High Performance T8 Solutions

advertisement
OpticaHP Series
2HP Series
Accord Series
Ovation Series
High Performance T8
Solutions
Introduction
Enhanced Illumination…. Lower Operating Costs
Working today to reduce energy costs does not mean that the quality of the lighting has to be sacrificed. Metalux has combined
the latest T8 lamp and ballast technology with the newest recessed architectural products that not only enhance the work
environment but will lower operating and maintenance costs.
The Accord , Ovation , OpticaHP and 2HP families provide exciting alternatives to traditional fluorescent recessed lighting products.
Each family balances the lighting in the vertical and horizontal zones to give the space a softer, more comfortable feel. The combination
of luminaire efficiency and a high performance T8 system allows the flexibility to meet a wide range of
light levels with a two lamp system while providing significant reduction in energy usage.
TM
TM
T8
Index
Product Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Product Comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Retrofit Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
OpticaHP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
2HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Ovation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Accord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Accord
TM
Distributing light throughout the space, the Accord eliminates uneven distribution and
makes the room feel comfortable and inviting. It’s smooth curved surfaces and matte
white finish provide a design that is attractive but subtle in application.
OpticaHP
Building on the Metalux Optica Series, the OpticaHP family combines a precision faceted blade design
with new high efficient T8 technology to produce optimal performance and aesthetic styling.
Ovation
TM
Carefully balanced design elements combine to provide an efficient and inviting high
performance alternative to traditional general lighting. The Ovation utilizes a matte
white indirect reflector and a perforated direct lamp shield to provide optimum
brightness control.
2HP
Precision formed white or semi-specular louver that creates a soft, even distribution while delivering high
efficiency. The 2HP luminaire is compatible with all of today’s popular ceiling systems and is available
with a number of options and accessories for increased application versatility.
1
Product Comparison
Maximizing Energy Savings
Combine HPT8 Step
Dimming Ballasts
with Cooper Control
products for optimal
energy savings.
High Performance T8 systems allow the flexibility to tune the light output and energy usage by
changing the luminaire ballast factor to adapt to needed light levels and energy requirements
within an application. Using fewer lamps will help reduce future maintenance and recycling costs.
HPT8 Lamp Advantages
HPT8 Ballast Advantages
• Higher Lumens
• Longer Life
• Higher CRI Rating
• No Issues with Temperature or Dimming
• Reduced Energy Consumption
• Flexible Light Output*
• Instant and Program Start Designs
HPT8 Lamping Advantages (4', T8 Lamps)
Parabolic Comparison (3 Lamp vs. 2 Lamp HPT8)
32 Watt
Standard
32 Watt
High Performance
25/28/30 Watt
Energy Saving
2750+
3100
2500+
20,000+
24,000+
24,000+
0
-20
60
CRI
>75
>80
>80
Emergency
Yes
Yes
Limited
Dimming
Yes
Yes
Limited
Initial Lumens
Lamp Life
Starting Temp. (°F)
Ballast
Ballast
Factor
Light
Levels
Energy
Savings
HB81L,
HR81L
.77 – .77
M
L
HB81,
HR81
.88
=
L
HB81N
1.0
=
L
HB81H,
HR81H
1.15 – 1.2
L
M
*Also available with Step Dimming Ballasts for additional light output control.
Standard Parabolic
OpticaHP Parabolic
(3) 32W T8 Lamps, 12 Fixtures
Electronic Ballast (.87 Ballast Factor)
83 Watts per Fixture
(2) 32W T8 Lamps, 12 Fixtures
Electronic Ballast (1.0 Ballast Factor)
62 Watts per Fixture
Based on:
Room Size: 50' x 30'
Ceiling Height: 10'
Work Plane: 2.5'
Reflectances: 80/50/20
36
34
IES*
16
.67
Watts/Sq.ft.
2
Horizontal
Vertical
Footcandles Footcandles
IES*
*IES recommends 30–35 footcandles in
open office environments.
19
0.50
Watts/Sq.ft.
Horizontal
Vertical
Footcandles Footcandles
Standard Troffer
Accord
(4) 32W T8 Lamps, 12 Fixtures
Electronic Ballast (.87 Ballast Factor)
122 Watts per Fixture
(2) 32W T8 Lamps, 12 Fixtures
Electronic Ballast (1.20 Ballast Factor)
77 Watts per Fixture
Based on:
Room Size: 50' x 30'
Ceiling Height: 10'
Work Plane: 2.5'
Reflectances: 80/50/20
50
IES*
Watts/Sq.ft.
41
23
IES*
*IES recommends 30–35 footcandles in
open office environments.
0.98
Horizontal
Vertical
Footcandles Footcandles
TM
24
0.62
Watts/Sq.ft.
Horizontal
Vertical
Footcandles Footcandles
3
Retrofit Kit
OpticaHP Retrofit Kit
The OpticaHP retrofit kit has been designed to balance performance and energy savings in an environmentally friendly solution.
The kit not only offers a visual improvement over traditional parabolics, there will be significant savings from lowered energy
consumption and reduced maintenance. The OpticaHP is readily available in unit packs and, in order to
optimize savings and further reduce waste, the kits are also available in bulk pack configurations
that are recommended for larger jobs.
Key Advantages of the OpticaHP Retrofit Kit:
• Lower Energy Costs: Save up to 40% Compared to Standard 3-Lamp Parabolics
• Improved Lighting: Even Delivery of Light that Eliminates Shadows
• Less Waste: Reusing Existing Housing results in Less Handling and a Lower Disposal Cost
• Pre-Wired Kits: Avoids Additional Time & Expense of Field Wiring
OpticaHP Retrofit Kit Installation
1. Install the Socket Track Flange.
4
2. Secure Ballast and Socket Tracks.
3. Attach Supply Wires to Quick Disconnect.
Lighting before OpticaHP
• Efficiency: 69.1%
• Input Watts: 86
• Lumens/Watt: .59.4
• Vertical Illumination: 1:2.5
• Lamp Life: 20,000 hours
• CRI (Color Rendering Index): >75
Lighting with OpticaHP
• Efficiency: 87.6%
• Input Watts: 53
• Lumens/Watt: 88.5
• Vertical Illumination: 1:1.9
• Lamp Life: 24,000+ hours
• CRI (Color Rendering Index): >80
Ordering Information
SAMPLE NUMBER: 2OPRK-232-UNV-HB81L-4
Width
2=2' Nominal
Number of Lamps
2=2 lamps
(Not Included)
Series
OPRK=Optica HP
Retrofit Kit
Wattage (Length)
17=17W T8 (24")
32=32W T8 (48")
28T8=28W T8 (48") (2)
Voltage (1)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277
Ballast Type (1)
HPT8 Ballast
HB8 L=T8 Electronic Instant Start. Low Ballast Factor >.71–.77
HB8 =T8 Electronic Instant Start. Ballast Factor .88
HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2
HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Start. Low Ballast Factor .71–.77
HR8 =T8 Electronic Program Start. Ballast Factor .88
HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2
(1)
Packaging
B=Bulk Pack, Palletized
(48" – 20 per Pallet)
(24" – 40 per Pallet)
U=Unit Pack
(For large jobs order
Bulk Pack for maximum
savings and reduced
packaging waste)
(2)
NOTES: Products also available in non-US voltages and frequencies for international markets. Standard ballast configurations also available. When utilizing 28W T8 lamps, HPT8 Ballast must be specified.
