Apparatus Section A

advertisement
Apparatus
Section A
Innovative, intelligent NEC and IEC solutions safely and efficiently control power
and protect circuits in explosive, wet, and corrosive environments worldwide.
New Products in the Apparatus Product Line
Section
• SynergEX Panelboards
• EID Disconnect Assembly (Fused)
• XDT Explosionproof Dry-Type Transformers
1A
2A
4A
Notable changes to the Apparatus section of this catalog
• Surge Protection Devices (previously section 4A) has been removed. For information on surge protection, please visit
Eaton's Crouse-Hinds MTL Instruments at www.mtl-inst.com
• New Section 4A for transformers
Apparatus
A
Table of Contents
Section A of the Eaton's Crouse-Hinds catalog contains the following product groupings:
Section 1A
Panelboards
(for use in hazardous and non-hazardous areas)
For central control and protection of a large number of feeder or
branch circuits and for housing of circuit breakers.
D2L
XLPB
D2PB
EXD
D2D
GUSC
EPL
D2Z
LP
N2PB
SPB
NLP
Section 2A
Switches
A
(for use in hazardous and non-hazardous areas)
Switches and enclosures for disconnecting motor, lighting and other
circuits.
EDS, EDSC
NST
FSPC
EFD, EFDC
NRS
GUSC
FLS
6810 Series
WST
EID
7810 Series
GHG
N2RS
EBM
Section 3A
Instrument Housings
(for use in hazardous areas)
Housings for a variety of types and makes of meters and
instruments, thermostats, heaters and clocks.
HRC
ETW
TCH
ETC
EXH
ETR
XC
D2TW
Section 4A
Transformers
Provide safe and efficient electric power distribution in the
most extreme harsh and hazardous locations.
XDT
624
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
1A
Panelboards
Hazardous and Non-hazardous
Description
Page No.
General Information
see page 626
Application/Selection
see page 627
Wiring Diagrams
see page 628
Hazardous Location Panelboards
see page 641
see page 634
see pages 650–653
see page 630
see pages 667–668
see page 641
see page 634
see page 630
see page 663
see pages 669–671
see pages 667–668
see page 654
Ordinary Location
XLPB
NLP Series
www.crouse-hinds.com
US: 1-866-764-5454
see page 672
see page 675
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
625
1A
Division 1 and 2
PowerPlus™ EXD
PowerPlus™ EPL
SynergEX SPB
Exactra™ LP
GUSC
Division 2
PowerPlus™ D2D
PowerPlus™ D2L
Exactra™ LP
D2PB
N2PB
GUSC
D2Z
1A
Circuit Breaker Panelboards
General Information
Applications:
Ratings
Circuit breaker panelboards are used in
hazardous and non-hazardous areas (as
shown in the individual listings):
• To provide, in one compact unit, a
centrally controlled switching system for
a large number of feeder or branch
circuits
• For controlling lighting, heating,
appliance, heat tracing, motor and
similar circuits
• In locations where rough usage,
moisture, dust, dirt and corrosion are a
problem
• To house thermal-magnetic circuit
breakers that provide disconnect means,
short circuit protection and thermal time
delay overload protection
Single and two-pole,
W-C-375a, Class 1a
120 / 240 VAC
Two and three-pole,
W-C-375a, Class 1b
240 VAC
1A
Features:
Panelboards:
• All main and branch circuit wire lugs are
solderless and readily accessible for
fast, easy installation
• Are factory wired from main terminal
blocks or main bus to line side of branch
circuit breakers
• With circuit breakers in factory sealed
housings (LP1, EXD and EPL), are also
factory wired from the load side of
branch circuit breakers to readily
accessible terminal blocks
• With circuit breakers grouped in one
enclosure (LP2, D2D, D2L, D2Z and
D2PB factory sealed), branch circuit
wires are attached directly to circuit
breaker load terminals
Circuit breakers (thermal magnetic):
• Are trip-free of the handles and cannot
be held closed under short circuit or
overload conditions
• Four breaker types are used in
panelboards manufactured by Eaton's
Crouse-Hinds. They are as follows:
• Quicklag® – used in LP, D2PB, EPL and
D2L panelboards; 10,000 ampere
symmetrical interrupting capacity
Fed. Spec.
Standard Materials,
Finishes, Options and
Compliances:
• See individual listing pages
• EHD/FDB frame – used in EXD and D2D
panelboards; 14,000 ampere
symmetrical interrupting capacity
- 480 VAC
Ratings
Fed. Spec.
Single-pole, 277 VAC
W-C-375a, Class 2a
or 125 VDC
Two and three-pole
N/A
480 VAC or 250 VDC
Wiring Systems:
• See pages 628 and 629 for wiring
diagrams. These are the standard
systems used for single and three-phase
panelboards having single, two and
three-pole circuit breakers
• Standard panelboards are listed with all
circuit breakers having the same number
of poles and wired for one of these
systems
• To meet the requirements of a specific
installation, panelboards can be
assembled with a combination of single,
two and three-pole breakers. To
accomplish this, the three individual
wiring systems must have the same
main service as, for example, 3-phase,
4-wire, solid neutral.
Panelboard Type
Applicable
Wiring
Systems
D2PB
3, 4, 5, 8, 11, 12
• Diagrams show only four, six or eight
circuits; are intended to show only the
phase connections of each circuit
breaker and do not necessarily show
their physical location in a panelboard.
Panelboards are available with the number
of circuits indicated in the listings.
Quicklag is a registered trademark of Cutler-Hammer Inc.
626
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
1A
Circuit Breaker Panelboards
Quick Selector Chart
Quick Selector Chart
Panelboard
D2D
NEC & NEMA
Certifications and
Compliances
Cl. I, Div. 2, Groups B, C, D
NEMA: 3, 4, 7BCD, 12
Factory
Sealed
Yes
Number
Circuits
Max.
42
Breaker
Frame
Size
Various
Multi-Pole
Voltage
Max.
600VAC
250VDC
Trip
Rating
Amps
Max.
100
Circuit
Interrupting
Amps
Max.
10,000
Step
Down
Transformer
Available
Yes
Cl. I, Div. 2, Groups B, C, D
NEMA: 3, 4, 7BCD, 12
Yes
42
Quicklag®
240VAC
125VDC
100
10,000
Yes
D2PB
Cl. I, Div. 2, Groups C, D
NEMA: 3, 7CD (Div. 2), 12
Yes
24
Quicklag®
240VAC
30
10,000
Yes
D2Z
Cl. I, Zone 1, Div. 2,
Groups A, B, C, D
NEMA: 3, 4X, 7ABCD (Div. 2), 12
Corrosion Resistant,
Non-Metallic
Yes
54
CEAG
480VAC
180
10,000
No
EPL
Cl. I, Div. 1 & 2, Groups B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA: 3, 4, 7BCD, 9EFG, 12
Yes
42
Quicklag®
240VAC
125VDC
100
10,000
No
EXD
Cl. I, Div. 1 & 2, Groups B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA: 3, 4, 7BCD, 9EFG, 12
Yes
42
Various
600VAC
250VDC
100
10,000
No
GUSC
Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA: 3, 7CD, 9EFG, 12
No
2
Quicklag®
240VAC
30
10,000
No
LP1
Cl. I, Div. 1 & 2, Groups B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA: 3, 4X, 7BCD, 9EFG, 12
Yes
36
Quicklag®
240VAC
100
10,000
No
LP2
Cl. I, Div. 2, Groups B, C, D
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA: 3, 4X, 7BCD, 9EFG, 12
Yes
36
Quicklag®
240VAC
100
10,000
Yes
N2PB
Cl. I, Div. 2, Groups C, D
Cl. II, Div. 2, Groups F, G
NEMA: 3, 7CD, (Div. 2), 12
Corrosion Resistant,
Non-Metallic
Yes
24
Quicklag®
240VAC
30
10,000
No
NLP
NEMA 3, 12
No
30
QO/Qwik-Guard®
240VAC
100
10,000
No
SPB
Class I, Zone 1
Cl. I, Div. 2, Groups A, B, C, D
Cl. II, Div. 1, Groups E, F, G
Yes
60
Various
480VAC
40
10,000
No
XLPB
NEMA 1, 3, 3R, 4, 4X, 12
No
42
Various
600VAC
100
10,000
Yes
1A
D2L
Quicklag is a registered trademark of Cutler-Hammer Inc. QO/Qwik-Guard is a registered trademark of Square D.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
627
1A
Circuit Breaker Panelboards
Wiring Diagrams
D2PB Panelboards
System 3
Mains—3-Wire
Branches—3-Wire
Breakers—2-Pole
Solid Neutral
System 4
Mains—3-Wire
Branches—2-Wire
Breakers—Single-Pole
Solid Neutral
System 5
Mains—4-Wire, 3-Phase
Branches—2-Wire, 1-Phase
Breakers—Single-Pole
Solid Neutral
System 7
Mains—2-Wire
Branches—2-Wire
Breakers—Single-Pole
Solid Neutral
System 8
Mains—4-Wire, 3-Phase
Branches—3-Wire, 1-Phase
Breakers—2-Pole
Solid Neutral
System 13
Mains—4-Wire, 3-Phase
Branches—2-Wire, 1-Phase
Breakers—2-Pole
System 15
Mains—4-Wire, 3-Phase
Branches—3-Wire, 1-Phase
Breakers—Single-Pole
Solid Neutral
System 24
Mains—3-Wire
Branches—2-Wire
Breakers—Single-Pole
Solid Neutral
System 25
Mains—4-Wire, 3-Phase
Branches—2-Wire, 1-Phase
Breakers—Single-Pole
Solid Neutral
System 28
Mains—4-Wire, 3-Phase
Branches—3-Wire, 1-Phase
Breakers—2-Pole
Solid Neutral
System 29
Mains—3-Wire, 3-Phase
Branches—2-Wire, 1-Phase
Breakers—2-Pole
1A
System 1
Mains—2-Wire
Branches—2-Wire
Breakers—2-Pole
628
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
1A
PowerPlus™ Lighting Panelboards
Wiring Diagrams
PowerPlus™ Power Panelboards
1A
Single Phase Circuit
Three Phase Circuit
PowerPlus™ Lighting Panelboards
Single Phase Circuit
www.crouse-hinds.com
Three Phase Circuit
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
629
1A
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. II, Div. 1, Groups E†, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 4*, 4X§, 7B†CD, 9EFG, 12
Exactra™ Panelboards
Lighting and Heat Tracing
LP1 Series
LP2 Series (Div. 2)
Exactra™ Factory-Sealed Lighting
Panelboards provide flexibility and labor
savings when installed, and for future
changes in the field. Panels are prewired to
maximum circuit capacity and ratings.
1A
Applications:
Exactra™ Factory-Sealed Lighting
Panelboards are ideal:
• In areas made hazardous by the
presence of flammable gases and
vapors, and combustible dusts
• In areas subject to weather, dampness,
and corrosion
• For branch power distribution and circuit
protection for motors, valves, pumps,
lighting, heat tracing, receptacles, etc.
• For indoor and outdoor applications in
petroleum refineries, chemical and
petrochemical plants, and other process
industry facilities where similar hazards
exist
• In areas where flammable vapors or
gases or highly combustible dusts may
be present due to accidental or
abnormal conditions
• To accommodate up to 35 amp branch
loads
Features and Benefits:
• Factory sealed, no external seals
required for branch circuits. External
seals are required for Class I, Div. 1
applications
• Fully wired for circuit breaker housing to
pre-numbered terminals in wiring
compartment
• External flange design allows wide
unobstructed cover opening for easy
wiring access
• External circuit breaker handles can be
padlocked "ON" or "OFF"
• Furnished with two 3" and ten 11/2"
conduit openings
• Breather and drains available for each
enclosure
• Available with or without main circuit
breaker up to 100 amps
• Isolated neutral and ground bar provided
• Available with up to 6 GFI and/or EPD
branch breakers per panel. GFI and EPD
branch breakers available within the
same panel
• Available with ambient compensated
breakers throughout panelboard
• Stainless steel hinges allow the cover to
swing wide open or be removed
• Stainless steel hex head bolts captive
design prevents lost bolts
• Cast copper-free (less than 0.4%)
aluminum construction for excellent
corrosion resistance
• Neoprene cover gasket meets NEMA 4 /
CSA Enc. 4 / IP65 requirements,
provides watertight seal for superior
water and corrosion protection
• Copper bus bar system
630
www.crouse-hinds.com
US: 1-866-764-5454
CSA Enc. 3, 4*, 5
Explosionproof
Dust-Ignitionproof
Factory Sealed‡
Wet Locations
Watertight
Certifications and
Compliances:
LP1 panelboards
•
•
•
•
•
•
•
•
•
Class I, Groups B, C, D
Class I, Zone 1 & 2, IIB + H2
Class II, Groups E, F, G
Class III
NEMA 3, 4*, 4X§, 7B†CD, 9E†FG, 12
CSA Enc. 3, 4*, 5
IP65* Enclosure
UL Classified (Standard 1203)
cUL Classified (Certified by UL to CSA
C22.2 No. 30)
LP2 Panelboards
•
•
•
•
•
•
•
•
•
Class I, Division 2, Groups B†, C, D
Class I, Zone 1 & 2, IIB + H2
Class II, Division 2, Groups F, G
Class III
NEMA 3, 4*, 4X§, 7BCD (Div 2),
9EFG, 12
CSA Enc. 3, 4*, 5
IP65* Enclosure
UL Classified (Standard 1203)
cUL Classified (Certified by UL to CSA
C22.2 No. 30)
Standard Materials:
• Body and cover – cast copper-free
aluminum
• Gasket – neoprene
• Operating handles – extruded aluminum
(copper-free)
• Operating shafts, cover bolts, washers,
GFI/EPD plungers and hinges – stainless
steel
• Circuit breaker operator forks –
- for 1 pole standard breakers - die-cast
aluminum (copper-free)
- for 1 and 2 pole GFI / EPD breakers die-cast aluminum (copper-free)
- for 2 and 3 pole standard breakers stainless steel
• Lifting bracket – cold rolled steel
• Bus bar – copper
Standard Finishes:
• Aluminum – natural
• Stainless steel – natural
• Cold rolled steel – electrogalvanized
* NEMA 4/CSA Enc. 4/IP65 hosetight with breather and
drain openings plugged.
† With suffix -GB.
‡ External seals required for Class I, Div. 1.
§ NEMA 4X when ordered with suffix S752 with breather
and drain openings plugged.
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
LP1 Lighting Panelboard
Exactra™ Panelboards
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. II, Div. 1, Groups E†, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 4*, 4X§, 7B†CD, 9EFG, 12
Lighting and Heat Tracing
LP1 Series
LP2 Series (Div. 2)
1A
CSA Enc. 3, 4*, 5
Explosionproof
Dust-Ignitionproof
Factory Sealed‡
Wet Locations
Watertight
Electrical Ratings:
Options:
Breaker Options:
Branch Breaker (120 / 240 VAC
Quicklag® Bolt On) Trip Ratings
• 1, 2, 3 pole
10, 15, 20, 25, 30, 35 amp
• GFI type 1, 2-pole (5 mA sensitivity)
15, 20, 25, 30 amp
• EPD type 1, 2-pole (30 mA sensitivity)
15, 20, 25, 30 amp
Main Breaker Trip Ratings:
• Size B & C
10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60,
70, 80, 90, 100 amp
2, 3-pole
Main Lugs
• Size B & C
100 amp
Description
Suffix
• Alternate feed: incoming power
into terminal enclosure from
bottom . . . . . . . . . . . . . . . . . . . . .
A
• Group B and E suitability
(10A not avail.) . . . . . . . . . . . . . . .
GB
• Lamicoid nameplate with
customer-specified panel
identification . . . . . . . . . . . . . . . . . LID
• Stainless steel nameplate with
customer-specified panel
identification . . . . . . . . . . . . . . . . . SID
• 125W@120 VAC, 250W@240 VAC
internal space heater in circuit
breaker enclosure . . . . . . . . . . . . . R22
• External epoxy powder
coat finish . . . . . . . . . . . . . . . . . . . S752
• Internal and external epoxy
powder coat finish . . . . . . . . . . . . S753
• One breather and two drains per
enclosure . . . . . . . . . . . . . . . . . . . S756V
• All conduit entries plugged with
PLG recessed head plugs . . . . . . S822
• All conduit entries plugged with
square headed plugs . . . . . . . . . . S872
• To order an inverted panelboard
with all conduit openings for
power and branch circuits on the
bottom (inverted) . . . . . . . . . . . . . .
I
Description
Suffix
• EPD branch breaker (up to 6 EPD
and/or GFI per panel) . . . . . . . . . . .
E
• GFI branch breaker (up to 6 EPD
and/or GFI per panel) . . . . . . . . . . .
G
• Ambient compensated (50°C)
breakers throughout panelboard . .
V
• HID branch breaker for lighting
loads . . . . . . . . . . . . . . . . . . . . . . . .
H
Weight
• 150 lbs.
In Inches:
Description
Cat. #
• Extra circuit breaker operator
assemblies 1-pole (qty. 3) . . . . . .
• Replacement cover plugs for
unused circuit breaker positions
(qty. 6). . . . . . . . . . . . . . . . . . . . . .
• Extra circuit breaker operator
assemblies for 1 pole and 2 pole
GFI/EPD breakers (qty. 3). . . . . . .
• GFI/EPD "push to test" plungers
(qty. 6). . . . . . . . . . . . . . . . . . . . . .
• GFI/EPD entry plugs (qty. 6). . . . .
• Replacement mounting feet
(qty. 2). . . . . . . . . . . . . . . . . . . . . .
• Extra circuit breaker operator
assembies for 2 pole standard
and GFI/EPD breakers . . . . . . . . .
• Extra circuit breaker operator
assembies for 3 pole breakers. . .
LP K1
LP K2
LP K3
LP K4
LP K5
LP K6
LP K7
LP K8
Panel Capacity:
Panel
Size
With Main With Main Breaker
Lug Only
2-pole
3-pole
Available
w/GFI,
Main
EPD
Breaker
Branch
Max. Amp Protection
B
C
24
36
100
100
Max. No. of Branch Spaces
22
34
21
33
Yes
Yes
* NEMA 4/CSA Enc. 4/IP65 hosetight with breather and drain openings plugged.
† With suffix -GB.
‡ External seals required for Class I, Div. 1.
§ NEMA 4X when ordered with suffix S752 with breather and drain openings plugged.
Quicklag® is a registered trademark of Cutler-Hammer Inc.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
631
1A
Dimensions
Lighting Panelboard
Accessories:
Exactra™ Panelboards
1A
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. II, Div. 1, Groups E†, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 4*, 4X§, 7B†CD, 9EFG, 12
Lighting and Heat Tracing
LP1 Series
LP2 Series (Div. 2)
Ordering Information
1.
LP1 & LP2 Factory Sealed 120 / 240 Volt Lighting
Panelboards
1A
Division 1
Division 2
Branch
Spaces
Needed
1 Phase
3 Wire
3 Phase
4 Wire
1 Phase
3 Wire
3 Phase
4 Wire
6
8
10
12
14
16
18
20
20
22
22
24†
24
26
28
30
32
34
36†
Breaker Ready■
(Empty)
LP1B106
LP1B108
LP1B110
LP1B112
LP1B114
LP1B116
LP1B118
LP1B120
LP1C120
LP1B122
LP1C122
LP1B124†
LP1C124
LP1C126
LP1C128
LP1C130
LP1C132
LP1C134
LP1C136†
LP1B100
LP1C100
LP1B306
LP1B308
LP1B310
LP1B312
LP1B314
LP1B316
LP1B318
LP1B320
LP1C320
LP1B322
LP1C322
LP1B324†
LP1C324
LP1C326
LP1C328
LP1C330
LP1C332
LP1C334
LP1C336†
LP1B300
LP1C300
LP2B106
LP2B108
LP2B110
LP2B112
LP2B114
LP2B116
LP2B118
LP2B120
LP2C120
LP2B122
LP2C122
LP2B124†
LP2C124
LP2C126
LP2C128
LP2C130
LP2C132
LP2C134
LP2C136†
LP2B100
LP2C100
LP2B306
LP2B308
LP2B310
LP2B312
LP2B314
LP2B316
LP2B318
LP2B320
LP2C320
LP2B322
LP2C322
LP2B324†
LP2C324
LP2C326
LP2C328
LP2C330
LP2C332
LP2C334
LP2C336†
LP2B300
LP2C300
2.
† Items are not available with main circuit breaker.
■ Provided for main lug only; main breaker must be specified with amperage.
Catalog Number Example:
Lighting Panelboards can be furnished with an assortment of breaker
ratings and pole configurations. Assortments may be ordered by
adding the number of poles and amp rating designations to the
catalog number.
Example:
A three-phase, Class I, Div. 2, Groups C, D lighting panelboard with:
• 5 three-pole breakers – with 15 amp rating
• 6 single-pole breakers – with 20 amp GFI personnel protection
• Three-pole main breaker – with 100 amp rating
• Alternate feed option
• Breather and drain option
3.
4.
Select basic panelboard catalog number from listing:
• Determine phase (available with single-phase or
three-phase wiring).
• Determine a total even number of breaker spaces needed to
complete your desired lighting panelboard.
Note:
3 breaker spaces = Three-pole breaker
2 breaker spaces = Two-pole breaker
2 breaker spaces = Two-pole GFI (or EPD) breaker
1 breaker space = Single-pole breaker
1 breaker space = Single-pole GFI (or EPD) breaker
• Review Panel Capacity table see page 631
• If GFI or EPD breakers are to be included insert "G", "E" or
"EG" after base catalog number (e.g., LP2B316G).
• Maximum number of GFI and/or EPD breaker spaces is
6 per panel. (e.g. 6 single-pole or 3 two-pole).
For more, consult factory.
• If ambient compensated breakers are required, insert "V"
(e.g. LP2B318GV).
Using three-pole branch breakers first, select circuit breakers
for lighting panel board application:
• Place an asterisk (*) before each quantity of circuit breakers
• First insert the quantity of breakers needed.
• Second insert the quantity of poles (start with three-pole
breakers).
Note: Single-phase panelboards can have single- or two-pole
breakers. Three-phase panelboards can have single, two- or
three-pole breakers.
• Third insert the ampere rating needed (start with highest
ampere rating).
• Insert "G" for GFI or "E" for EPD type breakers, if desired.
For additional circuit breakers repeat step 2. If there are more
three-poles with different amp ratings, then continue with threepole designations. Otherwise continue with two-pole circuit
breakers, and then single-pole breakers.
To add a main breaker, insert a space, the number of poles
(2 or 3), an "M" to indicate main breaker, then indicate the amp
rating (See "ratings" for trip ratings available). If no main breaker
is specified, the panelboard will have main lugs. No suffix
needed in catalog number for main lug only.
For future spaces, to provide for operating mechanism without
breaker write 00 (e.g. one three-pole mechanism without
breaker: 01300).
Unused breaker positions without designations will be blanked
and plugged. Complete panel will be provided for future breaker
installations.
* NEMA 4/CSA Enc. 4/IP65 hosetight without suffix S756V.
‡ External seals required for Class I, Div. 1.
§ NEMA 4X when ordered with suffix S752 without suffix S756V.
†With suffix -GB.
632
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
CSA Enc. 3, 4*, 5
Explosionproof
Dust-Ignitionproof
Factory Sealed‡
Wet Locations
Watertight
Copyright© 2013 Eaton’s Crouse-Hinds Business
Exactra™ Panelboards
Lighting and Heat Tracing
LP1 Series
LP2 Series (Div. 2)
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. II, Div. 1, Groups E†, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 4*, 4X§, 7B†CD, 9EFG, 12
CSA Enc. 3, 4*, 5
Explosionproof
Dust-Ignitionproof
Factory Sealed‡
Wet Locations
Watertight
1A
Wiring Diagrams:
1A
* NEMA 4/CSA Enc. 4/IP65 hosetight without suffix S756V.
‡ External seals required for Class I, Div. 1.
§ NEMA 4X when ordered with suffix S752 without suffix S756V.
†With suffix -GB.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
633
1A
PowerPlus™ Panelboards
Lighting and Heat Tracing
EPL Series (Div. 1 & 2)
D2L Series (Div. 2)
EPL Series:
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Zone 1 & 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12
D2L Series:
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Zone 2, IIB + H2†
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
PowerPlus™ Series Panelboards provide
both premium factory-sealed and value
non-factory-sealed solutions for the
protection and distribution of lighting,
power, and heat tracing circuits. This panel
solution is designed, engineered, and
manufactured to be the industry’s safest
and most dependable panelboard for
hazardous area locations.
1A
PowerPlus Premium and
Value Solutions
• Premium Solution: PowerPlus factorysealed panelboards are premium
panelboards that provide maximum
circuit flexibility with labor savings during
installation, operation, and maintenance,
and are accommodating for future
changes in the field (order with either
“S” or “A” in base part number). Panels
are pre-wired to maximum circuit
capacity, allowing for easy and safe
replacement or installation of
components in the field, while
maintaining factory-sealed integrity.
• Value Solution: PowerPlus non-factorysealed panelboards are value
panelboards that offer maximum circuit
flexibility and many of the same features
and benefits of the PowerPlus premium
line. This value solution is provided
without terminal housing and factory
wiring of circuits (order with “N” in base
part number). The non-factory-sealed
solution reduces initial panelboard
material costs and requires field wiring
to circuit breakers and external seals to
be field-installed during installation.
Applications:
EPL and D2L PowerPlus™ panelboards are
used:
• In areas made hazardous by the
continuous or abnormal presence of
flammable gases, vapors, and
combustible dusts
• In areas subject to weather, dampness,
and corrosion
• For branch power distribution and circuit
protection to motors, valves, pumps,
lighting, heat tracing, receptacles, etc.
• For indoor and outdoor applications in
petroleum refineries, chemical and
petrochemical plants, and other process
industry facilities where similar hazards
exist
• To accommodate up to 100 amp branch
loads (only 3 circuits), balance is up to
50 amps
Certifications and
Compliances:
Standard Materials
and Finishes:
EPL Series:
• Circuit breaker enclosure body and
cover – copper-free aluminum
• Terminal housing – type 316L stainless
steel ("S") or copper-free aluminum ("A")
• Gasket – neoprene (cast aluminum
enclosure); foam-in-place (stainless steel
enclosure)
• Operating handles – copper-free
aluminum
• Operating shafts and bushings, cover
bolts, washers, hinges, breather/drain,
retractile springs – stainless steel
• Circuit breaker operators – non-metallic
• Lifting bracket – electrogalvanized cold
rolled steel
• Chassis – silver-plated copper
• Breather cap – Delrin® non-metallic
material
• Neutral and ground bar – tin-plated
aluminum
• NEC/CEC:
Class I, Division 1 & 2, Groups B†, C, D
Class I, Zone 1 & 2, IIB + H2†
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• NEMA/EEMAC: 3, 4, 4X‡, 7B†CD,
9EFG, 12
• CSA Enc. 3, 4, 5
• UL Standard: 67, 1203
• cUL (to CSA Standard C22.2
Nos. 29 & 30)
• IP65
D2L Series (Division 2):
• NEC/CEC:
Class I, Division 2, Groups B†, C, D
Class I, Zone 2, IIB + H2†
Class II, Division 2, Groups F, G
Class III
• NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
• CSA Enc. 3, 4, 5
• UL Standard: 67, 1203
• cUL (to CSA Standard C22.2
Nos. 29 & 30)
• IP65
† Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers.
