KUBE Electronics AG

advertisement
KUBE Electronics AG
Industriestr. 55
8625 Gossau
Switzerland
Tel +41-43-9280550
Fax +41-43-9280551
www.kube.ch
PIR Detector Module
TR257-1 (opaque lens)
TR257-2 (black lens)
Small PIR module with digital output,
including golfball lens. For use in
control applications, alarms, lighting,
motion detection.
Properties
Pattern
+- 50° / +-30°
Zones
5 Meters
17
Supply
4.75 …. 10 VDC , 2 mA max
Output
NPN Open Collector, active low, 15VDC max,
will sink at least 1mA
Stabilizing Time
30 sec max after Power On
Dimensions
35 x 30 x 21 mm
Temperature Range
LxWxH
-20 …. + 50 °C
Detailed specification available on separate datasheet.
Bottom view of the module showing
the three soldering pads located
on the right edge.
Connection:
Feb 09
Vcc (top)
Out (mid)
Gnd (low)
1/1
Industriestr. 55
8625 Gossau
Switzerland
KUBE Electronics AG
TR257
Tel +41-43-9280550
Fax +41-43-9280551
www.kube.ch
PIR Detector Module
Detector module including lens, sensor and electronics, with digital output.
Applications:
Industrial control, Lighting switches, People detection and Intruder Alarms
1. DIMENSIONS & DETECTION ZONES
See Fig. 1, 2
2. MODULE STRUCTURE
Passive infrared sensor, Fresnel lens and electronic components mounted on a PC board.
3. OUTPUT
NPN Transistor (Open Collector, active low)
4. GENERAL DESCRIPTION
This module can detect infrared rays emanating from a moving human body in a specific area.
5. ELECTRICAL CHARACTERISTICS
5-1 SENSITIVITY
This module is designed to detect a human body or similar heat sources under these conditions :
Item
Installation height of module
Heat source temperature difference
Moving speed of heat source
Direction of movement
Notes
1
3 to 5
Unit
m
deg C
1.0
90
m / Sec.
degrees
from background
5-2 MAXIMUM RATINGS
Item
Breakdown voltage
Symbol
Min.
Typ.
Max.
Unit
15
VDC
Operating Temp.
TOPR
-20
-
50
deg C
Storage Temp.
TSTG
-30
-
70
deg C
Feb 09
1 (4)
at central detection zones
5-3 ELECTRICAL CHARACTERISTICS
(at 25 deg C, Vcc=5.0V if not specified otherwise)
Items.
Symbols
Min.
Typ.
Max.
Unit
Operating Voltage
VCC
4.75
5
10
VDC
Supply Current
ICC
-
1
2
mA
Stabilizing time of module
TON
-
15
30
Sec.
After power supply turn-on, the output is locked in the active state during TON.
6. CAUTIONS
1. This module detects a change of infrared energy. This module does not only detect a
moving human body but also other heat sources similar to human temperature.
2. This module cannot detect the presence of a human body if it does not move.
3. This module detects changes of infrared rays through the Fresnel lens.
Detection areas and range depend on its surface condition.
4. To prevent malfunctions, operational failure or any deterioration of its characteristics, do not use this
module in the following, or similar, conditions :
rapid ambient temperature changes
strong shock or vibration
high humidity and temperature
Unit troubles resulting from misuse, inappropriate handling or storage are not the manufacturer’s
responsibility.
Feb 09
2 (4)
TOP VIEW
(14)
30 +/-0.2
23 +/-0.1
4- Dia 3.2 +/-0.1
4C2
28 +/-0.1
35 +/-0.2
C2: Chamfer 2mm / 2mm
2
R1
0
+/-
.2
5.2 +/-0.2
max 3
1.6 +/-0.2
SIDE VIEW
1
BOTTOM VIEW
1
1 Vcc
2 OUT
3 Gnd
unit [mm]
Fig.1
Feb 09
3 (4)
DETECTION AREA
(m)
2
C
50°
F1,F2
40°
E1,E2
30°
B
20°
1
D1,D2
10°
A
0
D1',D2'
-10°
1
C'
-50°
2
1
B'
-20°
E1',E2'
-30°
F1',F2'
-40°
2
3
4
5
(m)
Horizontal
(m)
4
F1,F1'
30°
3
20°
D1,D1'
E1,E1'
A
B,B'
C,C'
2
E2,E2'
D2,D2'
1
F2,F2'
-30°
-20°
0
1
2
3
4
Vertical
Fig.2
Feb 09
4 (4)
5
(m)
Download