Apparatus Section A Innovative, intelligent NEC and IEC solutions safely and efficiently control power and protect circuits in explosive, wet, and corrosive environments worldwide. New Products in the Apparatus Product Line Section • SynergEX Panelboards • EID Disconnect Assembly (Fused) • XDT Explosionproof Dry-Type Transformers 1A 2A 4A Notable changes to the Apparatus section of this catalog • Surge Protection Devices (previously section 4A) has been removed. For information on surge protection, please visit Eaton's Crouse-Hinds MTL Instruments at www.mtl-inst.com • New Section 4A for transformers Apparatus A Table of Contents Section A of the Eaton's Crouse-Hinds catalog contains the following product groupings: Section 1A Panelboards (for use in hazardous and non-hazardous areas) For central control and protection of a large number of feeder or branch circuits and for housing of circuit breakers. D2L XLPB D2PB EXD D2D GUSC EPL D2Z LP N2PB SPB NLP Section 2A Switches A (for use in hazardous and non-hazardous areas) Switches and enclosures for disconnecting motor, lighting and other circuits. EDS, EDSC NST FSPC EFD, EFDC NRS GUSC FLS 6810 Series WST EID 7810 Series GHG N2RS EBM Section 3A Instrument Housings (for use in hazardous areas) Housings for a variety of types and makes of meters and instruments, thermostats, heaters and clocks. HRC ETW TCH ETC EXH ETR XC D2TW Section 4A Transformers Provide safe and efficient electric power distribution in the most extreme harsh and hazardous locations. XDT 624 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1A Panelboards Hazardous and Non-hazardous Description Page No. General Information see page 626 Application/Selection see page 627 Wiring Diagrams see page 628 Hazardous Location Panelboards see page 641 see page 634 see pages 650–653 see page 630 see pages 667–668 see page 641 see page 634 see page 630 see page 663 see pages 669–671 see pages 667–668 see page 654 Ordinary Location XLPB NLP Series www.crouse-hinds.com US: 1-866-764-5454 see page 672 see page 675 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 625 1A Division 1 and 2 PowerPlus™ EXD PowerPlus™ EPL SynergEX SPB Exactra™ LP GUSC Division 2 PowerPlus™ D2D PowerPlus™ D2L Exactra™ LP D2PB N2PB GUSC D2Z 1A Circuit Breaker Panelboards General Information Applications: Ratings Circuit breaker panelboards are used in hazardous and non-hazardous areas (as shown in the individual listings): • To provide, in one compact unit, a centrally controlled switching system for a large number of feeder or branch circuits • For controlling lighting, heating, appliance, heat tracing, motor and similar circuits • In locations where rough usage, moisture, dust, dirt and corrosion are a problem • To house thermal-magnetic circuit breakers that provide disconnect means, short circuit protection and thermal time delay overload protection Single and two-pole, W-C-375a, Class 1a 120 / 240 VAC Two and three-pole, W-C-375a, Class 1b 240 VAC 1A Features: Panelboards: • All main and branch circuit wire lugs are solderless and readily accessible for fast, easy installation • Are factory wired from main terminal blocks or main bus to line side of branch circuit breakers • With circuit breakers in factory sealed housings (LP1, EXD and EPL), are also factory wired from the load side of branch circuit breakers to readily accessible terminal blocks • With circuit breakers grouped in one enclosure (LP2, D2D, D2L, D2Z and D2PB factory sealed), branch circuit wires are attached directly to circuit breaker load terminals Circuit breakers (thermal magnetic): • Are trip-free of the handles and cannot be held closed under short circuit or overload conditions • Four breaker types are used in panelboards manufactured by Eaton's Crouse-Hinds. They are as follows: • Quicklag® – used in LP, D2PB, EPL and D2L panelboards; 10,000 ampere symmetrical interrupting capacity Fed. Spec. Standard Materials, Finishes, Options and Compliances: • See individual listing pages • EHD/FDB frame – used in EXD and D2D panelboards; 14,000 ampere symmetrical interrupting capacity - 480 VAC Ratings Fed. Spec. Single-pole, 277 VAC W-C-375a, Class 2a or 125 VDC Two and three-pole N/A 480 VAC or 250 VDC Wiring Systems: • See pages 628 and 629 for wiring diagrams. These are the standard systems used for single and three-phase panelboards having single, two and three-pole circuit breakers • Standard panelboards are listed with all circuit breakers having the same number of poles and wired for one of these systems • To meet the requirements of a specific installation, panelboards can be assembled with a combination of single, two and three-pole breakers. To accomplish this, the three individual wiring systems must have the same main service as, for example, 3-phase, 4-wire, solid neutral. Panelboard Type Applicable Wiring Systems D2PB 3, 4, 5, 8, 11, 12 • Diagrams show only four, six or eight circuits; are intended to show only the phase connections of each circuit breaker and do not necessarily show their physical location in a panelboard. Panelboards are available with the number of circuits indicated in the listings. Quicklag is a registered trademark of Cutler-Hammer Inc. 626 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1A Circuit Breaker Panelboards Quick Selector Chart Quick Selector Chart Panelboard D2D NEC & NEMA Certifications and Compliances Cl. I, Div. 2, Groups B, C, D NEMA: 3, 4, 7BCD, 12 Factory Sealed Yes Number Circuits Max. 42 Breaker Frame Size Various Multi-Pole Voltage Max. 600VAC 250VDC Trip Rating Amps Max. 100 Circuit Interrupting Amps Max. 10,000 Step Down Transformer Available Yes Cl. I, Div. 2, Groups B, C, D NEMA: 3, 4, 7BCD, 12 Yes 42 Quicklag® 240VAC 125VDC 100 10,000 Yes D2PB Cl. I, Div. 2, Groups C, D NEMA: 3, 7CD (Div. 2), 12 Yes 24 Quicklag® 240VAC 30 10,000 Yes D2Z Cl. I, Zone 1, Div. 2, Groups A, B, C, D NEMA: 3, 4X, 7ABCD (Div. 2), 12 Corrosion Resistant, Non-Metallic Yes 54 CEAG 480VAC 180 10,000 No EPL Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA: 3, 4, 7BCD, 9EFG, 12 Yes 42 Quicklag® 240VAC 125VDC 100 10,000 No EXD Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA: 3, 4, 7BCD, 9EFG, 12 Yes 42 Various 600VAC 250VDC 100 10,000 No GUSC Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA: 3, 7CD, 9EFG, 12 No 2 Quicklag® 240VAC 30 10,000 No LP1 Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA: 3, 4X, 7BCD, 9EFG, 12 Yes 36 Quicklag® 240VAC 100 10,000 No LP2 Cl. I, Div. 2, Groups B, C, D Cl. II, Div. 2, Groups F, G Cl. III NEMA: 3, 4X, 7BCD, 9EFG, 12 Yes 36 Quicklag® 240VAC 100 10,000 Yes N2PB Cl. I, Div. 2, Groups C, D Cl. II, Div. 2, Groups F, G NEMA: 3, 7CD, (Div. 2), 12 Corrosion Resistant, Non-Metallic Yes 24 Quicklag® 240VAC 30 10,000 No NLP NEMA 3, 12 No 30 QO/Qwik-Guard® 240VAC 100 10,000 No SPB Class I, Zone 1 Cl. I, Div. 2, Groups A, B, C, D Cl. II, Div. 1, Groups E, F, G Yes 60 Various 480VAC 40 10,000 No XLPB NEMA 1, 3, 3R, 4, 4X, 12 No 42 Various 600VAC 100 10,000 Yes 1A D2L Quicklag is a registered trademark of Cutler-Hammer Inc. QO/Qwik-Guard is a registered trademark of Square D. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 627 1A Circuit Breaker Panelboards Wiring Diagrams D2PB Panelboards System 3 Mains—3-Wire Branches—3-Wire Breakers—2-Pole Solid Neutral System 4 Mains—3-Wire Branches—2-Wire Breakers—Single-Pole Solid Neutral System 5 Mains—4-Wire, 3-Phase Branches—2-Wire, 1-Phase Breakers—Single-Pole Solid Neutral System 7 Mains—2-Wire Branches—2-Wire Breakers—Single-Pole Solid Neutral System 8 Mains—4-Wire, 3-Phase Branches—3-Wire, 1-Phase Breakers—2-Pole Solid Neutral System 13 Mains—4-Wire, 3-Phase Branches—2-Wire, 1-Phase Breakers—2-Pole System 15 Mains—4-Wire, 3-Phase Branches—3-Wire, 1-Phase Breakers—Single-Pole Solid Neutral System 24 Mains—3-Wire Branches—2-Wire Breakers—Single-Pole Solid Neutral System 25 Mains—4-Wire, 3-Phase Branches—2-Wire, 1-Phase Breakers—Single-Pole Solid Neutral System 28 Mains—4-Wire, 3-Phase Branches—3-Wire, 1-Phase Breakers—2-Pole Solid Neutral System 29 Mains—3-Wire, 3-Phase Branches—2-Wire, 1-Phase Breakers—2-Pole 1A System 1 Mains—2-Wire Branches—2-Wire Breakers—2-Pole 628 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1A PowerPlus™ Lighting Panelboards Wiring Diagrams PowerPlus™ Power Panelboards 1A Single Phase Circuit Three Phase Circuit PowerPlus™ Lighting Panelboards Single Phase Circuit www.crouse-hinds.com Three Phase Circuit US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 629 1A Cl. I, Div. 1 & 2, Groups B†, C, D Cl. II, Div. 1, Groups E†, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4*, 4X§, 7B†CD, 9EFG, 12 Exactra™ Panelboards Lighting and Heat Tracing LP1 Series LP2 Series (Div. 2) Exactra™ Factory-Sealed Lighting Panelboards provide flexibility and labor savings when installed, and for future changes in the field. Panels are prewired to maximum circuit capacity and ratings. 1A Applications: Exactra™ Factory-Sealed Lighting Panelboards are ideal: • In areas made hazardous by the presence of flammable gases and vapors, and combustible dusts • In areas subject to weather, dampness, and corrosion • For branch power distribution and circuit protection for motors, valves, pumps, lighting, heat tracing, receptacles, etc. • For indoor and outdoor applications in petroleum refineries, chemical and petrochemical plants, and other process industry facilities where similar hazards exist • In areas where flammable vapors or gases or highly combustible dusts may be present due to accidental or abnormal conditions • To accommodate up to 35 amp branch loads Features and Benefits: • Factory sealed, no external seals required for branch circuits. External seals are required for Class I, Div. 1 applications • Fully wired for circuit breaker housing to pre-numbered terminals in wiring compartment • External flange design allows wide unobstructed cover opening for easy wiring access • External circuit breaker handles can be padlocked "ON" or "OFF" • Furnished with two 3" and ten 11/2" conduit openings • Breather and drains available for each enclosure • Available with or without main circuit breaker up to 100 amps • Isolated neutral and ground bar provided • Available with up to 6 GFI and/or EPD branch breakers per panel. GFI and EPD branch breakers available within the same panel • Available with ambient compensated breakers throughout panelboard • Stainless steel hinges allow the cover to swing wide open or be removed • Stainless steel hex head bolts captive design prevents lost bolts • Cast copper-free (less than 0.4%) aluminum construction for excellent corrosion resistance • Neoprene cover gasket meets NEMA 4 / CSA Enc. 4 / IP65 requirements, provides watertight seal for superior water and corrosion protection • Copper bus bar system 630 www.crouse-hinds.com US: 1-866-764-5454 CSA Enc. 3, 4*, 5 Explosionproof Dust-Ignitionproof Factory Sealed‡ Wet Locations Watertight Certifications and Compliances: LP1 panelboards • • • • • • • • • Class I, Groups B, C, D Class I, Zone 1 & 2, IIB + H2 Class II, Groups E, F, G Class III NEMA 3, 4*, 4X§, 7B†CD, 9E†FG, 12 CSA Enc. 3, 4*, 5 IP65* Enclosure UL Classified (Standard 1203) cUL Classified (Certified by UL to CSA C22.2 No. 30) LP2 Panelboards • • • • • • • • • Class I, Division 2, Groups B†, C, D Class I, Zone 1 & 2, IIB + H2 Class II, Division 2, Groups F, G Class III NEMA 3, 4*, 4X§, 7BCD (Div 2), 9EFG, 12 CSA Enc. 3, 4*, 5 IP65* Enclosure UL Classified (Standard 1203) cUL Classified (Certified by UL to CSA C22.2 No. 30) Standard Materials: • Body and cover – cast copper-free aluminum • Gasket – neoprene • Operating handles – extruded aluminum (copper-free) • Operating shafts, cover bolts, washers, GFI/EPD plungers and hinges – stainless steel • Circuit breaker operator forks – - for 1 pole standard breakers - die-cast aluminum (copper-free) - for 1 and 2 pole GFI / EPD breakers die-cast aluminum (copper-free) - for 2 and 3 pole standard breakers stainless steel • Lifting bracket – cold rolled steel • Bus bar – copper Standard Finishes: • Aluminum – natural • Stainless steel – natural • Cold rolled steel – electrogalvanized * NEMA 4/CSA Enc. 4/IP65 hosetight with breather and drain openings plugged. † With suffix -GB. ‡ External seals required for Class I, Div. 1. § NEMA 4X when ordered with suffix S752 with breather and drain openings plugged. CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business LP1 Lighting Panelboard Exactra™ Panelboards Cl. I, Div. 1 & 2, Groups B†, C, D Cl. II, Div. 1, Groups E†, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4*, 4X§, 7B†CD, 9EFG, 12 Lighting and Heat Tracing LP1 Series LP2 Series (Div. 2) 1A CSA Enc. 3, 4*, 5 Explosionproof Dust-Ignitionproof Factory Sealed‡ Wet Locations Watertight Electrical Ratings: Options: Breaker Options: Branch Breaker (120 / 240 VAC Quicklag® Bolt On) Trip Ratings • 1, 2, 3 pole 10, 15, 20, 25, 30, 35 amp • GFI type 1, 2-pole (5 mA sensitivity) 15, 20, 25, 30 amp • EPD type 1, 2-pole (30 mA sensitivity) 15, 20, 25, 30 amp Main Breaker Trip Ratings: • Size B & C 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80, 90, 100 amp 2, 3-pole Main Lugs • Size B & C 100 amp Description Suffix • Alternate feed: incoming power into terminal enclosure from bottom . . . . . . . . . . . . . . . . . . . . . A • Group B and E suitability (10A not avail.) . . . . . . . . . . . . . . . GB • Lamicoid nameplate with customer-specified panel identification . . . . . . . . . . . . . . . . . LID • Stainless steel nameplate with customer-specified panel identification . . . . . . . . . . . . . . . . . SID • 125W@120 VAC, 250W@240 VAC internal space heater in circuit breaker enclosure . . . . . . . . . . . . . R22 • External epoxy powder coat finish . . . . . . . . . . . . . . . . . . . S752 • Internal and external epoxy powder coat finish . . . . . . . . . . . . S753 • One breather and two drains per enclosure . . . . . . . . . . . . . . . . . . . S756V • All conduit entries plugged with PLG recessed head plugs . . . . . . S822 • All conduit entries plugged with square headed plugs . . . . . . . . . . S872 • To order an inverted panelboard with all conduit openings for power and branch circuits on the bottom (inverted) . . . . . . . . . . . . . . I Description Suffix • EPD branch breaker (up to 6 EPD and/or GFI per panel) . . . . . . . . . . . E • GFI branch breaker (up to 6 EPD and/or GFI per panel) . . . . . . . . . . . G • Ambient compensated (50°C) breakers throughout panelboard . . V • HID branch breaker for lighting loads . . . . . . . . . . . . . . . . . . . . . . . . H Weight • 150 lbs. In Inches: Description Cat. # • Extra circuit breaker operator assemblies 1-pole (qty. 3) . . . . . . • Replacement cover plugs for unused circuit breaker positions (qty. 6). . . . . . . . . . . . . . . . . . . . . . • Extra circuit breaker operator assemblies for 1 pole and 2 pole GFI/EPD breakers (qty. 3). . . . . . . • GFI/EPD "push to test" plungers (qty. 6). . . . . . . . . . . . . . . . . . . . . . • GFI/EPD entry plugs (qty. 6). . . . . • Replacement mounting feet (qty. 2). . . . . . . . . . . . . . . . . . . . . . • Extra circuit breaker operator assembies for 2 pole standard and GFI/EPD breakers . . . . . . . . . • Extra circuit breaker operator assembies for 3 pole breakers. . . LP K1 LP K2 LP K3 LP K4 LP K5 LP K6 LP K7 LP K8 Panel Capacity: Panel Size With Main With Main Breaker Lug Only 2-pole 3-pole Available w/GFI, Main EPD Breaker Branch Max. Amp Protection B C 24 36 100 100 Max. No. of Branch Spaces 22 34 21 33 Yes Yes * NEMA 4/CSA Enc. 4/IP65 hosetight with breather and drain openings plugged. † With suffix -GB. ‡ External seals required for Class I, Div. 1. § NEMA 4X when ordered with suffix S752 with breather and drain openings plugged. Quicklag® is a registered trademark of Cutler-Hammer Inc. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 631 1A Dimensions Lighting Panelboard Accessories: Exactra™ Panelboards 1A Cl. I, Div. 1 & 2, Groups B†, C, D Cl. II, Div. 1, Groups E†, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4*, 4X§, 7B†CD, 9EFG, 12 Lighting and Heat Tracing LP1 Series LP2 Series (Div. 2) Ordering Information 1. LP1 & LP2 Factory Sealed 120 / 240 Volt Lighting Panelboards 1A Division 1 Division 2 Branch Spaces Needed 1 Phase 3 Wire 3 Phase 4 Wire 1 Phase 3 Wire 3 Phase 4 Wire 6 8 10 12 14 16 18 20 20 22 22 24† 24 26 28 30 32 34 36† Breaker Ready■ (Empty) LP1B106 LP1B108 LP1B110 LP1B112 LP1B114 LP1B116 LP1B118 LP1B120 LP1C120 LP1B122 LP1C122 LP1B124† LP1C124 LP1C126 LP1C128 LP1C130 LP1C132 LP1C134 LP1C136† LP1B100 LP1C100 LP1B306 LP1B308 LP1B310 LP1B312 LP1B314 LP1B316 LP1B318 LP1B320 LP1C320 LP1B322 LP1C322 LP1B324† LP1C324 LP1C326 LP1C328 LP1C330 LP1C332 LP1C334 LP1C336† LP1B300 LP1C300 LP2B106 LP2B108 LP2B110 LP2B112 LP2B114 LP2B116 LP2B118 LP2B120 LP2C120 LP2B122 LP2C122 LP2B124† LP2C124 LP2C126 LP2C128 LP2C130 LP2C132 LP2C134 LP2C136† LP2B100 LP2C100 LP2B306 LP2B308 LP2B310 LP2B312 LP2B314 LP2B316 LP2B318 LP2B320 LP2C320 LP2B322 LP2C322 LP2B324† LP2C324 LP2C326 LP2C328 LP2C330 LP2C332 LP2C334 LP2C336† LP2B300 LP2C300 2. † Items are not available with main circuit breaker. ■ Provided for main lug only; main breaker must be specified with amperage. Catalog Number Example: Lighting Panelboards can be furnished with an assortment of breaker ratings and pole configurations. Assortments may be ordered by adding the number of poles and amp rating designations to the catalog number. Example: A three-phase, Class I, Div. 2, Groups C, D lighting panelboard with: • 5 three-pole breakers – with 15 amp rating • 6 single-pole breakers – with 20 amp GFI personnel protection • Three-pole main breaker – with 100 amp rating • Alternate feed option • Breather and drain option 3. 4. Select basic panelboard catalog number from listing: • Determine phase (available with single-phase or three-phase wiring). • Determine a total even number of breaker spaces needed to complete your desired lighting panelboard. Note: 3 breaker spaces = Three-pole breaker 2 breaker spaces = Two-pole breaker 2 breaker spaces = Two-pole GFI (or EPD) breaker 1 breaker space = Single-pole breaker 1 breaker space = Single-pole GFI (or EPD) breaker • Review Panel Capacity table see page 631 • If GFI or EPD breakers are to be included insert "G", "E" or "EG" after base catalog number (e.g., LP2B316G). • Maximum number of GFI and/or EPD breaker spaces is 6 per panel. (e.g. 6 single-pole or 3 two-pole). For more, consult factory. • If ambient compensated breakers are required, insert "V" (e.g. LP2B318GV). Using three-pole branch breakers first, select circuit breakers for lighting panel board application: • Place an asterisk (*) before each quantity of circuit breakers • First insert the quantity of breakers needed. • Second insert the quantity of poles (start with three-pole breakers). Note: Single-phase panelboards can have single- or two-pole breakers. Three-phase panelboards can have single, two- or three-pole breakers. • Third insert the ampere rating needed (start with highest ampere rating). • Insert "G" for GFI or "E" for EPD type breakers, if desired. For additional circuit breakers repeat step 2. If there are more three-poles with different amp ratings, then continue with threepole designations. Otherwise continue with two-pole circuit breakers, and then single-pole breakers. To add a main breaker, insert a space, the number of poles (2 or 3), an "M" to indicate main breaker, then indicate the amp rating (See "ratings" for trip ratings available). If no main breaker is specified, the panelboard will have main lugs. No suffix needed in catalog number for main lug only. For future spaces, to provide for operating mechanism without breaker write 00 (e.g. one three-pole mechanism without breaker: 01300). Unused breaker positions without designations will be blanked and plugged. Complete panel will be provided for future breaker installations. * NEMA 4/CSA Enc. 4/IP65 hosetight without suffix S756V. ‡ External seals required for Class I, Div. 1. § NEMA 4X when ordered with suffix S752 without suffix S756V. †With suffix -GB. 632 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 CSA Enc. 3, 4*, 5 Explosionproof Dust-Ignitionproof Factory Sealed‡ Wet Locations Watertight Copyright© 2013 Eaton’s Crouse-Hinds Business Exactra™ Panelboards Lighting and Heat Tracing LP1 Series LP2 Series (Div. 2) Cl. I, Div. 1 & 2, Groups B†, C, D Cl. II, Div. 1, Groups E†, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4*, 4X§, 7B†CD, 9EFG, 12 CSA Enc. 3, 4*, 5 Explosionproof Dust-Ignitionproof Factory Sealed‡ Wet Locations Watertight 1A Wiring Diagrams: 1A * NEMA 4/CSA Enc. 4/IP65 hosetight without suffix S756V. ‡ External seals required for Class I, Div. 1. § NEMA 4X when ordered with suffix S752 without suffix S756V. †With suffix -GB. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 633 1A PowerPlus™ Panelboards Lighting and Heat Tracing EPL Series (Div. 1 & 2) D2L Series (Div. 2) EPL Series: Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Zone 1 & 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 D2L Series: Cl. I, Div. 2, Groups B†, C, D Cl. I, Zone 2, IIB + H2† Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 PowerPlus™ Series Panelboards provide both premium factory-sealed and value non-factory-sealed solutions for the protection and distribution of lighting, power, and heat tracing circuits. This panel solution is designed, engineered, and manufactured to be the industry’s safest and most dependable panelboard for hazardous area locations. 1A PowerPlus Premium and Value Solutions • Premium Solution: PowerPlus factorysealed panelboards are premium panelboards that provide maximum circuit flexibility with labor savings during installation, operation, and maintenance, and are accommodating for future changes in the field (order with either “S” or “A” in base part number). Panels are pre-wired to maximum circuit capacity, allowing for easy and safe replacement or installation of components in the field, while maintaining factory-sealed integrity. • Value Solution: PowerPlus non-factorysealed panelboards are value panelboards that offer maximum circuit flexibility and many of the same features and benefits of the PowerPlus premium line. This value solution is provided without terminal housing and factory wiring of circuits (order with “N” in base part number). The non-factory-sealed solution reduces initial panelboard material costs and requires field wiring to circuit breakers and external seals to be field-installed during installation. Applications: EPL and D2L PowerPlus™ panelboards are used: • In areas made hazardous by the continuous or abnormal presence of flammable gases, vapors, and combustible dusts • In areas subject to weather, dampness, and corrosion • For branch power distribution and circuit protection to motors, valves, pumps, lighting, heat tracing, receptacles, etc. • For indoor and outdoor applications in petroleum refineries, chemical and petrochemical plants, and other process industry facilities where similar hazards exist • To accommodate up to 100 amp branch loads (only 3 circuits), balance is up to 50 amps Certifications and Compliances: Standard Materials and Finishes: EPL Series: • Circuit breaker enclosure body and cover – copper-free aluminum • Terminal housing – type 316L stainless steel ("S") or copper-free aluminum ("A") • Gasket – neoprene (cast aluminum enclosure); foam-in-place (stainless steel enclosure) • Operating handles – copper-free aluminum • Operating shafts and bushings, cover bolts, washers, hinges, breather/drain, retractile springs – stainless steel • Circuit breaker operators – non-metallic • Lifting bracket – electrogalvanized cold rolled steel • Chassis – silver-plated copper • Breather cap – Delrin® non-metallic material • Neutral and ground bar – tin-plated aluminum • NEC/CEC: Class I, Division 1 & 2, Groups B†, C, D Class I, Zone 1 & 2, IIB + H2† Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III • NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 9EFG, 12 • CSA Enc. 3, 4, 5 • UL Standard: 67, 1203 • cUL (to CSA Standard C22.2 Nos. 29 & 30) • IP65 D2L Series (Division 2): • NEC/CEC: Class I, Division 2, Groups B†, C, D Class I, Zone 2, IIB + H2† Class II, Division 2, Groups F, G Class III • NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 • CSA Enc. 3, 4, 5 • UL Standard: 67, 1203 • cUL (to CSA Standard C22.2 Nos. 29 & 30) • IP65 † Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit, order EPL-GB-KIT separately. ‡ NEMA 4X rating is available when ordered with suffix S752 or S753. Delrin® is a registered trademark of DuPont. 