OpticaHP Series 2HP Series Accord Series Ovation Series High Performance T8 Solutions Introduction Enhanced Illumination…. Lower Operating Costs Working today to reduce energy costs does not mean that the quality of the lighting has to be sacrificed. Metalux has combined the latest T8 lamp and ballast technology with the newest recessed architectural products that not only enhance the work environment but will lower operating and maintenance costs. The Accord , Ovation , OpticaHP and 2HP families provide exciting alternatives to traditional fluorescent recessed lighting products. Each family balances the lighting in the vertical and horizontal zones to give the space a softer, more comfortable feel. The combination of luminaire efficiency and a high performance T8 system allows the flexibility to meet a wide range of light levels with a two lamp system while providing significant reduction in energy usage. TM TM T8 Index Product Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Product Comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Retrofit Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 OpticaHP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 2HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Ovation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Accord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Accord TM Distributing light throughout the space, the Accord eliminates uneven distribution and makes the room feel comfortable and inviting. It’s smooth curved surfaces and matte white finish provide a design that is attractive but subtle in application. OpticaHP Building on the Metalux Optica Series, the OpticaHP family combines a precision faceted blade design with new high efficient T8 technology to produce optimal performance and aesthetic styling. Ovation TM Carefully balanced design elements combine to provide an efficient and inviting high performance alternative to traditional general lighting. The Ovation utilizes a matte white indirect reflector and a perforated direct lamp shield to provide optimum brightness control. 2HP Precision formed white or semi-specular louver that creates a soft, even distribution while delivering high efficiency. The 2HP luminaire is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for increased application versatility. 1 Product Comparison Maximizing Energy Savings Combine HPT8 Step Dimming Ballasts with Cooper Control products for optimal energy savings. High Performance T8 systems allow the flexibility to tune the light output and energy usage by changing the luminaire ballast factor to adapt to needed light levels and energy requirements within an application. Using fewer lamps will help reduce future maintenance and recycling costs. HPT8 Lamp Advantages HPT8 Ballast Advantages • Higher Lumens • Longer Life • Higher CRI Rating • No Issues with Temperature or Dimming • Reduced Energy Consumption • Flexible Light Output* • Instant and Program Start Designs HPT8 Lamping Advantages (4', T8 Lamps) Parabolic Comparison (3 Lamp vs. 2 Lamp HPT8) 32 Watt Standard 32 Watt High Performance 25/28/30 Watt Energy Saving 2750+ 3100 2500+ 20,000+ 24,000+ 24,000+ 0 -20 60 CRI >75 >80 >80 Emergency Yes Yes Limited Dimming Yes Yes Limited Initial Lumens Lamp Life Starting Temp. (°F) Ballast Ballast Factor Light Levels Energy Savings HB81L, HR81L .77 – .77 M L HB81, HR81 .88 = L HB81N 1.0 = L HB81H, HR81H 1.15 – 1.2 L M *Also available with Step Dimming Ballasts for additional light output control. Standard Parabolic OpticaHP Parabolic (3) 32W T8 Lamps, 12 Fixtures Electronic Ballast (.87 Ballast Factor) 83 Watts per Fixture (2) 32W T8 Lamps, 12 Fixtures Electronic Ballast (1.0 Ballast Factor) 62 Watts per Fixture Based on: Room Size: 50' x 30' Ceiling Height: 10' Work Plane: 2.5' Reflectances: 80/50/20 36 34 IES* 16 .67 Watts/Sq.ft. 2 Horizontal Vertical Footcandles Footcandles IES* *IES recommends 30–35 footcandles in open office environments. 19 0.50 Watts/Sq.ft. Horizontal Vertical Footcandles Footcandles Standard Troffer Accord (4) 32W T8 Lamps, 12 Fixtures Electronic Ballast (.87 Ballast Factor) 122 Watts per Fixture (2) 32W T8 Lamps, 12 Fixtures Electronic Ballast (1.20 Ballast Factor) 77 Watts per Fixture Based on: Room Size: 50' x 30' Ceiling Height: 10' Work Plane: 2.5' Reflectances: 80/50/20 50 IES* Watts/Sq.ft. 41 23 IES* *IES recommends 30–35 footcandles in open office environments. 