National Core Field Guide, Version 3.0 October, 2005 Northeast Edition

advertisement
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
REGIONAL APPENDICES
Regional appendices that are found on the following pages have been added to assist with the P2 data
collection in the Northeast.
A. Plot Establishment in the Northeast
B. Ownership Data
C. Current Regional Land Use Classes
D. Tally Procedures in the Northeast
E. Tables and Charts
F. Shrub and Vine Species Codes for the Maine Inventory
G. Quality Control / Quality Assurance Program for the Northeast
H. Tally Record Guide
I.
Special Studies
J.
GPS User’s Guide
K. PDR User’s Guide
171
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
172
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Appendix A. Plot Establishment in the Northeast
This chapter describes how new sample plots are established and how remeasure sample plots are reestablished. Most remeasure plots that are revisited during this inventory have previous starting point
and course-to-plot information. On these plots, this previous information should be used and followed
unless there has been considerable change to the area; or there is a more efficient way to access plot
center. The course-to-plot information is updated at the time of each visit by the new crew to insure that
the plot can be relocated. It is critical that all plots can be relocated without the aid of GPS by using
standard compass and chaining procedures.
“Surveying in forest land as compared with work done in towns and on farms is carried out under
unfavorable circumstances. In the first place, timber and brush growth offer an obstruction to
sighting; second, the work is often done far from a well supplied base; third, the limits of cost allowed
are often the lowest practicable. These conditions have a strong effect upon the methods employed,
and they also affect the choice of outfit. Equipment for such work should not usually be expensive, it
should be as compact and portable as possible, and it should not be so delicate or so complicated as
to be likely to get seriously out of order and so hold up a job.” – Austin Carey, Woodsman’s Manual,
Fourth Edition,1932.
PLOT PHOTO ORIENTATION
The imagery used to aid in establishing sample plots can vary from state to state. Generally, when aerial
photography is being used, it will most often be products from the National Aerial Photography Program
(NAPP) or the National Agricultural Imagery Program (NAIP). NAPP products are usually 10” by 10”
contact prints with a nominal scale of 1:40,000. They may be color infrared, or black and white. NAIP
products are printed on to 8.5 x 11 in photo paper and have a nominal scale of 1:18,000. These may be
true color or color infrared. The main difference between the photography is that NAPP images are taken
during leaf-off and NAIP is taken during leaf-on. Crews may find it difficult to detect roads and other
features that occur within forest land when using NAIP.
When collected: All plots
Tolerance: No errors
The following procedures are used to orient the photography to magnetic north. The establishment of a
photo reference line is required for all plots. If both types of photography are issued (i.e., NAPP and
NAIP), complete the following on both.
•
Align the photograph so that the edge with the identification information is on top as you look at it.
That edge is the northern edge of the photo.
•
Select two features that can be identified on the photo; and on the ground, or on a topographic
map. Individual trees, road intersections, straight sections of road, buildings, field edges, or
unique locations along lakes and ponds, are good choices. Avoid railroad beds and power lines
because of their effect on compasses.
•
Using a pen, lightly connect the two selected features with a straight line (reference line). Be
careful when writing on the photos as the emulsion of the photo can be easily scratched.
•
Take a compass reading between the two selected features (magnetic azimuths are used). If
using a topographic map, determine azimuth from map.
•
Record the azimuth, and place an arrow at the end of the reference line, to show the direction of
the azimuth.
•
Record reference line and all photo calculations on page 4 of the plot record in the “Calculations”
section.
173
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
STARTING POINT
The starting point (SP) marks the beginning of the traverse to sample plot center (PC) and is required for
all plots.
When collected: All plots
Tolerance: See text below
An entire plot may be rated unsatisfactory if the SP is pinpricked incorrectly (i.e., off more than 1/50th of
inch), or if the SP is difficult to locate. Selection guidelines should be followed closely for all starting
points and witness trees. Pinpricks made by anything other than a fine pin or needle will not be tolerated.
Pinpricks are to be labeled on the back of the photo, and the locations of the SP and witness trees well
defined.
The SP should be:
•
Easily identifiable on both the plot photo and the ground
•
Likely to remain unaltered prior to the next inventory
•
Minimum of 200 ft from the plot whenever possible
•
Pinprick and label it as SP on the back of the photo
Witness the starting point with two trees or other nearby features, and record the pertinent information. If
SP and/or the witness features are trees, mark them with a bark scribe. Place two parallel diagonal
scribe marks, each about 4 inches long and 4 inches apart, at 5-1/2 ft above ground, and near the
ground, below an imaginary 1 ft high stump. The lower scribes are referred to as stump scribes. Place
the stump scribes on the downhill side of the tree whenever possible. Scribe marks on witness trees will
face the SP. (If the witness tree is located on a slope, stump scribes should be placed on the downhill
side of the tree.) On SP trees, they will face the direction of approach so that future crews may readily
find them. Never place scribes of any type on trees located on a landowner’s yard without
permission from landowner.
Make the scribe marks in the outer bark layer of the tree. DO NOT CUT THROUGH THE CAMBIUM. It
is important that scribe marks be made carefully so that they do not expose or penetrate the cambium of
the tree.
Scribe marks that penetrate the cambium may provide a vector for insects or disease. And, on thinbarked trees, can cause deformities that may interfere with diameter measurements at subsequent
inventories. Use tree paint on thin-barked trees such as beech, and on smaller sized trees of all species.
The use of scribes and paint are prohibited on plots located in Wilderness areas on National Forests.
Starting point trees and their witness trees will not be painted or scribed. Instead, nail a tag marked with
"SP" to the base of the tree facing the direction of normal approach. Similar for witness trees, nail a tag
marked “SP WT” to the base of the tree facing the starting point. If the starting point is in the view of a
known path, trail or other public area, place the tag away from the public area. In addition describe the
starting point on the plot record and include reference landmarks. If old scribe marks are present, do not
re-scribe. Apply tags as instructed. [INTRA-AGENCY AGREEMENT 05-SU-FIA01]
174
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Illustrations of Scribing
Crew passed tree on
the left side.
Witness tree
Line tree
COURSE TO PLOT
There are two methods to establish a course to plot: aerial photography and Global Positioning System
(GPS) coordinates.
When collected: All plots
Tolerance: See text below
A plot must be established at the correct location, and in a manner, which facilitates the efficient return,
by future crews. Distance to the plot, measured from the aerial photograph, should be within one half of
one 1/50 of an inch, from the same measurement of an inspector. If GPS coordinates were used to
determine course to plot, coordinate collection procedures as written in this Appendix J should be
followed.
Although a compass line may not read the same as the inspector's, it must be accurate once it is
established. Carefully check all calculations in the area provided on page 4 of the plot record. Draw and
label the reference line and the traverse line on the face of the aerial photograph, if applicable. Again if
GPS coordinates were used to determine course to plot, collection procedures as written Appendix J
should be followed.
The tolerance for 100 ft chaining intervals varies from ± .5 ft to ± 2.0 ft, depending on the slope of the
traverse and the density of ground cover. It is important that tapes be kept straight in both the horizontal
and vertical planes when "chaining". Accuracy over the entire traverse should be within 2 ft per every
1000 ft of the calculated distance.
Slope corrections must be within +/- 5 percent. Line trees must be established and species must be
identified correctly. If something other than a tree is referenced, it must be noted. Other line tree
requirements are:
•
DBH must be within 2 inches
•
Distances must be within 2 ft
•
Direction must be within a one hour interval
•
Scribes must point in the correct direction
•
Make a note when the line crosses a stream, fence or boundary line.
175
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Depending upon the state, there are several methods for plot establishment.
Remeasure plots (SAMPLE KIND 5, 6, 7 and 8) were established and are re-established by using
aerial photography. (See Note) When plots are being re-established (i.e., old SP and course to plot no
longer available), the original photography and photo scale is used, if available. Draw a thin line on the
photograph connecting the SP and the PC. Measure the length of this line to the nearest 1/50 of an inch
and multiply that number by the conversion factor (40 for 1:24,000 and 66.7 for 1:40,000 photograph).
This is the distance to be traversed. Check your calculations carefully. Record the distance in the space
provided in the COURSE TO PLOT on page 4 of the plot record. Any remeasure plot that has a new
course-to-plot established must be documented with calculations, photo work and why the old
course-to-plot was not used. Lack of documentation is considered unsatisfactory work. If a
forested plot requires re-establishment, it is important that the current crew occupies the same ground
location as the previous crew. If a crew has any difficulty in re-establishing a forested plot, they are to
contact their field supervisor for assistance. If the plot cannot be relocated, then the field supervisor will
authorize a replacement plot.
Warning: If a remeasure plot is located using the old course-to-plot information; do not calculate a new
course-to-plot from SP and PC coordinates unless this distance has been traversed on the ground. The
reason is that the calculated distance and azimuth from GPS coordinates has an associated error for SP
to PC. If this new course-to-plot is not traversed, the next crew may not find the exact ground location
especially if there has been major change to the area and witness trees and tally trees have been
removed. The same is true for new plots. If you complete a course-to-plot and decide there is an easier
route to the plot by creating a new SP, this new course-to-plot must be traversed on the ground.
If the course-to-plot is not traversed on the ground, the plot record is noted (e.g., C to P not run).
Note: ME and PA SK 2 plots and DE, MD and WV SK 5 plots, that were SK 1 on the last occasion, were
established from the coordinates on the plot record label. If these plots were “nonforest” and not
established (i.e., PC coordinates were not taken at PC), then the label coordinates were recorded as the
PC coordinates. Even though there was recorded course to plot information, this information was not
used to determine PC coordinates or recorded as the PC coordinates. The reason is that the label
coordinates for these plots represent the true ground location without any error. To re-establish this plot
today simply verify that the old SP is still acceptable. If it is, simply transfer the previous course to plot
information and the PC coordinates from the plot label. If the SP is no longer acceptable and a new SP is
established, calculate a new course to plot from the new SP coordinates and the PC label coordinates.
The label coordinates are still recorded as the true PC coordinates unless you complete the traverse to
PC and collect coordinates over PC.
As each state rolls into annual remeasurement (SK 2 plots), the plot record label will reflect GPS
coordinates and the digitized coordinates will be a matter of record on previous periodic inventory tally
records.
PHOTO CALCULATIONS PROCEDURE
Extend the line from SP to PC so that it intersects with the reference line. With a protractor, measure, to
the nearest degree, the angle between the two lines. Add or subtract this angle to the known azimuth of
the reference line to determine the azimuth from SP to PC. If the two lines do not intersect, draw offset
lines that will provide intersections. Check your calculations carefully. Record the azimuth in the space
provided on page 3 of the plot record. Proceed with the traverse to PC.
176
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Azimuth Calculations
azimuth 030
road
azimuth 120
(030 + 090)
090
080
045
azimuth 200
(120 + 080)
azimuth 345
(030 - 045)
reference lines
approach lines
starting point
plot center
New plots are established by using GPS coordinates. (See Appendix J for specific GPS unit use and
collection procedures.)