634 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business PowerPlus™ Panelboards Lighting and Heat Tracing EPL Series (Div. 1 & 2) D2L Series (Div. 2) EPL Series: Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Zone 1 & 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 D2L Series: Cl. I, Div. 2, Groups B†, C, D Cl. I, Zone 2, IIB + H2† Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 1A 1A † Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit, order EPL-GB-KIT separately. ‡ NEMA 4X rating is available when ordered with suffix S752 or S753. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 635 1A PowerPlus™ Panelboards D2L Series: Cl. I, Div. 2, Groups B†, C, D Cl. I, Zone 2, IIB + H2† Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 1A Lighting and Heat Tracing EPL Series (Div. 1 & 2) D2L Series (Div. 2) EPL Series: Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Zone 1 & 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 † Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit, order EPL-GB-KIT separately. ‡ NEMA 4X rating is available when ordered with suffix S752 or S753. 636 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business PowerPlus™ Panelboards Lighting and Heat Tracing EPL Series (Div. 1 & 2) D2L Series (Div. 2) EPL Series: Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Zone 1 & 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 Electrical Ratings: Accessories: Branch Breakers (120/240VAC Quicklag® Bolt-On) Trip Ratings: Gland Plates D2L Series: Cl. I, Div. 2, Groups B†, C, D Cl. I, Zone 2, IIB + H2† Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 1A Field installable gland plates with factory-provided aluminum Myers™ Hubs for the D2L stainless steel terminal housing (one 3-inch hub and 12 branch entry hubs - size dependent upon suffix, each kit includes 3 gland plates, 1 for the top or bottom and 1 for each side): Part Number 3 /4" branch entry hub D2L HUB2 KIT 1" branch entry hub D2L HUB3 KIT 1 1/2" branch entry hub D2L HUB5 KIT Replacement gland plate (no hubs) D2L HUB0 KIT • 1-, 2-, and 3-pole • 10, 15, 20, 25, 30, 35, 40, 45, 50 amp (available in all breaker spaces in panel), 55, 60, 70, 80, 90, 100 amp (only 3 breaker spaces available for 55 to 100 amp branch breakers) • GFI type, 1- and 2-pole (5mA sensitivity) 15, 20, 25, 30, 40 (50 amp - available 2-pole only) • EPD type, 1- and 2-pole (30mA sensitivity) 15, 20, 25, 30, 40 (50 amp - available 2-pole only) • HID type, 1- and 2-pole, 15, 20, 25, 30, 35, 40, 50, 60 • Available with GFI, EPD, or a combination of both in one panel with a 21-position electrical test circuit • Ambient compensated breakers available to +50°C Circuit Breaker Operator Assemblies: Operator Assemblies D2L/EPL 1-pole or 3-pole breakers D2L/EPL 2-pole breakers Main Breaker Trip Ratings: Part Number EPL HDL13 EPL HDL2 Replacement Cover Plugs: • 2- or 3-pole • Size B: 10 to 100 amps • Size C and D: 10 to 225 amps For unused circuit breaker positions (qty. 5): Plug Kits D2L/EPL Sizes B, C, D Main Lugs: • Size B, C, and F: 225 amps • Size D: not available; main breaker only Part Number EPL OP PLG Kit for Group B To add the following features to the panelboard, add a dash and then the suffix to the Cat. No. When multiple suffixes are needed, add them to the Cat. No. in alpha-numeric order. Description Suffix Space heater................................................................................. R22 Square head plugs on all conduit openings................................. SP Epoxy powder coat finish, external .............................................. S752 Epoxy powder coat finish, internal and external .......................... S753 Recess head plugs on all conduit openings ................................ RP Stainless steel breaker operator cover (ice shield)....................... HG Group B kit factory installed ......................................................... GB GFI breakers ................................................................................. G EPD breakers ................................................................................ E HID breakers ................................................................................. H Ambient compensated breakers (50ºC)........................................ V Lamacoid Nameplate.................................................................... LID D2L/EPL Stainless Steel Breaker Operator Cover To protect operators from ice build-up for all D2L/EPL PowerPlus panels: Kit for Size B panel Kit for Size C and D panel Part Number EPL-HG24-KIT EPL HG42-KIT Space Heater Kit D2L/EPL PowerPlus Panels EPL R22 KIT Terminal Housing Mounting Plate Kit: To adapt depth of terminal housing to same depth as breaker enclosure *** Panel Types / Sizes Part Number Terminal Housing D2L/EPL Sizes B, C, D EPLA-MTG-KIT Aluminum D2L Sizes B, C, D D2LS-MTG-KIT Stainless A standard panelboard has conduit openings for power and branch circuits on top. To order a panelboard with main power feed from the bottom of breaker housing, and branch entries on top (alternate) ........... -A** To order an inverted panelboard with all conduit openings for power and branch circuits on the bottom (inverted) .................... -I To order an inverted panelboard with main power feed on top and bottom (alternate inverted) .............................................. -A-I** † Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit, order EPL-GB-KIT separately. ‡ NEMA 4X rating is available when ordered with suffix S752 or S753. ** Not available in D2L/EPL Size D panels. *** The weight of the panel is sufficiently supported by mounting of breaker enclosure. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 637 1A Options: Standard panels less -GB suffix are applicable for Group B, but it is required to install brackets on breakers. Part Number To order brackets factory installed add suffix -GB For field installable kit EPL GB KIT PowerPlus™ Panelboards 1A Lighting and Heat Tracing EPL Series (Div. 1 & 2) D2L Series (Div. 2) EPL Series: Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Zone 1 & 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 D2L Series: Cl. I, Div. 2, Groups B†, C, D Cl. I, Zone 2, IIB + H2† Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 Table A – Panel Capacity Maximum Number of Breaker Spaces: Panel Size Max. No. of Branch Circuit Breaker Spaces With Main With Main Breaker Lug Only 2-pole 3-pole Available Main Breaker Ampacity Available With GFI, EPD Branch Protection B 24 C§ 42 D 42 Up to 100■ Up to 100■ 110 to 225✪ Up to 225✪ Yes Yes Yes Yes 22 40 36 42 21 39 36 42 Table B – To Size Panels with GFI or EPD Branch Breakers 1A Maximum Number of GFI or EPD Breakers Panel Size with Main Lug or Main SingleTwoBreaker Pole Pole B C D 12 (10 with 3-pole MCB, 11 with 2-pole MCB) 21 14 EPLDN only - can go up to 42 GFI or EPD circuits. EPLDN will accommodate up to 225 amp main breaker. 21 Each factory-sealed panel is equipped with 42 load wires for GFI/EPD breakers and any combination with standard branch breakers. Determine the total number of load wires required to complete your panel. You may not exceed 42 load wires. Load Wires Required Single-pole breaker 1 Single-pole GFI (or EPD) breaker 2 Two-pole breaker 2 Two-pole GFI (or EPD) breaker 3 Three-pole breaker 3 Maximum Total: 42 load wires (factory sealed) Maximum Total: 84 load EPLDN Panels wires (non-factory sealed) † Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit, order EPL-GB-KIT separately. ‡ NEMA 4X rating is available when ordered with suffix S752 or S753. § All size B and size C panels with main breaker rated up to 100 amps use a back-fed branch breaker. All size D and size C panels with main breaker rated from 110 amps to 225 amps have a dedicated location for main breaker. Size C ordered with suffix 2M00 or 3M00 are provided with 36 branch circuits for maximum breaker ampacity. ✪ Main breakers are mounted external to chassis. ■ Main breakers are chassis mounted and back-fed. 638 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business PowerPlus™ Panelboards Lighting and Heat Tracing EPL Series (Div. 1 & 2) D2L Series (Div. 2) EPL Series: Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Zone 1 & 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 D2L Series: Cl. I, Div. 2, Groups B†, C, D Cl. I, Zone 2, IIB + H2† Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 1A Lighting Panelboard Catalog Number Example Example: Class I, Division 2 / Zone 2, Group B panel with: • 240VAC lighting panelboard • (28) single-pole 20 amp branch breakers • (1) single-pole 15 amp branch GFI breaker • 225 amp 3-pole main circuit breaker 1A † Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit, order EPL-GB-KIT separately. ‡ NEMA 4X rating is available when ordered with suffix S752 or S753. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 639 1A PowerPlus™ Panelboards Lighting and Heat Tracing EPL Series (Div. 1 & 2) D2L Series (Div. 2) Dimensions Size B Panel* (With Stainless Steel Terminal Housing) EPL Series: Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Zone 1 & 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 Size C and D Panel* (With Cast Terminal Housing) 6.50 (165.1) 4.66 (118.4) 2.81 (71.4) 6.50 (165.1) 1-1/2" NPT 12 PLACES 1.83 (46.5) 20.12 (511.0) D2L Series: Cl. I, Div. 2, Groups B†, C, D Cl. I, Zone 2, IIB + H2† Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 4.66 (118.4) 2.81 (71.4) 5.10 3.51 (129.5) (89.2) TYP. TYP. .92 (23.4) 1/2" BOLT (M12) 1.31 (33.3)TYP. CL .50 (12.7) 3/8" BOLT (M9) 5.50 (139.7) 11.16 (283.5) 12.93 (328.4) APPROXIMATE 4.00 (101.6) 1A 11.52 (292.6) APPROXIMATE 3 1/2" NPT 3 1/2" NPT ALTERNATE FEED OPTION (SUFFIX 'A') ONLY 61.75 (1568.5) 48.63 (1235.2) 29.50 (749.3) 17.50 (444.5) 6.00 (152.4) 14.88 (377.8) TYP. 5.75 (146.0) 14.88 (377.8) TYP. † Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit, order EPL-GB-KIT separately. ‡ NEMA 4X rating is available when ordered with suffix S752 or S753. *Stainless steel and cast aluminum terminal housing for Sizes B, C, and D are the same. Note: Value series non-factory-sealed EPL*N panel dimensions are the breaker housing only and use standard entries shown on cast terminal housing. 640 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business EXD Series: Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Zone 1 & 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 PowerPlus™ Panelboards Power EXD Series (Div. 1 & 2) D2D Series (Div. 2) PowerPlus™ Series Panelboards provide both premium factory-sealed and value non-factory-sealed solutions for the protection and distribution of lighting, power, and heat tracing circuits. This panel solution is designed, engineered, and manufactured to be the industry’s safest and most dependable panelboard for hazardous area locations. PowerPlus Premium and Value Solutions Applications: EXD and D2D PowerPlus™ panelboards are used: • In areas made hazardous by the continuous or abnormal presence of flammable gases, vapors, and combustible dusts • In areas subject to weather, dampness, and corrosion • For branch power distribution and circuit protection to motors, valves, pumps, lighting, heat tracing, receptacles, etc. • For indoor and outdoor applications in petroleum refineries, chemical and petrochemical plants, and other process industry facilities where similar hazards exist • To accommodate up to 100 amp branch loads (only 3 circuits), balance is up to 50 amps 1A Certifications and Compliances: EXD Series: • NEC/CEC: Class I, Division 1 & 2, Groups B†, C, D Class I, Zone 1 & 2, IIB + H2† Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III • NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 9EFG, 12 • CSA Enc. 3, 4, 5 • UL Standard: 67, 1203 • cUL (to CSA Standard C22.2 Nos. 29 & 30) • IP65 D2D Series (Division 2): • NEC/CEC: Class I, Division 2, Groups B†, C, D Class I, Zone 2, IIB + H2† Class II, Division 2, Groups F, G Class III • NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 • CSA Enc. 3, 4, 5 • UL Standard: 67, 1203 • cUL (to CSA Standard C22.2 Nos. 29 & 30) • IP65 1A • Premium Solution: PowerPlus factorysealed panelboards are premium panelboards that provide maximum circuit flexibility with labor savings during installation, operation, and maintenance, and are accommodating for future changes in the field (order with either “S” or “A” in base part number). Panels are pre-wired to maximum circuit capacity, allowing for easy and safe replacement or installation of components in the field, while maintaining factory-sealed integrity. • Value Solution: PowerPlus non-factorysealed panelboards are value panelboards that offer maximum circuit flexibility and many of the same features and benefits of the PowerPlus premium line. This value solution is provided without terminal housing and factory wiring of circuits (order with “N” in base part number). The non-factory-sealed solution reduces initial panelboard material costs and requires field wiring to circuit breakers and external seals to be field-installed during installation. D2D Series: Cl. I, Div. 2, Groups B†, C, D Cl. I, Zone 2, IIB + H2† Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 Standard Materials and Finishes: • Circuit breaker enclosure body and cover – copper-free aluminum • Terminal housing – type 316L stainless steel ("S") or copper-free aluminum ("A") • Gasket – neoprene (cast aluminum enclosure); foam-in-place (stainless steel enclosure) • Operating handles – copper-free aluminum • Operating shafts and bushings, cover bolts, washers, hinges, breather/drain, retractile springs – stainless steel • Circuit breaker operators – EXD/D2D Size F: copper-free aluminum; all other types: non-metallic • Lifting bracket – electrogalvanized cold rolled steel • Chassis – silver-plated copper • Breather cap – Delrin® non-metallic material • Neutral and ground bar – tin-plated aluminum †Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for Sizes B, C, and D separately. ‡NEMA 4X rating is available when ordered with suffix S752 or S753. Delrin® is a registered trademark of DuPont. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 641 1A PowerPlus™ Panelboards 1A Power EXD Series (Div. 1 & 2) D2D Series (Div. 2) D2D Series: EXD Series: Cl. I, Div. 2, Groups B†, C, D Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Zone 2, IIB + H2† Cl. I, Zone 1 & 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. II, Div. 2, Groups F, G Cl. III Cl. III NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 † Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for sizes B, C and D separately. ‡ NEMA 4X rating is available when ordered with suffix S752 or S753. 642 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business PowerPlus™ Panelboards Power EXD Series (Div. 1 & 2) D2D Series (Div. 2) EXD Series: Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Zone 1 & 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 D2D Series: Cl. I, Div. 2, Groups B†, C, D Cl. I, Zone 2, IIB + H2† Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 1A 1A † Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for sizes B, C and D separately. ‡ NEMA 4X rating is available when ordered with suffix S752 or S753. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 643 1A PowerPlus™ Panelboards Power EXD Series (Div. 1 & 2) D2D Series (Div. 2) EXD Series: Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Zone 1 & 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 Electrical Ratings: Options: Branch Breakers Trip Ratings: To add the following features to the panelboard, add a dash and then the suffix to the Cat. No. When multiple suffixes are needed, add them to the Cat. No. in alpha-numeric order. Panel Size B C D F Voltage 480Y/277 480Δ 480Y/277 480Δ 480Y/277 480Δ 480Y/277, 480Δ, or 600Δ†† Phase / Wire 3P 4W 3P 3W 3P 4W 3P 3W 3P 4W 3P 3W 3P 3W or 3P 4W Main Breaker Amperage Up to 100 Up to 100 Up to 100 Up to 100 Up to 225 Up to 225 Up to 225 Branch Breaker G-frame G-frame G-frame G-frame G-frame G-frame F-frame Panel Sizes B, C, and D (G-Frame CutlerHammer™): 1A D2D Series: Cl. I, Div. 2, Groups B†, C, D Cl. I, Zone 2, IIB + H2† Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 • 1-, 2-, and 3-pole: GHB 480/277Y (standard offering) • 2- and 3-pole: GDB 480Δ (requires suffix -GDB) • 1-, 2-, and 3-pole GBH 600Y/347 (requires suffix -GBH; contact factory) • 15, 20, 25, 30, 35, 40, 45, 50 amp (available in all breaker spaces in panel), 60, 70, 80, 90, 100 amp (only 3 breaker spaces available)‡‡ • Ambient compensated breakers are optional to +50°C (suffix V) Panel Size F (F-frame breaker: EHD CutlerHammer™ standard): • 15, 20, 25, 30, 35, 40, 45, 50, 60, 70 amp (available in all breaker spaces in panel), 80, 90, 100 amp (only 3 breaker spaces available) • Breaker types available††† - FDB: 2-, and 3-pole 600V - FD: 1-, 2- (277V), and 3-pole (600V) - HFD: 1-, 2- (277V), and 3-pole (600V) - EHD: 1-, 2- (277V), and 3-pole (480V) Description Suffix Space heater ............................................................................ R44 Square head plugs on all conduit openings• .......................... SP Epoxy powder coat finish, external ......................................... S752 Epoxy powder coat finish, internal and external ..................... S753 Recess head plugs on all conduit openings• .......................... RP Stainless steel breaker operator cover (ice shield) .................. HG Group B kit factory installed .................................................... GB GFI breakers✪ ......................................................................... G EPD breakers✪ ........................................................................ E HID breakers✪ ......................................................................... H Ambient compensated breakers (50ºC) .................................. V GDB 480Δ 3P 3W system■ .................................................... GDB FDB 600V breakers* ................................................................ FDB600 FD 600V breakers* ................................................................... FD600 HFD 600V breakers* ................................................................ HFD600 Lamacoid Nameplate ............................................................... LID A standard panelboard has conduit openings for power and branch circuits on top. To order a panelboard with main power feed from the bottom of breaker housing, and branch entries on top (alternate) ..................................................................................... -A** To order an inverted panelboard with all conduit openings for power and branch circuits on the bottom (inverted) ................... To order an inverted panelboard with main power feed on top and bottom (alternate inverted) ............................................. -A-I** Main Breaker Trip Ratings: • 2- and 3-pole (contact factory for single phase sizes B, C, D) • Size B, C: 15 to 100 amps • Size D, F: 15 to 225 amps Main Lugs: • Size B, C, and F: 225 amps • Size D: not available; main breaker only Ampere Interrupting Capacity: • All size panels are certified to 10kAIC • Breaker AIC Ratings: - GHB Breaker: 14kAIC at 480Y/277 - EHD Breaker: 14kAIC at 480V Breaker types optional with Sizes B, C, and D panel only: - GDB Breaker: 14kAIC at 480V Breaker types optional with Size F panel only: - FDB Breaker: 14kAIC at 480V and 600V - FD Breaker: 18kAIC at 600V and 35kAIC at 480V & 277V - HFD Breaker: 25kAIC at 600V and 65kAIC at 480V & 277V †Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix –GB. For field installable kit, order EXD-GB-KIT for Sizes B, C, and D separately. ‡NEMA 4X rating is available when ordered with suffix S752 or S753. ††For 480Δ 3P 3W system or for 600VAC, a suffix is required. Note: for single-pole 480Δ, GHB breakers will be furnished for Sizes B, C, and D. ‡‡Two-pole GDB breakers are only available up to 50 amps. †††F-frame breakers are only available in Size F panel with up to a maximum of 30 circuit spaces. ✪Please contact factory. Single pole 480V EPD available. For all others, please contact factory. Two breaker positions for single pole EPD: odds start at position 1; evens start at position 4. ■Available in D2D and EXD Sizes B, C, and D only. *Available with D2D and EXD Size F panels only. **D2D/EXD Sizes C and D are only available with up to 36 circuits. •Not available on stainless terminal housings. 644 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 -I Copyright© 2013 Eaton’s Crouse-Hinds Business PowerPlus™ Panelboards Power EXD Series (Div. 1 & 2) D2D Series (Div. 2) EXD Series: Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Zone 1 & 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 D2D Series: Cl. I, Div. 2, Groups B†, C, D Cl. I, Zone 2, IIB + H2† Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 Accessories: Terminal Housing Mounting Plate Kit: Gland Plates To adapt depth of terminal housing to same depth as breaker enclosure *** Panel Types / Sizes Part Number D2D/EXD Sizes B, C, D EXDA-MTG-KIT D2D Sizes B, C, D D2DS-MTG-KIT Field installable gland plates with factory-provided aluminum Myers™ Hubs for the D2D stainless steel terminal housing (one 3inch hub and 12 branch entry hubs - size dependent upon suffix, each kit includes 3 gland plates, 1 for the top or bottom and 1 for each side): Part Number 3 /4" branch entry hub D2D HUB2 KIT 1" branch entry hub D2D HUB3 KIT 1 1/2" branch entry hub D2D HUB5 KIT Replacement gland plate (no hubs) D2D HUB0 KIT 1A Terminal Housing Aluminum Stainless Circuit Breaker Operator Assemblies: Operator Assemblies D2D/EXD All breakers panel Sizes B, C, D D2D/EXD All breakers panel Sizes F Part Number EXD HDL123 EXD K1 Replacement Cover Plugs: For unused circuit breaker positions (qty. 5): Plug Kits D2D/EXD Sizes B, C, D D2D/EXD Size F Part Number EXD OP PLG EXD K2 1A Kit for Group B Standard panels less -GB suffix are applicable for Group B, but it is required to install brackets on breakers. Part Number To order brackets factory installed add suffix -GB For field installable kit (Sizes B, C, D) EXD GB KIT D2D/EXD Stainless Steel Breaker Operator Cover To protect operators from ice build-up for all D2D/EXD PowerPlus panels: D2D/EXD PowerPlus panels Part Number Contact Factory Space Heater Kit D2D/EXD PowerPlus panels EXD R44 KIT †Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for Sizes B, C, and D separately. *** The weight of the panel is sufficiently supported by mounting of breaker enclosure. ‡NEMA 4X rating is available when ordered with suffix S752 or S753. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 645 1A PowerPlus™ Panelboards Power EXD Series (Div. 1 & 2) D2D Series (Div. 2) D2D Series: EXD Series: Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Div. 2, Groups B†, C, D Cl. I, Zone 1 & 2, IIB + H2† Cl. I, Zone 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. II, Div. 2, Groups F, G Cl. III Cl. III NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 Table A – Panel Capacity Maximum Number of Breaker Spaces: Max. No. of Branch Circuit Breaker Spaces Panel With Main With Main Breaker Size Lug Only 2-pole* 3-pole Available Main Breaker Ampacity Available With GFI, EPD Branch Protection*** B C D F Up Up Up Up No No No No 24 42 N/A 30 22 40 42 30 21 39 42 30 to to to to 100■ 100■ 225✪ 225✪ Table B – To Size Panels with GFI or EPD Branch Breakers Maximum Number of GFI or EPD Breakers Panel Size with Main Lug SingleTwoor Main Breaker Pole Pole B 1A C D 12 (10 with 3-pole MCB, 11 with 2-pole MCB) 21 14 EPLDN only - can go up to 42 GFI or EPD circuits. EPLDN will accommodate up to 225 amp main breaker. 