Room Controller How to Specify a QuicKit

advertisement
Room Controller
How to Specify a QuicKit
The Room Controller QuicKit is shipped complete with all smart devices in a single box, including no programming required technology,
making installation simple and fast.
•
Complete all-in-one package solution for room based controls
•
Simplify room-based controls, specification and delivery
•
Ensures compliance with the latest national and state energy codes
•
UL924
Guarantees
UL924 design integrity with controls installation
UL924
Integrated Capabilities
UL924
UL924
UL924
Occupancy/Vacancy
Sensing
Daylighting
Control
Manual
Control
Receptacle
Control
UL924
Emergency
Integration
Demand
Response
Sample Room Controller Office Layout
How to specify a QuicKit
1.
Select your room type (defines Room Controller)
2.
Choose up to four (4) Wallstations
3.
Select the required Occupancy Sensor
4.
Choose Daylight Sensor options
5.
Choose Plug Load or BMS/Egress option
6.
Select Wallstation color
OCC-RJ45
(BMS output/Egress Control)
OCC-RJ45
(Connection to any Greengate sensor)
RC3DE
(3 Relay + 3 Dimmer
+ 1 Emergency Relay)
Half Lights
Full Lights
Raise
Lower
All Off
RC-5TSB-OS2-*
(Pre-engraved Wallstation)
OAWC-DT-120W
(Wall Corner Occupancy Sensor)
RC3DE
Emergency Lighting
Selecting your room type
•
RC3 = 3 relay switching
•
RC3D = 3 relay switching + 3 dimmers
•
RC3D2 = 3 relay switching + 2 dimmers
•
RC3DE = 3 relay switching + 3 dimmers + 1 emergency
DSRC-FMOIR
(Multi-zone Daylight Sensor)
Normal Lighting
(Load 1)
Normal Lighting
(Load 2)
SPRC-R-20-120
(20A Receptacle Control)
Line Voltage
to J-Box
Ordering
RCQK
-
OS3E
-
OS2
-
W1
-
-
P
-
W
Room Controller
Daylight
Station Color
QuicKit
D1 - Multi-zone Daylight Sensor
DH - Multi-zone Daylight Sensor w/
Handheld Remote
Options
W - White
G - Gray
V - Ivory
B - Black
Office Stations (Choose up to 4)
Types of Space
and Control
OS - Office Switching (RC3)
OS2 - Office 2 Zone Dimming (RC3D2)
OS3 - Office 3 Zone Dimming (RC3D)
OS3E - Office 3 Zone Dimming and
and Emergency Relay (RC3DE)
Page 1
D1
OS1 - Half Lights, Full Lights, All Off
(3 Large Buttons)
OS2 - Half Lights, Full Lights, Raise, Lower, All Off †
(5 Small Buttons)
OS3 - Half Lights, Full Lights, Under Cabinet, Raise, Lower, All Off †
(6 Small Buttons)
OS4 - All On, All Off (2 Large Buttons)
CR1 - General, Meeting, Whiteboard, Presentation, Raise, Lower, All Off
(6 Small Buttons - Scenes)
SS1 - Slider Station ††
www.coopercontrol.com
Occupancy Sensor
C1 - Ceiling DT 2000 sq. ft.
C2 - Ceiling PIR 1500 sq. ft.
C3 - Ceiling DT 1000 sq. ft.
W1 - Wall Corner DT
W2 - Wall Corner PIR
†
W3 - Hallway PIR
†† P - Plug Load
B - BMS/Egress
These dimming wallstations can only be used with dimming Room Controllers (RC3D, RC3D2, RC3DE)
Slider stations can not be used if a wallstation with Raise/Lower buttons are used
Room Controller
How to Specify a QuicKit
The first lighting control room based system that guarantees design simplification, ensures code compliance, provides single box no
programming required installation and is the most cost effective.
•
Reduce installation and setup time with smart devices that perform immediately without programming
•
Ensure compliance to the strictest energy codes without any interfaces or auxiliary devices
•
Pre-packaged systems guarantees design integrity 100% of the time
Sample Recessed Fixture Classroom Layout
Sample Suspended Fixture Classroom Layout
Load 3
Load 3
RC-6TSB-TS2-*
(Pre-engraved Wallstation)
RC-6TSB-TS2-*
(Pre-engraved
Wallstation)
Raise
RC3DE
Lower
Load 2
Load 2
Load 2
Dimmer 1
Dimmer 2
Dimmer 3
Normal Power
Connection
General On
AV Mode
Whiteboard
Quiet Time
Raise
Lower
RC3DE
Normal Power
Connection
RC3D
(3 Relay +
3 Dimmer)
Load 1
Load 2
Load 1
Quiet Time
Load 1
Load 2
Load 1
AV Mode
Whiteboard
Load 1
Load 2
Load 1
General On
RC3D
(3 Relay +
3 Dimmer)
General On
General On
Off
Load 1
Load 1
Dimmer 2
Dimmer 3
OAC-DT-2000
(Ceiling Dual
Tech, 2000 sq. ft.)