For new plots established by GPS coordinates, crews must be within 100.0 ft of the label coordinates for
satisfactory plot establishment.
Remeasure plots that have GPS coordinates collected during the last inventory can be relocated by
GPS unit navigation methods. Crews must update the SP information so that the plot can still be located
by more traditional means of compass and chain. If there is no change in the SP, then the course to plot
azimuth and distance is transcribed to the new plot record. Crews are not required to update the 100 foot
chaining intervals unless there has been significant change to the area. Anytime a new SP is
established, then a new course to plot must be completed and traversed.
CHAINING TO THE PLOT
Using a compass and a 100 ft tape, begin the traverse to the plot. For all new plots, use the course to
plot calculations from the previous section to eliminate any bias of the PC ground location. Two people, a
head chainperson and a rear chainperson, are needed for accurate measurements. The head
chainperson, by using a compass, must keep themselves and the tape on the correct bearing line at all
times. In areas with dense undergrowth, or an extreme amount of slope, it will often be necessary for the
rear chainperson to direct the traverse. Be careful to avoid tangles, loops, or bends in the tape.
Once the rear chainperson reaches the new station, select a tree (or other feature) for line reference. For
trees record:
•
Appropriate species code
•
Diameter at breast height (DBH), estimated to the nearest even two-inch diameter class
•
Estimated distance, in feet, from the station to the line tree
177
•
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Direction from the station to the line tree, using the clock system, with the direction of the traverse
as 12 o'clock
Scribe line trees at about 5-1/2 ft high and facing the direction of approach. Slant the bottom of the
scribes to the left "//” or the right "\\” to indicate which side of the line tree the crew passed. Stump
scribes are not used on line trees.
Make note of when the line of travel crosses streams, fences, or other unique features. To avoid
confusion with trees tallied on the sample plot, do not mark any line tree within the last 150 to 200 ft of the
course.
In rough terrain, it may be necessary to "break chain", i.e., to use short sections of the tape to aid in
holding a level line. Record descriptive notes in these cases. In mountainous country where horizontal
distance cannot be chained directly, measure slope distances and convert to horizontal measurements as
described in the next section.
The use of scribes and paint are prohibited on plots located in Wilderness areas on National Forests.
Line trees are not marked or tagged. Instead record the species, DBH, distance and direction. If old
scribe marks are present, do not re-scribe. Any flagging used to facilitate entry and exit from the plot area
will be removed upon completion of the plot measurements. [INTRA-AGENCY AGREEMENT 05-SUFIA01]
CHAINING SLOPE DISTANCES
The forward chainperson proceeds up or down slope for the full length of the 100 ft tape. The rear
chainperson then uses the clinometer to determine the slope percentage between his or her position and
that of the forward chainperson. Knowing the percentage of slope and the distance (usually 100 ft),
determine the slope correction from the prepared tables in Appendix E. The rear chainperson then
makes the adjustment by adding the proper distance to the nearest 1/10 ft to the 100 ft tape. Then the
forward chainperson stretches the tape taut again along the slope and sets the new distance. Record the
slope correction, in actual feet and tenths of feet, in the Course to Plot information found on page 3 of the
plot records. Slope corrections are always added along the slope, never subtracted.
The example below illustrates how to record course to plot information on page 3 of the plot record.
COURSE TO PLOT
HORIZONTAL DISTANCE
AZIMUTH
351 FEET
DIST
SC
SPP
000
----
SP
100
000
0802
200 DEG
DBH
DIS
DIR
12
9
1
160
NOTES
STREAM
200
024
300
016
351
----
0403
8
2
10
1 OF 2
NO SCRIBE
PC
178
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
ESTABLISHING SUBPLOTS 2 - 4 WHEN SUBPLOT 1 IS INACCESSIBLE
At times, subplot 1 can be inaccessible due to unsafe conditions such as heavily traveled roads or deep
bodies of water. The following example illustrates how to locate subplots 2 - 4 when subplot 1 is
inaccessible.
In the example on the next page, the stream is noncensus water that is too deep to access or cross. The
crew establishing the plot does not know that the subplot is inaccessible until they encounter the stream
while chaining from SP to PC.
State Rt. 3
*
State Rt. 100
SP
PC
State Rt. 7
Originally, the course to plot was 534 ft at 150°. The crew chains 500 ft to the edge of the stream and
they realize that they cannot occupy subplot 1.
To establish subplot 2 without occupying subplot 1, the crew should establish a turning point (TP1) at
the 400 ft station of the course to plot and proceed due north for 120 ft. Here a second turning point
(TP2) is established and the crew should proceed 134 ft at the original course to plot azimuth of 150°.
This is the proper location of subplot 2. Note that TP1 could be established at any subplot along the
original traverse as long as the distance from TP2 to subplot 2 is adjusted as well.
SP
TP2
*
subplot 2
TP1
subplot 1
After completing the tally at subplot 2, subplots 3 and 4 now need to be established. Since the creek
divides subplot 3 from the rest of the plot, and the stream cannot be safely crossed, subplot 3 will have to
be accessed from the opposite side of the creek.
179
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
As for subplot 4, it can be accessed directly from subplot 2. The distance and azimuth from subplot 2 to
subplot 4 is 207.8 ft at 210°. (See the table in Section 0.1 showing how to locate outer subplots from a
subplot other than subplot 1.)
subplot 2
207.8’ at 210°
subplot 1
subplot 3
subplot 4
Finally to complete subplot 3, the crew will need to access this subplot from the other side of the
stream. A second SP and course to plot is established using the aerial photography. (Note: If this
procedure is followed for a new plot, you must first accurately pinprick the PC ground location and orient
the photo.) Example below: SP #2 to PC is 400 ft at 220°.
*
State Rt. 100
State Rt. 3
SP#1
*
SP #2
State Rt. 7
However, we cannot occupy P.C. and the goal in establishing a second SP and course to plot is to
establish subplot 3. This can be accomplished by proceeding 120° for 120 ft from SP #2 to a turning
point. This turning point represents the relative location of subplot 3 to subplot 1. From the turning point,
proceed on the calculated course to plot of 400 ft for 220° to locate subplot 3. This procedure uses the
same techniques as used to locate subplot 2 from the original course to plot.
180
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
SP #2
Chain 120’ at 120°
*
subplot 2
•
TP
subplot 1
Chain 400’ at 220°
subplot 4
subplot 3
This is just one example to illustrate locating subplots without occupying subplot 1. Another method that
can be utilized is using the GPS unit. In the above illustration, the coordinates at subplot 3 can be
determined from the subplot 1 coordinates. Coordinates are then collected at SP #2. A course to plot
can then be determined from these two sets of coordinates. However, caution must be used when
establishing subplot 3 in this method. All GPS coordinates involve error. Therefore, prior to any data
collection at subplot 3, the crew should verify, the best they can, that they are the proper distance and
azimuth from the other subplots.
Crews should implement a method that is most efficient given various conditions that exist on the photo
and plot area.
Whenever subplots are established without occupying subplot 1, a detailed description of the methods
used must be written in the PLOT LOCATION NOTES and course to plot sections of the plot record.
Photos with more than one SP and course to plot must be properly labeled. Also whenever subplot 1 is
not physically occupied, the crew should monument one of the subplots (2-4) with witness trees and
collect GPS coordinates at this point. These coordinates are recorded in the PLOT LOCATION NOTES
on page 4 of the plot record only.
AT PLOT CENTER
For a new plot you will need to pinprick the PC ground location on the photography. (To accurately
pinprick PC, use ground observation, photo reference line, topographic map, scale and stereoscope.) If
you cannot accurately pinprick PC, the plot record should be noted. For example, “Accuracy of PC
pinprick questionable due to extreme change and/or age of photography.” The PC pinprick is utilized for
other office applications such as forest fragmentation studies and remote sensing.
Plot that is being remeasured, it is important to check to see where you are on the photograph. Although
the previous instructions may have taken you right to plot center, the plot may still be in a different
location than the one marked on the photograph. If you determine that the plot is located incorrectly on
the photograph, correct the pinprick not the plot’s physical location. Changes should be documented on
the back of the photograph and the PLOT LOCATION NOTES.
When collected: All plots
Tolerance: See text below
PC must be located correctly and the PC witness trees must be accurately recorded, or the entire plot will
be considered unsatisfactory. Also an entire plot may be rated unsatisfactory if the PC is pinpricked
incorrectly (i.e., off more than one 1/50th of inch for NAPP and two 1/50th of inch for NAIP).
181
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
For new plots established by GPS coordinates, crews must be within 100.0 ft of the label coordinates for
satisfactory plot establishment.
For remeasured plots, the plot must be relocated at the same location that it was previously established.
In the rare case when it appears that the previous crew established a plot in the wrong location it is
important that it be reestablished at that same location. The data from such a plot can still be very useful.
Complete the plot and bring the situation to the attention of the field supervisor.
If the ground location does not agree with the photo location, consider the following:
•
Was the starting point correctly identified and marked on the photo?
•
Was the photo distance measured correctly, or were the correct GPS coordinates used?
•
Is the photo scale correct for the local area?
The scale of the photo can be determined by solving the following formula for X. Remember to convert
the photo distance and the ground distance to the same units of measure.
1
X
=
photo distance
ground distance
If the actual scale of the photograph is 1:38,000, then the conversion factor would be 63.33 ft per .02
inches. For each 100 ft of traverse, this would be a 3.3 ft difference, less than calculated, from a nominal
scale of 1:40,000.
•
Are the reference line and course to plot azimuths correct?
An error of 1 degree would cause a 1.7 ft deviation, left or right, per 100 ft of traverse. A 5 degree error
would, over a mile, end a course 20 ft behind and more than 460 ft to the right or left of the true location.
•
Were slope corrections added along the course?
In previous inventories, a procedure of locating plots “by inspection” may have been practiced. In this
procedure the crew that originally established the plot did not set up a course to plot with a distance and
azimuth calculated from SP to PC. Most plots established in this matter were located immediately off a
road edge or in small wood lots where locating PC directly from the photo seemed sufficient. This
procedure is no longer acceptable. Plots determined to have been established by inspection will be
rated as a failed plot.
Never locate plots “by inspection."
When a plot cannot be relocated, write a thorough description of where you looked and your conclusions.
Most likely, a different crew, or a supervisor, will try to relocate the plot. This information will be very
helpful to them.
Remeasured plots (SAMPLE KIND 5 – 8), where PC has never been established and witnessed, must
match the old “office” pinprick location. (This pertains to remeasured plots where the original course-toplot was established using photography and not GPS coordinates.) For example, the old photo pinprick
indicates that the plot fell in cropland 200 ft from the edge. The old course-to-plot places you 200 feet
into the forest. Do not establish the plot in the forest. Place a turning point in the course-to-plot so that
the ground location matches the old photo location.