To order with brackets installed at factory, add suffix -GB. For field installable kit, order EPL-GB-KIT separately.
‡ NEMA 4X rating is available when ordered with suffix S752 or S753.
Delrin® is a registered trademark of DuPont.
634
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
PowerPlus™ Panelboards
Lighting and Heat Tracing
EPL Series (Div. 1 & 2)
D2L Series (Div. 2)
EPL Series:
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Zone 1 & 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12
D2L Series:
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Zone 2, IIB + H2†
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
1A
1A
† Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers.
To order with brackets installed at factory, add suffix -GB. For field installable kit, order EPL-GB-KIT separately.
‡ NEMA 4X rating is available when ordered with suffix S752 or S753.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
635
1A
PowerPlus™ Panelboards
D2L Series:
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Zone 2, IIB + H2†
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
1A
Lighting and Heat Tracing
EPL Series (Div. 1 & 2)
D2L Series (Div. 2)
EPL Series:
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Zone 1 & 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12
† Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers.
To order with brackets installed at factory, add suffix -GB. For field installable kit, order EPL-GB-KIT separately.
‡ NEMA 4X rating is available when ordered with suffix S752 or S753.
636
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
PowerPlus™ Panelboards
Lighting and Heat Tracing
EPL Series (Div. 1 & 2)
D2L Series (Div. 2)
EPL Series:
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Zone 1 & 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12
Electrical Ratings:
Accessories:
Branch Breakers (120/240VAC Quicklag® Bolt-On)
Trip Ratings:
Gland Plates
D2L Series:
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Zone 2, IIB + H2†
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
1A
Field installable gland plates with factory-provided aluminum
Myers™ Hubs for the D2L stainless steel terminal housing (one
3-inch hub and 12 branch entry hubs - size dependent upon suffix,
each kit includes 3 gland plates, 1 for the top or bottom and 1 for
each side):
Part Number
3
/4" branch entry hub
D2L HUB2 KIT
1" branch entry hub
D2L HUB3 KIT
1 1/2" branch entry hub
D2L HUB5 KIT
Replacement gland plate (no hubs)
D2L HUB0 KIT
• 1-, 2-, and 3-pole
• 10, 15, 20, 25, 30, 35, 40, 45, 50 amp (available in all breaker
spaces in panel), 55, 60, 70, 80, 90, 100 amp (only 3 breaker
spaces available for 55 to 100 amp branch breakers)
• GFI type, 1- and 2-pole (5mA sensitivity) 15, 20, 25, 30, 40 (50
amp - available 2-pole only)
• EPD type, 1- and 2-pole (30mA sensitivity) 15, 20, 25, 30, 40 (50
amp - available 2-pole only)
• HID type, 1- and 2-pole, 15, 20, 25, 30, 35, 40, 50, 60
• Available with GFI, EPD, or a combination of both in one panel
with a 21-position electrical test circuit
• Ambient compensated breakers available to +50°C
Circuit Breaker Operator Assemblies:
Operator Assemblies
D2L/EPL 1-pole or 3-pole breakers
D2L/EPL 2-pole breakers
Main Breaker Trip Ratings:
Part Number
EPL HDL13
EPL HDL2
Replacement Cover Plugs:
• 2- or 3-pole
• Size B: 10 to 100 amps
• Size C and D: 10 to 225 amps
For unused circuit breaker positions (qty. 5):
Plug Kits
D2L/EPL Sizes B, C, D
Main Lugs:
• Size B, C, and F: 225 amps
• Size D: not available; main breaker only
Part Number
EPL OP PLG
Kit for Group B
To add the following features to the panelboard, add a dash and then
the suffix to the Cat. No. When multiple suffixes are needed, add
them to the Cat. No. in alpha-numeric order.
Description
Suffix
Space heater................................................................................. R22
Square head plugs on all conduit openings.................................
SP
Epoxy powder coat finish, external .............................................. S752
Epoxy powder coat finish, internal and external .......................... S753
Recess head plugs on all conduit openings ................................ RP
Stainless steel breaker operator cover (ice shield)....................... HG
Group B kit factory installed ......................................................... GB
GFI breakers .................................................................................
G
EPD breakers ................................................................................
E
HID breakers .................................................................................
H
Ambient compensated breakers (50ºC)........................................
V
Lamacoid Nameplate.................................................................... LID
D2L/EPL Stainless Steel Breaker Operator Cover
To protect operators from ice build-up for all
D2L/EPL PowerPlus panels:
Kit for Size B panel
Kit for Size C and D panel
Part Number
EPL-HG24-KIT
EPL HG42-KIT
Space Heater Kit
D2L/EPL PowerPlus Panels
EPL R22 KIT
Terminal Housing Mounting Plate Kit:
To adapt depth of terminal housing to same
depth as breaker enclosure ***
Panel Types / Sizes
Part Number
Terminal Housing
D2L/EPL Sizes B, C, D
EPLA-MTG-KIT
Aluminum
D2L Sizes B, C, D
D2LS-MTG-KIT
Stainless
A standard panelboard has conduit openings for power
and branch circuits on top.
To order a panelboard with main power feed from the bottom
of breaker housing, and branch entries on top (alternate) ........... -A**
To order an inverted panelboard with all conduit openings for
power and branch circuits on the bottom (inverted) ....................
-I
To order an inverted panelboard with main power feed on
top and bottom (alternate inverted) .............................................. -A-I**
† Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers.
To order with brackets installed at factory, add suffix -GB. For field installable kit, order EPL-GB-KIT separately.
‡ NEMA 4X rating is available when ordered with suffix S752 or S753.
** Not available in D2L/EPL Size D panels.
*** The weight of the panel is sufficiently supported by mounting of breaker enclosure.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
637
1A
Options:
Standard panels less -GB suffix are applicable for Group B,
but it is required to install brackets on breakers.
Part Number
To order brackets factory installed
add suffix -GB
For field installable kit
EPL GB KIT
PowerPlus™ Panelboards
1A
Lighting and Heat Tracing
EPL Series (Div. 1 & 2)
D2L Series (Div. 2)
EPL Series:
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Zone 1 & 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12
D2L Series:
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Zone 2, IIB + H2†
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
Table A – Panel Capacity
Maximum Number of Breaker Spaces:
Panel
Size
Max. No. of Branch Circuit Breaker Spaces
With Main
With Main Breaker
Lug Only
2-pole
3-pole
Available Main
Breaker
Ampacity
Available
With GFI, EPD
Branch Protection
B
24
C§
42
D
42
Up to 100■
Up to 100■
110 to 225✪
Up to 225✪
Yes
Yes
Yes
Yes
22
40
36
42
21
39
36
42
Table B – To Size Panels with GFI or EPD
Branch Breakers
1A
Maximum Number of GFI or EPD Breakers
Panel Size
with Main Lug
or Main
SingleTwoBreaker
Pole
Pole
B
C
D
12
(10 with 3-pole MCB,
11 with 2-pole MCB)
21
14
EPLDN only - can go up to 42 GFI or EPD circuits.
EPLDN will accommodate up to 225 amp main
breaker.
21
Each factory-sealed panel is equipped with 42 load wires for
GFI/EPD breakers and any combination with standard branch
breakers. Determine the total number of load wires required to
complete your panel. You may not exceed 42 load wires.
Load Wires Required
Single-pole breaker
1
Single-pole GFI (or EPD) breaker
2
Two-pole breaker
2
Two-pole GFI (or EPD) breaker
3
Three-pole breaker
3
Maximum Total: 42 load
wires (factory sealed)
Maximum Total: 84 load
EPLDN Panels
wires (non-factory sealed)
† Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with
brackets installed at factory, add suffix -GB. For field installable kit, order EPL-GB-KIT separately.
‡ NEMA 4X rating is available when ordered with suffix S752 or S753.
§ All size B and size C panels with main breaker rated up to 100 amps use a back-fed branch breaker. All size D and size C panels with main breaker rated from 110 amps to 225 amps
have a dedicated location for main breaker. Size C ordered with suffix 2M00 or 3M00 are provided with 36 branch circuits for maximum breaker ampacity.
✪ Main breakers are mounted external to chassis.
■ Main breakers are chassis mounted and back-fed.
638
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
PowerPlus™ Panelboards
Lighting and Heat Tracing
EPL Series (Div. 1 & 2)
D2L Series (Div. 2)
EPL Series:
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Zone 1 & 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12
D2L Series:
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Zone 2, IIB + H2†
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
1A
Lighting Panelboard Catalog Number Example
Example:
Class I, Division 2 / Zone 2, Group B panel with:
• 240VAC lighting panelboard
• (28) single-pole 20 amp branch breakers
• (1) single-pole 15 amp branch GFI breaker
• 225 amp 3-pole main circuit breaker
1A
† Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with
brackets installed at factory, add suffix -GB. For field installable kit, order EPL-GB-KIT separately.
‡ NEMA 4X rating is available when ordered with suffix S752 or S753.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
639
1A
PowerPlus™ Panelboards
Lighting and Heat Tracing
EPL Series (Div. 1 & 2)
D2L Series (Div. 2)
Dimensions
Size B Panel*
(With Stainless Steel Terminal Housing)
EPL Series:
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Zone 1 & 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12
Size C and D Panel*
(With Cast Terminal Housing)
6.50 (165.1)
4.66 (118.4)
2.81 (71.4)
6.50
(165.1)
1-1/2" NPT
12 PLACES
1.83 (46.5)
20.12
(511.0)
D2L Series:
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Zone 2, IIB + H2†
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
4.66
(118.4)
2.81
(71.4)
5.10
3.51
(129.5) (89.2)
TYP.
TYP.
.92 (23.4)
1/2" BOLT (M12)
1.31 (33.3)TYP.
CL
.50 (12.7)
3/8"
BOLT (M9)
5.50 (139.7)
11.16 (283.5)
12.93 (328.4)
APPROXIMATE
4.00 (101.6)
1A
11.52 (292.6)
APPROXIMATE
3 1/2" NPT
3 1/2" NPT
ALTERNATE FEED OPTION
(SUFFIX 'A') ONLY
61.75
(1568.5)
48.63
(1235.2)
29.50 (749.3)
17.50 (444.5)
6.00 (152.4)
14.88 (377.8)
TYP.
5.75 (146.0)
14.88 (377.8) TYP.
† Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers.
To order with brackets installed at factory, add suffix -GB. For field installable kit, order EPL-GB-KIT separately.
‡ NEMA 4X rating is available when ordered with suffix S752 or S753.
*Stainless steel and cast aluminum terminal housing for Sizes B, C, and D are the same. Note: Value series non-factory-sealed EPL*N panel dimensions are the breaker housing only and use
standard entries shown on cast terminal housing.
640
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
EXD Series:
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Zone 1 & 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12
PowerPlus™ Panelboards
Power
EXD Series (Div. 1 & 2)
D2D Series (Div. 2)
PowerPlus™ Series Panelboards provide
both premium factory-sealed and value
non-factory-sealed solutions for the
protection and distribution of lighting,
power, and heat tracing circuits. This panel
solution is designed, engineered, and
manufactured to be the industry’s safest
and most dependable panelboard for
hazardous area locations.
PowerPlus Premium and
Value Solutions
Applications:
EXD and D2D PowerPlus™ panelboards are
used:
• In areas made hazardous by the
continuous or abnormal presence of
flammable gases, vapors, and
combustible dusts
• In areas subject to weather, dampness,
and corrosion
• For branch power distribution and circuit
protection to motors, valves, pumps,
lighting, heat tracing, receptacles, etc.
• For indoor and outdoor applications in
petroleum refineries, chemical and
petrochemical plants, and other process
industry facilities where similar hazards
exist
• To accommodate up to 100 amp branch
loads (only 3 circuits), balance is up to
50 amps
1A
Certifications and
Compliances:
EXD Series:
• NEC/CEC:
Class I, Division 1 & 2, Groups B†, C, D
Class I, Zone 1 & 2, IIB + H2†
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• NEMA/EEMAC: 3, 4, 4X‡, 7B†CD,
9EFG, 12
• CSA Enc. 3, 4, 5
• UL Standard: 67, 1203
• cUL (to CSA Standard C22.2
Nos. 29 & 30)
• IP65
D2D Series (Division 2):
• NEC/CEC:
Class I, Division 2, Groups B†, C, D
Class I, Zone 2, IIB + H2†
Class II, Division 2, Groups F, G
Class III
• NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
• CSA Enc. 3, 4, 5
• UL Standard: 67, 1203
• cUL (to CSA Standard C22.2
Nos. 29 & 30)
• IP65
1A
• Premium Solution: PowerPlus factorysealed panelboards are premium
panelboards that provide maximum
circuit flexibility with labor savings during
installation, operation, and maintenance,
and are accommodating for future
changes in the field (order with either “S”
or “A” in base part number). Panels are
pre-wired to maximum circuit capacity,
allowing for easy and safe replacement
or installation of components in the field,
while maintaining factory-sealed integrity.
• Value Solution: PowerPlus non-factorysealed panelboards are value
panelboards that offer maximum circuit
flexibility and many of the same features
and benefits of the PowerPlus premium
line. This value solution is provided
without terminal housing and factory
wiring of circuits (order with “N” in base
part number). The non-factory-sealed
solution reduces initial panelboard
material costs and requires field wiring to
circuit breakers and external seals to be
field-installed during installation.
D2D Series:
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Zone 2, IIB + H2†
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
Standard Materials and
Finishes:
• Circuit breaker enclosure body and
cover – copper-free aluminum
• Terminal housing – type 316L stainless
steel ("S") or copper-free aluminum ("A")
• Gasket – neoprene (cast aluminum
enclosure); foam-in-place (stainless steel
enclosure)
• Operating handles – copper-free
aluminum
• Operating shafts and bushings, cover
bolts, washers, hinges, breather/drain,
retractile springs – stainless steel
• Circuit breaker operators – EXD/D2D
Size F: copper-free aluminum; all other
types: non-metallic
• Lifting bracket – electrogalvanized cold
rolled steel
• Chassis – silver-plated copper
• Breather cap – Delrin® non-metallic
material
• Neutral and ground bar – tin-plated
aluminum
†Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers.
To order with brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for Sizes B, C, and D separately.
‡NEMA 4X rating is available when ordered with suffix S752 or S753.
Delrin® is a registered trademark of DuPont.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
641
1A
PowerPlus™ Panelboards
1A
Power
EXD Series (Div. 1 & 2)
D2D Series (Div. 2)
D2D Series:
EXD Series:
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Zone 2, IIB + H2†
Cl. I, Zone 1 & 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. II, Div. 2, Groups F, G
Cl. III
Cl. III
NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12
† Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers.
To order with brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for sizes B, C and D separately.
‡ NEMA 4X rating is available when ordered with suffix S752 or S753.
642
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
PowerPlus™ Panelboards
Power
EXD Series (Div. 1 & 2)
D2D Series (Div. 2)
EXD Series:
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Zone 1 & 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12
D2D Series:
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Zone 2, IIB + H2†
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
1A
1A
† Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers.
To order with brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for sizes B, C and D separately.
‡ NEMA 4X rating is available when ordered with suffix S752 or S753.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
643
1A PowerPlus™ Panelboards
Power
EXD Series (Div. 1 & 2)
D2D Series (Div. 2)
EXD Series:
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Zone 1 & 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12
Electrical Ratings:
Options:
Branch Breakers Trip Ratings:
To add the following features to the panelboard, add a dash and
then the suffix to the Cat. No. When multiple suffixes are needed,
add them to the Cat. No. in alpha-numeric order.
Panel
Size
B
C
D
F
Voltage
480Y/277
480Δ
480Y/277
480Δ
480Y/277
480Δ
480Y/277,
480Δ, or
600Δ††
Phase /
Wire
3P 4W
3P 3W
3P 4W
3P 3W
3P 4W
3P 3W
3P 3W or
3P 4W
Main Breaker
Amperage
Up to 100
Up to 100
Up to 100
Up to 100
Up to 225
Up to 225
Up to 225
Branch Breaker
G-frame
G-frame
G-frame
G-frame
G-frame
G-frame
F-frame
Panel Sizes B, C, and D (G-Frame CutlerHammer™):
1A
D2D Series:
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Zone 2, IIB + H2†
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
• 1-, 2-, and 3-pole: GHB 480/277Y (standard offering)
• 2- and 3-pole: GDB 480Δ (requires suffix -GDB)
• 1-, 2-, and 3-pole GBH 600Y/347 (requires suffix -GBH; contact
factory)
• 15, 20, 25, 30, 35, 40, 45, 50 amp (available in all breaker spaces
in panel), 60, 70, 80, 90, 100 amp (only 3 breaker spaces
available)‡‡
• Ambient compensated breakers are optional to +50°C (suffix V)
Panel Size F (F-frame breaker: EHD CutlerHammer™ standard):
• 15, 20, 25, 30, 35, 40, 45, 50, 60, 70 amp (available in all breaker
spaces in panel), 80, 90, 100 amp (only 3 breaker spaces
available)
• Breaker types available†††
- FDB: 2-, and 3-pole 600V
- FD: 1-, 2- (277V), and 3-pole (600V)
- HFD: 1-, 2- (277V), and 3-pole (600V)
- EHD: 1-, 2- (277V), and 3-pole (480V)
Description
Suffix
Space heater ............................................................................
R44
Square head plugs on all conduit openings• ..........................
SP
Epoxy powder coat finish, external .........................................
S752
Epoxy powder coat finish, internal and external .....................
S753
Recess head plugs on all conduit openings• ..........................
RP
Stainless steel breaker operator cover (ice shield) ..................
HG
Group B kit factory installed ....................................................
GB
GFI breakers✪ .........................................................................
G
EPD breakers✪ ........................................................................
E
HID breakers✪ .........................................................................
H
Ambient compensated breakers (50ºC) ..................................
V
GDB 480Δ 3P 3W system■ ....................................................
GDB
FDB 600V breakers* ................................................................ FDB600
FD 600V breakers* ................................................................... FD600
HFD 600V breakers* ................................................................ HFD600
Lamacoid Nameplate ...............................................................
LID
A standard panelboard has conduit openings for power
and branch circuits on top.
To order a panelboard with main power feed from the
bottom of breaker housing, and branch entries on top
(alternate) ..................................................................................... -A**
To order an inverted panelboard with all conduit openings for
power and branch circuits on the bottom (inverted) ...................
To order an inverted panelboard with main power feed on
top and bottom (alternate inverted) ............................................. -A-I**
Main Breaker Trip Ratings:
• 2- and 3-pole (contact factory for single phase sizes B, C, D)
• Size B, C: 15 to 100 amps
• Size D, F: 15 to 225 amps
Main Lugs:
• Size B, C, and F: 225 amps
• Size D: not available; main breaker only
Ampere Interrupting Capacity:
• All size panels are certified to 10kAIC
• Breaker AIC Ratings:
- GHB Breaker: 14kAIC at 480Y/277
- EHD Breaker: 14kAIC at 480V
Breaker types optional with Sizes B, C, and D panel only:
- GDB Breaker: 14kAIC at 480V
Breaker types optional with Size F panel only:
- FDB Breaker: 14kAIC at 480V and 600V
- FD Breaker: 18kAIC at 600V and 35kAIC at 480V & 277V
- HFD Breaker: 25kAIC at 600V and 65kAIC at 480V & 277V
†Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with
brackets installed at factory, add suffix –GB. For field installable kit, order EXD-GB-KIT for Sizes B, C, and D separately.
‡NEMA 4X rating is available when ordered with suffix S752 or S753.
††For 480Δ 3P 3W system or for 600VAC, a suffix is required. Note: for single-pole 480Δ, GHB breakers will be furnished for Sizes B, C, and D.
‡‡Two-pole GDB breakers are only available up to 50 amps.
†††F-frame breakers are only available in Size F panel with up to a maximum of 30 circuit spaces.
✪Please contact factory. Single pole 480V EPD available. For all others, please contact factory. Two breaker positions for single pole EPD: odds start at position 1; evens start at position 4.
■Available in D2D and EXD Sizes B, C, and D only.
*Available with D2D and EXD Size F panels only.
**D2D/EXD Sizes C and D are only available with up to 36 circuits.
•Not available on stainless terminal housings.
644
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
-I
Copyright© 2013 Eaton’s Crouse-Hinds Business
PowerPlus™ Panelboards
Power
EXD Series (Div. 1 & 2)
D2D Series (Div. 2)
EXD Series:
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Zone 1 & 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12
D2D Series:
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Zone 2, IIB + H2†
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
Accessories:
Terminal Housing Mounting Plate Kit:
Gland Plates
To adapt depth of terminal housing to same
depth as breaker enclosure ***
Panel Types / Sizes
Part Number
D2D/EXD Sizes B, C, D
EXDA-MTG-KIT
D2D Sizes B, C, D
D2DS-MTG-KIT
Field installable gland plates with factory-provided aluminum
Myers™ Hubs for the D2D stainless steel terminal housing (one 3inch hub and 12 branch entry hubs - size dependent upon suffix,
each kit includes 3 gland plates, 1 for the top or bottom and 1 for
each side):
Part Number
3
/4" branch entry hub
D2D HUB2 KIT
1" branch entry hub
D2D HUB3 KIT
1 1/2" branch entry hub
D2D HUB5 KIT
Replacement gland plate (no hubs)
D2D HUB0 KIT
1A
Terminal Housing
Aluminum
Stainless
Circuit Breaker Operator Assemblies:
Operator Assemblies
D2D/EXD All breakers panel Sizes B, C, D
D2D/EXD All breakers panel Sizes F
Part Number
EXD HDL123
EXD K1
Replacement Cover Plugs:
For unused circuit breaker positions (qty. 5):
Plug Kits
D2D/EXD Sizes B, C, D
D2D/EXD Size F
Part Number
EXD OP PLG
EXD K2
1A
Kit for Group B
Standard panels less -GB suffix are applicable for Group B, but it is
required to install brackets on breakers.
Part Number
To order brackets factory installed
add suffix -GB
For field installable kit (Sizes B, C, D)
EXD GB KIT
D2D/EXD Stainless Steel Breaker Operator Cover
To protect operators from ice build-up for all D2D/EXD
PowerPlus panels:
D2D/EXD PowerPlus panels
Part Number
Contact Factory
Space Heater Kit
D2D/EXD PowerPlus panels
EXD R44 KIT
†Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers.
To order with brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for Sizes B, C, and D separately.
*** The weight of the panel is sufficiently supported by mounting of breaker enclosure.
‡NEMA 4X rating is available when ordered with suffix S752 or S753.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
645
1A
PowerPlus™ Panelboards
Power
EXD Series (Div. 1 & 2)
D2D Series (Div. 2)
D2D Series:
EXD Series:
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Zone 1 & 2, IIB + H2†
Cl. I, Zone 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. II, Div. 2, Groups F, G
Cl. III
Cl. III
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12 NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
Table A – Panel Capacity
Maximum Number of Breaker Spaces:
Max. No. of Branch Circuit Breaker Spaces
Panel
With Main
With Main Breaker
Size
Lug Only
2-pole*
3-pole
Available Main
Breaker
Ampacity
Available
With GFI, EPD
Branch Protection***
B
C
D
F
Up
Up
Up
Up
No
No
No
No
24
42
N/A
30
22
40
42
30
21
39
42
30
to
to
to
to
100■
100■
225✪
225✪
Table B – To Size Panels with GFI or EPD
Branch Breakers
Maximum Number of GFI or EPD Breakers
Panel Size
with Main Lug SingleTwoor Main Breaker Pole
Pole
B
1A
C
D
12
(10 with 3-pole MCB,
11 with 2-pole MCB)
21
14
EPLDN only - can go up to 42 GFI or EPD
circuits. EPLDN will accommodate up to 225
amp main breaker.
21
Each factory-sealed panel is equipped with 42 load wires for
GFI/EPD breakers and any combination with standard branch
breakers. Determine the total number of load wires required to
complete your panel. You may not exceed 42 load wires.
Load Wires Required
Single-pole breaker
1
Single-pole GFI (or EPD) breaker
2
Two-pole breaker
2
Two-pole GFI (or EPD) breaker
3
Three-pole breaker
3
Maximum Total: 42 load wires
(factory sealed)
Maximum Total: 82 load wires
EPLDN Panels
(non-factory sealed)
† Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers. To order with
brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for Sizes B, C and D separately.
‡ NEMA 4X rating is available when ordered with suffix S752 or S753.
* Contact factory for single phase size B, C, or D.
✪ Main breakers are mounted external to chassis.
■ Main breakers are chassis mounted and back-fed.
***GFI, EPD for D2D/EXD are not standard options. If required, please contact factory. Single pole 480V EPD available. For all others, please contact factory. Two breaker positions for
single pole EPD: odds start at position 1; evens start at position 4.
646
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
PowerPlus™ Panelboards
Power
EXD Series (Div. 1 & 2)
D2D Series (Div. 2)
EXD Series:
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Zone 1 & 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12
1A
D2D Series:
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Zone 2, IIB + H2†
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
Power Panelboard Catalog Number Example
Example:
Class I, Division 2 / Zone 2, Group B panel with:
• 480ΔVAC power panelboard with 3-phase, 3-wire
• (42) single-pole 20 amp branch breakers
• 225 amp 3-pole main circuit breaker
1A
† Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers.
To order with brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for sizes B, C and D separately.
‡ NEMA 4X rating is available when ordered with suffix S752 or S753.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
647
1A
EXD Series:
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Zone 1 & 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12
PowerPlus™ Panelboards
Power
EXD Series (Div. 1 & 2)
D2D Series (Div. 2)
D2D Series:
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Zone 2, IIB + H2†
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC: 3, 4, 4X‡,
7B†CD, 12
Dimensions
Size B Panel*
(With Stainless Steel Terminal Housing)
20.12
[511.2]
1.83
[46.5]
11.16
[283.4]
4.00
[101.5]
11.37
[288.9]
APPROXIMATE
48.36
[1228.3]
3 1/2" NPT
ALTERNATE FEED OPTION
(SUFFIX 'A') ONLY
1A
17.25
[438.2]
6.17
[156.7]
21.88
[555.6]
Size C and D Panel*
(With Cast Aluminum Terminal Housing)
6.50
4.66 [165.1]
2.81 [118.4]
71.4
1-1/2" NPT
12 PLACES
6.50
[165.1]
4.66
[118.4]
2.81
71.4
3.51
[89.2]
TYP.
5.10
[129.5]
TYP.
.92
[23.4]
3 1/2" NPT
1.31
[33.3]
5.50
[139.7]
.50
[12.7]
13.49
[342.7]
APPROXIMATE
62.15
[1578.5]
28.25
[717.6]
6.82
[173.3]
21.88
[555.6]
† Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers.
To order with brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for sizes B, C and D separately.
‡ NEMA 4X rating is available when ordered with suffix S752 or S753.
