1 A 2 3 4 5 6 7 8 9 MASONRY AND FLASHING REPAIRS AT: HUNTLEY HIGH SCHOOL, HEINEMAN MIDDLE SCHOOL, AND MARLOWE MIDDLE SCHOOL HUNTLEY COMMUNITY SCHOOL DISTRICT #158 10 MASONRY AND FLASHING REPAIRS AT: HUNTLEY 123 Elm St. Anytown, USA 12345 HIGH SCHOOL, HEINEMAN MIDDLE SCHOOL, AND MARLOWE MIDDLE SCHOOL HUNTLEY COMMUNITY SCHOOL DISTRICT #158 650 Academic Drive Algonquin, IL 60102 Algonquin, IL IL B C D E ARCHITECTURAL Central: L:\SD_Huntley\163025_Masonry and Flashing Repairs\163025_masonry and flashing drawings (central).rvt 4/14/2016 9:58:36 AM C:\Users\kgray\Documents\163025_masonry and flashing drawings (central)_kgray.rvt F A1.51 A1.52 A1.53 A2.01 A2.02 A2.03 A2.04 A3.01 HUNTLEY HIGH SCHOOL ROOF PLAN HEINEMAN MIDDLE SCHOOL ROOF PLAN MARLOWE MIDDLE SCHOOL ROOF PLAN HEINEMAN MIDDLE SCHOOL- EXTERIOR ELEVATIONS HEINEMAN MIDDLE SCHOOL- EXTERIOR ELEVATIONS MARLOWE MIDDLE SCHOOL- EXTERIOR ELEVATIONS MARLOWE MIDDLE SCHOOL- EXTERIOR ELEVATIONS TYPICAL DETAILS G H Set No: Comm No: 163025 1 2 3 4 5 6 7 8 MASONRY AND FLASHING REPAIRS AT: HUNTLEY 123 Elm St. Anytown, USA 12345 HIGH SCHOOL, HEINEMAN MIDDLE SCHOOL, AND MARLOWE MIDDLE SCHOOL A HUNTLEY COMMUNITY SCHOOL DISTRICT #158 650 Academic Drive Algonquin, IL 60102 (ROOF A) IL B 31031 31027 31030 (ROOF D) (ROOF K) (ROOF C) (ROOF E) 31029 31024 (ROOF J) 31010 31010 31028 31025 SIM 31009 31011 (ROOF XI) 31011 SIM C 31021 31021 31023 (ROOF II) SIM (ROOF X) 31014 (ROOF AA) 31020 31022 31018 31013 31006 31019 31001 31026 (ROOF HH) (ROOF DD) 31008 31007 (ROOF CC) 31005 (ROOF JJ) 31003 31016 (ROOF BB) D 31017 31015 31002 Central: L:\SD_Huntley\163025_Masonry and Flashing Repairs\163025_masonry and flashing drawings (central).rvt 4/14/2016 9:58:36 AM C:\Users\kgray\Documents\163025_masonry and flashing drawings (central)_kgray.rvt GENERAL NOTES: 120V POWER AVAILABLE AT MULTIPLE POINTS ON ROOF. CONTRACTOR TO PROVIDE POWER CORDS AS REQUIRED. 2. POTABLE WATER IS AVAILABLE AT MULTIPLE POINTS. CONTRACTOR TO PROVIDE HOSES AS REQUIRED. 3. MASONRY VENEER UNITS TO BE REMOVED/REPLACED ARE TYPICALLY SPLIT-FACE CONCRETE BLOCK, AND MULTIPLE COLORS EXIST. MATCH COLORS USING SPLIT-FACE CONCRETE BLOCK UNITS SPECIFIED. FIELD VERIFY QUANTITIES OF EACH COLOR REQUIRED. I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed ARCHITECT IL under the laws of the State of E Registration Number TEDD STROMSWOLD 001-020603 