NEW Solutions for Underground System Growth Cooper’s Single-Phase Pad-mounted Voltage Regulator Improved Power Quality ■ More Economical ■ Improved System Reliability ■ Increased Safety ■ Better Aesthetics ■ Lower Maintenance ■ URD Voltage Regulation with Fewer Problems Now you can add a new dimension to underground system planning and design. Cooper Power Systems’ pad-mounted voltage regulators give you new freedom in improving safety, reliability and power quality in existing and new underground systems. The pad-mounted voltage regulator helps reduce installation costs, and preserves a more aesthetically pleasing environment. Substation designers now have a full complement of product to install a complete, modular pad-mounted substation. Safety and reliability are enhanced, construction costs are reduced, land requirements are smaller, and the physical profile presented to the public is smaller and more attractive. Traditional methods of applying voltage regulation to 200 and 600 ampere URD systems all contain inherent drawbacks. Riser pole installation of regulators requires that a pole location be selected and approved, often a difficult process in congested or residential areas very sensitive to appearances. Exposing the cable to the added risk of lightning surge damage is another drawback, one that could prove to be very expensive in cable and equipment replacement costs. A traditionally designed substation, with the lengthy processes of gaining rights of way, permitting, and expensive construction, proves to be a time-consuming and costly alternative. In contrast, a deadfront, pad-mounted substation with voltage regulation can be designed so that it is easier to site, easier to install and maintain, while also being safer, more reliable and aesthetically pleasing. Three-Phase Transformer Ease of Operation Kyle® Vacuum Fault Interrupter Switchgear Single-Phase Pad-mounted Voltage Regulator Cooper’s single-phase padmounted voltage regulator has all the functionality of the traditional round tank regulators, with the convenience of pad mounting. The control box is mounted on the door of the operational side of the cabinet for easy access. As the operator uses the control, the gauges and the position indicator are in clear view. The junction box has a side door for the operator to access the terminal block for the connections from the oil tank to the control cable. The control is connected from the control box to the junction box with a quickdisconnect control cable, for easy removal. The current transformer is automatically shorted when the cable is removed. Single-Phase Shrubline® Transformer Product Scope Volts Amperes kVA Bushing BIL 7620 50, 75, 100, 150, 200 38, 57, 76, 114, 152 200 A well & 15 kV 200 A insert 95 7620 328, 438, 548 250, 333, 416 600 A integral bushing 95 14400 50, 100, 200 72, 144, 288 200 A well & 25 kV 200A insert 125 14400 300, 347, 400, 463 432, 500, 576, 667 600A integral bushing 125 Average winding rise: 65°C Short circuit withstand: twenty-five times rated current for 2 seconds Note: The 125 kV BIL rating is only limited by the bushing, all internal connections are designed and constructed to 150 kV BIL. The 7620 volt units rated 200 amperes or less are available with optional 25 kV class inserts. Voltage Ratings Voltage Available Tap Voltage 7620 8000, 7970, 7620, 7200, 6930, 4800, 4160, 2400 14400 14400, 13800, 13200, 12000, 7970, 7620, 7200, 6930 Note: Each unit is capable of operating at different excitation voltages. “Other system voltages, such as 4800 or 2400, are satisfied through the use of the 7620 volt rating and the potential transformer.” Substation Distribution Feeders A B C Three-Phase Transformer Single-Phase Pad-mounted Voltage Regulator Pad-mounted Switchgear Single-Phase Pad-mounted Voltage Regulator Single-Phase Pad-mounted Transformer Add-Amp The pad-mounted voltage regulator allows increased load carrying capacity at reduced ranges of regulation. The limitation is the bushing interface (marked with the *). Volts 7620 7620 7620 7620 7620 7620 7620 7620 14400 14400 14400 14400 14400 14400 14400 Amperes 50 75 100 150 200 328 438 548 50 100 200 300 347 400 463 10% 8.75% 7.50% 6.25% 5% 50 75 100 150 200 328 438 548 50 100 200 300 347 400 463 55 83 110 165 200* 361 482 600* 55 110 200* 330 382 440 509 60 90 120 180 200* 394 526 600* 60 120 200* 360 416 480 556 68 101 135 200* 200* 443 591 600* 68 135 200* 405 468 540 600* 80 120 160 200* 200* 525 600* 600* 80 160 200* 480 555 600* 600* Bypass Switch Module As with round tank regulators, bypassing a pad-mounted voltage regulator is an option in system operation. Installing or removing the pad-mounted voltage regulator from the circuit is accomplished with a stand-alone bypass switch module. This switch module fits inside the secure pad-mounted regulator cabinet during normal operation. When the regulator needs to be removed for normal servicing, the bypass module provides hot stick operable sectionalizing switches to disconnect the regulator from the system without causing interruption to the downstream load. Bypass