*Stainless steel and cast aluminum terminal housing for sizes B, C, and D panels have same dimensions.
Note: Value series non-factory-sealed EXD*N panel dimensions are the breaker housing only and use standard entries shown on cast terminal housing.
648
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
PowerPlus™ Panelboards
Power
EXD Series (Div. 1 & 2)
D2D Series (Div. 2)
EXD Series:
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. I, Zone 1 & 2, IIB + H2†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC 3, 4, 4X‡, 7B†CD, 9EFG, 12
D2D Series:
Cl. I, Div. 2, Groups B†, C, D
Cl. I, Zone 2, IIB + H2†
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA/EEMAC: 3, 4, 4X‡, 7B†CD, 12
1A
Size F Panel
1A
† Group B and IIB + H2 is standard on all PowerPlus panels, but requires special brackets to be installed on breakers to ensure long-term operability of circuit breakers.
To order with brackets installed at factory, add suffix -GB. For field installable kit, order EXD-GB-KIT for sizes B, C and D separately.
‡ NEMA 4X rating is available when ordered with suffix S752 or S753.
*Stainless steel and cast aluminum terminal housing for sizes B, C, and D panels have same dimensions.
Note: Value series non-factory-sealed EXD*N panel dimensions are the breaker housing only and use standard entries shown on cast terminal housing.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
649
1A
Cl. I, Zone 1, Aex de IIC T4
Ex de IIC T4
Cl. I, Div. 2, Groups A, B, C, D
Cl. II, Div. 1, Groups E, F, G, Extb IIIC
T100°C Db
SynergEX Panelboards
Power, lighting, and heat tracing
panels for Class I, Division 2
applications
Type 4X, IP66
SynergEX Panelboards offer superior solutions utilizing individually
encapsulated circuit breakers to provide maximum safety in the most
extreme environments. The finger safe design provides ultimate
flexibility and speed during installation, normal operations and
maintenance activities in the field. This advanced design is
approved for all hazardous gases, which allows for operation in
multiple locations and hazardous situations.
Applications:
SynergEX Panelboards provide overcurrent and short circuit
protection for low voltage power, lighting, and heat tracing
applications in indoor and outdoor hazardous areas, such as:
• Refineries
• Chemical and petrochemical plants
• Mining
• Corrosive process facilities
• Food processing facilities
• Indoor and outdoor industrial applications
1A
Features:
•
•
•
•
•
•
•
•
•
Lightweight design for reduced labor and equipment installation
Dead-front design allows for operating breakers without hot permit
Finger safe design eliminates safety risk for personnel
Patented friction welded encapsulated molded-case circuit
breakers
Robust design providing operations in all gas groups and extreme
hot/cold environments
Front viewing window for easy visual indication of breaker status
Quick snap encapsulated circuit breakers (no bolts or screws)
Removable gland plates for easy addition of entries
Gangable for main breaker housing
Certifications and Compliances:
NEC/CEC:
• Class I, Zone 1, Aex de IIC T4
• Ex de IIC T4
• Class I, Division 2, Groups A, B, C, D
• Class II, Division 1, Groups E, F, G, Extb IIIC T100°C Db
• Type 4X, IP66
Electrical Ratings:
SynergEX Panelboard:
• Max. 225A / Phase (3 phase max.)
• Max. 480VAC
• Max. 225A main breaker (external enclosure)
• 10kA short circuit current
Encapsulated Circuit Breakers:
• 480/277VAC
- 1-, 2- and 3-pole
- 10, 15, 20, 25, 30, 35, 40 amps
- Auxiliary and signal contact
• 240/120VAC
- 1-, 2- and 3-pole
- 10, 15, 20, 25, 30, 35, 40 amps
- 1-pole GFI and EPD
- Auxiliary and signal contact
Standard Materials:
• Enclosure – 316L stainless steel or painted steel
• Observation window – laminated safety glass
• External parts (hinges, screws, washers, 1/4 turn locks, gland
plates) – 316L stainless steel
• Internal parts (screws, washers, back plate, fasteners) –
304 stainless steel
• Gasket – silicone
• Dead-front panel – flame rated fiberboard (V-1)
• Bus bars – nickel-plated copper
• Filler plates – flame rated nylon (V-0)
• Bonding/grounding assembly – brass
• Encapsulated circuit breakers – flame rated nylon (V-2)
Options:
Description
Breather and Drain
Main Breaker (100A, 150A, 225A)
Heater (-40°C)
Bottom Feed Inverted Panelboard
Gland Plates (see locations below)
Top View
6
5
3
8
Left View
Right View
4
7
1
2
Bottom View
650
www.crouse-hinds.com
US: 1-866-764-5454
Suffix
BD
See Catalog
Numbering System
HTR
I
GP1-GP8
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
SynergEX Panelboards
Cl. I, Zone 1, Aex de IIC T4
Ex de IIC T4
Cl. I, Div. 2, Groups A, B, C, D
Cl. II, Div. 1, Groups E, F, G, Extb IIIC
T100°C Db
Power, lighting, and heat tracing
panels for Class I, Division 2
applications
Type 4X, IP66
1A
A
D
C
1A
B
E
A
Extreme temperature durability - This panelboard is designed to withstand temperatures ranging from -40°C to +55°C, offering operational
durability in the most extreme environments.
B
Efficient breaker operation - Dead front design allows for breakers to be easily and quickly reset.
C
Certified for all hazardous gases - The individually encapsulated breakers are certified for all hazardous gases (ABCD, IIC), allowing an end-user
to install the product in a variety of hazardous locations.
D
Finger safe configuration - Enhanced finger safe design prevents contact with live parts, ensuring personnel safety.
E
Quick snap, screwless breaker replacement - Our circuit breakers are individually encapsulated without any bolts or screws, greatly reducing
installation time and cost.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
651
1A
Cl. I, Zone 1, Aex de IIC T4
Ex de IIC T4
Cl. I, Div. 2, Groups A, B, C, D
Cl. II, Div. 1, Groups E, F, G, Extb IIIC
T100°C Db
SynergEX Panelboards
Power, lighting, and heat tracing
panels for Class I, Division 2
applications
Type 4X, IP66
Catalog Numbering System:
SERIES
SIZE
MATERIAL
PANEL
PHASE
PANEL
VOLTAGE
RATING
BREAKER
SPACES
ASTERISK
QUANTITY
OF ALIKE
BRANCH
BREAKERS
BRANCH
BREAKER
POLE
RATING
BRANCH
BREAKER
AMPERE
RATING
DASH
MAIN
BREAKER
DASH
OPTIONS
GLAND
PLATES
SPB
A
S
1
1
12
*
12
1
10
-
3M100
-
HTR
GP1GP2GP3
Series
SPB
Enclosure Size
A = 12 CCT
B = 24 CCT
C = 42 CCT
D = 60 CCT
Enclosure Material Type
S = 316L Stainless Steel (Type 4X)
P = 304 Painted Steel (Type 4X)
1A
Panel Phase
1 = Single Phase
3 = Three Phase
Panel Voltage Rating
1 = 120/240V (1 Phase, 3 Wire)
2 = 208/120V (3 Phase, 4 Wire)
4 = 480/277V (3 Phase, 4 Wire)
Breaker Spaces
1P Breaker = 1 Space TOTAL NUMBER OF BREAKER SPACES UTILIZED
2P Breaker = 2 Spaces ROUND UP TO AN EVEN NUMBER
3P Breaker = 3 Spaces
Insert Asterisk (*) Before Each Branch Breaker Series
Quantity of Alike Branch Breakers
Branch Breaker Pole Rating
1 = 1P Breaker
1AX = 1P Breaker + Auxiliary
1SC = 1P Breaker + Signal Contact
2 = 2P Breaker
2AX = 2P Breaker + Auxiliary
2SC = 2P Breaker + Signal Contact
3 = 3P Breaker
3AX = 3P Breaker + Auxiliary
3SC = 3P Breaker + Signal Contact
1G = 1P GFI
1E = 1P EPD
Branch Breaker Ampere Rating
Example: 20 = 20A NUMERICAL VALUE REPRESENTS AMPERE RATING
Dash Indicates Main Breaker to Follow
Main Breaker
2- or 3-pole, 15 to 225A (Example: 3M100 - 3-pole main breaker, 100A)
Note: Breakers above 40A to be housed in separate enclosure
Dash Indicates Options to Follow
Option Suffixes (see page 4 for available options)
Gland Plates
652
Gland plates at locations 1, 2 and 3 are standard
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
SynergEX Panelboards
Cl. I, Zone 1, Aex de IIC T4
Ex de IIC T4
Cl. I, Div. 2, Groups A, B, C, D
Cl. II, Div. 1, Groups E, F, G, Extb IIIC
T100°C Db
Power, lighting, and heat tracing
panels for Class I, Division 2
applications
1A
Type 4X, IP66
Dimensions:
12 Circuits
11.81”
(300mm)
11.81”
(300mm)
24 Circuits
37.40”
(950mm)
30.51”
(775mm)
1A
43.31”
(1100mm)
37.40”
(950mm)
60 Circuits
11.81”
(300mm)
11.81”
(300mm)
42 Circuits
37.40”
(950mm)
www.crouse-hinds.com
US: 1-866-764-5454
50.39”
(1280mm)
62.99”
(1600mm)
74.80”
(1900mm)
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
653
1A
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 1, Group IIC
Cl. II, Div. 1, Groups E, F, G
D2Z Panelboards
Zone 1, Division 2
AEx de II C T4, T6
Ex de IIC T4, T6
NEMA 4X, IP65
Non-metallic or Stainless Steel
Applications:
D2Z panelboards are designed specifically for use in:
• Class I, Zone 1, Division 2, Groups A, B, C, D hazardous area
locations.
• In damp, wet or corrosive locations.
• Indoors or outdoors in Zone 1, Division 2 areas of petroleum
refineries, chemical and petrochemical plants, and other process
industry facilities.
1A
Features:
• cCSAus, PTB* certified for Class I, Zone 1, Division 2 hazardous
areas.
• Fiberglass-reinforced polyester enclosures:
Non-metallic, corrosion-free
Increased safety Ex-e protection
Impact resistant
NEMA 4X, IP65
Enclosure meets UL 94-VO
UV listed
• 316L stainless steel enclosures (suffix S860):
Corrosion resistant
Industrial grade thickness
NEMA 4X, IP65
• Unique design allows for panels with more than 42 circuits.
• Main disconnect switches 40, 80, 125, 180A.
• Optional flameproof Ex-d fusing of main disconnect.
• Flameproof Ex-d encapsulated UL 489 branch circuit breakers:
Thermal-magnetic protection up to 40A with 240 VAC circuit
breakers.
Thermal-magnetic protection up to 25A with 480 VAC circuit
breakers.
Auxiliary contacts (mechanical or electrical).**
Lockout on components.
Prewired to Increase Safety terminal blocks.
GFI branch breakers (EPDs).**
• Clear, NEMA 4X / IP65 window, hinged for actuation or breakers.
• Double lockout on windows and breakers.
• Brass plates for hub or cable gland entries.
• Enclosures are to be vertically mounted on switchrack frames or
walls.
• Completely pre-wired ready for connection to terminal blocks.
D2Z with fiberglass-reinforced polyester enclosure
Certifications and Compliances*:
Certifications
Degree of Protection
cCSAus
NEMA 4X
IP65 to IEC 60529
ISO 4892
Glass-reinforced polyester
-55°C to 40°C***
480 VAC
Max. 180A
UV Resistance
Enclosure Material
Temperature Ratings
Rated Voltage
Rated Current
• NEC:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 1, Group IIC
• CEC:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 1, Group IIC
Class II, Division 1, Groups E, F, G
• UL Standards:
UL60079-0
UL60079-1
UL60079-7
UL60079-18
• CSA Standards:
C22.2 E60079-0-02
C22.2 E60079-1-02
C22.2 E60079-7-2003
C22.2 E60079-18-95
654
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
D2Z with 316L stainless steel enclosure (suffix S860)
Options:
The following special options are available from the factory by
adding the suffix to the Cat. #:
Description
Suffix
D2Z Series panelboards are now available with 316L stainless
steel enclosures. This material is ideal for wash down and
corrosive areas requiring product endurance in adverse
locations.
S860
*Available with ATEX certification, please consult factory.
**Available with only UL 1077 supplemental protectors.
***For ambients -20ºC or less, optional heater is required.
Copyright© 2013 Eaton’s Crouse-Hinds Business
D2Z Panelboards
Zone 1, Division 2
AEx de II C T4, T6
Ex de IIC T4, T6
NEMA 4X, IP65
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 1, Group IIC
Cl. II, Div. 1, Groups E, F, G
1A
Non-metallic or Stainless Steel
Technical Data
Branch Circuit Breakers
1-pole, 2-pole, 3-pole, 4-pole; with EPD protection 1-pole + Neutral,
2-pole; 2, 6, 10, 16, 20, 25, 32 and 40 Amps
Explosion Protection
Certifications
Rated Operating Voltage
Rated Current
Rated Switching Capacity
Circuit Breaker Characteristics
Tripping Characteristics
Tripping Current for EPDs
Circuit Breaker Enclosure Materials
Optional Auxiliary/Signal Contacts**
Rated Voltage
Rated Current
250 VAC
5A
Main Disconnect Switch
1A
• Large windows permit easy viewing and
quick access to breakers without
opening the enclosures.
• Lockouts standard for both windows
and breakers
• Up to 6 single-pole breakers can be
installed under one window.
• NEMA 4X, IP65 protection.
• Window locks with 5/16" (8mm) Allen Key.
Ex de IIC
AEx de IIC
Class I, Zone 1, Div. 2, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G
cCSAus
Up to max. 480 VAC
Up to 40A
10k AlC
UL489 Circuit Breakers
"Z" or "K"*
30mA (up to 300mA on request)
Fiberglass-reinforced epoxy
40, 80, 125, 180A, 4-pole
Explosion Protection
Ex de IIC T6
AEx de IIC T6
Class I, Zone 1, Div. 2, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G
Rated Operating Voltage
Up to 690 VAC
Motor Switching Capacity AC3***
Type
40A
80A
125A
180A
230V
40A
80A
125A
180A
400V
40A
80A
125A
180A
500V
40A
80A
125A
150A
690V
32A
63A
110A
125A
Main Switch
• 40A main switch, 4-pole, optional fusing
in enclosure with window(s).
• 80, 125 and 180A main switch, 4-pole,
optional fusing in enclosure.
***See IEC 60947-3.
* "Z" Branch breakers are used for all general applications such as lighting and heat tracing.
Type "K" breakers are used for MOVs and portable power. Contact factory for other application.
** Aux contacts indicate mechanical or electrical tripping
Signal contacts indicate only electrical tripping and are used primarily on heat-tracing circuits.
Branch breakers with signal contacts require next larger breaker enclosure.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
655
D2Z Panelboards
Zone 1, Division 2
1A
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 1, Group IIC
Cl. II, Div. 1, Groups E, F, G
AEx de IIC T4, T6
Ex de IIC T4, T6
NEMA 4X, IP65
Non-metallic or Stainless Steel
Main Fuse, 3-pole
Explosion Protection
Ex de IIC
AEx de IIC
Class I, Zone 1, Div. 2, Groups A, B, C, D
Rated Operating Voltage
Up to max. 500 VAC
Rated Current
Current
Temperature Class in Board
25A
T6
35A
T5
50A
T4
63A
T4
80A
T4
100A
T4
125A
T4
Recommended manufacturer: Eaton's Bussmann type NH00G fuses for general use
or N00M for motor applications.
Specify Amperage (Fuses not provided)
Main Fuse, type NH
Standard Entries
Metric Entries
(remove hubs)
(1) 2" + (3) 1"
(9) 3/4"
(1) M63 + (3) M32
(9) M25
1A
Main supply
Branches
Brass gland plate
with Zone 1 Myers
adapter hubs: (STM series)
• Universal Wiring – Zone 1 Myers™
adapter hubs for conduit or Terminator™
cable glands.
• Stainless Steel Hubs – available upon
request.
656
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
D2Z Panelboards
Zone 1, Division 2
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 1, Group IIC
Cl. II, Div. 1, Groups E, F, G
AEx de II C T4, T6
Ex de IIC T4, T6
NEMA 4X, IP65
1A
Non-metallic or Stainless Steel
SpecOne™ D2Z Panelboard Construction Layout
Example of D2Z distribution panel with built-in components under
the window. (available mounting width = 213mm)
1A
D2Z panel with 3 mounting spaces
1
2
3
4
5
6
7
8
9
10
Mounting Space – 190mm
Mounting Space – 190mm
Mounting Space – 190mm
(2) 4 pole breakers – width 106mm each (available mounting width – 213mm)
(3) 3 pole breakers – width 70mm each (available mounting width – 213mm)
(4) 2 pole breakers – width 53mm each (available mounting width – 213mm)
(6) 1 pole breakers – width 35mm each (available mounting width – 213mm)
40A main switch, 4-pole. 1 mounting space required
Main fuse. 1 mounting space required in place of 1 window
Window
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
657
1A
D2Z Panelboards
Zone 1, Division 2
AEx de II C T4, T6
Ex de IIC T4, T6
NEMA 4X, IP65
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 1, Group IIC
Cl. II, Div. 1, Groups E, F, G
Non-metallic or Stainless Steel
Ordering Procedure
Step 1: Window
Determine the number of windows required from the following chart based on the number of branch breakers. Multiply breaker space by
number of breakers. Round the sum total to the next highest whole number to determine required windows. i.e. For (8) 1-pole and (2) 2-pole
breakers: (8 x 0.16) + (2 x 0.25) = 1.78 = 2 windows required.
Max. No.
Per Window
Branch Circuit
Breakers (max 40A)
Space Required
For Each Breaker
1-pole
.16
4
2-pole
or
1-pole with EPD
or
1-pole with signal contact
.25
3
3-pole
or
1-pole + Neutral with signal contact
or
2-pole with signal contact
.33
2
4-pole
or
2-pole with EPD
or
3-pole with signal contact
.50
1A
6
Step 2: Disconnect Switch
If a disconnect switch is required, select suffix from table.
Main Switch Disconnect
40
80
125
180
3-phase
–3S* 40
–3S* 80
–3S* 125
–3S 180
Single Phase
–2S* 40
–2S* 80
–2S* 125
—
*Add F if fuses required. Fuses supplied by others. See page 656
658
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
D2Z Panelboards
Zone 1, Division 2
1A
AEx de II C T4, T6
Ex de IIC T4, T6
NEMA 4X, IP65
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 1, Group IIC
Cl. II, Div. 1, Groups E, F, G
Non-metallic or Stainless Steel
Step 3: Panel Size
Determine Panel Size Based on Windows Required
Number of Windows
Required
Type Required
Disconnect
1, 2
3
4–6
7–9
A mini panel
B panel
C panel
D panel
40A disconnect – Integral
Optional – Adjacent
Optional – Adjacent
Optional – Adjacent
Type A Mini Panels with Main Switch
40A 3-Phase
40A Fused 3-Phase
D2Z
D2Z
D2Z
D2Z
D2Z A306 - 3SF40*
A306
A308
A310
A312
-
3S40*
3S40*
3S40*
3S40*
Single Phase
D2Z
D2Z
D2Z
D2Z
D2Z A106 - 2SF40*
A106
A108
A110
A112
-
2S40*
2S40*
2S40*
2S40*
6
8
10
12
Quantity of
Single Circuits
6
8
10
12
1A
Single Phase
Quantity of
Single Circuits
*See page 661 to complete catalog number.
Panels Type B, C, and D
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
659
1A
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 1, Group IIC
Cl. II, Div. 1, Groups E, F, G
D2Z Panelboards
Zone 1, Division 2
AEx de II C T4, T6
Ex de IIC T4, T6
NEMA 4X, IP65
Non-metallic or Stainless Steel
Step 4: Conduit/Cable Entries
Determine if additional entries are required on sides B and C. All panels are supplied with bottom entries (Side A), 1 main supply and
remainder as branches.
Example: Size D panels with disconnect switch have 1 main supply and 3 branch plates as standard.
Main Entries
Entries
Location
Main Supply
(1) 2" + (3) 1"
A (Standard)
Branches
(9) 3/4" (B panel)
(18) 3/4" (C panel)
(27) 3/4" (D panel)
A (Standard)
A (Standard)
A (Standard)
Branches
(9) 3/4"
(9) 3/4"
B (Optional) left side
C (Optional) left side
1A
Type
Terminal Wiring
Supply Circuits
Amperage
mm2
AWG
Branch Circuits
Amperage
mm2
AWG
40
80
125
180
16
35
70
95
6-18
2-6
8-2/0
6-3/0
10
15
20
40
4
4
10
16
12-22
12-22
6-14
6-18
660
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 1, Group IIC
Cl. II, Div. 1, Groups E, F, G
D2Z Panelboards
Zone 1, Division 2
AEx de II C T4, T6
Ex de IIC T4, T6
NEMA 4X, IP65
1A
Non-metallic or Stainless Steel
How to Build a Catalog Number‡
1A
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
661
D2Z Panelboards
Zone 1, Division 2
1A
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 1, Group IIC
Cl. II, Div. 1, Groups E, F, G
AEx de II C T4, T6
Ex de IIC T4, T6
NEMA 4X, IP65
Non-metallic or Stainless Steel
Please state rated current on order:
2, 6, 10, 16, 20, 25, 32 or 40A.*
Spare Component Information
Lighting Circuits Order Code
10k AIC, max. 480 VAC
1-pole
6/window
SIA 001
2-pole
4/window
SIA 002
Optional:
Auxiliary contact – SAH 001
Signal contact – SAS 001 (in the case of
branch breakers with
signal contacts, the next
largest component size is
used)
3-pole
3/window
SIA 003
4-pole
2/window
SIA 004
Heat-Tracing Order Code
EPD with 10k AIC, 30mA leakage, max. 480 VAC
Example:
SIA 001-20 – SAH001
Single Pole, 20A with auxiliary contacts
Please state rated current on order:
6, 10, 16, 20, 25, 32 or 40A.
1A
Optional:
With auxiliary contact – FSH 001
With signal contact in Size 4 component –
FSS001
Example:
FSS 004 - 30 – FSS001
EPD, 30A, 30mA with signal contact
1-pole + N
4/window
FSS 002
2-pole
2/window
FSS 004
*25 ampere max. for 480VAC breakers.
Dimensions
Used only for fuses on 80, 125 or 180A disconnect switches
Used only for fuses on 80, 125 or 180A disconnect switches without fuses.
Used for
– 40A switch with fuses and 1 window or
– 40A switch and 2 windows, or
– 3 windows of branch breakers.
Dimensions in mm X = mounting dimensions
662
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
D2PB Division 2 Circuit Breaker
Panelboards
Factory Sealed, Single & Two-Pole
Circuit Breakers
Applications:
Standard Materials:
D2PB panelboards are designed specifically
for use:
• In Class I, Division 2, Groups C, D
hazardous areas where flammable vapors
or gases may be present due to accident or
abnormal locations
• In damp, wet or corrosive locations
• Indoors or outdoors in Division 2 areas of
petroleum refineries, chemical and
petrochemical plants, and other process
industry facilities
For general application, circuit breaker and
wiring system information, see
pages 626–629.
• Bodies, covers and hinged doors –
copper-free aluminum
• Breaker operating handles – type 6 / 6
nylon
• Interior parts – sheet steel
Features:
Standard Finishes:
• Copper-free aluminum – natural
• Type 6 / 6 nylon – natural (black)
• Sheet steel – electrogalvanized with
chromate finish
Options:
Description:
Suffix:
• Panelboard provided with
operating handle lockouts for
lockout in ON or OFF positions.
Stainless steel lockout frame
integral to panel faceplate.
D2PB Size 1..................................... L12
D2PB Size 2..................................... L24
• Branch conduit entries furnished
with Eaton's Crouse-Hinds type
PLG plugs.......................................... S822
• Square head plugs in all openings.... S872
• Branch circuit conduit openings
located at bottom instead of at top.. INV
• Drilled and tapped conduit
openings other than standard –
available on special order – specify..
I
• Breather and drain............................ DV
• Circuit breaker operating handle
lockout - order D2PB02
• Assortment of single-pole and
two-pole circuit breakers and trip
ratings – see listings.
Wiring system other than those listed –
Specify
See page 628
Dimensions
1A
• Enclosures are of external flange design,
which makes the interior completely
accessible when the cover is removed
• Provided with concealed mounting, which is
made possible by having four clearance
holes for lag screws or mounting bolts in
the back of the enclosure, one in each
corner
• The interior sub-assembly, consisting of a
mounting plate, main terminal blocks, and
circuit breakers, is removable as a complete
unit
• Ample gutter space is provided for ease of
field wiring
• Circuit breakers are contained in compact,
individual factory sealed enclosures suitable
for Class I, Division 2, Groups C, D
hazardous areas. The individual enclosures
are easily removed and replaced, therefore
changing or adding individual circuit
breakers will not present a problem
• The main cover, which is gasketed to
exclude dirt and moisture, is attached to the
body with hex head bolts and is removed
only when installing the panelboard or
making wiring changes. In the center of the
main cover is a gasketed hinged door,
which provides access only to the circuit
breaker operating handles, and is held
closed by two quick release catches. The
door can be locked by as many as 3
padlocks to prevent unauthorized operation
• Tapped conduit openings are provided for
main conduit and branch circuits, as shown
in the dimensional information. Standard
openings can be reduced or plugged to
meet most installation requirements
• Circuit breakers are arranged in two vertical
rows and have the circuit numbers marked
on the handles. The left row is numbered 1,
3, 5, 7, etc. and the right row 2, 4, 6, 8, etc.
Identifying information may be typed on the
circuit directory card attached to the inside
of the hinged door
1A
Wet Locations
Cl. I, Div. 2, Groups C, D
NEMA 3, 7CD (Div. 2), 12
Dust-tight
Raintight
Size Ranges:
Panel Size
Max. No. of Breakers
Single-Pole
Two-Pole
1
2
12
24
6
12
Electrical Rating Ranges:
•
•
•
•
Circuit breakers
Single-pole – 120/240VAC max.
Two-pole – 120/240VAC max.
Trip ratings – 15, 20 and 30 amp
In Inches:
Certifications and
Compliances:
• NEC:
Class I, Division 2, Groups C, D
• NEMA: 3, 7CD (Division 2), 12
• UL Standard: 67, 877
Dimensions are approximate, not for construction purposes.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
663
1A
D2PB Division 2 Circuit Breaker
Panelboards
Cl. I, Div. 2, Groups C, D
NEMA 3, 7CD (Div. 2), 12
Dust-tight
Raintight
Factory Sealed, Single & Two-Pole
Circuit Breakers
Wet Locations
D2CB12-20
Replacement Circuit
Breaker Assemblies
D2PB with Main Breaker Option
Where D2PB (and N2PB) panelboards have
been ordered with less than the maximum
number of circuit breakers, breakers can
easily be added in the field. Circuit breaker
assemblies for field addition or
replacement are listed below; they consist
of the breaker itself in its factory sealed
Class I, Division 2, Groups C, D enclosure,
and necessary mounting hardware. These
assemblies are not suitable for use as
individually mounted units.