21 Each factory-sealed panel is equipped with 42 load wires for GFI/EPD breakers and any combination with standard branch breakers. Determine the total number of load wires required to complete your panel. You may not exceed 42 load wires. Load Wires Required Single-pole breaker 1 Single-pole GFI (or EPD) breaker 2 Two-pole breaker 2 Two-pole GFI (or EPD) breaker 3 Three-pole breaker 3 Maximum Total: 42 load wires (factory sealed) Maximum Total: 82 load wires EPLDN Panels (non-factory sealed) † Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for Sizes B, C and D separately. ‡ NEMA 4X rating is available when ordered with suffix S752 or S753. * Contact factory for single phase size B, C, or D. ✪ Main breakers are mounted external to chassis. ■ Main breakers are chassis mounted and back-fed. ***GFI, EPD for D2D/EXD are not standard options. If required, please contact factory. Single pole 480V EPD available. For all others, please contact factory. Two breaker positions for single pole EPD: odds start at position 1; evens start at position 4. 646 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business PowerPlus™ Panelboards Power EXD Series (Div. 1 & 2) D2D Series (Div. 2) EXD Series: Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Zone 1 & 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 1A D2D Series: Cl. I, Div. 2, Groups B†, C, D Cl. I, Zone 2, IIB + H2† Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 Power Panelboard Catalog Number Example Example: Class I, Division 2 / Zone 2, Group B panel with: • 480ΔVAC power panelboard with 3-phase, 3-wire • (42) single-pole 20 amp branch breakers • 225 amp 3-pole main circuit breaker 1A † Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for sizes B, C and D separately. ‡ NEMA 4X rating is available when ordered with suffix S752 or S753. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 647 1A EXD Series: Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Zone 1 & 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 PowerPlus™ Panelboards Power EXD Series (Div. 1 & 2) D2D Series (Div. 2) D2D Series: Cl. I, Div. 2, Groups B†, C, D Cl. I, Zone 2, IIB + H2† Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 Dimensions Size B Panel* (With Stainless Steel Terminal Housing) 20.12 [511.2] 1.83 [46.5] 11.16 [283.4] 4.00 [101.5] 11.37 [288.9] APPROXIMATE 48.36 [1228.3] 3 1/2" NPT ALTERNATE FEED OPTION (SUFFIX 'A') ONLY 1A 17.25 [438.2] 6.17 [156.7] 21.88 [555.6] Size C and D Panel* (With Cast Aluminum Terminal Housing) 6.50 4.66 [165.1] 2.81 [118.4] 71.4 1-1/2" NPT 12 PLACES 6.50 [165.1] 4.66 [118.4] 2.81 71.4 3.51 [89.2] TYP. 5.10 [129.5] TYP. .92 [23.4] 3 1/2" NPT 1.31 [33.3] 5.50 [139.7] .50 [12.7] 13.49 [342.7] APPROXIMATE 62.15 [1578.5] 28.25 [717.6] 6.82 [173.3] 21.88 [555.6] † Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for sizes B, C and D separately. ‡ NEMA 4X rating is available when ordered with suffix S752 or S753. *Stainless steel and cast aluminum terminal housing for sizes B, C, and D panels have same dimensions. Note: Value series non-factory-sealed EXD*N panel dimensions are the breaker housing only and use standard entries shown on cast terminal housing. 648 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business PowerPlus™ Panelboards Power EXD Series (Div. 1 & 2) D2D Series (Div. 2) EXD Series: Cl. I, Div. 1 & 2, Groups B†, C, D Cl. I, Zone 1 & 2, IIB + H2† Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 D2D Series: Cl. I, Div. 2, Groups B†, C, D Cl. I, Zone 2, IIB + H2† Cl. II, Div. 2, Groups F, G Cl. III NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12 1A Size F Panel 1A † Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for sizes B, C and D separately. ‡ NEMA 4X rating is available when ordered with suffix S752 or S753. *Stainless steel and cast aluminum terminal housing for sizes B, C, and D panels have same dimensions. Note: Value series non-factory-sealed EXD*N panel dimensions are the breaker housing only and use standard entries shown on cast terminal housing. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 649 1A Cl. I, Zone 1, Aex de IIC T4 Ex de IIC T4 Cl. I, Div. 2, Groups A, B, C, D Cl. II, Div. 1, Groups E, F, G, Extb IIIC T100°C Db SynergEX Panelboards Power, lighting, and heat tracing panels for Class I, Division 2 applications Type 4X, IP66 SynergEX Panelboards offer superior solutions utilizing individually encapsulated circuit breakers to provide maximum safety in the most extreme environments. The finger safe design provides ultimate flexibility and speed during installation, normal operations and maintenance activities in the field. This advanced design is approved for all hazardous gases, which allows for operation in multiple locations and hazardous situations. Applications: SynergEX Panelboards provide overcurrent and short circuit protection for low voltage power, lighting, and heat tracing applications in indoor and outdoor hazardous areas, such as: • Refineries • Chemical and petrochemical plants • Mining • Corrosive process facilities • Food processing facilities • Indoor and outdoor industrial applications 1A Features: • • • • • • • • • Lightweight design for reduced labor and equipment installation Dead-front design allows for operating breakers without hot permit Finger safe design eliminates safety risk for personnel Patented friction welded encapsulated molded-case circuit breakers Robust design providing operations in all gas groups and extreme hot/cold environments Front viewing window for easy visual indication of breaker status Quick snap encapsulated circuit breakers (no bolts or screws) Removable gland plates for easy addition of entries Gangable for main breaker housing Certifications and Compliances: NEC/CEC: • Class I, Zone 1, Aex de IIC T4 • Ex de IIC T4 • Class I, Division 2, Groups A, B, C, D • Class II, Division 1, Groups E, F, G, Extb IIIC T100°C Db • Type 4X, IP66 Electrical Ratings: SynergEX Panelboard: • Max. 225A / Phase (3 phase max.) • Max. 480VAC • Max. 225A main breaker (external enclosure) • 10kA short circuit current Encapsulated Circuit Breakers: • 480/277VAC - 1-, 2- and 3-pole - 10, 15, 20, 25, 30, 35, 40 amps - Auxiliary and signal contact • 240/120VAC - 1-, 2- and 3-pole - 10, 15, 20, 25, 30, 35, 40 amps - 1-pole GFI and EPD - Auxiliary and signal contact Standard Materials: • Enclosure – 316L stainless steel or painted steel • Observation window – laminated safety glass • External parts (hinges, screws, washers, 1/4 turn locks, gland plates) – 316L stainless steel • Internal parts (screws, washers, back plate, fasteners) – 304 stainless steel • Gasket – silicone • Dead-front panel – flame rated fiberboard (V-1) • Bus bars – nickel-plated copper • Filler plates – flame rated nylon (V-0) • Bonding/grounding assembly – brass • Encapsulated circuit breakers – flame rated nylon (V-2) Options: Description Breather and Drain Main Breaker (100A, 150A, 225A) Heater (-40°C) Bottom Feed Inverted Panelboard Gland Plates (see locations below) Top View 6 5 3 8 Left View Right View 4 7 1 2 Bottom View 650 www.crouse-hinds.com US: 1-866-764-5454 Suffix BD See Catalog Numbering System HTR I GP1-GP8 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business SynergEX Panelboards Cl. I, Zone 1, Aex de IIC T4 Ex de IIC T4 Cl. I, Div. 2, Groups A, B, C, D Cl. II, Div. 1, Groups E, F, G, Extb IIIC T100°C Db Power, lighting, and heat tracing panels for Class I, Division 2 applications Type 4X, IP66 1A A D C 1A B E A Extreme temperature durability - This panelboard is designed to withstand temperatures ranging from -40°C to +55°C, offering operational durability in the most extreme environments. B Efficient breaker operation - Dead front design allows for breakers to be easily and quickly reset. C Certified for all hazardous gases - The individually encapsulated breakers are certified for all hazardous gases (ABCD, IIC), allowing an end-user to install the product in a variety of hazardous locations. D Finger safe configuration - Enhanced finger safe design prevents contact with live parts, ensuring personnel safety. E Quick snap, screwless breaker replacement - Our circuit breakers are individually encapsulated without any bolts or screws, greatly reducing installation time and cost. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 651 1A Cl. I, Zone 1, Aex de IIC T4 Ex de IIC T4 Cl. I, Div. 2, Groups A, B, C, D Cl. II, Div. 1, Groups E, F, G, Extb IIIC T100°C Db SynergEX Panelboards Power, lighting, and heat tracing panels for Class I, Division 2 applications Type 4X, IP66 Catalog Numbering System: SERIES SIZE MATERIAL PANEL PHASE PANEL VOLTAGE RATING BREAKER SPACES ASTERISK QUANTITY OF ALIKE BRANCH BREAKERS BRANCH BREAKER POLE RATING BRANCH BREAKER AMPERE RATING DASH MAIN BREAKER DASH OPTIONS GLAND PLATES SPB A S 1 1 12 * 12 1 10 - 3M100 - HTR GP1GP2GP3 Series SPB Enclosure Size A = 12 CCT B = 24 CCT C = 42 CCT D = 60 CCT Enclosure Material Type S = 316L Stainless Steel (Type 4X) P = 304 Painted Steel (Type 4X) 1A Panel Phase 1 = Single Phase 3 = Three Phase Panel Voltage Rating 1 = 120/240V (1 Phase, 3 Wire) 2 = 208/120V (3 Phase, 4 Wire) 4 = 480/277V (3 Phase, 4 Wire) Breaker Spaces 1P Breaker = 1 Space TOTAL NUMBER OF BREAKER SPACES UTILIZED 2P Breaker = 2 Spaces ROUND UP TO AN EVEN NUMBER 3P Breaker = 3 Spaces Insert Asterisk (*) Before Each Branch Breaker Series Quantity of Alike Branch Breakers Branch Breaker Pole Rating 1 = 1P Breaker 1AX = 1P Breaker + Auxiliary 1SC = 1P Breaker + Signal Contact 2 = 2P Breaker 2AX = 2P Breaker + Auxiliary 2SC = 2P Breaker + Signal Contact 3 = 3P Breaker 3AX = 3P Breaker + Auxiliary 3SC = 3P Breaker + Signal Contact 1G = 1P GFI 1E = 1P EPD Branch Breaker Ampere Rating Example: 20 = 20A NUMERICAL VALUE REPRESENTS AMPERE RATING Dash Indicates Main Breaker to Follow Main Breaker 2- or 3-pole, 15 to 225A (Example: 3M100 - 3-pole main breaker, 100A) Note: Breakers above 40A to be housed in separate enclosure Dash Indicates Options to Follow Option Suffixes (see page 4 for available options) Gland Plates 652 Gland plates at locations 1, 2 and 3 are standard www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business SynergEX Panelboards Cl. I, Zone 1, Aex de IIC T4 Ex de IIC T4 Cl. I, Div. 2, Groups A, B, C, D Cl. II, Div. 1, Groups E, F, G, Extb IIIC T100°C Db Power, lighting, and heat tracing panels for Class I, Division 2 applications 1A Type 4X, IP66 Dimensions: 12 Circuits 11.81” (300mm) 11.81” (300mm) 24 Circuits 37.40” (950mm) 30.51” (775mm) 1A 43.31” (1100mm) 37.40” (950mm) 60 Circuits 11.81” (300mm) 11.81” (300mm) 42 Circuits 37.40” (950mm) www.crouse-hinds.com US: 1-866-764-5454 50.39” (1280mm) 62.99” (1600mm) 74.80” (1900mm) CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 653 1A Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1, Group IIC Cl. II, Div. 1, Groups E, F, G D2Z Panelboards Zone 1, Division 2 AEx de II C T4, T6 Ex de IIC T4, T6 NEMA 4X, IP65 Non-metallic or Stainless Steel Applications: D2Z panelboards are designed specifically for use in: • Class I, Zone 1, Division 2, Groups A, B, C, D hazardous area locations. • In damp, wet or corrosive locations. • Indoors or outdoors in Zone 1, Division 2 areas of petroleum refineries, chemical and petrochemical plants, and other process industry facilities. 1A Features: • cCSAus, PTB* certified for Class I, Zone 1, Division 2 hazardous areas. • Fiberglass-reinforced polyester enclosures: Non-metallic, corrosion-free Increased safety Ex-e protection Impact resistant NEMA 4X, IP65 Enclosure meets UL 94-VO UV listed • 316L stainless steel enclosures (suffix S860): Corrosion resistant Industrial grade thickness NEMA 4X, IP65 • Unique design allows for panels with more than 42 circuits. • Main disconnect switches 40, 80, 125, 180A. • Optional flameproof Ex-d fusing of main disconnect. • Flameproof Ex-d encapsulated UL 489 branch circuit breakers: Thermal-magnetic protection up to 40A with 240 VAC circuit breakers. Thermal-magnetic protection up to 25A with 480 VAC circuit breakers. Auxiliary contacts (mechanical or electrical).** Lockout on components. Prewired to Increase Safety terminal blocks. GFI branch breakers (EPDs).** • Clear, NEMA 4X / IP65 window, hinged for actuation or breakers. • Double lockout on windows and breakers. • Brass plates for hub or cable gland entries. • Enclosures are to be vertically mounted on switchrack frames or walls. • Completely pre-wired ready for connection to terminal blocks. D2Z with fiberglass-reinforced polyester enclosure Certifications and Compliances*: Certifications Degree of Protection cCSAus NEMA 4X IP65 to IEC 60529 ISO 4892 Glass-reinforced polyester -55°C to 40°C*** 480 VAC Max. 180A UV Resistance Enclosure Material Temperature Ratings Rated Voltage Rated Current • NEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 1, Group IIC • CEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 1, Group IIC Class II, Division 1, Groups E, F, G • UL Standards: UL60079-0 UL60079-1 UL60079-7 UL60079-18 • CSA Standards: C22.2 E60079-0-02 C22.2 E60079-1-02 C22.2 E60079-7-2003 C22.2 E60079-18-95 654 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 D2Z with 316L stainless steel enclosure (suffix S860) Options: The following special options are available from the factory by adding the suffix to the Cat. #: Description Suffix D2Z Series panelboards are now available with 316L stainless steel enclosures. This material is ideal for wash down and corrosive areas requiring product endurance in adverse locations. S860 *Available with ATEX certification, please consult factory. **Available with only UL 1077 supplemental protectors. ***For ambients -20ºC or less, optional heater is required. Copyright© 2013 Eaton’s Crouse-Hinds Business D2Z Panelboards Zone 1, Division 2 AEx de II C T4, T6 Ex de IIC T4, T6 NEMA 4X, IP65 Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1, Group IIC Cl. II, Div. 1, Groups E, F, G 1A Non-metallic or Stainless Steel Technical Data Branch Circuit Breakers 1-pole, 2-pole, 3-pole, 4-pole; with EPD protection 1-pole + Neutral, 2-pole; 2, 6, 10, 16, 20, 25, 32 and 40 Amps Explosion Protection Certifications Rated Operating Voltage Rated Current Rated Switching Capacity Circuit Breaker Characteristics Tripping Characteristics Tripping Current for EPDs Circuit Breaker Enclosure Materials Optional Auxiliary/Signal Contacts** Rated Voltage Rated Current 250 VAC 5A Main Disconnect Switch 1A • Large windows permit easy viewing and quick access to breakers without opening the enclosures. • Lockouts standard for both windows and breakers • Up to 6 single-pole breakers can be installed under one window. • NEMA 4X, IP65 protection. • Window locks with 5/16" (8mm) Allen Key. Ex de IIC AEx de IIC Class I, Zone 1, Div. 2, Groups A, B, C, D Class II, Div. 1, Groups E, F, G cCSAus Up to max. 480 VAC Up to 40A 10k AlC UL489 Circuit Breakers "Z" or "K"* 30mA (up to 300mA on request) Fiberglass-reinforced epoxy 40, 80, 125, 180A, 4-pole Explosion Protection Ex de IIC T6 AEx de IIC T6 Class I, Zone 1, Div. 2, Groups A, B, C, D Class II, Div. 1, Groups E, F, G Rated Operating Voltage Up to 690 VAC Motor Switching Capacity AC3*** Type 40A 80A 125A 180A 230V 40A 80A 125A 180A 400V 40A 80A 125A 180A 500V 40A 80A 125A 150A 690V 32A 63A 110A 125A Main Switch • 40A main switch, 4-pole, optional fusing in enclosure with window(s). • 80, 125 and 180A main switch, 4-pole, optional fusing in enclosure. ***See IEC 60947-3. * "Z" Branch breakers are used for all general applications such as lighting and heat tracing. Type "K" breakers are used for MOVs and portable power. Contact factory for other application. ** Aux contacts indicate mechanical or electrical tripping Signal contacts indicate only electrical tripping and are used primarily on heat-tracing circuits. Branch breakers with signal contacts require next larger breaker enclosure. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 655 D2Z Panelboards Zone 1, Division 2 1A Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1, Group IIC Cl. II, Div. 1, Groups E, F, G AEx de IIC T4, T6 Ex de IIC T4, T6 NEMA 4X, IP65 Non-metallic or Stainless Steel Main Fuse, 3-pole Explosion Protection Ex de IIC AEx de IIC Class I, Zone 1, Div. 2, Groups A, B, C, D Rated Operating Voltage Up to max. 500 VAC Rated Current Current Temperature Class in Board 25A T6 35A T5 50A T4 63A T4 80A T4 100A T4 125A T4 Recommended manufacturer: Eaton's Bussmann type NH00G fuses for general use or N00M for motor applications. Specify Amperage (Fuses not provided) Main Fuse, type NH Standard Entries Metric Entries (remove hubs) (1) 2" + (3) 1" (9) 3/4" (1) M63 + (3) M32 (9) M25 1A Main supply Branches Brass gland plate with Zone 1 Myers adapter hubs: (STM series) • Universal Wiring – Zone 1 Myers™ adapter hubs for conduit or Terminator™ cable glands. • Stainless Steel Hubs – available upon request. 656 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business D2Z Panelboards Zone 1, Division 2 Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1, Group IIC Cl. II, Div. 1, Groups E, F, G AEx de II C T4, T6 Ex de IIC T4, T6 NEMA 4X, IP65 1A Non-metallic or Stainless Steel SpecOne™ D2Z Panelboard Construction Layout Example of D2Z distribution panel with built-in components under the window. (available mounting width = 213mm) 1A D2Z panel with 3 mounting spaces 1 2 3 4 5 6 7 8 9 10 Mounting Space – 190mm Mounting Space – 190mm Mounting Space – 190mm (2) 4 pole breakers – width 106mm each (available mounting width – 213mm) (3) 3 pole breakers – width 70mm each (available mounting width – 213mm) (4) 2 pole breakers – width 53mm each (available mounting width – 213mm) (6) 1 pole breakers – width 35mm each (available mounting width – 213mm) 40A main switch, 4-pole. 1 mounting space required Main fuse. 1 mounting space required in place of 1 window Window www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 657 1A D2Z Panelboards Zone 1, Division 2 AEx de II C T4, T6 Ex de IIC T4, T6 NEMA 4X, IP65 Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1, Group IIC Cl. II, Div. 1, Groups E, F, G Non-metallic or Stainless Steel Ordering Procedure Step 1: Window Determine the number of windows required from the following chart based on the number of branch breakers. Multiply breaker space by number of breakers. Round the sum total to the next highest whole number to determine required windows. i.e. For (8) 1-pole and (2) 2-pole breakers: (8 x 0.16) + (2 x 0.25) = 1.78 = 2 windows required. Max. No. Per Window Branch Circuit Breakers (max 40A) Space Required For Each Breaker 1-pole .16 4 2-pole or 1-pole with EPD or 1-pole with signal contact .25 3 3-pole or 1-pole + Neutral with signal contact or 2-pole with signal contact .33 2 4-pole or 2-pole with EPD or 3-pole with signal contact .50 1A 6 Step 2: Disconnect Switch If a disconnect switch is required, select suffix from table. Main Switch Disconnect 40 80 125 180 3-phase –3S* 40 –3S* 80 –3S* 125 –3S 180 Single Phase –2S* 40 –2S* 80 –2S* 125 — *Add F if fuses required. Fuses supplied by others. See page 656 658 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business D2Z Panelboards Zone 1, Division 2 1A AEx de II C T4, T6 Ex de IIC T4, T6 NEMA 4X, IP65 Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1, Group IIC Cl. II, Div. 1, Groups E, F, G Non-metallic or Stainless Steel Step 3: Panel Size Determine Panel Size Based on Windows Required Number of Windows Required Type Required Disconnect 1, 2 3 4–6 7–9 A mini panel B panel C panel D panel 40A disconnect – Integral Optional – Adjacent Optional – Adjacent Optional – Adjacent Type A Mini Panels with Main Switch 40A 3-Phase 40A Fused 3-Phase D2Z D2Z D2Z D2Z D2Z A306 - 3SF40* A306 A308 A310 A312 - 3S40* 3S40* 3S40* 3S40* Single Phase D2Z D2Z D2Z D2Z D2Z A106 - 2SF40* A106 A108 A110 A112 - 2S40* 2S40* 2S40* 2S40* 6 8 10 12 Quantity of Single Circuits 6 8 10 12 1A Single Phase Quantity of Single Circuits *See page 661 to complete catalog number. Panels Type B, C, and D www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 659 1A Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1, Group IIC Cl. II, Div. 1, Groups E, F, G D2Z Panelboards Zone 1, Division 2 AEx de II C T4, T6 Ex de IIC T4, T6 NEMA 4X, IP65 Non-metallic or Stainless Steel Step 4: Conduit/Cable Entries Determine if additional entries are required on sides B and C. All panels are supplied with bottom entries (Side A), 1 main supply and remainder as branches. Example: Size D panels with disconnect switch have 1 main supply and 3 branch plates as standard. Main Entries Entries Location Main Supply (1) 2" + (3) 1" A (Standard) Branches (9) 3/4" (B panel) (18) 3/4" (C panel) (27) 3/4" (D panel) A (Standard) A (Standard) A (Standard) Branches (9) 3/4" (9) 3/4" B (Optional) left side C (Optional) left side 1A Type Terminal Wiring Supply Circuits Amperage mm2 AWG Branch Circuits Amperage mm2 AWG 40 80 125 180 16 35 70 95 6-18 2-6 8-2/0 6-3/0 10 15 20 40 4 4 10 16 12-22 12-22 6-14 6-18 660 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1, Group IIC Cl. II, Div. 1, Groups E, F, G D2Z Panelboards Zone 1, Division 2 AEx de II C T4, T6 Ex de IIC T4, T6 NEMA 4X, IP65 1A Non-metallic or Stainless Steel How to Build a Catalog Number‡ 1A www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 661 D2Z Panelboards Zone 1, Division 2 1A Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1, Group IIC Cl. II, Div. 1, Groups E, F, G AEx de II C T4, T6 Ex de IIC T4, T6 NEMA 4X, IP65 Non-metallic or Stainless Steel Please state rated current on order: 2, 6, 10, 16, 20, 25, 32 or 40A.* Spare Component Information Lighting Circuits Order Code 10k AIC, max. 480 VAC 1-pole 6/window SIA 001 2-pole 4/window SIA 002 Optional: Auxiliary contact – SAH 001 Signal contact – SAS 001 (in the case of branch breakers with signal contacts, the next largest component size is used) 3-pole 3/window SIA 003 4-pole 2/window SIA 004 Heat-Tracing Order Code EPD with 10k AIC, 30mA leakage, max. 480 VAC Example: SIA 001-20 – SAH001 Single Pole, 20A with auxiliary contacts Please state rated current on order: 6, 10, 16, 20, 25, 32 or 40A. 1A Optional: With auxiliary contact – FSH 001 With signal contact in Size 4 component – FSS001 Example: FSS 004 - 30 – FSS001 EPD, 30A, 30mA with signal contact 1-pole + N 4/window FSS 002 2-pole 2/window FSS 004 *25 ampere max. for 480VAC breakers. Dimensions Used only for fuses on 80, 125 or 180A disconnect switches Used only for fuses on 80, 125 or 180A disconnect switches without fuses. Used for – 40A switch with fuses and 1 window or – 40A switch and 2 windows, or – 3 windows of branch breakers. Dimensions in mm X = mounting dimensions 662 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business D2PB Division 2 Circuit Breaker Panelboards Factory Sealed, Single & Two-Pole Circuit Breakers Applications: Standard Materials: D2PB panelboards are designed specifically for use: • In Class I, Division 2, Groups C, D hazardous areas where flammable vapors or gases may be present due to accident or abnormal locations • In damp, wet or corrosive locations • Indoors or outdoors in Division 2 areas of petroleum refineries, chemical and petrochemical plants, and other process industry facilities For general application, circuit breaker and wiring system information, see pages 626–629. • Bodies, covers and hinged doors – copper-free aluminum • Breaker operating handles – type 6 / 6 nylon • Interior parts – sheet steel Features: Standard Finishes: • Copper-free aluminum – natural • Type 6 / 6 nylon – natural (black) • Sheet steel – electrogalvanized with chromate finish Options: Description: Suffix: • Panelboard provided with operating handle lockouts for lockout in ON or OFF positions. Stainless steel lockout frame integral to panel faceplate. D2PB Size 1..................................... L12 D2PB Size 2..................................... L24 • Branch conduit entries furnished with Eaton's Crouse-Hinds type PLG plugs.......................................... S822 • Square head plugs in all openings.... S872 • Branch circuit conduit openings located at bottom instead of at top.. INV • Drilled and tapped conduit openings other than standard – available on special order – specify.. I • Breather and drain............................ DV • Circuit breaker operating handle lockout - order D2PB02 • Assortment of single-pole and two-pole circuit breakers and trip ratings – see listings. Wiring system other than those listed – Specify See page 628 Dimensions 1A • Enclosures are of external flange design, which makes the interior completely accessible when the cover is removed • Provided with concealed mounting, which is made possible by having four clearance holes for lag screws or mounting bolts in the back of the enclosure, one in each corner • The interior sub-assembly, consisting of a mounting plate, main terminal blocks, and circuit breakers, is removable as a complete unit • Ample gutter space is provided for ease of field wiring • Circuit breakers are contained in compact, individual factory sealed enclosures suitable for Class I, Division 2, Groups C, D hazardous areas. The individual enclosures are easily removed and replaced, therefore changing or adding individual circuit breakers will not present a problem • The main cover, which is gasketed to exclude dirt and moisture, is attached to the body with hex head bolts and is removed only when installing the panelboard or making wiring changes. In the center of the main cover is a gasketed hinged door, which provides access only to the circuit breaker operating handles, and is held closed by two quick release catches. The door can be locked by as many as 3 padlocks to prevent unauthorized operation • Tapped conduit openings are provided for main conduit and branch circuits, as shown in the dimensional information. Standard openings can be reduced or plugged to meet most installation requirements • Circuit breakers are arranged in two vertical rows and have the circuit numbers marked on the handles. The left row is numbered 1, 3, 5, 7, etc. and the right row 2, 4, 6, 8, etc. Identifying information may be typed on the circuit directory card attached to the inside of the hinged door 1A Wet Locations Cl. I, Div. 2, Groups C, D NEMA 3, 7CD (Div. 2), 12 Dust-tight Raintight Size Ranges: Panel Size Max. No. of Breakers Single-Pole Two-Pole 1 2 12 24 6 12 Electrical Rating Ranges: • • • • Circuit breakers Single-pole – 120/240VAC max. Two-pole – 120/240VAC max. Trip ratings – 15, 20 and 30 amp In Inches: Certifications and Compliances: • NEC: Class I, Division 2, Groups C, D • NEMA: 3, 7CD (Division 2), 12 • UL Standard: 67, 877 Dimensions are approximate, not for construction purposes. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 663 1A D2PB Division 2 Circuit Breaker Panelboards Cl. I, Div. 2, Groups C, D NEMA 3, 7CD (Div. 2), 12 Dust-tight Raintight Factory Sealed, Single & Two-Pole Circuit Breakers Wet Locations D2CB12-20 Replacement Circuit Breaker Assemblies D2PB with Main Breaker Option Where D2PB (and N2PB) panelboards have been ordered with less than the maximum number of circuit breakers, breakers can easily be added in the field. Circuit breaker assemblies for field addition or replacement are listed below; they consist of the breaker itself in its factory sealed Class I, Division 2, Groups C, D enclosure, and necessary mounting hardware. These assemblies are not suitable for use as individually mounted units. Ordering Information: 1A Panelboards are available with single-pole and two-pole, 15, 20, or 30 ampere circuit breakers. To order a panelboard with all breakers of the same rating, add the desired rating as a suffix to the Cat. No. For example, the 12 circuit D2PB1512 panelboard with all the circuit breakers rated at 20 amperes would be ordered as D2PB1512-20. Panelboards shown below can also be furnished with an assortment of single-pole and twopole breakers and breaker ampere ratings. To order, the quantities of breakers and ampere ratings are added as a suffix to the Cat. No. The total number of poles will determine the panel size (24 poles maximum), and the wiring systems must be compatible when combining single- and two-pole circuit breakers. For example, a typical D2PB panelboard with a combination of 3 single-pole 15 ampere, 3 single-pole 20 ampere, 2 single-pole 30 ampere, 4 two-pole 20 ampere, and 4 two-pole 30 ampere circuit breakers would be ordered as D2PB2508-315-320-230-808-420-430. The total number of poles is 24 and wiring systems 5 and 8 are compatible 4 wire, 3 phase. The D2PB with a main breaker is available up to 100 amps. To order D2PB with main breaker, add the appropriate suffix. Example: D2PB1512-15 with three-pole, 100 amp main circuit breaker would be ordered as D2PB1512-15-3M100. If two-pole main is required, change the number 3 to 2. If a lower trip rating than 100 is required, the suffix will change accordingly. Max. No. of Breakers SinglePole TwoPole Panel Size Main Lug Size‡ 6 8 10 12 4 5 6 1 1/0 12 6 14 7 16 8 2 4/0 18 9 20 10 22 11 24 12 ➀Add ampere rating. See ordering information. Single-Pole Circuit Breakers Wiring System 4* Wiring System 5* Mains: 3-Wire Mains: 4-Wire, 3-Phase Branches: 2-Wire Branches: 2-Wire Solid Neutral Solid Neutral Cat. # Cat. # Circuit Breaker Assemblies Ampere Rating Single-Pole Cat. # Two-Pole Cat. # 15 20 30 D2CB11 15 D2CB11 20 D2CB11 30 D2CB12 15 D2CB12 20 D2CB12 30 Two-Pole Circuit Breakers Wiring System 3* Wiring System 8* Mains: 3-Wire Mains: 4-Wire, 3-Phase Branches: 3-Wire Branches: 3-Wire, 1-Phase Solid Neutral Solid Neutral Cat. # Cat. # D2PB1406 D2PB1408 D2PB1410 D2PB1412 ➀ ➀ ➀ ➀ D2PB1506 D2PB1508 D2PB1510 D2PB1512 ➀ ➀ ➀ ➀ D2PB1304 ➀ D2PB1305 ➀ D2PB1306 ➀ D2PB2412 D2PB2414 D2PB2416 D2PB2418 D2PB2420 D2PB2422 D2PB2424 ➀ ➀ ➀ ➀ ➀ ➀ ➀ D2PB2512 D2PB2514 D2PB2516 D2PB2518 D2PB2520 D2PB2522 D2PB2524 ➀ ➀ ➀ ➀ ➀ ➀ ➀ D2PB2306 D2PB2307 D2PB2308 D2PB2309 D2PB2310 D2PB2311 D2PB2312 D2PB1804 ➀ D2PB1805 ➀ D2PB1806 ➀ ➀ ➀ ➀ ➀ ➀ ➀ ➀ D2PB2806 D2PB2807 D2PB2808 D2PB2809 D2PB2810 D2PB2811 D2PB2812 p ➀ ➀ ➀ ➀ ➀ ➀ ➀ ‡1/0 lug, rated 125 amps. takes wire sizes #6 to 1/0; 4/0 lug, rated 225 amps. takes wires sizes 1/ 0 to 4/ 0. *For description of these standard wiring systems, see page 628. Dimensions Overall and Mounting Dimensions (In.) a b c Panel Size Without Main C.B. 1 203/4 8 16 2 113/4 231/2 281/4 Conduit Openings Spacing (In.) f g h j Size (In.) k m n✪ 73/4 113/8 3 3 11/4 11/4 11/4 11/4 11/4 11/4 Panel Size With Main C.B. 1 8 16 73/4 203/4 2 113/4 231/2 113/8 281/4 ✪Conduit opening "n" not supplied on panel size 1. 664 www.crouse-hinds.com US: 1-866-764-5454 31/2 31/16 2 115/16 115/16 5 5 115/16 115/16 115/16 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 21/2 21/2 Quantity Main Branches 2 2 8 12 2 2 8 12 D2PB, D2L, D2D Circuit Breaker Panelboard Assemblies Cl. I, Div. 2, Groups B†, C, D NEMA 3, 4‡, 7B†CD (Div. 2), 12 Wet Locations Watertight‡ with Transformer Applications: Standard Materials: D2PB, D2L, D2D circuit breaker panelboard assemblies with transformers are for use: • In Class I, Division 2, Group C, D hazardous areas where, due to accident or abnormal operations, flammable vapors or gases may be present, and which are subject to weather, dampness and corrosion • Indoors or outdoors in Division 2 areas such as petroleum refineries, chemical and petrochemical plants, and other process industry facilities • Where high voltage supply must be stepped down to the lower voltage necessary to serve lighting, heating, appliance, heat tracing, motor and similar circuits For general information on panelboard applications, circuit breakers and wiring systems, see pages 626–629. • Frames – structural aluminum • Mounting hardware – stainless steel • Transformer enclosure – sheet steel, welded • For panelboard materials, see individual listing pages • The factory assembled panelboard and transformer are on one compact frame, suitable for either wall or pole mounting. Wiring between the transformer secondary and main lugs of the panelboard is accomplished at the factory. • Easy to install and wire. The main feed is connected to the transformer primary and the branch circuits are wired to the panelboard terminal blocks. • The assembly can be installed in the load area to reduce the length of runs of low voltage branch circuits. • Panelboards used are standard D2PB, D2L, or D2D units with circuit breakers listed in this section. • Transformers are compound filled or epoxy filled to completely seal out moisture and dirt. Standard Finishes: • • • • Aluminum – natural Stainless steel – natural Sheet steel – primed and painted For panelboard finishes, see individual listing pages Options: • Material – structural steel frames • Finish – primed and painted or hot dip galvanized • For options available on the panelboards themselves, see individual listings pages 1A Features: 1A Size Ranges: Transformers Single or three-phase – 5kVA to 30kVA Panelboards Max. No. of Breakers SingleTwopole pole D2PB 24 12 D2L 42 20 D2D 30 14 Threepole 14 10 Electrical Rating Ranges: • Transformers – 480 volt primary • Transformers – 120 / 240 volt secondary • Panelboards – see individual listings Certifications and Compliances: • NEC/CEC: Class I, Division 2, Group B†, C, D • NEMA/EEMAC: 3, 4‡, 7B†CD (Division 2), 12 • UL Standard: 67, 1604 • CSA Standard: C22.2 No. 213 † D2L, D2D with GB suffix and breather and drain holes plugged. ‡ NEMA 4 hosetight with breather and drain openings plugged. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 665 1A D2PB, D2L, D2D Circuit Breaker Panelboard Assemblies with Transformer Cl. I, Div. 2, Groups B†, C, D NEMA 3, 4‡, 7B†CD (Div. 2), 12 Wet Locations Watertight‡ Typical Assembly* Ordering Check List 24 Circuit D2PB panelboard with single-phase transformer 1. Select the D2PB, D2L, D2D panelboard required, together with any applicable options or special features. See individual listing pages. Cat. No. 2. Provide the following information, necessary for selection of the correct transformer: Primary voltage Secondary voltage kVA rating Taps – number and percent Frequency (60 cycle unless otherwise specified) Single or three-phase 1A Other requirements *Dimensions are approximate, not for construction purposes. † D2L, D2D with GB suffix and breather and drain holes plugged. ‡ NEMA 4 hosetight with breather and drain openings plugged. 666 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business GUSC Circuit Breaker Load Centers with Quicklag® Circuit Breakers Cl. I, Div. 1 & 2, Groups B†, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III Explosionproof Dust-Ignitionproof Raintight Wet Locations 1A Applications: GUSC circuit breaker load centers are used in: • Areas which are hazardous due to the presence of flammable vapors, gases or highly combustible dusts, and which are subject to weather, dampness and corrosion • Indoors or outdoors at petroleum refineries, chemical and petrochemical plants and other process industry facilities where similar hazards exist For general application and circuit breaker information, see pages 626–627. Features: Certifications and Compliances: Size Ranges: Max. No. of Breakers Single-pole Two-pole 2 1 Electrical Rating Ranges: 1A • Compact rectangular enclosures with round threaded covers • External operating handles can be padlocked in either "ON" or "OFF" positions • Not furnished with internal wiring as field wiring connections are made directly to circuit breaker line and load terminals. To meet varying grounding requirements, an insulated neutral terminal block is provided and is equipped with a removable grounding jumper • Bodies have 1" vertical throughfeed hubs • Quicklag circuit breakers: single-pole, 240VAC max.; two-pole, 240VAC max. • Trip ratings: 10, 15, 20, 30 and 40 amp. Options: The following special options are available from factory by adding suffix to Cat. No.: Description Suffix • Breather and drain (Class I and Class II)................................................................... S198V • Breather and drain (Class I and Class II, Groups F, G)............................................. S454V • Assortment of single and two-pole circuit breakers and trip ratings........................ Specify • NEC: Class I, Div. 1 & 2, Groups B†, C, D Class II, Div. 1, Groups E, F, G Class II, Div. 2, Groups F, G Class III • NEMA: 3, 7BCD, 9EFG, 12 • UL Standard: 1203 Standard Materials: • Bodies – Feraloy® iron alloy • Covers and operating handles – copperfree aluminum • Operating shafts – stainless steel • Interior parts – sheet steel Standard Finishes: • Feraloy iron alloy – electrogalvanized and aluminum acrylic paint • Copper-free aluminum – natural • Stainless steel – natural • Sheet steel – electrogalvanized with chromate finish †See listings for catalog numbers which are suitable for use in Group B hazardous locations. Seals must be installed within 11/ 2" of all conduit openings. Quicklag is a registered trademark of Cutler-Hammer Inc. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 667 1A GUSC Circuit Breaker Load Centers Cl. I, Div. 1 & 2, Groups B†, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III with Quicklag® Circuit Breakers Circuit Breaker Information No. of Breakers 1 2 1 Load Center With Circuit Breaker Poles Ampere Rating Hub Size Standard Units Cat. # Group B Units Cat. # 1 10 15 20 30 40 1 1 1 1 1 GUSC3110 GUSC3110 GUSC3110 GUSC3110 GUSC3110 10 15 20 30 40 GUSC3110 GUSC3110 GUSC3110 GUSC3110 GUSC3110 10 15 20 30 40 GB GB GB GB GB 1 10 15 20 30 40 1 1 1 1 1 GUSC3210 GUSC3210 GUSC3210 GUSC3210 GUSC3210 10 15 20 30 40 GUSC3210 GUSC3210 GUSC3210 GUSC3210 GUSC3210 10 15 20 30 40 GB GB GB GB GB 2 10 15 20 30 40 1 1 1 1 1 GUSC3120 GUSC3120 GUSC3120 GUSC3120 GUSC3120 10 15 20 30 40 GUSC3120 GUSC3120 GUSC3120 GUSC3120 GUSC3120 10 15 20 30 40 GB GB GB GB GB Dimensions 1A In Inches: GUSC single gang Dimensions are approximate, not for construction purposes. †See listings for catalog numbers which are suitable for use in Group B hazardous locations. Seals must be installed within 11/ 2" of all conduit openings. Quicklag is a registered trademark of Cutler-Hammer Inc. 668 Explosionproof Dust-Ignitionproof Raintight Wet Locations www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business N2PB Circuit Breaker Panelboards Factory Sealed Single & Two-Pole Breakers 1A Watertight† Cl. I, Div. 2, Groups C, D Weatherproof Cl. II, Div. 2, Groups F, G Corrosion-Resistant Dust-tight NEMA 3, 7CD (Div. 2), 9FG (Div. 2), 12 Applications: • N2PB panelboards are for use in central control and protection of a large number of feeder or branch circuits and for housing circuit breakers in Class I, Division 2, Groups C & D hazardous areas. Features: • Enclosures are made of Krydon®, Eaton's Crouse-Hinds' high impact strength fiberglass-reinforced polyester material with excellent corrosion resistance and stability to heat • Enclosure access door provided with stainless steel thumb screws for easy access; access door may be padlocked to prevent unauthorized access • Circuit breakers are contained in compact, individual factory sealed enclosures suitable for Class I, Division 2, Groups C, D hazardous areas 1A Certifications and Compliances: • NEMA 3, 7CD (Div. 2), 9FG (Div. 2), 12 • NEC: Class I, Division 2, Groups C, D Class II, Division 2, Groups F, G Options: Description Suffix • Panelboard provided with (12) operating handle lockouts for lockout in ON or OFF positions (any circuit). Stainless steel lockout frame integral to panel faceplate. N2PB Size 14 x 26 ........................ L12 N2PB Size 24 x 26 ........................ L24 • Circuit breaker operating handle lockout - order D2PB02 • Assortment of single-pole and two-pole circuit breakers and trip ratings – see listings • Grounding plate or bushing – see page 677 • Replacement circuit breaker assemblies – see page 627 Circuit breaker panelboard – open view Electrical Rating Ranges: Size Ranges: • • • • Panel Designation N2PB1426 N2PB2426 Circuit breakers Single-pole – 120/240VAC max. Two-pole – 120/240VAC max. Trip ratings – 15, 20 and 30 amp. Max. No. of Breakers Single-Pole Two-Pole 12 24 6 12 †Watertight, weatherproof with door closed. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 669 N2PB Circuit Breaker Panelboards 1A Factory Sealed Single & Two-Pole Breakers Watertight† Cl. I, Div. 2, Groups C, D Weatherproof Cl. II, Div. 2, Groups F, G Corrosion-Resistant Dust-tight NEMA 3, 7CD (Div. 2), 9FG (Div. 2), 12 Ordering Information Panelboards are available with 15, 20 or 30 ampere circuit breakers. To order a panelboard with all breakers of the same rating, add the desired rating as a suffix to the Cat. No. For example, the 12 circuit N2PB2426-2512 panelboard with all the circuit breakers rated 20 amperes would be ordered as N2PB2426-2512-20. Panelboards listed below can also be furnished with an assortment of single-pole and two-pole breakers and breaker ratings. To order, the quantities of breakers and ampere ratings are added as suffixes to the Cat. No. The total number of poles will determine the panel size (24 poles max.), and the wiring systems must be compatible when combining single- and two-pole circuit breakers. Example: N2PB2426-2512-15 with threepole, 100 amp main circuit breaker would be ordered as N2PB2426-2512-15-3M100. If two-pole main is required, change the number 3 to 2. If a lower trip rating is required, the number will change accordingly. Main breaker housing is positioned on top of panel similar to D2PB main. (See Section 1A.) For example, a typical N2PB panelboard with a combination of 5 single-pole 20 ampere, 3 single-pole 30 ampere, and 4 two-pole 30 ampere breakers would be ordered as N2PB2426-2508-520-330-80430. The total number of poles is 16 and wiring systems 25 and 8 are compatible 4 wire, 3 phase. The N2PB with a main breaker is available up to 100 amps. N2PB with main breaker, add appropriate suffix. 1A Enclosures with Single-Pole Circuit Breakers Max. No. of Breakers 1 Pole 2 Poles 6 8 10 12 4 5 6 12 14 16 18 20 22 24 6 7 8 9 10 11 12 Enclosure Only Cat. #* Panel Size Enclosures with Two-Pole Circuit Breakers Wiring System 24 Wiring System 25 Wiring System 3 Wiring System 8 Mains: 3-Wire Mains: 4-Wire, 3-Phase Branches: 2-Wire, 1-Phase Solid Neutral Cat. #‡ Mains: 3-Wire Solid Neutral Cat. #‡ Mains: 4-Wire, 3-Phase Branches: 3-Wire, 1-Phase Solid Neutral Cat. #‡ N2PB1426 804 ➀ N2PB1426 805 ➀ N2PB1426 806 ➀ Branches: 2-Wire Main Lug Solid Neutral Size Cat. #‡ Branches: 3-Wire N2PB1426 N2PB1426 14 x 26 x 81/ 2 N2PB1426 1 / 0 N2PB1426 N2PB1426 2406 2408 2410 2412 ➀ ➀ ➀ ➀ N2PB1426 N2PB1426 N2PB1426 N2PB1426 2506 2508 2510 2512 ➀ ➀ ➀ ➀ N2PB1426 304 ➀ N2PB1426 305 ➀ N2PB1426 306 ➀ N2PB2426 N2PB2426 N2PB2426 N2PB2426 4 / 0 N2PB2426 N2PB2426 N2PB2426 N2PB2426 2412 2414 2416 2418 2420 2422 2424 ➀ ➀ ➀ ➀ ➀ ➀ ➀ N2PB2426 N2PB2426 N2PB2426 N2PB2426 N2PB2426 N2PB2426 N2PB2426 2512 2514 2516 2518 2520 2522 2524 ➀ ➀ ➀ ➀ ➀ ➀ ➀ N2PB2426 N2PB2426 N2PB2426 N2PB2426 N2PB2426 N2PB2426 N2PB2426 24 x 26 x 81/ 2 Note on Hubs: Hubs must be ordered separately. See page 677 for listing. ➀ Add ampere rating. See ordering information above. † Watertight, weatherproof with door closed. ‡ See page 677 for wiring diagrams. *Accommodates D2CB breakers. Includes complete interiors, wiring system must be specified. Example: N2PB2426 with wiring system 25 would be ordered as N2PB2426-25. 670 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 306 307 308 309 310 311 312 ➀ ➀ ➀ ➀ ➀ ➀ ➀ N2PB2426 N2PB2426 N2PB2426 N2PB2426 N2PB2426 N2PB2426 N2PB2426 806 807 808 809 810 811 812 ➀ ➀ ➀ ➀ ➀ ➀ ➀ N2PB Circuit Breaker Panelboards Factory Sealed Single & Two-Pole Breakers Watertight† Cl. I, Div. 2, Groups C, D Weatherproof Cl. II, Div. 2, Groups F, G Corrosion-Resistant Dust-tight NEMA 3, 7CD (Div. 2), 9FG (Div. 2), 12 1A Dimensions In Inches: 1A N2PB Cat. # Nominal Inside Dimensions nw nl N2PB1426 N2PB2426 14 24 26 26 nd Door Opening Dimensions dw dl Mounting Dimensions mw ml Alternate Mounting Dimensions mwa mla 81/ 2 81/ 2 911/ 16 1911/ 16 117/ 8 213/ 4 153/ 8 251/ 4 2311/ 16 2311/ 16 271/ 4 271/ 4 233/ 4 233/ 4 Not to be used for construction purposes unless approved. † Watertight, weatherproof with door closed. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 671 1A NEMA 1, 3, 3R, 4, 4X, 12 NEMA PB1 UL/cUL Listed XLPB Industrial Panelboards Applications: 1A XLPB Industrial Panelboards are used / installed: • In areas made corrosive due to the presence of chemicals, salt water, and/or moisture • In locations where rough usage, moisture, dust, dirt, and corrosion are a problem • In areas subject to weather, dampness, or wash down requirements • To provide, in one compact unit, a centrally controlled switching system for a large number of feeder or branch circuits • For branch power distribution and circuit protection of motors, valves, pumps, lighting, heat tracing, receptacles, etc. • In indoor and outdoor installations • To house thermal-magnetic circuit breakers that provide disconnect means, short circuit protection, and thermal time delay overload protection XLPB Panelboard Closed Features and Benefits: • Heavy-duty welded mounting feet provide ease of installation (customer can easily support the panel with bottom mounting feet, while fastening the top feet) • High quality foam-in-place gasket prevents ingress of water and corrosive agents, reducing panel failure due to moisture/corrosion • An integral drainage channel allows for opening the panel door without moisture or dust seeping into panel from the top side of the enclosure • An internal/external ground stud assembly enables rapid and reliable protective ground connection • Industrial grade NEMA 4X panel designed for harsh environments provides long product life Standard Materials & Finishes: Electrical Ratings: • 120/208, 240, 277/480, 480, and 347/600, 600 voltage panels • 100 and 225 amp rated chassis • Isolated neutral and ground bars • Main breakers up to 225 amps • 12, 18, 24, and 42 circuit panels • 10kAIC • 316L stainless steel or painted sheet steel • Eaton Pow-R-Line™ chassis • Eaton Cutler-Hammer™ circuit breakers • Stainless steel hardware • High integrity foam-in-place gasket • Industrial laminate insulate dead-front cover • SS316 quarter-turn screw driver entry standard Panel Capacity: With Main Breaker Certifications and Compliances: • NEMA 1, 3, 3R, 4, 4X, 12 • NEMA PB1 • UL508A Listed / cUL Certified (CAN/CSA C22.2, No. 14) (UL File E246968) • UL67 components • UL489/CAN/CSA C22.2, No. 5 circuit breakers XLPB Panelboard Open 120/208V (3P 120/240V (1P 277/480V (3P 347/600V (3P CSA ONLY 4W) 3W) 4W)* 4W) With Panel Main Size Lug 2-Pole 3-Pole Main Capacity Main Capacity Available w/GFI/EPD Branch Protection A B C D Up Up Up Up Up Up Up Up 12 18 24 42 10 16 22 40 9 15 21 39 Up Up Up Up to to to to 100 100 100 100 Amp Amp Amp Amp *277V EPD Branch Protection potentially available - single phase only (requires 2 breaker spaces) 672 www.crouse-hinds.com US: 1-866-764-5454 480V (3P 3W) 277/480V (3P 4W) 600V (3P 3W) 347/600 (3P 4W) CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business to to to to 225 225 225 225 Amp Amp Amp Amp to to to to 240V* 240V* 240V* 240V* XLPB Industrial Panelboards NEMA 1, 3, 3R, 4, 4X, 12 NEMA PB1 UL/cUL Listed 1A Ordering Information: Example: Example would be ordered as: • NEMA 4X stainless steel • 120/208 VAC 3-phase • (8) 1-pole, 20 amp circuit breakers • 3-pole, 100 amp main • Bottom entry (inverted) 1. Panel Type XLPB XLPB A S 2 3 08 *08120 -3M100 -I 2. Size Enclosure A = 12 circuit panelboard B = 18 circuit panelboard C = 24 circuit panelboard D = 42 circuit panelboard 3. Enclosure Material Type S = stainless steel P = painted steel 4. Voltage 2 = 120/208, 240 4 = 480/277, 480 6 = 347/600 5. Phase 1 = single phase 3 = 3 phase 1A 6. Total Number of Branch Circuits Refer to step 2 for maximum number of branch circuits per enclosure size. Number of branch circuits equals combined number of branch circuit breaker poles - i.e. qty. (8) 1-pole, 20 amp breakers = 08 poles Option: Ambient compensated breakers for 50ºC, add suffix V after total number of branch circuits 7. Branch Breaker Series *Quantity, Pole, Amp *08120 = qty. (08), 1-pole, 20 amp circuit breakers Option: For GFI circuit breakers, add suffix G after Total Number of Branch Circuits and Branch Breaker Series (ex. XLPBAS2308G*04120*04115G-3M100 Option: For EPD circuit breakers, add suffix E after Total Number of Branch Circuits and Branch Breaker Series (ex. XLPBAS2308E*04120*04115E-3M100 8. Main Breaker 2 or 3 pole, 15 to 225A Example: 3M100 = 3-pole main breaker, 100 amp 9. Options (see Options Section for more information) Breathers and drains Gland plates Bottom feed inverted panelboard Enclosure access handles Key entry door access External operators Lighting contactor www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 673 1A NEMA 1, 3, 3R, 4, 4X, 12 NEMA PB1 UL/cUL Listed XLPB Industrial Panelboards Options: Description Suffix Where Added Ambient compensated breakers for 50ºC .......................................................V After Total Number of Branch Circuits After Total Number of Branch Circuits and after GFI - 5mA ground fault protection ..................................................................G specific Branch Breaker Series After Total Number of Branch Circuits and after EPD - 30mA equipment protection ...................................... ...........................E specific Branch Breaker Series Breathers and drains to reduce moisture and corrosion.........................S756V End of Catalog Number Gland plates for ease of installation ..................................... ........................GP End of Catalog Number Bottom feed inverted panelboard .....................................................................I End of Catalog Number Enclosure access handles ..........................................................................HLD End of Catalog Number Key entry door access ................................................................................KED End of Catalog Number External operators ...................................................................Contact Factory Lighting contactor ...................................................................Contact Factory Dimensions: MOUNTING PLATE DIMENSIONS (IN INCHES) A B C D 24 X 20 22" 18" 20" 16" 32 X 20 30" 18" 28" 16" 38 X 20 36" 18" 34" 16" 44 X 20 42" 18" 40" 16" ENCLOSURE SIZE BOTTOM SIDE B C 1A MOUNTING PLATE B D B E F H 24 X 20 X 07 24" 20" 7 3/16" 25 1/4" 14" 12" 6" 32 X 20 X 07 32" 20" 7 3/16" 33 1/4" 14" 17 3/4" 7 1/8" 38 X 20 X 07 38" 20" 7 3/16" 39 1/4" 14" 23 5/8" 7 3/16" 44 X 20 X 07 44" 20" 7 3/16" 45 1/4" 14" 29 1/2" 7 1/4" 7/16" 2-OFF ADDITIONAL HOLES ON CENTRE LINE FOR 38/20 & 44/20. www.crouse-hinds.com US: 1-866-764-5454 F A C PROTECTION REMARK TO DIN 34 MUST BE OBSERVED 674 4-OFF 7mm THRU HOLES FOR ALL SIZES LEFT SIDE C D A H PLAN VIEW OF BOX WITH LID FITTED DIMENSIONS (IN INCHES) A 7/16" E B CAN: 1-800-265-0502 M10 INT/EXT EARTHSTUD Copyright© 2013 Eaton’s Crouse-Hinds Business C D NLP Circuit Breaker Panelboards With QO® Breakers Applications: Electrical Rating Ranges: • NLP panelboards are for use in central control and protection of a large number of feeder or branch circuits and for housing circuit breakers. • QO® circuit breakers, single or two-pole 120/240VAC; three-pole 240VAC • Trip ratings: 10 to 70 amps, single-pole 10 to 70 amps, two-pole 10 to 60 amps, three-pole • Qwik-Gard® GFI circuit breakers: Single-pole – 120 VAC 15 to 30 amps; Two-pole – 120/240VAC 15 to 50 amps Features: • Enclosures are made of Krydon® high impact strength fiberglass-reinforced polyester material with excellent corrosion resistance and stability to heat • Enclosure access door provided with stainless steel thumb screws for easy access • Access door may be padlocked to prevent unauthorized access • Standard with plug-on circuit breakers Certifications and Compliances: Options: • Assortment of circuit breaker trip ratings – specify • Assortment of single, two and three-pole circuit breakers – specify • Wiring system other than those listed – specify • Ground fault interrupter – circuit breakers with built-in ground fault circuit interrupters can be provided. These interrupters cause the breaker to open when a ground fault occurs. Suffix "GFI" should be added after each circuit breaker rating to be supplied with ground fault interrupters Ordering Information: Panelboards are available with 10, 15, 20, 25, 30, 35, 40, 45, 50, 60 or 70 ampere circuit breakers. To order a panelboard with all breakers of the same rating, add the desired rating as a suffix to the Cat. No. For example, the 12 circuit NLPQ1426-2512 with all circuit breakers rated 20 amperes would be ordered as NLPQ1426-2512-20. Panelboards can be furnished with an assortment of breaker ratings. Where all circuit breakers have the same number of poles, assortments may be ordered by adding the quantities and ampere ratings as suffixes to the Cat. No. For example, the 12 circuit NLPQ1426-2512 with six 15 ampere, four 40 ampere and two 50 ampere singlepole circuit breakers would be ordered as NLPQ1426-2512-615-440-250. 1A • NEMA 3 and 12 • UL Standard: 67 1A Corrosion-Resistant Dust-tight Watertight* Weatherproof NEMA 3, 12 Example: An NLPQ panelboard using wiring system 24 with four 15 ampere breakers, two 40 ampere and four 50 ampere breakers and two 15 ampere breakers, one 25 ampere breaker, and one 30 ampere breaker with GFI – Catalog No. NLPQ1426-2414-415-240-450-215GFI125GFI-130GFI Main Lug Only 3 Wire Branches (200A MLO) Size Ranges: Max. No. of Branch Circuit Breakers Mains Rating 1-Pole 2-Pole 3-Pole 3w 4w 3w 4w 3w 4w Panel Type Main Lug Only NLPQ1426 200A 24 30 12 14 – 10 No of Circuits 4 6 8 10 12 14 16 18 20 22 24 Enclosure Only NLPQ1426 NLPQ1426 NLPQ1426 NLPQ1426 NLPQ1426 NLPQ1426 NLPQ1426 NLPQ1426 NLPQ1426 NLPQ1426 NLPQ1426 1 1 1 1 1 1 1 1 1 1 1 Main Lug‡ Amps 200 200 200 200 200 200 200 200 200 200 200 Enclosures with QON Interiors and QO® Branch Circuit Breakers 1-Pole Branch Circuit 2-Pole Branch Circuit Breakers Breakers Wiring System 24† Wiring System 3† NLPQ1426 2404 ➀ NLPQ1426 0304 ➀ NLPQ1426 2406 ➀ NLPQ1426 0306 ➀ NLPQ1426 2408 ➀ NLPQ1426 0308 ➀ NLPQ1426 2410 ➀ NLPQ1426 0310 ➀ NLPQ1426 2412 ➀ NLPQ1426 0312 ➀ NLPQ1426 2414 ➀ — NLPQ1426 2416 ➀ — NLPQ1426 2418 ➀ — NLPQ1426 2420 ➀ — NLPQ1426 2422 ➀ — NLPQ1426 2424 ➀ — * Watertight, weatherproof with door closed. ➀ Insert branch circuit breaker rating desired 10, 15, 20, 25, 30, 35, 40, 45, 50, 60 or 70 amp. † See page 677 for wiring diagrams. QO and Qwik-Gard are registered trademarks of Square D Company. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 675 NLP Circuit Breaker Panelboards With QO® Breakers 1A Corrosion-Resistant Dust-tight Watertight* Weatherproof NEMA 3, 12 4 Wire Branches (200A MLO) No of Circuits 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Enclosure Only NLPQ1426 3 NLPQ1426 3 NLPQ1426 3 NLPQ1426 3 NLPQ1426 3 NLPQ1426 3 NLPQ1426 3 NLPQ1426 3 NLPQ1426 3 NLPQ1426 3 NLPQ1426 3 NLPQ1426 3 NLPQ1426 3 NLPQ1426 3 Main Lug‡ Amps 200 200 200 200 200 200 200 200 200 200 200 200 200 200 Enclosures with QON Interiors and QO® Branch Circuit Breakers 1-Pole Branch Circuit Breakers 2-Pole Branch Circuit Breakers 3-Pole Branch Circuit Breakers Wiring System 25† Wiring System 28† Wiring System 11† NLPQ1426 2504 ➀ NLPQ1426 2804 ➀ NLPQ1426 1104 ➀ NLPQ1426 2506 ➀ NLPQ1426 2806 ➀ NLPQ1426 1106 ➀ NLPQ1426 2508 ➀ NLPQ1426 2808 ➀ NLPQ1426 1108 ➀ NLPQ1426 2510 ➀ NLPQ1426 2810 ➀ NLPQ1426 1110 ➀ NLPQ1426 2512 ➀ NLPQ1426 2812 ➀ — NLPQ1426 2514 ➀ NLPQ1426 2814 ➀ — NLPQ1426 2516 ➀ — — NLPQ1426 2518 ➀ — — NLPQ1426 2520 ➀ — — NLPQ1426 2522 ➀ — — NLPQ1426 2524 ➀ — — NLPQ1426 2526 ➀ — — NLPQ1426 2528 ➀ — — NLPQ1426 2530 ➀ — — The NLP and NLPQ panelboards accommodate Square D NQOD and QON interiors as follows. Enclosure 3 Wire Branches 4 Wire Branches NLPQ1426 QON124L200I QON330L200 When ordering enclosures only, interiors and circuit breakers are not included and must be ordered separately from Square D. 1A Note: Dimensions In Inches: NLP Cat. # Nominal Inside Dimensions nw nl NLP1426 14 26 nd Door Opening Dimensions dw dl Mounting Dimensions mw ml Alternate Mounting Dimensions mwa mla 81/2 911/16 117/8 153/8 2311/16 271/4 Not to be used for construction purposes unless approved. * Watertight, weatherproof with door closed. ➀ Insert branch circuit breaker rating desired, 10, 15, 20, 25, 30, 35, 40, 45, 50, 60 or 70 amp. ‡ 200A QON main lugs are #4/0 Cu/Al. † See page 677 for wiring diagrams. Note: Hubs, grounding plates and bushings must be ordered separately. See page 677 for listing. 676 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 233/4 1A Accessories Hubs Conduit Size Hole Size Hub Cat. # Krydon® material hubs for conduit entrances, in sizes 1/2" through 3" are available for factory or field installation in all enclosures made of Krydon material. For factory installation, send drawing showing sizes and locations of hubs. Furnished with and gaskets to assure. /2 /4 1 11/4 11/2 2 21/2 3 7 /8 11/8 13/8 13/4 2 21/2 3 35/8 NHUB1 NHUB2 NHUB3 NHUB4 NHUB5 NHUB6 NHUB7 NHUB8 1 3 Standard Materials: • Up to 11/2" – Krydon material with steel interiors • 2", 21/2" and 3" – Krydon material with Feraloy® iron alloy interiors Grounding Plates and Grounding Bushings Standard Finishes: • Krydon material – natural • Steel – electrogalvanized and bleached chromate • Feraloy iron alloy – electrogalvanized • Grounding plates – steel • Grounding bushings – steel with thermoplastic insulating throat Standard Finishes: • Steel – electrogalvanized Conduit Size Grounding Plate Cat. # Grounding Bushing Cat. # /2 /4 1 11/4 11/2 2 21/2 3 GP1 GP2 GP3 GLS1 GLS2 GLS3 GLS4 GLS5 GLS6 GLS7 GLS8 1 3 1A Standard Materials: Grounding Plates (1/ 2" through 1") and insulated bushings (1/ 2" through 3") permit use of the conduit as the grounding circuit. Both types have set screws and ground-wire terminals. Wiring Diagrams for Circuit Breaker Panelboards System 3 Mains—3-Wire Branches—3-Wire Breakers—2-Pole Solid Neutral System 8 Mains—4-Wire, 3-Phase Branches—3-Wire, 1-Phase Breakers—2-Pole Solid Neutral System 11 Mains—4-Wire, 3-Phase Branches—4-Wire, 3-Phase Breakers—3-Pole Solid Neutral System 24 Mains—3-Wire Branches—2-Wire Breakers—Single-Pole Solid Neutral System 25 Mains—4-Wire, 3-Phase Branches—2-Wire Breakers—Single-Pole Solid Neutral System 28 Mains—4-Wire, 3-Phase Branches—3-Wire, 1-Phase Breakers—2-Pole Solid Neutral www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 677 1A 1A 678 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 2A Switches Hazardous and Non-hazardous Description Page No. Application/Selection see page 680 Enclosed Switches Heavy Duty FLS N2RS WST/W2ST see page 685 see page 690 see page 696 General Use Snap Switches EFD, EFDC, EDS, EDSC FSPC GUSC Manual Contactors see pages 694–695 see page 692 see page 691 see page 700 Disconnect Switches see page 681 see page 682 see page 683 see pages 698–699 see pages 701–702 see pages 686–689 Light Switch GHG273 www.crouse-hinds.com US: 1-866-764-5454 see page 693 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 679 2A EID (Non-fused) EID (Fused) EBM NRS NST GHG 2A Switches Application and Selection Quick Selector Chart Applications: • Switches and enclosures are used in hazardous and non-hazardous areas to disconnect motor, lighting and other circuits and prevent arcing of the enclosed switch from igniting hazardous atmospheres. Quick Selector Chart Options: Considerations for Selection: Enclosure Location: • NEC/CEC and NEMA/EEMAC compliances for hazardous areas and/or wet and dirty locations Electrical: • Consistency with the functions to be performed Application: • Selection of appropriate switch and operating mechanism • Optional material and finishes available for highly corrosive atmospheres • Various hub sizes are available to suit particular applications Electrical Rating NEC/CEC & NEMA/EEMAC Compliances NEMA/EEMAC: 3R, 4, 12 Max. Amps 100 Max. Volts 600VAC 250VDC Max. HP 75 Switch Type Visible blade Heavy duty Fused or Unfused Fused & unfused EDS, EDSC, EFD, EFDC Cl. I, Div. 1 & 2, Groups B, C, D; Cl. II, Div. 1, Groups E, F, G; Cl. II, Div. 2, Groups F, G; Cl. III; NEMA/EEMAC: 3, 7BCD, 9EFG, 12 30 277VAC 2 General use snap Unfused FSPC Cl. I, Div. 1 & 2, Groups A, B, C, D; Cl. II, Div. 1, Groups E, F, G; Cl. II, Div. 2, Groups F, G; Cl. III; NEMA/EEMAC: 3, 7ABCD, 9EFG, 12 20 277VAC 2 General use snap Unfused GUSC Cl. I, Div. 1 & 2, Groups C, D; Cl. II, Div. 1, Groups E, F, G; Cl. II, Div. 2, Groups F, G; Cl. III; NEMA/EEMAC: 3, 7CD, 9EFG, 12 30 600VAC 2 General use snap Unfused FLS Cl. I, Div. 1 & 2, Groups C, D; Cl. II, Div. 1, Groups E, F, G; Cl. II, Div. 2, Groups F, G; Cl. III; NEMA/EEMAC: 3, 4, 7CD, 9EFG, 12 100 600VAC 50 Visible blade Disconnect Unfused EBM Cl. I, Div. 1 & 2, Groups B, C, D; Cl. II, Div. 1, Groups E, F, G; Cl. II, Div. 2, Groups F, G; Cl. III; NEMA/EEMAC 3, 4, 7BCD, 9EFG, 12 100 600VAC 75 Visible blade Disconnect Fused & unfused NRS NEMA/EEMAC: 3, 4X, 12 100 600VAC 75 Rotary - Disconnect Fused & unfused N2RS Cl. I, Div. 2, Groups B, C, D; NEMA: 3, 4X, 12 100 600VAC 60 Rotary - Disconnect Unfused NST NEMA: 3, 4X, 12 200 600VAC 250VDC 125 Visible blade Disconnect Fused & unfused Manual Contactors NEMA/EEMAC: 3R 30 600VAC 15 Contacts, snap Unfused GHG Cl. I, Div. 2, Groups A, B, C, D; Cl. II, Div. 1, Groups E, F, G; Cl. I, Zones 1 & 2, Ex de IIB+H, Ex de IIC 180 600VAC 150 Rotary, snap Unfused EID Cl. Cl. Cl. Cl. 400 600VAC 350 Rotary - Disconnect Fused & unfused 2A Switch Enclosure WST 680 I, Div. 1 & 2, Groups B, C, D; I, Zones 1 & 2; II, Div. 1, Groups E, F, G; III www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business EID Disconnect Assembly Cl. I, Div. 1 & 2, Groups B, C, D Cl. I, Zones 1 & 2 Cl. II, Div. 1, Groups E, F, G Cl. III Non-fused Applications: • Provides an explosionproof disconnect switch assembly for hazardous area electrical systems • Incorporates Eaton's Crouse-Hinds' high integrity manufacturing standards for reliability and safety in a compact, space-efficient NEMA 4 enclosure Features and Benefits: 2A Certifications and Compliances: • • • • • Class I, Divisions 1 & 2, Groups B, C, D Class I, Zones 1 & 2 Class II, Division 1, Groups E, F, G Class III Enclosure Type 3, 3R, 4 or 4X*, 7BCD, 9EFG • UL Standard 1203 • cUL to CSA C22.2 No. 30 Standard Materials: • Body and Cover—Copper-free Aluminum • Gasket—Neoprene • Cover Bolts—Steel • Hinges—Stainless Steel • Mounting Plate Sheet—Aluminum • Rotary Actuating Handle—Aluminum Standard Finishes: • Copper-free Aluminum—Natural • Steel—Electro-galvanized Electrical Ratings: Weights: EIDA EIDB 36 lbs 62 lbs 16 kg 28 kg Options: Description Suffix Auxiliary Contact (single block) ....... S784 Auxiliary Contacts (two blocks) ....... S785 Breather and Drain .......................... S756V Epoxy Powder Coat Finish (external only) .................................. S752 Epoxy Powder Coat Finish (internal and external) ...................... S753 External Ground Lug ....................... S214 Non-fused HP Rating at: Amps 200V 208V 240V 480V 600V 30 60 100 200 400 10 20 25 - 10 20 25 - 10 20 30 75 125 20 40 50 150 250 30 40 50 200 350 Ordering Information: Switch Rating Enclosure Enclosure (Amps) Only with Switch 30 60 100 200 400 EIDA EIDA EIDB - EIDA3030 EIDA3060 EIDB3100 EIDC3200‡ EIDD3400‡ Dimensions: EIDA EIDB A 9.65" 245mm 11.75" 298mm B 5" 127mm 7" 178mm C 10.47" 266mm 12.53" 318mm D 11.13" 283mm 15.13" 384mm E 12.47" 317mm 16.53" 420mm F 2.75" 2.75" *When ordered with S752 or S753 suffix. **When ordered with S756V suffix. †For both drains and auxiliary contacts, please contact factory. ‡Contact Customer Service for additional specifications. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 681 2A • Can be ordered as enclosure only, allowing for field installation of switch while maintaining product certification • NEMA 4X breather and drain** provides a moisture control solution in hose-down applications • Small, compact footprint - less mounting space required • Large red painted aluminum rotary handle operator mounted on cover assembly provides rugged, reliable performance in the field and allows for the position of the switch to be easily identified from a distance • Neoprene cover gasket provides UL Type 4 (hosetight) environmental rating • Detachable/adjustable mounting feet provide flexible mounting alternatives for ease of installation; no need to replace the entire enclosure if a mounting foot is broken • Stainless steel hinges provide easy access to inside of enclosure for wiring and maintenance • (2) Conduit entries, one on top and one on bottom (EIDA—1" NPT entries, EIDB—1 1/2" NPT entries) for easy top or bottom feed of conductors • (2) 1/ 2" NPT conduit entries, one on top and one on bottom, for field addition of breather and/or drain or for use with auxiliary contacts; †holes come plugged with Eaton's Crouse-Hinds PLG explosionproof as standard • Provides lockout/tagout capability which complies with OSHA requirements, allowing for locking in the ON or OFF position for standard maintenance checks • Complies with NEC Article 312 wire bending requirements for max gauge wire, allowing for easy and safe installation, and reliable operation of product UL/cUL Listed Enclosure Type 3, 3R, 4, 4X*, 7BCD, 9EFG 2A EID Disconnect Assembly Fused Applications: • Provides an explosionproof disconnect switch assembly for hazardous area electrical systems • Incorporates Eaton's Crouse-Hinds' high integrity manufacturing standards for reliability and safety in a compact, spaceefficient NEMA 4 enclosure 2A Features and Benefits: • NEMA 4X breather and drain** provides a moisture control solution in hosedown applications • Small, compact footprint - less mounting space required • Large red painted aluminum rotary handle operator mounted on cover assembly provides rugged, reliable performance in the field and allows for the position of the switch to be easily identified from a distance • Neoprene cover gasket provides UL Type 4 (hosetight) environmental rating • Detachable/adjustable mounting feet provide flexible mounting alternatives for ease of installation; no need to replace the entire enclosure if a mounting foot is broken • Stainless steel hinges provide easy access to inside of enclosure for wiring and maintenance • (2) Conduit entries, one on top and one on bottom for easy top or bottom feed of conductors • (2) NPT conduit entries, one on top and one on bottom, for field addition of breather and/or drain or for use with auxiliary contacts; †holes come plugged with Eaton's Crouse-Hinds PLG explosionproof as standard • Provides lockout/tagout capability which complies with OSHA requirements, allowing for locking in the ON or OFF position for standard maintenance checks Cl. I, Div. 1 & 2, Groups B, C, D UL/cUL Listed Enclosure Type 3, 3R, Cl. I, Zones 1 & 2 4, 4X*, 7BCD, 9EFG Cl. II, Div. 1, Groups E, F, G Cl. III Certifications and Compliances: • • • • • Class I, Divisions 1 & 2, Groups B, C, D Class I, Zones 1 & 2 Class II, Division 1, Groups E, F, G Class III Enclosure Type 3, 3R, 4 or 4X*, 7BCD, 9EFG • UL Standard 1203 • cUL to CSA C22.2 No. 30 Standard Materials • • • • • • Body and Cover—Copper-free Aluminum Gasket—Neoprene Cover Bolts—Steel Hinges—Stainless Steel Mounting Plate Sheet—Aluminum Rotary Actuating Handle—Aluminum Standard Finishes: Ordering Information: Switch Rating (Amps) Enclosure with Switch 30 60 100 200 400 EIDAF3030 EIDAF3060 EIDBF3100 EIDCF3200 EIDDF3400 Note: Fuses are not included (Type J recommended). Note: Contact Customer Service for additional specifications. • Copper-free Aluminum—Natural • Steel—Electro-galvanized Options: Electrical Ratings: Fused HP Rating at: Amps 30 60 100 200 400 240V 480V 600V 60 125 15 30 60 125 250 20 50 75 150 350 Description Suffix Auxiliary Contact (single block) . . .S784 Auxiliary Contacts (two blocks) . . . S785 Breather and Drain . . . . . . . . . . . . .S756V Epoxy Powder Coat Finish (external only) . . . . . . . . . . . . . . . . .S752 Epoxy Powder Coat Finish (internal and external) . . . . . . . . . . .S753 External Ground Lug. . . . . . . . . . . . S214 *When ordered with S752 or S753 suffix. **When ordered with S756V suffix. †For both drains and auxiliary contacts, please contact factory. 682 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business EBM Disconnect Switches and Enclosures Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 3R, 4‡, 4X††, 7BCD, 9EFG, 12 600 VAC Heavy Duty Applications: EBM series hinged cover disconnect switches are used: • To disconnect motor, lighting and other circuits. • In locations made hazardous by the presence of flammable gases or vapors or ignitable dusts. • Indoors or outdoors in damp, wet and dirty locations, or in areas where frequent washdowns, heavy rain or water spray is prevalent. • To provide disconnect means and short circuit protection (fusible version). • On switchracks or other assemblies where it is desired that motor control be centrally located. 2A Explosionproof Dust-Ignitionproof Watertight Wet Locations Certifications and Compliances: • NEC/CEC: Class I, Division 1 & 2, Groups B, C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III • UL Standards: UL1203 • High A.I.C. Rating (Interrupting Capacity) - For Class I, Div. 1, Groups C & D only Volt RMS Symm-Amperes 240 480 600 65,000 50,000 25,000 • CSA Standard: C22.2 No. 30 • NEMA: 3, 3R, 4‡, 4X††, 7BCD, 9EFG, 12 Features: Standard Materials: • Body and cover – copper-free aluminum • Operating handle – copper-free aluminum • Operating shaft and bushing – stainless steel • Interior parts – sheet steel, electrogalvanized • Cover bolts, washers and retractile springs – stainless steel • Hinges – stainless steel 2A • Rugged corrosion resistant cast copperfree aluminum construction (less than 0.4 of 1%). • Switch operating handle is located through the right side wall of the body, permits visual confirmation of correct alignment and operation. • Total compliance to the wiring end room requirements of the National Electrical Code. • Semi-clamshell enclosure design, with an external flanged ground joint between body and cover makes interior components more accessible. • Minimum enclosure-to-enclosure spacing with little interference between the opened cover and an adjacent enclosure. • Stainless steel hinges allow the cover to swing well out of the way. • Stainless steel quick release captive hexhead cover bolts. Stainless steel springs provide clear indication that cover bolts are fully retracted from the body. • Switch operating handle can be padlocked in either the "ON" or "OFF" position. • Neoprene cover gasket permanently attached to the cover seals out moisture. • Bodies have top and bottom drilled and tapped conduit entrances for power and conduits. Removable reducers are supplied as standard, to accommodate smaller size conduits. All conduit entrances are plugged. • Tap on mounting feet. Ordering Information: To order an enclosure complete with the disconnect switch, select the catalog number (based on the necessary rating of the switch), from the listing below. Enclosures only, without the disconnect switch, can be ordered. Select the catalog number for the required enclosure from the listing below. Electrical Rating Ranges: • 600 VAC • 30, 60 and 100 Amp Max. HP Rating Amp AC Polyphase Rating 200/240V 440/480V Non-Fusible 30 10 20 60 20 40 100 30 75 550/600V Enclosure DC using 2 poles only With Switch 250V Max. 600VAC Cat. # 25 60 75 71/2 15 25 EBMBB FD W30360 EBMBB FD EBMBB FD W60360 EBMBB FD EBMBD FD W10360 EBMBD FD Fusible 30 — 60 — 100 15 71/2 15 30 5 10 20 EBMBB FD W30361 EBMBB FD EBMBB FD W60361 EBMBB FD EBMBD FD W10361 EBMBD FD 5 15 25 Without Switch Cat. # Options: • For available options, see pages 494–495. ‡ Enclosure not suitable for NEMA 4 or 4X with cover mounted operators. ††With S752 or S753. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 683 Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 3R, 4‡, 4X††, 7BCD, 9EFG, 12 EBM Disconnect Switches and Enclosures 2A 600 VAC Heavy Duty Explosionproof Dust-Ignitionproof Watertight Wet Locations Dimensions 2A In Inches: Dimensions are approximate, not for construction purposes. *1" D & T conduit entry for control conductors supplied with PLG plug top and bottom. **Conduit entrance(s) for power conductors (top and bottom). (All conduit entrance(s) supplied with RE reducer and PLG plug.) G **J Conduit Entry Trade Size D&T† w/RE K L M P 14.46 10.25 2" 1.5" 3.25 3.13 10.25 22.00 14.46 10.25 3" 2.5" 3.25 3.13 10.25 24.50 Enclosure Only Cat. # Enclosure Size Symbol A B C D E F 30 and 60 Amp Frame EBMBB B 25.75 24.75 26.90 6.00 13.03 100 Amp Frame EBMBD D 28.25 27.25 29.40 6.00 13.03 ‡ Enclosure not suitable for NEMA 4 or 4X with cover mounted operators. ††With S752 or S753. †Drilled & Tapped. 684 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business FLS Enclosed Switches Heavy Duty Applications: Standard Materials: FLS heavy duty enclosed switches are used: • In a rigid metallic conduit system for surface mounting adjacent to or remote from equipment being controlled • As disconnect switches for main feed or individual motor control • To prevent arcing of the enclosed switch from causing ignition of a specific hazardous atmosphere, or atmospheres, external to the enclosure • In industrial areas such as chemical plants, oil and gas refineries, paint and varnish manufacturing plants, gasoline bulk loading terminals, grain elevators, grain processing industries, coal processing or handling areas and metal handling or finishing areas where atmosphere may contain hazardous gases and/or dust • In non-hazardous area where sturdy, durable enclosures are required • • • • 2A Explosionproof Dust-Ignitionproof Raintight Wet Locations Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 7CD, 9EFG, 12 Body – copper-free aluminum Cover – copper-free aluminum Shaft – stainless steel Shaft bushings – stainless steel Standard Finishes: • Copper-free aluminum – natural • Stainless steel – natural Options: Description Ground/neutral wire stud provided Breather and Drain Auxiliary switch: 1A, 1B Auxiliary switch: 2A, 2B Suffix S168 S198V S784 S785 Size Ranges: • Hub size – 11/2" through feed with top entry having a PLG5 plug 2A Ordering Information: Features: Furnished with Non-Fusible, Visible Blade Motor Circuit Switch • Enclosed devices are unfused, visible blade motor circuit switches • Rugged cast metal enclosures with mounting lugs and taper tapped hubs with integral bushings, in through feed arrangement • Interior of the enclosures is readily accessible through threaded cover openings at each end, set at an angle to facilitate wiring • Threaded covers and a threaded type operating shaft and bushing provide quick assembly and easy maintenance • A padlock can be used to lock the operating handle in an "ON" or "OFF" position • Body and cover threads treated with lubricant at factory to provide raintightness Switch Ratings Amperes Maximum HP – 3 Phase Volts AC 125 240 480 600 30 60 100 5 10 15 10 20 30 20 40 75 25 60 75 250 VDC Through Feed Hub Size Enclosure With 3-Pole Switch Cat. # 7.5 15 25 11/2" 11/2" 11/2" FLS30364 1 33 FLS60364 1 44 FLS10364 1 55 Dimensions In Inches: Certifications and Compliances: • NEC: Class I, Divisions 1 & 2, Groups C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III • NEMA: 3, 4, 7CD, 9EFG, 12 • UL Standard: 1203 Dimensions are approximate, not for construction purposes. a 71/2 www.crouse-hinds.com b c d e f g 131/8 81/2 93/4 91/8 7 /16 13/4 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 685 2A Explosion Protected Disconnect Switches 10, 20, 40, 80, 125 and 180 Amp 600VAC Non-metallic Enclosure cCSAus Certified Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zones 1 and 2, AEx de IIC, T6 Cl. II, Div. 1, Groups E, F, G (CSA) Cl. II, Div. 2, Groups F, G ATEX Approved Ex de IIC, T6, Zones 1 and 2, IP66 Applications: Explosion Protected Disconnect Switches are used in a metallic conduit or cable system for surface mounting to control motor, lighting, and other circuits and: • For individual motor control • Are used to prevent arcing internal to the enclosed switch from causing ignition of a specific hazardous atmosphere or atmospheres • Are designed for industrial areas such as chemical plants, oil and gas refineries, paint and varnish manufacturing plants, gasoline bulk loading terminals, and finishing areas where sturdy, durable enclosures are required 2A Features: • Explosion protected factory sealed motor circuit switches. • Innovative break-line in cover allows full wiring access, making installation quick and easy. • High-impact enclosure is designed for excellent corrosion resistance and will not warp from hot or cold water. • Tongue-in-groove seal guarantees IP66 rating and eliminates possibility of accidental opening or leakage. • Lockable handle meets OSHA lockout/ tagout requirements. • Molded-in-place mounting feet provide a water channel between wall and enclosure. • Large rotary handle provides easy gripping with gloved hands. • Captive cover screws prevent water exposure and possible corrosion. Standard Materials: • Enclosure 10A: Impact-resistance thermoplastic 20A – 180A: Fiberglass-reinforced polyester Non-metallic, corrosion resistance Increased safety Ex-e protection Impact Resistance NEMA 4X, IP66 Protection Enclosure meets UL 94-V0 UV Rated • Enclosure Gasket – Silicon • Handle – Impact-resistant thermoplastic • Cover Screws – Stainless steel • Conduit Entries: Zinc Myers™ Hubs Certifications and Compliances: Electrical Rating Ranges: • • • • • • • • • • • Switches: Horsepower Ratings: cCSAus Certified Class I, Division 2, Groups A, B, C, D Class I, Zones 1 and 2, AEx de IIC, T6 Class II, Division 1, Groups E, F, G (CSA) Class II, Division 2, Groups F, G ATEX Approved - PTB Ex de IIC, T6, Zones 1 and 2A, IP66 GOST-R and GOST-K CSA Standard: C22.2 No.14 NEMA 4X IP66 686 www.crouse-hinds.com US: 1-866-764-5454 GHG GHG GHG GHG GHG GHG 261 262 263 264 265 266 CAN: 1-800-265-0502 10A 20A 40A 80A 125A 180A 240 VAC 600 VAC 0.75 14.3 20 50 40 40 – 12.2 15 30 75 75 Copyright© 2013 Eaton’s Crouse-Hinds Business cCSAus Certified Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zones 1 and 2, AEx de IIC, T6 Cl. II, Div. 1, Groups E, F, G (CSA) Cl. II, Div. 2, Groups F, G ATEX Approved Ex de IIC, T6, Zones 1 and 2, IP66 Explosion Protected Disconnect Switches 10, 20, 40, 80, 125 and 180 Amp 600VAC Non-metallic Enclosure 2A Ordering Information: 10 AMP 20 AMP Pole 3 Pole 3 Pole 6 Pole 3 Pole 6 Pole Rated Voltage 500 V 690 V 690 V 690 V 690 V Auxiliary Contact 1 NO, making – lagging breaking – leading 1 NO, making – lagging breaking – leading 1 NC 1 NO, making – lagging breaking – leading 1 NC Auxiliary Connection 14 AWG 2 x 2.5 mm2 12 AWG 2 x 4 mm2 12 AWG 2 x 4 mm2 12 AWG 2 x 16 mm2 12 AWG 2 x 16 mm2 Connection Terminals 14 AWG 12 AWG 12 AWG 6 AWG 6 AWG Conduit Entries 1 x 3/4" 2 x 3/4" 2 x 3/4" 2 x 3/4" 2 x 1" Cat. # GHG 261 0005 L0002 GHG 262 2301 L0003 GHG 262 2601 L0002 GHG 263 2301 L0002 Weight 0.55 kg 1.5 kg 2.3 kg Dimensions See Figure 1 See Figure 2 See Figure 3 Wall Mounting Plate GHG6101953R0101 GHG 610 1953 R0104 GHG 610 1953 R0118 GHG 610 1953 R0118 1.2 lbs. 40 AMP 3.3 lbs. 5.1 lbs. 2.3 kg 80 AMP GHG 263 0050 L0002 5.1 lbs. 6.5 kg See Figure 4 14.3 lbs. See Figure 5 not required 180 AMP 3 Pole 6 Pole 3 Pole 3 Pole Rated Voltage 690 V 690 V 690 V 690 V Auxiliary Contact 1 NO, making – lagging breaking – leading 1 NC 1 NO, making – lagging breaking – leading 1 NO, making – lagging breaking – leading Auxiliary Connection 12 AWG 2 x 50 mm2 12 AWG 2 x 50 mm2 12 AWG 1 x 70 mm2 12 AWG 1 x 120 mm2 4 / 0 AWG 2A 125 AMP Pole Connection Terminals 2 AWG 2 AWG 2 / 0 AWG Conduit Entries 2 x 11/2" 2 x 11/2" 2 x 11/2" 2 x 2" Cat. # GHG 264 0020 L0017 GHG 264 0021 L0002 GHG 265 0010 L0003 GHG 266 0006 L0002 Weight 6.5 kg 9.0 kg 16.0 kg 16.5 kg Dimensions See Figure 6 See Figure 7 See Figure 8 See Figure 8 Wall Mounting Plate not required not required not required not required 14.3 lbs. 19.8 lbs. 35.2 lbs. 36.3 lbs. For Variable Speed, Three Phase Drives 20 AMP 40 AMP Pole 3 Pole 3 Pole 3 Pole Rated Voltage 690 V 690 V 690 V Auxiliary Contact 1 NO, making – lagging breaking – leading 1 NO, making – lagging breaking – leading 1 NO, making – lagging breaking – leading Auxiliary Connection 12 AWG 2 x 4 mm2 6 AWG 2 x 16 mm2 2 AWG 2 x 35 mm2 Connection Terminals 12 AWG 6 AWG Conduit Entries 2 x /4" 1 x 1" + 1 x /2" 1 x 11/2" + 1 x 1/2" Cat. # GHG 262 0014 L0001 GHG 263 0053 L0001 GHG 264 0024 L0001 Weight 1.6 kg 2.3 kg 3.5 kg Dimensions See Figure 9 See Figure 10 See Figure 11 Wall Mounting Plate GHG 610 1953 R0118 GHG 610 1953 R0118 GHG6101953R0110 3 80 AMP 2 AWG 1 3.5 lbs. 5.1 lbs. 7.7 lbs. Switches can be mounted directly onto a wall. The optional wall mounting plate offers a more convenient method of mounting. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 687 2A Explosion Protected Disconnect Switches 10, 20, 40, 80, 125 and 180 Amp 600VAC Non-metallic Enclosure cCSAus Certified Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zones 1 and 2, AEx de IIC, T6 Cl. II, Div. 1, Groups E, F, G (CSA) Cl. II, Div. 2, Groups F, G ATEX Approved Ex de IIC, T6, Zones 1 and 2, IP66 Dimensions In Inches: 2A Figure 1 - 10 Amp, 3 Pole 688 Figure 2 - 20 Amp, 3 Pole Figure 3 - 20 Amp, 6 Pole Figure 4 - 40 Amp, 3 Pole Figure 5 - 40 Amp, 6 Pole Figure 6 - 80 Amp, 3 Pole Figure 7 - 80 Amp, 6 Pole www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business cCSAus Certified Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zones 1 and 2, AEx de IIC, T6 Cl. II, Div. 1, Groups E, F, G (CSA) Cl. II, Div. 2, Groups F, G ATEX Approved Ex de IIC, T6, Zones 1 and 2, IP66 Explosion Protected Disconnect Switches 10, 20, 40, 80, 125 and 180 Amp 600VAC Non-metallic Enclosure 2A Dimensions In Inches: 2A Figure 8 - 125 Amp, 3 Pole 180 Amp, 3 Pole Figure 9 - 20 Amp, 3 Phase Variable Speed Figure 10 - 40 Amp, 6 Phase Variable Speed Figure 11 - 80 Amp, 3 Phase Variable Speed www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 689 2A Cl. I, Div. 2, Groups B, C, D NEMA 3, 4X, 7 (B, C, D Div. 2), 12 Watertight Dust-tight Factory Sealed N2RS Enclosed Switches 2A Heavy-Duty Applications: Standard Materials: N2RS heavy-duty enclosed switches are used: • In a rigid metallic conduit or cable system for surface mounting adjacent to or remote from equipment being controlled. • For individual motor control. • To prevent arcing internal to the enclosed switch from causing ignition of a specific hazardous atmosphere, or atmospheres. • In industrial areas such as chemical plants, oil and gas refineries, paint and varnish manufacturing plants, gasoline bulk loading terminals, and finishing areas where atmospheres may contain hazardous gases. • In non-hazardous areas where sturdy, durable enclosures are required. • When controlling motor, lighting and other circuits. • Enclosure – Krydon material • External Hardware – Stainless Steel • Operating Handle – Nylon Size Ranges: • Hub size: (2) 11/2" (30, 60 amps) (2) 21/2" (100 amps) Krydon material hubs included (not mounted) Ordering Information Furnished with Non-Fusible, Factory Sealed Motor Circuit Switch Features: Switch Ratings • Enclosed devices are unfused, factory sealed motor circuit switches. • Exceeds NEC® wiring end room requirements for ease of installation. • RSWP factory sealed industrial control switch, no external seals are required. • Enclosure is made of Krydon® highimpact strength fiberglass-reinforced polyester material having excellent corrosion resistance and stability to heat. • Krydon material hubs with integral bushings, for dead-end or through-feed arrangements are supplied. • Krydon material mounting feet supplied. • Suitable for wash down and corrosive areas (Type 4X). • A padlock can be used to lock the operating handle in the "OFF" position. • Rotary actuator with snap action. • Unitized, strong and durable construction provides longer service life for equipment. • Factory sealed 10A, 600 VAC auxiliary contact switch provided. Amperes 30 60 100 Maximum HP – 3 Phase Volts AC 240 480 600 Enclosure with 3-Pole Switch Hub Size Cat. # 10 15 20 11/2" 11/2" 21/2" 20 30 40 25 40 60 Dimensions In Inches: Certifications and Compliances: • NEC: Class I, Division 2, Groups B, C, D • NEMA: 3, 4X, 7 (B, C, D Div. 2), 12 • UL Standard: 508, 1604 • cUL to CSA Standard C22.2 No.213 • IP65 690 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business N2RS303 N2RS603 N2RS1003 GUSC Enclosures with General Use Snap Switches Applications: Size Ranges: GUSC snap switches are used: • In a rigid metallic conduit system for surface mounting adjacent to or remote from the equipment being controlled • To prevent arcing of the enclosed switches from causing ignition of a specific hazardous atmosphere, or atmospheres, external to the enclosure • In industrial areas such as chemical plants, oil and gas refineries, paint and varnish manufacturing plants, gasoline bulk loading terminals, grain elevators, grain processing industries, coal processing or handling areas, or metal handling or finishing areas where the atmosphere may contain hazardous gases and/or dust • In non-hazardous areas where sturdy, durable enclosures are required • Hub size – 3/4" (through feed arrangement) Features: 2A Electrical Rating Ranges: • See below Ordering Information: Rating Cat. # Style 250 (VAC) 600 (VAC) Horsepower Hub Size GUSC2052 AH 2-Pole 30A 20A 2 HP 3 GUSC2013 AH 3-Pole 30A 20A 2 HP 3 /4" /4" 2A • Enclosures are of rugged metal construction with mounting lugs and taper tapped hubs with integral bushings, in a through feed or bottom feed arrangement, for connection to the rigid metallic conduit • Cover is threaded, which provides for fast and proper assembly • Provided with a threaded operating shaft and bushing • Provision is made to use a padlock with 1 / 4" hasp, to lock the operating lever in an "ON" or "OFF" position • Body and cover threads treated with lubricant at factory to provide raintightness Explosionproof Dust-Ignitionproof Raintight Wet Locations Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 7CD, 9EFG, 12 Dimensions In Inches: Certifications and Compliances: • NEC/CEC: Class I, Div. 1 & 2, Groups C, D Class II, Div. 1, Groups E, F, G Class II, Div. 2, Groups F, G Class III • NEMA/EEMAC: 3, 7CD, 9EFG, 12 • UL Standard: 1203 • CSA Standard: C22.2, No. 30 Dimensions are approximate, not for construction purposes. Type Standard Materials: • • • • a b c d e f Through Feed Hubs – Fig. 1 2, 3-Pole Size 63/ 16 61/ 16 47/ 8 41/ 8 53/ 8 3 Two Hubs at Bottom – Fig. 2 2, 3-Pole 57/ 16 63/ 8 47/ 8 41/ 8 53/ 8 3 /8 g 21/ 4 Body – Feraloy® iron alloy Cover – copper-free aluminum Shaft – stainless steel Shaft bushing – stainless steel Standard Finishes: • Feraloy iron alloy – electrogalvanized and aluminum acrylic paint • Copper-free aluminum – natural • Stainless steel – natural www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 691 2A FSPC Enclosures Cl. I, Div. 1 & 2, Groups A†, B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 7A†BCD, 9EFG, 12 with General Use Snap Switches Applications: Standard Materials: FSPC snap switches are installed in a rigid metallic conduit system for surface mounting adjacent to or remote from equipment being controlled and are used: • To prevent arcing of enclosed switch from causing ignition of a specific hazardous atmosphere or atmospheres external to the enclosure • In industrial areas such as chemical plants, oil and gas refineries, paint and varnish manufacturing plants, gasoline bulk loading terminals, grain elevators, grain processing industries, coal processing or handling areas, or metal handling or finishing areas where atmosphere may contain hazardous gases and/or dust • In non-hazardous areas where sturdy, durable enclosures are required • • • • 2A Features: • Rugged cast metal enclosure with mounting lugs and taper tapped hubs with integral bushings, in a through feed arrangement. • Threaded cover to provide fast, proper assembly and easier maintenance. • Journalled type operating shaft – close tolerance fit for flametightness. • Body and cover threads treated with lubricant at factory to provide raintightness. Body – Feraloy® iron alloy Cover – copper-free aluminum Shaft – stainless steel Bushing – stainless steel Standard Finishes: • Feraloy iron alloy – electrogalvanized and aluminum acrylic paint • Copper-free aluminum – natural • Stainless steel – natural Ordering Information: Switch Information Hub Size Style Amperes 120VAC§ /4 3 /4 3 /4 3 /4 1-pole 2-pole 3-pole 3-way 20 20 ‡ 20 3 Enclosure with Switch 277VAC§ Cat. # Cat. # † 20 20 ‡ 20 FSPC21 FSPC22 FSPC230 FSPC23 FSPC216 FSPC226 FSPC2306 FSPC236 Dimensions In Inches: Certifications and Compliances: • NEC: FSPC 21 series – Class I, Divisions 1 & 2, Groups C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III • NEMA: 3, 7CD, 9EFG, 12 • NEC: FSPC 216 series – Class I, Divisions 1 & 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III • NEMA: 3, 7ABCD, 9EFG, 12 • UL Standard: 1203 • CEC: FSPC 216 series – Class I, Divisions 1 & 2, Groups C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III • Encl. 3, 5 • CSA Standard C22.2, No. 30 Dimensions are approximate, not for construction purposes. †Suitable for Groups A & B usage. ‡30A, 250 VAC; 20A, 600 VAC. §See pages 694–695 for AC-rated switch information. 692 www.crouse-hinds.com US: 1-866-764-5454 Explosionproof Dust-Ignitionproof Raintight Wet Locations CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business Cl. I, Zone 1 & 2 Ex de IIC T6 cCSAus Certified Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1 & 2 AEx de IIC T6 Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Light Switch 2A Applications: GHG273 series of switches are used: • To prevent arcing of enclosed switch from causing ignition of a specific hazardous atmosphere external to the enclosure • In Division 2, Zone 1 and Zone 2 industrial areas such as: chemical plants, oil and gas refineries, paint and varnish manufacturing plants, gasoline bulk loading terminals, grain elevators and processing industries, coal processing or handling areas, or finishing areas where atmosphere may contain hazardous gases and/or dust • In non-hazardous areas where sturdy, durable enclosures are required for both indoor and outdoor installations of light switches Ordering Information • • • • Cat. # • • • • Small and compact in design. Large grounding plate. Captive cover screws. Protective collar for inadvertent operation. Large actuator surface allows for operation while wearing work gloves. Labyrinth seal to guarantee the degree of protection IP66. The toggle has a luminescent label to locate switch in dark areas. Cable entry from the top is made possible by turning the base. Contact Arrangement Description Entry Size GHG 273 2000 L0005 GHG 273 2000 L0006 2-pole 2-pole 1 x 1/2" NPT 1 x 3/4" NPT GHG 273 6000 L0001 GHG 273 6000 L0002 3-way 3-way 1 x 1/2" NPT 1 x 3/4" NPT 2A Features: Dimensions In Inches: Certifications and Compliances: • • • • • • • • cCSAus Listed Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G Class II, Division 1, Groups F, G Class I, Zone 1 & 2, EEx de IIC T6 Class I, Zone 1 & 2, AEx de IIC T6 Class I, Zone 1 & 2, Ex de IIC T6 PTB Certificate of Conformity Ex-91.C.1017 • IP66 Standard Materials: • Body and cover – low temperature, impact-resistant thermoplastic • Shaft and screws – stainless steel • Grounding plate – brass Dimensions are approximate, not for construction purposes. Standard Finishes: • Thermoplastic – natural • Stainless steel – natural • Brass – nickel plate Electrical Ratings: Voltage Current 250VAC 16 Amps 50 / 60 Hz www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 693 Cl. I, Div. 1 & 2, Groups B*, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 7B*CD, 9EFG, 12 EDS and EFD Enclosures 2A with General Use Snap Switches Front Operated Applications: Options: EDS and EFD enclosures are installed in a rigid metallic conduit system for surface mounting adjacent to or remote from equipment being controlled and are used: • To prevent arcing of enclosed switch from causing ignition of a specific hazardous atmosphere or atmospheres external to the enclosure • In industrial areas such as chemical plants, oil and gas refineries, paint and varnish manufacturing plants, gasoline bulk loading terminals, grain elevators, grain processing industries, coal processing or handling areas, or metal handling or finishing areas where atmosphere may contain hazardous gases and/or dust • In non-hazardous areas where sturdy, durable enclosures are required Description • Two or three gang bodies can be supplied with combinations of devices listed for one gang enclosures – Refer to modular listing, section 4C 2A Features: • Small and compact in design. • Used with snap switches. • Mounting lugs and taper tapped hubs with integral bushings. • Large machine screws for fastening covers to bodies. • Lockout hole for padlock having 1/4" hasp is provided. • Threaded type shafts and bushings are used to insure flame tightness. GB • Bodies and Covers: copper-free aluminum ................ SA • Flush wall mounting cover with 1/2" overhang – single gang only – dull black instrument finish ...................... S173 EDS Enclosed Snap Switch Electrical Ratings Complies with U.L. snap switch test requirements as follows: Type of Test AC-Rated (only) Switch Overload Rated Amp. +380% Power Factor .40 – .50 100 cycles, 6 – 10 cycles per minute Non-Inductive Endurance 10,000 cycles, 18 – 24 cycles per minute at rated current – .98 min. P.F. Inductive Endurance 10,000 cycles, 18 – 24 cycles per minute – .75 – .80 P.F. Tungsten Filament Lamp 10,000 cycles, 6 – 10 cycles per minute at rated current and 120 volts Endurance Temperature Rise Not to exceed 30°C Dielectric Withstand 1500 volts Dimensions In Inches: • NEC/CEC: Class I, Divisions 1 & 2, Groups B*, C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III • NEMA/EEMAC: 3, 7B*CD, 9EFG, 12 • UL Standard: 1203 • CSA Standard: C22.2 No. 30 Standard Materials: Standard Finishes: • Feraloy iron alloy – electrogalvanized and aluminum acrylic paint • Stainless steel – natural Dimensions are approximate, not for construction purposes. Hub Size 3 /4 1 Dim. "h" /8 1 7 Dim. "I" /16 /16 13 15 *Class I, Group B: All units listed on this page can be modified for Class I, Group B usage. Add suffix GB to the catalog number. Example: EDS2129-GB. Seals must be installed within 11/ 2" of each conduit opening in Division 1. 