For complete product data, go to www.metalux-lighting.com. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
4. Insert Reflector and attach to Socket Tracks
(install lamps).
5. Position Louver Hinges into Existing Slots.
6. Secure Louver by engaging Spring Latches.
5
OpticaHP
OpticaHP 2' x 4' Photometrics
Candela
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
2OPG-232-UNV
Electronic Ballast
(2) F32T8 32W lamps
3100 lumens
Spacing criterion:
(II) 1.2 x mounting height,
(⊥) 1.4 x mounting height
Efficiency = 87.1%
Test Report:
2OPG-232FB26W.IES
LER = FP-84
Yearly Cost of 1000
lumens, 3000 hrs at .08
KWH = $2.86
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
104
95
87
79
72
66
61
57
53
49
46
97
85
75
66
59
52
47
43
39
36
33
93
82
72
64
56
51
46
42
38
35
32
89
79
69
61
55
49
44
40
37
34
32
87
74
62
52
44
38
33
29
26
23
21
104
91
80
70
62
55
50
45
41
37
35
104
87
74
63
54
47
42
37
33
30
28
104
84
69
57
48
42
36
32
28
25
23
101 101 101 101
93 89 86 83
84 78 73 68
77 69 62 57
70 61 54 48
65 54 47 41
60 49 41 36
55 44 37 32
51 40 33 28
48 37 30 25
45 34 27 23
97
83
70
60
52
46
41
36
33
30
27
97
80
66
56
47
41
36
32
28
25
23
93
80
68
59
51
45
40
36
32
29
27
93
78
65
55
47
40
35
31
28
25
23
Zonal Lumen Summary
Ty p i c a l VC P Pe r c e n t a g e s
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Lumens
%Lamp
1463
2425
4397
5400
0
5400
23.6
39.1
70.9
87.1
0
87.1
%Fixture
27.1
44.9
81.4
100.0
0
100
Height Along
8.5’ 10.0’
60
66
59
60
55
56
63
64
58
58
Illuminance Estimator
89
77
66
57
50
44
39
35
32
29
26
89
75
64
54
46
40
35
31
28
25
23
Height Across
8.5’ 10.0’
60
63
59
61
57
58
63
64
59
59
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
45°
Across⊥
1825
1823
1797
1755
1688
1607
1508
1397
1273
1141
1001
1825
1834
1823
1795
1751
1690
1617
1529
1432
1327
1206
1825
1844
1848
1838
1816
1781
1737
1689
1624
1530
1405
857
711
562
407
263
155
73
0
1062
896
720
480
250
149
68
0
1260
1051
649
333
235
145
62
0
Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD)
Based on 100 ft. x 100 ft. Open Room
Ballast Factor
0.77
0.88
1.0
1.15
FC LPD FC LPD FC LPD FC LPD
8' x 10'
46 0.58 52 0.64 60 0.74 69 0.88
10' x 10'
38 0.48 43 0.53 49 0.62 57 0.73
10' x 12'
31 0.38 35 0.42 40 0.50 46 0.58
Choose the spacing and ballast factor to determine the average footcandle and
watts per square foot values. All calculations are based on the published IESNA
Zonal Cavity Method and associated algorithms. Results are calculated from
the content of the manufacturer’s photometric files.
Fixture
Spacing
2OPG-232FB26W
Ordering Information
SAMPLE NUMBER: 2OPG-232FB26W-UNV-HB81-U
Rating
Blank=
Standard
Number
of Lamps
2=2 Lamps
Width
2=2' Width
Wattage (Length)
28T8=28W T8 (48") (4)
32=32W T8 (48")
OP=Optica HP Series
Trim Type
G=Grid/Lay-in (Standard) (6)
F=Aluminum Flange Trim (7)
MZ=Modular Trim
Cross Blade
FB=Faceted Blade
Cell Configuration
26=2 Rows of 6, 12 Cell
Louver Finish
W=Matte White
Option – Aluminum Flange Trim (7)
Blank=SW (Single White)
Type
Color
‘S’ Single
‘N’ Natural
‘R’ In Row
‘W’ White
‘E’ End of Row
(1)
Voltage (2)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal Voltage
120-277 (3)
Options
Packaging
Ballast Type (2)
R=Internal Reflector
U=Unit Pack
HPT8 Ballast
PAL=Job Pack,
HB8 L=T8 Electronic Instant Start. Low Ballast Factor .71–.77
out of carton
HB8 =T8 Electronic Instant Start. Ballast Factor .88
PALC=Job Pack,
HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0
in carton
HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2
HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Start. Low Ballast Factor .71–.77
HR8 =T8 Electronic Program Start. Ballast Factor .88
HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2
Options
GL=Single Element Fuse
GM=Double Element Fuse
Flex=Flex Installed
(Reference Flex ordering information)
EL=Emergency Installed (5)
Lamps Installed (8)
Blank=No Lamps Installed
L8835=T8 Lamp, 28W and 32W, 3500K (4)
L8841=T8 Lamp, 28W and 32W, 4100K (4)
L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens
L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens
ACCESSORIES
EQ-CLIP-U=T-BAR Safety
Earthquake Clips(1)
(2)
NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Products also available in non-US voltages and frequencies for international markets. Standard ballast configurations
(3)
(4)
(5)
also available. Not available when specifying emergencies, voltage must be specific. When utilizing 28W T8 lamps, HPT8 Ballast must be specified. Fixtures equipped with “EL” option may require a 5-1/2" housing
(6)
(7)
(8)
depth. If installing in field, must use low profile battery pack.