0.98 Horizontal Vertical Footcandles Footcandles TM 24 0.62 Watts/Sq.ft. Horizontal Vertical Footcandles Footcandles 3 Retrofit Kit OpticaHP Retrofit Kit The OpticaHP retrofit kit has been designed to balance performance and energy savings in an environmentally friendly solution. The kit not only offers a visual improvement over traditional parabolics, there will be significant savings from lowered energy consumption and reduced maintenance. The OpticaHP is readily available in unit packs and, in order to optimize savings and further reduce waste, the kits are also available in bulk pack configurations that are recommended for larger jobs. Key Advantages of the OpticaHP Retrofit Kit: • Lower Energy Costs: Save up to 40% Compared to Standard 3-Lamp Parabolics • Improved Lighting: Even Delivery of Light that Eliminates Shadows • Less Waste: Reusing Existing Housing results in Less Handling and a Lower Disposal Cost • Pre-Wired Kits: Avoids Additional Time & Expense of Field Wiring OpticaHP Retrofit Kit Installation 1. Install the Socket Track Flange. 4 2. Secure Ballast and Socket Tracks. 3. Attach Supply Wires to Quick Disconnect. Lighting before OpticaHP • Efficiency: 69.1% • Input Watts: 86 • Lumens/Watt: .59.4 • Vertical Illumination: 1:2.5 • Lamp Life: 20,000 hours • CRI (Color Rendering Index): >75 Lighting with OpticaHP • Efficiency: 87.6% • Input Watts: 53 • Lumens/Watt: 88.5 • Vertical Illumination: 1:1.9 • Lamp Life: 24,000+ hours • CRI (Color Rendering Index): >80 Ordering Information SAMPLE NUMBER: 2OPRK-232-UNV-HB81L-4 Width 2=2' Nominal Number of Lamps 2=2 lamps (Not Included) Series OPRK=Optica HP Retrofit Kit Wattage (Length) 17=17W T8 (24") 32=32W T8 (48") 28T8=28W T8 (48") (2) Voltage (1) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 Ballast Type (1) HPT8 Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor >.71–.77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .71–.77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 (1) Packaging B=Bulk Pack, Palletized (48" – 20 per Pallet) (24" – 40 per Pallet) U=Unit Pack (For large jobs order Bulk Pack for maximum savings and reduced packaging waste) (2) NOTES: Products also available in non-US voltages and frequencies for international markets. Standard ballast configurations also available. When utilizing 28W T8 lamps, HPT8 Ballast must be specified. For complete product data, go to www.metalux-lighting.com. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. 4. Insert Reflector and attach to Socket Tracks (install lamps). 5. Position Louver Hinges into Existing Slots. 6. Secure Louver by engaging Spring Latches. 5 OpticaHP OpticaHP 2' x 4' Photometrics Candela Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 2OPG-232-UNV Electronic Ballast (2) F32T8 32W lamps 3100 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency = 87.1% Test Report: 2OPG-232FB26W.IES LER = FP-84 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.86 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 104 95 87 79 72 66 61 57 53 49 46 97 85 75 66 59 52 47 43 39 36 33 93 82 72 64 56 51 46 42 38 35 32 89 79 69 61 55 49 44 40 37 34 32 87 74 62 52 44 38 33 29 26 23 21 104 91 80 70 62 55 50 45 41 37 35 104 87 74 63 54 47 42 37 33 30 28 104 84 69 57 48 42 36 32 28 25 23 101 101 101 101 93 89 86 83 84 78 73 68 77 69 62 57 70 61 54 48 65 54 47 41 60 49 41 36 55 44 37 32 51 40 33 28 48 37 30 25 45 34 27 23 97 83 70 60 52 46 41 36 33 30 27 97 80 66 56 47 41 36 32 28 25 23 93 80 68 59 51 45 40 36 32 29 27 93 78 65 55 47 40 35 31 28 25 23 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 90-180 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens %Lamp 1463 2425 4397 5400 0 5400 23.6 39.1 70.9 87.1 0 87.1 %Fixture 27.1 44.9 81.4 100.0 0 100 Height Along 8.5’ 10.0’ 60 66 59 60 55 56 63 64 58 58 Illuminance Estimator 89 77 66 57 50 44 39 35 32 29 26 89 75 64 54 46 40 35 31 28 25 23 Height Across 8.5’ 10.0’ 60 63 59 61 57 58 63 64 59 59 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 45° Across⊥ 1825 1823 1797 1755 1688 1607 1508 1397 1273 1141 1001 1825 1834 1823 1795 1751 1690 1617 1529 1432 1327 1206 1825 1844 1848 1838 1816 1781 1737 1689 1624 1530 1405 857 711 562 407 263 155 73 0 1062 896 720 480 250 149 68 0 1260 1051 649 333 235 145 62 0 Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD) Based on 100 ft. x 100 ft. Open Room Ballast Factor 0.77 0.88 1.0 1.15 FC LPD FC LPD FC LPD FC LPD 8' x 10' 46 0.58 52 0.64 60 0.74 69 0.88 10' x 10' 38 0.48 43 0.53 49 0.62 57 0.73 10' x 12' 31 0.38 35 0.42 40 0.50 46 0.58 Choose the spacing and ballast factor to determine the average footcandle and watts per square foot values. All calculations are based on the published IESNA Zonal Cavity Method and associated algorithms. Results are calculated from the content of the manufacturer’s photometric files. Fixture Spacing 2OPG-232FB26W Ordering Information SAMPLE NUMBER: 2OPG-232FB26W-UNV-HB81-U Rating Blank= Standard Number of Lamps 2=2 Lamps Width 2=2' Width Wattage (Length) 28T8=28W T8 (48") (4) 32=32W T8 (48") OP=Optica HP Series Trim Type G=Grid/Lay-in (Standard) (6) F=Aluminum