Ordering Information:
1A
Panelboards are available with single-pole and two-pole, 15, 20, or 30 ampere circuit
breakers. To order a panelboard with all breakers of the same rating, add the desired rating
as a suffix to the Cat. No. For example, the 12 circuit D2PB1512 panelboard with all the
circuit breakers rated at 20 amperes would be ordered as D2PB1512-20.
Panelboards shown below can also be furnished with an assortment of single-pole and twopole breakers and breaker ampere ratings. To order, the quantities of breakers and ampere
ratings are added as a suffix to the Cat. No. The total number of poles will determine the
panel size (24 poles maximum), and the wiring systems must be compatible when
combining single- and two-pole circuit breakers. For example, a typical D2PB panelboard
with a combination of 3 single-pole 15 ampere, 3 single-pole 20 ampere, 2 single-pole 30
ampere, 4 two-pole 20 ampere, and 4 two-pole 30 ampere circuit breakers would be
ordered as D2PB2508-315-320-230-808-420-430. The total number of poles is 24 and
wiring systems 5 and 8 are compatible 4 wire, 3 phase.
The D2PB with a main breaker is available up to 100 amps. To order D2PB with main
breaker, add the appropriate suffix. Example: D2PB1512-15 with three-pole, 100 amp main
circuit breaker would be ordered as D2PB1512-15-3M100. If two-pole main is required,
change the number 3 to 2. If a lower trip rating than 100 is required, the suffix will change
accordingly.
Max. No. of
Breakers
SinglePole
TwoPole
Panel
Size
Main
Lug
Size‡
6
8
10
12
4
5
6
1
1/0
12
6
14
7
16
8
2
4/0
18
9
20
10
22
11
24
12
➀Add ampere rating. See ordering information.
Single-Pole Circuit Breakers
Wiring System 4*
Wiring System 5*
Mains: 3-Wire
Mains: 4-Wire, 3-Phase
Branches: 2-Wire
Branches: 2-Wire
Solid Neutral
Solid Neutral
Cat. #
Cat. #
Circuit Breaker Assemblies
Ampere
Rating
Single-Pole
Cat. #
Two-Pole
Cat. #
15
20
30
D2CB11 15
D2CB11 20
D2CB11 30
D2CB12 15
D2CB12 20
D2CB12 30
Two-Pole Circuit Breakers
Wiring System 3*
Wiring System 8*
Mains: 3-Wire
Mains: 4-Wire, 3-Phase
Branches: 3-Wire
Branches: 3-Wire, 1-Phase
Solid Neutral
Solid Neutral
Cat. #
Cat. #
D2PB1406
D2PB1408
D2PB1410
D2PB1412
➀
➀
➀
➀
D2PB1506
D2PB1508
D2PB1510
D2PB1512
➀
➀
➀
➀
D2PB1304 ➀
D2PB1305 ➀
D2PB1306 ➀
D2PB2412
D2PB2414
D2PB2416
D2PB2418
D2PB2420
D2PB2422
D2PB2424
➀
➀
➀
➀
➀
➀
➀
D2PB2512
D2PB2514
D2PB2516
D2PB2518
D2PB2520
D2PB2522
D2PB2524
➀
➀
➀
➀
➀
➀
➀
D2PB2306
D2PB2307
D2PB2308
D2PB2309
D2PB2310
D2PB2311
D2PB2312
D2PB1804 ➀
D2PB1805 ➀
D2PB1806 ➀
➀
➀
➀
➀
➀
➀
➀
D2PB2806
D2PB2807
D2PB2808
D2PB2809
D2PB2810
D2PB2811
D2PB2812
p
➀
➀
➀
➀
➀
➀
➀
‡1/0 lug, rated 125 amps. takes wire sizes #6 to 1/0; 4/0 lug, rated 225 amps. takes wires sizes 1/ 0 to 4/ 0.
*For description of these standard wiring systems, see page 628.
Dimensions
Overall and Mounting
Dimensions (In.)
a
b
c
Panel Size Without Main C.B.
1
203/4
8
16
2
113/4
231/2
281/4
Conduit Openings
Spacing (In.)
f
g
h
j
Size (In.)
k
m
n✪
73/4
113/8
3
3
11/4
11/4
11/4
11/4
11/4
11/4
Panel Size With Main C.B.
1
8
16
73/4
203/4
2
113/4
231/2
113/8
281/4
✪Conduit opening "n" not supplied on panel size 1.
664
www.crouse-hinds.com
US: 1-866-764-5454
31/2
31/16
2
115/16
115/16
5
5
115/16
115/16
115/16
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
21/2
21/2
Quantity
Main Branches
2
2
8
12
2
2
8
12
D2PB, D2L, D2D Circuit Breaker
Panelboard Assemblies
Cl. I, Div. 2, Groups B†, C, D
NEMA 3, 4‡, 7B†CD (Div. 2), 12
Wet Locations
Watertight‡
with Transformer
Applications:
Standard Materials:
D2PB, D2L, D2D circuit breaker
panelboard assemblies with transformers
are for use:
• In Class I, Division 2, Group C, D
hazardous areas where, due to accident
or abnormal operations, flammable
vapors or gases may be present, and
which are subject to weather, dampness
and corrosion
• Indoors or outdoors in Division 2 areas
such as petroleum refineries, chemical
and petrochemical plants, and other
process industry facilities
• Where high voltage supply must be
stepped down to the lower voltage
necessary to serve lighting, heating,
appliance, heat tracing, motor and
similar circuits
For general information on panelboard
applications, circuit breakers and wiring
systems, see pages 626–629.
• Frames – structural aluminum
• Mounting hardware – stainless steel
• Transformer enclosure – sheet steel,
welded
• For panelboard materials, see individual
listing pages
• The factory assembled panelboard and
transformer are on one compact frame,
suitable for either wall or pole mounting.
Wiring between the transformer
secondary and main lugs of the
panelboard is accomplished at the
factory.
• Easy to install and wire. The main feed is
connected to the transformer primary
and the branch circuits are wired to the
panelboard terminal blocks.
• The assembly can be installed in the
load area to reduce the length of runs of
low voltage branch circuits.
• Panelboards used are standard D2PB,
D2L, or D2D units with circuit breakers
listed in this section.
• Transformers are compound filled or
epoxy filled to completely seal out
moisture and dirt.
Standard Finishes:
•
•
•
•
Aluminum – natural
Stainless steel – natural
Sheet steel – primed and painted
For panelboard finishes, see individual
listing pages
Options:
• Material – structural steel frames
• Finish – primed and painted or hot dip
galvanized
• For options available on the panelboards
themselves, see individual listings pages
1A
Features:
1A
Size Ranges:
Transformers
Single or three-phase – 5kVA to 30kVA
Panelboards
Max. No. of Breakers
SingleTwopole
pole
D2PB
24
12
D2L
42
20
D2D
30
14
Threepole
14
10
Electrical Rating Ranges:
• Transformers – 480 volt primary
• Transformers – 120 / 240 volt secondary
• Panelboards – see individual listings
Certifications and
Compliances:
• NEC/CEC:
Class I, Division 2, Group B†, C, D
• NEMA/EEMAC: 3, 4‡, 7B†CD (Division 2),
12
• UL Standard: 67, 1604
• CSA Standard: C22.2 No. 213
† D2L, D2D with GB suffix and breather and drain holes plugged.
‡ NEMA 4 hosetight with breather and drain openings plugged.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
665
1A
D2PB, D2L, D2D Circuit Breaker
Panelboard Assemblies
with Transformer
Cl. I, Div. 2, Groups B†, C, D
NEMA 3, 4‡, 7B†CD (Div. 2), 12
Wet Locations
Watertight‡
Typical Assembly*
Ordering Check List
24 Circuit D2PB panelboard with single-phase
transformer
1. Select the D2PB, D2L, D2D panelboard required, together with
any applicable options or special features. See individual listing
pages.
Cat. No.
2. Provide the following information, necessary for selection of the
correct transformer:
Primary voltage
Secondary voltage
kVA rating
Taps – number and percent
Frequency (60 cycle unless otherwise specified)
Single or three-phase
1A
Other requirements
*Dimensions are approximate, not for construction purposes.
† D2L, D2D with GB suffix and breather and drain holes plugged.
‡ NEMA 4 hosetight with breather and drain openings plugged.
666
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
GUSC Circuit Breaker
Load Centers
with Quicklag® Circuit Breakers
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
1A
Applications:
GUSC circuit breaker load centers are
used in:
• Areas which are hazardous due to the
presence of flammable vapors, gases or
highly combustible dusts, and which are
subject to weather, dampness and
corrosion
• Indoors or outdoors at petroleum
refineries, chemical and petrochemical
plants and other process industry
facilities where similar hazards exist
For general application and circuit breaker
information, see pages 626–627.
Features:
Certifications and
Compliances:
Size Ranges:
Max. No. of Breakers
Single-pole
Two-pole
2
1
Electrical Rating Ranges:
1A
• Compact rectangular enclosures with
round threaded covers
• External operating handles can be
padlocked in either "ON" or "OFF"
positions
• Not furnished with internal wiring as field
wiring connections are made directly to
circuit breaker line and load terminals.
To meet varying grounding
requirements, an insulated neutral
terminal block is provided and is
equipped with a removable grounding
jumper
• Bodies have 1" vertical throughfeed
hubs
• Quicklag circuit breakers: single-pole,
240VAC max.; two-pole, 240VAC max.
• Trip ratings: 10, 15, 20, 30 and 40 amp.
Options:
The following special options are available from factory by adding suffix to Cat. No.:
Description
Suffix
• Breather and drain (Class I and Class II)................................................................... S198V
• Breather and drain (Class I and Class II, Groups F, G)............................................. S454V
• Assortment of single and two-pole circuit breakers and trip ratings........................ Specify
• NEC:
Class I, Div. 1 & 2, Groups B†, C, D
Class II, Div. 1, Groups E, F, G
Class II, Div. 2, Groups F, G
Class III
• NEMA: 3, 7BCD, 9EFG, 12
• UL Standard: 1203
Standard Materials:
• Bodies – Feraloy® iron alloy
• Covers and operating handles – copperfree aluminum
• Operating shafts – stainless steel
• Interior parts – sheet steel
Standard Finishes:
• Feraloy iron alloy – electrogalvanized
and aluminum acrylic paint
• Copper-free aluminum – natural
• Stainless steel – natural
• Sheet steel – electrogalvanized with
chromate finish
†See listings for catalog numbers which are suitable for use in Group B hazardous locations. Seals must be installed within 11/ 2" of all conduit openings.
Quicklag is a registered trademark of Cutler-Hammer Inc.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
667
1A
GUSC Circuit Breaker
Load Centers
Cl. I, Div. 1 & 2, Groups B†, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
with Quicklag® Circuit Breakers
Circuit Breaker Information
No. of Breakers
1
2
1
Load Center With Circuit Breaker
Poles
Ampere Rating
Hub Size
Standard Units Cat. #
Group B Units Cat. #
1
10
15
20
30
40
1
1
1
1
1
GUSC3110
GUSC3110
GUSC3110
GUSC3110
GUSC3110
10
15
20
30
40
GUSC3110
GUSC3110
GUSC3110
GUSC3110
GUSC3110
10
15
20
30
40
GB
GB
GB
GB
GB
1
10
15
20
30
40
1
1
1
1
1
GUSC3210
GUSC3210
GUSC3210
GUSC3210
GUSC3210
10
15
20
30
40
GUSC3210
GUSC3210
GUSC3210
GUSC3210
GUSC3210
10
15
20
30
40
GB
GB
GB
GB
GB
2
10
15
20
30
40
1
1
1
1
1
GUSC3120
GUSC3120
GUSC3120
GUSC3120
GUSC3120
10
15
20
30
40
GUSC3120
GUSC3120
GUSC3120
GUSC3120
GUSC3120
10
15
20
30
40
GB
GB
GB
GB
GB
Dimensions
1A
In Inches:
GUSC single gang
Dimensions are approximate, not for construction purposes.
†See listings for catalog numbers which are suitable for use in Group B hazardous locations. Seals must be installed within 11/ 2" of all conduit openings.
Quicklag is a registered trademark of Cutler-Hammer Inc.
668
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
N2PB Circuit Breaker Panelboards
Factory Sealed Single & Two-Pole Breakers
1A
Watertight†
Cl. I, Div. 2, Groups C, D
Weatherproof
Cl. II, Div. 2, Groups F, G
Corrosion-Resistant
Dust-tight
NEMA 3, 7CD (Div. 2), 9FG (Div. 2), 12
Applications:
• N2PB panelboards are for use in central
control and protection of a large number
of feeder or branch circuits and for
housing circuit breakers in Class I,
Division 2, Groups C & D hazardous
areas.
Features:
• Enclosures are made of Krydon®, Eaton's
Crouse-Hinds' high impact strength
fiberglass-reinforced polyester material
with excellent corrosion resistance and
stability to heat
• Enclosure access door provided with
stainless steel thumb screws for easy
access; access door may be padlocked
to prevent unauthorized access
• Circuit breakers are contained in
compact, individual factory sealed
enclosures suitable for Class I, Division
2, Groups C, D hazardous areas
1A
Certifications and
Compliances:
• NEMA 3, 7CD (Div. 2), 9FG (Div. 2), 12
• NEC:
Class I, Division 2, Groups C, D
Class II, Division 2, Groups F, G
Options:
Description
Suffix
• Panelboard provided with (12)
operating handle lockouts for
lockout in ON or OFF positions
(any circuit). Stainless steel
lockout frame integral to panel
faceplate.
N2PB Size 14 x 26 ........................ L12
N2PB Size 24 x 26 ........................ L24
• Circuit breaker operating handle
lockout - order D2PB02
• Assortment of single-pole and
two-pole circuit breakers and trip
ratings – see listings
• Grounding plate or bushing –
see page 677
• Replacement circuit breaker
assemblies – see page 627
Circuit breaker panelboard – open view
Electrical Rating Ranges:
Size Ranges:
•
•
•
•
Panel
Designation
N2PB1426
N2PB2426
Circuit breakers
Single-pole – 120/240VAC max.
Two-pole – 120/240VAC max.
Trip ratings – 15, 20 and 30 amp.
Max. No. of Breakers
Single-Pole Two-Pole
12
24
6
12
†Watertight, weatherproof with door closed.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
669
N2PB Circuit Breaker Panelboards
1A
Factory Sealed Single & Two-Pole Breakers
Watertight†
Cl. I, Div. 2, Groups C, D
Weatherproof
Cl. II, Div. 2, Groups F, G
Corrosion-Resistant
Dust-tight
NEMA 3, 7CD (Div. 2), 9FG (Div. 2), 12
Ordering Information
Panelboards are available with 15, 20 or 30
ampere circuit breakers. To order a
panelboard with all breakers of the same
rating, add the desired rating as a suffix to
the Cat. No. For example, the 12 circuit
N2PB2426-2512 panelboard with all the
circuit breakers rated 20 amperes would
be ordered as N2PB2426-2512-20.
Panelboards listed below can also be
furnished with an assortment of single-pole
and two-pole breakers and breaker ratings.
To order, the quantities of breakers and
ampere ratings are added as suffixes to the
Cat. No. The total number of poles will
determine the panel size (24 poles max.),
and the wiring systems must be
compatible when combining single- and
two-pole circuit breakers.
Example: N2PB2426-2512-15 with threepole, 100 amp main circuit breaker would
be ordered as N2PB2426-2512-15-3M100.
If two-pole main is required, change the
number 3 to 2. If a lower trip rating is
required, the number will change
accordingly. Main breaker housing is
positioned on top of panel similar to D2PB
main. (See Section 1A.)
For example, a typical N2PB panelboard
with a combination of 5 single-pole 20
ampere, 3 single-pole 30 ampere, and 4
two-pole 30 ampere breakers would be
ordered as N2PB2426-2508-520-330-80430. The total number of poles is 16 and
wiring systems 25 and 8 are compatible 4
wire, 3 phase. The N2PB with a main
breaker is available up to 100 amps.
N2PB with main breaker, add appropriate
suffix.
1A
Enclosures with Single-Pole
Circuit Breakers
Max. No.
of Breakers
1 Pole 2 Poles
6
8
10
12
4
5
6
12
14
16
18
20
22
24
6
7
8
9
10
11
12
Enclosure
Only
Cat. #*
Panel Size
Enclosures with Two-Pole
Circuit Breakers
Wiring System 24
Wiring System 25
Wiring System 3
Wiring System 8
Mains: 3-Wire
Mains: 4-Wire,
3-Phase
Branches: 2-Wire,
1-Phase
Solid Neutral
Cat. #‡
Mains: 3-Wire
Solid Neutral
Cat. #‡
Mains: 4-Wire,
3-Phase
Branches: 3-Wire,
1-Phase
Solid Neutral
Cat. #‡
N2PB1426 804 ➀
N2PB1426 805 ➀
N2PB1426 806 ➀
Branches: 2-Wire
Main
Lug Solid Neutral
Size Cat. #‡
Branches: 3-Wire
N2PB1426
N2PB1426
14 x 26 x 81/ 2 N2PB1426 1 / 0 N2PB1426
N2PB1426
2406
2408
2410
2412
➀
➀
➀
➀
N2PB1426
N2PB1426
N2PB1426
N2PB1426
2506
2508
2510
2512
➀
➀
➀
➀
N2PB1426 304 ➀
N2PB1426 305 ➀
N2PB1426 306 ➀
N2PB2426
N2PB2426
N2PB2426
N2PB2426 4 / 0 N2PB2426
N2PB2426
N2PB2426
N2PB2426
2412
2414
2416
2418
2420
2422
2424
➀
➀
➀
➀
➀
➀
➀
N2PB2426
N2PB2426
N2PB2426
N2PB2426
N2PB2426
N2PB2426
N2PB2426
2512
2514
2516
2518
2520
2522
2524
➀
➀
➀
➀
➀
➀
➀
N2PB2426
N2PB2426
N2PB2426
N2PB2426
N2PB2426
N2PB2426
N2PB2426
24 x 26 x 81/ 2
Note on Hubs: Hubs must be ordered separately. See page 677 for listing.
➀ Add ampere rating. See ordering information above.
† Watertight, weatherproof with door closed.
‡ See page 677 for wiring diagrams.
*Accommodates D2CB breakers. Includes complete interiors, wiring system must be
specified. Example: N2PB2426 with wiring system 25 would be ordered as N2PB2426-25.
670
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
306
307
308
309
310
311
312
➀
➀
➀
➀
➀
➀
➀
N2PB2426
N2PB2426
N2PB2426
N2PB2426
N2PB2426
N2PB2426
N2PB2426
806
807
808
809
810
811
812
➀
➀
➀
➀
➀
➀
➀
N2PB Circuit Breaker Panelboards
Factory Sealed Single & Two-Pole Breakers
Watertight†
Cl. I, Div. 2, Groups C, D
Weatherproof
Cl. II, Div. 2, Groups F, G
Corrosion-Resistant
Dust-tight
NEMA 3, 7CD (Div. 2), 9FG (Div. 2), 12
1A
Dimensions
In Inches:
1A
N2PB
Cat. #
Nominal Inside
Dimensions
nw
nl
N2PB1426
N2PB2426
14
24
26
26
nd
Door Opening Dimensions
dw
dl
Mounting Dimensions
mw
ml
Alternate Mounting
Dimensions
mwa
mla
81/ 2
81/ 2
911/ 16
1911/ 16
117/ 8
213/ 4
153/ 8
251/ 4
2311/ 16
2311/ 16
271/ 4
271/ 4
233/ 4
233/ 4
Not to be used for construction purposes unless approved.
† Watertight, weatherproof with door closed.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
671
1A
NEMA 1, 3, 3R, 4, 4X, 12
NEMA PB1
UL/cUL Listed
XLPB Industrial Panelboards
Applications:
1A
XLPB Industrial Panelboards are used /
installed:
• In areas made corrosive due to the
presence of chemicals, salt water,
and/or moisture
• In locations where rough usage,
moisture, dust, dirt, and corrosion are a
problem
• In areas subject to weather, dampness,
or wash down requirements
• To provide, in one compact unit, a
centrally controlled switching system for
a large number of feeder or branch
circuits
• For branch power distribution and circuit
protection of motors, valves, pumps,
lighting, heat tracing, receptacles, etc.
• In indoor and outdoor installations
• To house thermal-magnetic circuit
breakers that provide disconnect means,
short circuit protection, and thermal time
delay overload protection
XLPB Panelboard Closed
Features and Benefits:
• Heavy-duty welded mounting feet
provide ease of installation (customer
can easily support the panel with bottom
mounting feet, while fastening the top
feet)
• High quality foam-in-place gasket
prevents ingress of water and corrosive
agents, reducing panel failure due to
moisture/corrosion
• An integral drainage channel allows for
opening the panel door without moisture
or dust seeping into panel from the top
side of the enclosure
• An internal/external ground stud
assembly enables rapid and reliable
protective ground connection
• Industrial grade NEMA 4X panel
designed for harsh environments
provides long product life
Standard Materials &
Finishes:
Electrical Ratings:
• 120/208, 240, 277/480, 480, and
347/600, 600 voltage panels
• 100 and 225 amp rated chassis
• Isolated neutral and ground bars
• Main breakers up to 225 amps
• 12, 18, 24, and 42 circuit panels
• 10kAIC
• 316L stainless steel or painted sheet
steel
• Eaton Pow-R-Line™ chassis
• Eaton Cutler-Hammer™ circuit breakers
• Stainless steel hardware
• High integrity foam-in-place gasket
• Industrial laminate insulate dead-front
cover
• SS316 quarter-turn screw driver entry
standard
Panel Capacity:
With Main
Breaker
Certifications and
Compliances:
• NEMA 1, 3, 3R, 4, 4X, 12
• NEMA PB1
• UL508A Listed / cUL Certified (CAN/CSA
C22.2, No. 14) (UL File E246968)
• UL67 components
• UL489/CAN/CSA C22.2, No. 5 circuit
breakers
XLPB Panelboard Open
120/208V (3P
120/240V (1P
277/480V (3P
347/600V (3P
CSA ONLY
4W)
3W)
4W)*
4W)
With
Panel Main
Size Lug 2-Pole 3-Pole Main Capacity
Main Capacity
Available
w/GFI/EPD
Branch
Protection
A
B
C
D
Up
Up
Up
Up
Up
Up
Up
Up
12
18
24
42
10
16
22
40
9
15
21
39
Up
Up
Up
Up
to
to
to
to
100
100
100
100
Amp
Amp
Amp
Amp
*277V EPD Branch Protection potentially available - single phase only (requires 2 breaker spaces)
672
www.crouse-hinds.com
US: 1-866-764-5454
480V (3P 3W)
277/480V (3P 4W)
600V (3P 3W)
347/600 (3P 4W)
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
to
to
to
to
225
225
225
225
Amp
Amp
Amp
Amp
to
to
to
to
240V*
240V*
240V*
240V*
XLPB Industrial Panelboards
NEMA 1, 3, 3R, 4, 4X, 12
NEMA PB1
UL/cUL Listed
1A
Ordering Information:
Example:
Example would be ordered as:
• NEMA 4X stainless steel
• 120/208 VAC 3-phase
• (8) 1-pole, 20 amp circuit breakers
• 3-pole, 100 amp main
• Bottom entry (inverted)
1. Panel Type
XLPB
XLPB A S 2 3 08 *08120 -3M100 -I
2. Size Enclosure
A = 12 circuit panelboard
B = 18 circuit panelboard
C = 24 circuit panelboard
D = 42 circuit panelboard
3. Enclosure Material Type
S = stainless steel
P = painted steel
4. Voltage
2 = 120/208, 240
4 = 480/277, 480
6 = 347/600
5. Phase
1 = single phase
3 = 3 phase
1A
6. Total Number of Branch Circuits
Refer to step 2 for maximum number of branch circuits per enclosure size.
Number of branch circuits equals combined number of branch
circuit breaker poles - i.e. qty. (8) 1-pole, 20 amp breakers = 08 poles
Option: Ambient compensated breakers for 50ºC, add suffix V after total
number of branch circuits
7. Branch Breaker Series
*Quantity, Pole, Amp
*08120 = qty. (08), 1-pole, 20 amp circuit breakers
Option: For GFI circuit breakers, add suffix G after Total Number of Branch
Circuits and Branch Breaker Series (ex. XLPBAS2308G*04120*04115G-3M100
Option: For EPD circuit breakers, add suffix E after Total Number of Branch
Circuits and Branch Breaker Series (ex. XLPBAS2308E*04120*04115E-3M100
8. Main Breaker
2 or 3 pole, 15 to 225A
Example: 3M100 = 3-pole main breaker, 100 amp
9. Options (see Options Section for more information)
Breathers and drains
Gland plates
Bottom feed inverted panelboard
Enclosure access handles
Key entry door access
External operators
Lighting contactor
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
673
1A
NEMA 1, 3, 3R, 4, 4X, 12
NEMA PB1
UL/cUL Listed
XLPB Industrial Panelboards
Options:
Description
Suffix Where Added
Ambient compensated breakers for 50ºC .......................................................V After Total Number of Branch Circuits
After Total Number of Branch Circuits and after
GFI - 5mA ground fault protection ..................................................................G
specific Branch Breaker Series
After Total Number of Branch Circuits and after
EPD - 30mA equipment protection ...................................... ...........................E
specific Branch Breaker Series
Breathers and drains to reduce moisture and corrosion.........................S756V End of Catalog Number
Gland plates for ease of installation ..................................... ........................GP End of Catalog Number
Bottom feed inverted panelboard .....................................................................I End of Catalog Number
Enclosure access handles ..........................................................................HLD End of Catalog Number
Key entry door access ................................................................................KED End of Catalog Number
External operators ...................................................................Contact Factory
Lighting contactor ...................................................................Contact Factory
Dimensions:
MOUNTING PLATE
DIMENSIONS (IN INCHES)
A
B
C
D
24 X 20
22"
18"
20"
16"
32 X 20
30"
18"
28"
16"
38 X 20
36"
18"
34"
16"
44 X 20
42"
18"
40"
16"
ENCLOSURE
SIZE
BOTTOM SIDE B
C
1A
MOUNTING
PLATE
B
D
B
E
F
H
24 X 20 X 07
24"
20"
7 3/16" 25 1/4"
14"
12"
6"
32 X 20 X 07
32"
20"
7 3/16" 33 1/4"
14"
17 3/4" 7 1/8"
38 X 20 X 07
38"
20"
7 3/16" 39 1/4"
14"
23 5/8" 7 3/16"
44 X 20 X 07
44"
20"
7 3/16" 45 1/4"
14"
29 1/2" 7 1/4"
7/16"
2-OFF ADDITIONAL HOLES
ON CENTRE LINE
FOR 38/20 & 44/20.
www.crouse-hinds.com
US: 1-866-764-5454
F
A
C
PROTECTION REMARK TO DIN 34 MUST BE OBSERVED
674
4-OFF
7mm THRU
HOLES FOR ALL SIZES
LEFT SIDE C
D
A
H
PLAN VIEW OF BOX
WITH LID FITTED
DIMENSIONS (IN INCHES)
A
7/16"
E
B
CAN: 1-800-265-0502
M10 INT/EXT
EARTHSTUD
Copyright© 2013 Eaton’s Crouse-Hinds Business
C
D
NLP Circuit Breaker Panelboards
With QO® Breakers
Applications:
Electrical Rating Ranges:
• NLP panelboards are for use in central
control and protection of a large number
of feeder or branch circuits and for
housing circuit breakers.