Louver is recessd by 5/16" in Concealed T or Slot Grid. Specify row configuration, type in catalog number when ordering complete fixture. Other lamp
options available.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
6
OpticaHP 2' x 2' Photometrics
Coefficients of Utilization
rc
2OPG-217FB23MWUNV-EB81-U
Electronic Ballast
(2) F17T8 17W lamps
1450 lumens
Spacing criterion:
(II) 1.2 x mounting height,
(⊥) 1.4 x mounting height
Efficiency = 82.5%
Test Report:
OPG-217FB23MW.IES
LER = FP-65
Yearly Cost of 1000
lumens, 3000 hrs at .08
KWH = $3.69
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
98
90
82
75
69
63
58
54
50
47
44
98
87
76
67
59
53
48
43
39
36
33
98
83
70
60
52
46
40
36
32
29
27
98
80
66
55
47
40
35
31
28
25
22
20%
50%
30%
10%
70 50 30 10
50 30 10
50 30 10
50 30 10
0
96
88
80
73
67
62
57
53
49
46
43
92
81
71
63
56
50
45
41
38
35
32
88
78
69
61
54
49
44
40
37
34
31
84
75
66
59
52
47
43
39
36
33
30
82
70
59
50
43
37
32
29
25
23
21
96
85
74
65
58
52
47
42
39
36
33
96
82
69
59
51
45
40
36
32
29
27
96
79
65
55
46
40
35
31
27
25
22
92
79
67
58
50
44
39
35
32
29
26
92
76
64
54
46
40
35
31
27
25
22
88
76
65
56
49
43
38
34
31
28
26
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Angle
In Deg
45
55
65
75
85
Lumens
672
1108
1982
2392
0
2392
0%
%Lamp
23.2
38.2
68.3
82.5
0
82.5
%Fixture
28.1
46.3
82.9
100.0
0
100.0
88
74
62
53
45
39
34
30
27
24
22
Average
0-Deg
cd/sm
2361
2121
1775
1315
986
84
73
63
55
48
42
38
34
31
28
26
Average
45-Deg
cd/sm
2772
2657
2339
1303
986
84
72
61
52
44
39
34
30
27
24
22
Average
90-Deg
cd/sm
3249
3285
2010
1328
910
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
45°
Across⊥
862
854
835
809
774
731
682
626
565
505
438
368
298
227
159
103
61
26
0
862
857
844
827
802
771
734
691
643
593
531
461
381
299
183
102
60
26
0
862
860
857
847
835
817
798
772
740
695
634
570
462
257
142
104
61
24
0
Ordering Information
SAMPLE NUMBER: 2OPG-217FB23W-UNV-HB81-U
Rating
Blank=
Standard
Number
of Lamps
2=2 Lamps
Width
2=2' Width
Wattage (Length)
17=17W T8 (24")
U1-5/8=31W T8 (24")
OP=Optica HP Series
Trim Type
G=Grid/Lay-in (Standard) (6)
F=Aluminum Flange Trim (5)
MZ=Modular Trim
Cross Blade
FB=Faceted Blade
Cell Configuration
23=2 Rows of 3, 6 Cell
Louver Finish
W=Matte White
Option – Aluminum Flange Trim (5)
Blank=SW (Single White)
Type
Color
‘S’ Single
‘N’ Natural
‘R’ In Row
‘W’ White
‘E’ End of Row
(1)
Voltage (2)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal Voltage
120-277 (3)
Options
Packaging
Ballast Type (2)
R=Internal Reflector
U=Unit Pack
HPT8 Ballast
(Not
available
for
PAL=Job Pack,
HB8 L=T8 Electronic Instant Start.
U1-5/8 lamp)
out of carton
Low Ballast Factor .71–.77
PALC=Job Pack,
HB8 =T8 Electronic Instant Start. Ballast Factor .88
in carton
HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2
HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Start. Low Ballast Factor .71–.77
HR8 =T8 Electronic Program Start. Ballast Factor .88
HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2
Options
GL=Single Element Fuse
GM=Double Element Fuse
WTR=White Reveal
Flex=Flex Installed
(Reference Flex ordering information)
EL=Emergency Installed (4)
Lamps Installed (7)
L8835=T8 Lamp, 17W, 3500K
L8841=T8 Lamp, 17W, 4100K
ACCESSORIES
EQ-CLIP-U=T-BAR Safety
Earthquake Clips(1)
(2)
NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Products also available in non-US voltages and frequencies for international markets. Standard ballast configurations
(3)
(4)
also available. Not available when specifying emergencies, voltage must be specific. Fixtures equipped with “EL” option may require a 5-1/2" housing depth. If installing in field, must use low profile battery pack.
(5)
(6)
(7)
Specify row configuration, type in catalog number when ordering complete fixture. Louver is recessed by 5/16" in Concealed T or Slot Grid. Other lamp options available.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
7
2HP
2HP 2' x 4' Photometrics
Coefficients of Utilization
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
101
93
84
77
71
65
60
55
52
48
45
101
89
78
68
61
54
49
44
40
37
34
101
85
72
62
53
47
41
37
33
30
27
101
82
67
56
48
41
36
31
28
25
23
99
90
82
75
69
63
58
54
50
47
44
99
87
76
67
59
53
48
43
40
36
33
99
84
71
61
53
46
41
36
33
30
27
99
81
67
56
47
41
35
31
28
25
23
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
94
83
73
65
57
51
46
42
38
35
33
90
80
70
62
55
50
45
41
37
34
32
87
77
68
60
54
48
43
40
36
33
31
85
72
60
51
44
38
33
29
26
23
21
94
81
69
59
51
45
40
36
32
29
27
94
78
65
55
47
40
35
31
28
25
23
90
78
67
58
50
44
39
35
32
29
26
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
In Deg
45
55
65
75
85
Lumens
1323
2200
3975
4833
4833
%Lamp
23.3
38.6
69.7
84.8
84.8
%Fixture
27.5
45.5
82.3
100.0
100.0
90
76
64
54
46
40
35
31
28
25
22
Average
0-Deg
cd/sm
2331
2123
1782
1191
945
Illuminance Estimator
Choose the spacing and ballast factor to determine the average footcandle and
watts per square foot values. All calculations are based on the published IESNA
Zonal Cavity Method and associated algorithms. Results are calculated from
the content of the manufacturer’s photometric files.