Flange Trim (7) MZ=Modular Trim Cross Blade FB=Faceted Blade Cell Configuration 26=2 Rows of 6, 12 Cell Louver Finish W=Matte White Option – Aluminum Flange Trim (7) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row (1) Voltage (2) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (3) Options Packaging Ballast Type (2) R=Internal Reflector U=Unit Pack HPT8 Ballast PAL=Job Pack, HB8 L=T8 Electronic Instant Start. Low Ballast Factor .71–.77 out of carton HB8 =T8 Electronic Instant Start. Ballast Factor .88 PALC=Job Pack, HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 in carton HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .71–.77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 Options GL=Single Element Fuse GM=Double Element Fuse Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (5) Lamps Installed (8) Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K (4) L8841=T8 Lamp, 28W and 32W, 4100K (4) L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(1) (2) NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Products also available in non-US voltages and frequencies for international markets. Standard ballast configurations (3) (4) (5) also available. Not available when specifying emergencies, voltage must be specific. When utilizing 28W T8 lamps, HPT8 Ballast must be specified. Fixtures equipped with “EL” option may require a 5-1/2" housing (6) (7) (8) depth. If installing in field, must use low profile battery pack. Louver is recessd by 5/16" in Concealed T or Slot Grid. Specify row configuration, type in catalog number when ordering complete fixture. Other lamp options available. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. 6 OpticaHP 2' x 2' Photometrics Coefficients of Utilization rc 2OPG-217FB23MWUNV-EB81-U Electronic Ballast (2) F17T8 17W lamps 1450 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency = 82.5% Test Report: OPG-217FB23MW.IES LER = FP-65 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.69 rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 98 90 82 75 69 63 58 54 50 47 44 98 87 76 67 59 53 48 43 39 36 33 98 83 70 60 52 46 40 36 32 29 27 98 80 66 55 47 40 35 31 28 25 22 20% 50% 30% 10% 70 50 30 10 50 30 10 50 30 10 50 30 10 0 96 88 80 73 67 62 57 53 49 46 43 92 81 71 63 56 50 45 41 38 35 32 88 78 69 61 54 49 44 40 37 34 31 84 75 66 59 52 47 43 39 36 33 30 82 70 59 50 43 37 32 29 25 23 21 96 85 74 65 58 52 47 42 39 36 33 96 82 69 59 51 45 40 36 32 29 27 96 79 65 55 46 40 35 31 27 25 22 92 79 67 58 50 44 39 35 32 29 26 92 76 64 54 46 40 35 31 27 25 22 88 76 65 56 49 43 38 34 31 28 26 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 90-180 0-180 Angle In Deg 45 55 65 75 85 Lumens 672 1108 1982 2392 0 2392 0% %Lamp 23.2 38.2 68.3 82.5 0 82.5 %Fixture 28.1 46.3 82.9 100.0 0 100.0 88 74 62 53 45 39 34 30 27 24 22 Average 0-Deg cd/sm 2361 2121 1775 1315 986 84 73 63 55 48 42 38 34 31 28 26 Average 45-Deg cd/sm 2772 2657 2339 1303 986 84 72 61 52 44 39 34 30 27 24 22 Average 90-Deg cd/sm 3249 3285 2010 1328 910 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 45° Across⊥ 862 854 835 809 774 731 682 626 565 505 438 368 298 227 159 103 61 26 0 862 857 844 827 802 771 734 691 643 593 531 461 381 299 183 102 60 26 0 862 860 857 847 835 817 798 772 740 695 634 570 462 257 142 104 61 24 0 Ordering Information SAMPLE NUMBER: 2OPG-217FB23W-UNV-HB81-U Rating Blank= Standard Number of Lamps 2=2 Lamps Width 2=2' Width Wattage (Length) 17=17W T8 (24") U1-5/8=31W T8 (24") OP=Optica HP Series Trim Type G=Grid/Lay-in (Standard) (6) F=Aluminum Flange Trim (5) MZ=Modular Trim Cross Blade FB=Faceted Blade Cell Configuration 23=2 Rows of 3, 6 Cell Louver Finish W=Matte White Option – Aluminum Flange Trim (5) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row (1) Voltage (2) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (3) Options Packaging Ballast Type (2) R=Internal Reflector U=Unit Pack HPT8 Ballast (Not available for PAL=Job Pack, HB8 L=T8 Electronic Instant Start. U1-5/8 lamp) out of carton Low Ballast Factor .71–.77 PALC=Job Pack, HB8 =T8 Electronic Instant Start. Ballast Factor .88 in carton HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .71–.77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (4) Lamps Installed (7) L8835=T8 Lamp, 17W, 3500K L8841=T8 Lamp, 17W, 4100K ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(1) (2) NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Products also available in non-US voltages and frequencies for international markets. Standard ballast configurations (3) (4) also available. Not available when specifying emergencies, voltage must be specific. Fixtures equipped with “EL” option may require a 5-1/2" housing depth. If installing in field, must use low profile battery pack. (5) (6) (7) Specify row configuration, type in catalog number when ordering complete fixture. Louver is recessed by 5/16" in Concealed T or Slot Grid. Other lamp options available. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. 7 2HP 2HP 2' x 4' Photometrics Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 101 93 84 77 71 65 60 55 52 48 45 101 89 78 68 61 54 49 44 40 37 34 101 85 72 62 53 47 41 37 33 30 27 101 82 67 56 48 41 36 31 28 25 23 99 90 82 75 69 63 58 54 50 47 44 99 87 76 67 59 53 48 43 40 36 33 99 84 71 61 53 46 41 36 33 30 27 99 81 67 56 47 41 35 31 28 25 23 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 94 83 73 65 57 51 46 42 38 35 33 90 80 70 62 55 50 45 41 37 34 32 87 77 68 60 54 48 43 40 36 33 31 85 72 60 51 44 38 33 29 26 23 21 94 81 69 59 51 45 40 36 32 29 27 94 78 65 55 47 40 35 31 28 25 23 90 78 67 58 50 44 39 35 32 29 26 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle In Deg 45 55 65 75 85 Lumens 1323 2200 3975 4833 4833 %Lamp 23.3 38.6 69.7 84.8 84.8 %Fixture 27.5 45.5 82.3 100.0 100.0 90 76 64 54 46 40 35 31 28 25 22 Average 0-Deg cd/sm 2331 2123 1782 1191 945 Illuminance Estimator Choose the spacing and ballast factor to determine the average footcandle and watts per square foot values. All calculations are based on the published IESNA Zonal Cavity Method and associated algorithms. Results are calculated from the content of the manufacturer’s photometric files. 87 75 65 56 49 43 38 35 31 28 26 Average 45-Deg cd/sm 2792 2747 2430 1318 1059 87 74 62 53 45 39 35 31 27 25 22 Average 90-Deg cd/sm 3312 3333 2266 1350 1172 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II Across⊥ 45° 1674 1660 1625 1571 1502 1422 1331 1231 1120 1000 870 1674 1673 1665 1646 1603 1543 1462 1374 1288 1198 1090 1674 1680 1697 1694 1667 1619 1585 1552 1501 1421 1306 739 604 457 316 187 112 50 0 956 797 623 400 207 123 56 0 1160 967 581 301 212 135 62 0 Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD) Based on 100 ft. x 100 ft. Open Room 2HP2GX-232W26P Ballast Factor 0.77 0.88 1.0 1.15 FC LPD FC LPD FC LPD FC LPD 8' x 10' 45 0.58 51 0.64 58 0.74 67 0.88 10' x 10' 37 0.48 42 0.53 48 0.62 55 0.73 10' x 12' 30 0.38 34 0.42 39 0.50 45 0.58 Fixture Spacing 2HP2-232W26P Electronic Ballast (2) F32T8/840 lamps 2850 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency = 84.8% Test Report: 2HP2-232W26P.IES LER = FP-79 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.04 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Ordering Information SAMPLE NUMBER: 2HP2GX-232W26P-UNV-HB81H-U Rating Blank= Standard NY=New York City Rated ATW-SW4= Chicago Rated HR=Heat Removal (1) Width 2=2' Width H=High Performance P=Paralux Louver 2=2" Louver Depth Trim Type G=Grid/Lay-in (Standard) G or T=Concealed T G or T=Slot Grid (2) F=Aluminum Flange Trim (5) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) 8 Number of Lamps 2 or 3 lamps Wattage (Length) 28T8=28W T8 (48") (5) 32=32W T8 (48") Louver Color W=White (Standard) S=Silver Cell Configuration 26=2 Rows of 6, 12 Cell (2' x 4') 36=3 Rows of 6, 18 Cell (2' x 4') Louver Finish P=Painted White (Standard) I=Semi-Specular/Haze (Low Iridescent) (Silver Only) Option – Aluminum Flange Trim (7) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4) Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (6) Lamps Installed (8) Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K (5) L8841=T8 Lamp, 28W and 32W, 4100K (5) L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens Ballast Type (3) HPT8 Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .71–.77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .71–.77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 (1) Options Packaging RIF1=Radio U=Unit Pack Interference PAL=Job Pack, Suppressor out of carton 20GA/REP=20 Gauge PALC=Job Pack, Riveted Endplates. in carton For use in New York City. RLS=Rotor-Lock Socket (T8 Lamps Only) (Additional options available) ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(2) (2) NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid (3) Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Products also available in non-US voltages and frequencies for international markets. Standard ballast (4) configurations also available. Not available when specifying emergencies, voltage must (5) (6) be specific. When utilizing 28W T8 lamps, HPT8 Ballast must be specified. Fixtures equipped with “EL” option may require a 5-1/2" housing depth. If installing in field, must use (7) low profile battery pack. Specify row configuration, type in catalog number when ordering (8) complete fixture. Other lamp options available. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. 