182
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
PLOT CENTER WITNESS
In the space provided, note that a wooden dowel was used to monument plot center.
When collected: All plots with accessible forest land
Tolerance: No errors
Select two witness trees that are:
•
Close to the dowel and spaced approximately at right angles from the dowel.
•
Easily recognized species that stand out from others in the area.
•
At least 3 inches DBH -- larger if possible.
•
Not expected to die, or be cut, in the next 10 years
For each witness tree, record:
•
The horizontal distance, to the nearest .1 (1/10) feet, from the dowel to the center of the base of
the tree.
•
The azimuth, to the nearest degree, from the dowel to the center of the base of the tree.
•
The appropriate species code.
•
The DBH (round measurement down to the last whole .1 (1/10) inch)
•
Under notes, anything distinctive about the tree, example: “forks at 4 ft", “clump of 3”, etc.
Enter the tree number if the witness tree is also a tally tree. This is determined during the tally procedure.
If no witness trees are available, use some other features and record descriptive notes.
Any subplot that does not have at least two trees tallied on the subplot is referenced. Subplot witnesses
are used whenever there is a concern that the next crew may have a problem locating a subplot. Make
complete notes of everything that you do so that it will be clear to the next crew.
Note: Wooden dowels are used to monument subplot centers and metal pins are used to monument
microplot centers. If a dowel or pin cannot be placed, then it should be noted on the plot record.
The use of scribes and paint are prohibited on plots located in Wilderness areas on National Forests.
Plot center witness trees will not be painted or scribed. Instead, nail a tag marked “PC WT” to the base of
the tree facing the PC. Similarly if a subplot requires referencing, nail a tag marked “S1 WT” facing the
subplot center. (The “S1” relates to subplot 1. If referencing a different subplot, change this value to 2, 3
or 4.) If old scribe marks are present, do not re-scribe. Dowels and pins, that mark subplot centers and
microplots, may not protrude from the ground more than 1 inch. Flagging may not be attached to the
marker. Temporary markers, such as flagging, may not remain in place for more than one week when
field crews are not present on a site. Paint, or similar semi-permanent markers, may not be applied to
rocks, plants, or other natural surfaces. [INTRA-AGENCY AGREEMENT 05-SU-FIA01]
183
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
PLOT DIAGRAMS
Use this space to show the location of contrasting condition classes, and any unique features on or near
the plot that may be helpful in relocating the plot at the next inventory. It is important that condition class
boundaries be sketched in accurately to avoid problems on the next inventory when these boundaries will
be remeasured. See Plot Diagram Rules in Appendix D.
When collected: All plots
Tolerance: No errors
SKETCH MAP OF PLOT LOCATION
A sketch map of the general area surrounding the plot must be drawn for all plots.
When collected: All plots
Tolerance: See text below
Sketch maps should provide enough information so that a plot can be relocated without the use of the
aerial photos or GPS coordinates. Details (bridges, rivers, trails, etc.) and mileage to an easily located
intersection or reference point must be included. Inspectors check the quality of a sketch map by
attempting to locate a plot with the sketch map. A plot that cannot be located due to a poor sketch will be
considered unsatisfactory. Neatness and clarity are desired. Artwork is not necessary and is not
required. A good sketch map should take no more than five to ten minutes to complete.
It must include:
•
References to the two nearest towns;
•
Names and/or numbers (if available) for all roads shown on the sketch along with house or box
numbers, when appropriate;
•
Intersections and other easily identified landmarks.
•
Location of SP and PC.
•
Record distances between road intersections from an originating intersection or town to SP.
Distances are recorded in miles, tenth’s of mile, chains, or feet.
OWNERSHIP AND PLOT LOCATION NOTES
Record any additional information regarding ownership, plot and/or subplot relocation.
“Notes should be full and exact so as to furnish for the benefit of later comers a complete record of
the work done. In the case of resurveys they should be particularly clear as to the old marks found,
so that the evidence which governed in the resurvey may be a matter of record. This rule holds
especially in regard to starting points and corners…Notes should be so plainly and clearly written that
any fairly intelligent man can understand them. They should be honest as well, not concealing actual
errors...Errors are normal and to be expected. They grow out of imperfections in method that are
imposed on the survey or by limitations in the matter of expense. Errors are not to be confused with
mistakes or blunders.” – Austin Carey, Woodsman’s Manual, Fourth Edition,1932.
184
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
P3 PLOT ESTABLISHMENT AND RECONCILIATION
There is always a bit of confusion as to what needs to be tallied, reconciled, etc. on a P3 (former FHM)
plot. The P3 tally guide for saplings and trees should alleviate some of the confusion for required
variables. The other problem is the confusion of the multiple sample kinds for P3 plots. The following is
an explanation by state and sample kind as what procedures should be followed for plot establishment
and reconciliation, if applicable. The information below is written for the 2005 P3 data collection. Those
states beginning annual remeasurement (SK 2 plots) will follow the information written for Maine and
Pennsylvania.
P3 Sample Kinds by State
Maine and Pennsylvania
•
SK2 P3 Plot# ≥ 0001 – previously established annual P3 plot (P3 annual remeasurement plot)
Connecticut, Massachusetts, New Hampshire, New Jersey, New York, Ohio, Rhode Island and Vermont
•
•
•
SK1 P3 Plot# ≥ 5000 – A new annual plot, never established (new to P3)
SK1 P3 Plot# < 5000 – A previously established periodic FIA plot (new to P3)
SK5 P3 Plot – A previously established FHM 4-point plot by an old FHM crew that may overlay an
old periodic FIA plot (P3 remeasurement plot). This SK is not valid in Ohio.
Maryland and West Virginia
•
•
SK1 P3 Plot – A previously established periodic FIA plot (new to P3)
SK5 P3 Plot – A previously established FHM 4-point plot by an old FHM crew that may overlay an
old periodic FIA plot (P3 remeasurement plot).
Delaware
•
•
SK5 P3 Plot – A previously established FHM 4-point plot by an old FHM crew that may overlay an
old periodic FIA plot (P3 remeasurement plot).
SK5 P3 intensified Plot – A previously established periodic FIA 4-point plot by an old FIA crew
that has been converted to P3 for state use only. The additional P3 data is not used for national
P3 reports. (P3 remeasurement plot).
Plot Establishment and Reconciliation Procedures by Sample Kind
•
SK2 P3 Plot (P3 annual remeasurement plot) – Re-establish the plot and collect all the P2 and
P3 variables required and reconcile tree and sapling data from provided reconcile sheet.
•
SK1 P3 Plot (new to P3) – Establish the plot as any other new plot and collect all the P2 and P3
variables required.
•
SK1 P3 Plot (previously established periodic FIA plot, new to P3) – The old FIA data is used only
to relocate the plot. All other information is ignored and the plot is established as if it were a new
P3 plot. At subplot 1 assign new tree numbers to all trees beginning with 001.
Note: There may be an FIA reconcile sheet associated with these plots. Do not reconcile this
FIA information. Use the FIA reconcile sheet only to aid in re-establishing the plot.
•
SK5 P3 Plot (P3 remeasurement plot) – Requires reconciliation and relocation to the old
FHM data and not any previous periodic data from old FIA tally sheets. Reconcile all trees listed
on the provided P3 (FHM) reconcile sheet including dead trees and saplings. Account for all new
185
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
dead trees or snags. Do not tally new dead saplings. Assign tree numbers to new trees (first
available new tree number = last previous FHM point tree number + 1).
Note: There may be an FIA reconcile sheet associated with these plots. Do not reconcile this
FIA information. You may also find that the FHM ground location and the FIA ground location
do not match. The FHM location supersedes the FIA location and the FHM data is reconciled.
When these situations are encountered, make a notation on the tally sheet and inform your field
supervisor. Occasionally the previous FHM ground location cannot be located due to lack of
documentation and the crew has exhausted ever means known to them to find this location. The
crew proceeds to find the FIA ground location from the periodic inventory. If this location is found,
the crew must complete the plot on paper and this plot is treated as a new. The crew documents
this plot as needing special attention by Information Management in Newtown Square.
•
SK5 P3 intensified Plot (P3 remeasurement plot) – Requires reconciliation and relocation to
the old periodic FIA data and not any previous FHM data.
186
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Appendix B. Ownership Data
The determination of ownership is used to code OWNER GROUP when CONDITION CLASS STATUS is
1 at plot center (PC) of subplot 1.
OWNERSHIP INFORMATION
Ownership is usually one of the first variables completed by a field crew. The process begins with a trip
to the local tax office to review plat maps, examine aerial photos and interview the tax collector in an
attempt to determine who the owner of the property is where the plot is located. Once the general
location of a plot is known, attempt to contact the landowner for permission to install the plot and to
confirm the landowner's complete mailing address.
It is frequently not possible or practicable to contact a landowner prior to installing a plot. However,
permission must be obtained if the property is posted against trespassing. There may be other
problems related to accessing a plot. Advance notice may be required to obtain keys, special permits,
etc., prior to property access. Supervisors will provide assistance and instructions for these and other
situations.
In situations where landowners cannot be contacted by phone or on site, a standard letter is sent by the
state supervisor to request permission to access the plot. Included with the letter is a reply card for the
owner with a preaddressed, postage paid envelope. If a reply is never received or a reply returns with no
permission granted, the plot is indicated as denied access and denied access data variables are
recorded. (See standard landowner letter at the end of this appendix.)
Although ownership information is only required for plots that are forested at PC, it is often a good idea to
collect ownership information on all of the plots in the county, or town, while you are at the tax office. This
is especially true in states or regions where there is a relatively small amount of nonforest land. The time
spent gathering this extra information during your first visit to the tax office will usually be a fraction of the
time spent on a return visit after you discover that a previously nonforest plot has reverted to forestland.
When Collected: CONDITION CLASS STATUS = 1 at plot center of subplot 1
Field width: Variable
Tolerance: No errors
MQO: At least 99% of the time
Values: Alpha/numeric
Enter the data as follows:
•
•
•
•
•
•
Enter one (1) letter or character per space.
If more space is needed, continue on the second line.
If the first line is adequate for the name, begin the address on the second line and continue on
through the third line if needed.
The fourth line is used only for the city or town, state, and zip code.
Enter the source of the information e.g., owner, town clerk, neighbor, tax maps, on the indicated
line.
On the last line, enter the identification numbers (township, plat number, lot number, deed
number, etc.) of the information, if they are available.
See example on next page.
INFORMATION QUALITY
Enter a code that best describes the reliability of the ownership information.
187
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
When Collected: CONDITION CLASS STATUS = 1 at plot center of subplot 1
Field width: 1 digit
Tolerance: No errors
MQO: At least 99% of the time
Values:
0
Unknown
1
Poor, somebody thought the owner was....
2
Good, source was neighbor or someone who was quite sure
3
Verified, information came from owner, tax maps, public agency, or more than one reliable
source.