Load 1
Dimmer 3
Daylighting Zone 3
Dimmer 2
Load 1
Dimmer 3
Daylighting Zone 2
Daylighting Zone 1
Dimmer 2
Dimmer 3
Dimmer 3
Load 1
Dimmer 2
Dimmer 1
Dimmer 2
Load 1
Daylighting Zone 3
Daylighting Zone 2
Load 1
Dimmer 1
Daylighting Zone 1
Load 1
Dimmer 1
OCC-RJ45
(Connection to any
Greengate Sensor)
OCC-RJ45
(Connection to any
Greengate Sensor)
Dimmer 1
DSRC-FMOIR
(Multi-zone
Daylight Sensor)
DSRC-FMOIR
(Multi-zone
Daylight Sensor)
Load 1
Dimmer 1
RC-2TLB-ES1-*
(Pre-engraved
Wallstation)
Off
RC-2TLB-ES1-*
(Pre-engraved
Wallstation)
OAWC-DT-120W
(Wall Corner
Dual Tech)
Ordering
RCQK
-
CR3E
-
ES1
Room Controller
QuicKit
Types of Space
and Control
CR - Classroom Switching (RC3)
CR2 - Classroom 2 Zone Dimming (RC3D2)
CR3 - Classroom 3 Zone Dimming (RC3D)
CR3E - Classroom 3 Zone Dimming and
Emergency (RC3DE)
Entry Station (Choose 1)
ES1 - Entry, All Off (2 Large Buttons)
TS5 - Entry, General, Whiteboard, All Off
(4 Small Buttons)
Page 2
-
TS1
-
C1
-
D1
P
-
W
Station Color
Teacher Station (Choose up to 3)
Occupancy Sensor
ES1 - Entry, All Off
(2 Large Buttons)
TS1 - General, Whiteboard, Quiet Time, A/V Mode, Raise,
Lower † (6 Small Buttons)
TS2 - General, Whiteboard, Quiet Time, Raise, Lower, All Off †
(6 Small Buttons)
TS3 - General, Whiteboard, Quiet Time, A/V Mode, All Off †
(5 Small Buttons)
TS4 - General, Whiteboard, A/V Mode, Raise, Lower, All Off †
(6 Small Buttons)
TS5 - Entry, General, Whiteboard, All Off (4 Small Buttons)
TS6 - Entry, General, Whiteboard, Raise, Lower, All Off †
(6 Small Buttons)
TS7 - Row 1, Row 2, Row 3, Raise, Lower, All Off †
(6 Small Buttons)
TS8 - Uplights, Downlights, Accent, Raise, Lower, All Off †
(6 Small Buttons)
SS1 - Slider Station ††
C1 - Ceiling DT 2000 sq. ft.
C2 - Ceiling PIR 1500 sq. ft.
C3 - Ceiling DT 1000 sq. ft.
W1 - Wall Corner DT
W2 - Wall Corner PIR
W3 - Hallway PIR
www.coopercontrol.com
-
W - White
G - Gray
V - Ivory
B - Black
Options
P - Plug Load
B - BMS/Egress
Daylight
D1 - Multi-zone Daylight Sensor
DH - Multi-zone Daylight Sensor w/
Handheld Remote
†
†† These dimming wallstations can only be used with dimming Room Controllers (RC3D, RC3D2, RC3DE)
Slider stations can not be used if a wallstation with Raise/Lower buttons are used
Room Controller
How to Specify a QuicKit
Wallstation Sequence of Operations
The Room Controller wallstations are pre-labeled and preconfigured for their intended functon. They work as soon as they are connected to the Room Controller. Below
is a description of the functions of each wallstation button for office, classroom and conference room configurations. Each button is assigned to a specific program
number for how that button should operate. Program numbers may be used for several buttons that accomplish the same goal but may have different engraving.
Office Application Button Functionality
Function
Program
No.