2HP 2' x 2' Photometrics Coefficients of Utilization 2HP2-217W23P Electronic Ballast (2) F17T8/TL835 lamps 1450 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency = 81.9% Test Report: 2HP2-217W23P.IES LER = FP67 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.58 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 97 90 82 75 68 63 58 54 50 47 44 97 86 75 66 59 53 47 43 39 36 33 97 83 70 60 52 46 40 36 32 29 27 97 80 65 55 47 40 35 31 28 25 23 95 87 80 73 67 61 57 53 49 46 43 95 84 74 65 58 52 47 42 39 36 33 95 81 69 59 51 45 40 36 32 29 27 95 78 65 54 46 40 35 31 28 25 22 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 91 81 71 63 56 50 45 41 38 35 32 87 77 68 60 54 48 44 40 37 34 31 84 74 66 58 52 47 43 39 36 33 31 82 70 59 50 43 37 32 29 25 23 21 91 78 67 58 50 44 39 35 32 29 26 91 76 63 53 46 40 35 31 27 25 22 87 75 65 56 49 43 38 34 31 28 26 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 90-180 0-180 Angle In Deg 45 55 65 75 85 Lumens 683 1112 1963 2374 0 2374 %Lamp 23.6 38.4 67.7 81.9 0 81.9 %Fixture 28.8 46.9 82.7 100.0 0 100.0 87 74 62 52 45 39 34 30 27 25 22 Average 0-Deg cd/sm 2541 2296 1891 1245 1141 84 73 63 55 48 42 38 34 31 28 26 Average 45-Deg cd/sm 2750 2655 2394 1312 1180 84 71 60 51 44 39 34 30 27 24 22 Average 90-Deg cd/sm 3220 3288 2337 1232 1141 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 45° Across⊥ 883 879 861 834 798 755 706 650 589 524 455 883 880 871 848 819 786 736 676 619 567 510 883 885 880 864 844 803 763 736 705 664 608 384 310 233 158 94 59 29 0 444 370 295 195 99 61 30 0 550 467 288 130 93 63 29 0 Ordering Information SAMPLE NUMBER: 2HP2GX-217W23P-UNV-HB81H-U Rating Blank= Standard NY=New York City Rated ATW-SW4= Chicago Rated HR=Heat Removal (1) Width 2=2' Width H=High Performance P=Paralux Louver 2=2" Louver Depth Trim Type G=Grid/Lay-in (Standard) G or T=Concealed T G or T=Slot Grid (2) F=Aluminum Flange Trim (5) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) Number of Lamps 2 lamps Wattage (Length) 17=17W T8 (24") U1-5/8=31W T8 (24") Louver Color W=White (Standard) S=Silver Cell Configuration 23=2 Rows of 3, 6 Cell (2' x 2') 33=3 Rows of 3, 9 Cell (2' x 2') Louver Finish P=Painted White (Standard) I=Semi-Specular/Haze (Low Iridescent) (Silver Only) Option – Aluminum Flange Trim (5) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4) Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (6) Lamps Installed (7) Blank=No Lamps Installed L8835=T8 Lamp, 17W, 3500K L8841=T8 Lamp, 17W, 4100K Options Packaging Ballast Type (3) RIF1=Radio U=Unit Pack HPT8 Ballast Interference PAL=Job Pack, HB8 L=T8 Electronic Instant Start. Suppressor out of carton Low Ballast Factor .71–.77 20GA/REP=20 Gauge PALC=Job Pack, HB8 =T8 Electronic Instant Start. Riveted Endplates. in carton Ballast Factor .88 HB8 N=T8 Electronic Instant Start. For use in New York City. RLS=Rotor-Lock Socket Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. (T8 Lamps Only) (Additional options available) High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .71–.77 HR8 =T8 Electronic Program Start. ACCESSORIES Ballast Factor .88 EQ-CLIP-U=T-BAR Safety HR8 H=T8 Electronic Program Start. Earthquake Clips(2) High Ballast Factor 1.15-1.2 (1) (2) NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is (3) recommended for all 9/16" ceiling systems. Four required per fixture. Products also available in non-US voltages and frequencies for international markets. Standard ballast configurations (4) (5) also available. Not available when specifying emergencies, voltage must be specific. Specify (6) row configuration, type in catalog number when ordering complete fixture. Fixtures equipped with “EL” option may require a 5-1/2" housing depth. If installing in field, must use low profile (7) battery pack. Other lamp options available. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. 9 Ovation Ovation 2' x 4' Photometrics Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 2RDI-232RP Electronic Ballast (2) F032/830/XP3 lamps 3100 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency = 70.7% Test Report: 2RDI232RP.IES LER = FL61 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.93 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 84 77 69 63 57 53 48 45 42 39 36 84 73 63 55 49 43 39 35 32 29 27 84 70 58 49 42 37 32 29 26 23 21 84 67 54 44 37 32 28 24 21 19 17 82 75 67 61 56 51 47 44 41 38 36 82 71 62 54 48 42 38 34 31 29 27 82 68 57 48 42 36 32 28 25 23 21 82 66 53 44 37 32 27 24 21 19 17 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 79 68 59 52 46 41 37 33 30 28 26 75 66 57 50 44 39 36 32 30 27 25 72 63 55 48 43 38 34 31 29 26 24 71 58 48 40 34 29 25 22 20 18 16 79 66 55 47 41 35 31 28 25 23 21 79 64 52 43 36 31 27 24 21 19 17 75 64 54 46 40 35 31 27 25 22 20 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 1089 1811 