5 x 20mm Fuses GDA Series, Fast-Acting, Ceramic Tube

advertisement

5 x 20mm Fuses

GDA Series, Fast-Acting, Ceramic Tube

Description

• Fast-acting, high breaking capacity

• 5 x 20mm physical size

• Ceramic tube, nickel-plated brass endcap construction

• Silver-plated endcap construction (50mA-400mA)

• Optional axial leads are 0.032" x 1.5" copper tinned

• Designed to IEC 60127-2

Electrical Characteristics

In

1.5 In 2.1 In min max

2.75 In min max min

4 In max

10 In max

50mA-3.15A 60 min 30 min 10 ms 2 sec 3 ms 300 ms 20 ms

4A-10A 60 min 30 min 10 ms 3 sec 3 ms 300 ms 20 ms

Agency Information

• UL Recognized Card: Guide JDYX2, File E19180

• CSA Component Acceptance: File 53787

• Semko Approval: File 413779, File 512433

• IMQ Approval: File EB405

• CCC: File 2005010207155691

Ordering

Specify product code

• Insert packaging code prefix before part number. E.g.

BK/GDA-250mA

Specify option code if desired

• For axial leads, insert “V” between catalog series and amp rating. E.g. BK/GDA-V-250mA

Dimensions - mm

Drawing Not to Scale

• With TR2 packaging code, lead wire length is 19.05mm

Specifications

Voltage Interrupting Rating (amps) Typical DC Typical Typical

Part Number Rating at Rated Voltage (50Hz) Cold Resistance Melting I

Vac Vac (

Ω

)* (amps)

2 t Voltage

Drop (mV)‡

GDA-50mA 250 1500 157.5

0.0017

9000

GDA-63mA 250 1500 39.0

0.0005

3300

GDA-80mA

GDA-100mA

GDA-125mA

GDA-160mA

GDA-200mA

GDA-250mA

GDA-315mA

GDA-400mA

GDA-500mA

GDA-630mA

GDA-800mA

GDA-1A

GDA-1.25A

GDA-1.6A

GDA-2A

GDA-2.5A

GDA-3.15A

GDA-4A

GDA-5A

GDA-6.3A

250

250

250

250

250

250

250

250

250

250

250

250

250

250

250

250

250

250

250

250

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

0.460

0.340

0.245

0.231

0.176

0.113

0.073

0.053

27.9

20.0

12.3

8.5

6.0

4.4

3.3

2.2

0.037

0.027

0.019

0.014

0.0011

0.0018

0.0037

0.008

0.020

0.027

0.010

0.018

0.038

0.064

0.097

0.146*

0.313*

0.748*

2.0

3.9

8.1

14

25

48

1050

1200

490

330

297

239

205

190

2600

2300

1900

1600

1350

1300

1400

1200

160

160

155

150

‡ Typical Voltage Drop (Voltage drop was measured at 20ºC ambient temperature at rated current)

*I 2 t of 1A, 1.25A, 1.6A is measured at 10In DC.

**CSA Approvals on these ratings will not be marked on the fuse cap.

Agency Approvals

IMQ SEMKO UR CCC

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

CSA

X

X

X

X

X

X

X

X

X

X

X

X

X**

X**

X**

X**

X**

X

0209 BU-SB08725 Page 1 of 2 Data Sheet 2014

Time-Current Curve

Amp

Rating

Current In Amps

Option Code

V

Packaging Code

BK

BK1

TR2

Option Code

Description

Axial leads - copper tinned wire with nickel-plated brass endcaps

Description

Packaging Code

100 fuses packed into a cardboard carton

1,000 fuses packed into a poly bag

1,500 fuses packed into tape on a reel (19.05mm lead wire length)

The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.

Life Support Policy: Cooper Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user.

© 2 0 0 9 C o o p e r B u s s m a n n

S t . L o u i s , M O 6 3 1 7 8 w w w. c o o p e r b u s s m a n n . c o m

0209 BU-SB08725 Page 2 of 2 Data Sheet 2014

Download