OWNER CONTACT
This area of the plot record covers several variables related to landowner contact. This information is
very helpful when a sample plot has to be visited more than once. There is an area to document attempts
made to contact a landowner, as well as the method that permission was obtained. There is also an area
to indicate whether the property, where the center subplot is located, is posted to prevent trespassing.
These variables must be completed for all plots with forest land, and may also be helpful on some of
the nonforest plots. If applicable, complete all the information for this variable on the plot record.
When Collected: CONDITION CLASS STATUS = 1 at plot center of subplot 1
Field width: Variable
Tolerance: No errors
MQO: At least 99% of the time
Values: Check Yes or No, or indicate appropriate information
Plots that Straddle Multiple Owners – During the course of obtaining ownership information from public
tax offices take special note of plots that are close to, or overlap, a parcel boundary. If these situations
are noted during the ownership collection process and the name and address of the second landowner
are acquired, then it becomes possible to ask permission of that landowner at the beginning of the
process instead of risking delay and refusal after work on the plot has already begun. This may also be if
help if delineating condition class by OWNER GROUP.
Note: Some publicly owned lands like national parks and wilderness areas require permits for access
and data collection. Crews working in New York must have a permit to access all state owned lands.
Contact your field supervisor for assistance in obtaining these permits.
188
United States
Department of
Agriculture
Forest
Service
Noreastern Research
Station
11 Campus Blvd., Suite 200
Newtown Square, PA
19073-3200
File Code: 4801
Date: <February 24, 2003>
<John & Jane Landowner>
<666 Briar Patch Rd.>
<Sometown, PA 12345>
Dear <Mr. & Mrs. Landowner>:
The USDA Forest Service, Forest Inventory & Analysis project is currently conducting a new statewide
inventory of <Pennsylvania’s> forest resources. Our unit is responsible for performing such inventories
on approximately 100 million acres of federal, state, and private forestland across 13 Northeastern states.
Their purpose is to provide information about our Nation’s forest resources; what these resources are,
how they are being used and how they are changing.
One of our sample areas is located on your property in <Chester> County, <Pennsylvania>. We would
like your permission to visit this sample area so we can collect the data needed for this inventory.
In brief, our crews collect information on a plot approximately 0.6 acres in size. Such information includes
size, volume, and quality of all tree species present, forest type, the presence of insects and disease, and
other similar variables. This information will then be combined with data from other research sites across
the state and a statistical report will be published soon thereafter. More information is available on our
website: http://www.fs.fed.us/ne/fia
The locations of these research plots are chosen at random, and are not specific to individual
landowners. All information about the landowner, as well as the location of the research site is kept
confidential. We are not involved with property assessments or taxes, and we do not buy or sell timber or
land.
Again, we would like your permission to visit this sample area so we can collect the data needed for this
inventory. Please respond, whether you agree to participate in this inventory or not, by checking the
appropriate space on the enclosed response sheet, and sending it back in the stamped envelope.
If you have any questions or comments or would like to further discuss any aspects of our inventory, feel
free to contact me at your convenience. I may be reached at the address above, by phone at <(XXX)
XXX-XXXX>, or by email at <statesupervisor@fs.fed.us>.
Thank you for your time and cooperation.
Sincerely,
<SUPERVISOR’S NAME>
Forester
Forest Inventory & Analysis
Caring for the Land and Serving People
Printed on Recycled Paper
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
TO: USDA Forest Service; Forest Inventory & Analysis
From: <John & Jane Landowner>
Re: Research Access
_____ Yes, you have permission to access my property to conduct research for the state inventory. I
understand that the Forest Service is responsible for any injuries that may occur while their
employees are on private land, and that I will be protected from any liability.
_____ No, I do not want to participate in the state inventory. Please do not access my property.
190
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Plot Ownership Data Program – This data entry program resides on the laptop. Crews have the
responsibility of entering all ownership data for plots where subplot 1’s PC is forested. If subplot 1’s PC is
nonforest, ownership information is not entered even if there is forest land on the plot.
Note: Subplot 1’s PC ownership information can be recorded for all plots on the page 3 tally sheet for
determining access and permission. However, the ownership program requires only the ownership
information where PC at subplot 1 is CONDITION CLASS STATUS 1. Crews may want to make a
notation in the ownership block for those plots where PC is nonforest at subplot 1 (e.g., Nonforest @ PC).
Crews are to periodically submit this electronic data to Newtown Square. The frequency of submission
will vary by state and/or duty station. Data can be sent to Newtown Square throughout the year. Your
field supervisor may have suggestions as to when data should be sent (e.g., completion of a county,
completion of a sub-cycle, every quarter, etc.).
Any questions or problems concerning the Plot Ownership Data program should be directed to Mary
Miller at Newtown Square.
191
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
192
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Appendix C. Current Regional Land Use Classes
The following land use definitions and codes contain new definitions and codes that are used to describe
Other Forest Land and Christmas Tree Plantations. The concept of Other Forest Land is a significant
departure from the way land use has previously been classified by FIA at the Northeastern Research
Station. All field employees are advised to read this section carefully, and to ask questions if there are
any concerns. It is your obligation to understand these instructions and apply them consistently.
All plots that change LAND USE and/or CONDITION CLASS STATUS from the previous inventory
are verified by the state supervisor or QA personnel by either a second field visit or review of plot
records and photography. It is critical that land use is correctly classified so that change between
the inventories can be assessed.
FOREST LAND
Land that meets the definition of accessible forest land as described in Section 2.2. Grazed woodlands,
reverting fields and pastures are included if the area meets the criteria of accessible forest land. In the
Northeast, land that is partially developed, maintained or managed for pasture and grazing, and meets
the criteria of accessible forest land except for “intensive grazing” is classified as forest land.
Following are the forest land use definitions and codes for regional variable 2.50NE. Use these
codes in conjunction with CONDITION CLASS STATUS 1.
20 – TIMBERLAND
Forest land that is producing or capable of producing crops of industrial wood in excess of 20 cubic
feet per acre per year, and is not withdrawn from timber utilization by statute or administrative
designation. (Land withdrawn from timber utilization must be publicly owned land. See the
definitions of Reserved, Unproductive Reserved, and Reserved Other Forest land.) Timberland may
be nonstocked provided that neither any natural condition, nor any activity by humans, prevents or
inhibits the establishment of tree seedlings.
30 – OTHER FOREST LAND
Forest land that is producing, or capable of producing, crops of industrial wood, but is associated
with, or part of a nonforest land use. In the past, these areas would have been treated as inclusions
in the nonforest land use because they were considered part of a development. Some examples of
land that could be classified as other forest land are forested portions of city parks, forested land in
highway medians and rights-of way, forested areas between ski runs, and forested areas within golf
courses. Generally, although surrounded by nonforest development, these areas have not been
developed themselves, and exhibit natural, undisturbed understories.
31 – UNPRODUCTIVE OTHER FOREST LAND
Other forest land that is incapable of producing 20 cubic feet per acre per year of industrial wood
under natural conditions, because of adverse site conditions. Crews must include documentation of
why the condition is considered unproductive in the PLOT NOTES. Adverse conditions include
sterile soils, dry climate, poor drainage, high elevation, steepness, and rockiness. Vegetation, if
present, is widely spaced and scrubby, or tree growth cannot become established. These conditions
can be due to forces of nature or human-caused disturbances.
32 – RESERVED OTHER FOREST LAND
Publicly-owned other forest land that is sufficiently productive to qualify as timberland, and is
withdrawn from timber utilization by law.
33 – UNPRODUCTIVE RESERVED OTHER FOREST LAND
Publicly-owned other forest land that is incapable of producing 20 cubic feet per acre per year of
industrial wood under natural conditions due to adverse site conditions, and is withdrawn from timber
utilization by law. Crews must include documentation of why the condition is considered
unproductive in the PLOT NOTES. Adverse conditions include sterile soils, dry climate, poor
193
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
drainage, high elevation, steepness, and rockiness. Vegetation, if present, is widely spaced and
scrubby, or tree growth cannot be established. These conditions can be due to forces of nature or
human-caused disturbances.
40 – UNPRODUCTIVE FOREST LAND
Forest land that is incapable of producing 20 cubic feet per acre per year of industrial wood under
natural conditions due to adverse site conditions. Crews must include documentation of why the
condition is considered unproductive in the PLOT NOTES. Adverse conditions include sterile soils,
dry climate, poor drainage, high elevation, steepness, and rockiness. Vegetation, if present, is
widely spaced and scrubby, or tree growth cannot become established. These conditions can be
due to forces of nature or human-caused disturbances.
41 – UNPRODUCTIVE RESERVED FOREST LAND
Publicly-owned forest land that is incapable of producing 20 cubic feet per acre per year of industrial
wood under natural condition due to adverse site conditions, and is withdrawn from timber utilization
by law. Crews must include documentation of why the condition is considered unproductive in the
PLOT NOTES. Adverse conditions include sterile soils, dry climate, poor drainage, high elevation,
steepness, and rockiness. Vegetation, if present, is widely spaced and scrubby, or tree growth
cannot be established. These conditions can be due to forces of nature or human-caused
disturbances.
50 – RESERVED FOREST LAND
Publicly owned forest land that is sufficiently productive to qualify as timberland, but is withdrawn
from timber utilization by law.
52 – URBAN FOREST LAND
Land that, except for its location, would ordinarily be classified as timberland. This land is either
nearly (surrounded on three sides), or completely, surrounded by urban development, whether
commercial, industrial or residential. This land meets all of the criteria for timberland, that is, at least
one acre; capable of producing at least 20 cubic feet per acre per year of industrial wood; is not
developed for some use other than timber production; is not reserved by a public agency. It is
extremely unlikely that such land would be used for timber products on a continuing basis. Such
land may be held for future development, or scheduled for development. (The timber that is present
may be utilized only at the time of development.) The land may be undeveloped due to periodic
flooding, low wet sites, steep slopes, or their proximity to industrial facilities that are unfavorable to
residential development.
Forested areas within city parks are not urban forest land. They may be Other Forest Land if the
requirements for Other Forest Land are met, otherwise, they would be nonforest land. City Parks
cannot be classified as Urban Forest Land as it is currently defined.
CHRISTMAS TREE PLANTATIONS
Christmas tree plantations were classified as forest land during the periodic inventory.
However, Christmas tree plantations are now classified as nonforest land. (See nonforest land
use code 87.)
194
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
NONFOREST LAND
Land that does not support, or has never supported, forests, and lands formerly forested where use for
timber management is precluded by development for other uses (see Nonforest Land definition in Section
2.2). Although there may be some stocking, the critical classification factor is the predominant use being
made of the land. Do not confuse with urban forest land. Also a condition that was previously coded
as nonforest remains nonforest unless stocking is met for accessible forest land or it meets the definition
of another nonforest condition.
Note: NONFOREST LAND WITH or WITHOUT TREES is no longer applied in the Northeast. [Revised
03/10/2006.]