• QO® circuit breakers, single or two-pole
120/240VAC; three-pole 240VAC
• Trip ratings:
10 to 70 amps, single-pole
10 to 70 amps, two-pole
10 to 60 amps, three-pole
• Qwik-Gard® GFI circuit breakers:
Single-pole – 120 VAC 15 to 30 amps;
Two-pole – 120/240VAC
15 to 50 amps
Features:
• Enclosures are made of Krydon® high
impact strength fiberglass-reinforced
polyester material with excellent
corrosion resistance and stability to heat
• Enclosure access door provided with
stainless steel thumb screws for easy
access
• Access door may be padlocked to
prevent unauthorized access
• Standard with plug-on circuit breakers
Certifications and
Compliances:
Options:
• Assortment of circuit breaker trip ratings
– specify
• Assortment of single, two and three-pole
circuit breakers – specify
• Wiring system other than those listed –
specify
• Ground fault interrupter – circuit
breakers with built-in ground fault circuit
interrupters can be provided. These
interrupters cause the breaker to open
when a ground fault occurs. Suffix "GFI"
should be added after each circuit
breaker rating to be supplied with
ground fault interrupters
Ordering Information:
Panelboards are available with 10, 15, 20,
25, 30, 35, 40, 45, 50, 60 or 70 ampere
circuit breakers. To order a panelboard with
all breakers of the same rating, add the
desired rating as a suffix to the Cat. No. For
example, the 12 circuit NLPQ1426-2512 with
all circuit breakers rated 20 amperes would
be ordered as NLPQ1426-2512-20.
Panelboards can be furnished with an
assortment of breaker ratings. Where all
circuit breakers have the same number of
poles, assortments may be ordered by
adding the quantities and ampere ratings as
suffixes to the Cat. No. For example, the
12 circuit NLPQ1426-2512 with six 15 ampere,
four 40 ampere and two 50 ampere singlepole circuit breakers would be ordered as
NLPQ1426-2512-615-440-250.
1A
• NEMA 3 and 12
• UL Standard: 67
1A
Corrosion-Resistant
Dust-tight
Watertight*
Weatherproof
NEMA 3, 12
Example: An NLPQ panelboard using
wiring system 24 with four 15 ampere
breakers, two 40 ampere and four
50 ampere breakers and two 15 ampere
breakers, one 25 ampere breaker, and one
30 ampere breaker with GFI – Catalog No.
NLPQ1426-2414-415-240-450-215GFI125GFI-130GFI
Main Lug Only
3 Wire Branches (200A MLO)
Size Ranges:
Max. No. of Branch
Circuit Breakers
Mains
Rating
1-Pole 2-Pole 3-Pole
3w 4w 3w 4w 3w 4w
Panel Type Main Lug Only
NLPQ1426 200A
24 30 12 14
– 10
No of
Circuits
4
6
8
10
12
14
16
18
20
22
24
Enclosure
Only
NLPQ1426
NLPQ1426
NLPQ1426
NLPQ1426
NLPQ1426
NLPQ1426
NLPQ1426
NLPQ1426
NLPQ1426
NLPQ1426
NLPQ1426
1
1
1
1
1
1
1
1
1
1
1
Main
Lug‡
Amps
200
200
200
200
200
200
200
200
200
200
200
Enclosures with QON Interiors and QO® Branch
Circuit Breakers
1-Pole Branch Circuit
2-Pole Branch Circuit
Breakers
Breakers
Wiring System 24†
Wiring System 3†
NLPQ1426 2404 ➀
NLPQ1426 0304 ➀
NLPQ1426 2406 ➀
NLPQ1426 0306 ➀
NLPQ1426 2408 ➀
NLPQ1426 0308 ➀
NLPQ1426 2410 ➀
NLPQ1426 0310 ➀
NLPQ1426 2412 ➀
NLPQ1426 0312 ➀
NLPQ1426 2414 ➀
—
NLPQ1426 2416 ➀
—
NLPQ1426 2418 ➀
—
NLPQ1426 2420 ➀
—
NLPQ1426 2422 ➀
—
NLPQ1426 2424 ➀
—
* Watertight, weatherproof with door closed.
➀ Insert branch circuit breaker rating desired 10, 15, 20, 25, 30, 35, 40, 45, 50, 60 or 70 amp.
† See page 677 for wiring diagrams.
QO and Qwik-Gard are registered trademarks of Square D Company.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
675
NLP Circuit Breaker Panelboards
With QO® Breakers
1A
Corrosion-Resistant
Dust-tight
Watertight*
Weatherproof
NEMA 3, 12
4 Wire Branches (200A MLO)
No of
Circuits
4
6
8
10
12
14
16
18
20
22
24
26
28
30
Enclosure
Only
NLPQ1426 3
NLPQ1426 3
NLPQ1426 3
NLPQ1426 3
NLPQ1426 3
NLPQ1426 3
NLPQ1426 3
NLPQ1426 3
NLPQ1426 3
NLPQ1426 3
NLPQ1426 3
NLPQ1426 3
NLPQ1426 3
NLPQ1426 3
Main Lug‡
Amps
200
200
200
200
200
200
200
200
200
200
200
200
200
200
Enclosures with QON Interiors and QO® Branch Circuit Breakers
1-Pole Branch Circuit Breakers 2-Pole Branch Circuit Breakers 3-Pole Branch Circuit Breakers
Wiring System 25†
Wiring System 28†
Wiring System 11†
NLPQ1426 2504 ➀
NLPQ1426 2804 ➀
NLPQ1426 1104 ➀
NLPQ1426 2506 ➀
NLPQ1426 2806 ➀
NLPQ1426 1106 ➀
NLPQ1426 2508 ➀
NLPQ1426 2808 ➀
NLPQ1426 1108 ➀
NLPQ1426 2510 ➀
NLPQ1426 2810 ➀
NLPQ1426 1110 ➀
NLPQ1426 2512 ➀
NLPQ1426 2812 ➀
—
NLPQ1426 2514 ➀
NLPQ1426 2814 ➀
—
NLPQ1426 2516 ➀
—
—
NLPQ1426 2518 ➀
—
—
NLPQ1426 2520 ➀
—
—
NLPQ1426 2522 ➀
—
—
NLPQ1426 2524 ➀
—
—
NLPQ1426 2526 ➀
—
—
NLPQ1426 2528 ➀
—
—
NLPQ1426 2530 ➀
—
—
The NLP and NLPQ panelboards accommodate Square D NQOD and QON interiors as follows.
Enclosure
3 Wire Branches
4 Wire Branches
NLPQ1426
QON124L200I
QON330L200
When ordering enclosures only, interiors and circuit breakers are not included and must be ordered separately from Square D.
1A
Note:
Dimensions
In Inches:
NLP
Cat. #
Nominal Inside
Dimensions
nw
nl
NLP1426
14
26
nd
Door Opening
Dimensions
dw
dl
Mounting Dimensions
mw
ml
Alternate Mounting
Dimensions
mwa
mla
81/2
911/16
117/8
153/8
2311/16
271/4
Not to be used for construction purposes unless approved.
* Watertight, weatherproof with door closed.
➀ Insert branch circuit breaker rating desired, 10, 15, 20, 25, 30, 35, 40, 45, 50, 60 or 70 amp.
‡ 200A QON main lugs are #4/0 Cu/Al.
† See page 677 for wiring diagrams.
Note: Hubs, grounding plates and bushings must be ordered separately. See page 677 for listing.
676
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
233/4
1A
Accessories
Hubs
Conduit
Size
Hole
Size
Hub
Cat. #
Krydon® material hubs for conduit
entrances, in sizes 1/2" through 3" are
available for factory or field installation in
all enclosures made of Krydon material.
For factory installation, send drawing
showing sizes and locations of hubs.
Furnished with and gaskets to assure.
/2
/4
1
11/4
11/2
2
21/2
3
7
/8
11/8
13/8
13/4
2
21/2
3
35/8
NHUB1
NHUB2
NHUB3
NHUB4
NHUB5
NHUB6
NHUB7
NHUB8
1
3
Standard Materials:
• Up to 11/2" – Krydon material with steel
interiors
• 2", 21/2" and 3" – Krydon material with
Feraloy® iron alloy interiors
Grounding Plates and Grounding Bushings
Standard Finishes:
• Krydon material – natural
• Steel – electrogalvanized and bleached
chromate
• Feraloy iron alloy – electrogalvanized
• Grounding plates – steel
• Grounding bushings – steel with
thermoplastic insulating throat
Standard Finishes:
• Steel – electrogalvanized
Conduit
Size
Grounding
Plate Cat. #
Grounding
Bushing Cat. #
/2
/4
1
11/4
11/2
2
21/2
3
GP1
GP2
GP3
GLS1
GLS2
GLS3
GLS4
GLS5
GLS6
GLS7
GLS8
1
3
1A
Standard Materials:
Grounding Plates (1/ 2" through 1") and insulated bushings (1/ 2" through 3") permit use of the
conduit as the grounding circuit. Both types have set screws and ground-wire terminals.
Wiring Diagrams for Circuit Breaker Panelboards
System 3
Mains—3-Wire
Branches—3-Wire
Breakers—2-Pole
Solid Neutral
System 8
Mains—4-Wire, 3-Phase
Branches—3-Wire, 1-Phase
Breakers—2-Pole
Solid Neutral
System 11
Mains—4-Wire, 3-Phase
Branches—4-Wire, 3-Phase
Breakers—3-Pole
Solid Neutral
System 24
Mains—3-Wire
Branches—2-Wire
Breakers—Single-Pole
Solid Neutral
System 25
Mains—4-Wire, 3-Phase
Branches—2-Wire
Breakers—Single-Pole
Solid Neutral
System 28
Mains—4-Wire, 3-Phase
Branches—3-Wire, 1-Phase
Breakers—2-Pole
Solid Neutral
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
677
1A
1A
678
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
2A
Switches
Hazardous and Non-hazardous
Description
Page No.
Application/Selection
see page 680
Enclosed Switches
Heavy Duty
FLS
N2RS
WST/W2ST
see page 685
see page 690
see page 696
General Use Snap Switches
EFD, EFDC, EDS, EDSC
FSPC
GUSC
Manual Contactors
see pages 694–695
see page 692
see page 691
see page 700
Disconnect Switches
see page 681
see page 682
see page 683
see pages 698–699
see pages 701–702
see pages 686–689
Light Switch
GHG273
www.crouse-hinds.com
US: 1-866-764-5454
see page 693
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
679
2A
EID (Non-fused)
EID (Fused)
EBM
NRS
NST
GHG
2A
Switches
Application and Selection
Quick Selector Chart
Applications:
• Switches and enclosures are used in
hazardous and non-hazardous areas to
disconnect motor, lighting and other
circuits and prevent arcing of the
enclosed switch from igniting hazardous
atmospheres.
Quick Selector Chart
Options:
Considerations for
Selection:
Enclosure Location:
• NEC/CEC and NEMA/EEMAC
compliances for hazardous areas and/or
wet and dirty locations
Electrical:
• Consistency with the functions to be
performed
Application:
• Selection of appropriate switch and
operating mechanism
• Optional material and finishes available
for highly corrosive atmospheres
• Various hub sizes are available to suit
particular applications
Electrical Rating
NEC/CEC & NEMA/EEMAC
Compliances
NEMA/EEMAC: 3R, 4, 12
Max.
Amps
100
Max.
Volts
600VAC
250VDC
Max.
HP
75
Switch
Type
Visible blade
Heavy duty
Fused or
Unfused
Fused & unfused
EDS, EDSC,
EFD, EFDC
Cl. I, Div. 1 & 2, Groups B, C, D;
Cl. II, Div. 1, Groups E, F, G;
Cl. II, Div. 2, Groups F, G;
Cl. III;
NEMA/EEMAC: 3, 7BCD, 9EFG, 12
30
277VAC
2
General use snap
Unfused
FSPC
Cl. I, Div. 1 & 2, Groups A, B, C, D;
Cl. II, Div. 1, Groups E, F, G;
Cl. II, Div. 2, Groups F, G;
Cl. III;
NEMA/EEMAC: 3, 7ABCD, 9EFG, 12
20
277VAC
2
General use snap
Unfused
GUSC
Cl. I, Div. 1 & 2, Groups C, D;
Cl. II, Div. 1, Groups E, F, G;
Cl. II, Div. 2, Groups F, G;
Cl. III;
NEMA/EEMAC: 3, 7CD, 9EFG, 12
30
600VAC
2
General use snap
Unfused
FLS
Cl. I, Div. 1 & 2, Groups C, D;
Cl. II, Div. 1, Groups E, F, G;
Cl. II, Div. 2, Groups F, G;
Cl. III;
NEMA/EEMAC: 3, 4, 7CD, 9EFG, 12
100
600VAC
50
Visible blade
Disconnect
Unfused
EBM
Cl. I, Div. 1 & 2, Groups B, C, D;
Cl. II, Div. 1, Groups E, F, G;
Cl. II, Div. 2, Groups F, G;
Cl. III;
NEMA/EEMAC 3, 4, 7BCD, 9EFG, 12
100
600VAC
75
Visible blade
Disconnect
Fused & unfused
NRS
NEMA/EEMAC: 3, 4X, 12
100
600VAC
75
Rotary - Disconnect
Fused & unfused
N2RS
Cl. I, Div. 2, Groups B, C, D;
NEMA: 3, 4X, 12
100
600VAC
60
Rotary - Disconnect
Unfused
NST
NEMA: 3, 4X, 12
200
600VAC
250VDC
125
Visible blade
Disconnect
Fused & unfused
Manual
Contactors
NEMA/EEMAC: 3R
30
600VAC
15
Contacts, snap
Unfused
GHG
Cl. I, Div. 2, Groups A, B, C, D;
Cl. II, Div. 1, Groups E, F, G;
Cl. I, Zones 1 & 2, Ex de IIB+H, Ex de IIC
180
600VAC
150
Rotary, snap
Unfused
EID
Cl.
Cl.
Cl.
Cl.
400
600VAC
350
Rotary - Disconnect
Fused & unfused
2A
Switch
Enclosure
WST
680
I, Div. 1 & 2, Groups B, C, D;
I, Zones 1 & 2;
II, Div. 1, Groups E, F, G;
III
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
EID Disconnect Assembly
Cl. I, Div. 1 & 2, Groups B, C, D
Cl. I, Zones 1 & 2
Cl. II, Div. 1, Groups E, F, G
Cl. III
Non-fused
Applications:
• Provides an explosionproof disconnect
switch assembly for hazardous area
electrical systems
• Incorporates Eaton's Crouse-Hinds' high
integrity manufacturing standards for
reliability and safety in a compact,
space-efficient NEMA 4 enclosure
Features and Benefits:
2A
Certifications and
Compliances:
•
•
•
•
•
Class I, Divisions 1 & 2, Groups B, C, D
Class I, Zones 1 & 2
Class II, Division 1, Groups E, F, G
Class III
Enclosure Type 3, 3R, 4 or 4X*, 7BCD,
9EFG
• UL Standard 1203
• cUL to CSA C22.2 No. 30
Standard Materials:
• Body and Cover—Copper-free
Aluminum
• Gasket—Neoprene
• Cover Bolts—Steel
• Hinges—Stainless Steel
• Mounting Plate Sheet—Aluminum
• Rotary Actuating Handle—Aluminum
Standard Finishes:
• Copper-free Aluminum—Natural
• Steel—Electro-galvanized
Electrical Ratings:
Weights:
EIDA
EIDB
36 lbs
62 lbs
16 kg
28 kg
Options:
Description
Suffix
Auxiliary Contact (single block) ....... S784
Auxiliary Contacts (two blocks) ....... S785
Breather and Drain .......................... S756V
Epoxy Powder Coat Finish
(external only) .................................. S752
Epoxy Powder Coat Finish
(internal and external) ...................... S753
External Ground Lug ....................... S214
Non-fused HP Rating at:
Amps
200V 208V 240V 480V 600V
30
60
100
200
400
10
20
25
-
10
20
25
-
10
20
30
75
125
20
40
50
150
250
30
40
50
200
350
Ordering Information:
Switch Rating Enclosure Enclosure
(Amps)
Only
with Switch
30
60
100
200
400
EIDA
EIDA
EIDB
-
EIDA3030
EIDA3060
EIDB3100
EIDC3200‡
EIDD3400‡
Dimensions:
EIDA
EIDB
A
9.65"
245mm
11.75"
298mm
B
5"
127mm
7"
178mm
C
10.47"
266mm
12.53"
318mm
D
11.13"
283mm
15.13"
384mm
E
12.47"
317mm
16.53"
420mm
F
2.75"
2.75"
*When ordered with S752 or S753 suffix.
**When ordered with S756V suffix.
†For both drains and auxiliary contacts, please contact factory.
‡Contact Customer Service for additional specifications.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
681
2A
• Can be ordered as enclosure only,
allowing for field installation of switch
while maintaining product certification
• NEMA 4X breather and drain** provides
a moisture control solution in hose-down
applications
• Small, compact footprint - less mounting
space required
• Large red painted aluminum rotary
handle operator mounted on cover
assembly provides rugged, reliable
performance in the field and allows for
the position of the switch to be easily
identified from a distance
• Neoprene cover gasket provides UL
Type 4 (hosetight) environmental rating
• Detachable/adjustable mounting feet
provide flexible mounting alternatives for
ease of installation; no need to replace
the entire enclosure if a mounting foot is
broken
• Stainless steel hinges provide easy
access to inside of enclosure for wiring
and maintenance
• (2) Conduit entries, one on top and one
on bottom (EIDA—1" NPT entries,
EIDB—1 1/2" NPT entries) for easy top or
bottom feed of conductors
• (2) 1/ 2" NPT conduit entries, one on top
and one on bottom, for field addition of
breather and/or drain or for use with
auxiliary contacts; †holes come plugged
with Eaton's Crouse-Hinds PLG
explosionproof as standard
• Provides lockout/tagout capability which
complies with OSHA requirements,
allowing for locking in the ON or OFF
position for standard maintenance
checks
• Complies with NEC Article 312 wire
bending requirements for max gauge
wire, allowing for easy and safe
installation, and reliable operation of
product
UL/cUL Listed
Enclosure Type 3, 3R, 4, 4X*,
7BCD, 9EFG
2A
EID Disconnect Assembly
Fused
Applications:
• Provides an explosionproof disconnect
switch assembly for hazardous area
electrical systems
• Incorporates Eaton's Crouse-Hinds' high
integrity manufacturing standards for
reliability and safety in a compact, spaceefficient NEMA 4 enclosure
2A
Features and Benefits:
• NEMA 4X breather and drain** provides
a moisture control solution in hosedown applications
• Small, compact footprint - less mounting
space required
• Large red painted aluminum rotary
handle operator mounted on cover
assembly provides rugged, reliable
performance in the field and allows for
the position of the switch to be easily
identified from a distance
• Neoprene cover gasket provides UL
Type 4 (hosetight) environmental rating
• Detachable/adjustable mounting feet
provide flexible mounting alternatives for
ease of installation; no need to replace
the entire enclosure if a mounting foot is
broken
• Stainless steel hinges provide easy
access to inside of enclosure for wiring
and maintenance
• (2) Conduit entries, one on top and one
on bottom for easy top or bottom feed
of conductors
• (2) NPT conduit entries, one on top and
one on bottom, for field addition of
breather and/or drain or for use with
auxiliary contacts; †holes come plugged
with Eaton's Crouse-Hinds PLG
explosionproof as standard
• Provides lockout/tagout capability which
complies with OSHA requirements,
allowing for locking in the ON or OFF
position for standard maintenance
checks
Cl. I, Div. 1 & 2, Groups B, C, D UL/cUL Listed
Enclosure Type 3, 3R,
Cl. I, Zones 1 & 2
4, 4X*, 7BCD, 9EFG
Cl. II, Div. 1, Groups E, F, G
Cl. III
Certifications and
Compliances:
•
•
•
•
•
Class I, Divisions 1 & 2, Groups B, C, D
Class I, Zones 1 & 2
Class II, Division 1, Groups E, F, G
Class III
Enclosure Type 3, 3R, 4 or 4X*, 7BCD,
9EFG
• UL Standard 1203
• cUL to CSA C22.2 No. 30
Standard Materials
•
•
•
•
•
•
Body and Cover—Copper-free Aluminum
Gasket—Neoprene
Cover Bolts—Steel
Hinges—Stainless Steel
Mounting Plate Sheet—Aluminum
Rotary Actuating Handle—Aluminum
Standard Finishes:
Ordering Information:
Switch Rating
(Amps)
Enclosure with
Switch
30
60
100
200
400
EIDAF3030
EIDAF3060
EIDBF3100
EIDCF3200
EIDDF3400
Note:
Fuses are not included (Type J recommended).
Note:
Contact Customer Service for additional
specifications.
• Copper-free Aluminum—Natural
• Steel—Electro-galvanized
Options:
Electrical Ratings:
Fused
HP Rating at:
Amps
30
60
100
200
400
240V
480V
600V
60
125
15
30
60
125
250
20
50
75
150
350
Description
Suffix
Auxiliary Contact (single block) . . .S784
Auxiliary Contacts (two blocks) . . . S785
Breather and Drain . . . . . . . . . . . . .S756V
Epoxy Powder Coat Finish
(external only) . . . . . . . . . . . . . . . . .S752
Epoxy Powder Coat Finish
(internal and external) . . . . . . . . . . .S753
External Ground Lug. . . . . . . . . . . . S214
*When ordered with S752 or S753 suffix.
**When ordered with S756V suffix.
†For both drains and auxiliary contacts, please contact factory.
682
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
EBM Disconnect Switches
and Enclosures
Cl. I, Div. 1 & 2, Groups B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 3R, 4‡, 4X††, 7BCD, 9EFG, 12
600 VAC Heavy Duty
Applications:
EBM series hinged cover disconnect
switches are used:
• To disconnect motor, lighting and other
circuits.
• In locations made hazardous by the
presence of flammable gases or vapors
or ignitable dusts.
• Indoors or outdoors in damp, wet and
dirty locations, or in areas where
frequent washdowns, heavy rain or
water spray is prevalent.
• To provide disconnect means and short
circuit protection (fusible version).
• On switchracks or other assemblies
where it is desired that motor control be
centrally located.
2A
Explosionproof
Dust-Ignitionproof
Watertight
Wet Locations
Certifications and
Compliances:
• NEC/CEC:
Class I, Division 1 & 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• UL Standards: UL1203
• High A.I.C. Rating (Interrupting Capacity)
- For Class I, Div. 1, Groups C & D only
Volt
RMS Symm-Amperes
240
480
600
65,000
50,000
25,000
• CSA Standard: C22.2 No. 30
• NEMA: 3, 3R, 4‡, 4X††, 7BCD, 9EFG, 12
Features:
Standard Materials:
• Body and cover – copper-free aluminum
• Operating handle – copper-free
aluminum
• Operating shaft and bushing – stainless
steel
• Interior parts – sheet steel,
electrogalvanized
• Cover bolts, washers and retractile
springs – stainless steel
• Hinges – stainless steel
2A
• Rugged corrosion resistant cast copperfree aluminum construction
(less than 0.4 of 1%).
• Switch operating handle is located
through the right side wall of the body,
permits visual confirmation of correct
alignment and operation.
• Total compliance to the wiring end room
requirements of the National
Electrical Code.
• Semi-clamshell enclosure design, with
an external flanged ground joint between
body and cover makes interior
components more accessible.
• Minimum enclosure-to-enclosure
spacing with little interference between
the opened cover and an adjacent
enclosure.
• Stainless steel hinges allow the cover to
swing well out of the way.
• Stainless steel quick release captive
hexhead cover bolts. Stainless steel
springs provide clear indication that
cover bolts are fully retracted from the
body.
• Switch operating handle can be
padlocked in either the "ON" or "OFF"
position.
• Neoprene cover gasket permanently
attached to the cover seals out moisture.
• Bodies have top and bottom drilled and
tapped conduit entrances for power and
conduits. Removable reducers are
supplied as standard, to accommodate
smaller size conduits. All conduit
entrances are plugged.
• Tap on mounting feet.
Ordering Information:
To order an enclosure complete with the
disconnect switch, select the catalog
number (based on the necessary rating of
the switch), from the listing below.
Enclosures only, without the disconnect
switch, can be ordered. Select the catalog
number for the required enclosure from the
listing below.
Electrical Rating Ranges:
• 600 VAC
• 30, 60 and 100 Amp
Max. HP Rating
Amp
AC Polyphase
Rating 200/240V 440/480V
Non-Fusible
30
10
20
60
20
40
100
30
75
550/600V
Enclosure
DC using 2
poles only With Switch
250V Max. 600VAC Cat. #
25
60
75
71/2
15
25
EBMBB FD W30360 EBMBB FD
EBMBB FD W60360 EBMBB FD
EBMBD FD W10360 EBMBD FD
Fusible
30
—
60
—
100
15
71/2
15
30
5
10
20
EBMBB FD W30361 EBMBB FD
EBMBB FD W60361 EBMBB FD
EBMBD FD W10361 EBMBD FD
5
15
25
Without
Switch
Cat. #
Options:
• For available options, see pages 494–495.
‡ Enclosure not suitable for NEMA 4 or 4X with cover mounted operators.
††With S752 or S753.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
683
Cl. I, Div. 1 & 2, Groups B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 3R, 4‡, 4X††, 7BCD, 9EFG, 12
EBM Disconnect Switches
and Enclosures
2A
600 VAC Heavy Duty
Explosionproof
Dust-Ignitionproof
Watertight
Wet Locations
Dimensions
2A
In Inches:
Dimensions are approximate, not for construction purposes.
*1" D & T conduit entry for control conductors supplied with PLG plug top and bottom.
**Conduit entrance(s) for power conductors (top and bottom). (All conduit entrance(s) supplied with RE reducer and PLG plug.)
G
**J Conduit
Entry Trade
Size
D&T† w/RE
K
L
M
P
14.46
10.25
2"
1.5"
3.25
3.13
10.25
22.00
14.46
10.25
3"
2.5"
3.25
3.13
10.25
24.50
Enclosure
Only
Cat. #
Enclosure
Size
Symbol
A
B
C
D
E
F
30 and 60
Amp Frame
EBMBB
B
25.75
24.75
26.90
6.00
13.03
100 Amp
Frame
EBMBD
D
28.25
27.25
29.40
6.00
13.03
‡ Enclosure not suitable for NEMA 4 or 4X with cover mounted operators.
††With S752 or S753.
†Drilled & Tapped.