87
75
65
56
49
43
38
35
31
28
26
Average
45-Deg
cd/sm
2792
2747
2430
1318
1059
87
74
62
53
45
39
35
31
27
25
22
Average
90-Deg
cd/sm
3312
3333
2266
1350
1172
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
Across⊥
45°
1674
1660
1625
1571
1502
1422
1331
1231
1120
1000
870
1674
1673
1665
1646
1603
1543
1462
1374
1288
1198
1090
1674
1680
1697
1694
1667
1619
1585
1552
1501
1421
1306
739
604
457
316
187
112
50
0
956
797
623
400
207
123
56
0
1160
967
581
301
212
135
62
0
Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD)
Based on 100 ft. x 100 ft. Open Room
2HP2GX-232W26P
Ballast Factor
0.77
0.88
1.0
1.15
FC LPD FC LPD FC LPD FC LPD
8' x 10'
45 0.58 51 0.64 58 0.74 67 0.88
10' x 10'
37 0.48 42 0.53 48 0.62 55 0.73
10' x 12'
30 0.38 34 0.42 39 0.50 45 0.58
Fixture
Spacing
2HP2-232W26P
Electronic Ballast
(2) F32T8/840 lamps
2850 lumens
Spacing criterion:
(II) 1.2 x mounting height,
(⊥) 1.4 x mounting height
Efficiency = 84.8%
Test Report:
2HP2-232W26P.IES
LER = FP-79
Yearly Cost of 1000
lumens, 3000 hrs at .08
KWH = $3.04
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Candela
Ordering Information
SAMPLE NUMBER: 2HP2GX-232W26P-UNV-HB81H-U
Rating
Blank=
Standard
NY=New York
City Rated
ATW-SW4=
Chicago
Rated
HR=Heat
Removal (1)
Width
2=2' Width
H=High Performance
P=Paralux Louver
2=2" Louver Depth
Trim Type
G=Grid/Lay-in (Standard)
G or T=Concealed T
G or T=Slot Grid (2)
F=Aluminum Flange Trim (5)
MZ=Modular Trim
AX=Air Supply Floating Louver
X=Blank Side/Floating Louver Non-Air Supply (Omit A)
AVX=Air Supply Floating Louver
with Directional Air Vane (Add V)
8
Number
of Lamps
2 or 3 lamps
Wattage (Length)
28T8=28W T8 (48") (5)
32=32W T8 (48")
Louver Color
W=White (Standard)
S=Silver
Cell Configuration
26=2 Rows of 6, 12 Cell
(2' x 4')
36=3 Rows of 6, 18 Cell
(2' x 4')
Louver Finish
P=Painted White (Standard)
I=Semi-Specular/Haze (Low
Iridescent) (Silver Only)
Option – Aluminum Flange Trim (7)
Blank=SW (Single White)
Type
Color
‘S’ Single
‘N’ Natural
‘R’ In Row
‘W’ White
‘E’ End of Row
Voltage (3)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277 (4)
Options
GL=Single Element
Fuse
GM=Double
Element Fuse
WTR=White Reveal
Flex=Flex Installed
(Reference Flex
ordering information)
EL=Emergency
Installed (6)
Lamps Installed (8)
Blank=No Lamps
Installed
L8835=T8 Lamp,
28W and 32W,
3500K (5)
L8841=T8 Lamp,
28W and 32W,
4100K (5)
L8835HL=T8 Lamp,
32W, 3500K, 3100
Lumens
L8841HL=T8 Lamp,
32W, 4100K, 3100
Lumens
Ballast Type (3)
HPT8 Ballast
HB8 L=T8 Electronic Instant Start.
Low Ballast Factor .71–.77
HB8 =T8 Electronic Instant Start.
Ballast Factor .88
HB8 N=T8 Electronic Instant Start.
Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start.
High Ballast Factor 1.15-1.2
HR8 DIM=T8 Electronic Program
Start Step Dimming. Ballast Factor
.88
HR8 L=T8 Electronic Program
Start. Low Ballast Factor .71–.77
HR8 =T8 Electronic Program Start.
Ballast Factor .88
HR8 H=T8 Electronic Program
Start. High Ballast Factor 1.15-1.2
(1)
Options
Packaging
RIF1=Radio
U=Unit Pack
Interference
PAL=Job Pack,
Suppressor
out of carton
20GA/REP=20 Gauge
PALC=Job Pack,
Riveted Endplates.
in carton
For use in New York City.
RLS=Rotor-Lock Socket
(T8 Lamps Only)
(Additional options available)
ACCESSORIES
EQ-CLIP-U=T-BAR Safety
Earthquake Clips(2)
(2)
NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid
(3)
Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Products also
available in non-US voltages and frequencies for international markets. Standard ballast
(4)
configurations also available. Not available when specifying emergencies, voltage must
(5)
(6)
be specific. When utilizing 28W T8 lamps, HPT8 Ballast must be specified. Fixtures
equipped with “EL” option may require a 5-1/2" housing depth. If installing in field, must use
(7)
low profile battery pack. Specify row configuration, type in catalog number when ordering
(8)
complete fixture. Other lamp options available.
For complete product data, reference the Fluorescent Specification binder. Specifications &
dimensions subject to change without notice. Consult your Cooper Lighting Representative for
availability and ordering information.
