4C EDS / EFS Series Control Stations FlexStation

advertisement

4C EDS / EFS Series

Control Stations

FlexStation

Control Station Components

Applications:

Five modular components – operators, contact blocks, covers, legend plates, and bodies – are combined to provide a variety of control stations which are:

• For use indoors or outdoors, in areas which are hazardous due to the presence of flammable gases and vapors, or combustible dust.

• Used in conjunction with magnetic starters or contactors for remote control of motors and other electrical apparatus.

• For installation in petroleum refineries, chemical, petrochemical, and other industrial process facilities; grain processing and storage facilities; and other heavy industrial applications where

Class I, Class II, or Class III hazards are present.

Features:

• Momentary contact pushbuttons, maintained contact pushbuttons, and pilots lights offer a choice of functions.

• Selector switches in 2 or 3 position configurations including keyed and spring return options.

• Single-hole, two-hole, and three-hole covers for one, two, or three devices respectively per station.

• Rugged control devices for safe, reliable operation in industrial applications.

• Bodies, with extra room for wire pulling and termination, also include two integral mounting feet for fast, secure installation.

• Bodies have 1 /

2

", 3 /

4

", or 1" dead-end or through-feed conduit hubs with integral bushing for protection of wire insulation.

• Covers and bodies are available in

Feraloy ® or copper-free aluminum for light weight and corrosion resistance.

• DL legend plates have large lettering to give clear indication of device function.

Space is available for field markings.

Certifications and

Compliances:

• NEC

Class I, Division 1 & 2, Groups B*

(Div. 2), C, D

Class II, Division 1 & 2, Groups E, F, G

Class III

• Zone 1 & 2 Group IIB*

• NEMA: 3R, 7B (Div. 2) CD, 9EFG, 12

• UL Standard: 1203

Cl. I, Div. 1 & 2, Groups B (Div. 2 only) C, D

Cl. II, Div. 1 & 2, Groups E, F, G

Cl. III

Zone 1 & 2 Group IIB

NEMA 3R, 7B* (Div. 2) CD, 9 EFG, 12

Standard Materials:

• Bodies, covers –

Feraloy aluminum.

® or copper-free

• Pushbuttons and guards – Type 6 / 6 nylon.

• Operating shafts, bearings – stainless steel.

Standard Finishes:

Feraloy ® iron alloy – electrogalvanized and aluminum acrylic paint.

• Copper-free aluminum – natural.

• Stainless steel – natural.

Dimensions

In Inches:

Options:

Description

Copper-free aluminum bodies and covers

Corro-free™ epoxy finish for use in severely corrosive environments.

FlexStation covers and bodies.

Suffix

SA

S752

Electrical Ratings:

• Pushbuttons and selector switches –

600 VAC heavy duty (NEMA A600).

• Pilot lights – 120 VAC.

514

†Covers have same length and width as back boxes.

*For Class I, Division 1, Group B or Zone 1 Hydrogen applications, use the EFS(C) complete control station catalog numbers see page 528.

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright © 2013 Eaton’s Crouse-Hinds Business

EDS / EFS Series

Control Stations

FlexStation

Control Station Components

Cl. I, Div. 1 & 2, Groups B (Div. 2 only) C, D

Cl. II, Div. 1 & 2, Groups E, F, G

Cl. III

Zone 1 & 2 Group IIB

NEMA 3R, 7B* (Div. 2) CD, 9 EFG, 12

4C

STEP 1 – Select Operator

Pushbutton – front operated, standard black button

Description

Single button for 1 contact block

Single button for 2 contact blocks

Double buttons for 2 contact blocks

Cat. #

DEV11

DEV12

DEV22

  

  

Options Suffix

  

  

  

  

  

Specify color for each pushbutton button (ex: DEV11G, DEV22GR). Color is black if unspecified.

Green button - unmarked

Red button - unmarked

Momentary red mushroom head style (not available with lockout or with DEV22)

Lockout with bar and chain (available on DEV11 and DEV12)

Maintained red mushroom head style (lockout comes standard, do not specify S153; not available on DEV22) (Push to stop only)

G

R

S111

S153

S769

  

Pilot Light – factory sealed, incandescent lamp

  

Description

Pilot light with red jewel

Pilot light with green jewel

Pilot light with amber jewel

Pilot light with clear jewel

Pilot light with blue LED and clear jewel

Options

LED lamps (standard clear jewel with colored lamp)