684
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
FLS Enclosed Switches
Heavy Duty
Applications:
Standard Materials:
FLS heavy duty enclosed switches are
used:
• In a rigid metallic conduit system for
surface mounting adjacent to or remote
from equipment being controlled
• As disconnect switches for main feed or
individual motor control
• To prevent arcing of the enclosed switch
from causing ignition of a specific
hazardous atmosphere, or atmospheres,
external to the enclosure
• In industrial areas such as chemical
plants, oil and gas refineries, paint and
varnish manufacturing plants, gasoline
bulk loading terminals, grain elevators,
grain processing industries, coal
processing or handling areas and metal
handling or finishing areas where
atmosphere may contain hazardous
gases and/or dust
• In non-hazardous area where sturdy,
durable enclosures are required
•
•
•
•
2A
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 4, 7CD, 9EFG, 12
Body – copper-free aluminum
Cover – copper-free aluminum
Shaft – stainless steel
Shaft bushings – stainless steel
Standard Finishes:
• Copper-free aluminum – natural
• Stainless steel – natural
Options:
Description
Ground/neutral wire stud provided
Breather and Drain
Auxiliary switch: 1A, 1B
Auxiliary switch: 2A, 2B
Suffix
S168
S198V
S784
S785
Size Ranges:
• Hub size – 11/2" through feed with top
entry having a PLG5 plug
2A
Ordering Information:
Features:
Furnished with Non-Fusible, Visible Blade Motor Circuit Switch
• Enclosed devices are unfused, visible
blade motor circuit switches
• Rugged cast metal enclosures with
mounting lugs and taper tapped hubs
with integral bushings, in through feed
arrangement
• Interior of the enclosures is readily
accessible through threaded cover
openings at each end, set at an angle to
facilitate wiring
• Threaded covers and a threaded type
operating shaft and bushing provide
quick assembly and easy maintenance
• A padlock can be used to lock the
operating handle in an "ON" or "OFF"
position
• Body and cover threads treated with
lubricant at factory to provide
raintightness
Switch Ratings
Amperes
Maximum HP – 3 Phase
Volts AC
125
240
480
600
30
60
100
5
10
15
10
20
30
20
40
75
25
60
75
250 VDC
Through Feed
Hub Size
Enclosure With
3-Pole Switch
Cat. #
7.5
15
25
11/2"
11/2"
11/2"
FLS30364 1 33
FLS60364 1 44
FLS10364 1 55
Dimensions
In Inches:
Certifications and
Compliances:
• NEC:
Class I, Divisions 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• NEMA: 3, 4, 7CD, 9EFG, 12
• UL Standard: 1203
Dimensions are approximate, not for construction purposes.
a
71/2
www.crouse-hinds.com
b
c
d
e
f
g
131/8
81/2
93/4
91/8
7
/16
13/4
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
685
2A
Explosion Protected Disconnect
Switches
10, 20, 40, 80, 125 and 180 Amp
600VAC Non-metallic Enclosure
cCSAus Certified
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zones 1 and 2, AEx de IIC, T6
Cl. II, Div. 1, Groups E, F, G (CSA)
Cl. II, Div. 2, Groups F, G
ATEX Approved
Ex de IIC, T6, Zones 1 and 2, IP66
Applications:
Explosion Protected Disconnect Switches
are used in a metallic conduit or cable
system for surface mounting to control
motor, lighting, and other circuits and:
• For individual motor control
• Are used to prevent arcing internal to the
enclosed switch from causing ignition of
a specific hazardous atmosphere or
atmospheres
• Are designed for industrial areas such as
chemical plants, oil and gas refineries,
paint and varnish manufacturing plants,
gasoline bulk loading terminals, and
finishing areas where sturdy, durable
enclosures are required
2A
Features:
• Explosion protected factory sealed
motor circuit switches.
• Innovative break-line in cover allows full
wiring access, making installation quick
and easy.
• High-impact enclosure is designed for
excellent corrosion resistance and will
not warp from hot or cold water.
• Tongue-in-groove seal guarantees IP66
rating and eliminates possibility of
accidental opening or leakage.
• Lockable handle meets OSHA lockout/
tagout requirements.
• Molded-in-place mounting feet provide a
water channel between wall and
enclosure.
• Large rotary handle provides easy
gripping with gloved hands.
• Captive cover screws prevent water
exposure and possible corrosion.
Standard Materials:
• Enclosure
10A: Impact-resistance thermoplastic
20A – 180A: Fiberglass-reinforced polyester
Non-metallic, corrosion resistance
Increased safety Ex-e protection
Impact Resistance
NEMA 4X, IP66 Protection
Enclosure meets UL 94-V0
UV Rated
• Enclosure Gasket – Silicon
• Handle – Impact-resistant thermoplastic
• Cover Screws – Stainless steel
• Conduit Entries: Zinc Myers™ Hubs
Certifications and
Compliances:
Electrical Rating Ranges:
•
•
•
•
•
•
•
•
•
•
•
Switches:
Horsepower Ratings:
cCSAus Certified
Class I, Division 2, Groups A, B, C, D
Class I, Zones 1 and 2, AEx de IIC, T6
Class II, Division 1, Groups E, F, G (CSA)
Class II, Division 2, Groups F, G
ATEX Approved - PTB
Ex de IIC, T6, Zones 1 and 2A, IP66
GOST-R and GOST-K
CSA Standard: C22.2 No.14
NEMA 4X
IP66
686
www.crouse-hinds.com
US: 1-866-764-5454
GHG
GHG
GHG
GHG
GHG
GHG
261
262
263
264
265
266
CAN: 1-800-265-0502
10A
20A
40A
80A
125A
180A
240 VAC
600 VAC
0.75
14.3
20
50
40
40
–
12.2
15
30
75
75
Copyright© 2013 Eaton’s Crouse-Hinds Business
cCSAus Certified
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zones 1 and 2, AEx de IIC, T6
Cl. II, Div. 1, Groups E, F, G (CSA)
Cl. II, Div. 2, Groups F, G
ATEX Approved
Ex de IIC, T6, Zones 1 and 2, IP66
Explosion Protected Disconnect
Switches
10, 20, 40, 80, 125 and 180 Amp
600VAC Non-metallic Enclosure
2A
Ordering Information:
10 AMP
20 AMP
Pole
3 Pole
3 Pole
6 Pole
3 Pole
6 Pole
Rated Voltage
500 V
690 V
690 V
690 V
690 V
Auxiliary Contact
1 NO, making – lagging
breaking – leading
1 NO, making – lagging
breaking – leading
1 NC
1 NO, making – lagging
breaking – leading
1 NC
Auxiliary
Connection
14 AWG
2 x 2.5 mm2
12 AWG
2 x 4 mm2
12 AWG
2 x 4 mm2
12 AWG
2 x 16 mm2
12 AWG
2 x 16 mm2
Connection
Terminals
14 AWG
12 AWG
12 AWG
6 AWG
6 AWG
Conduit Entries
1 x 3/4"
2 x 3/4"
2 x 3/4"
2 x 3/4"
2 x 1"
Cat. #
GHG 261 0005 L0002
GHG 262 2301 L0003
GHG 262 2601 L0002 GHG 263 2301 L0002
Weight
0.55 kg
1.5 kg
2.3 kg
Dimensions
See Figure 1
See Figure 2
See Figure 3
Wall Mounting
Plate
GHG6101953R0101
GHG 610 1953 R0104
GHG 610 1953 R0118 GHG 610 1953 R0118
1.2 lbs.
40 AMP
3.3 lbs.
5.1 lbs. 2.3 kg
80 AMP
GHG 263 0050 L0002
5.1 lbs.
6.5 kg
See Figure 4
14.3 lbs.
See Figure 5
not required
180 AMP
3 Pole
6 Pole
3 Pole
3 Pole
Rated Voltage
690 V
690 V
690 V
690 V
Auxiliary Contact
1 NO, making – lagging
breaking – leading
1 NC
1 NO, making – lagging
breaking – leading
1 NO, making – lagging
breaking – leading
Auxiliary Connection
12 AWG
2 x 50 mm2
12 AWG
2 x 50 mm2
12 AWG
1 x 70 mm2
12 AWG
1 x 120 mm2
4 / 0 AWG
2A
125 AMP
Pole
Connection Terminals
2 AWG
2 AWG
2 / 0 AWG
Conduit Entries
2 x 11/2"
2 x 11/2"
2 x 11/2"
2 x 2"
Cat. #
GHG 264 0020 L0017
GHG 264 0021 L0002
GHG 265 0010 L0003
GHG 266 0006 L0002
Weight
6.5 kg
9.0 kg
16.0 kg
16.5 kg
Dimensions
See Figure 6
See Figure 7
See Figure 8
See Figure 8
Wall Mounting Plate
not required
not required
not required
not required
14.3 lbs.
19.8 lbs.
35.2 lbs.
36.3 lbs.
For Variable Speed, Three Phase Drives
20 AMP
40 AMP
Pole
3 Pole
3 Pole
3 Pole
Rated Voltage
690 V
690 V
690 V
Auxiliary Contact
1 NO, making – lagging
breaking – leading
1 NO, making – lagging
breaking – leading
1 NO, making – lagging
breaking – leading
Auxiliary Connection
12 AWG
2 x 4 mm2
6 AWG
2 x 16 mm2
2 AWG
2 x 35 mm2
Connection
Terminals
12 AWG
6 AWG
Conduit Entries
2 x /4"
1 x 1" + 1 x /2"
1 x 11/2" + 1 x 1/2"
Cat. #
GHG 262 0014 L0001
GHG 263 0053 L0001
GHG 264 0024 L0001
Weight
1.6 kg
2.3 kg
3.5 kg
Dimensions
See Figure 9
See Figure 10
See Figure 11
Wall Mounting Plate
GHG 610 1953 R0118
GHG 610 1953 R0118
GHG6101953R0110
3
80 AMP
2 AWG
1
3.5 lbs.
5.1 lbs.
7.7 lbs.
Switches can be mounted directly onto a wall. The optional wall mounting plate offers a more convenient method of mounting.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
687
2A
Explosion Protected Disconnect
Switches
10, 20, 40, 80, 125 and 180 Amp
600VAC Non-metallic Enclosure
cCSAus Certified
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zones 1 and 2, AEx de IIC, T6
Cl. II, Div. 1, Groups E, F, G (CSA)
Cl. II, Div. 2, Groups F, G
ATEX Approved
Ex de IIC, T6, Zones 1 and 2, IP66
Dimensions
In Inches:
2A
Figure 1 - 10 Amp, 3 Pole
688
Figure 2 - 20 Amp, 3 Pole
Figure 3 - 20 Amp, 6 Pole
Figure 4 - 40 Amp, 3 Pole
Figure 5 - 40 Amp, 6 Pole
Figure 6 - 80 Amp, 3 Pole
Figure 7 - 80 Amp, 6 Pole
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
cCSAus Certified
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zones 1 and 2, AEx de IIC, T6
Cl. II, Div. 1, Groups E, F, G (CSA)
Cl. II, Div. 2, Groups F, G
ATEX Approved
Ex de IIC, T6, Zones 1 and 2, IP66
Explosion Protected Disconnect
Switches
10, 20, 40, 80, 125 and 180 Amp
600VAC Non-metallic Enclosure
2A
Dimensions
In Inches:
2A
Figure 8 - 125 Amp, 3 Pole 180 Amp, 3 Pole
Figure 9 - 20 Amp, 3 Phase Variable Speed
Figure 10 - 40 Amp, 6 Phase Variable Speed
Figure 11 - 80 Amp, 3 Phase Variable Speed
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
689
2A
Cl. I, Div. 2, Groups B, C, D
NEMA 3, 4X, 7 (B, C, D Div. 2), 12
Watertight
Dust-tight
Factory Sealed
N2RS Enclosed Switches
2A
Heavy-Duty
Applications:
Standard Materials:
N2RS heavy-duty enclosed switches are
used:
• In a rigid metallic conduit or cable
system for surface mounting adjacent to
or remote from equipment being
controlled.
• For individual motor control.
• To prevent arcing internal to the
enclosed switch from causing ignition of
a specific hazardous atmosphere, or
atmospheres.
• In industrial areas such as chemical
plants, oil and gas refineries, paint and
varnish manufacturing plants, gasoline
bulk loading terminals, and finishing
areas where atmospheres may contain
hazardous gases.
• In non-hazardous areas where sturdy,
durable enclosures are required.
• When controlling motor, lighting and
other circuits.
• Enclosure – Krydon material
• External Hardware – Stainless Steel
• Operating Handle – Nylon
Size Ranges:
• Hub size:
(2) 11/2" (30, 60 amps)
(2) 21/2" (100 amps)
Krydon material hubs included (not
mounted)
Ordering Information
Furnished with Non-Fusible, Factory Sealed Motor Circuit Switch
Features:
Switch Ratings
• Enclosed devices are unfused, factory
sealed motor circuit switches.
• Exceeds NEC® wiring end room
requirements for ease of installation.
• RSWP factory sealed industrial control
switch, no external seals are required.
• Enclosure is made of Krydon® highimpact strength fiberglass-reinforced
polyester material having excellent
corrosion resistance and stability to heat.
• Krydon material hubs with integral
bushings, for dead-end or through-feed
arrangements are supplied.
• Krydon material mounting feet supplied.
• Suitable for wash down and corrosive
areas (Type 4X).
• A padlock can be used to lock the
operating handle in the "OFF" position.
• Rotary actuator with snap action.
• Unitized, strong and durable
construction provides longer service life
for equipment.
• Factory sealed 10A, 600 VAC auxiliary
contact switch provided.
Amperes
30
60
100
Maximum HP – 3 Phase Volts AC
240
480
600
Enclosure with 3-Pole Switch
Hub Size
Cat. #
10
15
20
11/2"
11/2"
21/2"
20
30
40
25
40
60
Dimensions
In Inches:
Certifications and
Compliances:
• NEC:
Class I, Division 2, Groups B, C, D
• NEMA: 3, 4X, 7 (B, C, D Div. 2), 12
• UL Standard: 508, 1604
• cUL to CSA Standard C22.2 No.213
• IP65
690
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
N2RS303
N2RS603
N2RS1003
GUSC Enclosures
with General Use Snap Switches
Applications:
Size Ranges:
GUSC snap switches are used:
• In a rigid metallic conduit system for
surface mounting adjacent to or remote
from the equipment being controlled
• To prevent arcing of the enclosed
switches from causing ignition of a
specific hazardous atmosphere, or
atmospheres, external to the enclosure
• In industrial areas such as chemical
plants, oil and gas refineries, paint and
varnish manufacturing plants, gasoline
bulk loading terminals, grain elevators,
grain processing industries, coal
processing or handling areas, or metal
handling or finishing areas where the
atmosphere may contain hazardous
gases and/or dust
• In non-hazardous areas where sturdy,
durable enclosures are required
• Hub size – 3/4" (through feed
arrangement)
Features:
2A
Electrical Rating Ranges:
• See below
Ordering Information:
Rating
Cat. #
Style
250 (VAC)
600 (VAC)
Horsepower
Hub Size
GUSC2052 AH
2-Pole
30A
20A
2 HP
3
GUSC2013 AH
3-Pole
30A
20A
2 HP
3
/4"
/4"
2A
• Enclosures are of rugged metal
construction with mounting lugs and
taper tapped hubs with integral
bushings, in a through feed or bottom
feed arrangement, for connection to the
rigid metallic conduit
• Cover is threaded, which provides for
fast and proper assembly
• Provided with a threaded operating shaft
and bushing
• Provision is made to use a padlock with
1
/ 4" hasp, to lock the operating lever
in an "ON" or "OFF" position
• Body and cover threads treated with
lubricant at factory to provide
raintightness
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 7CD, 9EFG, 12
Dimensions
In Inches:
Certifications and
Compliances:
• NEC/CEC:
Class I, Div. 1 & 2, Groups C, D
Class II, Div. 1, Groups E, F, G
Class II, Div. 2, Groups F, G
Class III
• NEMA/EEMAC: 3, 7CD, 9EFG, 12
• UL Standard: 1203
• CSA Standard: C22.2, No. 30
Dimensions are approximate, not for construction purposes.
Type
Standard Materials:
•
•
•
•
a
b
c
d
e
f
Through Feed Hubs – Fig. 1
2, 3-Pole
Size
63/ 16
61/ 16
47/ 8
41/ 8
53/ 8
3
Two Hubs at Bottom – Fig. 2
2, 3-Pole
57/ 16
63/ 8
47/ 8
41/ 8
53/ 8
3
/8
g
21/ 4
Body – Feraloy® iron alloy
Cover – copper-free aluminum
Shaft – stainless steel
Shaft bushing – stainless steel
Standard Finishes:
• Feraloy iron alloy – electrogalvanized and
aluminum acrylic paint
• Copper-free aluminum – natural
• Stainless steel – natural
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
691
2A
FSPC Enclosures
Cl. I, Div. 1 & 2, Groups A†, B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 7A†BCD, 9EFG, 12
with General Use Snap Switches
Applications:
Standard Materials:
FSPC snap switches are installed in a rigid
metallic conduit system for surface
mounting adjacent to or remote from
equipment being controlled and are used:
• To prevent arcing of enclosed switch
from causing ignition of a specific
hazardous atmosphere or atmospheres
external to the enclosure
• In industrial areas such as chemical
plants, oil and gas refineries, paint and
varnish manufacturing plants, gasoline
bulk loading terminals, grain elevators,
grain processing industries, coal
processing or handling areas, or metal
handling or finishing areas where
atmosphere may contain hazardous
gases and/or dust
• In non-hazardous areas where sturdy,
durable enclosures are required
•
•
•
•
2A
Features:
• Rugged cast metal enclosure with
mounting lugs and taper tapped hubs
with integral bushings, in a through feed
arrangement.
• Threaded cover to provide fast, proper
assembly and easier maintenance.
• Journalled type operating shaft – close
tolerance fit for flametightness.
• Body and cover threads treated with
lubricant at factory to provide
raintightness.
Body – Feraloy® iron alloy
Cover – copper-free aluminum
Shaft – stainless steel
Bushing – stainless steel
Standard Finishes:
• Feraloy iron alloy – electrogalvanized
and aluminum acrylic paint
• Copper-free aluminum – natural
• Stainless steel – natural
Ordering Information:
Switch Information
Hub Size
Style
Amperes
120VAC§
/4
3
/4
3
/4
3
/4
1-pole
2-pole
3-pole
3-way
20
20
‡
20
3
Enclosure with Switch
277VAC§
Cat. #
Cat. # †
20
20
‡
20
FSPC21
FSPC22
FSPC230
FSPC23
FSPC216
FSPC226
FSPC2306
FSPC236
Dimensions
In Inches:
Certifications and
Compliances:
• NEC:
FSPC 21 series –
Class I, Divisions 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• NEMA: 3, 7CD, 9EFG, 12
• NEC:
FSPC 216 series –
Class I, Divisions 1 & 2, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• NEMA: 3, 7ABCD, 9EFG, 12
• UL Standard: 1203
• CEC:
FSPC 216 series –
Class I, Divisions 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• Encl. 3, 5
• CSA Standard C22.2, No. 30
Dimensions are approximate, not for construction purposes.
†Suitable for Groups A & B usage.
‡30A, 250 VAC; 20A, 600 VAC.
§See pages 694–695 for AC-rated switch information.
692
www.crouse-hinds.com
US: 1-866-764-5454
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
Cl. I, Zone 1 & 2 Ex de IIC T6
cCSAus Certified
Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1 & 2 AEx de IIC T6
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Light Switch
2A
Applications:
GHG273 series of switches are used:
• To prevent arcing of enclosed switch
from causing ignition of a specific
hazardous atmosphere external to the
enclosure
• In Division 2, Zone 1 and Zone 2
industrial areas such as: chemical plants,
oil and gas refineries, paint and varnish
manufacturing plants, gasoline bulk
loading terminals, grain elevators and
processing industries, coal processing or
handling areas, or finishing areas where
atmosphere may contain hazardous
gases and/or dust
• In non-hazardous areas where sturdy,
durable enclosures are required for both
indoor and outdoor installations of light
switches
Ordering Information
•
•
•
•
Cat. #
•
•
•
•
Small and compact in design.
Large grounding plate.
Captive cover screws.
Protective collar for inadvertent
operation.
Large actuator surface allows for
operation while wearing work gloves.
Labyrinth seal to guarantee the degree
of protection IP66.
The toggle has a luminescent label to
locate switch in dark areas.
Cable entry from the top is made
possible by turning the base.
Contact Arrangement Description
Entry Size
GHG 273 2000 L0005
GHG 273 2000 L0006
2-pole
2-pole
1 x 1/2" NPT
1 x 3/4" NPT
GHG 273 6000 L0001
GHG 273 6000 L0002
3-way
3-way
1 x 1/2" NPT
1 x 3/4" NPT
2A
Features:
Dimensions
In Inches:
Certifications and
Compliances:
•
•
•
•
•
•
•
•
cCSAus Listed
Class I, Division 2, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 1, Groups F, G
Class I, Zone 1 & 2, EEx de IIC T6
Class I, Zone 1 & 2, AEx de IIC T6
Class I, Zone 1 & 2, Ex de IIC T6
PTB Certificate of Conformity
Ex-91.C.1017
• IP66
Standard Materials:
• Body and cover – low temperature,
impact-resistant thermoplastic
• Shaft and screws – stainless steel
• Grounding plate – brass
Dimensions are approximate, not for construction purposes.
Standard Finishes:
• Thermoplastic – natural
• Stainless steel – natural
• Brass – nickel plate
Electrical Ratings:
Voltage
Current
250VAC
16 Amps
50 / 60 Hz
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
693
Cl. I, Div. 1 & 2, Groups B*, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 7B*CD, 9EFG, 12
EDS and EFD Enclosures
2A
with General Use Snap Switches
Front Operated
Applications:
Options:
EDS and EFD enclosures are installed in a
rigid metallic conduit system for surface
mounting adjacent to or remote from
equipment being controlled and are used:
• To prevent arcing of enclosed switch
from causing ignition of a specific
hazardous atmosphere or atmospheres
external to the enclosure
• In industrial areas such as chemical
plants, oil and gas refineries, paint and
varnish manufacturing plants, gasoline
bulk loading terminals, grain elevators,
grain processing industries, coal
processing or handling areas, or metal
handling or finishing areas where
atmosphere may contain hazardous
gases and/or dust
• In non-hazardous areas where sturdy,
durable enclosures are required
Description
• Two or three gang bodies can be supplied with
combinations of devices listed for one gang
enclosures – Refer to modular listing, section 4C
2A
Features:
• Small and compact in design.
• Used with snap switches.
• Mounting lugs and taper tapped hubs
with integral bushings.
• Large machine screws for fastening
covers to bodies.
• Lockout hole for padlock having 1/4" hasp
is provided.
• Threaded type shafts and bushings are
used to insure flame tightness.
GB
• Bodies and Covers: copper-free aluminum ................
SA
• Flush wall mounting cover with 1/2" overhang – single
gang only – dull black instrument finish ...................... S173
EDS Enclosed
Snap Switch
Electrical Ratings
Complies with U.L. snap switch test requirements as follows:
Type of Test
AC-Rated (only) Switch
Overload
Rated Amp. +380%
Power Factor .40 – .50
100 cycles, 6 – 10 cycles per minute
Non-Inductive
Endurance
10,000 cycles, 18 – 24 cycles per minute at rated current – .98
min. P.F.
Inductive Endurance
10,000 cycles, 18 – 24 cycles per minute – .75 – .80 P.F.
Tungsten Filament Lamp 10,000 cycles, 6 – 10 cycles per minute at rated current and 120
volts
Endurance
Temperature Rise
Not to exceed 30°C
Dielectric Withstand
1500 volts
Dimensions
In Inches:
• NEC/CEC:
Class I, Divisions 1 & 2, Groups B*, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• NEMA/EEMAC: 3, 7B*CD, 9EFG, 12
• UL Standard: 1203
• CSA Standard: C22.2 No. 30
Standard Materials:
Standard Finishes:
• Feraloy iron alloy – electrogalvanized and
aluminum acrylic paint
• Stainless steel – natural
Dimensions are approximate, not for construction purposes.
Hub Size
3
/4
1
Dim. "h"
/8
1
7
Dim. "I"
/16
/16
13
15
*Class I, Group B:
All units listed on this page can be modified for Class I, Group B usage. Add suffix GB to the catalog number. Example: EDS2129-GB.
Seals must be installed within 11/ 2" of each conduit opening in Division 1.
694
www.crouse-hinds.com
US: 1-866-764-5454
Suffix
• Class I Group B, NEMA 7B – see listing pages ..........
Certifications and
Compliances:
• Bodies and covers – Feraloy® iron alloy
• Shafts – stainless steel
• Shaft bushings – stainless steel
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
EDS and EFD Enclosures
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Cl. I, Div. 1 & 2, Groups B*, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 7B*CD, 9EFG, 12
with General Use Snap Switches
Front Operated
Dead end
2A
Through feed
Ordering Information:
Amperes§
Single Gang
Through Feed
Cat. #
Two Gang
Style
120VAC
277VAC
/4
/4
3
/4
3
/4
3
/4
1-pole
2-pole
3-pole
3-way
4-way
20
20
‡✪
20
20
20
20
‡
20
20
EDS2129
EDS218
EDS2123
EDS2130
EDS2140
EDSC2129†
EDSC218†
EDSC2123
EDSC2130
EDSC2140
Replacement
Switch
SW5
SW6
0206500
SW7
SW8
1
1
1
1
1-pole
2-pole
3-pole
3-way
20
20
‡✪
20
20
20
‡
20
EDS3129
EDS318
EDS3123
EDS3130
EDSC3129†
EDSC318†
EDSC3123
EDSC3130
SW5
SW6
0206500
SW7
EDS3229
EDS328
1
1
1
1
4-way
1-pole
2-pole
3-way
20
30
30
30
20
30
30
30
EDS3140
EFD3591
EFD3593
EFD3594
EDSC3140
EFDC3591†
EFDC3593†
EFDC3594
SW8
AH3991*
AH3992*
AH3993*
EDS3240
EFD3691
3
3
✪
✪
✪
■
Dead End
Cat. #
Through Feed
Cat. #
EDS2229
EDSC2229†
EDSC228†
EDSC2223
EDSC2230
EDSC2240
EDS2230
EDS3230
EFD3694
2A
Hub Size
Dead End
Cat. #
EDSC3229†
EDSC328†
EDSC3223
EDSC3230
EDSC3240
EFDC3691†
EFDC3693†
EFDC3694
*Class I, Group B:
All units listed on this page can be modified for Class I, Group B usage. Add suffix GB to the catalog number. Example: EDS2129-GB.
Seals must be installed within 11/ 2" of each conduit opening in Division 1.
†ON-OFF standard marking for 1-pole and 2-pole units
‡15A, 125 VAC; 10A, 250 VAC
§See table on pages 694–695 for AC-rated switch information.
■Combinations of switches can be furnished.
*Purchase from Eaton's Wiring Devices.