The following are the nonforest land use definitions and codes for regional variable 2.50NE. Use
these codes in conjunction with CONDITION CLASS STATUS 2.
61 – CROPLAND
Land that currently supports agricultural crops including silage and feed grains, bare farm fields
resulting from cultivation or harvest, and maintained orchards and nurseries.
63 – IMPROVED / MAINTAINED PASTURE
Land maintained and used and for grazing (not including grazed cropland). Evidence of
maintenance, besides the degree of grazing, includes condition of fencing, presence of stock ponds,
periodic brush removal, seeding, or mowing. Land that generally has less than 10 percent stocking
in live trees (established seedlings or larger trees), except that occasional large trees with the
obvious function of providing shade for livestock, and small single trees or clusters of hawthorn or
eastern red cedar should be ignored when determining stocking.
65 – IDLE FARMLAND
Former cropland or pasture that has not been tended within the last 2 years and that has less than
10 percent stocking with live trees, (established seedlings or larger trees) regardless of species. A
field that is between crop rotations should not be called idle, however, cropland.
67 – OTHER AGRICULTURE
Other farmland is all nonforest land on a farm excluding cropland, pasture, and idle farmland. It
includes farm lanes, stock pens, and farmsteads. Specify the specific land use in the PLOT NOTES.
69 – WETLANDS
Areas subjected to periodic tidal flooding or other areas where water is present for extended periods
during the growing season and for longer periods during the non-growing season. Water usually
comes from rainfall, snowmelt, a rising water table, groundwater seepage, or incoming tides. Water
may be present on the surface of wetlands for varying periods, as in flooded or ponded wetlands, or
it may simply keep the underlying soils saturated near the surface with no surface water present.
[Tiner] Wetlands include bogs, marshes, salt marshes, swamps, meadows and fens.
Bogs are not always nonforest. Some tree species such as black spruce can adapt to bog
conditions. If the stocking requirement is met, the land is considered forest land. The decision as to
whether the land is productive or unproductive will be made by the field crews.
Swamps are not always nonforest. Some tree species readily adapt to the swamp conditions. If the
stocking requirement is met, the land is considered forest land. The decision of whether the land is
productive or unproductive will be made by the field crews.
73 – RIGHTS - of - WAY
Highways, railroads, airports, pipelines, or power lines.
A canal that qualifies as census or noncensus water is coded as CONDITION CLASS STATUS 3 or
4.
195
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
A driveway adjacent or within a residential area is not considered a R.O.W.
A farm lane adjacent or within cropland, pasture, idle farmland and other agriculture is not
considered a R.O.W.
A rail trail that is part of the "rail banking" program is classified as a R.O.W. The rail banking
program, created by a congressional amendment in 1983 [to the 1968 National Trails System Act],
allows the temporary, though often long-term, use of a disused rail corridor as a public trail while
maintaining the option of reactivating the corridor for rail use. If a rail trail can be documented as
being part of this program, then a rail trail is a R.O.W. If not, it is treated as an inclusion of the
adjacent land use.
75 – MINING and WASTE LAND
Surface mining, gravel pits, dumps, landfills or reclaimed mining areas. Note: Reclaimed mining
areas are not always nonforest. Some trees such as black locust readily adapt to reclaimed areas.
If the stocking requirement is met, the land is considered forest land. The field crew will make the
decision of whether the land is productive or unproductive. Reclaimed mine areas should remain in
this land use until either stocking is met for accessible forest land or another nonforest land use
applies.
77 – DEVELOPED RECREATION SITE
Parks, campgrounds, playing fields, athletic, sports tracks, etc.
79 – INDUSTRIAL / COMMERCIAL LAND
Supply yards, parking lots, shopping centers, factories, etc.
81 – RESIDENTIAL
Multiple family housing – More than one family household per structure, for example, condominiums,
townhouses, row houses and apartment buildings.
Single family housing – One family or person per structure.
85 – OTHER NONFOREST
The use of this land use requires a description in the PLOT NOTES.
87 – CHRISTMAS TREE PLANTATIONS
Active Christmas tree plantation must show signs of annual shearing. Record tree species used in
the plantation in the PLOT NOTES.
The following codes are for “office use” only. These three codes correspond to CONDITION CLASS
STATUS 3, 4 and 5.
91 – CENSUS WATER
92 – NONCENSUS WATER
95 – DENIED/HAZARDOUS
196
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Appendix D. Tally Procedures in the Northeast
This appendix covers items not addressed in the national field guide that are unique to the Northeast data
collection, or not covered in the main text of Sections 0 through 7.
ALTERNATES
During the initial establishment of the 5 Panel Cycle, occasionally it will not be possible to establish a
specified sample plot (SKs 5, 6, 7 or 8) due to inadequate previous plot records. When this happens,
promptly notify your supervisor. If an alternate is warranted, the plot is sent and all office and field copies
of the plot listings are updated to show the change. Once an alternate is selected, the original plot is no
longer in the sample and requires only a notation as to why an alternate was requested. These alternate
plots are not SK 3 Replacement plots and do not require data entry. An SK 3 Replacement plot is
authorized when an SK 2 plot cannot be established due to inadequate previous plot records.
CENSUS WATER
Apply one of the following rules and in the PLOT NOTES specifically identify the river, lake, or other body
of water:
•
If all or any portion of a remeasured plot is determined to be census water due to some change
(physical or definitional) since the previous inventory, the plot is established and delineated.
•
If a new plot’s center (PC at subplot 1) falls on land and portions of the plot falls in census water,
the plot is established and delineated.
•
If a new plot’s center (PC at subplot 1) falls in census water and portions of the plot falls on land,
the plot is established and delineated.
•
If a new plot falls entirely in census water (i.e., all four subplots), an alternate is required.
RESERVED LAND
Do not scribe trees on land that has been classified as reserved unless granted permission.
Lacking such permission, witness the SP, line trees, and PC with other features or landmarks.
The use of scribes and paint are prohibited on plots located in Wilderness areas on National Forests. It is
important to be able to relocate plots, subplots, and trees measured during the inventory. In Wilderness
areas, less visible markings are always appropriate. Detailed, concise sketches and notes will also make
subsequent relocation easier. [INTRA-AGENCY AGREEMENT 05-SU-FIA01]
All accessible forest land that is designated as public ownership requires documented verification as to
whether or not the land use is reserved (see definitions for REGIONAL LAND USE CLASS 32, 33, 41 and
50). If publicly owned forest land is determined to be reserved, this land qualifies as RESERVED
STATUS equals 1.
[Added 12/05/2005.] The following table shows the possible RESERVED STATUS coding for each
OWNER GROUP and REGIONAL LAND USE CLASS combination in the Northeast.
RESERVED STATUS Coding
OWNER GROUP
10
20
30
40
20
0
0
0
0
30
0
0
0
0
< REGIONAL LAND USE CLASS >
31
32
33
40
41
0
1
1
0
1
0
1
1
0
1
0
1
1
0
1
0
0
0
0
0
197
50
1
1
1
0
52
0
0
0
0
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
[Revised 12/05/2005.] State supervisors may be able to provide a list of public lands that may qualify as
reserved. The web based source Wilderness.net lists wilderness areas that may be found on Forest
Service, Fish and Wildlife Service, National Park Service and the Bureau of Land Management.
It is important that all public (federal, state or local) land is documented in the PLOT NOTES when
RESERVED STATUS = 0 or 1. Example:
•
Reserved public forest – Hickory Creek Wilderness Area / Source – J. Smith, ANF – KT 04/19/05
•
Non reserved state forest – Source – S. Jones, PA Bureau of Forestry – KT 04/19/05
DELINATION AND PLOT DIAGRAM RULES
1. A plot diagram is not required where CONDITION CLASS STATUS 2 is the same nonforest
land use for all subplots. If a plot diagram is not attached to the plot record, then a description of
the nonforest condition class is required in the PLOT NOTES. Example: All condition 1 / LU = 61
-- plot falls in cornfield.
2. A plot diagram is required where CONDITION CLASS STATUS 2 is comprised of multiple
nonforest regional land uses on the subplots and the crew can occupy the plot. A "quick-rough"
map and labeling of these multiple nonforest land uses on the plot diagram is required.
Recording the multiple nonforest land uses as separate nonforest condition classes and
delineating associated boundaries is not required. The land use at plot center of subplot 1 is
recorded for the entire plot. See example below.
Boundary
is sketched
only.
LU 84
LU 61
All CC # 1, CCS = 2
3. A plot diagram and delineation is required for plots that have a combination of CONDITION
CLASS STATUS 2 through 5. Changes of condition class statuses, boundaries and other ground
features are drawn and labeled on the plot diagram. All condition classes and associated
boundaries are recorded and delineated. See example on next page.
198
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
CC # 2, CCS = 4
Boundaries
are delineated
between the
CCSs.
LU 91
330
025
002
LU 84
CC # 3
CCS = 5
175
CC # 1, CCS = 2
4. A plot diagram and delineation is required for all plots with CONDITION CLASS STATUS 1.
Changes of condition class statuses, boundaries and other ground features are drawn and
labeled on the plot diagram. All condition classes and associated boundaries are recorded and
delineated where multiple CONDITION CLASS STATUSES occur on the subplot. See example
below. There are 2 nonforest land uses at subplot 3. Delineation is not required between these
2 nonforest land uses because the entire subplot is CONDITION CLASS STATUS 2.
CONDITION CLASS NUMBER 1 is assigned to subplot 3. The second nonforest land use is
drawn on the plot diagram only.
CC # 2, CCS = 1
Boundaries
are delineated
between the
CCSs.
LU 20
330
025
LU 61
LU 84
CC # 1, CCS = 2
199
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Note: In the situations where a plot diagram is required, the information from the diagram is helpful for
remeasurement (i.e., relocating a plot) and to clarify "office" questions about the data. As with PLOT
NOTES the value of a good plot diagram cannot be overemphasized.
RECONCILING THE PREVIOUS TALLY
During this inventory on SAMPLE KIND 6 and 7, the trees that fall on subplot 1 are the only trees that will
be reconciled to the previous inventory. On SAMPLE KIND 2 and 5, the trees that fall on all 4 subplots
will be reconciled to the previous inventory. Only trees 5 inches DBH and greater within the 24.0 ft
subplot radius will be tallied, or reconciled, as part of the regular tally procedure. All trees that are further
than 24.0 ft away from subplot center will be ignored or reconciled, even if they were tally trees at the last
occasion. On SAMPLE KIND 2 or 5-P3 (former FHM plots), the saplings that fall on all 4 microplots will be
reconciled to the previous annual inventory.
On remeasure plots that were previously classified as nonforest, if PC at subplot 1 is still nonforest,
record any forest boundaries within the 24.0 ft subplot radius. Only trees 5 inches DBH and greater on
forested subplots will be tallied. As well as trees 1 inch DBH or greater on forested microplots will be
tallied. Give all trees a tree history of 22.