24 V lamp (not available with transformer feature)

240 / 120 V pilot light transformer

480 / 120 V pilot light transformer

600 / 120 V pilot light transformer

Cat. #

DEV30 J1

DEV30 J3

DEV30 J6

DEV30 J10

DEV30 J11 LED

Suffix

LED

S300

T2

T4

T5

Selector Switch – with standard lockout

Description

2-position (pos. 1 – N.O., pos. 2 – N.C.) for use with 1 or 2 contact blocks

3-position (pos. 1 – N.O., pos. 2 – Open, pos. 3 – N.C.) for use with 1 or 2 contact blocks

3-position (pos. 1 – N.C., pos. 2 – N.O., pos. 3 – N.O. for Switch A)

(pos. 1 – N.O., pos. 2 – N.O., pos. 3 – N.C. for Switch B) for use with 2 contact blocks

Spring return to center from right (For DEV43 or DEV44 only)

Spring return to center from left (For DEV43 or DEV44 only)

Spring return to center from right and left (For DEV43 or DEV44 only)

Key Operated – removable from all positions

Key Operated – removable from left position for DEV42 or from center for DEV43 and DEV44

Key Operated – removable from right position for DEV42 or from left for DEV43 and DEV44

Key Operated – removable from right position for DEV43 and DEV44

*Additional key lock housings available; please contact Customer Service.

Cat. #

DEV42

DEV43

DEV44

Suffix

S634

S635

S842

S847 K1*

S847 K2*

S847 K3*

S847 K4*

STEP 2 – Select Contact Block (if required). For product details see page 571.

Contact Block

Description

Contact block, 1 NO and 1 NC, 10A, 600VAC, A600 rating

  

For additional technical information see page 571.

Cat. #

ESWP126

Note - Each control station will accept a maximum of three contact blocks. Select device operators accordingly. DEV12, DEV22 and DEV44 may not be used on a three-operator (DS443-SA) cover. DEV42 and DEV43 may not be used on a three-operator cover when using them with two contact blocks.

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright © 2014 Eaton’s Crouse-Hinds Business

4C EDS / EFS Series

Control Stations

FlexStation

Control Station Components

Cl. I, Div. 1 & 2, Groups B (Div. 2 only) C, D

Cl. II, Div. 1 & 2, Groups E, F, G

Cl. III

Zone 1 & 2 Group IIB

NEMA 3R, 7B* (Div. 2) CD, 9 EFG, 12

STEP 3 – Select Desired Legend Plates

For use with single hole covers

Cat. # Inscription

For use with 2 or 3 hole covers

Cat. # Inscription Cat. #

DL165

DL186

DL187

DL188

DL189

DL190

DL191

DL192

DL193

DL194

DL195

DL196

DL197

DL198

DL199

DL101

DL128

DL129

DL130

DL132

DL133

DL135

DL136

DL137

DL138

DL139

DL140

DL141

DL142

DL143

DL144

DL148

DL149

Blank

Run-Jog

Hand-Auto

Forward-Reverse

Open-Close

Up-Down

In-Out

Raise-Lower

Start-Stop

Run-Off-Jog

Hand-Off-Auto

For-Off-Rev

Fast-Off-Slow

1-Off-2

Open-Off-Close

Up-Off-Down

Off-On

Auto-Off-Hand

Slow-Fast

Safe-Run

Raise-Off-Lower

Slow-Off-Fast

Odd-Off-Even

Stop-Start

On-Off

Fast-Slow

Local-Remote

Trip-Reset

Auto-Manual

Start-Emer Stop

Alarm-Silence

Maint-Manual

Test-Reset

DL10

DL11

DL12

DL13

DL14

DL15

DL16

DL17

DL18

DL19

DL01

DL02

DL03

DL05

DL06

DL07

DL08

DL09

DL20

DL21

DL22

DL23

DL24

DL25

DL26

DL27

DL28

DL29

DL30

Note: For special markings order DL101-"desired markings" or DL01-"desired markings"

Blank w/no fields

Blank w/single field

Blank w/2 fields

Start

Stop

On

Off

Run

Jog

Trip

Reset

Test

Power On

Hand

Automatic

Emer Stop

Forward

Reverse

Open

Close

Up

Down

In

Out

Raise

Lower

Run-Jog

Hand-Auto

Forward-Reverse

DL86

DL87

DL88

DL89

DL90

DL91

DL92

DL93

DL94

DL95

DL96

DL97

DL98

DL99

DL41

DL42

DL43

DL44

DL46

DL47

DL48

DL49

DL65

DL85

DL32

DL33

DL35

DL36

DL37

DL38

DL39

DL40

STEP 4 – Select Cover

Covers

Description

Blank cover with single hole (Single gang)

Blank cover with 2 holes (Single gang)