3339 4384 4384 %Lamp 17.6 29.2 53.9 70.7 70.7 %Fixture 24.8 41.3 76.2 100.0 100.0 75 62 51 42 36 31 27 24 21 19 17 Average 0-Deg cd/sm 1801 1693 1519 1284 953 Average 45-Deg cd/sm 2068 2130 2142 1893 1397 Illuminance Estimator 72 61 52 45 39 34 30 27 24 22 20 72 60 50 42 35 31 27 24 21 19 17 Average 90-Deg cd/sm 2279 2393 2380 2125 1545 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1372 1367 1348 1316 1273 1216 1148 1071 984 889 785 678 564 448 335 232 139 58 0 45° 1372 1370 1357 1334 1302 1261 1212 1156 1092 1021 941 853 753 632 498 342 205 85 0 Across⊥ 1372 1374 1365 1351 1332 1304 1271 1231 1182 1125 1053 958 846 702 539 384 228 94 0 Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD) Based on 100 ft. x 100 ft. Open Room Ballast Factor 0.77 0.88 1.0 1.15 FC LPD FC LPD FC LPD FC LPD 8' x 10' 37 0.58 42 0.64 48 0.74 55 0.88 10' x 10' 31 0.48 35 0.53 40 0.62 46 0.73 10' x 12' 25 0.38 28 0.42 32 0.50 37 0.58 Choose the spacing and ballast factor to determine the average footcandle and watts per square foot values. All calculations are based on the published IESNA Zonal Cavity Method and associated algorithms. Results are calculated from the content of the manufacturer’s photometric files. Fixture Spacing 2RDI-232RP Ordering Information SAMPLE NUMBER: 2RDI-232RP-UNV-HB81-U Width 2=2' Width Series RDI=Ovation Series (Recessed Direct/Indirect) Trim Type Leave Blank=Grid/Lay-in (Standard) Lamp Position Leave Blank=Center Mounted Lamps (Standard) S=Side Mounted Lamps ASY=Asymmetric Number of Lamps 1=1 Lamp 2=2 Lamp 3=3 Lamp (1) Wattage 28T8=28W T8 (48") (7) 32=32W T8 (48") Lamp Shield X=Solid Matte White RP=Round Perforated White Steel RP/TBW=Round Perforated White Steel w/Thin Blade White Baffle (1) RP/PLI=Round Perforated White Steel w/Semi-Specular Parabolic Baffle (1) RP/PLMI=Round Perforated White Steel w/Specular Parabolic Baffle (1) RPD=Round Perforated Steel Below Ceiling Lamp Shield (4) RPD/TBW=Round Perforated Steel Below Ceiling Lamp Shield w/Thin Blade White Baffle FLS=Frosted Lamp Shield (1) SLS=Split Lamp Shield (1) Debris Shield (5) /DS=Debris Shield Voltage (2) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (3) Options GL=Single Element Fuse GM=Double Element Fuse Flex=Flex Installed EL=Emergency Installed Lamps Installed (6) Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K (7) L8841=T8 Lamp, 28W and 32W, 4100K (7) L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens Ballast Type(2) HPT8 Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .71–.77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .71–.77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 (2) NOTES: 2' x 2' and 2' x 4' Center Lamp Shield models only. Products also available in non-US voltages and frequencies for international markets. Standard ballast (3) (4) (5) configurations also available. Not available when specifying emergencies, voltage must be specific. Not available with emergency battery pack. Only compatible (6) (7) (8) with X, FLS and RP lamp shields. Other lamp options available. When utilizing 28W T8 lamps, HPT8 Ballast must be specified. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. 10 Options RLS=Rotor-Lock Socket (T8 Lamps Only) RIF1=Radio Interference Suppressor REP=Riveted Endplates LSC=Lamp Shield Cable ST=Semi-Specular Tannenbaum (other options available) Packaging U=Unit Pack PALC=Palletized Fixtures in Carton ACCESSORIES EQ=T-BAR Safety Earthquake Clips (8) DF-24-W=Drywall Frame Kit (Order Individually as Accessory) Ovation 2' x 2' Photometrics Coefficients of Utilization 2RDI-217RP Electronic Ballast (2) FO17/35K lamps 1300 lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.4 x mounting height Efficiency = 64.6% Test Report: 2RDI217RP.IES LER = FP Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $ rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 77 70 64 58 53 49 45 42 39 36 34 77 67 59 51 45 41 36 33 30 28 25 77 64 54 46 40 35 31 27 25 22 20 77 62 50 42 35 30 26 23 21 19 17 75 69 62 57 52 48 44 41 38 35 33 75 66 57 50 45 40 36 33 30 27 25 75 63 53 45 39 34 30 27 24 22 20 75 61 50 41 35 30 26 23 21 19 17 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 72 63 55 48 43 38 35 31 29 26 24 69 60 53 47 41 37 34 31 28 26 24 66 58 51 45 40 36 33 30 27 25 23 65 54 45 38 32 28 24 21 19 17 15 72 61 52 44 38 34 30 27 24 22 20 72 59 49 41 35 30 26 23 21 19 17 69 59 50 43 37 33 29 26 24 21 20 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 453 746 1332 1680 1680 %Lamp 17.4 28.7 51.2 64.6 64.6 %Fixture 27.0 44.4 79.3 100.0 100.0 Average 0-Deg cd/sm 1570 1421 1197 938 656 69 57 48 40 34 30 26 23 20 18 17 Average 45-Deg cd/sm 1724 1679 1576 1264 827 66 57 49 42 37 32 29 26 23 21 19 66 56 46 39 34 29 36 23 20 18 17 Average 90-Deg cd/sm 1841 1834 1692 1453 