The following examples are common, simple situations. A correct reconciliation may be time demanding
and complex. However, this is a critical part of the inventory. Training will be provided. Crews are to
direct any questions to supervisors as soon as possible.
Examples:
1. The first tree to be tallied at subplot 1 is now an ingrowth, dead ingrowth, or previously missed
tree. Assign the first available tree number and record the appropriate current data. If there were
35 trees on this subplot the last time, assign this tree number 036.
The next tree tallied was tree number 001 at the last inventory. Since trees are no longer being
renumbered each inventory, previous tally tree number 001 is current tree number 001.
2. The first tree on the old plot record was a 24-inch DBH sugar maple, followed by an 8-inch DBH
beech. The beech is present and is the first live tree starting from an azimuth of 001. There is no
evidence of the sugar maple. Check the area to the plot radius limit to see if there is a stump of
the maple. Perhaps there is -- perhaps not. The maple was, and still is, tree number 001. The
beech tree is tree number 002.
PREVIOUS TREE HISTORY CODES
Tree history codes used during the previous inventory differ slightly from history codes that we currently
use. If the plot has a computer generated reconciliation form, use it to reconcile the tally on the plot. The
codes shown on the computer generated reconciliation form have been adjusted to align the old tree
history codes with the current codes. If a reconciliation form is not available, use the plot record or
printout from the last occasion to reconcile the tally. In those situations when it becomes necessary to
refer to the old plot records, remember that there may be some minor differences in the history codes.
PREVIOUS TREES THAT ARE NOT ON THE HISTORY FILE
Occasionally the electronic history files used in the portable data recorder (PDR) tally program are
incorrect. These errors must be detected and corrected. To do so, all remeasured plots must be
reconciled to the printed or handwritten plot records from the last occasion. The history files that are
transferred to the data recorder cannot be relied upon to be complete. A check of the current tally against
the previous tally must be completed for each plot. Whenever a discrepancy is found between the
electronic history file and the generated reconciliation form, contact Newtown Square.
If you identify a tree that was tallied correctly at the last occasion but is not contained in the electronic plot
history file, enter the previous TREE NUMBER that is on the plot record and assign the appropriate TREE
HISTORY. You will also need to enter the PREVIOUS DBH, PREVIOUS TREE CLASS /
200
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
MERCHANTABILITY CLASS, and PREVIOUS LAND USE. This information is also on the previous plot
record. This procedure may vary depending on the PDR tally program. Contact Newtown Square for
current procedures if they are unknown to you.
SPECIAL INSTRUCTIONS FOR THE OHIO INVENTORY – SAMPLE KIND 8
During the last periodic Ohio inventory the majority of the plots established were a 10-point design. 37.5
BAF prisms were used to sample the trees on each of the ten points. For the new inventory, the national
4-subplot design will overlay this 10-point design. In order to establish a growth, removal and
mortality estimates; a partial remeasurement on five of the ten points will be completed during the
first 5-year cycle of the Annual Forest Inventory. The previous “prism” points to be reconciled are 1,
2, 6, 7 and 8. (See Figure 1)
Figure 1: 10-point with 4-subplot overlay
3
10
4
2
360° 70.0' 5
9
1
240°
120°
6
8
7
On the plot record and data recorder “prism” points 1, 2, 6, 7 and 8 will be renumbered as 5, 6, 7, 8 and 9.
The national 24 ft fixed radius subplots will continue to be numbered 1 through 4. (See Figure 2)
Figure 2: New numbers for prism points
Subplot 2
P6
360° 70.0' 120.0'
Subplot 1
P5
240°
120°
P9
180°
P7
P8
Subplot 4
201
Subplot 3
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
The following tree variables will be collected on the “prism” points:
•
•
•
•
•
•
•
•
•
•
TREE RECORD NUMBER
SPECIES
TREE HISTORY
DBH
TREE CONDITION CLASS
TREE CLASS
MERCHANTABILITY CLASS
PREVIOUS DBH
PREVIOUS TREE CLASS / MERCHANTABILITY CLASS
NOTES
In addition, ingrowth (trees 5-in and greater at DBH) will be measured on a microplot (6.8 ft radius) located
at point center (PC). Even though point 5 is concentric with subplot 1, it will be necessary to complete a
separate tally for these ingrowth trees. The tree variables on the “ingrowth” microplots will be the same as
the “prism” points less the previous information. (See Appendix H, Ohio Tally Guide).
Note: Even though you are not recording tree grade, lengths and culls, these variables need
consideration prior to assigning tree class and merchantability class.
Crews will be supplied with a printout of the previous tally trees to be reconciled from these points. Since
these were prism tallies, it is important to realize that “prism” trees may be located 70 ft or more from
PC depending on the DBH and percent slope. E.g., A tree with a 40-in DBH, no slope, has a limiting
“horizontal” distance of 56.8 ft.; same tree, 60% slope, has a limiting “slope” distance of 66.2 ft. Since the
tally was dependent on the limiting distance, large diameter trees could occur on multiple points. To
reconcile “prism” points, the horizontal distance is measured from PC to the center of the tree at
DBH.
On the last occasion crews tallied the points in order from one to ten. Each point was located 70 ft and
360°, 120°, 240°, or 300° from the last point. In addition all ten points were located in the same condition.
The condition was defined at plot center of point 1. Points that fell in contrasting conditions were rotated
from the highest non-rotated point.
For example, point 1 through 10 fell in forest land except for point 7 (P8). The first location to establish
this rotated point would be 70 ft at 360° from point 10, then at 240°, and finally at 300°. (If point 10 did not
yield a location, then the same procedure was followed at point 9 at 240°, etc. This procedure was
continued until the point could be established in the same condition as point 1.) The point was then
renumbered as point 17 (P8) to indicate the rotation, and the new point location was documented on the
plot diagram. (See Figure 3)
202
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Figure 3: "Old" point rotation procedure
Rotated Point
P8 17
70.0'
3
10
4
P6 2
360°
9
5
P5 1
240°
P9 8
Forest
120°
P7 6
P8 7
Nonforest
On this occasion complete the “regular” tally at subplot 1, and then complete the “partial” tally of point 5.
The previous trees from “prism” point 5 within the 24 ft radius of PC at subplot 1 will require a second tally
to complete the reconciliation. It is important that all “like” tree variables match between subplot 1 and
point 5. The remainder of the subplots and “prism” points should be completed as field conditions
warrant. I.e., A crew may find it more efficient to complete subplot 2 before completing “prism” point 6 or
vice versa.
Plots where PC was nonforest on the last occasion and is still nonforest at PC, nothing needs to be
done with the prism points. Install the current 4 subplot design.
Plots where PC was nonforest on the last occasion and is now forest at PC, then all 5 prism points
requires a tally of the 6.8 ft microplot. Tree history 22 (live or dead tree, that was on nonforest land, and is
now accessible forest land) is used for these trees. Installation of the current 4 subplot design is also
completed.
Since on the last occasion PC determined the land use for the entire plot, any prism point that fell outside
a nonforest land use would have been rotated to match the same land use at PC. For nonforest plots
these rotated prism points were never established. To locate these rotated prism points today, use the old
10-point plot design and make a determination where these rotated points would have been placed based
on any markings on the old plot record, old photography and current ground conditions. This will not be
easy and could be time consuming depending on the situation. If it is impossible to determine where the
rotated points are to be located due to indistinct boundaries, use the standard prism point locations and
proceed with the tally.
For example, on the last occasion PC fell in a R.O.W. The entire plot was called nonforest (land use 73).
Even though the prism points were not established, 2 out of the 10 prism points fell in forest land and
would have been rotated into the nonforest land use. These points would have been 17 and 18 rotated
from point 10. (See Figure 3a)
203
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Figure 3a: PC was nonforest on the last
occasion with “rotated” point locations
Forest
P8 17
Rotated Points
70.0'
P9 18
3
70.0'
10
4
P6 2
360°
9
5
R.O.W
P5 1
240°
120°
P7 6
P9 8
P8 7
Forest
Today, the R.O.W is no longer maintained and has reverted back to forest. Therefore, prism points
renumbered as P5, P6, P7, P8 and P9 must be visited. P5, P6 and P7 are still at the standard location of
the 10-point plot design, but P8 and P9 are not. These 2 points are at the rotated position as illustrated in
Figure 3a and 3b.
Figure 3b: PC was nonforest on the last
occasion and is now forest due to land use
change.
Forest
P8 17
Rotated Points
70.0'
P9 18
3
70.0'
10
4
P6 2
360°
9
5
P5 1
240°
P9 8
P8 7
Forest
204
120°
P7 6
Forest –
Reverted
R.O.W.
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
SPECIAL INSTRUCTION FOR THE NEW YORK INVENTORY
During the last periodic New York inventory the majority of the plots established were a 10-point design.
After the 10-point reconciliation was completed, a 1/5-acre overlay was completed at point 1. (See Figure
4)
Figure D4: 10-point prism plot with 1/5 acre overlay (52.7 ft
radius). Each point is located at 70 feet from another point at
360, 120, 240 or 300 degrees.
3
10
4
2
9
5
1
8
6
7
On the last occasion only minimal tree data was collected on the overlay. These variables were the
following:
•
•
•
•
•
•
•
•
•
TREE RECORD NUMBER
SPECIES
HORIZONTAL DISTANCE
AZIMUTH
DBH
TREE CONDITION CLASS
TREE CLASS
MERCHANTIBILITY CLASS
NOTES
On this occasion only the trees from the 1/5-acre overlay are reconciled at subplot 1. Crews will be
supplied with a history data of the previous tally trees to be reconciled from the 1/5-acre overlay within
subplot 1. All plot variables are collected. Additional tally from the old 10-point design will be ignored.
However, this information will be attached to the plot record and may aid you in relocating the plot. (See
Figure 5)
205
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Figure D5: 10-point plot with 1/5 overlay (52.7 ft radius) and
current 4-subplot overlay. This plot represents current SK 7.
3
10
4
2
9
5
1
8
6
7
OTHER PREVIOUS PLOT DESIGNS – Additional figures 6 through 8 are to aid in relocating remeasure
plots.
Figure D6: Old 1/5 acre (52.7 ft radius) with prism points and
new 4 subplot overlay. The prism points were at the cardinal
points located 98.4 feet from PC. This plot represents current
SK 6.
206
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Figure D7: Old 1/5 acre (52.7 ft radius) and new 4 subplot
overlay. This plot represents current SK 7.
Figure D8: Old 10-point prism plot and new 4 subplot overlay.
This plot represents current SK 8.
3
10
4
2
9
5
1
8
6
7
207
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
TWO ALTERNATING STRIPS – Figure 7b, Section 2.4
On the following pages are 4 examples on how to apply” Exception Rule 7b” for two alternating strips of
forest and nonforest between two qualifying areas of nonforest land and forest land (From Section 2.4).
Note: Not all plot scenarios are shown.