Button Text
Control Type
9
Half Lights
Preset
Load 1 (yellow) ON, Load 2 (red) OFF
All Dimmers 50%
Solatube Open (RC3DE only)
10
Full Lights
Preset
Load 1 (yellow) ON, Load 2 (red) ON
All Dimmers 100%
11
Undercabinet
Toggle
Load 3 (purple) ON and OFF
(Unless a target level is indicated, the dimmer output
will default to daylight sensor control)
6
Raise
Raise
Raise All Dimmers
7
Lower
Lower
Lower All Dimmers*
16
All On
Preset
Load 1 (yellow) ON, Load 2 (red) ON, Load 3 (purple) ON
All Dimmers 100%
8
All Off
Preset
Load 1 (yellow) OFF, Load 2 (red) OFF, Load 3 (purple) OFF
Solatube Closed (RC3DE only)
Slider
Raise and Lower All Dimmers
Slider
Conference Room Application Button Functionality
Button Text
Control Type
12
General
Preset
Load 1 (yellow) ON, Load 2 (red) ON, Load 3 (purple) ON
Dimmer 1: 100%, Dimmer 2 80%, Dimmer 3 80%
Solatube Open (RC3DE only)
13
Meeting
Preset
Load 1 (yellow) ON, Load 2 (red) ON, Load 3 (purple) ON
Dimmer 1: 80%, Dimmer 2 20%, Dimmer 3 100%
Solatube Open (RC3DE only)
14
Whiteboard
Preset
Load 1 (yellow) ON, Load 2 (red) ON, Load 3 (purple) ON
Dimmer 1: 50%, Dimmer 2: 100%, Dimmer 3: 50%
Solatube Closed (RC3DE only)
15
Presentation
Preset
Load 1 (yellow) ON, Load 2 (red) ON, Load 3 (purple) ON
Dimmer 1: 30%, Dimmer 2: 0%, Dimmer 3: 25%
Solatube Closed (RC3DE only)
(Unless a target level is indicated, the dimmer output
will default to daylight sensor control)
6
Raise
Raise
Raise All Dimmers*
7
Lower
Lower
Lower All Dimmers*
16
All On
Preset
Load 1 (yellow) ON, Load 2 (red) ON, Load 3 (purple) ON
All Dimmers 100%
8
All Off
Preset
Load 1 (yellow) OFF, Load 2 (red) OFF, Load 3 (purple) OFF
Solatube Closed (RC3DE only)
Slider
Raise and Lower All Dimmers
Slider
Page 3
Function
Program
No.
www.coopercontrol.com
Room Controller
How to Specify a QuicKit
Classroom Application Button Functionality
Function
Program
No.
Button Text
Control Type
1
Entry
Row 1
Uplights
Toggle
Load 1 (yellow) ON and OFF
Solatube Open (RC3DE only)
2
General
Row 2
Downlights
Toggle
Load 2 (red) ON and OFF
3
Whiteboard
Row 3
Accent
Toggle
Load 3 (purple) ON and OFF
4
A/V Mode
Toggle
Toggles between A/V Mode and Normal Mode. In A/V Mode
relays will stay in their previous configuration. Dimmers will be
reduced to maintain light levels at 20%
5
Quiet Time
Toggle
Disables occupancy sensors and wallstation timers for 60
minutes. Toggle allows for re-enabling of Normal Mode prior
to the time expiring.
(Unless a target level is indicated, the dimmer output
will default to daylight sensor control)
6
Raise
Raise
Raise All Dimmers*
7
Lower
Lower
Lower All Dimmers*
8
All Off
Slider
Load 1 (yellow) OFF, Load 2 (red) OFF, Load 3 (purple) OFF
Solatube Close (RC3DE only)
Slider
Raise and Lower All Dimmers
Automatic Integrated Capabilities
Occupancy Sensor Mode
Vacancy Sensor Mode
Load 1
Auto On/Auto Off
Manual On/Auto Off
Load 2
Manual Auto On/Auto Off
Manual On/Auto Off
Load 3
Manual Auto On/Auto Off
Manual On/Auto Off
Receptacle
Control
On with Occupancy
Off with Vacancy
On with Occupancy
Off with Vacancy
Solatube
Open Load 1 On
Close Vacancy, All Off, A/V Mode
Open Load 1 On
Close Vacancy, All Off, A/V Mode
BMS/Egress
Output
Close on Occupancy
Open on Vacancy
Close on Occupancy
Open on Vacancy
Refer to Room Controller website for more information on other integral no programming required benefits like Demand
Response, Solatube Control, Egress Control, BMS Output, Alert Mode, Emergency Lighting Control, and Slider Stations.
Page 4
ACC130059
www.coopercontrol.com
Download