Date 4/8/2016 Revisions Description Date Num HIGH SCHOOL ROOF LEGEND F1 A 1. DENOTES EXISTING ROOF AREAS TO BE RE-ROOFED DURING SUMMER 2016 UNDER SEPARATE CONTRACT. HUNTLEY HIGH SCHOOL ROOF PLAN 1" = 30'-0" 0 22'-6" DENOTES THROUGH WALL FLASHING REPAIR WORK TO BE INCLUDED IN BASE BID. SEE TYPICAL DETAILS C1/A3.01 & D4/A3.01 45' DENOTES THROUGH WALL FLASHING REPAIR WORK TO BE INCLUDED IN ALTERNATE #1. SEE TYPICAL DETAILS C1/A3.01 & D4/A3.01 F DENOTES THROUGH WALL FLASHING REPAIR WORK TO BE INCLUDED IN ALTERNATE #2. SEE TYPICAL DETAILS C1/A3.01 & D4/A3.01 XXXXX X XXXX DENOTES IMAGE INCLUDED WITHIN PROJECT MANUAL (AND WORK DESCRIBED THEREIN) DENOTES DETAIL OF CONSTRUCTION INCLUDED ON DRAWING SHEET. Comm: 163025 Date: 4/14/2016 Drawn: JRK Check: TS North HUNTLEY HIGH SCHOOL ROOF PLAN Scale: As indicated A1.51 1 2 3 4 5 6 7 8 MASONRY AND FLASHING REPAIRS AT: HUNTLEY 123 Elm St. Anytown, USA 12345 HIGH SCHOOL, HEINEMAN MIDDLE SCHOOL, AND MARLOWE MIDDLE SCHOOL A HUNTLEY COMMUNITY SCHOOL DISTRICT #158 650 Academic Drive Algonquin, IL 60102 IL 31211 B 31210 C D 31208 31207 31205 31206 31204 GENERAL NOTES: Central: L:\SD_Huntley\163025_Masonry and Flashing Repairs\163025_masonry and flashing drawings (central).rvt 4/14/2016 9:58:37 AM C:\Users\kgray\Documents\163025_masonry and flashing drawings (central)_kgray.rvt 31209 31204 31202 31201 31203 SIM (AT LINTEL ABOVE DOOR) 31203 TYPICAL OF (2) LOCATIONS 1. 120V POWER AVAILABLE AT MULTIPLE POINTS ON ROOF. CONTRACTOR TO PROVIDE POWER CORDS AS REQUIRED. 2. POTABLE WATER IS AVAILABLE AT MULTIPLE POINTS. CONTRACTOR TO PROVIDE HOSES AS REQUIRED. 3. MASONRY VENEER UNITS TO BE REMOVED/REPLACED ARE TYPICALLY UTILITY SIZE BRICK. 4. SEE ALSO EXTERIOR ELEVATION DRAWINGS FOR WORK AT EXTERIOR WALL OF THE BUILDING. TYPICAL OF (3) LOUVERS ON THIS WALL ELEVATION E ARCHITECT IL under the laws of the State of Registration Number TEDD STROMSWOLD 001-020603 Date 4/8/2016 Revisions Description MIDDLE SCHOOL ROOF LEGEND XXXXX X XXXX F3 F HEINEMAN MIDDLE SCHOOL ROOF PLAN 1" = 20'-0" 0 15' Date Num DENOTES IMAGE INCLUDED WITHIN PROJECT MANUAL (AND WORK DESCRIBED THEREIN). DENOTES DETAIL OF CONSTRUCTION INCLUDED ON DRAWING SHEET. DENOTES THROUGH WALL FLASHING REPAIR WORK TO BE INCLUDED IN BASE BID. SEE TYPICAL DETAILS C1/A3.01 & D4/A3.01 A I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Comm: 163025 Date: 