From Figure 7b, Section 2.4
Example 1
N
NF
2
1
4
3
PC of subplot 1 falls in the NF strip. Subplot 1 is classified as NF and the
adjacent F strip is also classified as NF. Subplot 2 is classified as all NF (this
boundary does not require delineation). Subplot 3 is classified as F. Subplot 4
is classified as NF/F (a boundary is delineated between the NF and F).
208
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Example 2
2
N
1
3
4
F
PC of subplot 1 falls in the F strip. Subplot 1 is classified as F and the
adjacent NF strip is also classified as F. Subplot 2 is classified as all NF.
Subplot 3 and 4 are classified as F.
Example 3
N
2
1
F
4
3
PC of subplot 1 falls in the qualifying F. All the subplots are classified as F.
209
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Example 4
N
NF
4
2
1
3
PC of subplot 1 falls in the qualifying NF. All the subplots are classified as NF.
“SWITCHBACK” RULE – Figure 5, Section 2.4
The following illustrations show examples of how to apply the “switchback” rule from Section 2.4, Figure 5
in the Northeast. The “switchback” rule if properly applied reduces forest fragmentation caused by
R.O.W., other “developed” conditions and noncensus linear water features that are less than 120.0 feet
wide that exist within accessible forest land.
In the illustration below a forested strip is at least 30.0 feet but less than 120.0 feet wide and is also 1
acre in size. This strip is treated as part of the greater accessible forest land condition. Note: These
strips are not delineated as a separate condition, but are treated as an inclusion of the greater forest
condition.
Forest
>= 1 acre and 120.0 ft wide
Improved road, R.O.W., development or
noncensus water < 120.0 ft wide
Forest strip
>= 30.0 ft and < 120.0 ft and >= 1 acre
Improved road, R.O.W., development or
noncensus water < 120.0 ft wide
Forest
>= 1 acre and 120.0 ft wide
210
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
In this illustration the plot falls in a parcel of forest represented by sub-parcels Q1 through Q4. Each subparcel meets the minimum specifications for accessible forest land. Applying the “switchback” rule,
subplot 1 can be classified as accessible forest land. Note that “120.0 feet and less than 90 degree” rule
(see Section 2.2, Figure 2) does not apply to subplot 1 since the sub-parcels Q2, Q3 and Q4 are
accessible forestland. At subplot 4, the 2nd condition created by the R.O.W. is recorded and delineated.
Q2
120.
0 ft
Q1
120
.0 ft
R.O.W. < 120.0 feet in width
Q4
Q3
In this next illustration the plot falls in a parcel of forest represented by sub-parcels Q1, Q3 and Q4. Q2 is
nonforest. Sub-parcels Q1, Q3 and Q4 meet the minimum specifications for accessible forest land. Subparcel Q2 qualifies as nonforest land. Applying the “switchback” rule, subplot 1 can still be classified as
accessible forest land. Note that “120.0 feet and less than 90 degree” rule does not apply to subplot 1
since the sub-parcel Q3 and Q4 are accessible forestland. Subplot 2 is classified as nonforest. At
subplot 4, the 3rd condition created by the R.O.W. is recorded and delineated.
Q2
120.
0 ft
Q1
120
.0 ft
R.O.W. < 120.0 feet in width
Q4
Q4
Q3
211
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
In this illustration the plot falls in a parcel of forest represented by sub-parcel Q1 and Q3. Q2 and Q4 are
nonforest. Sub-parcels Q1 and Q3 meet the minimum specifications for accessible forest land. Subparcel Q2 and Q4 qualifies as nonforest land. Subplots 1 through 3 are classified as nonforest. Subplot
4 is classified as forest and the 3rd condition created by the R.O.W. is recorded and delineated.
Q2
120.
0 ft
Q1
120
.0 ft
R.O.W. < 120.0 feet in width
Q4
Q3
In this final illustration the plot falls in a parcel of forest represented by sub-parcel Q1 and Q4. Q2 and Q3
are nonforest. Sub-parcels Q1 and Q4 meet the minimum specifications for accessible forest land. Note
that “120.0 feet and less than 90 degree” rule now applies to subplot 1 since the sub-parcel Q2 and Q3
are nonforest. Subplot 1, 2 and 4 are classified as nonforest. At subplot 4 the entire plot is classified as a
single nonforest land use since delineation is not required between nonforest land uses. Subplot 3 is
classified as forest.
Q2
120.
0 ft
Q1
120
.0 ft
R.O.W. < 120.0 feet in width
Q4
Q4
Q3
212
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
ADDITIONAL HORIZONTAL DISTANCE MEASUREMENT PROCEDURES
The following paragraphs are additional instructions on horizontal distance measurement for trees that
lean, windthrown or on steep terrain.
A leaning tree is determined to be "in" or "out" of a plot radius by measuring the horizontal distance from
plot center, to the center of the tree at the base. The direction that the tree leans is of no consequence.
For a down and windthrown tree measure the horizontal distance to the spot where the center of the tree
would have been if the tree was still standing; i.e., measure the distance to the center of the stump, or
ground cavity See illustration below.
distance of
fallen tree
center stake
center of stump hole
A tree on steep terrain, occasionally, cannot be accurately measured by taking a direct horizontal
distance. When this happens, the slope distance (measured parallel to the ground) and the percent slope
(measured with a clinometer and this too is parallel to the ground) from subplot center to the tree will be
needed to calculate the horizontal distance. See Figure 9. The formula for calculating the horizontal
distance is as follows:
measure slope distance to tree
horizontal distance to tree
=
100 ft slope distance
100 ft horizontal distance
For example, a tree has a slope distance of 23.9 ft and the slope is 48 %. Using the Slope Correction
table in Appendix E you find that the correction for 100 ft with 48 % slope is 10.9 ft.
All that’s left is to solve the equation:
23.9 ft
horizontal distance to tree
=
110.9 ft
100 ft
Solve for the horizontal distance, HD = 21.6 ft.
Note: If TALLY is available, the POPUP MENU contains a horizontal distance utility. For this utility enter
the measured slope distance and the percent slope and the utility calculates a horizontal distance.
213
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
4.5’
Figure 9: A slope distance (dashed line) is measured
parallel to the ground from the subplot center to the
center of the tree and percent slope is measured along
this dashed line (slope distance).
There is an alternative method to measure the slope distance and percent slope as shown in Figure 10.
Either measurement method will yield a horizontal distance when applied to the formula on the previous
page or entered into the horizontal distance utility in TALLY.
4.5’
Figure 10: A slope distance (dashed line) is measured
from the subplot center to the center of the tree and
percent slope is measured along the dashed line (slope
distance.)
214
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
HORIZONTAL DISTANCE – THEN AND NOW
What should be recorded for the HORIZONTAL DISTANCE on a remeasured subplot or microplot?
HORIZONTAL DISTANCE has 2 functions: 1) It determines whether a tree is in or out, and 2) relocates a
tree/sapling for remeasurement.
Subplot
If a previous tree is located on the "inner" ring of the subplot (i.e., 00.1 to 23.0 ft), then only change the
previous recorded distance if it is does not meet the current 1.0 ft tolerance. Example, if the previous
distance was recorded as 15.2 and the current distance is now 16.0, the previous value is satisfactory.
There is no need to change this value unless the previous distance causes current on the ground
confusion like trees located in a clump. In these situations it makes sense to change this distance even if
the previous distance is within tolerance.
If a previous tree is located on the "outer" ring of the subplot (i.e., 23.1 to 24.0 ft), then only change the
previous distance if it is greater than the current 0.2 ft tolerance. A tree that was previously recorded as
23.9 ft or 24.0 ft should be examined closely. If this tree is now recorded as 24.1 or 24.2, then the tree is
considered out. (Note: Crews should be careful when re-establishing subplots where the dowel or pin is
gone so that the cause for a tree to be out was not due to subplot re-establishment.) Crews working on
extreme slopes should examine all trees on the outer ring to verify that they are indeed in or now out. On
a similar note, trees that were determined to be out (i.e. "x" trees) on the last occasion should be
reexamined on this occasion to verify that they are indeed out.
Microplot
If a previous sapling's recorded distance is within the 0.2 ft tolerance, then no change to distance is
required. A sapling that was previously recorded as 6.7 ft or 6.8 ft should be examined closely. If this
sapling is now recorded as 6.9 or 7.0, then the sapling is considered out. (Note: Crews should be careful
when re-establishing subplot and microplots where the dowel or pin is gone so that the cause for a
sapling to be out was not due to subplot or microplot re-establishment.) Saplings that were determined to
be out on the last occasion should be reexamined on this occasion to verify that they are indeed out.
Note: Saplings should not be given an “x” when determined to be outside the 6.8 ft radius since these
saplings may eventually become tallied trees.
What about azimuth? The same logic applies. Change only those azimuths that exceed the current five
degree tolerance unless the previous azimuth causes current on the ground confusion like trees located
in a clump. It makes sense to change these azimuths even if the previous azimuths are within tolerance
Finally, the QA staff will not to deduct points on a QC report unless the value exceeds the tolerance as
described in the field guide. Note to crews: If the QA staff determines a tree to be in or out, then points
will be deducted from QC report. This usually results in an unsatisfactory report. However, if the QA staff
determines it is unreasonable to fail a plot based on a single missed or overlooked tree due to plot
conditions, then a plot can still qualify as satisfactory.
215
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
216
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Appendix E. Tables and Charts
HARDWOOD TREE GRADES
GRADE 1 GRADE 2
GRADING FACTORS
Butt 16
Butt 16
Length of grading zone (ft)
a
Length of grading section (ft)
Best 12
Best 12
b
13
Minimum DBH (in)
16
Minimum DIB at the top of the
b
c
13 16 20
11 12
grading section (in)
d
Clear cuttings on 3rd best face
minimum length (ft)
7 5 3
3 3
number on face (max)
2
2 3
yield in face length (min)*
5/6
4/6
Cull deduction, including crook
and sweep but excluding shake,
e
9
9
maximum w/in grading section
(%)
GRADE 3
Butt 16
Best 12
11
8
2
unlimited
3/6
50
a
Whenever a 14- or 16-ft section of the butt log is better than the best 12-ft
section, the grade of the longer section will become the grade of the tree.
This longer section, when used, is the basis for determing the grading factors, such as diameter and cull deduction.
b
In basswood and ash, DIB at the top of the grading section may be 12-in
and DBH may be 15-in.
c
Grade 2 trees can be 10-in DIB at the top of the grading section if
otherwise meeting suface requirements for small grade 1's.
d
A clear cutting is a portion of a face free of defects, extending the width of
the face. A face is one-fourth of the surface of the grading section
as divided lengthwise.
e
15% crook and sweep, or 40% total cull deduction are permitted in grade 2
if size and surface of grading section qualify as grade 1. If rot shortens
the required clear cuttings to the extent of dropping the butt log to grade 2,
do not drop the tree's grade to 3 unless the cull deduction for rot is
greater than 40%.
