Disconnects - Air Conditioning Application •NEMA® 3R outdoor enclosures offered in metallic and nonmetallic versions •Horsepowerrated(10hpmaximumat240Vac) •Surfaceorflushmount(seechart) Construction •Easy-to-removehighstrengthprotectiveshieldforeasierwiring and mounting • Easy-to-removefrontcover(noscrewsorfastenerstoremove) • Amplewiringspaceformountingwithastudgun(simple keyhole,twoorthree-pointmounting) • Fuseddevicesareserviceentrancerated • Padlockabledoorprovisionforsafetyandreductionoftampering • Metallicenclosuresarebottomentryandexitonly • Metallicenclosureshaveknockoutsandahubprovisionfortop access • Nonmetallicenclosureshaveasingleunitdoorandprotective shield for installer convenience • Nonmetallicenclosuresaredurableandprovideexcellent resistance to climate changes AC60NOMT0 (shown open & closed) Standards •ULlistedfileNo.E5239 •SeparateCSA® approved unit AC30FPNM0 (shown open & closed) Part/UPC Number Power Specification •10,000amperesrmssymmetricalinterruptingrating •Horsepowerrated •Fusibleandnon-fusiblepulloutandmoldedcaseswitchdesigns •30and60amperesavailableinfusible •60amperesavailableinnon-fusibleandmoldedswitchcase •ClassHfuseclipsprovidedonfusiblepulloutdesign Catalog Number Maximum HP AC Disconnect Wire Range CU AL Neutral Conductor CU / AL Wire Rating Line Load CU °C AL °C Overall Dimensions Height Width Depth Figure Number AC60NOMT0 AC60NONM0 10 10 #14 - #2 #14 - #2 #12 - #6 #12 - #6 #14 - #4 #14 - #4 60°/75° 60°/75° 60°/75° 60°/75° 8 3/4” 8 11/16” 5 3/8” 6 1/4” 3 1/8” 3 3/8” Fig. 1 Fig. 2 AC30FPMT0 AC30FPNM0 10 10 #14 - #2 #14 - #2 #12 - #6 #12 - #6 #14 - #4 #14 - #4 60°/75° 60°/75° 60°/75° 60°/75° 8 3/4” 5 3/8” 8 11/16” 6 1/4” 3 1/8” 3 3/8” Fig. 1 Fig. 2 AC60FPMT0 AC60FPNM0 10 10 #14 - #2 #14 - #2 #12 - #6 #12 - #6 #14 - #4 #14 - #4 60°/75° 60°/75° 60°/75° 60°/75° 8 3/4” 5 3/8” 8 11/16” 6 1/4” 31/8” 3 3/8” Fig. 1 Fig. 2 #14 - #2 #12 - #6 #14 - #4 60°/75° 60°/75° 4 3/4” Fig. 3 60 Amp - Nonfusible 78205139801 78205141681 30 Amp - Fused 78205141677 78205141679 60 Amp - Fused 78205141687 78205141680 60 Amp - Nonfusible with GFCI Duplex Receptacle 78205139802 AC60NOMT2 10 13” 7 1/2” Fused non-metallic units require the addition of GB5NM ground bar Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches. 39 Meter Mounting - Midwest & Texas Utilities Disconnects - Air Conditioning Knockouts - Conduit Sizes 1X = 9⁄32” 2B = 3⁄4” - 1⁄2” 2C = 1” - 3⁄4” 3C = 1” - 3⁄4” - 1⁄2” 3D = 11⁄4” - 1” - 3⁄4” 4E = 11⁄2” - 11⁄4” - 1” - 3⁄4” Knockout Layouts Fig. 1 2B Fig. 2 3D 3C 2B 2C 2B 2B 3C 1X Fig. 3 4E 3C 2B 2B Datasubjecttochangewithoutnotice.Consultlocalutilityforareaacceptance.Alldimensionsareininches. Meter Mounting - Midwest & Texas Utilities 40 2C