4/14/2016 Drawn: JRK Check: TS North HEINEMAN MIDDLE SCHOOL ROOF PLAN 30' Scale: As indicated A1.52 1 2 3 4 5 6 7 8 MASONRY AND FLASHING REPAIRS AT: HUNTLEY 123 Elm St. Anytown, USA 12345 HIGH SCHOOL, HEINEMAN MIDDLE SCHOOL, AND MARLOWE MIDDLE SCHOOL A HUNTLEY COMMUNITY SCHOOL DISTRICT #158 650 Academic Drive Algonquin, IL 60102 IL B C 31204 TYPICAL OF (2) LOCATIONS 31203 31202 D TYPICAL OF (3) LOUVERS ON THIS WALL ELEVATION SIM (AT LINTEL ABOVE DOOR) 31203 31201 31209 C1 ______ A3.01 SIM C1 ______ A3.01 SIM Central: L:\SD_Huntley\163025_Masonry and Flashing Repairs\163025_masonry and flashing drawings (central).rvt 4/14/2016 9:58:37 AM C:\Users\kgray\Documents\163025_masonry and flashing drawings (central)_kgray.rvt GENERAL NOTES: 1. E 120V POWER AVAILABLE AT MULTIPLE POINTS ON ROOF. CONTRACTOR TO PROVIDE POWER CORDS AS REQUIRED. 2. POTABLE WATER IS AVAILABLE AT MULTIPLE POINTS. CONTRACTOR TO PROVIDE HOSES AS REQUIRED. 3. MASONRY VENEER UNITS TO BE REMOVED/REPLACED ARE TYPICALLY UTILITY SIZE BRICK. 4. SEE ALSO EXTERIOR ELEVATION DRAWINGS FOR WORK AT EXTERIOR WALL OF THE BUILDING. I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed ARCHITECT IL under the laws of the State of Registration Number TEDD STROMSWOLD 001-020603 Date 4/8/2016 Revisions MIDDLE SCHOOL ROOF LEGEND XXXXX F2 MARLOWE MIDDLE SCHOOL ROOF PLAN 1" = 20'-0" X XXXX 0 15' Description Date Num DENOTES IMAGE INCLUDED WITHIN PROJECT MANUAL (AND WORK DESCRIBED THEREIN). DENOTES DETAIL OF CONSTRUCTION INCLUDED ON DRAWING SHEET. Comm: 163025 Date: 4/14/2016 DENOTES THROUGH WALL FLASHING REPAIR WORK TO BE INCLUDED IN BASE BID. SEE TYPICAL DETAILS C1/A3.01 & D4/A3.01 Drawn: JRK Check: TS 30' North MARLOWE MIDDLE SCHOOL ROOF PLAN A F Scale: As indicated A1.53 1 2 3 4 5 6 7 8 MASONRY AND FLASHING REPAIRS AT: HUNTLEY 123 Elm St. Anytown, USA 12345 HIGH SCHOOL, HEINEMAN MIDDLE SCHOOL, AND MARLOWE MIDDLE SCHOOL A NOTE: DIMENSION INDICATES LENGTH OF P.C. CONCRETE SECTION TO BE REMOVED AND REINSTALLED, TYP. F1 ______ A3.01 SIM F1 ______ A3.01 (14'-8") SIM F1 ______ A3.01 (9'-8") HUNTLEY COMMUNITY SCHOOL DISTRICT #158 SIM 650 Academic Drive Algonquin, IL 60102 (10'-4") IL B B1 EAST ELEVATION 1/16" = 1'-0" 0 B7 12' 24' ENLARGED ELEVATION, TYP. 1/8" = 1'-0" 0 6' 12' B7 ______ A2.01 F1 ______ A3.01 SIM SIM (11'-8") F1 ______ A3.01 SIM F1 ______ A3.01 (40') C D1 F1 ______ A3.01 