226 .192 .162 .136 .118 4391 3 F 60° 500 F 2 1 2 6 5 1 *Percent Reflectance B C D A 0 E 50° 750 ISOFOOTCANDLE CHART: Footcandle Values for Isofootcandle Lines -1 Mtg. Hgt. A B C D E F 10' 12' 16' 20' 25' 5.00 3.47 1.95 1.25 0.80 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 0.20 0.14 0.08 0.05 0.03 0.10 0.07 0.04 0.03 0.02 -2 F 40° 1000 0° 10° 20° 150° 160° 170° 180° 170° 160° F -2 -1 0 140° 150° CANDELAS 130° CANDLEPOWER DISTRIBUTION (IN CANDELAS) 120° 120° 110° 110° 100° FRONT 90° 90° 80° 80° 150 70° SIDE 60° BACK 3 Isofootcandle chart shows illuminance in footcandles at ground level. ZONAL LUMENS Vertical 70° 2 LUMINAIRE WITH GLOBE AND RA739 (30° ANGLE) REFLECTOR DMVIG085 LAMP: 85W INDUCTION 130° Angle Front Side Back 100° 1 RATIO OF DISTANCE TO MOUNTING HEIGHT 30° 85 WATT INDUCTION 140° -3 -3 SIDE 300 60° 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 931 970 1077 1141 1156 1160 1137 1086 1006 874 773 648 353 90 9 2 1 1 0 0 3 931 926 946 951 939 867 780 586 313 81 22 12 9 8 9 7 6 6 5 4 3 931 885 836 757 660 409 120 19 5 6 6 7 8 11 17 13 4 4 3 1 3 With Lumens Zone 0 – 10 89 10 – 20 269 20 – 30 440 30 – 40 577 40 – 50 643 50 – 60 616 60 – 70 542 70 – 80 447 80 – 90 328 90 – 100 197 100 – 110 85 110 – 120 23 120 – 130 11 130 – 140 6 140 – 150 3 150 – 160 2 160 – 170 1 170 – 180 0 Total Note: Photometric data was developed using a 85W induction lamp (6,000 lumens). COEFFICIENTS OF UTILIZATION Effective Floor Cavity Reflectance 20% ROOM CAVITY RATIO Eff. Ceil. Wall 1 2 3 4 7 8 9 10 80* 50* 30* 10* .706 .669 .636 .606 .551 .504 .529 .466 .415 .465 .398 .347 .408 .363 .339 .295 .288 .246 .324 .258 .211 .289 .225 .181 .259 .196 .154 .235 .175 .135 70* 50* 30* 10* .684 .651 .621 .587 .537 .494 .513 .455 .408 .452 .390 .342 .396 .353 .332 .289 .284 .243 .315 .253 .208 .282 .221 .178 .252 .193 .152 .229 .172 .133 50* 50* 30* 10* .643 .616 .591 .552 .510 .474 .484 .434 .393 .427 .373 .331 .374 .334 .319 .278 .276 .236 .299 .243 .203 .268 .213 .174 .240 .186 .149 .218 .166 .130 30* 50* 30* 10* .605 .583 .563 .520 .485 .455 .456 .415 .380 .403 .357 .320 .354 .316 .306 .267 .268 .229 .284 .234 .198 .254 .205 .169 .228 .179 .145 .207 .160 .127 10* 50* 30* 10* .571 .553 .536 .490 .462 .436 .431 .396 .366 .381 .342 .310 .335 .300 .293 .257 .260 .223 .269 .226 .192 .241 .198 .165 .217 .173 .141 .197 .155 .124 0* 0* .517 .417 .347 .292 .242 .206 .176 .150 .127 .110 4279 3 50° 450 50° 40° 2 5 6 1 *Percent Reflectance 600 40° B C D A 0 E ISOFOOTCANDLE CHART: Footcandle Values for Isofootcandle Lines -1 750 30° F -2 -3 -3 900 20° 10° 0° 10° 20° 30° -2 -1 0 1 2 3 RATIO OF DISTANCE TO MOUNTING HEIGHT Mtg. Hgt. A B C D E F 10' 12' 16' 20' 25' 5.00 3.47 1.95 1.25 0.80 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 0.20 0.14 0.08 0.05 0.03 0.10 0.07 0.04 0.03 0.02 Isofootcandle chart shows illuminance in footcandles at ground level. Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our ® Luxicon Lighting Layout Software are available to download. 7 CHAMP Induction ® Photometric Data 165 WATT INDUCTION 180° 170° 160° 150° 140° LUMINAIRE WITH GLOBE DMVIG165G LAMP: 165W INDUCTION 120° 130° 110° 100° 90° 80° 275 CANDLEPOWER DISTRIBUTION (IN CANDELAS) 70° CANDELAS Vertical Angle 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 ZONAL LUMENS With Zone 0 – 10 10 – 20 20 – 30 30 – 40 40 – 50 50 – 60 60 – 70 70 – 80 80 – 90 90 – 100 100 – 110 110 – 120 120 – 130 130 – 140 140 – 150 150 – 160 160 – 170 170 – 180 Candela 857 860 926 982 1012 1041 1086 1123 1133 1122 1112 1106 1052 939 754 509 245 36 1 0 0 Total Lumens 83 263 454 635 807 975 1113 1198 1223 1205 1111 930 676 396 157 22 0 0 Note: Photometric data was developed using a 165W induction lamp (12,000 lumens). COEFFICIENTS OF UTILIZATION Effective Floor Cavity Reflectance 20% ROOM CAVITY RATIO Eff. Ceil. Wall 1 2 3 4 7 8 9 10 80* 50* 30* 10* .834 .781 .732 .700 .623 .558 .603 .516 .447 .525 .435 .366 .458 .405 .367 .316 .300 .253 .361 .275 .215 .323 .241 .184 .291 .211 .158 .264 .188 .138 70* 50* 30* 10* .776 .728 .685 .650 .581 .522 .560 .482 .419 .487 .406 .343 .425 .376 .343 .295 .281 .237 .336 .257 .202 .301 .225 .172 .270 .197 .148 .246 .176 .129 50* 50* 30* 10* .666 .629 .595 .555 .500 .453 .477 .415 .364 .416 .350 .299 .362 .321 .295 .255 .244 .205 .287 .222 .175 .257 .194 .149 .231 .170 .127 .211 .152 .111 30* 50* 30* 10* .566 .537 .510 .467 .425 .387 .401 .352 .311 .350 .297 .255 .304 .269 .250 .215 .207 .174 .241 .188 .148 .217 .164 .126 .195 .144 .107 .178 .129 .094 10* 50* 30* 10* .473 .451 .431 .386 .354 .324 .331 .293 .260 .288 .247 .213 .249 .221 .206 .178 .172 .144 .198 .155 .122 .178 .135 .104 .160 .118 .088 .147 .106 .076 0* 0* .384 .282 .222 .178 .141 .116 .097 .080 .066 .057 11248 3 E E 2 550 5 6 1 60° *Percent Reflectance B C A 0 D ISOFOOTCANDLE CHART: 825 Footcandle Values for Isofootcandle Lines -1 50° E 10° 20° 30° 180° 170° 160° 150° 140° B C D E 5.00 3.47 1.95 1.25 0.80 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 0.20 0.14 0.08 0.05 0.03 E -2 -1 0 1 2 3 Isofootcandle chart shows illuminance in footcandles at ground level. RATIO OF DISTANCE TO MOUNTING HEIGHT 40° 165 WATT INDUCTION A 10' 12' 16' 20' 25' -2 -3 -3 1100 Mtg. Hgt. LUMINAIRE WITH GLOBE AND GUARD DMVIG165GP LAMP: 165W INDUCTION 120° 130° 110° 100° 90° 80° 275 CANDLEPOWER DISTRIBUTION (IN CANDELAS) 70° CANDELAS Vertical Angle 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 ZONAL LUMENS With Zone 0 – 10 10 – 20 20 – 30 30 – 40 40 – 50 50 – 60 60 – 70 70 – 80 80 – 90 90 – 100 100 – 110 110 – 120 120 – 130 130 – 140 140 – 150 150 – 160 160 – 170 170 – 180 Candela 892 901 946 984 985 998 1034 1068 1083 1075 1062 1055 991 877 698 472 236 51 15 2 2 