The DuplineSafe transmitter shall be used with other Carlo Gavazzi* devices. Please refer to the DuplineSafe Safety Input Module specification sheet (GS75102192-2) for all maintenance, installation, operating specifications, warnings and cautions AFU Addressability Control Switch Installation & Maintenance Information SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IF 1678 WARNING WARNING To prevent equipment damage, hammers or prying tools must not be allowed to damage the flat ground joint surfaces. Do not handle covers, transmitters and switch housings roughly, or place them on surfaces that might damage or scratch the flat ground joint surfaces. To avoid the risk of fire and electric shock, this product is to be installed by a qualified electrician only. APPLICATION The AFU Addressability Control Switch provides digital monitoring capability to the AFU Series Conveyor Control Safety Switches with slack condition. The AFU Addressability Control Switches are suitable for use in Class II, Groups E, F, G, and Class III hazardous (classified) locations as defined by the National Electrical Code® (NEC) and Canadian Electrical Code® (CEC). WARNING Attach wiring to transmitter following your system wiring pattern in compliance with the National Electrical Code plus any other applicable code. See Figure 3 for the wiring diagram. Figure 2 – DuplineSafe Transmitter To prevent electrical shock, be sure all power is turned off before and during installation and maintenance. SINGLE ENDED SWITCH INSTALLATION Refer to IF 958 - AFU/AFUX Series, Model M7 Conveyor Control Safety Switches with Slack Condition, for all maintenance, installation, operating specifications, warnings and cautions while using the AFU Addressability Control Switch. CONTACTS SHOWN IN THE TRIPPED STATE CONTACTS SHOWN IN THE TRIPPED STATE DOUBLE ENDED SWITCH See Figure 1 for the overall assembly of the AFU Addressability Control Switch, and Figure 2 for the addressability switch assembly. 1 1 1 2 2 2 3 3 3 4 4 4 5 5 6 6 7 7 8 8 5 6 7 INPUT 1 INPUT 2 INPUT 1 INPUT 2 +D 3 -D 4 Rx 5 Tx 6 DUPLINESAFE TRANSMITTER GS75102192-2 WHITE PINK 1 +D 3 2 BROWN 3 GREY 4 GREEN 5 YELLOW 6 -D 4 Rx 5 Tx 6 DUPLINE BUS OUT 1 PINK 2 BROWN 3 GREY 4 GREEN 5 YELLOW 6 DUPLINESAFE TRANSMITTER GS75102192-2 7 8 WHITE 8 DUPLINE BUS TO NEXT DEVICE +D -D 7 8 DUPLINE BUS IN Figure 3 – AFU Addressability Control Switch – Wiring Diagram *Note: Dupline is a registered trademark of the CARLO GAVAZZI Group. Perform visual, electrical and mechanical inspections on a regular basis. The environment and frequency of use should determine this. However, it is recommended that checks be made at least once a year. We recommend an Electrical Preventive Maintenance Program as described in the National Fire Protection Association Bulletin NFPA 70B: Recommended Practice for Electrical Equipment Maintenance (www.nfpa.org). Figure 1 – AFU Addressability Control Switch – Internal View All statements, technical information and recommendations contained herein are based on information and tests we believe to be reliable. The accuracy or completeness thereof are not guaranteed. In accordance with Crouse-Hinds “Terms and Conditions of Sale,” and since conditions of use are outside our control, the purchaser should determine the suitability of the product for his intended use and assumes all risk and liability whatsoever in connection therewith. IF 1678 • 06/15 Copyright © 2015 Eaton’s Crouse-Hinds Business Page 1 Eaton’s Crouse-Hinds Business 1201 Wolf Street, Syracuse, NY 13208 Copyright © 2015 IF 1678 Revision 2 Revised 06/15 Supercedes 10/13