2HP 2' x 2' Photometrics
Coefficients of Utilization
2HP2-217W23P
Electronic Ballast
(2) F17T8/TL835 lamps
1450 lumens
Spacing criterion:
(II) 1.2 x mounting height,
(⊥) 1.3 x mounting height
Efficiency = 81.9%
Test Report:
2HP2-217W23P.IES
LER = FP67
Yearly Cost of 1000
lumens, 3000 hrs at .08
KWH = $3.58
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
97
90
82
75
68
63
58
54
50
47
44
97
86
75
66
59
53
47
43
39
36
33
97
83
70
60
52
46
40
36
32
29
27
97
80
65
55
47
40
35
31
28
25
23
95
87
80
73
67
61
57
53
49
46
43
95
84
74
65
58
52
47
42
39
36
33
95
81
69
59
51
45
40
36
32
29
27
95
78
65
54
46
40
35
31
28
25
22
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
91
81
71
63
56
50
45
41
38
35
32
87
77
68
60
54
48
44
40
37
34
31
84
74
66
58
52
47
43
39
36
33
31
82
70
59
50
43
37
32
29
25
23
21
91
78
67
58
50
44
39
35
32
29
26
91
76
63
53
46
40
35
31
27
25
22
87
75
65
56
49
43
38
34
31
28
26
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Angle
In Deg
45
55
65
75
85
Lumens
683
1112
1963
2374
0
2374
%Lamp
23.6
38.4
67.7
81.9
0
81.9
%Fixture
28.8
46.9
82.7
100.0
0
100.0
87
74
62
52
45
39
34
30
27
25
22
Average
0-Deg
cd/sm
2541
2296
1891
1245
1141
84
73
63
55
48
42
38
34
31
28
26
Average
45-Deg
cd/sm
2750
2655
2394
1312
1180
84
71
60
51
44
39
34
30
27
24
22
Average
90-Deg
cd/sm
3220
3288
2337
1232
1141
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
45°
Across⊥
883
879
861
834
798
755
706
650
589
524
455
883
880
871
848
819
786
736
676
619
567
510
883
885
880
864
844
803
763
736
705
664
608
384
310
233
158
94
59
29
0
444
370
295
195
99
61
30
0
550
467
288
130
93
63
29
0
Ordering Information
SAMPLE NUMBER: 2HP2GX-217W23P-UNV-HB81H-U
Rating
Blank=
Standard
NY=New York
City Rated
ATW-SW4=
Chicago
Rated
HR=Heat
Removal (1)
Width
2=2' Width
H=High Performance
P=Paralux Louver
2=2" Louver Depth
Trim Type
G=Grid/Lay-in (Standard)
G or T=Concealed T
G or T=Slot Grid (2)
F=Aluminum Flange Trim (5)
MZ=Modular Trim
AX=Air Supply Floating Louver
X=Blank Side/Floating Louver Non-Air Supply (Omit A)
AVX=Air Supply Floating Louver
with Directional Air Vane (Add V)
Number
of Lamps
2 lamps
Wattage (Length)
17=17W T8 (24")
U1-5/8=31W T8 (24")
Louver Color
W=White (Standard)
S=Silver
Cell Configuration
23=2 Rows of 3, 6 Cell
(2' x 2')
33=3 Rows of 3, 9 Cell
(2' x 2')
Louver Finish
P=Painted White (Standard)
I=Semi-Specular/Haze (Low
Iridescent) (Silver Only)
Option – Aluminum Flange Trim (5)
Blank=SW (Single White)
Type
Color
‘S’ Single
‘N’ Natural
‘R’ In Row
‘W’ White
‘E’ End of Row
Voltage (3)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277 (4)
Options
GL=Single Element
Fuse
GM=Double
Element Fuse
WTR=White Reveal
Flex=Flex Installed
(Reference Flex
ordering information)
EL=Emergency
Installed (6)
Lamps Installed (7)
Blank=No Lamps
Installed
L8835=T8 Lamp,
17W, 3500K
L8841=T8 Lamp,
17W, 4100K
Options
Packaging
Ballast Type (3)
RIF1=Radio
U=Unit Pack
HPT8 Ballast
Interference
PAL=Job Pack,
HB8 L=T8 Electronic Instant Start.
Suppressor
out of carton
Low Ballast Factor .71–.77
20GA/REP=20
Gauge
PALC=Job Pack,
HB8 =T8 Electronic Instant Start.
Riveted Endplates.
in carton
Ballast Factor .88
HB8 N=T8 Electronic Instant Start. For use in New York City.
RLS=Rotor-Lock Socket
Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start. (T8 Lamps Only)
(Additional options available)
High Ballast Factor 1.15-1.2
HR8 DIM=T8 Electronic Program
Start Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Start.
Low Ballast Factor .71–.77
HR8 =T8 Electronic Program Start.
ACCESSORIES
Ballast Factor .88
EQ-CLIP-U=T-BAR Safety
HR8 H=T8 Electronic Program Start.
Earthquake Clips(2)
High Ballast Factor 1.15-1.2
(1)
(2)
NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is
(3)
recommended for all 9/16" ceiling systems. Four required per fixture. Products also available
in non-US voltages and frequencies for international markets. Standard ballast configurations
(4)
(5)
also available. Not available when specifying emergencies, voltage must be specific. Specify
(6)
row configuration, type in catalog number when ordering complete fixture. Fixtures equipped
with “EL” option may require a 5-1/2" housing depth. If installing in field, must use low profile
(7)
battery pack. Other lamp options available.
For complete product data, reference the Fluorescent Specification binder. Specifications &
dimensions subject to change without notice. Consult your Cooper Lighting Representative for
availability and ordering information.
9
Ovation
Ovation 2' x 4' Photometrics
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
2RDI-232RP
Electronic Ballast
(2) F032/830/XP3 lamps
3100 lumens
Spacing criterion:
(II) 1.2 x mounting height,
(⊥) 1.4 x mounting height
Efficiency = 70.7%
Test Report:
2RDI232RP.IES
LER = FL61
Yearly Cost of 1000
lumens, 3000 hrs at .08
KWH = $3.93
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
84
77
69
63
57
53
48
45
42
39
36
84
73
63
55
49
43
39
35
32
29
27
84
70
58
49
42
37
32
29
26
23
21
84
67
54
44
37
32
28
24
21
19
17
82
75
67
61
56
51
47
44
41
38
36
82
71
62
54
48
42
38
34
31
29
27
82
68
57
48
42
36
32
28
25
23
21
82
66
53
44
37
32
27
24
21
19
17
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
79
68
59
52
46
41
37
33
30
28
26
75
66
57
50
44
39
36
32
30
27
25
72
63
55
48
43
38
34
31
29
26
24
71
58
48
40
34
29
25
22
20
18
16
79
66
55
47
41
35
31
28
25
23
21
79
64
52
43
36
31
27
24
21
19
17
75
64
54
46
40
35
31
27
25
22
20
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
1089
1811
3339
4384
4384
%Lamp
17.6
29.2
53.9
70.7
70.7
%Fixture
24.8
41.3
76.2
100.0
100.0
75
62
51
42
36
31
27
24
21
19
17
Average
0-Deg
cd/sm
1801
1693
1519
1284
953
Average
45-Deg
cd/sm
2068
2130
2142
1893
1397
Illuminance Estimator
72
61
52
45
39
34
30
27
24
22
20
72
60
50
42
35
31
27
24
21
19
17
Average
90-Deg
cd/sm
2279
2393
2380
2125
1545
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
1372
1367
1348
1316
1273
1216
1148
1071
984
889
785
678
564
448
335
232
139
58
0
45°
1372
1370
1357
1334
1302
1261
1212
1156
1092
1021
941
853
753
632
498
342
205
85
0
Across⊥
1372
1374
1365
1351
1332
1304
1271
1231
1182
1125
1053
958
846
702
539
384
228
94
0
Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD)
Based on 100 ft. x 100 ft. Open Room
Ballast Factor
0.77
0.88
1.0
1.15
FC LPD FC LPD FC LPD FC LPD
8' x 10'
37 0.58 42 0.64 48 0.74 55 0.88
10' x 10'
31 0.48 35 0.53 40 0.62 46 0.73
10' x 12'
25 0.38 28 0.42 32 0.50 37 0.58
Choose the spacing and ballast factor to determine the average footcandle and
watts per square foot values. All calculations are based on the published IESNA
Zonal Cavity Method and associated algorithms. Results are calculated from
the content of the manufacturer’s photometric files.
