Building Consistency Meeting Residential Date 03/07/2012 Recorder and minutes prepared by: Danny Wooten/Lon McSwain Staff present: On File Public present: There were 34 residential contractors present at the meeting a full list is on file with this office. Old Business 4X4 deck guardrail and handrail posts A reminder that 4X4 posts cannot be notched to be attached to the deck band as guardrail supports, 6x6 post are allowed. This comes from a ruling from DOI last year that a notched 4x4 would not be capable of supporting the required live load on a guardrail system. New Business Appendix M The change to the Deck code appendix M allows stairs and roof loads to be attached to cantilevered joists in compliance with chapter 5 for cantilevers however no stair or roof load is allowed on a cantilevered area which is a limited option. Superior Wall System Superior Wall System (precast concrete foundation wall system) does not have to be damp proofed or waterproofed when a Soil Engineer provides a letter about soil conditions that identifies the specific site as not having a high water table or other moisture issues as listed in R406.2 and no dampproofing when they follow their ICC report. Both the engineer’s letter and the ICC ER report needs to be furnished to the inspector at foundation inspection. Windows were the bottom of the opening is located 24” or less AFF and 72” or more above outside grade must be equipped with a latch that will restrict the opening to resist the passage of a 4” sphere or an approved guard protection. Requirements for retaining walls have been moved but remain the same as in the 2009 code. Location may be an issue since they moved several pages back to section R404.4. New- 2012 Code item R612.2 New location2012 Code Retaining walls New- 2012 Code item Attic Storage New- 2012 Code item Live/Work Units Changes2012 Code Live Load Tables New- 2012 Code items Section R302 Attics that have only a walkway to mechanical equipment and are not specifically designed to carry attic loads must be permanently marked at the access opening (NOT FOR STORAGE). This can be found in the definition section under ATTIC STORAGE. This is an exception found in Section R101.2 referring you to the Building Code Section 419.5 for the construction of Live/Work Units. These are typically townhouse style units and there are limitations in the building code and units would have to have a sprinkler system as well. Now have habitable attics listed for 30#/sq.ft. and decks and balconies @ 40#/sq.ft. This information is listed in Table R301.5 Section R302 fire resistant construction has been rewritten. There is an exception to the required wall protection for accessory structures on the same lot however if closer than 3’ have to have ½” sheetrock on garage side. Change- 2012 Code item Fire Stopping R302.11 #4, R302.11.1.3 Change- 2012 Code item Exterior Egress Door R311.2 Change- 2012 Code item Site Address R319 New- 2012 Code item Section R323 Change- 2012 Code item Handrails R311.7.7.1 Fiberglass loose fill insulation is no longer acceptable to use as fire stopping unless specifically tested for that application. The material does not have to meet ASTM 136 but must be an approved product for that application. Code doesn’t reference what is approved however any fire caulk or fire foam would be allowed. One exterior door must have a 32” X 78” clear opening. This is a change from the previous version that indicated 3-0x6-8 and has gone to a specific net clear dimension required for that opening. This door still has to be side hinged with special locking conditions and can be anywhere in the home except through a garage. Section requires that an address be posted on site for any required residential permit and gives specific information like size to be 4” and if an address is needed at the street. New section on the requirements for storm shelters and safe rooms. Handrails must now be mounted between 34” and 38” for stairs and ramps this includes all stairs like interior stairways or exterior decks. This is a significant change to the NC market since typically for more than 20 years it has been 30”-38”. Word is going out to make sure that this information gets to the field to stair companies and deck builders. Approved By ___Lon McSwain_________ Date _____03/29/2012__