Blank cover with 3 holes (To be used with EFD(C)1491-SA, 2491-SA or 3491-SA series of back boxes)

Replacement cover plug for unused device operator openings

Inscription

Open-Close

Up-Down

In-Out

Raise-Lower

Start-Stop

Run-Off-Jog

Hand-Off-Auto

For-Off-Rev

Fast-Off-Slow

1-Off-2

Open-Off-Close

Up-Off-Down

Fast

Slow

Off-On

Auto-Off-Hand

Slow-Fast

Safe

Safe-Run

Raise-Off-Lower

Slow-Off-Fast

Odd-Off-Even

Stop-Start

On-Off

Fast-Slow

Local-Remote

Trip-Reset

Auto-Manual

Start-Emer Stop

Alarm-Silence

Maint-Manual

Test-Reset

Cat. #

DS441

DS442

DS443 SA

206765

Options:

Aluminum body (mandatory suffix on DS443 must be included in catalog number)

Exterior epoxy powder coat finish

Interior & exterior epoxy powder coat finish. Not available on three operator cover (DS443-SA)

Suffix

SA

S752

S753

516 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright © 2013 Eaton’s Crouse-Hinds Business

EDS / EFS Series

Control Stations

FlexStation

Control Station Components

Cl. I, Div. 1 & 2, Groups B (Div. 2 only) C, D

Cl. II, Div. 1 & 2, Groups E, F, G

Cl. III

Zone 1 & 2 Group IIB

NEMA 3R, 7B* (Div. 2) CD, 9 EFG, 12

4C

STEP 5 – Select Back Box

Back Boxes - for use with DS441 and DS442 covers or with 1 gang and 2 gang DS/DSD Series covers

Dead End

EDS171

EDS271

EDS371

EDS172

EDS272

EDS372

Through Feed

EDSC171

EDSC271

EDSC371

EDSC172

EDSC272

EDSC372

Hub Size

1 /

2

3 /

4

1”

1 /

2

3 /

4

1”

Back Box Arrangement

Single gang back box

Single gang back box

Single gang back box

Double gang back box

Double gang back box

Double gang back box

  

Options:

Aluminum body

Exterior epoxy powder coat finish

Interior & exterior epoxy powder coat finish

Suffix

SA

S752

S753

Back Boxes – for use with DS443-SA cover or with 1 1

/

2

gang DS511 (3-operator) Series covers

Dead End

EFD1491 SA

EFD2491 SA

EFD3491 SA

  

Options

Through Feed

EFDC1491 SA

EFDC2491 SA

EFDC3491 SA

Exterior epoxy powder coat finish

Interior & exterior epoxy powder coat finish

  

Hub Size

1 /

2

3 /

4

1”

Back Box Arrangement

1 1 /

2

gang back box

1 1 /

2

gang back box

1 1 /

2

gang back box

Suffix

S752

S753 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright © 2014 Eaton’s Crouse-Hinds Business

4C EDS / EFS Series

Control Stations

FlexStation

Control

Station Components

Cl. I, Div. 1 & 2, Groups B (Div. 2 only) C, D

Cl. II, Div. 1 & 2, Groups E, F, G

Cl. III

Zone 1 & 2 Group IIB

NEMA 3R, 7B* (Div. 2) CD, 9 EFG, 12

Back Boxes – for use with DS441 and DS442 covers

Through Feed

EDSC378

Hub Size

1"

Common Cover Assemblies

Cat. #

DS455

DS476

➀ ➁

DS456 ➀ ➀

DS429§

DS454§

DS510 ➀ §

Description

With one pilot light

With one pilot light and transformer

With two pilot lights

With one pushbutton

With two pushbuttons

With one pushbutton and one pilot light

Back Box Arrangement

3 gang tandem

Add color symbol for each pilot light from table below.

Color Symbol Color

Red

Green

J1

J3

Amber

Clear

Add suffix below for transformer primary voltage:

Transformers – Voltages above 125

Nom. Volts 50–60Hz Transformer

220 / 110

440 / 110

550 / 110

Symbol

J6

J10

Primary Voltage Range

220–240

440–480

550–600

Color

Blue

Suffix

T2

T4

T5

Symbol

J11

§ If desired, markings on indicating plates may be added to catalog number. Select from the list of standard markings below:

START

STOP

ON

EMERGENCY

FORWARD

OFF

RUN

JOG

OPEN

CLOSE

RESET

TRIP

TEST

DOWN

IN

REVERSE

UP OUT

LIGHT ON

HAND

AUTOMATIC

RAISE

LOWER

518 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright © 2013 Eaton’s Crouse-Hinds Business