F1 ______ A3.01 (11'-8") SIM (9'-8") F1 ______ A3.01 SIM F1 ______ A3.01 (9'-8") SIM F1 ______ A3.01 SIM F1 ______ A3.01 (9'-8") (9'-10") SIM (9'-8") F1 ______ A3.01 SIM (9'-8") F1 ______ A3.01 SIM (9'-8") F1 ______ A3.01 SIM F1 ______ A3.01 SIM (13'-6") SIM (10'-4") (9'-8") WEST ELEVATION 1/16" = 1'-0" 12' 0 24' F1 A2.01 F1 ______ A3.01 B4 A2.02 D SIM F1 ______ A3.01 SIM F1 ______ A3.01 SIM D1 A2.02 (14'-8") PENTHOUSE BEYOND B3 A2.02 (10'-4") (9'-8") B1 A2.02 E1 A2.02 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed ARCHITECT E1 1/16" = 1'-0" 0 12' 24' A4 A2.02 Registration Number A2 A2.02 F1 ______ A3.01 SIM (14'-8") F1 ______ A3.01 SIM (14'-8") F1 ______ A3.01 SIM F1 ______ A3.01 (11'-8") SIM Description A1 A2.02 A1 A2.02 D1 A2.02 12' Comm: 163025 Date: 4/14/2016 Drawn: JRK Check: TS North HEINEMAN MIDDLE SCHOOL- EXTERIOR ELEVATIONS D1 A2.02 NORTH ELEVATION 0 Num (11'-10") F 1/16" = 1'-0" Date SIM (25') F1 TEDD STROMSWOLD 001-020603 Date 4/8/2016 Revisions REV F1 ______ A3.01 A IL under the laws of the State of SOUTH ELEVATION B1 A2.01 E D1 A2.01 Central: L:\SD_Huntley\163025_Masonry and Flashing Repairs\163025_masonry and flashing drawings (central).rvt 4/14/2016 9:58:37 AM C:\Users\kgray\Documents\163025_masonry and flashing drawings (central)_kgray.rvt A6 A2.02 24' Scale: E1 A2.01 ELEVATION KEYPLAN As indicated A2.01 1 2 F1 ______ A3.01 SIM F1 ______ A3.01 (6'-1") 3 4 SIM F1 ______ A3.01 (6'-1") 5 SIM F1 ______ A3.01 6 7 8 F1 ______ A3.01 SIM (10'-5") (11'-1") (10'-5") SIM NOTE: DIMENSION INDICATES LENGTH OF P.C. CONCRETE SECTION TO BE REMOVED AND REINSTALLED, TYP. A MASONRY AND FLASHING REPAIRS AT: HUNTLEY 123 Elm St. Anytown, USA 12345 HIGH SCHOOL, HEINEMAN MIDDLE SCHOOL, AND MARLOWE MIDDLE SCHOOL HUNTLEY COMMUNITY SCHOOL DISTRICT #158 650 Academic Drive Algonquin, IL 60102 A1 PARTIAL ELEVATION 1/16" = 1'-0" 0 12' A2 24' PARTIAL ELEVATION 1/16" = 1'-0" 0 12' A4 24' PARTIAL ELEVATION 1/16" = 1'-0" 0 12' A6 24' PARTIAL ELEVATION 1/16" = 1'-0" 0 12' 24' IL F1 ______ A3.01 F1 ______ A3.01 SIM F1 ______ A3.01 SIM SIM (11'-9") (10'-5") (10'-5") B B1 PARTIAL ELEVATION 1/16" = 1'-0" 0 12' B3 24' PARTIAL ELEVATION 1/16" = 1'-0" 0 12' B4 24' PARTIAL ELEVATION 1/16" = 1'-0" 0 12' 24' F1 ______ A3.01 C SIM (14'-6") D1 PARTIAL ELEVATION 1/16" = 1'-0" 0 12' 24' F1 A2.01 D SIM B4 A2.02 F1 ______ A3.01 D1 A2.02 (7') B3 A2.02 