Fixture
Spacing
2RDI-232RP
Ordering Information
SAMPLE NUMBER: 2RDI-232RP-UNV-HB81-U
Width
2=2' Width
Series
RDI=Ovation
Series (Recessed
Direct/Indirect)
Trim Type
Leave Blank=Grid/Lay-in
(Standard)
Lamp Position
Leave Blank=Center Mounted
Lamps (Standard)
S=Side Mounted Lamps
ASY=Asymmetric
Number of Lamps
1=1 Lamp
2=2 Lamp
3=3 Lamp
(1)
Wattage
28T8=28W T8 (48") (7)
32=32W T8 (48")
Lamp Shield
X=Solid Matte White
RP=Round Perforated White Steel
RP/TBW=Round Perforated White
Steel w/Thin Blade White Baffle (1)
RP/PLI=Round Perforated White Steel
w/Semi-Specular Parabolic Baffle (1)
RP/PLMI=Round Perforated White
Steel w/Specular Parabolic Baffle (1)
RPD=Round Perforated Steel Below
Ceiling Lamp Shield (4)
RPD/TBW=Round Perforated Steel
Below Ceiling Lamp Shield w/Thin
Blade White Baffle
FLS=Frosted Lamp Shield (1)
SLS=Split Lamp Shield (1)
Debris Shield (5)
/DS=Debris Shield
Voltage (2)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277 (3)
Options
GL=Single Element Fuse
GM=Double Element Fuse
Flex=Flex Installed
EL=Emergency Installed
Lamps Installed (6)
Blank=No Lamps Installed
L8835=T8 Lamp, 28W and
32W, 3500K (7)
L8841=T8 Lamp, 28W and
32W, 4100K (7)
L8835HL=T8 Lamp, 32W,
3500K, 3100 Lumens
L8841HL=T8 Lamp, 32W,
4100K, 3100 Lumens
Ballast Type(2)
HPT8 Ballast
HB8 L=T8 Electronic Instant Start.
Low Ballast Factor .71–.77
HB8 =T8 Electronic Instant Start.
Ballast Factor .88
HB8 N=T8 Electronic Instant Start.
Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start.
High Ballast Factor 1.15-1.2
HR8 DIM=T8 Electronic Program
Start Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Start.
Low Ballast Factor .71–.77
HR8 =T8 Electronic Program Start.
Ballast Factor .88
HR8 H=T8 Electronic Program Start.
High Ballast Factor 1.15-1.2
(2)
NOTES: 2' x 2' and 2' x 4' Center Lamp Shield models only. Products also available in non-US voltages and frequencies for international markets. Standard ballast
(3)
(4)
(5)
configurations also available. Not available when specifying emergencies, voltage must be specific. Not available with emergency battery pack. Only compatible
(6)
(7)
(8)
with X, FLS and RP lamp shields. Other lamp options available. When utilizing 28W T8 lamps, HPT8 Ballast must be specified. An EQ Grid Clip is recommended for
all 9/16" ceiling systems. Four required per fixture.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
10
Options
RLS=Rotor-Lock
Socket (T8 Lamps
Only)
RIF1=Radio
Interference
Suppressor
REP=Riveted
Endplates
LSC=Lamp Shield
Cable
ST=Semi-Specular
Tannenbaum
(other options
available)
Packaging
U=Unit Pack
PALC=Palletized Fixtures
in Carton
ACCESSORIES
EQ=T-BAR Safety Earthquake Clips (8)
DF-24-W=Drywall Frame Kit (Order
Individually as Accessory)
Ovation 2' x 2' Photometrics
Coefficients of Utilization
2RDI-217RP
Electronic Ballast
(2) FO17/35K lamps
1300 lumens
Spacing criterion:
(II) 1.3 x mounting height,
(⊥) 1.4 x mounting height
Efficiency = 64.6%
Test Report:
2RDI217RP.IES
LER = FP
Yearly Cost of 1000
lumens, 3000 hrs at .08
KWH = $
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
77
70
64
58
53
49
45
42
39
36
34
77
67
59
51
45
41
36
33
30
28
25
77
64
54
46
40
35
31
27
25
22
20
77
62
50
42
35
30
26
23
21
19
17
75
69
62
57
52
48
44
41
38
35
33
75
66
57
50
45
40
36
33
30
27
25
75
63
53
45
39
34
30
27
24
22
20
75
61
50
41
35
30
26
23
21
19
17
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
72
63
55
48
43
38
35
31
29
26
24
69
60
53
47
41
37
34
31
28
26
24
66
58
51
45
40
36
33
30
27
25
23
65
54
45
38
32
28
24
21
19
17
15
72
61
52
44
38
34
30
27
24
22
20
72
59
49
41
35
30
26
23
21
19
17
69
59
50
43
37
33
29
26
24
21
20
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
453
746
1332
1680
1680
%Lamp
17.4
28.7
51.2
64.6
64.6
%Fixture
27.0
44.4
79.3
100.0
100.0
Average
0-Deg
cd/sm
1570
1421
1197
938
656
69
57
48
40
34
30
26
23
20
18
17
Average
45-Deg
cd/sm
1724
1679
1576
1264
827
66
57
49
42
37
32
29
26
23
21
19
66
56
46
39
34
29
36
23
20
18
17
Average
90-Deg
cd/sm
1841
1834
1692
1453
852
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
45°
Across⊥
576
576
569
555
536
511
482
447
408
365
318
576
575
570
558
542
522
497
469
437
401
361
576
576
571
562
550
533
513
490
461
428
391
268
217
166
120
80
45
19
0
317
270
219
163
108
63
24
0
346
293
235
177
124
70
24
0
Ordering Information
SAMPLE NUMBER: 2RDI-217RP-UNV-HB81-U
Width
2=2' Width
Wattage
17=17W T8 (24")
Series
RDI=Ovation
Series (Recessed
Direct/Indirect)
Lamp Shield
X=Solid Matte White
RP=Round Perforated White Steel
RP/TBW=Round Perforated White
Steel w/Thin Blade White Baffle (1)
RP/PLI=Round Perforated White Steel
w/Semi-Specular Parabolic Baffle (1)
RP/PLMI=Round Perforated White
Steel w/Specular Parabolic Baffle (1)
RPD=Round Perforated Steel Below
Ceiling Lamp Shield (4)
RPD/TBW=Round Perforated Steel
Below Ceiling Lamp Shield w/Thin
Blade White Baffle
FLS=Frosted Lamp Shield (1)
SLS=Split Lamp Shield (1)
Trim Type
Leave Blank=Grid/Lay-in
(Standard)
Lamp Position
Leave Blank=Center Mounted
Lamps (Standard)
S=Side Mounted Lamps
ASY=Asymmetric
Number of Lamps
1=1 Lamp
2=2 Lamp
3=3 Lamp
(1)
Voltage (2)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277 (3)
Options
GL=Single Element Fuse
GM=Double Element Fuse
Flex=Flex Installed
EL=Emergency Installed
Lamps Installed (6)
L8835=T8 Lamp,
17W and 32W, 3500K
L8841=T8 Lamp,
17W and 32W, 4100K
Ballast Type(2)
HPT8 Ballast
HB8 L=T8 Electronic Instant Start.