Total Lumens 87 269 455 619 773 928 1061 1143 1171 1147 1046 868 626 367 151 28 4 0 ROOM CAVITY RATIO Eff. Ceil. Wall 1 2 3 4 7 8 9 10 80* 50* 30* 10* .798 .747 .701 .670 .596 .534 .578 .495 .429 .504 .418 .352 .439 .389 .353 .304 .289 .243 .347 .265 .208 .311 .232 .178 .279 .204 .153 .254 .182 .134 70* 50* 30* 10* .743 .697 .656 .623 .557 .501 .537 .462 .402 .468 .390 .330 .408 .361 .330 .284 .271 .228 .323 .248 .195 .289 .217 .167 .260 .191 .143 .237 .170 .125 50* 50* 30* 10* .639 .603 .571 .533 .481 .435 .459 .399 .350 .400 .338 .288 .349 .309 .285 .246 .236 .199 .277 .215 .169 .248 .188 .145 .224 .165 .124 .204 .147 .109 30* 50* 30* 10* .544 .516 .491 .450 .409 .373 .387 .340 .300 .337 .287 .247 .293 .261 .242 .209 .201 .170 .234 .183 .144 .210 .160 .123 .189 .140 .105 .173 .125 .092 10* 50* 30* 10* .456 .435 .416 .373 .342 .314 .320 .283 .252 .279 .239 .207 .242 .215 .201 .173 .168 .141 .193 .152 .120 .174 .133 .102 .156 .116 .087 .143 .104 .076 0* 0* .372 .274 .216 .174 .138 .114 .096 .080 .066 .057 3 E 60° COEFFICIENTS OF UTILIZATION Effective Floor Cavity Reflectance 20% 10743 E 2 550 Note: Photometric data was developed using a 165W induction lamp (12,000 lumens). 5 6 1 *Percent Reflectance B C A 0 D ISOFOOTCANDLE CHART: 825 Footcandle Values for Isofootcandle Lines -1 50° -2 E -3 -3 1100 10° 20° 30° 40° E -2 -1 0 2 RATIO OF DISTANCE TO MOUNTING HEIGHT Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our ® Luxicon Lighting Layout Software are available to download. 8 1 3 Mtg. Hgt. A B C D E 10' 12' 16' 20' 25' 5.00 3.47 1.95 1.25 0.80 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 0.20 0.14 0.08 0.05 0.03 Isofootcandle chart shows illuminance in footcandles at ground level. Photometric Data LUMINAIRE WITH GLOBE AND RD739 DOME REFLECTOR DMVIG165G LAMP: 165W INDUCTION 165 WATT INDUCTION 170° 150° 140° 130° 120° 110° CANDELAS Vertical 90° 80° 450 70° 60° CANDLEPOWER DISTRIBUTION (IN CANDELAS) 900 ZONAL LUMENS With Zone 0 – 10 10 – 20 20 – 30 30 – 40 40 – 50 50 – 60 60 – 70 70 – 80 80 – 90 90 – 100 100 – 110 110 – 120 120 – 130 130 – 140 140 – 150 150 – 160 160 – 170 170 – 180 Candela 100° Angle 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 1781 1790 1835 1820 1756 1685 1594 1469 1193 717 459 260 26 18 25 27 16 4 4 3 4 Total Lumens 171 520 841 1103 1303 1428 1451 1253 782 292 39 18 22 21 11 2 1 0 Note: Photometric data was developed using a 165W induction lamp (12,000 lumens). COEFFICIENTS OF UTILIZATION Effective Floor Cavity Reflectance 20% ROOM CAVITY RATIO Eff. Ceil. Wall 1 2 3 4 7 8 9 10 80* 50* 30* 10* .759 .716 .678 .642 .578 .524 .555 .481 .423 .484 .407 .348 .420 .372 .342 .295 .284 .240 .332 .257 .204 .296 .224 .174 .265 .195 .148 .240 .174 .129 70* 50* 30* 10* .737 .699 .663 .623 .565 .515 .539 .471 .417 .471 .399 .344 .409 .362 .336 .290 .281 .237 .323 .253 .202 .289 .220 .172 .258 .192 .147 .235 .171 .128 50* 50* 30* 10* .697 .665 .636 .589 .540 .497 .510 .452 .405 .446 .384 .335 .388 .344 .324 .280 .274 .232 .308 .244 .198 .275 .213 .169 .246 .186 .144 .224 .166 .126 30* 50* 30* 10* .660 .634 .610 .558 .516 .480 .483 .434 .393 .423 .370 .326 .368 .327 .312 .270 .268 .227 .293 .236 .194 .262 .206 .166 .235 .180 .141 .214 .161 .123 10* 50* 30* 10* .626 .605 .586 .529 .494 .464 .458 .417 .382 .402 .356 .318 .350 .311 .301 .261 .262 .222 .279 .229 .190 .250 .200 .162 .225 .175 .138 .205 .156 .121 0* 0* .565 .443 .361 .298 .242 .204 .173 .146 .122 .106 9258 3 F F 2 50° 5 6 1 *Percent Reflectance A B 0 C D E 1350 ISOFOOTCANDLE CHART: Footcandle Values for Isofootcandle Lines -1 Mtg. Hgt. A B C D E F 10' 12' 16' 20' 25' 10.00 6.94 3.91 2.50 1.60 5.00 3.47 1.95 1.25 0.80 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 0.20 0.14 0.08 0.05 0.03 -2 40° F -3 -3 10° 1800 20° 150° 160° 170° 180° 170° 160° 150° 140° 130° CANDLEPOWER DISTRIBUTION (IN CANDELAS) 120° 120° 110° 110° 100° 100° 90° 90° 80° 80° 525 SIDE 0 1 2 3 Isofootcandle chart shows illuminance in footcandles at ground level. LUMINAIRE WITH GLOBE AND RA739 (30° ANGLE) REFLECTOR DMVIG165G LAMP: 165W INDUCTION 130° 70° -1 RATIO OF DISTANCE TO MOUNTING HEIGHT 30° 165 WATT INDUCTION 140° F -2 70° BACK 1050 60° 60° CANDELAS Verticle Angle 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 ZONAL LUMENS Front Side Back 1680 1771 1990 2110 2133 2147 2160 2125 2003 1810 1682 1513 1097 593 164 7 0 3 2 3 3 1680 1685 1738 1736 1683 1576 1488 1303 921 479 282 143 15 11 13 12 10 5 5 5 3 1680 1616 1551 1385 1235 930 476 125 9 6 10 11 11 14 24 24 16 6 3 2 3 With Zone 0 – 10 10 – 20 20 – 30 30 – 40 40 – 50 50 – 60 60 – 70 70 – 80 80 – 90 90 – 100 100 – 110 110 – 120 120 – 130 130 – 140 140 – 150 150 – 160 160 – 170 170 – 180 Total Lumens 161 496 803 1048 1212 1250 1158 990 785 552 321 135 35 10 6 2 1 0 Note: Photometric data was developed using a 165W induction lamp (12,000 lumens). COEFFICIENTS OF UTILIZATION Effective Floor Cavity Reflectance 20% ROOM CAVITY RATIO Eff. Ceil. Wall 1 2 3 4 7 8 9 10 80* 50* 30* 10* .725 .685 .649 .618 .559 .508 .538 .469 .415 .471 .399 .345 .412 .365 .339 .293 .285 .242 .326 .256 .207 .291 .223 .177 .261 .195 .151 .237 .174 .132 70* 50* 30* 10* .699 .663 .630 .596 .541 .495 .519 .456 .406 .455 .389 .337 .398 .353 .330 .286 .279 .237 .315 .250 .203 .282 .218 .173 .252 .190 .148 .229 .170 .130 50* 50* 30* 10* .650 .621 .594 .554 .509 .470 .483 .430 .387 .424 .368 .323 .371 .330 .313 .271 .268 .228 .295 .237 .195 .264 .208 .167 .237 .181 .143 .216 .162 .125 30* 50* 30* 10* .606 .582 .560 .516 .479 .446 .450 .406 .369 .396 .348 .309 .347 .309 .296 .258 .256 .219 .277 .226 .188 .248 .197 .160 .222 .173 .137 .203 .154 .120 10* 50* 30* 10* .564 .545 .527 .480 .450 .423 .419 .383 .351 .370 .329 .295 .324 .289 .280 .244 .246 .210 .259 .214 .180 .232 .188 .154 .209 .164 .132 .190 .147 .115 0* 0* .505 .400 .330 .275 .226 .191 .163 .138 .116 .101 8967 3 1575 50° 50° FRONT 2 40° 40° *Percent Reflectance A B 0 C D E 2625 ISOFOOTCANDLE CHART: Footcandle Values for Isofootcandle Lines -1 3150 F -2 30° 30° -3 -3 3675 10° 6 1 2100 20° 5 0° 10° 20° -2 -1 0 1 2 RATIO OF DISTANCE TO MOUNTING HEIGHT 3 Mtg. Hgt. A B C D E 10' 12' 16' 20' 25' 10.00 6.94 3.91 2.50 1.60 5.00 3.47 1.95 1.25 0.80 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 F 0.20 0.14 0.08 0.05 0.03 Isofootcandle chart shows illuminance in footcandles at ground level. Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our ® Luxicon Lighting Layout Software are available to download. 9 CHAMP Induction ® Family Tree DMV FAMILY TREE: COVERS: PENDANT WALL QUAD—MOUNT APM2 3/4 IN. APM3 1 IN. HPM2 3/4 IN. TWM2 3/4 IN. TWM3 1 IN. QM25 3/4 IN. STANCHION CEILING 3/4 IN. CM2 CM3 1 IN. JM5 1 1/2 IN. PM5 1 1/2 IN. HOUSING DMV GLOBE G303 G303 S808 REFLECTOR/LENS GRD4 REFRACTOR GR302 GR305 PGR302 PGR305 GUARD P33 10 REFLECTOR RA79 RA739 RD79 RD739 Family Tree VMV FAMILY TREE: PHOTOCELL COVERS: PENDANT WALL APM2 3/4 IN. APM3 1 IN. HPM2 3/4 IN. TWM2 3/4 IN. TWM3 1 IN. CEILING V2PC20 V2PC22 V2PC27 QUAD—MOUNT QM25 3/4 IN. STANCHION 3/4 IN. CM2 CM3 1 IN. JM5 1 1/2 IN. PM5 1 1/2 IN. BALLAST HOUSING VMV REFRACTORS R2 R5 GLOBE REFRACTORS G241 G245 GUARD P23 GLOBES G24 G24 S808 GUARD P21 REFLECTOR RD70 RA70 GUARD P241 11 VMVIG and DMVIG Series CHAMP Induction ® Luminaires with Induction Lighting System Distributed by: For more information: If further assistance is required, please contact an authorized Cooper Crouse-Hinds Distributor, Sales Office or Customer Service Department: In the U.S.: In Australia: Cooper Crouse-Hinds P.O. Box 4999 Syracuse, NY 13221 Toll Free: 866-764-5454 (315) 477-5531 FAX: (315) 477-5179 crouse.customerctr@crouse-hinds.com Cooper Electrical Australia 61-29-743-7000 FAX: 61-29-743-7069 sales@cooperelectrical.com.au In Canada: Cooper Crouse-Hinds Canada Toll Free: 800-265-0502 (905) 507-4187 FAX: (905) 568-7048 In Mexico: Cooper Crouse-Hinds, S.A. de C.V. 52-555-804-4000 FAX: 52-555-804-4020 In Asia (Singapore): Cooper Crouse-Hinds Pte. Ltd. 65-6297-4849 FAX: 65-6297-4819 sales@cchspore.com.sg In Middle East (Dubai): CEAG Middle East LLC 971-4-324-1519 FAX: 971-4-324-1640 In India: In Latin America/Caribbean: Cooper Crouse-Hinds India 91-22-5604-5150 FAX: 91-22-2404-1811 Cooper Crouse-Hinds (954) 764-3853 FAX: (954) 764-3854 For the latest in new products and services, visit our website at: www.crouse-hinds.com In Europe (Germany): Cooper Crouse-Hinds GmbH 49-6271-806500 FAX: 49-6271-806476 Solutions.Worldwide.TM 4829-1206 Crouse-Hinds is a registered trademark of Cooper Industries, Inc. © 2006 Cooper Industries, Inc. Printed in U.S.A