PARTIAL ELEVATION 1/16" = 1'-0" 0 12' E1 A2.02 A6 A2.02 24' I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed ARCHITECT B1 A2.01 A4 A2.02 Registration Number A2 A2.02 Revisions Description REV A1 A2.02 D1 A2.02 A1 A2.02 TEDD STROMSWOLD 001-020603 Date 4/8/2016 F Comm: 163025 Date: 4/14/2016 Drawn: Author Check: Checker Date HEINEMAN MIDDLE SCHOOL- EXTERIOR ELEVATIONS Scale: E1 A2.01 ELEVATION KEYPLAN Num North D1 A2.02 A IL under the laws of the State of E D1 A2.01 Central: L:\SD_Huntley\163025_Masonry and Flashing Repairs\163025_masonry and flashing drawings (central).rvt 4/14/2016 9:58:37 AM C:\Users\kgray\Documents\163025_masonry and flashing drawings (central)_kgray.rvt E1 B1 A2.02 As indicated A2.02 1 2 3 SIM F1 ______ A3.01 F1 ______ A3.01 4 5 SIM F1 ______ A3.01 SIM F1 ______ A3.01 (14'-10") (14'-10") (14'-8") 6 7 SIM 8 F1 ______ A3.01 (14'-9") SIM F1 ______ A3.01 MASONRY AND FLASHING REPAIRS AT: HUNTLEY 123 Elm St. Anytown, USA 12345 HIGH SCHOOL, HEINEMAN MIDDLE SCHOOL, AND MARLOWE MIDDLE SCHOOL NOTE: DIMENSION INDICATES LENGTH OF P.C. CONCRETE SECTION TO BE REMOVED AND REINSTALLED, TYP. SIM (11'-10") (11'-10") A HUNTLEY COMMUNITY SCHOOL DISTRICT #158 650 Academic Drive Algonquin, IL 60102 A1 IL NORTH ELEVATION 1/16" = 1'-0" F1 ______ A3.01 0 SIM 12' F1 ______ A3.01 (11'-10") F2 ______ A2.03 24' SIM F1 ______ A3.01 (11'-10") SIM F1 ______ A3.01 (11'-10") F1 ______ A3.01 F1 ______ A3.01 SIM SIM (9'-8") SIM SIM (9'-8") (9'-4") F1 ______ A3.01 F1 ______ A3.01 SIM F1 ______ A3.01 (9'-10") F1 ______ A3.01 SIM (9'-8") F1 ______ A3.01 SIM SIM SIM F1 ______ A3.01 (8'-6") F1 ______ A3.01 (9'-8") F1 ______ A3.01 (5'-2") SIM F1 ______ A3.01 (9'-8") SIM (13'-6") SIM SIM F1 ______ A3.01 (10'-4") (9'-8") (29''-6") B B1 SOUTH ELEVATION 1/16" = 1'-0" 0 12' F1 ______ A3.01 F1 ______ 24' SIM F1 ______ A3.01 (11'-9") SIM F1 ______ A3.01 A3.01 (9'-8") SIM F1 ______ A3.01 (5'-6") SIM F1 ______ A3.01 (8'-7") SIM SIM F1 ______ A3.01 (4'-8") F1 ______ A3.01 SIM F1 ______ A3.01 (14'-8") SIM SIM F1 ______ A3.01 (14'-4") SIM (14'-8") (10'-4") (9'-8") C C1 EAST ELEVATION 1/16" = 1'-0" 0 12' 24' F1 ______ A3.01 SIM F1 ______ A3.01 (14'-9") SIM (14'-8") F1 ______ A3.01 SIM (14'-8") F1 ______ A3.01 SIM F1 ______ A3.01 (11'-8") SIM (11'-10") F1 ______ A3.01 F1 ______ A3.01 SIM F1 ______ A3.01 (11'-10") SIM (12'-6") SIM F1 ______ A3.01 SIM (9'-10") (25') A1 A2.03 D D1 WEST ELEVATION 1/16" = 1'-0" 0 12' 24' KEYPLAN SIM (9'-8") F1 ______ A3.01 SIM I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed (9'-8") ARCHITECT Registration Number C1 A2.03 B5 A2.04 C1 A2.04 A1 A2.04 REV 0 6' 12' Description Comm: 163025 Date: 4/14/2016 Drawn: JRK Check: TS B1 A2.04 ELEVATION KEYPLAN Date Num North MARLOWE MIDDLE SCHOOL- EXTERIOR ELEVATIONS Scale: B1 A2.03 TEDD STROMSWOLD 001-020603 Date 4/8/2016 Revisions B3 A2.04 F A3 A2.04 1/8" = 1'-0" A1 A2.04 ENLARGED ELEVATION, TYP. A4 A2.04 F2 A IL under the laws of the State of E D1 A2.03 Central: L:\SD_Huntley\163025_Masonry and Flashing Repairs\163025_masonry and flashing drawings (central).rvt 4/14/2016 9:58:38 AM C:\Users\kgray\Documents\163025_masonry and flashing drawings (central)_kgray.rvt F1 ______ A3.01 As indicated A2.03 1 2 3 4 F1 ______ A3.01 F1 ______ A3.01 SIM F1 ______ A3.01 5 F1 ______ A3.01 SIM 8 MASONRY AND FLASHING REPAIRS AT: HUNTLEY 123 Elm St. Anytown, USA 12345 HIGH SCHOOL, HEINEMAN MIDDLE SCHOOL, AND MARLOWE MIDDLE SCHOOL NOTE: DIMENSION INDICATES LENGTH OF P.C. CONCRETE SECTION TO BE REMOVED AND REINSTALLED, TYP. (10'-5") (6'-1") (6'-1") 7 SIM (6'-1") SIM 6 A HUNTLEY COMMUNITY SCHOOL DISTRICT #158 A1 PARTIAL ELEVATION 1/16" = 1'-0" 0 12' A3 24' PARTIAL ELEVATION 1/16" = 1'-0" 0 12' A4 24' 650 Academic Drive Algonquin, IL 60102 PARTIAL ELEVATION 1/16" = 1'-0" 0 12' 24' IL F1 ______ A3.01 F1 ______ A3.01 SIM SIM F1 ______ A3.01 (5'-1") SIM F1 ______ A3.01 SIM (11'-9") (4'-7") (10'-2") B B1 PARTIAL ELEVATION 1/16" = 1'-0" F1 ______ A3.01 0 12' B3 24' PARTIAL ELEVATION 1/16" = 1'-0" 0 12' 24' B5 PARTIAL ELEVATION 1/16" = 1'-0" 0 12' 24' SIM (7'-1") C C1 PARTIAL ELEVATION 1/16" = 1'-0" 0 12' 24' A1 A2.03 D1 A2.02 B5 A2.04 ARCHITECT IL under the laws of the State of Registration Number TEDD STROMSWOLD 001-020603 Date 4/8/2016 Revisions C1 A2.04 Description A1 A2.04 A1 A2.04 A3 A2.04 A4 A2.04 Comm: 163025 Date: 4/14/2016 Drawn: JRK Check: TS MARLOWE MIDDLE SCHOOL- EXTERIOR ELEVATIONS B1 A2.03 ELEVATION KEYPLAN Num North B1 A2.04 F Date REV B3 A2.04 A I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed C1 A2.03 E D1 A2.03 Central: L:\SD_Huntley\163025_Masonry and Flashing Repairs\163025_masonry and flashing drawings (central).rvt 4/14/2016 9:58:38 AM C:\Users\kgray\Documents\163025_masonry and flashing drawings (central)_kgray.rvt D Scale: As indicated A2.04 1 2 3 4 5 6 7 8 MASONRY AND FLASHING REPAIRS AT: HUNTLEY 123 Elm St. Anytown, USA 12345 HIGH SCHOOL, HEINEMAN MIDDLE SCHOOL, AND MARLOWE MIDDLE SCHOOL NEW CAVITY WALL INSULATION OVER NEW FLEXIBLE FLASHING FIELD VERIFY ACTUAL CAVITY DEPTH (AT EACH OCCURANCE- DEPTH MAY VARY) CONTINUOUS STAINLESS STEEL TERMINATION BAR MECHANICALLY FASTENED @ 12" O.C., WITH MASTIC AT TOP, TYP. EXISTING CONC BLK BACK-UP WALL EXISTING CAVITY WALL INSULATION FLEXIBLE FLASHING- STOPS HORIZONTALLY UNDER TERMINATION BAR AND EXTENDS DOWN VERTICALLY AND HORIZ TO DAYLIGHT MORTAR NET A SPLIT FACE BLOCK EXISTING C. BLK BACK-UP WALL 26 GA GALVANIZED SHEET METAL CLOSURE W/ SLOPED 45 DEGREE SURFACE THRU CAVITY TO SUPPORT FLEXIBLE FLASHING. ANCHOR @ 18" O.C. TO EXISTING MASONRY BACK-UP WALL. UNDERBEND FOLDS TO ENSURE PROPER CONTACT WITH MASONRY BELOW. CELL VENT @ 16" O.C., TYP. EXISTING MASONRY VENEER EXISTING MASONRY VENEER TO REMAIN HUNTLEY COMMUNITY SCHOOL DISTRICT #158 650 Academic Drive Algonquin, IL 60102 PREFABRICATED END DAM MORTAR NET MASONRY VENEER TO BE REMOVED AND REPLACED NEW TERMINATION BAR MECHANICALLY FASTENED AT 12" O.C. IL CUT AND REPLACE EXISTING2" RIGID INSULATION WITH NEW 1.5" RIGID INSULATION TO INSTALL NEW FLASHING PROVIDE FLEXIBLE FLASHING UP AND OVER JOINT EXISTING MASONRY VENEER TO REMAIN 8" (TYP.) REINSTALL NEW MASONRY VENEER WHERE REMOVED FOR NEW WORK B 1" GAP +/- NEW GALVANIZED SHEET METAL CLOSURE BRIDGING WALL CAVITY TO PROVIDE SUPPORT FOR NEW FLEXIBLE FLASHING. ANCHOR TO C. BLK BACK-UP WALL AT 18" O.C.. UNDERBEND FOLDS TO ENSURE PROPER CONTACT WITH MASONRY BELOW. NOTE: WHERE END DAMS ARE CONCEALED BEHIND CONSTRUCTION TO REMAIN SEE F7/A3.01 PRE-FINISHED METAL RECEIVER SET RECEIVER AND SHEET METAL CLOSURE IN CONTINUOUS MASTIC BED. NEW FLEXIBLE FLASHING NEW PRE-FINISHED METAL RECEIVER SET IN MASTIC. PROVIDE MASTIC AT END LAP CONDITIONS. EXISTING ROOF MEMBRANE TERMINATION BAR 3" 7" 26 GA GALVANIZED SHEET METAL CLOSURE- LAID OVER LOWER END DAM 3" 1 1/2" CELL VENT AT 16" O.C., TYP. PREFABRICATED END-DAM NEW PRE-FINISHED METAL COUNTERFLASHING. PREFINISHED METAL COUNTERFLASHINGOVERLAP JOINTS MIN 4", ANCHOR W/ S ST SCREWS W/ NEOPRENE WASHERS @ 2'0" O.C., TYP. ROOFING SYSTEM AS OCCURS NOTE: AT SIMILAR LOCATION THE VENEER TO BE REMOVED AND REPLACED IS BRICK IN UTILITY SIZE PREFABRICATED END DAM