Low Ballast Factor .71–.77
HB8 =T8 Electronic Instant Start.
Ballast Factor .88
HB8 N=T8 Electronic Instant Start.
Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start.
High Ballast Factor 1.15-1.2
HR8 DIM=T8 Electronic Program
Start Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Start.
Low Ballast Factor .71–.77
HR8 =T8 Electronic Program Start.
Ballast Factor .88
HR8 H=T8 Electronic Program Start.
High Ballast Factor 1.15-1.2
Debris Shield (5)
/DS=Debris Shield
(2)
NOTES: 2' x 2' and 2' x 4' Center Lamp Shield models only. Products also available in non-US voltages and frequencies for international markets. Standard ballast
(3)
(4)
(5)
configurations also available. Not available when specifying emergencies, voltage must be specific. Not available with emergency battery pack. Only compatible
(6)
(7)
with X, FLS and RP lamp shields. Other lamp options available. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture.
Options
RLS=Rotor-Lock
Socket (T8 Lamps
Only)
RIF1=Radio
Interference
Suppressor
REP=Riveted
Endplates
LSC=Lamp Shield
Cable
ST=Semi-Specular
Tannenbaum
(other options
available)
Packaging
U=Unit Pack
PALC=Palletized Fixtures
in Carton
ACCESSORIES
EQ=T-BAR Safety Earthquake Clips (7)
DF-22-W=Drywall Frame Kit (Order
Individually as Accessory)
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
11
Accord
Accord 2' x 4' Photometrics
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
||
2AC-232-UNV-EB81
Electronic Ballast
(2) F32T8/835 Lamps
3100 Lumens each
Spacing criterion:
(II) 1.3 x mounting height,
(⊥) 1.5 x mounting height
Efficiency 84.9%
Test Report:
2AC-232-UNV-EB81.IES
LER = FL80 LPW
Yearly Cost of 1000
lumens, 3000 hrs at .08
KWH = $2.90
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
101 101 101 101
92 87 83 80
83
75
69
63
58
54
50
46
44
75
66
58
51
46
42
38
35
32
69
58
50
43
38
34
30
28
25
64
53
44
38
33
29
25
23
20
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
99 99
89 85
99
82
99
79
94
82
94 94
79 76
90 90
78 76
90
74
87 87 87
75 73 72
85
70
81
73
66
61
56
52
48
45
42
68
57
49
43
38
34
30
27
25
63
52
44
37
32
28
25
23
20
71
62
54
49
44
40
36
33
31
66
56
48
42
37
33
30
27
25
68
59
52
47
42
38
35
32
30
60
50
42
36
32
28
25
22
20
65
57
51
45
41
37
34
31
29
57
47
40
34
30
26
23
21
19
74
64
57
50
45
41
37
34
32
62
51
43
37
32
28
25
22
20
64
54
47
41
36
32
29
26
24
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
In Deg
45
55
65
75
85
Lumens
%Lamp
%Fixture
1279
2127
3942
5266
5266
20.6
34.3
63.6
84.9
84.9
24.3
40.4
74.9
100.0
100.0
Average
0-Deg
cd/sm
2186
2115
1996
1743
1331
Illuminance Estimator
62
53
46
40
36
32
29
26
24
Average
45-Deg
cd/sm
2425
2513
2651
2524
1939
59
49
42
36
31
28
25
22
20
Average
90-Deg
cd/sm
2628
2830
2902
2574
1857
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
45°
Across⊥
1613
1605
1585
1550
1501
1439
1365
1279
1183
1079
966
1613
1610
1594
1568
1530
1482
1424
1357
1281
1197
1106
1613
1616
1604
1585
1557
1520
1476
1424
1365
1297
1220
847
722
589
452
315
187
81
0
1006
898
782
634
456
280
118
0
1133
1021
856
663
465
277
113
0
Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD)
Based on 100 ft. x 100 ft. Open Room
Ballast Factor
0.77
0.88
1.0
1.15
FC LPD FC LPD FC LPD FC LPD
8' x 10'
44 0.58 51 0.64 57 0.74 66 0.88
10' x 10'
37 0.48 42 0.53 48 0.62 55 0.73
10' x 12'
30 0.38 34 0.42 39 0.50 45 0.58
Choose the spacing and ballast factor to determine the average footcandle and
watts per square foot values. All calculations are based on the published IESNA
Zonal Cavity Method and associated algorithms. Results are calculated from
the content of the manufacturer’s photometric files.