✪ Not factory sealed.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
695
2A
WST Enclosed Switches
NEMA 3R, 4, 12
Wet Locations
Watertight
Heavy Duty
30, 60, 100 Amp
Applications:
Options:
WST heavy duty enclosed switches are
used in conduit systems:
• As a means of disconnecting motors,
lighting and power circuits. A fusible type
switch, when used, also provides for
short circuit protection
• Indoors or outdoors in industrial areas,
subways, railroad facilities or any other
area that is subjected to dust, dirt,
chemical vapors or moisture (rain or
hosing)
• Either pole-mounted or on flat surfaces
The following special options are available
by adding suffix Cat. No.:
Description
Suffix
• Auxiliary switch, 600VAC-DC
heavy duty pushbutton station
rating, can be supplied, and its
contacts will close after switch
contacts close and open before
switch opens.................................. S483
2A
Features:
• Enclosure, handle and other exterior
parts are lightweight and corrosion
resistant.
• Insulated – groundable type terminal
block for grounded or ungrounded
neutral supplied.
• Mounting lugs may be rotated 90
degrees or moved to the vertical
centerline position for pole-mounting.
• Side hinged cover is retained in a closed
position by compression spring drawpull catches, which permits the opening
or closing of the cover without having to
use any tools. Lower cover latch is
equipped for padlocking.
• The cover is interlocked with the body
and operating mechanism to prevent the
opening of the enclosure, except when
the switch is in the "OFF" position.
• The operating handle may be padlocked
in the "ON" or "OFF" position, thereby
preventing unauthorized operation of the
switch and/or opening of the enclosure.
Up to three padlocks may be used.
• Switches are NEMA type HD heavy duty
with visible blades, a quick make-andbreak mechanism with reinforced,
positive pressure-type blade and jaw
construction. Fusible types have fuse
clips with steel reinforcing springs of
positive pressure type. Pressure
connectors are used for wire connection.
Certifications and
Compliances:
• NEMA: 3R, 4, 12
• UL Standard: 98
• CSA Standard: C22.2 Nos. 4 & 14
Size Ranges:
• Conduit openings for 1" – 11/ 2" inclusive
are arranged for through feed. Removal
of the threaded bushings permits use of
the next larger conduit size.
• Other sizes and arrangements are
available. Detailed information on
request.
WST shown open
Electrical Rating Ranges:
• 2 and 3-pole; fusible or non-fusible;
240VAC, 600VAC and 250VDC
• 30, 60 and 100 amperes
• 3 to 75 hp
Ordering Information:
240VAC
250VDC
600VAC
240VAC
600VAC/250VDC
Cat. #
3
10
15
5
10
20
10
25
40
WST30254
WST60254
WST10254
3-Pole No Fuse
1
30
11/ 4
60
11/ 2
100
71/ 2
15
30
5
10
20
20
50
75
WST30354
WST60354
WST10354
2-Pole Fusible†
1
30
11/ 4
60
11/ 2
100
3
10
15
5
10
20
10
25
40
WST3025‡
WST6025‡
WST10025‡
3-Pole Fusible†
1
30
11/ 4
60
11/ 2
100
71/ 2
15
30
5
10
20
20
50
75
WST3035‡
WST6035‡
WST10035‡
Conduit
Amps
Opening
2-Pole No Fuse
1
30
11/ 4
60
11/ 2
100
Standard HP Rating
†Cartridge fuses are not included.
‡Arranged for NEC Class H fuses. May be field converted to NEC Class J fuses.
Approximate Dimensions
Dimensions
Amps
30
60
100
In Inches:
a
b
c
d
69/16
69/16
99/16
201/16
201/16
265/16
113/4
123/4
147/8
71/4
71/4
81/4
Standard Materials:
• Enclosure – copper-free aluminum
• Operating handle – copper-free
aluminum
• Other exterior parts – stainless steel
Standard Finishes:
• Copper-free aluminum – natural
• Stainless steel – natural
696
www.crouse-hinds.com
US: 1-866-764-5454
Dimensions are approximate, not for construction
purposes.
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
2A
Cl. I, Div. 2, Groups B, C, D
NEMA 3, 12
Raintight
W2ST Enclosed Switches
Heavy Duty
30, 60, 100 Amp
Applications:
Standard Materials:
Dimensions
W2ST Factory Sealed Industrial Control
Switches are used:
• In hazardous areas rated Class I,
Division 2, Groups B, C and D
• In a rigid metallic conduit or cable
system
• For surface or flush mounting adjacent
to or remote from equipment being
controlled
• In industrial applications such as
chemical plants, wastewater treatment
plants, oil and gas refineries, steel mills
or any other areas where atmospheres
may contain hazardous gases
• When controlling motors, pumps, valves,
lighting and other circuits
• Enclosure and operating handle –
copper-free aluminum
• Exterior hardware – stainless steel
In Inches:
Options:
Description
Suffix
Auxiliary switch, factory sealed
10A, 600 VAC .................................... S483
Electrical Rating Ranges:
•
•
•
•
3-Pole Switch, No Fuse
30, 60 and 100 amperes
3 to 60 HP
600 VAC
Ordering Information:
Features:
Amp
Switch
Cat. #
30
60
100
3-pole, No Fuse
3-pole, No Fuse
3-pole, No Fuse
W2ST30354
W2ST60354
W2ST10354
a
69/16
b
c
d
201/16
113/4
71/4
2A
• Enclosed devices are unfused, factory
sealed motor circuit switches
• Exceeds NEC® wiring end room
requirements for ease of wiring
• RSWP factory sealed industrial control
switch, no external seals are required
• The cover is interlocked with the body
and operating mechanism to prevent the
opening of the enclosure, except when
the switch is in the "OFF" position
• Mounting lugs may be rotated 90° or
moved to the vertical centerline portion
for pole mounting
• Side hinged covers are retained in a
closed position by compression spring
draw-pull catches, which permit the
opening or closing of the cover without
tools
• The switch operating handle may be
padlocked in the "ON" or "OFF" position
with up to three padlocks
Horsepower Ratings:
Single Phase
W2ST
30A
60A
100A
3 Phase
120V
240V
480V
600V
120V
240V
480V
600V
3
3
5
7.5
7.5
10
20
20
25
25
25
30
7.5
7.5
10
15
15
20
30
30
40
40
40
60
Certifications and
Compliances:
• NEC/CEC:
Class I, Division 2, Groups B, C and D
• Type: 3 and 12
• UL Standard 698
• cUL to CSA Standard C22.2 No. 14
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
697
NEMA Type 3, 4X, 12
Corrosion Resistant
Watertight
Industrial Disconnect Switches
2A
30, 40, 60, and 100 Amp
600VAC
Non-metallic Enclosure
Applications:
Standard Materials:
• Used in manual "ON" and "OFF" control
of single-phase or three-phase AC
motors where overload protection is not
required or is provided separately.
• Meet NEC Article 430 requirements for a
separate disconnect means within sight
of all motor loads.
• Offers the ability to lock directly wired
motor loads in the "OFF" position to
comply with OSHA lockout/tagout
requirements.
• Meets stringent hosedown requirements.
•
•
•
•
•
•
Enclosure – VALOX® thermoplastic
Enclosure Gasket – Neoprene
Handle – Impact-resistant Thermoplastic
Cover Screws – Stainless Steel
Screw Assembly Inserts – Brass
Conduit Entries – See Table 1*
2A
Features:
• Enclosures are constructed from high
impact thermoplastic, providing superior
durability and corrosion resistance.
• Enclosure designed with tapered edges
to keep liquids away from cover
opening.
• Large pistol-grip handle provides easy
gripping even with gloved hands.
• Lockable handle meets OSHA lockout/
tagout requirements. Handles can be
locked in the "OFF" position.
• Hidden hinge cover opens to 145°,
making installation and maintenance
quick and easy.
• Formed-in-place continuous gasket
ensures NEMA 4X full perimeter sealing.
• Captive cover mounting screws.
• Brass enclosure assembly cover screw
inserts allow for higher torque and
prevent stripping.
Certifications and
Compliances:
All units
• cUL
• NEMA Type 3, 4X, 12
Non-fused Units
• UL 508 – 40 & 60 amp
• UL 98 – 100 amp
Fused Units
• UL 98 – Enclosed Switch
Ordering Information
Cat. #
Description
NRS30
40A, 600V, no auxiliary contacts
NRS30AX
40A, 600V, with auxiliary contacts
NRS30 FS
30A, 600V, with fusible switch for short circuit protection
NRS30AX FS
30A, 600V, with auxiliary contacts and fusible switch for
short circuit protection
NRS60
60A, 600V, no auxiliary contacts
NRS60AX
60A, 600V, with auxiliary contacts
NRS60FS
60A, 600V, with fusible switch for short circuit protection
NRS60AX FS
60A, 600V, with auxiliary contacts and fusible switch for
short circuit protection
NRS100
100A, 600V, no auxiliary contacts
NRS100AX
100A, 600V, with auxiliary contacts
NRS100 FS
100A, 600V, with fusible switch for short circuit protection
NRS100AX FS
100A, 600V, with auxiliary contacts and fusible switch for
short circuit protection
NRS K1
40A - 100A nonfused auxiliary contact kit
NRS K2
60A - 100A fused auxiliary contact kit
NRS K3
30A fused auxiliary contact kit
Options:
• Auxiliary contacts for use with pilot light
of PLC. 10A 600VAC 1 NO. & 1 N.C.
Consult Factory.
*Hubs must be ordered separately. See Table 1.
VALOX® is a registered trademark of General Electric Co.
698
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
Industrial Disconnect Switches
2A
NEMA Type 3, 4X, 12
Corrosion Resistant
Watertight
30, 40, 60, and 100 Amp
600VAC
Non-metallic Enclosure
Electrical Rating Ranges:
Horsepower Ratings:
Single Phase
Three Phase
Switches
120V
240V
208V
240V
480V
600V
40A Nonfused
60A Nonfused
100A Nonfused
30A Fused
60A Fused
100A Fused
1
2
5
2
–
–
5
7.5
15
3
–
–
10
15
25
7.5
15
25
10
15
30
7.5
15
30
20
30
50
15
30
60
25
30
50
20
50
75
Dimensions
In Inches:
Enclosure Type
40 Amp Nonfused
60 Amp Nonfused
100 Amp Nonfused
30 Amp Fused
60 Amp Fused
100 Amp Fused
A
B
C
D
E
F
6.0
8.0
10.0
10.0
14.0
14.0
6.0
6.0
8.0
8.0
12.0
12.0
5.9
5.9
7.9
7.9
7.9
7.9
8.1
8.1
10.1
10.1
10.1
10.1
6.75
8.75
10.75
10.75
14.75
14.75
4.0
4.0
6.0
6.0
8.0
8.0
2A
Table 1 - Conduit Entries
Ordering Information
Krydon®
Cat. #
Size
Myers™ Zinc
Cat. #
Size
Myers™ Stainless Steel
Cat. #
NHUB1
NHUB2
NHUB3
NHUB4
NHUB5
/2"
3
/4"
1"
11/4"
11/2"
STG
STG
STG
STG
STG
/2"
3
/4"
1"
11/4"
11/2"
SSTG
SSTG
SSTG
SSTG
SSTG
1
1
2
3
4
5
www.crouse-hinds.com
1
US: 1-866-764-5454
CAN: 1-800-265-0502
1
2
3
4
5
Size
/2"
/4"
1"
11/4"
11/2"
1
3
Copyright© 2013 Eaton’s Crouse-Hinds Business
699
2A
NEMA 3R
Manual Contactors
AC Only, Full Voltage
30A/40A/60A 600VAC
Without Overload Protection
Applications:
Manual Contactors are used:
• For manual starting of motors up to 30
HP
• In damp or wet locations
Features:
• Compact enclosure meets NEMA 3R
requirements
• Can be padlocked to help conform to
OSHA lockout requirements
• Grounding terminal provides ground for
box and cover
• Enclosed switch body does not expose
contacts
• Double break butt-type silver alloy
contacts provide long life
• Two 1/2", 3/4", 1" knockouts on bottom
2A
Certifications and
Compliances:
Ordering Information:
Description
Amps
600V
Horsepower
480/
120V 240V 600V
Switch
Cat. #
Switch &
Enclosure
Cat. #
2 pole with screw terminals
30
2
5
7.5
6810U
6810W
3 pole with screw terminals
30
3
7.5
15
7810UD 7810WD
2 pole with screw & clamp terminals
40
3
5
15
MC240C MC240C-3
2 pole with box lug terminals
40
3
5
15
MC240L MC240L-3
2 pole with box lug terminals
60
3
5
15
MC260L MC260L-3
3 pole with screw & clamp terminals
40
3
7.5
15 / 20 MC340C MC340C-3
Standard Materials:
3 pole with box lug terminals
40
3
7.5
15 / 20 MC340L MC340L-3
• .060" thick steel enclosure
3 pole with box lug terminals
60
3
7.5
25 / 30 MC360L MC360L-3
• UL 508
• CSA Standard: C22.2 No. 14
• NEMA 3R
Dimensions
Standard Finishes:
In Inches:
6810 / 7810 Series:
• Gray baked enamel finish
MC Series:
• Polyester urethane
Electrical Rating Ranges:
• 30A/40A/60A 600VAC, two pole, single
phase
• 30A/40A/60A 600VAC, three pole,
polyphase
700
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
NST Disconnect Switches and Enclosures
600VAC/250VDC Heavy Duty
Applications:
Options:
• NST disconnect switches are for use in
disconnecting motor, lighting and other
circuits.
Description
Suffix
• Auxiliary switch, 600 VAC-DC
heavy duty pushbutton station
rating, can be supplied. Its
contacts will close after switch
contacts close and open before
switch opens................................ S483*
• Hubs (see "Note on Hubs") –
see page 677
• Grounding plate or bushing –
see page 677
Features:
• Enclosures are made of Krydon®, Eaton's
Crouse-Hinds' high impact strength
fiberglass-reinforced polyester material
having excellent corrosion resistance
and stability to heat.
• Unitized, strong and durable enclosure
construction provides longer service life
for equipment.
• Enclosure has hinged access door which
opens 160° for easy wiring and
maintenance. Three screws for door
frame are hidden behind access door.
• Access door may be padlocked to
prevent unauthorized access.
2A
Corrosion-Resistant
Dust-tight
Watertight
Weatherproof
NEMA 3, 4X, 12
2A
Certifications and
Compliances:
Disconnect switch with built-in Krydon
material handle
• NEMA: 3, 4X and 12
• UL Standard: 98
• CSA Standard: C22.2 No. 4
Electrical Rating Ranges:
• 240 VAC/250 VDC & 600 VAC
• 30, 60, 100 and 200 amp
Ordering Information:
To order an enclosure complete with disconnect switch, insert the
manufacturer’s symbol in the designated positions of the catalog
number. Symbols are shown in the footnotes. Enclosures only can
be ordered. Select from the listings below.
Max HP Rating
Enclosure
DC using 2
poles only
AC Polyphase
250V Max.
With Switch
240VAC/250VDC
Cat. #
With Switch
600VAC
Cat. #
Without
Switch
Cat. #
20
40
50
100
5
10
20
40
NST1018F ➀30320
NST1018F ➀60320
NST1426F ➀10320
NST1426F2 ➀20320†
NST1018F ➀30360
NST1018F ➀60360
NST1426F ➀10360
NST1426F2 ➀20360†
NST1018F ➀
NST1018F ➀
NST1426F ➀
NST1426F2 ➀†
20
40
50
100
5
10
20
40
NST1018F ➀30321
NST1018F ➀60321
NST1426F ➀10321
NST1426F2 ➀20321†
NST1018F ➀30361
NST1018F ➀60361
NST1426F ➀10361
NST1426F2 ➀20361†
NST1018F ➀
NST1018F ➀
NST1426F ➀
NST1426F2 ➀†
Amp
Rating 200/240V
Non-Fusible
30
71/2
60
15
100
30
200
50
440/480V
550/600V
15
30
50
125
Fusible‡
30
60
100
200
15
30
50
125
71/2
15
30
50
➀ Disconnect Switches:
Manufacturer
General Electric
Square D
Cutler-Hammer
Symbol
Switch Type
G
D
W
Type QMW
Class 9422
Type DS
NOTE ON HUBS: The following number and sizes of hubs (not mounted) are included when
disconnect switches are ordered complete. If enclosures only are ordered, hubs must be
ordered separately (see "Options").
Switch Size
30
60
100
200
Number Included
Hub Size
2
2
2
2
3
/4
11/4
2
21/2
*For Square D switches only.
†For General Electric switches only. Accommodates Class J fuses only. Not available with Cutler-Hammer "W" switch.
‡Fuse clips are arranged for Class H fuses and field modifiable for Class J fuses. For Class R fuses, consult Eaton's Crouse-Hinds.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
701
NST Disconnect Switches and Enclosures
2A
Corrosion-Resistant
Dust-tight
Watertight
Weatherproof
NEMA 3, 4X, 12
600VAC/250VDC Heavy Duty
Dimensions*
In Inches:
2A
NMC, NCB & NST
Cat. #
Outside Dimensions
l
w
d
Mounting Dimensions
mw
ml
Door Opening Dimensions
dl
dw
NST1018
NST1426
1913/32
2713/32
823/32
923/32
77/8
117/8
167/8
2311/16
1113/32
1513/32
193/8
271/4
*Dimensions are approximate, not to be used for construction purposes.
702
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
511/16
911/16
3A
Instruments
Hazardous
Description
Page No.
Clocks
TCH
see page 711
Telephones
ETW
Ex-ResistTel, FernTel IP
see page 712
see page 713
Thermostats
HRC
see page 709
Heaters
EXH
XC
see pages 704–705
see pages 707–708
3A
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
703
3A
EXH Series Explosionproof
Electric Air Heaters
Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
NEMA 7CD, 9EFG
Explosionproof
Dust-Ignitionproof
Applications:
EXH explosionproof electric heaters are
used:
• In areas made hazardous by the
presence of flammable gases and
vapors, and combustible dusts
• For rugged locations including: oil
refineries, petrochemical plants, rigs,
pumping stations, turbine compressors,
pulp and paper mills, coal mines, grain
elevators, etc.
• In areas where flammable vapors or
gases or highly combustible dusts may
be present due to accidental or
abnormal conditions
• For standby heat to prevent process
heat loss, or for personnel comfort
during maintenance/repair operations
3A
Features:
• Split fan guard for easy access to fan
• Compact design makes handling during
installation easy
• Evacuated cores heat up quickly with
even heat distribution
• Larger models offer greater kilowatt
range providing more economical means
to heat large areas
• Permanently sealed cores improve
reliability and make field servicing easier
• Control box provides easy access for
installation and maintenance
Certifications and
Compliances:
•
•
•
•
•
•
Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
NEMA: 7CD, 9EFG
UL Standard: 823
CSA Standard: C22.2 Nos. 25, 30, 46
Heater shown has optional built-in thermostat.
Options:
The following special options are available:
Description
Suffix
Built-in disconnect switch ................................................................................................
D
Built-in pilot light ..............................................................................................................
P
3-way switch ....................................................................................................................
S
Built-in thermostat ............................................................................................................
T
Built-in HRC1 explosionproof thermostat ........................................................................ HRC
Accessories:
• Basic mounting kit – suitable for applications where the support arm can be bolted or
welded directly to structural steel or concrete.
Cat. # BMK-EXH5 (insert fan size: 12, 16 or 20)
• Wall mounting kit – suitable for mounting on Z sections.
Cat. # WMK-EXH5 (insert fan size: 12, 16 or 20)
• Hanging mounting kit – simple and economical if adequate overhead structure exists.
Requires 1/ 2" pipe, cut and threaded — not supplied.
Cat. # HMK-EXH5
• Swivel hanging mount kit – swivels 360°. Requires 1/2" pipe, cut and threaded – not
supplied.
Cat. # SHMK-EXH5 (insert fan size: 12, 16 or 20)
• Pipe mounting kit – useful in buildings with insufficient strength to use other types of
mounts. requires 3" pipe.
Cat. # PMKEXH5 (insert fan size: 12, 16 or 20)
Standard Materials and
Finishes:
• Fan – Aluminum blade; steel spider and
hub with 5/8 in. (15.875 mm.) bore
• Core – Steel with integral aluminum fins,
vacuum charged and hermetically sealed
• Heating Elements – Three long life, low
watt-density, high grade metal sheathed
elements
• Heat Transfer Fluid – Long life
formulated ethylene glycol and water,
freeze protected to –49°F (–45°C)
• Cabinet Material – 14 gauge (0.075 in.)
(1.90 mm) steel; epoxy coated with 5
stage pre-treatment including iron
phosphate
• Conduit Material – Heavy walled, 0.122
in (3.1 mm.) steel cadmium plated
BMK Basic Mounting Kit
SHMK Swivel Hanging
Mounting Kit
WMK Wall Mounting Kit
704
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
HMK Hanging Mounting Kit
PMK Pipe
Mounting Kit
3A
Cl. I, Div. 1 & 2, Groups C, D Explosionproof
Dust-Ignitionproof
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
NEMA 7CD, 9EFG
EXH Series Explosionproof
Electric Air Heaters
Specifications:
EXH512
EXH516
EXH520
3
5
7.5
10
15
20
25
30
35
Maximum Altitude
Nominal kW
(ft.)
(m.)
12,000
3,658
8,000
2,438
10,000
3,048
7,000
2,134
10,000
3,048
7,000
2,134
10,000
3,048
7,000
2,134
6,000
1,829
Air Delivery @70°F
@ 21°C
(CFM)
(m3/hr)
500
850
500
850
850
1444
850
1444
1750
2973
1750
2973
3600
6116
3600
6116
3,950
6,711
Horizontal Throw
(ft.)
(m.)
15
4.6
15
4.6
30
9.1
30
9.1
40
12.2
40
12.2
70
21.3
70
21.3
70
21.3
Max. Mounting Height
(ft.)
(m.)
7
2.1
7
2.1
10
3.0
10
3.0
10
3.0
10
3.0
20
6.1
20
6.1
20
6.1
Motor Power
(HP)
(kW)
1
/2
0.187
1
/2
0.187
1
/2
0.187
1
/2
0.187
1
/2
0.187
1
/2
0.187
1
/2
0.373
1
/2
0.373
1
Fan Diameter
(in.)
(mm.)
12
305
12
305
12
305
12
305
16
406
16
406
20
508
20
508
20
508
Net Weight
(lbs.)
(kg.)
140
63.5
140
63.5
140
63.5
140
63.5
168
76.2
168
76.2
201
91.2
201
91.2
201
91.2
Shipping Weight
(lbs.)
(kg.)
194
88
194
88
194
88
194
88
218
98.9
218
98.9
252
114.3
252
114.3
252
114.3
Motor Type
Explosionproof. Thermally protected. Permanently lubricated ball bearings. 1725 RPM.
Fan Guard
Split design with close wiring spacing. 1/4 in. (6.3mm.) probe will not enter.
Heating Elements
Three long-life, low watt-density, high grade metal-sheathed elements.
Temperature High-Limit
Automatic reset type, snap-action bimetal, open on temperature rise. Rated 100,000 cycles at 10 amps,
handles 0.128 amps.
Control Circuit
120 Volts, 0.128 ams, 15 VA.
Control Transformer
Multi-tap primary, 120V secondary, 50 VA.
Contactor
60 or 100 amp. rated 1,000,000 cycles at maximum capacity, operating at not more than 84% full load. 120V,
15 VA fuse protected coil.
Overpressure Protection
Fusible alloy plug 170 psi (1.17 MPa).
Temperature Code Rating
T3B 165°C (329°F) Class I & II.
Temperature Limitations
Operational; –49°F to 176°F (–45°C to 80°C), short term to 248°F (120°C).
/2
0.373
3A
Dimensions
In Inches:
2.5 - 12.5 - 20.9 - Dim.
Dimension 10 kW 20 kW 35 kW Tolerance ±
A
in.
mm
87/16
215
87/16
215
87/16
215
1
/8
3
B
in.
mm
183/16
462
225/16
566
261/4
667
1
/8
3
C
in.
mm
27
686
31
787
35
889
3
/16
4
D
in.
mm
181/2
470
221/2
572
261/2
674
1
/8
3
E
in.
mm
197/15
494
237/16
596
277/16
697
3
/8
10
F
in.
mm
171/2
444
191/2
495
2113/16
554
5
/16
8
Dimensional tolerances ±1/8" (3.2mm) unless otherwise specified.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
705
Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
NEMA 7CD, 9EFG
EXH Series Explosionproof
Electric Air Heaters
3A
Explosionproof
Dust-Ignitionproof
Ordering Information:
Voltage
Phase
Cat. #
Maximum Total
Current (Amperes)
Temperature Rise
°F
°C
Heat Output
BTU/Hr.
EXH512
3.0
3.0
3.0
3.0
3.0
3.0
3.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
7.5
7.5
7.5
7.5
7.5
7.5
7.5
10.0
10.0
10.0
10.0
10.0
10.0
208
208
240
240
480
480
600
208
208
240
240
480
480
600
208
208
240
240
480
480
600
208
240
240
480
480
600
1
3
1
3
1
3
3
1
3
1
3
1
3
3
1
3
1
3
1
3
3
3
1
3
1
3
3
EXH5-208160-030
EXH5-208360-030
EXH5-240160-030
EXH5-240360-030
EXH5-480160-030
EXH5-480360-030
EXH5-600360-030
EXH5-208160-050
EXH5-208360-050
EXH5-240160-050
EXH5-240360-050
EXH5-480160-050
EXH5-480360-050
EXH5-600360-050
EXH5-208160-075
EXH5-208360-075
EXH5-240160-075
EXH5-240360-075
EXH5-480160-075
EXH5-480360-075
EXH5-600360-075
EXH5-208360-100
EXH5-240160-100*
EXH5-240360-100
EXH5-480160-100
EXH5-480360-100
EXH5-600360-100
14.4
8.3
12.5
7.2
6.3
3.6
2.9
24.0
13.9
20.8
12.0
10.4
6.0
4.8
36.1
20.8
31.3
18.0
15.6
9.0
7.2
27.8
41.7
24.1
20.8
12.0
9.6
11.2
11.2
11.2
11.2
11.2
11.2
11.2
18.6
18.6
18.6
18.6
18.6
18.6
18.6
27.9
27.9
27.9
27.9
27.9
27.9
27.9
37.2
37.2
37.2
37.2
37.2
37.2
6.2
6.2
6.2
6.2
6.2
6.2
6.2
10.3
10.3
10.3
10.3
10.3
10.3
10.3
15.5
15.5
15.5
15.5
15.5
15.5
15.5
20.7
20.7
20.7
20.7
20.7
20.7
10,250
10,250
10,250
10,250
10,250
10,250
10,250
17,100
17,100
17,100
17,100
17,100
17,100
17,100
26,600
26,600
26,600
26,600
26,600
26,600
26,600
34,150
34,150
34,150
34,150
34,150
34,150
EXH516
15.0
15.0
15.0
15.0
20.0
20.0
20.0
240
480
480
600
480
480
600
3
1
3
3
1
3
3
EXH5-240360-150
EXH5-480160-150
EXH5-480360-150
EXH5-600360-150
EXH5-480160-200
EXH5-480360-200
EXH5-600360-200
36.1
31.3
18.0
14.4
41.7
24.1
19.2
27.1
27.1
27.1
27.1
36.1
36.1
36.1
15.1
15.1
15.1
15.1
20.1
20.1
20.1
51,200
51,200
51,200
51,200
68,300
68,300
68,300
EXH520
25.0
25.0
30.0
30.0
35.0
35.0
480
600
480
600
480
600
3
3
3
3
3
3
EXH5-480360-250
EXH5-600360-250
EXH5-480360-300
EXH5-600360-300
EXH5-480360-350
EXH5-600360-350
30.1
24.1
36.1
28.9
42.1
33.7
45.2
45.2
26.4
26.4
30.7
30.7
25.1
25.1
14.6
14.6
17.1
17.1
85,400
85,400
102,360
102,360
119,450
119,450
3A
Nominal
Wattage (kW)
Catalog Number Example:
* Not available with built-in disconnect switch (option D).