ROOF MEMBRANE TERMINATION BAR (BY OTHERS- COORDINATE LOCATIONS WITH ROOFING CONTRACTOR) ROOFING MEMBRANE C C1 TYPICAL THRU-WALL FLASHING REPAIR DETAIL 3" = 1'-0" 0 3" 6" NOTE: INSIDE CORNERS ARE SIMILAR PRE-FABRICATED OUTSIDE CORNER, TYP. MITERED CORNER AT COUNTER-FLASHING TYPICAL THRU-WALL FLASHING AXON D4 NOT TO SCALE EXISTING C. BLK BACK-UP WALL D EXISTING 4" FACE BRICK MORTAR NET NEW TERMINATION BAR MECHANICALLY FASTENED AT 12" O.C. 2" CUT AND REPLACE EXISTING 2" RIGID INSULATION WITH NEW 1.5" RIGID INSULATION TO INSTALL NEW FLASHING 45 ° PRE FABRICATED END DAM (FOLD) TERMINATION BAR ADDITIONAL LAYER FLEXIBLE FLASHINGFOLD TO FIT 45 ° NOTE: FOR CLARITY NOT ALL MATERIALS ARE SHOWN. (FOLD) NEW GALVANIZED SHEET METAL CLOSURE BRIDGING WALL CAVITY TO PROVIDE SUPPORT FOR NEW FLEXIBLE FLASHING. ANCHOR TO C. BLK BACK-UP WALL AT 18" O.C.. UNDERBEND FOLDS TO ENSURE PROPER CONTACT WITH MASONRY BELOW. CAVITY DEPTH x2 (FOLD) 2" CELL VENT @ 24" O.C. NOTE: AFTER FABRICATION END DAM IS TO BE HOT-DIP GALVANIZED LD (FO ) 2" NOTE: SECTIONS OF PRECAST CONCRETE CAP TYPICALLY 3' LONG I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed ARCHITECT IL under the laws of the State of ) Central: L:\SD_Huntley\163025_Masonry and Flashing Repairs\163025_masonry and flashing drawings (central).rvt 4/14/2016 9:58:39 AM ROPE WEEP- ADHERE TO INSIDE CORNER OF FLEXIBLE FLASHING VENEER ANCHOR FOR EXISTING MASONRY (HB-200 OR EQUAL) AT 16" O.C., TYP. Registration Number TEDD STROMSWOLD 001-020603 Date 4/8/2016 SOLDERED AT CUT Revisions CAVITY DEPTH (x) EXISTING METAL AND FLEXIBLE FLASHING TO BE DEMOLISHED F4 LD (FO 45 CAVITY DEPTH (x) FLEXIBLE FLASHING EXISTING FACE BRICK & C. BLK END DAM RECESSED BEHIND OTHER MATERIAL SOLDERED AT CUT PREFINISHED METAL DRIP EDGE W/ HEMMED EDGE E LAP UNDER SHEET METAL CLOSURE. 2" MIN. LD (FO C:\Users\kgray\Documents\163025_masonry and flashing drawings (central)_kgray.rvt EXISTING BRICK AND ARCH PRECAST TO BE REMOVEDSALVAGE FOR REINSTALLATION. ) Description SOLDERED AT BEND 45 8" 2" TYPICAL PREFABRICATED END DAM DETAIL NOT TO SCALE Date F5 TYPICAL PRE-FABRICATED OUTSIDE CORNER NOT TO SCALE F7 TYPICAL CONCEALED END DAM CONDITION NOT TO SCALE Comm: 163025 Date: 4/14/2016 Drawn: JRK Check: TS North TYPICAL DETAILS A F F1 TYPICAL THRU- WALL FLASHING REPAIR DETAIL AT MIDDLE SCHOOLS 3" = 1'-0" 0 3" 6" Scale: As indicated A3.01 Num