Series 2, 3, 4, & 5 Aluminum - Straight Sections 5" NEMA VE 1 Loading Depth 6" Side Rail Height Straight Section Part Numbering Prefix Example: 26 A 09 - 24 - 144 Series Material *Type A = Aluminum 26 *Width Ladder06 = 6" rung spacing 09 = 9" rung spacing 12 = 12" rung spacing 36 46 Trough6" thru 36" wide VT = Vented Trough ST = Non-Ventilated Trough H46† Overall Width (Width + 11/2") = = = = = = = 6" 9" 12" 18" 24" 30" 36" ¨ ¡ ¨ ¡ ¨ ¡ ¨ ¡ Length 144 240 240 144 240 288 240 300 = = = = = = = = ¨Primary Rung Spacing Width (Inside) 06 09 12 18 24 30 36 † H46A only available in ladder type 9” and 12” rung spacing For side rail & rung data, see chart on pages AP-5 & AP-6 See page APP-2. 12 20 20 12 20 24 20 25 ft. 26 ft. ft. 36 ft. ft. 46 ft. ft. H46 ft. Length. Length. ¡Secondary See page CTS-23 for explanation of lengths. Series 2, 3, 4, & 5 Aluminum See page APP-1 for additional rung options. *Special sizes available. Ladder Type Ventilated Trough Non-Ventilated Trough (Specify Rung Spacing) Green = Fastest shipped items Black = Normal lead-time items HAT-7 Red = Normally long lead-time items Cable Tray Systems Series 2, 3, 4, & 5 Aluminum - Straight Sections 5" NEMA VE 1 Loading Depth 6" Side Rail Height Values are based on simple beam tests per NEMA VE 1 on 36" wide cable tray with rungs spaced on 12" centers. Cable trays will support, without collapse, a 200 lb. (90.7 kg) concentrated load over and above published loads. Published load safety factor is 1.5. To convert 1.5 safety factor to 2.0, multiply the published load by 0.75. To obtain mid-span deflection, multiply a load by the deflection multiplier. Cable tray must be supported on spans shorter than or equal to the length of the cable tray being installed. Individual rungs will support without collapse a 200 lb. (90.7 kg) concentrated load applied at the mid-span of the rung, over and above the NEMA rated cable load with a 1.5 safety factor for highlighted NEMA spans and loads. B-Line Series 26 Side Rail Dimensions NEMA, CSA & UL Classifications Span ft Load lbs/ft Deflection Multiplier 2.00 NEMA: 20A, 16B CSA: 67 kg/m 6.0m D-6m UL Cross-Sectional Area: 1.00 in2 10 12 14 16 18 20 204 142 104 80 63 51 0.0028 0.006 0.011 0.019 0.030 0.045 5.04 6.12 Design Factors Span for Two Rails meters Area=1.41 in2 Sx=2.53 in3 Ix=7.915 in4 3.0 3.7 4.3 4.9 5.5 6.1 Load kg/m Deflection Multiplier 304 211 155 119 94 76 0.049 0.101 0.186 0.318 0.509 0.776 Design Factors for Two Rails Area=9.10 cm2 Sx=41.46 cm3 Ix=329.45 cm4 When trays are used in continuous spans, the deflection of the tray is reduced by as much as 50%. Design factors: Ix = Moment of Inertia, Sx = Section Modulus. B-Line Series Side Rail Dimensions 2.00 36 5.06 6.17 NEMA, CSA & UL Classifications Span ft Load lbs/ft Deflection Multiplier NEMA: 20B, 16C CSA: 112 kg/m 6.0m E-6m UL Cross-Sectional Area: 1.50 in2 12 14 16 18 20 22 233 171 131 104 84 69 0.0043 0.008 0.014 0.022 0.033 0.049 Design Factors Span for Two Rails meters Area=1.81 in2 Sx=3.36 in3 Ix=10.85 in4 3.7 4.3 4.9 5.5 6.1 6.7 Load kg/m Deflection Multiplier 347 255 195 154 125 103 0.073 0.136 0.232 0.372 0.566 0.829 Design Factors for Two Rails Area=11.68 cm2 Sx=55.06 cm3 Ix=451.61 cm4 When trays are used in continuous spans, the deflection of the tray is reduced by as much as 50%. Design factors: Ix = Moment of Inertia, Sx = Section Modulus. Side Rail Dimensions 2.00 46 5.08 6.19 NEMA, CSA & UL Classifications Span ft Load lbs/ft Deflection Multiplier NEMA: 20C CSA: 168 kg/m 6.1m E-6m UL Cross-Sectional Area: 1.50 in2 14 16 18 20 22 24 210 161 127 103 85 72 0.0071 0.012 0.019 0.030 0.043 0.061 Design Factors Span for Two Rails meters Area=2.06 in2 Sx=3.59 in3 Ix=12.18 in4 4.3 4.9 5.5 6.1 6.7 7.3 Load kg/m Deflection Multiplier 313 239 189 153 127 106 0.121 0.207 0.331 0.505 0.739 1.046 Design Factors for Two Rails Area=13.29 cm2 Sx=58.83 cm3 Ix=506.97 cm4 When trays are used in continuous spans, the deflection of the tray is reduced by as much as 50%. Design factors: Ix = Moment of Inertia, Sx = Section Modulus. B-Line Series Side Rail Dimensions NEMA, CSA & UL Classifications Span ft Load lbs/ft Deflection Multiplier 2.00 NEMA: 20C+ CSA: 131 kg/m 7.6m E-6m UL Cross-Sectional Area: 2.00 in2 16 18 20 22 24 25 261 206 167 138 116 88 0.0085 0.014 0.021 0.030 0.043 0.051 H46 6.24 5.09 Design Factors Span for Two Rails meters Area=2.95 in2 Sx=5.33 in3 Ix=17.30 in4 4.9 5.5 6.1 6.7 7.3 7.6 Load kg/m Deflection Multiplier 388 307 248 205 173 131 0.145 0.233 0.355 0.520 0.737 0.867 Design Factors for Two Rails Area=19.03 cm2 Sx=87.34 cm3 Ix=720.08 cm4 When trays are used in continuous spans, the deflection of the tray is reduced by as much as 50%. Design factors: Ix = Moment of Inertia, Sx = Section Modulus. Cable Tray Systems HAT-8 Series 2, 3, 4, & 5 Aluminum B-Line Series