852 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 45° Across⊥ 576 576 569 555 536 511 482 447 408 365 318 576 575 570 558 542 522 497 469 437 401 361 576 576 571 562 550 533 513 490 461 428 391 268 217 166 120 80 45 19 0 317 270 219 163 108 63 24 0 346 293 235 177 124 70 24 0 Ordering Information SAMPLE NUMBER: 2RDI-217RP-UNV-HB81-U Width 2=2' Width Wattage 17=17W T8 (24") Series RDI=Ovation Series (Recessed Direct/Indirect) Lamp Shield X=Solid Matte White RP=Round Perforated White Steel RP/TBW=Round Perforated White Steel w/Thin Blade White Baffle (1) RP/PLI=Round Perforated White Steel w/Semi-Specular Parabolic Baffle (1) RP/PLMI=Round Perforated White Steel w/Specular Parabolic Baffle (1) RPD=Round Perforated Steel Below Ceiling Lamp Shield (4) RPD/TBW=Round Perforated Steel Below Ceiling Lamp Shield w/Thin Blade White Baffle FLS=Frosted Lamp Shield (1) SLS=Split Lamp Shield (1) Trim Type Leave Blank=Grid/Lay-in (Standard) Lamp Position Leave Blank=Center Mounted Lamps (Standard) S=Side Mounted Lamps ASY=Asymmetric Number of Lamps 1=1 Lamp 2=2 Lamp 3=3 Lamp (1) Voltage (2) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (3) Options GL=Single Element Fuse GM=Double Element Fuse Flex=Flex Installed EL=Emergency Installed Lamps Installed (6) L8835=T8 Lamp, 17W and 32W, 3500K L8841=T8 Lamp, 17W and 32W, 4100K Ballast Type(2) HPT8 Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .71–.77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .71–.77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 Debris Shield (5) /DS=Debris Shield (2) NOTES: 2' x 2' and 2' x 4' Center Lamp Shield models only. Products also available in non-US voltages and frequencies for international markets. Standard ballast (3) (4) (5) configurations also available. Not available when specifying emergencies, voltage must be specific. Not available with emergency battery pack. Only compatible (6) (7) with X, FLS and RP lamp shields. Other lamp options available. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Options RLS=Rotor-Lock Socket (T8 Lamps Only) RIF1=Radio Interference Suppressor REP=Riveted Endplates LSC=Lamp Shield Cable ST=Semi-Specular Tannenbaum (other options available) Packaging U=Unit Pack PALC=Palletized Fixtures in Carton ACCESSORIES EQ=T-BAR Safety Earthquake Clips (7) DF-22-W=Drywall Frame Kit (Order Individually as Accessory) For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. 11 Accord Accord 2' x 4' Photometrics Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 || 2AC-232-UNV-EB81 Electronic Ballast (2) F32T8/835 Lamps 3100 Lumens each Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.5 x mounting height Efficiency 84.9% Test Report: 2AC-232-UNV-EB81.IES LER = FL80 LPW Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.90 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 101 101 101 101 92 87 83 80 83 75 69 63 58 54 50 46 44 75 66 58 51 46 42 38 35 32 69 58 50 43 38 34 30 28 25 64 53 44 38 33 29 25 23 20 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 99 99 89 85 99 82 99 79 94 82 94 94 79 76 90 90 78 76 90 74 87 87 87 75 73 72 85 70 81 73 66 61 56 52 48 45 42 68 57 49 43 38 34 30 27 25 63 52 44 37 32 28 25 23 20 71 62 54 49 44 40 36 33 31 66 56 48 42 37 33 30 27 25 68 59 52 47 42 38 35 32 30 60 50 42 36 32 28 25 22 20 65 57 51 45 41 37 34 31 29 57 47 40 34 30 26 23 21 19 74 64 57 50 45 41 37 34 32 62 51 43 37 32 28 25 22 20 64 54 47 41 36 32 29 26 24 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle In Deg 45 55 65 75 85 Lumens %Lamp %Fixture 1279 2127 3942 5266 5266 20.6 34.3 63.6 84.9 84.9 24.3 40.4 74.9 100.0 100.0 Average 0-Deg cd/sm 2186 2115 1996 1743 1331 Illuminance Estimator 62 53 46 40 36 32 29 26 24 Average 45-Deg cd/sm 2425 2513 2651 2524 1939 59 49 42 36 31 28 25 22 20 Average 90-Deg cd/sm 2628 2830 2902 2574 1857 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 45° Across⊥ 1613 1605 1585 1550 1501 1439 1365 1279 1183 1079 966 1613 1610 1594 1568 1530 1482 1424 1357 1281 1197 1106 1613 1616 1604 1585 1557 1520 1476 1424 1365 1297 1220 847 722 589 452 315 187 81 0 1006 898 782 634 456 280 118 0 1133 1021 856 663 465 277 113 0 Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD) Based on 100 ft. x 100 ft. Open Room Ballast Factor 0.77 0.88 1.0 1.15 FC LPD FC LPD FC LPD FC LPD 8' x 10' 44 0.58 51 0.64 57 0.74 66 0.88 10' x 10' 37 0.48 42 0.53 48 0.62 55 0.73 10' x 12' 30 0.38 34 0.42 39 0.50 45 0.58 Choose the spacing and ballast factor to determine the average footcandle and watts per square foot values. All calculations are based on the published IESNA Zonal Cavity Method and associated algorithms. Results are calculated from the content of the manufacturer’s photometric files. Fixture Spacing 2AC-232 Ordering Information SAMPLE NUMBER: 