3.051J/20.340J Problem Set 1

advertisement
1
3.051J/20.340J Problem Set 1
due 2/16/06
1. (12 pts) Bone tissue engineering generally involves the implantation of a synthetic or
biologically derived material that upon implantation allows for bone in-growth and
eventual replacement. In a recent publication, De Groot and coworkers (Tissue Eng.
2003, 9, 535) compared the structures of 3 commercially produced biphasic calcium
phosphate (BCP) porous scaffolds for bone tissue engineering. BCP is a two phase
material of hydroxyapatite and tricalcium phosphate. SEM images below illustrate crosssections of the scaffolds manufactured by Zimmer (left image), Dytech (middle image)
and IsoTis (right image). Scale bar is 1 mm.
Image removed for copyright reasons.
See Fig. 3, top images, in Li, Shihong, Joost de Wijn, Jiaping Li, Pierre Layrolle, and
Klaas de Groot. "Macroporous Biphasic Calcium Phosphate Scaffold with High
Permeability/Porosity Ratio." Tissue Eng 9 (2003): 535-548.
a) What aspects of the primary chemical structure, higher order (meso) structure and/or
microstructure make these scaffolds useful for bone tissue engineering?
b) Download the article by De Groot and coworkers through the MIT library. What
processing approaches resulted in the dramatically different pore morphologies observed
in the SEM images for the 3 BCP scaffolds?
c) A table of the scaffold porosities and specific permeabilities measured by De Groot
and coworkers is provided below. Explain why the IsoTis scaffold, with the lowest
porosity, exhibits the highest permeability.
Manufacturer
Specific permeability (m2)
Porosity (%)
Zimmer
0.02 × 10-9
75
Dytech
0.12 × 10-9
80
IsoTis
0.34 × 10-9
60
3.051J/20.340J Problem Set 1
2
due 2/16/06
2) (16 pts) Recently, Yokoyama and coworkers described the preparation of proteinresistant surfaces on polystyrene (PS) through the addition of 10% of a block copolymer
additive (PS-b-PME3MA) whose structure is shown below (A. Oyane et al., Adv. Mater.
2005, 17, 2329; H. Yokoyama et al., Macromol. 2005, 38, 5180). Contact angle
measurements performed on annealed blends with different block copolymer contents are
also shown.
a) Explain why the advancing contact angle first decreases then plateaus as the block
copolymer content in the blend is increased.
b) What possible energetic driving forces might lead to the phenomenon in (a)?
c) Based on the contact angle data, approximate the composition of the surface for 10
wt% bulk concentration of PS-b-PME3MA.
d) For blend systems with >20% block copolymer, what is the molecular origin of the
large hysteresis in the contact angle (i.e., the much lower receding contact angle value
compared with the advancing angle)?
e) How might the contact angle results change if the terminal group of the methacrylate
side chain were changed to a hydroxyl (-OH)?
Image removed for copyright reasons.
Please see Scheme 1 and Fig. 9 in Yokoyama, H., T. Miyamae, S. Han, T. Ishizone,
K. Tanaka, A. Takahara, and N. Torikai. " Spontaneously Formed Hydrophilic Surfaces
by Segregation of Block Copolymers with Water-Soluble Blocks." Macromolecules 38
(2005): 5180-5189.
3) (12 pts) Chen et al. investigated adhesion of endothelial cells on titanium oxide
coatings as a possible surface treatment to reduce thrombogenesis on arterial stents.
(Surface & Coatings Tech. 2004, 186, 270). X-ray diffraction measurements revealed the
as-prepared coatings to be amorphous, while coatings heat-treated for 0.5 hours at 700 °C
were crystalline. Contact angle measurements were made utilizing different liquids to
3
3.051J/20.340J Problem Set 1
due 2/16/06
determine values for the polar and disperse components of the surface energy, as listed in
the table below.
a) Can the work of cohesion for titanium dioxide be estimated from the measurements of
Chen et al.? Explain.
b) What chemical groups might you expect to observe on the TiO2 surface?
c) Why is the measured surface energy of the titanium oxide coating lower after heat
treatment?
d) Based on the surface energies provided, calculate the work of adhesion between the
surface and water for the amorphous and crystalline coatings? How might this influence
protein adsorption?
material
γp (dyn/cm)
γd (dyn/cm)
γ (dyn/cm)
amorphous
titanium oxide
30
29
59
crystalline
titanium oxide
14
26
40
water
51
22
73