Fixture
Spacing
2AC-232
Ordering Information
SAMPLE NUMBER: 2AC-232-UNV-HB81-U
Rating
Blank=
Standard
NY=New York
Rated
ATW-SW4=
Chicago
Rated
Width
2=2' Width
Series
AC=Accord Series
(1)
Type
A=Air
(optional)
Number of
Lamps
(Not included)
2=2 Lamp
Wattage (Length)
28T8=28W T8 (48") (3)
32=32W T8 (48")
Shielding
Blank=Frosted Acrylic
SQP=Lens with
Square Pattern Insert
RDP=Lens with Round
Pattern Insert
Voltage (1)
UNV=Universal
Voltage 120-277
Lamps (2)
L8835=T8 Lamp, 28W
and 32W, 3500K (3)
L8841=T8 Lamp, 28W
and 32W, 4100K (3)
L8835HL=T8 Lamp,
32W, 3500K, 3100
Lumens
L8841HL=T8 Lamp,
32W, 4100K, 3100
Lumens
Options
GL=Single Element Fuse
GM=Double Element Fuse
Flex=Flex installed
EL=Emergency Installed
(2)
Packaging
Ballast Type (1)
U=Unit Pack
HPT8 Ballast
PALC=Job Pack,
HB8 L=T8 Electronic Instant Start.
in carton
Low Ballast Factor .71–.77
HB8 =T8 Electronic Instant Start. Ballast Factor .88
HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2
HR8 DIM=T8 Electronic Program Start Step Dimming.
Ballast Factor .88
HR8 L=T8 Electronic Program Start. Low Ballast Factor .71–.77
HR8 =T8 Electronic Program Start. Ballast Factor .88
HR8 H=T8 Electronic Program Start.
High Ballast Factor 1.15-1.2
(3)
NOTES: Products also available in non-US voltages and frequencies for international markets. Standard ballast configurations also available. Other lamp options available. When utilizing 28W T8 lamps, HPT8 Ballast
must be specified.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
12
Accord 2' x 2' Photometrics
Coefficients of Utilization
2AC-217
Electronic Ballast
(2) F17T8/TL841 lamps
1400 lumens
Spacing criterion:
(II) 1.2 x mounting height,
(⊥) 1.4 x mounting height
Efficiency 84.3%
Test Report: 2AC-217.IES
LER = FL-69 LPW
Yearly Cost of 1000
lumens, 3000 hrs at .08
KWH = $3.47
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
100
91
83
75
69
63
58
54
50
46
44
94
82
71
62
55
49
44
40
36
33
31
90
78
68
60
53
47
43
39
35
32
30
86
75
66
57
51
46
41
37
34
32
29
84
70
58
48
41
35
30
26
23
21
19
100
87
76
66
58
52
46
42
38
35
32
100
84
70
59
50
44
38
34
31
28
25
100
80
65
53
45
38
33
29
26
23
21
98
89
80
73
67
61
56
52
48
45
42
98
85
74
65
57
51
46
41
38
34
32
98
82
68
58
50
43
38
34
30
28
25
98
79
64
53
44
38
33
29
26
23
21
94
79
66
56
49
42
37
33
30
27
25
94
76
62
52
44
37
33
29
25
23
21
90
76
64
55
47
41
37
33
30
27
24
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
In Deg
45
55
65
75
85
Lumens
%Lamp
%Fixture
588
979
1813
2360
2360
21.0
35.0
64.7
84.3
84.3
24.9
41.5
76.8
100.0
100.0
Average
0-Deg
cd/sm
1830
1735
1595
1355
998
90
74
61
51
43
37
32
28
25
23
21
86
73
62
53
46
41
36
32
29
26
24
Average
45-Deg
cd/sm
2134
2190
2245
1901
1060
86
72
59
50
42
37
32
28
25
23
21
Average
90-Deg
cd/sm
2357
2526
2444
1775
1029
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
45°
Across⊥
737
735
724
707
682
652
616
574
527
476
422
737
735
729
719
703
683
658
628
594
555
511
737
737
735
729
720
707
690
669
643
613
576
366
308
248
188
129
76
32
0
462
408
349
274
181
99
34
0
533
475
380
266
169
92
33
0
Ordering Information
SAMPLE NUMBER: 2AC-217-UNV-HB81-U
Rating
Blank=
Standard
NY=New York
Rated
ATW-SW4=
Chicago
Rated
Width
2=2' Width
Series
AC=Accord Series
(1)
Type
A=Air
(optional)
Number of
Lamps
(Not included)
2=2 Lamp
Wattage (Length)
17=17W T8 (24")
Shielding
Blank=Frosted Acrylic
SQP=Lens with
Square Pattern Insert
RDP=Lens with Round
Pattern Insert
Lamps (2)
L8835=T8 Lamp,
17W, 3500K
L8841=T8 Lamp,
17W, 4100K
Voltage (1)
UNV=Universal
Voltage 120-277
Options
GL=Single Element Fuse
GM=Double Element Fuse
Flex=Flex installed
EL=Emergency Installed
Packaging
Ballast Type (1)
U=Unit Pack
HPT8 Ballast
PALC=Job Pack,
HB8 L=T8 Electronic Instant Start.
in carton
Low Ballast Factor .71–.77
HB8 =T8 Electronic Instant Start. Ballast Factor .88
HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2
HR8 DIM=T8 Electronic Program Start Step Dimming.
Ballast Factor .88
HR8 L=T8 Electronic Program Start. Low Ballast Factor .71–.77
HR8 =T8 Electronic Program Start. Ballast Factor .88
HR8 H=T8 Electronic Program Start.
High Ballast Factor 1.15-1.2
(2)
NOTES: Products also available in non-US voltages and frequencies for international markets. Standard ballast configurations also available. Other lamp options available.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
13
Cooper Lighting, LLC.
Customer First Center
1121 Highway 74 South
Peachtree City, GA 30269
International Sales, USA
Cooper Lighting, LLC.
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
F: 770-486-4801
P: 770-486-4800
F: 770-486-4801
www.cooperlighting.com
Canada
Cooper Lighting, LLC.
5925 McLaughlin Road
Mississauga, Ontario L5R 1B8
P: 905-507-4000
F: 905-568-7049
Domestic Facilities
Cranbury, New Jersey
Elk Grove Village, Illinois
Irving, Texas
Ontario, California
Peachtree City, Georgia
Canadian Facility
Calgary, Alberta T2E 7V9
Mississauga, Ontario L5R 1B8
Cooper Lighting and Metalux are valuable trademarks of Cooper Industries in the United States and other countries.
You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries.
Cooper Industries plc
600 Travis, Ste. 5600
Houston, TX 77002-1001
P: 713-209-8400
www.cooperindustries.com
ADF092089
Printed in USA
The Cooper Lighting Family
Halo
Metalux
Lumark
Sure-Lites
Neo-Ray
Corelite
Portfolio
Iris
Shaper
io
Lumière
Invue
McGraw-Edison
Streetworks
Fail-Safe
PDS
MWS
RSA
Ametrix
Download