2AC-232-UNV-HB81-U Rating Blank= Standard NY=New York Rated ATW-SW4= Chicago Rated Width 2=2' Width Series AC=Accord Series (1) Type A=Air (optional) Number of Lamps (Not included) 2=2 Lamp Wattage (Length) 28T8=28W T8 (48") (3) 32=32W T8 (48") Shielding Blank=Frosted Acrylic SQP=Lens with Square Pattern Insert RDP=Lens with Round Pattern Insert Voltage (1) UNV=Universal Voltage 120-277 Lamps (2) L8835=T8 Lamp, 28W and 32W, 3500K (3) L8841=T8 Lamp, 28W and 32W, 4100K (3) L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens Options GL=Single Element Fuse GM=Double Element Fuse Flex=Flex installed EL=Emergency Installed (2) Packaging Ballast Type (1) U=Unit Pack HPT8 Ballast PALC=Job Pack, HB8 L=T8 Electronic Instant Start. in carton Low Ballast Factor .71–.77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .71–.77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 (3) NOTES: Products also available in non-US voltages and frequencies for international markets. Standard ballast configurations also available. Other lamp options available. When utilizing 28W T8 lamps, HPT8 Ballast must be specified. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. 12 Accord 2' x 2' Photometrics Coefficients of Utilization 2AC-217 Electronic Ballast (2) F17T8/TL841 lamps 1400 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency 84.3% Test Report: 2AC-217.IES LER = FL-69 LPW Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.47 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 100 91 83 75 69 63 58 54 50 46 44 94 82 71 62 55 49 44 40 36 33 31 90 78 68 60 53 47 43 39 35 32 30 86 75 66 57 51 46 41 37 34 32 29 84 70 58 48 41 35 30 26 23 21 19 100 87 76 66 58 52 46 42 38 35 32 100 84 70 59 50 44 38 34 31 28 25 100 80 65 53 45 38 33 29 26 23 21 98 89 80 73 67 61 56 52 48 45 42 98 85 74 65 57 51 46 41 38 34 32 98 82 68 58 50 43 38 34 30 28 25 98 79 64 53 44 38 33 29 26 23 21 94 79 66 56 49 42 37 33 30 27 25 94 76 62 52 44 37 33 29 25 23 21 90 76 64 55 47 41 37 33 30 27 24 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle In Deg 45 55 65 75 85 Lumens %Lamp %Fixture 588 979 1813 2360 2360 21.0 35.0 64.7 84.3 84.3 24.9 41.5 76.8 100.0 100.0 Average 0-Deg cd/sm 1830 1735 1595 1355 998 90 74 61 51 43 37 32 28 25 23 21 86 73 62 53 46 41 36 32 29 26 24 Average 45-Deg cd/sm 2134 2190 2245 1901 1060 86 72 59 50 42 37 32 28 25 23 21 Average 90-Deg cd/sm 2357 2526 2444 1775 1029 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 45° Across⊥ 737 735 724 707 682 652 616 574 527 476 422 737 735 729 719 703 683 658 628 594 555 511 737 737 735 729 720 707 690 669 643 613 576 366 308 248 188 129 76 32 0 462 408 349 274 181 99 34 0 533 475 380 266 169 92 33 0 Ordering Information SAMPLE NUMBER: 2AC-217-UNV-HB81-U Rating Blank= Standard NY=New York Rated ATW-SW4= Chicago Rated Width 2=2' Width Series AC=Accord Series (1) Type A=Air (optional) Number of Lamps (Not included) 2=2 Lamp Wattage (Length) 17=17W T8 (24") Shielding Blank=Frosted Acrylic SQP=Lens with Square Pattern Insert RDP=Lens with Round Pattern Insert Lamps (2) L8835=T8 Lamp, 17W, 3500K L8841=T8 Lamp, 17W, 4100K Voltage (1) UNV=Universal Voltage 120-277 Options GL=Single Element Fuse GM=Double Element Fuse Flex=Flex installed EL=Emergency Installed Packaging Ballast Type (1) U=Unit Pack HPT8 Ballast PALC=Job Pack, HB8 L=T8 Electronic Instant Start. in carton Low Ballast Factor .71–.77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .71–.77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 (2) NOTES: Products also available in non-US voltages and frequencies for international markets. Standard ballast configurations also available. Other lamp options available. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. 13 Cooper Lighting, LLC. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 International Sales, USA Cooper Lighting, LLC. 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 F: 770-486-4801 P: 770-486-4800 F: 770-486-4801 www.cooperlighting.com Canada Cooper Lighting, LLC. 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P: 905-507-4000 F: 905-568-7049 Domestic Facilities Cranbury, New Jersey Elk Grove Village, Illinois Irving, Texas Ontario, California Peachtree City, Georgia Canadian Facility Calgary, Alberta T2E 7V9 Mississauga, Ontario L5R 1B8 Cooper Lighting and Metalux are valuable trademarks of Cooper Industries in the United States and other countries. You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries. Cooper Industries plc 600 Travis, Ste. 5600 Houston, TX 77002-1001 P: 713-209-8400 www.cooperindustries.com ADF092089 Printed in USA The Cooper Lighting Family Halo Metalux Lumark Sure-Lites Neo-Ray Corelite Portfolio Iris Shaper io Lumière Invue McGraw-Edison Streetworks Fail-Safe PDS MWS RSA Ametrix