694 www.crouse-hinds.com US: 1-866-764-5454 Suffix • Class I Group B, NEMA 7B – see listing pages .......... Certifications and Compliances: • Bodies and covers – Feraloy® iron alloy • Shafts – stainless steel • Shaft bushings – stainless steel Explosionproof Dust-Ignitionproof Raintight Wet Locations CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business EDS and EFD Enclosures Explosionproof Dust-Ignitionproof Raintight Wet Locations Cl. I, Div. 1 & 2, Groups B*, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 7B*CD, 9EFG, 12 with General Use Snap Switches Front Operated Dead end 2A Through feed Ordering Information: Amperes§ Single Gang Through Feed Cat. # Two Gang Style 120VAC 277VAC /4 /4 3 /4 3 /4 3 /4 1-pole 2-pole 3-pole 3-way 4-way 20 20 ‡✪ 20 20 20 20 ‡ 20 20 EDS2129 EDS218 EDS2123 EDS2130 EDS2140 EDSC2129† EDSC218† EDSC2123 EDSC2130 EDSC2140 Replacement Switch SW5 SW6 0206500 SW7 SW8 1 1 1 1 1-pole 2-pole 3-pole 3-way 20 20 ‡✪ 20 20 20 ‡ 20 EDS3129 EDS318 EDS3123 EDS3130 EDSC3129† EDSC318† EDSC3123 EDSC3130 SW5 SW6 0206500 SW7 EDS3229 EDS328 1 1 1 1 4-way 1-pole 2-pole 3-way 20 30 30 30 20 30 30 30 EDS3140 EFD3591 EFD3593 EFD3594 EDSC3140 EFDC3591† EFDC3593† EFDC3594 SW8 AH3991* AH3992* AH3993* EDS3240 EFD3691 3 3 ✪ ✪ ✪ ■ Dead End Cat. # Through Feed Cat. # EDS2229 EDSC2229† EDSC228† EDSC2223 EDSC2230 EDSC2240 EDS2230 EDS3230 EFD3694 2A Hub Size Dead End Cat. # EDSC3229† EDSC328† EDSC3223 EDSC3230 EDSC3240 EFDC3691† EFDC3693† EFDC3694 *Class I, Group B: All units listed on this page can be modified for Class I, Group B usage. Add suffix GB to the catalog number. Example: EDS2129-GB. Seals must be installed within 11/ 2" of each conduit opening in Division 1. †ON-OFF standard marking for 1-pole and 2-pole units ‡15A, 125 VAC; 10A, 250 VAC §See table on pages 694–695 for AC-rated switch information. ■Combinations of switches can be furnished. *Purchase from Eaton's Wiring Devices. ✪ Not factory sealed. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 695 2A WST Enclosed Switches NEMA 3R, 4, 12 Wet Locations Watertight Heavy Duty 30, 60, 100 Amp Applications: Options: WST heavy duty enclosed switches are used in conduit systems: • As a means of disconnecting motors, lighting and power circuits. A fusible type switch, when used, also provides for short circuit protection • Indoors or outdoors in industrial areas, subways, railroad facilities or any other area that is subjected to dust, dirt, chemical vapors or moisture (rain or hosing) • Either pole-mounted or on flat surfaces The following special options are available by adding suffix Cat. No.: Description Suffix • Auxiliary switch, 600VAC-DC heavy duty pushbutton station rating, can be supplied, and its contacts will close after switch contacts close and open before switch opens.................................. S483 2A Features: • Enclosure, handle and other exterior parts are lightweight and corrosion resistant. • Insulated – groundable type terminal block for grounded or ungrounded neutral supplied. • Mounting lugs may be rotated 90 degrees or moved to the vertical centerline position for pole-mounting. • Side hinged cover is retained in a closed position by compression spring drawpull catches, which permits the opening or closing of the cover without having to use any tools. Lower cover latch is equipped for padlocking. • The cover is interlocked with the body and operating mechanism to prevent the opening of the enclosure, except when the switch is in the "OFF" position. • The operating handle may be padlocked in the "ON" or "OFF" position, thereby preventing unauthorized operation of the switch and/or opening of the enclosure. Up to three padlocks may be used. • Switches are NEMA type HD heavy duty with visible blades, a quick make-andbreak mechanism with reinforced, positive pressure-type blade and jaw construction. Fusible types have fuse clips with steel reinforcing springs of positive pressure type. Pressure connectors are used for wire connection. Certifications and Compliances: • NEMA: 3R, 4, 12 • UL Standard: 98 • CSA Standard: C22.2 Nos. 4 & 14 Size Ranges: • Conduit openings for 1" – 11/ 2" inclusive are arranged for through feed. Removal of the threaded bushings permits use of the next larger conduit size. • Other sizes and arrangements are available. Detailed information on request. WST shown open Electrical Rating Ranges: • 2 and 3-pole; fusible or non-fusible; 240VAC, 600VAC and 250VDC • 30, 60 and 100 amperes • 3 to 75 hp Ordering Information: 240VAC 250VDC 600VAC 240VAC 600VAC/250VDC Cat. # 3 10 15 5 10 20 10 25 40 WST30254 WST60254 WST10254 3-Pole No Fuse 1 30 11/ 4 60 11/ 2 100 71/ 2 15 30 5 10 20 20 50 75 WST30354 WST60354 WST10354 2-Pole Fusible† 1 30 11/ 4 60 11/ 2 100 3 10 15 5 10 20 10 25 40 WST3025‡ WST6025‡ WST10025‡ 3-Pole Fusible† 1 30 11/ 4 60 11/ 2 100 71/ 2 15 30 5 10 20 20 50 75 WST3035‡ WST6035‡ WST10035‡ Conduit Amps Opening 2-Pole No Fuse 1 30 11/ 4 60 11/ 2 100 Standard HP Rating †Cartridge fuses are not included. ‡Arranged for NEC Class H fuses. May be field converted to NEC Class J fuses. Approximate Dimensions Dimensions Amps 30 60 100 In Inches: a b c d 69/16 69/16 99/16 201/16 201/16 265/16 113/4 123/4 147/8 71/4 71/4 81/4 Standard Materials: • Enclosure – copper-free aluminum • Operating handle – copper-free aluminum • Other exterior parts – stainless steel Standard Finishes: • Copper-free aluminum – natural • Stainless steel – natural 696 www.crouse-hinds.com US: 1-866-764-5454 Dimensions are approximate, not for construction purposes. CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 2A Cl. I, Div. 2, Groups B, C, D NEMA 3, 12 Raintight W2ST Enclosed Switches Heavy Duty 30, 60, 100 Amp Applications: Standard Materials: Dimensions W2ST Factory Sealed Industrial Control Switches are used: • In hazardous areas rated Class I, Division 2, Groups B, C and D • In a rigid metallic conduit or cable system • For surface or flush mounting adjacent to or remote from equipment being controlled • In industrial applications such as chemical plants, wastewater treatment plants, oil and gas refineries, steel mills or any other areas where atmospheres may contain hazardous gases • When controlling motors, pumps, valves, lighting and other circuits • Enclosure and operating handle – copper-free aluminum • Exterior hardware – stainless steel In Inches: Options: Description Suffix Auxiliary switch, factory sealed 10A, 600 VAC .................................... S483 Electrical Rating Ranges: • • • • 3-Pole Switch, No Fuse 30, 60 and 100 amperes 3 to 60 HP 600 VAC Ordering Information: Features: Amp Switch Cat. # 30 60 100 3-pole, No Fuse 3-pole, No Fuse 3-pole, No Fuse W2ST30354 W2ST60354 W2ST10354 a 69/16 b c d 201/16 113/4 71/4 2A • Enclosed devices are unfused, factory sealed motor circuit switches • Exceeds NEC® wiring end room requirements for ease of wiring • RSWP factory sealed industrial control switch, no external seals are required • The cover is interlocked with the body and operating mechanism to prevent the opening of the enclosure, except when the switch is in the "OFF" position • Mounting lugs may be rotated 90° or moved to the vertical centerline portion for pole mounting • Side hinged covers are retained in a closed position by compression spring draw-pull catches, which permit the opening or closing of the cover without tools • The switch operating handle may be padlocked in the "ON" or "OFF" position with up to three padlocks Horsepower Ratings: Single Phase W2ST 30A 60A 100A 3 Phase 120V 240V 480V 600V 120V 240V 480V 600V 3 3 5 7.5 7.5 10 20 20 25 25 25 30 7.5 7.5 10 15 15 20 30 30 40 40 40 60 Certifications and Compliances: • NEC/CEC: Class I, Division 2, Groups B, C and D • Type: 3 and 12 • UL Standard 698 • cUL to CSA Standard C22.2 No. 14 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 697 NEMA Type 3, 4X, 12 Corrosion Resistant Watertight Industrial Disconnect Switches 2A 30, 40, 60, and 100 Amp 600VAC Non-metallic Enclosure Applications: Standard Materials: • Used in manual "ON" and "OFF" control of single-phase or three-phase AC motors where overload protection is not required or is provided separately. • Meet NEC Article 430 requirements for a separate disconnect means within sight of all motor loads. • Offers the ability to lock directly wired motor loads in the "OFF" position to comply with OSHA lockout/tagout requirements. • Meets stringent hosedown requirements. • • • • • • Enclosure – VALOX® thermoplastic Enclosure Gasket – Neoprene Handle – Impact-resistant Thermoplastic Cover Screws – Stainless Steel Screw Assembly Inserts – Brass Conduit Entries – See Table 1* 2A Features: • Enclosures are constructed from high impact thermoplastic, providing superior durability and corrosion resistance. • Enclosure designed with tapered edges to keep liquids away from cover opening. • Large pistol-grip handle provides easy gripping even with gloved hands. • Lockable handle meets OSHA lockout/ tagout requirements. Handles can be locked in the "OFF" position. • Hidden hinge cover opens to 145°, making installation and maintenance quick and easy. • Formed-in-place continuous gasket ensures NEMA 4X full perimeter sealing. • Captive cover mounting screws. • Brass enclosure assembly cover screw inserts allow for higher torque and prevent stripping. Certifications and Compliances: All units • cUL • NEMA Type 3, 4X, 12 Non-fused Units • UL 508 – 40 & 60 amp • UL 98 – 100 amp Fused Units • UL 98 – Enclosed Switch Ordering Information Cat. # Description NRS30 40A, 600V, no auxiliary contacts NRS30AX 40A, 600V, with auxiliary contacts NRS30 FS 30A, 600V, with fusible switch for short circuit protection NRS30AX FS 30A, 600V, with auxiliary contacts and fusible switch for short circuit protection NRS60 60A, 600V, no auxiliary contacts NRS60AX 60A, 600V, with auxiliary contacts NRS60FS 60A, 600V, with fusible switch for short circuit protection NRS60AX FS 60A, 600V, with auxiliary contacts and fusible switch for short circuit protection NRS100 100A, 600V, no auxiliary contacts NRS100AX 100A, 600V, with auxiliary contacts NRS100 FS 100A, 600V, with fusible switch for short circuit protection NRS100AX FS 100A, 600V, with auxiliary contacts and fusible switch for short circuit protection NRS K1 40A - 100A nonfused auxiliary contact kit NRS K2 60A - 100A fused auxiliary contact kit NRS K3 30A fused auxiliary contact kit Options: • Auxiliary contacts for use with pilot light of PLC. 10A 600VAC 1 NO. & 1 N.C. Consult Factory. *Hubs must be ordered separately. See Table 1. VALOX® is a registered trademark of General Electric Co. 698 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business Industrial Disconnect Switches 2A NEMA Type 3, 4X, 12 Corrosion Resistant Watertight 30, 40, 60, and 100 Amp 600VAC Non-metallic Enclosure Electrical Rating Ranges: Horsepower Ratings: Single Phase Three Phase Switches 120V 240V 208V 240V 480V 600V 40A Nonfused 60A Nonfused 100A Nonfused 30A Fused 60A Fused 100A Fused 1 2 5 2 – – 5 7.5 15 3 – – 10 15 25 7.5 15 25 10 15 30 7.5 15 30 20 30 50 15 30 60 25 30 50 20 50 75 Dimensions In Inches: Enclosure Type 40 Amp Nonfused 60 Amp Nonfused 100 Amp Nonfused 30 Amp Fused 60 Amp Fused 100 Amp Fused A B C D E F 6.0 8.0 10.0 10.0 14.0 14.0 6.0 6.0 8.0 8.0 12.0 12.0 5.9 5.9 7.9 7.9 7.9 7.9 8.1 8.1 10.1 10.1 10.1 10.1 6.75 8.75 10.75 10.75 14.75 14.75 4.0 4.0 6.0 6.0 8.0 8.0 2A Table 1 - Conduit Entries Ordering Information Krydon® Cat. # Size Myers™ Zinc Cat. # Size Myers™ Stainless Steel Cat. # NHUB1 NHUB2 NHUB3 NHUB4 NHUB5 /2" 3 /4" 1" 11/4" 11/2" STG STG STG STG STG /2" 3 /4" 1" 11/4" 11/2" SSTG SSTG SSTG SSTG SSTG 1 1 2 3 4 5 www.crouse-hinds.com 1 US: 1-866-764-5454 CAN: 1-800-265-0502 1 2 3 4 5 Size /2" /4" 1" 11/4" 11/2" 1 3 Copyright© 2013 Eaton’s Crouse-Hinds Business 699 2A NEMA 3R Manual Contactors AC Only, Full Voltage 30A/40A/60A 600VAC Without Overload Protection Applications: Manual Contactors are used: • For manual starting of motors up to 30 HP • In damp or wet locations Features: • Compact enclosure meets NEMA 3R requirements • Can be padlocked to help conform to OSHA lockout requirements • Grounding terminal provides ground for box and cover • Enclosed switch body does not expose contacts • Double break butt-type silver alloy contacts provide long life • Two 1/2", 3/4", 1" knockouts on bottom 2A Certifications and Compliances: Ordering Information: Description Amps 600V Horsepower 480/ 120V 240V 600V Switch Cat. # Switch & Enclosure Cat. # 2 pole with screw terminals 30 2 5 7.5 6810U 6810W 3 pole with screw terminals 30 3 7.5 15 7810UD 7810WD 2 pole with screw & clamp terminals 40 3 5 15 MC240C MC240C-3 2 pole with box lug terminals 40 3 5 15 MC240L MC240L-3 2 pole with box lug terminals 60 3 5 15 MC260L MC260L-3 3 pole with screw & clamp terminals 40 3 7.5 15 / 20 MC340C MC340C-3 Standard Materials: 3 pole with box lug terminals 40 3 7.5 15 / 20 MC340L MC340L-3 • .060" thick steel enclosure 3 pole with box lug terminals 60 3 7.5 25 / 30 MC360L MC360L-3 • UL 508 • CSA Standard: C22.2 No. 14 • NEMA 3R Dimensions Standard Finishes: In Inches: 6810 / 7810 Series: • Gray baked enamel finish MC Series: • Polyester urethane Electrical Rating Ranges: • 30A/40A/60A 600VAC, two pole, single phase • 30A/40A/60A 600VAC, three pole, polyphase 700 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business NST Disconnect Switches and Enclosures 600VAC/250VDC Heavy Duty Applications: Options: • NST disconnect switches are for use in disconnecting motor, lighting and other circuits. Description Suffix • Auxiliary switch, 600 VAC-DC heavy duty pushbutton station rating, can be supplied. Its contacts will close after switch contacts close and open before switch opens................................ S483* • Hubs (see "Note on Hubs") – see page 677 • Grounding plate or bushing – see page 677 Features: • Enclosures are made of Krydon®, Eaton's Crouse-Hinds' high impact strength fiberglass-reinforced polyester material having excellent corrosion resistance and stability to heat. • Unitized, strong and durable enclosure construction provides longer service life for equipment. • Enclosure has hinged access door which opens 160° for easy wiring and maintenance. Three screws for door frame are hidden behind access door. • Access door may be padlocked to prevent unauthorized access. 2A Corrosion-Resistant Dust-tight Watertight Weatherproof NEMA 3, 4X, 12 2A Certifications and Compliances: Disconnect switch with built-in Krydon material handle • NEMA: 3, 4X and 12 • UL Standard: 98 • CSA Standard: C22.2 No. 4 Electrical Rating Ranges: • 240 VAC/250 VDC & 600 VAC • 30, 60, 100 and 200 amp Ordering Information: To order an enclosure complete with disconnect switch, insert the manufacturer’s symbol in the designated positions of the catalog number. Symbols are shown in the footnotes. Enclosures only can be ordered. Select from the listings below. Max HP Rating Enclosure DC using 2 poles only AC Polyphase 250V Max. With Switch 240VAC/250VDC Cat. # With Switch 600VAC Cat. # Without Switch Cat. # 20 40 50 100 5 10 20 40 NST1018F ➀30320 NST1018F ➀60320 NST1426F ➀10320 NST1426F2 ➀20320† NST1018F ➀30360 NST1018F ➀60360 NST1426F ➀10360 NST1426F2 ➀20360† NST1018F ➀ NST1018F ➀ NST1426F ➀ NST1426F2 ➀† 20 40 50 100 5 10 20 40 NST1018F ➀30321 NST1018F ➀60321 NST1426F ➀10321 NST1426F2 ➀20321† NST1018F ➀30361 NST1018F ➀60361 NST1426F ➀10361 NST1426F2 ➀20361† NST1018F ➀ NST1018F ➀ NST1426F ➀ NST1426F2 ➀† Amp Rating 200/240V Non-Fusible 30 71/2 60 15 100 30 200 50 440/480V 550/600V 15 30 50 125 Fusible‡ 30 60 100 200 15 30 50 125 71/2 15 30 50 ➀ Disconnect Switches: Manufacturer General Electric Square D Cutler-Hammer Symbol Switch Type G D W Type QMW Class 9422 Type DS NOTE ON HUBS: The following number and sizes of hubs (not mounted) are included when disconnect switches are ordered complete. If enclosures only are ordered, hubs must be ordered separately (see "Options"). Switch Size 30 60 100 200 Number Included Hub Size 2 2 2 2 3 /4 11/4 2 21/2 *For Square D switches only. †For General Electric switches only. Accommodates Class J fuses only. Not available with Cutler-Hammer "W" switch. ‡Fuse clips are arranged for Class H fuses and field modifiable for Class J fuses. For Class R fuses, consult Eaton's Crouse-Hinds. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 701 NST Disconnect Switches and Enclosures 2A Corrosion-Resistant Dust-tight Watertight Weatherproof NEMA 3, 4X, 12 600VAC/250VDC Heavy Duty Dimensions* In Inches: 2A NMC, NCB & NST Cat. # Outside Dimensions l w d Mounting Dimensions mw ml Door Opening Dimensions dl dw NST1018 NST1426 1913/32 2713/32 823/32 923/32 77/8 117/8 167/8 2311/16 1113/32 1513/32 193/8 271/4 *Dimensions are approximate, not to be used for construction purposes. 702 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 511/16 911/16 3A Instruments Hazardous Description Page No. Clocks TCH see page 711 Telephones ETW Ex-ResistTel, FernTel IP see page 712 see page 713 Thermostats HRC see page 709 Heaters EXH XC see pages 704–705 see pages 707–708 3A www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 703 3A EXH Series Explosionproof Electric Air Heaters Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G NEMA 7CD, 9EFG Explosionproof Dust-Ignitionproof Applications: EXH explosionproof electric heaters are used: • In areas made hazardous by the presence of flammable gases and vapors, and combustible dusts • For rugged locations including: oil refineries, petrochemical plants, rigs, pumping stations, turbine compressors, pulp and paper mills, coal mines, grain elevators, etc. • In areas where flammable vapors or gases or highly combustible dusts may be present due to accidental or abnormal conditions • For standby heat to prevent process heat loss, or for personnel comfort during maintenance/repair operations 3A Features: • Split fan guard for easy access to fan • Compact design makes handling during installation easy • Evacuated cores heat up quickly with even heat distribution • Larger models offer greater kilowatt range providing more economical means to heat large areas • Permanently sealed cores improve reliability and make field servicing easier • Control box provides easy access for installation and maintenance Certifications and Compliances: • • • • • • Class I, Division 1 & 2, Groups C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G NEMA: 7CD, 9EFG UL Standard: 823 CSA Standard: C22.2 Nos. 25, 30, 46 Heater shown has optional built-in thermostat. Options: The following special options are available: Description Suffix Built-in disconnect switch ................................................................................................ D Built-in pilot light .............................................................................................................. P 3-way switch .................................................................................................................... S Built-in thermostat ............................................................................................................ T Built-in HRC1 explosionproof thermostat ........................................................................ HRC Accessories: • Basic mounting kit – suitable for applications where the support arm can be bolted or welded directly to structural steel or concrete. Cat. # BMK-EXH5 (insert fan size: 12, 16 or 20) • Wall mounting kit – suitable for mounting on Z sections. Cat. # WMK-EXH5 (insert fan size: 12, 16 or 20) • Hanging mounting kit – simple and economical if adequate overhead structure exists. Requires 1/ 2" pipe, cut and threaded — not supplied. Cat. # HMK-EXH5 • Swivel hanging mount kit – swivels 360°. Requires 1/2" pipe, cut and threaded – not supplied. Cat. # SHMK-EXH5 (insert fan size: 12, 16 or 20) • Pipe mounting kit – useful in buildings with insufficient strength to use other types of mounts. requires 3" pipe. Cat. # PMKEXH5 (insert fan size: 12, 16 or 20) Standard Materials and Finishes: • Fan – Aluminum blade; steel spider and hub with 5/8 in. (15.875 mm.) bore • Core – Steel with integral aluminum fins, vacuum charged and hermetically sealed • Heating Elements – Three long life, low watt-density, high grade metal sheathed elements • Heat Transfer Fluid – Long life formulated ethylene glycol and water, freeze protected to –49°F (–45°C) • Cabinet Material – 14 gauge (0.075 in.) (1.90 mm) steel; epoxy coated with 5 stage pre-treatment including iron phosphate • Conduit Material – Heavy walled, 0.122 in (3.1 mm.) steel cadmium plated BMK Basic Mounting Kit SHMK Swivel Hanging Mounting Kit WMK Wall Mounting Kit 704 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business HMK Hanging Mounting Kit PMK Pipe Mounting Kit 3A Cl. I, Div. 1 & 2, Groups C, D Explosionproof Dust-Ignitionproof Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G NEMA 7CD, 9EFG EXH Series Explosionproof Electric Air Heaters Specifications: EXH512 EXH516 EXH520 3 5 7.5 10 15 20 25 30 35 Maximum Altitude Nominal kW (ft.) (m.) 12,000 3,658 8,000 2,438 10,000 3,048 7,000 2,134 10,000 3,048 7,000 2,134 10,000 3,048 7,000 2,134 6,000 1,829 Air Delivery @70°F @ 21°C (CFM) (m3/hr) 500 850 500 850 850 1444 850 1444 1750 2973 1750 2973 3600 6116 3600 6116 3,950 6,711 Horizontal Throw (ft.) (m.) 15 4.6 15 4.6 30 9.1 30 9.1 40 12.2 40 12.2 70 21.3 70 21.3 70 21.3 Max. Mounting Height (ft.) (m.) 7 2.1 7 2.1 10 3.0 10 3.0 10 3.0 10 3.0 20 6.1 20 6.1 20 6.1 Motor Power (HP) (kW) 1 /2 0.187 1 /2 0.187 1 /2 0.187 1 /2 0.187 1 /2 0.187 1 /2 0.187 1 /2 0.373 1 /2 0.373 1 Fan Diameter (in.) (mm.) 12 305 12 305 12 305 12 305 16 406 16 406 20 508 20 508 20 508 Net Weight (lbs.) (kg.) 140 63.5 140 63.5 140 63.5 140 63.5 168 76.2 168 76.2 201 91.2 201 91.2 201 91.2 Shipping Weight (lbs.) (kg.) 194 88 194 88 194 88 194 88 218 98.9 218 98.9 252 114.3 252 114.3 252 114.3 Motor Type Explosionproof. Thermally protected. Permanently lubricated ball bearings. 1725 RPM. Fan Guard Split design with close wiring spacing. 1/4 in. (6.3mm.) probe will not enter. Heating Elements Three long-life, low watt-density, high grade metal-sheathed elements. Temperature High-Limit Automatic reset type, snap-action bimetal, open on temperature rise. Rated 100,000 cycles at 10 amps, handles 0.128 amps. Control Circuit 120 Volts, 0.128 ams, 15 VA. Control Transformer Multi-tap primary, 120V secondary, 50 VA. Contactor 60 or 100 amp. rated 1,000,000 cycles at maximum capacity, operating at not more than 84% full load. 120V, 15 VA fuse protected coil. Overpressure Protection Fusible alloy plug 170 psi (1.17 MPa). Temperature Code Rating T3B 165°C (329°F) Class I & II. Temperature Limitations Operational; –49°F to 176°F (–45°C to 80°C), short term to 248°F (120°C). /2 0.373 3A Dimensions In Inches: 2.5 - 12.5 - 20.9 - Dim. Dimension 10 kW 20 kW 35 kW Tolerance ± A in. mm 87/16 215 87/16 215 87/16 215 1 /8 3 B in. mm 183/16 462 225/16 566 261/4 667 1 /8 3 C in. mm 27 686 31 787 35 889 3 /16 4 D in. mm 181/2 470 221/2 572 261/2 674 1 /8 3 E in. mm 197/15 494 237/16 596 277/16 697 3 /8 10 F in. mm 171/2 444 191/2 495 2113/16 554 5 /16 8 Dimensional tolerances ±1/8" (3.2mm) unless otherwise specified. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 705 Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G NEMA 7CD, 9EFG EXH Series Explosionproof Electric Air Heaters 3A Explosionproof Dust-Ignitionproof Ordering Information: Voltage Phase Cat. # Maximum Total Current (Amperes) Temperature Rise °F °C Heat Output BTU/Hr. EXH512 3.0 3.0 3.0 3.0 3.0 3.0 3.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 7.5 7.5 7.5 7.5 7.5 7.5 7.5 10.0 10.0 10.0 10.0 10.0 10.0 208 208 240 240 480 480 600 208 208 240 240 480 480 600 208 208 240 240 480 480 600 208 240 240 480 480 600 1 3 1 3 1 3 3 1 3 1 3 1 3 3 1 3 1 3 1 3 3 3 1 3 1 3 3 EXH5-208160-030 EXH5-208360-030 EXH5-240160-030 EXH5-240360-030 EXH5-480160-030 EXH5-480360-030 EXH5-600360-030 EXH5-208160-050 EXH5-208360-050 EXH5-240160-050 EXH5-240360-050 EXH5-480160-050 EXH5-480360-050 EXH5-600360-050 EXH5-208160-075 EXH5-208360-075 EXH5-240160-075 EXH5-240360-075 EXH5-480160-075 EXH5-480360-075 EXH5-600360-075 EXH5-208360-100 EXH5-240160-100* EXH5-240360-100 EXH5-480160-100 EXH5-480360-100 EXH5-600360-100 14.4 8.3 12.5 7.2 6.3 3.6 2.9 24.0 13.9 20.8 12.0 10.4 6.0 4.8 36.1 20.8 31.3 18.0 15.6 9.0 7.2 27.8 41.7 24.1 20.8 12.0 9.6 11.2 11.2 11.2 11.2 11.2 11.2 11.2 18.6 18.6 18.6 18.6 18.6 18.6 18.6 27.9 27.9 27.9 27.9 27.9 27.9 27.9 37.2 37.2 37.2 37.2 37.2 37.