706
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
NEC: Cl. I, Div. 1 & 2, Groups B*, C & D
IEC: Cl. I, Zones 1 & 2, Group IIB & H2*
NEMA: 7B*CD
XC Series
Explosionproof Electric Heaters
3A
Applications:
Standard Features:
• Sloped-top cabinet prevents objects that
restrict airflow from being set on top
• Corrosion-resistant design with no
exposed copper or brass – suitable for
H2S environments
• High-velocity airflow heats up area faster
with better heat distribution
• 14-gauge steel cabinet for rugged
reliability
• Short cabinet lengths take up less wall
and floor space
• Optional built-in thermostat (Class I,
Division 1, Groups C & D, and Zone 1,
Group IIB models) reduces field
installation costs
• Incoloy® 840 heating elements have
longer life expectancy
• Radial-embossed aluminum plate fins
warp less for better heat transfer
• Galvanized steel mounting brackets for
quick installation
Certifications and Compliances:
• NEC:
Class I, Divisions 1 & 2, Groups B*, C, D
• IEC:
Class I, Zones 1 & 2, Group IIB + H2*
• NEMA: 7B*CD
• UL Standard: 823
• CSA Standard: C22.2 Nos. 25, 30, 46
• Temperature Code: T2A – 280°C (536°F)
3A
Single phase XC explosionproof electric
heaters are used:
• In areas where flammable liquids, gases
or vapors are present
• For rugged locations including:
– Petroleum refineries, gasoline storage
and dispensing areas
– Wastewater treatment plants
– Areas that use flammable liquids for
cleaning parts in dip tanks
– Petrochemical plants
– Paint spraying areas
– Aircraft hangars and fuel servicing
areas
– Hydrogen fuel cell and battery
storage facilities
– Natural gas plants
• In areas where flammable vapors or
gases may be present due to accidental
or abnormal conditions
• For standby heat to prevent process
heat loss or for personnel comfort during
maintenance/repair operations
Standard Materials and Finishes:
• Heating elements – resistance wire embedded in a magnesium oxide refractory and
sheathed in an Incoloy® 840 tube
• Finned tube assembly – aluminum tube with radial-embossed aluminum plate fins
• Cabinet – 14-gauge (0.075"/1.90 mm) steel, green-gray epoxy powder-coated front and
side panels, galvanized steel back panel
Accessories and Options:
• Built-in thermostat for 120-, 208-, 240-, 277- or 480-volt applications (see ordering
information on next page)
• Remotely mounted HRC85 explosionproof thermostat using Honeywell® control for
45°F– 85°F heating range (order separately)
Specifications:
Nominal kW
Shipping Weight
(lbs.)
(kg)
Enclosures
1.2
1.8
3.6
4.8
7.6
61.3
27.8
61.3
61.3
88.4
104.3
27.8
27.8
40.1
47.3
NEMA Type 7. For dry indoor use only. Do not immerse in water.
Do not store or use in areas exposed to rain or snow.
Mounting Brackets
Two 14-gauge galvanized steel brackets.
Heating Elements
Two Incoloy® 840-sheathed elements.
Optional Built-In
Thermostat
Explosionproof room thermostat with 10 settings.
Cabinet Material
14-gauge (0.075"/1.90 mm) steel. Rear panel is galvanized. Front
and side panels are baked green-gray epoxy powder coated with
five-stage pre-treatment, including iron phosphate.
Temperature Code
Rating
T2A – 280°C (536°F)
Temperature Limitations
Operational
–45°C to 40°C (–49°F to 104°F)
Storage
–45°C to 80°C (–49°F to 176°F)
*Hydrogen applications only apply to heaters without built-in thermostats.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
707
3A
XC Series
Explosionproof Electric Heaters
NEC: Cl. I, Div. 1 & 2, Groups B*, C & D
IEC: Cl. I, Zones 1 & 2, Group IIB & H2*
NEMA: 7B*CD
Ordering Information:
With built-in room thermostat –
Class I, Div. 1 & 2, Groups C & D;
Zones 1 & 2, Group IIB
Without built-in room thermostat –
Class I, Div. 1 & 2, Groups B, C & D;
Zones 1 & 2, Group IIB + H2
3A
Cat. #
Unit
Wattage
(kW)
Unit
Unit
Output
Voltage
(BTU/Hr) (Volts)
Unit
Current
(Amps)
Maximum
Circuit Fuse
(Amps)*
XC
XC
XC
XC
XC
XC
A1
A2
A3
A4
A5
A6
N0
N0
N0
N0
N0
N0
1.2
1.2
1.2
1.2
1.2
1.2
4097
4097
4097
4097
4097
4097
120
208
240
480
600
277
10.0
5.8
5.0
2.5
2.0
4.3
15
15
15
15
15
15
XC
XC
XC
XC
XC
XC
B1
B2
B3
B4
B5
B6
N0
N0
N0
N0
N0
N0
1.8
1.8
1.8
1.8
1.8
1.8
6146
6146
6146
6146
6146
6146
120
208
240
480
600
277
15.0
8.7
7.5
3.8
3.0
6.5
20
15
15
15
15
15
XC
XC
XC
XC
XC
C2
C3
C4
C5
C6
N0
N0
N0
N0
N0
3.6
3.6
3.6
3.6
3.6
12292
12292
12292
12292
12292
208
240
480
600
277
17.3
15.0
7.5
6.0
13.0
20
20
15
15
15
XC
XC
XC
XC
XC
D2
D3
D4
D5
D6
N0
N0
N0
N0
N0
4.8
4.8
4.8
4.8
4.8
16389
16389
16389
16389
16389
208
240
480
600
277
23.1
20.0
10.0
8.0
17.3
25
25
15
15
20
XC
XC
XC
XC
XC
E2
E3
E4
E5
E6
N0
N0
N0
N0
N0
7.6
7.6
7.6
7.6
7.6
25950
25950
25950
25950
25950
208
240
480
600
277
36.5
31.7
15.8
12.7
27.4
40
35
20
15
30
Cat. #
Unit
Unit
Unit
Unit
Wattage Output
Voltage Current
(kW)
(BTU/Hr) (Volts)
(Amps)
Maximum
Circuit Fuse
(Amps)*
XC
XC
XC
XC
XC
A1
A2
A3
A4
A6
B1
B2
B3
B4
B6
1.2
1.2
1.2
1.2
1.2
4097
4097
4097
4097
4097
120
208
240
480
277
10.0
5.8
5.0
2.5
4.3
15
15
15
15
15
XC
XC
XC
XC
XC
B1
B2
B3
B4
B6
B1
B2
B3
B4
B6
1.8
1.8
1.8
1.8
1.8
6146
6146
6146
6146
6146
120
208
240
480
277
15.0
8.7
7.5
3.8
6.5
20
15
15
15
15
XC
XC
XC
XC
C2
C3
C4
C6
B2
B3
B4
B6
3.6
3.6
3.6
3.6
12292
12292
12292
12292
208
240
480
277
17.3
15.0
7.5
13.0
20
20
15
15
XC D3 B3 4.8
XC D4 B4 4.8
XC D6 B6 4.8
16389
16389
16389
240
480
277
20.0
10.0
17.3
25
15
20
XC E4 B4 7.6
25950
480
15.8
20
*Or equivalent breaker as per National Electrical Code and Canadian Electrical Code
1. Remote-mounted explosionproof room thermostats are not suitable for Group B & IIC
applications. Remote contactors are also required on all 600-volt heaters and heaters with a
current draw greater than 22 amps (supplied and installed by others).
2. Remote mounted explosionproof room thermostats suitable for Group B, IIB + H2
applications are a special-order item.
3. Operation at lower than rated voltages will result in reduced kW output and amp draw.
Actual Output (kW) = [(Supply Voltage)2 ÷ (Rated Voltage)2] x Rated Unit Wattage (kW)
Dimensions
In Inches:
Heater kW
Rating
1.2 - 3.6
4.8
7.6
A Dimensions
B Dimensions
37.0" (940mm)
55.125" (1400mm)
65.125" (1654mm)
31.34" (796mm)
49.45" (1256mm)
59.49" (1511mm)
*Hydrogen applications only apply to heaters without built-in thermostats.
708
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
HRC Thermostats with
Honeywell Control
Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 7CD, 9EFG, 12
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
3A
Applications:
HRC thermostats with Honeywell control
are used:
• For heavy duty line voltage thermostats
to control fan coils, fans, motor starters,
valves, contactors, and circulator motors
in heating and/or cooling systems. If
larger motors than listed are to be
controlled, relays or magnetic motor
starters must be interconnected
between motors and thermostats
• In specific hazardous atmospheres such
as encountered in oil refineries, chemical
plants, paint and varnish manufacturing
plants, certain hazardous metal finishing
areas, coal processing locations,
granaries and grain processing plants
Features:
Electrical Rating Ranges:
• 120 / 240 VAC
• 50 / 60 hertz
• Full load current in amperes:
Heating
Cooling
3A
• A heavy duty snap switch is mounted in
the enclosure; the temperature sensitive
element is mounted on the external
surface of the cover and actuates the
switch through a shaft and bearing
mechanism
• An external knob permits temperature
setting within calibrated range; the knob
is removable to prevent unauthorized
adjustment; room ambient is indicated
on thermometer at front
120 VAC
240 VAC
10.2
7.4
6.5
4.0
Ordering Information:
Certifications and
Compliances:
• NEC/CEC:
Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• NEMA/EEMAC: 7CD, 9EFG, 12
• UL Standard: 1203
• CSA Standard: C22.2 No. 30
Temperature
Range
Non-Adjustable Operating Differential
(approx.)
Cat. #†
45 – 85°F
1° F
HRC85
†Furnished with thermostat and thermometer.
Dimensions*
In Inches:
Standard Materials:
• Feraloy® iron alloy
Standard Finishes:
• Electrogalvanzed and aluminum acrylic
paint
Size Ranges:
• Hubs – 3/4" through-feed
*Dimensions are approximate, not for construction purposes.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
709
HRC Bimetal Thermostat
3A
Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
Explosionproof
Dust-Ignitionproof
Applications:
HRC Bimetal Thermostats are used:
• To control heating only, cooling only or
ventilation systems in demanding
industrial environments
• In specific hazardous atmospheres such
as encountered in oil refineries, chemical
plants, paint and varnish manufacturing
plants, coal processing locations, waste
storage facilities, pulp and paper mills,
granaries and grain processing plants or
any other location where specific
explosive gases or dusts are present
3A
Features:
• Bimetal sensing element that is fast
acting, reliable and unaffected by altitude
• Compact, lightweight design makes it
easy to install
• No exposed copper or brass parts for
excellent resistance to corrosion
• Feed-through design for easy installation
• Durable all aluminum exterior
• Available for heating only or heating or
cooling/ventilation applications
Certifications and
Compliances:
Ordering Information
Hub
Size
Description
Cat. #
/4
3
/4
Single Pole, Single Throw (heating only)
Single Pole, Double Throw (heating or cooling/ventilation applications)
HRC1
HRC2
3
Dimensions
In Inches:
• NEC/CEC:
Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2 No. 30
Standard Materials:
• Copper-free aluminum
Standard Finishes:
• Natural
Size Ranges:
• Conduit opening – 3/4" hub
Electrical Ratings:
•
•
•
•
480 VAC max
/ 2 HP @ 120 VAC
1 HP @ 250 VAC
22 amps Res.
1
Temperature Range:
• 36°F to 82°F (2°C to 28°C)
• Temperature differential: 2.5°F (1.5°C)
710
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
TCH Electric Clocks
Explosionproof
Dust-Ignitionproof
Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
Factory-sealed
3A
Applications:
Type TCH electric clocks are used:
• In oil refinery control rooms, hospital
operating rooms, chemical plants, grain
handling and processing plants and
other similar locations where specific
hazardous atmospheres may exist
Features:
• Sheet steel case may be used where
environmental conditions are not severe;
electric motor and connections are
contained in corrosion-resistant
enclosure; dials are 13" in diameter;
reset knob protrudes from bottom of
case
• Disassembly for installation and
maintenance is easily performed; the
motor housing is factory-sealed, with no
external seals required
Sheet Steel Case
Certifications and
Compliances:
Standard Materials:
• Clock body and cover – sheet steel
• Motor housing – copper-free aluminum
Enclosure with Clock
Motor
Hub Size
110 VAC
60 hertz
Self-Starting
Synchronous
(3 Watts)
1"
Style
Cat. #
Enclosing Sheet
Metal Band
Cat. #
With Sheet
Steel Case
Surface Mount
TCH2220
TCH202
3A
Ordering Information:
• NEC:
Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• UL Standard: 1203
Dimensions*
In Inches:
Standard Finishes:
• Aluminum – aluminum acrylic paint
• Sheet steel – baked aluminum enamel
Size Ranges:
• Hubs – 1" through-feed
Electrical Rating Ranges:
• 110VAC, 60 hertz
• Self-starting synchronous motor – 3
watts
Options:
The following special options are available:
Description
Suffix
Sheet metal band notched for
conduit, can be supplied for
enclosing gap between wall surface
See
and back of case
listings
*Dimensions are approximate, not for construction purposes.
Cat. #
a
b
c
TCH2220
17
27/8
37/16
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
711
3A
ETW Telephones
Cl. I, Div. 1 & 2, Groups B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Applications:
ETW series telephones are used:
• For communication in areas which may
be hazardous due to the presence of
flammable gases or vapors, and/or
combustible dusts
• In chemical plants, oil refineries, bulk
loading stations, paint and varnish
manufacturing plants, grain processing
and similar industries
3A
Features:
• Modern styled, pushbutton wall-mount
unit is very rugged in design, suitable for
the harshest industrial applications
• Large, easy to read keyboard allows
gloves-on operation
• Cast copper-free aluminum housing,
with baked on powder coat finish, is
highly resistant to corrosive atmospheres
• Units are tone or pulse compatible and
offer superior audio clarity
• Handset cord features a pin-type
connector for easy field replacement;
handset circuit is intrinsically safe
• Up to ten units can be connected on one
line
ETW401
Certifications and
Compliances:
Ordering Information:
• NEC/CEC:
Class I, Divisions 1 & 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
• UL Standard: 1203, 698
• CSA Standard: C22.2 No. 30
• FCC Approved
Description
Cat. #
Phone w/ handset
Replacement handset (10' cord) ETW
Replacement handset (20' cord) ETW
Phone w/ headset
Phone push-to-talk handset
Replacement headset
Explosionproof ringer
ETW401
ETW:301SC
ETW:301SC 20
ETW401 HS
ETW401 PB
ETW:P7200
ETR1
Standard Materials:
Dimensions
• Enclosure – copper-free aluminum
• Handset – high impact plastic
In Inches:
Standard Finishes:
• Enclosure – baked powder paint (safety
blue)
Accessories:
• A standard volume explosionproof ringer
(ETR1) is available, see page 714 for
listing.
• For locations with a high level of ambient
noise, a louder ringer can be installed.
An ESR bell or ETH horn may be used
by installing an ETC relay between the
telephone line switch and the bell or
horn. The relay coil is energized by the
ringing current and the relay contacts
control a separate power source to the
signal.
Dimensions are approximate, not for construction purposes.
712
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
Ex-ResistTel, FernTel IP
3A
Cl. I, Div. 2, Groups A, B, C, D
NEMA 3, 4X
IP65, 66
Telephones for Hazardous Areas
Ex-ResistTel, FernTel IP - Hazardous Area Communication Series
Applications:
Industrial telephones developed specifically for the harsh and
hazardous environments are found in:
• Oil refineries, petrochemical plants, offshore platforms, marine
applications and industrial manufacturing.
These telephones can handle large temperature differences found
outdoors, high humidity and exposure to sea water, as well as heavy
mechanical wear and tear.
Features:
FernTel IP – Hazardous Voice over Internet Protocol Telephone
• Corrosion resistant polycarbonate housing with ½” NPT conduit
entries and Type 3 (IP65) protection
• Programmable with alphanumeric illuminated display and a
21-piece lighted keypad
• Hermetically sealed non-contact hook sensing switch improves
system reliability
• Captive cover screws prevent loss during installation
• Power supply: PoE (power over ethernet) with no separate power
supply required
• Operating Connection: 10/ 100 BASE-T Ethernet LAN
• Protocoll: H323 and SIP
• Operating Environment from -20°C to +55°C
• Ringer Output: 95dB
Ex-ResistTel
FernTel IP
Certifications and Compliances:
Ex-ResistTel
• Class I, Division 2, Groups A, B, C, D T6
• Type 4X, IP66 to EN 60529
• UL & cUL
• FCC: Parts 15 and 68 hearing aid compatible
• TIA-968-A & CS-03 Part 1
3A
Ex-ResistTel – Hazardous Analog Telephone
• Fully encapsulated electronics in robust glass fiber-reinforced
polymer housing with ½” NPT conduit entries and Type 4X (IP66)
protection
• Programmable with alphanumeric display and a 21-piece stainless
steel lighted keypad
• Hermetically sealed non-contact hook sensing switch improves
system reliability
• Captive cover screws prevent loss during installation
• Ventilation/pressure balancing plug eliminates moisture collection
inside the enclosure
• 10 ringing melodies, maximum 50 directory entries; multiple
languages available
• Operating Environment from -20°C to +40°C
• Ringer output: 90dB; noise suppression: 3dB
FernTel IP
• Class I, Division 2, Groups A, B, C, D T5
• Type 3, IP65 to EN 60529
• UL & cUL
Standard Materials:
• Enclosure – Glass fiber-reinforced polymer (Ex-ResistTel);
Polycarbonate (FernTel IP)
• Keypad, Faceplate, Trip, Armored Cord – 316 SST
Dimensions & Weights:
• Ex-ResistTel – 10.5” x 9” x 5.3”; 12 lbs
• FernTel IP – 12” x 8” x 5”; 5.5 lbs
Ordering Information:
Model
Type
Description
Color
Cat. #
Ex-ResistTel
Analog
Keypad & Display
Black
11286101110
FernTel IP
VoIP
Spiral Cord
Yellow
11241141
FernTel IP
VoIP
Armored Cord
Yellow
11243141
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
713
3A
Cl. I, Div. 1 & 2, Groups B*, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
Telephone Accessories
Power Relay
Features:
• ETC232 power relays are used with ESR
bells and ETH, W2H or WH horns; the
relay coil is energized by the telephone
ringing circuit, and the relay contacts
control the separate 115VAC, 60 hertz
power source
• ETR1 external ringer for ETW401
telephone; for low ambient noise areas,
ring tone level is similar to a general use
telephone; includes a ring detect relay
which is powered by the telephone line
voltage, (maximum 90VAC)
Description Rating
3A
Certifications and
Compliances:
Relay for
Horn Signal
10A 115VAC
60 hertz
• NEC/CEC:
Class I, Division 1 & 2, Groups B*, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2 No. 30
Ringer
Hub
Size Cat. #
/4"
3
ETC232
Description
Normal volume external
ringer for ETW40
telephone
Standard Materials:
• Bodies – copper-free aluminum
• Covers – copper-free aluminum
Standard Finishes:
• Aluminum – baked epoxy powder paint
*For use in Group B hazardous areas, seals must be installed within 11/ 2" of each conduit entrance.
714
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Copyright© 2013 Eaton’s Crouse-Hinds Business
Hub
Size
Cat. #
/ 4"
ETR1
3
Transformers
4A
Description
Page No.
XDT Hazardous Location Dry-Type Transformers
see pages 716–718
4A
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
715
XDT Hazardous Location Dry-Type
Transformers
4A
Cl. I, Div. 2, Groups A, B, C, D NEMA 3R, 4X
Resin Encapsulated Dry-Type Series
Eaton's Crouse-Hinds Hazardous Location Dry-Type Transformers
provide safe and efficient electric power distribution in the most
extreme harsh and hazardous locations.
Applications:
Eaton's Crouse-Hinds Hazardous Location Dry-Type Transformers
are designed to operate where volatile flammable liquids or gases
are handled, processed, or used, and where ignitable concentrations
of gases or vapors are normally prevented by positive mechanical
ventilation, such as:
• Refineries
• Chemical and petrochemical plants
• Mining
• Corrosive process facilities
• Indoor and outdoor industrial applications
4A
Features:
• Resin-encapsulated core-coil assembly for reliable performance in
extreme environments
• NEMA 3R and 4X enclosures provide essential ingress protection
• 180°C insulation system with 115°C winding temperature rise
creates optimal loading capabilities
• Ratings: single phase - 0.5 kVA through 37.5 kVA; three phase 3 kVA through 150 kVA
• Custom configurations available to meet customer specifications
Certifications and Compliances:
•
•
•
•
Class I, Division 2, Groups A, B, C, D
NEMA 3R, 4X
UL Standard 1604
cUL to C22.2 No. 66 and C22.2 No. 213-M1987
Standard Materials:
• Enclosure – painted steel (NEMA 3R) or 316 stainless steel
(NEMA 4X)
• Windings – aluminum or copper
716
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Electrical Ratings:
•
•
•
•
•
•
Single phase: 0.5 to 37.5 kVA
Three phase: 3 to 150 kVA
180°C insulation
115°C winding temperature rise
Frequency: 60 Hz
Impedance: 2 to 5%
Options:
Description
Suffix
NEMA 4X ................................................................................ X
Aluminum windings (three phase only) .................................. AL
Copyright© 2013 Eaton’s Crouse-Hinds Business
XDT Hazardous Location Dry-Type
Transformers
Cl. I, Div. 2, Groups A, B, C, D
4A
NEMA 3R, 4X
Resin Encapsulated Dry-Type Series
Ordering Information - Single Phase:
Primary Voltage
480V
Secondary Voltage
120 / 240V
NEMA
kVA
3R
4X
0.5
XDT1A0A
XDT1A0AX
0.75
XDT1A0B
XDT1A0BX
1
XDT1A1
XDT1A1X
1.5
XDT1A1A
XDT1A1AX
2
XDT1A2
XDT1A2X
3
XDT1A3
XDT1A3X
5
XDT1A5
XDT1A5X
7.5
XDT1A7
XDT1A7X
10
XDT1A10
XDT1A10X
15
XDT1A15
XDT1A15X
25
XDT1A25
XDT1A25X
37.5
XDT1A37
XDT1A37X
4A
Ordering Information - Three Phase:
Primary Voltage
NEMA
kVA
600V
480V
Secondary Voltage
208Y / 120V
240V
208Y / 120V
480Y / 277V
3R
4X
3R
4X
3R
4X
3R
4X
3
XDT3B3
XDT3B3X
XDT3C3
XDT3C3X
XDT3D3
XDT3D3X
XDT3E3
XDT3E3X
6
XDT3B6
XDT3B6X
XDT3C6
XDT3C6X
XDT3D6
XDT3D6X
XDT3E6
XDT3E6X
9
XDT3B9
XDT3B9X
XDT3C9
XDT3C9X
XDT3D9
XDT3D9X
XDT3E9
XDT3E9X
15
XDT3B15
XDT3B15X
XDT3C15
XDT3C15X
XDT3D15
XDT3D15X
XDT3E15
XDT3E15X
30
XDT3B30
XDT3B30X
XDT3C30
XDT3C30X
XDT3D30
XDT3D30X
XDT3E30
XDT3E30X
45
XDT3B45
XDT3B45X
XDT3C45
XDT3C45X
XDT3D45
XDT3D45X
XDT3E45
XDT3E45X
75
XDT3B75
XDT3B75X
XDT3C75
XDT3C75X
XDT3D75
XDT3D75X
XDT3E75
XDT3E75X
112.5
XDT3B112
XDT3B112X
XDT3C112 XDT3C112X
XDT3D112
XDT3D112X
XDT3E112
XDT3E112X
150
XDT3B150
XDT3B150X
XDT3C150 XDT3C150X
XDT3D150
XDT3D150X
XDT3E150
XDT3E150X
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
717
XDT Hazardous Location Dry-Type
Transformers
4A
Cl. I, Div. 2, Groups A, B, C, D NEMA 3R, 4X
Resin Encapsulated Dry-Type Series
Technical Details - Single Phase:
NEMA 3R Painted Steel Enclosure
4A
Single Phase - 480V Primary to 120 / 240V Secondary
kVA
Cat. #
Winding
Height (In.)
Width (In.)
Depth (In.)
Weight (Lbs.)
Frame
Taps
0.5
XDT1A0A
CU
6.5
4.9
4.7
21
57H
None
0.75
XDT1A0B
CU
8.4
6.0
5.5
33
58H
None
1
XDT1A1
CU
8.4
6.0
5.5
35
59H
None
1.5
XDT1A1A
CU
10.5
6.4
6.1
52
67H
None
2
XDT1A2
CU
10.5
6.4
6.1
51
68H
None
3
XDT1A3
AL
14.1
7.8
8.0
79
176H
None
5
XDT1A5
AL
16.0
10.4
9.9
140
177H
None
7.5
XDT1A7
AL
16.0
10.4
9.9
146
178H
None
10
XDT1A10
AL
19.0
13.4
10.5
240
179H
None
15
XDT1A15
AL
19.0
13.4
10.5
260
180H
None
25
XDT1A25
AL
28.5
22.5
14.7
409
300H
None
Technical Details - Three Phase:
NEMA 3R Painted Steel Enclosure
Three Phase - 480V Δ Primary to 208Y / 120V Secondary
kVA
Cat. #
Winding
Height (In.)
Width (In.)
Depth (In.)
Weight (Lbs.)
Frame
Taps
3
XDT3B3
CU
13.4
16.0
3.4
152
201H
2 at -5%
6
XDT3B6
CU
15.9
16.5
9.9
215
200H
2 at -5%
9
XDT3B9
CU
15.9
16.5
9.9
230
103H
2 at -5%
15
XDT3B15
CU
17.4
19.7
10.7
316
95H
2 at +2.5%; 2 at -2.5%
30
XDT3B30
CU
26.6
25.3
12.8
632
243H
2 at +2.5%; 4 at -2.5%
45
XDT3B45
CU
26.5
28.5
14.6
898
244H
2 at +2.5%; 4 at -2.5%
75
XDT3B75
CU
30.8
30.1
15.6
1470
245H
2 at +2.5%; 4 at -2.5%
112.5
XDT3B112
CU
150
XDT3B150
CU
Contact Customer Service
Additional Information and Configurations:
• Contact Customer Service for technical specifications (dimensions, weights, taps, etc.) on all other sizes.
• Special configurations are available on request. Please contact Customer Service for additional details.
718
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business