Building Consistency Meeting Residential Date 04/04/2012 Recorder and minutes prepared by: Danny Wooten/Lon McSwain/Jeff Griffin Staff present: On File Public present: Daniel McBride (Cunnare Group) ; David Reynolds (BFS) ; Matthew Klapheke (L&M Costruction) ;Jennifer Smith, ( Pultegroup) ; Kelly Strickland (The Colville Co.);Charlie Sofinowski, Ryan Meeuwsen (M/I Homes);Jerry Anderson, (Ryan Homes); Wayne Carter ( W B Carter Contracting); Alan McGee, Doc McGee (McGee Brothers) ; Brian Hall (Classic Homes); Mark ( Gorilla Construction); Banks Pickens (Shea Homes); Jeff Gerdes (Live Well); John Tammao (Simonini); Marcel Papingau, Damon Howard (Howard Verna Engineering) Old Business None New Business Weep Holes Note in section R703.7 spacing of weep holes has changed from 48” to 33” oc. Safety Glazing R308.4 Glazing adjacent to a stairway or landing within 36” horizontally of a walking surface when the glazing is less than 60” above the walking surface or glazing adjacent to stairways within 60” horizontally of the bottom tread of a stairway in any direction and is less than 60” above the nose of the tread is required to be safety glazing. This is a new requirement and will require tempered on side walls of stairways and closer around landings. Illustration below shows shaded area that is considered a hazardous location: 60” High Efficiency Bulbs In new construction75% of the light fixtures must be supplied with high efficiency light bulbs for final inspection. Mechanical Requirements See the 2012 residential section of the Mechanical Code for new requirements for kitchen hoods and ventilation of habitable spaces, must vent to exterior and have a damper. Section R303.1 Exception 2 Foundation Straps Handrails When a habitable room has no exterior source of light and no installed light fixture the contractor must provide information on how the minimum required lighting level is to be supplied. Installation of straps to tie the sill plate to the foundation must be installed per the requirements of the manufacturer. The height of handrails has changed it is now 34” to 38”. Fireplace Inspections Building inspectors will inspect all wood burning fireplaces this includes inserts and their flues, only gas fireplaces will be inspected by Mechanical inspectors. Approved By ___Lon McSwain_________ Date _____04/27/2012__