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 10.3 10.3 10.3 10.3 10.3 10.3 10.3 15.5 15.5 15.5 15.5 15.5 15.5 15.5 20.7 20.7 20.7 20.7 20.7 20.7 10,250 10,250 10,250 10,250 10,250 10,250 10,250 17,100 17,100 17,100 17,100 17,100 17,100 17,100 26,600 26,600 26,600 26,600 26,600 26,600 26,600 34,150 34,150 34,150 34,150 34,150 34,150 EXH516 15.0 15.0 15.0 15.0 20.0 20.0 20.0 240 480 480 600 480 480 600 3 1 3 3 1 3 3 EXH5-240360-150 EXH5-480160-150 EXH5-480360-150 EXH5-600360-150 EXH5-480160-200 EXH5-480360-200 EXH5-600360-200 36.1 31.3 18.0 14.4 41.7 24.1 19.2 27.1 27.1 27.1 27.1 36.1 36.1 36.1 15.1 15.1 15.1 15.1 20.1 20.1 20.1 51,200 51,200 51,200 51,200 68,300 68,300 68,300 EXH520 25.0 25.0 30.0 30.0 35.0 35.0 480 600 480 600 480 600 3 3 3 3 3 3 EXH5-480360-250 EXH5-600360-250 EXH5-480360-300 EXH5-600360-300 EXH5-480360-350 EXH5-600360-350 30.1 24.1 36.1 28.9 42.1 33.7 45.2 45.2 26.4 26.4 30.7 30.7 25.1 25.1 14.6 14.6 17.1 17.1 85,400 85,400 102,360 102,360 119,450 119,450 3A Nominal Wattage (kW) Catalog Number Example: * Not available with built-in disconnect switch (option D). 706 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business NEC: Cl. I, Div. 1 & 2, Groups B*, C & D IEC: Cl. I, Zones 1 & 2, Group IIB & H2* NEMA: 7B*CD XC Series Explosionproof Electric Heaters 3A Applications: Standard Features: • Sloped-top cabinet prevents objects that restrict airflow from being set on top • Corrosion-resistant design with no exposed copper or brass – suitable for H2S environments • High-velocity airflow heats up area faster with better heat distribution • 14-gauge steel cabinet for rugged reliability • Short cabinet lengths take up less wall and floor space • Optional built-in thermostat (Class I, Division 1, Groups C & D, and Zone 1, Group IIB models) reduces field installation costs • Incoloy® 840 heating elements have longer life expectancy • Radial-embossed aluminum plate fins warp less for better heat transfer • Galvanized steel mounting brackets for quick installation Certifications and Compliances: • NEC: Class I, Divisions 1 & 2, Groups B*, C, D • IEC: Class I, Zones 1 & 2, Group IIB + H2* • NEMA: 7B*CD • UL Standard: 823 • CSA Standard: C22.2 Nos. 25, 30, 46 • Temperature Code: T2A – 280°C (536°F) 3A Single phase XC explosionproof electric heaters are used: • In areas where flammable liquids, gases or vapors are present • For rugged locations including: – Petroleum refineries, gasoline storage and dispensing areas – Wastewater treatment plants – Areas that use flammable liquids for cleaning parts in dip tanks – Petrochemical plants – Paint spraying areas – Aircraft hangars and fuel servicing areas – Hydrogen fuel cell and battery storage facilities – Natural gas plants • In areas where flammable vapors or gases may be present due to accidental or abnormal conditions • For standby heat to prevent process heat loss or for personnel comfort during maintenance/repair operations Standard Materials and Finishes: • Heating elements – resistance wire embedded in a magnesium oxide refractory and sheathed in an Incoloy® 840 tube • Finned tube assembly – aluminum tube with radial-embossed aluminum plate fins • Cabinet – 14-gauge (0.075"/1.90 mm) steel, green-gray epoxy powder-coated front and side panels, galvanized steel back panel Accessories and Options: • Built-in thermostat for 120-, 208-, 240-, 277- or 480-volt applications (see ordering information on next page) • Remotely mounted HRC85 explosionproof thermostat using Honeywell® control for 45°F– 85°F heating range (order separately) Specifications: Nominal kW Shipping Weight (lbs.) (kg) Enclosures 1.2 1.8 3.6 4.8 7.6 61.3 27.8 61.3 61.3 88.4 104.3 27.8 27.8 40.1 47.3 NEMA Type 7. For dry indoor use only. Do not immerse in water. Do not store or use in areas exposed to rain or snow. Mounting Brackets Two 14-gauge galvanized steel brackets. Heating Elements Two Incoloy® 840-sheathed elements. Optional Built-In Thermostat Explosionproof room thermostat with 10 settings. Cabinet Material 14-gauge (0.075"/1.90 mm) steel. Rear panel is galvanized. Front and side panels are baked green-gray epoxy powder coated with five-stage pre-treatment, including iron phosphate. Temperature Code Rating T2A – 280°C (536°F) Temperature Limitations Operational –45°C to 40°C (–49°F to 104°F) Storage –45°C to 80°C (–49°F to 176°F) *Hydrogen applications only apply to heaters without built-in thermostats. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 707 3A XC Series Explosionproof Electric Heaters NEC: Cl. I, Div. 1 & 2, Groups B*, C & D IEC: Cl. I, Zones 1 & 2, Group IIB & H2* NEMA: 7B*CD Ordering Information: With built-in room thermostat – Class I, Div. 1 & 2, Groups C & D; Zones 1 & 2, Group IIB Without built-in room thermostat – Class I, Div. 1 & 2, Groups B, C & D; Zones 1 & 2, Group IIB + H2 3A Cat. # Unit Wattage (kW) Unit Unit Output Voltage (BTU/Hr) (Volts) Unit Current (Amps) Maximum Circuit Fuse (Amps)* XC XC XC XC XC XC A1 A2 A3 A4 A5 A6 N0 N0 N0 N0 N0 N0 1.2 1.2 1.2 1.2 1.2 1.2 4097 4097 4097 4097 4097 4097 120 208 240 480 600 277 10.0 5.8 5.0 2.5 2.0 4.3 15 15 15 15 15 15 XC XC XC XC XC XC B1 B2 B3 B4 B5 B6 N0 N0 N0 N0 N0 N0 1.8 1.8 1.8 1.8 1.8 1.8 6146 6146 6146 6146 6146 6146 120 208 240 480 600 277 15.0 8.7 7.5 3.8 3.0 6.5 20 15 15 15 15 15 XC XC XC XC XC C2 C3 C4 C5 C6 N0 N0 N0 N0 N0 3.6 3.6 3.6 3.6 3.6 12292 12292 12292 12292 12292 208 240 480 600 277 17.3 15.0 7.5 6.0 13.0 20 20 15 15 15 XC XC XC XC XC D2 D3 D4 D5 D6 N0 N0 N0 N0 N0 4.8 4.8 4.8 4.8 4.8 16389 16389 16389 16389 16389 208 240 480 600 277 23.1 20.0 10.0 8.0 17.3 25 25 15 15 20 XC XC XC XC XC E2 E3 E4 E5 E6 N0 N0 N0 N0 N0 7.6 7.6 7.6 7.6 7.6 25950 25950 25950 25950 25950 208 240 480 600 277 36.5 31.7 15.8 12.7 27.4 40 35 20 15 30 Cat. # Unit Unit Unit Unit Wattage Output Voltage Current (kW) (BTU/Hr) (Volts) (Amps) Maximum Circuit Fuse (Amps)* XC XC XC XC XC A1 A2 A3 A4 A6 B1 B2 B3 B4 B6 1.2 1.2 1.2 1.2 1.2 4097 4097 4097 4097 4097 120 208 240 480 277 10.0 5.8 5.0 2.5 4.3 15 15 15 15 15 XC XC XC XC XC B1 B2 B3 B4 B6 B1 B2 B3 B4 B6 1.8 1.8 1.8 1.8 1.8 6146 6146 6146 6146 6146 120 208 240 480 277 15.0 8.7 7.5 3.8 6.5 20 15 15 15 15 XC XC XC XC C2 C3 C4 C6 B2 B3 B4 B6 3.6 3.6 3.6 3.6 12292 12292 12292 12292 208 240 480 277 17.3 15.0 7.5 13.0 20 20 15 15 XC D3 B3 4.8 XC D4 B4 4.8 XC D6 B6 4.8 16389 16389 16389 240 480 277 20.0 10.0 17.3 25 15 20 XC E4 B4 7.6 25950 480 15.8 20 *Or equivalent breaker as per National Electrical Code and Canadian Electrical Code 1. Remote-mounted explosionproof room thermostats are not suitable for Group B & IIC applications. Remote contactors are also required on all 600-volt heaters and heaters with a current draw greater than 22 amps (supplied and installed by others). 2. Remote mounted explosionproof room thermostats suitable for Group B, IIB + H2 applications are a special-order item. 3. Operation at lower than rated voltages will result in reduced kW output and amp draw. Actual Output (kW) = [(Supply Voltage)2 ÷ (Rated Voltage)2] x Rated Unit Wattage (kW) Dimensions In Inches: Heater kW Rating 1.2 - 3.6 4.8 7.6 A Dimensions B Dimensions 37.0" (940mm) 55.125" (1400mm) 65.125" (1654mm) 31.34" (796mm) 49.45" (1256mm) 59.49" (1511mm) *Hydrogen applications only apply to heaters without built-in thermostats. 708 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business HRC Thermostats with Honeywell Control Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 7CD, 9EFG, 12 Explosionproof Dust-Ignitionproof Raintight Wet Locations 3A Applications: HRC thermostats with Honeywell control are used: • For heavy duty line voltage thermostats to control fan coils, fans, motor starters, valves, contactors, and circulator motors in heating and/or cooling systems. If larger motors than listed are to be controlled, relays or magnetic motor starters must be interconnected between motors and thermostats • In specific hazardous atmospheres such as encountered in oil refineries, chemical plants, paint and varnish manufacturing plants, certain hazardous metal finishing areas, coal processing locations, granaries and grain processing plants Features: Electrical Rating Ranges: • 120 / 240 VAC • 50 / 60 hertz • Full load current in amperes: Heating Cooling 3A • A heavy duty snap switch is mounted in the enclosure; the temperature sensitive element is mounted on the external surface of the cover and actuates the switch through a shaft and bearing mechanism • An external knob permits temperature setting within calibrated range; the knob is removable to prevent unauthorized adjustment; room ambient is indicated on thermometer at front 120 VAC 240 VAC 10.2 7.4 6.5 4.0 Ordering Information: Certifications and Compliances: • NEC/CEC: Class I, Division 1 & 2, Groups C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III • NEMA/EEMAC: 7CD, 9EFG, 12 • UL Standard: 1203 • CSA Standard: C22.2 No. 30 Temperature Range Non-Adjustable Operating Differential (approx.) Cat. #† 45 – 85°F 1° F HRC85 †Furnished with thermostat and thermometer. Dimensions* In Inches: Standard Materials: • Feraloy® iron alloy Standard Finishes: • Electrogalvanzed and aluminum acrylic paint Size Ranges: • Hubs – 3/4" through-feed *Dimensions are approximate, not for construction purposes. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 709 HRC Bimetal Thermostat 3A Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III Explosionproof Dust-Ignitionproof Applications: HRC Bimetal Thermostats are used: • To control heating only, cooling only or ventilation systems in demanding industrial environments • In specific hazardous atmospheres such as encountered in oil refineries, chemical plants, paint and varnish manufacturing plants, coal processing locations, waste storage facilities, pulp and paper mills, granaries and grain processing plants or any other location where specific explosive gases or dusts are present 3A Features: • Bimetal sensing element that is fast acting, reliable and unaffected by altitude • Compact, lightweight design makes it easy to install • No exposed copper or brass parts for excellent resistance to corrosion • Feed-through design for easy installation • Durable all aluminum exterior • Available for heating only or heating or cooling/ventilation applications Certifications and Compliances: Ordering Information Hub Size Description Cat. # /4 3 /4 Single Pole, Single Throw (heating only) Single Pole, Double Throw (heating or cooling/ventilation applications) HRC1 HRC2 3 Dimensions In Inches: • NEC/CEC: Class I, Division 1 & 2, Groups C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III • UL Standard: 1203 • CSA Standard: C22.2 No. 30 Standard Materials: • Copper-free aluminum Standard Finishes: • Natural Size Ranges: • Conduit opening – 3/4" hub Electrical Ratings: • • • • 480 VAC max / 2 HP @ 120 VAC 1 HP @ 250 VAC 22 amps Res. 1 Temperature Range: • 36°F to 82°F (2°C to 28°C) • Temperature differential: 2.5°F (1.5°C) 710 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business TCH Electric Clocks Explosionproof Dust-Ignitionproof Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III Factory-sealed 3A Applications: Type TCH electric clocks are used: • In oil refinery control rooms, hospital operating rooms, chemical plants, grain handling and processing plants and other similar locations where specific hazardous atmospheres may exist Features: • Sheet steel case may be used where environmental conditions are not severe; electric motor and connections are contained in corrosion-resistant enclosure; dials are 13" in diameter; reset knob protrudes from bottom of case • Disassembly for installation and maintenance is easily performed; the motor housing is factory-sealed, with no external seals required Sheet Steel Case Certifications and Compliances: Standard Materials: • Clock body and cover – sheet steel • Motor housing – copper-free aluminum Enclosure with Clock Motor Hub Size 110 VAC 60 hertz Self-Starting Synchronous (3 Watts) 1" Style Cat. # Enclosing Sheet Metal Band Cat. # With Sheet Steel Case Surface Mount TCH2220 TCH202 3A Ordering Information: • NEC: Class I, Division 1 & 2, Groups C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III • UL Standard: 1203 Dimensions* In Inches: Standard Finishes: • Aluminum – aluminum acrylic paint • Sheet steel – baked aluminum enamel Size Ranges: • Hubs – 1" through-feed Electrical Rating Ranges: • 110VAC, 60 hertz • Self-starting synchronous motor – 3 watts Options: The following special options are available: Description Suffix Sheet metal band notched for conduit, can be supplied for enclosing gap between wall surface See and back of case listings *Dimensions are approximate, not for construction purposes. Cat. # a b c TCH2220 17 27/8 37/16 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 711 3A ETW Telephones Cl. I, Div. 1 & 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications: ETW series telephones are used: • For communication in areas which may be hazardous due to the presence of flammable gases or vapors, and/or combustible dusts • In chemical plants, oil refineries, bulk loading stations, paint and varnish manufacturing plants, grain processing and similar industries 3A Features: • Modern styled, pushbutton wall-mount unit is very rugged in design, suitable for the harshest industrial applications • Large, easy to read keyboard allows gloves-on operation • Cast copper-free aluminum housing, with baked on powder coat finish, is highly resistant to corrosive atmospheres • Units are tone or pulse compatible and offer superior audio clarity • Handset cord features a pin-type connector for easy field replacement; handset circuit is intrinsically safe • Up to ten units can be connected on one line ETW401 Certifications and Compliances: Ordering Information: • NEC/CEC: Class I, Divisions 1 & 2, Groups B, C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G • UL Standard: 1203, 698 • CSA Standard: C22.2 No. 30 • FCC Approved Description Cat. # Phone w/ handset Replacement handset (10' cord) ETW Replacement handset (20' cord) ETW Phone w/ headset Phone push-to-talk handset Replacement headset Explosionproof ringer ETW401 ETW:301SC ETW:301SC 20 ETW401 HS ETW401 PB ETW:P7200 ETR1 Standard Materials: Dimensions • Enclosure – copper-free aluminum • Handset – high impact plastic In Inches: Standard Finishes: • Enclosure – baked powder paint (safety blue) Accessories: • A standard volume explosionproof ringer (ETR1) is available, see page 714 for listing. • For locations with a high level of ambient noise, a louder ringer can be installed. An ESR bell or ETH horn may be used by installing an ETC relay between the telephone line switch and the bell or horn. The relay coil is energized by the ringing current and the relay contacts control a separate power source to the signal. Dimensions are approximate, not for construction purposes. 712 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business Ex-ResistTel, FernTel IP 3A Cl. I, Div. 2, Groups A, B, C, D NEMA 3, 4X IP65, 66 Telephones for Hazardous Areas Ex-ResistTel, FernTel IP - Hazardous Area Communication Series Applications: Industrial telephones developed specifically for the harsh and hazardous environments are found in: • Oil refineries, petrochemical plants, offshore platforms, marine applications and industrial manufacturing. These telephones can handle large temperature differences found outdoors, high humidity and exposure to sea water, as well as heavy mechanical wear and tear. Features: FernTel IP – Hazardous Voice over Internet Protocol Telephone • Corrosion resistant polycarbonate housing with ½” NPT conduit entries and Type 3 (IP65) protection • Programmable with alphanumeric illuminated display and a 21-piece lighted keypad • Hermetically sealed non-contact hook sensing switch improves system reliability • Captive cover screws prevent loss during installation • Power supply: PoE (power over ethernet) with no separate power supply required • Operating Connection: 10/ 100 BASE-T Ethernet LAN • Protocoll: H323 and SIP • Operating Environment from -20°C to +55°C • Ringer Output: 95dB Ex-ResistTel FernTel IP Certifications and Compliances: Ex-ResistTel • Class I, Division 2, Groups A, B, C, D T6 • Type 4X, IP66 to EN 60529 • UL & cUL • FCC: Parts 15 and 68 hearing aid compatible • TIA-968-A & CS-03 Part 1 3A Ex-ResistTel – Hazardous Analog Telephone • Fully encapsulated electronics in robust glass fiber-reinforced polymer housing with ½” NPT conduit entries and Type 4X (IP66) protection • Programmable with alphanumeric display and a 21-piece stainless steel lighted keypad • Hermetically sealed non-contact hook sensing switch improves system reliability • Captive cover screws prevent loss during installation • Ventilation/pressure balancing plug eliminates moisture collection inside the enclosure • 10 ringing melodies, maximum 50 directory entries; multiple languages available • Operating Environment from -20°C to +40°C • Ringer output: 90dB; noise suppression: 3dB FernTel IP • Class I, Division 2, Groups A, B, C, D T5 • Type 3, IP65 to EN 60529 • UL & cUL Standard Materials: • Enclosure – Glass fiber-reinforced polymer (Ex-ResistTel); Polycarbonate (FernTel IP) • Keypad, Faceplate, Trip, Armored Cord – 316 SST Dimensions & Weights: • Ex-ResistTel – 10.5” x 9” x 5.3”; 12 lbs • FernTel IP – 12” x 8” x 5”; 5.5 lbs Ordering Information: Model Type Description Color Cat. # Ex-ResistTel Analog Keypad & Display Black 11286101110 FernTel IP VoIP Spiral Cord Yellow 11241141 FernTel IP VoIP Armored Cord Yellow 11243141 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 713 3A Cl. I, Div. 1 & 2, Groups B*, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III Telephone Accessories Power Relay Features: • ETC232 power relays are used with ESR bells and ETH, W2H or WH horns; the relay coil is energized by the telephone ringing circuit, and the relay contacts control the separate 115VAC, 60 hertz power source • ETR1 external ringer for ETW401 telephone; for low ambient noise areas, ring tone level is similar to a general use telephone; includes a ring detect relay which is powered by the telephone line voltage, (maximum 90VAC) Description Rating 3A Certifications and Compliances: Relay for Horn Signal 10A 115VAC 60 hertz • NEC/CEC: Class I, Division 1 & 2, Groups B*, C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III • UL Standard: 1203 • CSA Standard: C22.2 No. 30 Ringer Hub Size Cat. # /4" 3 ETC232 Description Normal volume external ringer for ETW40 telephone Standard Materials: • Bodies – copper-free aluminum • Covers – copper-free aluminum Standard Finishes: • Aluminum – baked epoxy powder paint *For use in Group B hazardous areas, seals must be installed within 11/ 2" of each conduit entrance. 714 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Explosionproof Dust-Ignitionproof Raintight Wet Locations Copyright© 2013 Eaton’s Crouse-Hinds Business Hub Size Cat. # / 4" ETR1 3 Transformers 4A Description Page No. XDT Hazardous Location Dry-Type Transformers see pages 716–718 4A www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 715 XDT Hazardous Location Dry-Type Transformers 4A Cl. I, Div. 2, Groups A, B, C, D NEMA 3R, 4X Resin Encapsulated Dry-Type Series Eaton's Crouse-Hinds Hazardous Location Dry-Type Transformers provide safe and efficient electric power distribution in the most extreme harsh and hazardous locations. Applications: Eaton's Crouse-Hinds Hazardous Location Dry-Type Transformers are designed to operate where volatile flammable liquids or gases are handled, processed, or used, and where ignitable concentrations of gases or vapors are normally prevented by positive mechanical ventilation, such as: • Refineries • Chemical and petrochemical plants • Mining • Corrosive process facilities • Indoor and outdoor industrial applications 4A Features: • Resin-encapsulated core-coil assembly for reliable performance in extreme environments • NEMA 3R and 4X enclosures provide essential ingress protection • 180°C insulation system with 115°C winding temperature rise creates optimal loading capabilities • Ratings: single phase - 0.5 kVA through 37.5 kVA; three phase 3 kVA through 150 kVA • Custom configurations available to meet customer specifications Certifications and Compliances: • • • • Class I, Division 2, Groups A, B, C, D NEMA 3R, 4X UL Standard 1604 cUL to C22.2 No. 66 and C22.2 No. 213-M1987 Standard Materials: • Enclosure – painted steel (NEMA 3R) or 316 stainless steel (NEMA 4X) • Windings – aluminum or copper 716 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Electrical Ratings: • • • • • • Single phase: 0.5 to 37.5 kVA Three phase: 3 to 150 kVA 180°C insulation 115°C winding temperature rise Frequency: 60 Hz Impedance: 2 to 5% Options: Description Suffix NEMA 4X ................................................................................ X Aluminum windings (three phase only) .................................. AL Copyright© 2013 Eaton’s Crouse-Hinds Business XDT Hazardous Location Dry-Type Transformers Cl. I, Div. 2, Groups A, B, C, D 4A NEMA 3R, 4X Resin Encapsulated Dry-Type Series Ordering Information - Single Phase: Primary Voltage 480V Secondary Voltage 120 / 240V NEMA kVA 3R 4X 0.5 XDT1A0A XDT1A0AX 0.75 XDT1A0B XDT1A0BX 1 XDT1A1 XDT1A1X 1.5 XDT1A1A XDT1A1AX 2 XDT1A2 XDT1A2X 3 XDT1A3 XDT1A3X 5 XDT1A5 XDT1A5X 7.5 XDT1A7 XDT1A7X 10 XDT1A10 XDT1A10X 15 XDT1A15 XDT1A15X 25 XDT1A25 XDT1A25X 37.5 XDT1A37 XDT1A37X 4A Ordering Information - Three Phase: Primary Voltage NEMA kVA 600V 480V Secondary Voltage 208Y / 120V 240V 208Y / 120V 480Y / 277V 3R 4X 3R 4X 3R 4X 3R 4X 3 XDT3B3 XDT3B3X XDT3C3 XDT3C3X XDT3D3 XDT3D3X XDT3E3 XDT3E3X 6 XDT3B6 XDT3B6X XDT3C6 XDT3C6X XDT3D6 XDT3D6X XDT3E6 XDT3E6X 9 XDT3B9 XDT3B9X XDT3C9 XDT3C9X XDT3D9 XDT3D9X XDT3E9 XDT3E9X 15 XDT3B15 XDT3B15X XDT3C15 XDT3C15X XDT3D15 XDT3D15X XDT3E15 XDT3E15X 30 XDT3B30 XDT3B30X XDT3C30 XDT3C30X XDT3D30 XDT3D30X XDT3E30 XDT3E30X 45 XDT3B45 XDT3B45X XDT3C45 XDT3C45X XDT3D45 XDT3D45X XDT3E45 XDT3E45X 75 XDT3B75 XDT3B75X XDT3C75 XDT3C75X XDT3D75 XDT3D75X XDT3E75 XDT3E75X 112.5 XDT3B112 XDT3B112X XDT3C112 XDT3C112X XDT3D112 XDT3D112X XDT3E112 XDT3E112X 150 XDT3B150 XDT3B150X XDT3C150 XDT3C150X XDT3D150 XDT3D150X XDT3E150 XDT3E150X www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 717 XDT Hazardous Location Dry-Type Transformers 4A Cl. I, Div. 2, Groups A, B, C, D NEMA 3R, 4X Resin Encapsulated Dry-Type Series Technical Details - Single Phase: NEMA 3R Painted Steel Enclosure 4A Single Phase - 480V Primary to 120 / 240V Secondary kVA Cat. # Winding Height (In.) Width (In.) Depth (In.) Weight (Lbs.) Frame Taps 0.5 XDT1A0A CU 6.5 4.9 4.7 21 57H None 0.75 XDT1A0B CU 8.4 6.0 5.5 33 58H None 1 XDT1A1 CU 8.4 6.0 5.5 35 59H None 1.5 XDT1A1A CU 10.5 6.4 6.1 52 67H None 2 XDT1A2 CU 10.5 6.4 6.1 51 68H None 3 XDT1A3 AL 14.1 7.8 8.0 79 176H None 5 XDT1A5 AL 16.0 10.4 9.9 140 177H None 7.5 XDT1A7 AL 16.0 10.4 9.9 146 178H None 10 XDT1A10 AL 19.0 13.4 10.5 240 179H None 15 XDT1A15 AL 19.0 13.4 10.5 260 180H None 25 XDT1A25 AL 28.5 22.5 14.7 409 300H None Technical Details - Three Phase: NEMA 3R Painted Steel Enclosure Three Phase - 480V Δ Primary to 208Y / 120V Secondary kVA Cat. # Winding Height (In.) Width (In.) Depth (In.) Weight (Lbs.) Frame Taps 3 XDT3B3 CU 13.4 16.0 3.4 152 201H 2 at -5% 6 XDT3B6 CU 15.9 16.5 9.9 215 200H 2 at -5% 9 XDT3B9 CU 15.9 16.5 9.9 230 103H 2 at -5% 15 XDT3B15 CU 17.4 19.7 10.7 316 95H 2 at +2.5%; 2 at -2.5% 30 XDT3B30 CU 26.6 25.3 12.8 632 243H 2 at +2.5%; 4 at -2.5% 45 XDT3B45 CU 26.5 28.5 14.6 898 244H 2 at +2.5%; 4 at -2.5% 75 XDT3B75 CU 30.8 30.1 15.6 1470 245H 2 at +2.5%; 4 at -2.5% 112.5 XDT3B112 CU 150 XDT3B150 CU Contact Customer Service Additional Information and Configurations: • Contact Customer Service for technical specifications (dimensions, weights, taps, etc.) on all other sizes. • Special configurations are available on request. Please contact Customer Service for additional details. 718 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business