Switch Ratings Voltage Current Bushings 7620 200 200 A wells and 15 kV inserts 7620 400 600 A integral bushings 7620 600 600 A integral bushings 14400 200 200 A wells and 25 kV inserts 14400 400 600 A integral bushings 14400 600 600 A integral bushings Standard Features The pad-mounted voltage regulator is delivered fully-equipped, ready for your application: Full metal barrier separating the two compartments Two parking stands Three bushing wells & inserts or 600 A terminations • Standard pad-mounted green paint • Ground pads • Bolted oil tank cover • Nameplates (2) • Deep (31") removable cabinet • Automatic pressure relief device • Lifting lugs • Under-oil bypass (3 kV) arrester • Provisions for pressure/vacuum gauge & thermometer 1" filter press connection and fill plug Control box with control Magnetic oil level and oil sight gauges Junction box and position indicator Optional bypass switch module with sectionalizing switches Optional Accessories 1" drain valve with sampler Optional external tap changer for PT taps Readily available accessories are shown below. Other accessories are available, please consult your Cooper Power Systems Sales Engineer. Bypass switch module Internal differential PT Alternate top coat color Deeper or shallower cabinet External tap changer for PT taps No barrier Dial type liquid level gauge Pressure/vacuum gauge Thermometer Under-oil shunt arresters (10 or 18 kV) Control heater assembly Scope Pad-mounted Step-Type Voltage Regulator Specification This specification covers outdoor, pad-mounted, single-phase, oil-immersed, step-type voltage regulators that provide 10% regulation in thirty-two (32) steps of approximately 5/8% each. Ratings The ratings and terminations shall be according to the following table: Voltage Current kVA Bushings BIL 7620 7620 14400 14400 50, 75, 100, 150, 200 328, 438, 548 50, 100, 200 300, 347, 400, 463 38, 57, 76, 114, 152 250, 333, 416 72, 144, 288 432, 500, 576, 667 200 600 200 600 95 95 125 125 A A A A wells and 15 kV class inserts integral bushings wells and 25 kV class inserts integral bushings The regulator shall be rated for an average winding rise of 65°C rise over a 30°C ambient. The regulator shall be capable of a short circuit withstand of twenty-five times rated current for two seconds. Note: The 125 kV BIL rating is limited by the bushing, all internal connections are designed and constructed to 150 kV BIL. Each unit will be capable of operating at different excitation voltages, with settings below: Voltage Available tap voltage 7620 8000, 7970, 7620, 7200, 6930, 4800, 4160, 2400 14400 Construction 14400, 13800, 13200, 12000, 7970, 7620, 7200, 6930 Three bushings shall be provided. The source-load bushing shall be externally grounded. Regulator Control The control panel shall be microprocessor based, have a temperature range of -40°C to +85°C with the following features: All regulators shall be provided with a 3.0 kV under-oil, metal oxide varistor (MOV) bypass arrester connected across the series winding. ■ Digital metering package of Class 1 accuracy with The tank and the cabinet shall be Munsell 7GY3.29/1.5 and meet the coating and security requirements of ANSI C57.12.28. ■ ■ ■ ■ The control enclosure shall be mounted on the right-hand compartment door and connected to the junction box with a quick-disconnect cable that automatically shorts the current transformer when the cable is disconnected. The operational (right-hand side) compartment shall be fully separated by a metal barrier from the system voltage (left-hand side) compartment to ensure operational safety conditions. Located in the operational compartment shall be: ■ An oil sight gauge which indicates oil color ■ A magnetic oil level gauge to indicate the oil level at 25°C ambient ■ A 1" drain valve with sampling device ■ A 1" upper filter press connection ■ A tap position indicator mounted inside the cabinet to instantaneous and time/date stamped demand values Voltage limiting capability Voltage reduction capability Reverse power flow capability Tap position tracking The following accessories shall be provided when checked. A bypass switch module which would mount inside the secure cabinet and allow the regulator to be removed from service without interrupting the continuity of the system. A (source-to-load) differential PT to provide complete operation and metering under reverse power flow conditions. A thermostatically-controlled heater assembly to reduce moisture in areas of high humidity. The heater assembly shall include an ON-OFF switch. In the ON position, a thermostat in the heater assembly shall activate the heater at approximately 30°C (85°F) and turn it off at approximately 40°C (100°F). minimize the incidence of damage ■ Two anodized aluminum laser-etched nameplates, one mounted on the control enclosure and the other mounted on the regulator tank. The nameplates shall have bar coding, in accordance with ANSI C57.12.33 Bulletin Number 97046 © 1997 Cooper Power Systems, Inc. Cooper Power Systems 2300 Badger Drive Waukesha, WI 53188-5951 Fax: 414-896-2350 www.cooperpower.com