*Minimum Yield in Face Length
Grade 1 Min. Grade 2 Min. Grade 3 Min.
Face Length
Yield
Yield
Yield
12-ft
10-ft
8-ft
6-ft
14-ft
11.7-ft
9.3-ft
7-ft
16-ft
13.3-ft
10.7-ft
8-ft
217
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
LOG SURFACE ABNORMALITIES THAT ARE DEFECTS IN HARDWOOD LOGS
Adventitious bud cluster
Bulge, butt or stem
Bump
Burl
Butt scar
Canker
Conk
Flute
Hole extending into the bole
Embedded metal
Limb
Knot
Knot overgrowth
Overgrowth following insect damage
or bird peck1
Seam, crack, split2
Wound extending into the bole
1
There must be four bird pecks within a square foot to affect the tree grade. First, determine the tree
grade without the bird pecks. If the tree grade is determined to be 1 or 2, then down grade the tree by one
grade. If the tree graded out to be a 3 or 4 without the bird pecks, then ignore them as defects and record
the initial tree grade.
2
A straight seam, crack, or split can be placed on the edge of one face and ignored. This fixes the
location of all other faces and defects.
TIE AND TIMBER GRADE 4
GRADING FACTORS
SPECIFICATIONS
Position in tree
Butts and uppers
Scaling diameter (in)
8-in DIB and larger
Length, w/o trim (ft)
12-ft and longer
Clear cuttings
No requirements (not graded on cutting basis)
Maximum sweep
allowance
One-fourth DIB of small end for half logs, and
one-half DIB for logs 16-ft long
Sound surface defects -
Single knots
Whorled knots
Knots
Unsound surface
defects b
Any number, if none has an average collara
diameter that is more than one-third of the log
diameter at the point of occurrence.
Any number, provided the sum of the collar
diameters does not exceed one-third the log
diameter at the point of occurrence.
Any number not exceeding knot specifications, if they do not extend more than 3-in into
the contained tie or timber.
Any number and size, if they do not extend
into contained tie or timber. If they extend
into contained tie or timber, they shall not
exceed size, number, and depth of limits for
sound defects.
a
Knot collar is the average of the vertical and horizontal diameters of the
limb, or knot swelling, as measured flush with the surface of the log.
b
Interior defects are not visible in standing trees. They are considered in
grading cut logs. No interior defects are permitted except one shake not
more than one-third the width of the contained tie or timber, and one
split not more than 5-in long.
Note: Knot “collar” diameter rules in the above table do not apply to knots on the softwood grading tables.
218
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
GRADING FACTORS
Minimum DBH (in)
Maximum weevil injury
in butt 16-ft section
(number)
Minimum face
requirements on butt
16-ft section
Maximum sweep or
crook in butt 16-ft
section (%)
Maximum total scaling
deduction in 16-ft
section (%)
EASTERN WHITE PINE TREE GRADES
GRADE 2
GRADE 3
GRADE 1
9
9
9
GRADE 4
9
None
None
2 Injuries
No limit
Two full length or
four 50% length
good faces1. (In
addition, knots
on balance of
faces shall not
exceed size
limitations for
Grade 2
sections.)
NO GOOD
FACES
REQUIRED.
Maximum diameter of knots on
3 best faces:
SOUND RED
KNOTS not to
exceed 1/6 of
scaling diameter
or 3-in
maximum2.
DEAD OR
BLACK KNOTS,
in-cluding overgrown knots, not
to exceed 1/12
scaling diameter
and 1-1/2-in
maximum.
NO GOOD
FACES
REQUIRED.
Maximum diameter of knots on
3 best faces:
SOUND RED
KNOTS not to
exceed 1/3 of
scaling diameter
of 5-in
maximum2.
DEAD OR
BLACK KNOTS,
in-cluding overgrown knots, not
to exceed 1/6
scaling dia-meter
and 2-1/2-in
maximum.
Includes all trees
not qualifying for
Grade 3 or better
and judged to
have at least 1/3
of their gross
volume in sound
wood suitable for
manufacture into
standard lumber.
20
30
40
No limit
50
50
50
No limit
After the tentative grade of the section is established from face examination, the section
will be reduced one grade whenever the following defects are evident3:
CONKS, PUNK KNOTS AND PINE BORER DAMAGE ON THE SURFACE OF THE SECTION
Degrade one grade if present on one face.
Degrade two grades if present on two faces.
Degrade three grades if present on three to four faces.
If the final grade of the grading section is 1, 2 or 3, examine the tree for weevil injuries in
the merchantable stem above 16-ft. If the total apparent weevil damage exceeds 3, degrade the tree grade one below the section grade3. Otherwise the tree grade is the same
as the final section grade.
1
2
3
Trees under 16-in DBH require four full length good faces.
Scaling diameter is estimated at the top of the 16-ft grading section.
No tree will be designated below Grade 4 unless net tree scale is less than one-third of
gross tree scale.
219
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
WHITE PINE COLLAR DIAMETER LIMITS FOR RED AND BLACK KNOTS
GRADE 1 AND 2
SCALING
DIAMETER
BLACK KNOTS
RED KNOTS
th
th
1/6
1/12
(D.I.B. inches)
7
8
9
10
11
12
13
14
15
16
17
18
7/12"
2/3"
3/4"
5/6"
11/12"
1"
1 - 1/12"
1 - 1/6"
1 - 1/4"
1 - 1/3"
1 - 5/12"
1 - 1/2" MAX
GRADE 3
BLACK KNOTS
RED KNOTS
th
rd
1/6
1/3
1 - 1/6"
1 - 1/3"
1 - 1/2"
1 - 2/3"
1 - 5/6"
2"
2 - 1/6"
2 - 1/3"
2 - 1/2"
2 - 2/3"
2 - 5/6"
3 MAX"
1 - 1/6"
1 - 1/3"
1 - 1/2"
1 - 2/3"
1 - 5/6"
2"
2 - 1/6"
2 - 1/3"
2 - 1/2" MAX
2 - 1/3"
2 - 2/3"
3"
3 - 1/3"
3 - 2/3"
4"
4 - 1/3"
4 - 2/3"
5" MAX
Red knots – Visible branches, stubs or sockets that are from living branches or branches that have
recently died. They are intergrown with the surrounding wood and contain no rot.
Dead or black knots – Visible branches, stubs or sockets that do not conform to the definition of red
knots.
Overgrown knots – Identified by a distinctive circular/elliptical pattern in the bark and are treated the same
as dead knots.
Average diameter of red and black knots on white pine – Measured at the point where the limb would
normally be trimmed from the main stem. For red knots measure only the heartwood portion of the knot.
For black knots measure the whole limb.
The following tree grading table is based on log grades. Tree grades have never been developed for
these softwood species.
SPRUCE, FIR, CEDAR, TAMARACK AND HEMLOCK
Minimum Merchantability Specifications for Grade 1
DIB (small
end of log)
6" - 12"
13" +
Length (2-ft
multiples
Total
w/o trim) Deduction
12' - 16'
12' - 16'
Sweep
Permitted
50%
50%
Other Requirements*
25%
Sound knots not over 2" in
diameter permitted. Shake
permitted up to 20% of gross
scale if not combined with
other serious defect.
25%
Sound knots not over 3" in
diameter permitted. Shake
permitted up to 20% of gross
scale if not combined with
other serious defect.
* One branch or sound knot that exceeds the diameter limitations is permitted to meet Grade 1
specifications. This is a Northeast allowance. Sound knots are measured at the point where the limb
would normally be trimmed from the main stem.
Note: Shake is not visible on standing trees and cannot be used as grading criteria.
220
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
SOUTHERN PINE TREE GRADES
(All pines except White Pine.)
GRADE 1
GRADE 2
FACE LENGTH
16 ft grading
3 or 4 clear faces 1 or 2 clear faces
section
GRADE 3
No clear faces
After the tentative grade is established, the tree will be reduced one
grade for each of the following:
Sweep - Degrade any tentative Grade 1 or 2 tree one grade
if sweep in the lower 12-ft of the grading section
amounts to 3 or more inches and equals or exceeds
one-fourth the DBH.
Heart rot - Degrade any tentative Grade 1 or 2 tree one grade
if conks, punk knots, or other evidence of advanced
heart rot is found anywhere on the tree stem.
Note - No tree can be degraded below Grade 3, provided
the total scaling deductions for sweep and/or rot do
not exceed two-thirds the gross scale of the tree.
Trees with total scaling deductions in excess of twothirds are classified as cull (Grade 5).
A face is one-fourth the circumference of the 16-ft grading section and extends the full length of the grading section. Clear faces are those free from
knots measuring more than 1/2-in in diameter, overgrown knots of any size,
and holes more than 1/4-in in diameter. Faces may be rotated, if necessary,
to obtain the maximum number of clear faces on the grading section.
Note: Knot diameter is measured where the branch would normally be trimmed. Apply measuring rules
for white pine sound and black knots.
221
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
PERCENT OF CUBIC-FOOT CULL VOLUME FOR
ALL TREES
BY 4-FT SECTIONS & LOCATION IN THE TREE
LENGTH
1ST 2ND 3RD 4TH 5TH 6TH 7TH 8TH 9TH
(FT)
57 43
8
42 32 26
12
30 26 23 21
16
26 23 21 19 11
20
24 21 18 17 10 10
24
21 19 17 16 10
9
8
28
20 18 16 14 10
8
7
7
32
19 16 14 13
9
8
8
7
6
36
17 15 13 12
9
8
7
7
6
40
16 14 12 11
9
7
7
7
6
44
15 13 12 10
8
7
7
6
6
48
14 12 11
9
8
7
6
6
6
52
13 11 10
9
8
6
6
6
6
56
12 11 10
9
7
6
6
6
6
60
11 10
9
9
7
6
6
6
5
64
10 10
9
8
6
6
6
5
5
68
10
9
8
8
6
6
6
5
5
72
10TH11TH12TH13TH14TH15TH16TH17TH18TH
40
44
48
52
56
60
64
68
72
6
6
6
6
6
5
5
5
5
5
5
5
5
5
5
5
4
5
5
5
5
5
5
4
5
5
5
5
4
4
222
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
PERCENT OF BOARD-FOOT CULL OF
HARDWOOD SAWTIMBER
BY 4-FT SECTIONS & LOCATION IN THE TREE
LOG (FT) 1ST 2ND 3RD 4TH 5TH 6TH 7TH 8TH
1
(16)
1-1/2 (24)
2
(32)
2-1/2 (40)
3
(48)
3-1/2 (56)
4
(64)
29
19
15
12
12
10
9
26
18
14
12
10
10
9
24
16
13
11
10
9
9
21
16
13
11
9
9
8
16
12
10
9
9
8
15
12
10
9
8
7
11
9
8
8
7
10
9
7
7
7
9TH 10TH 11TH 12TH 13TH 14TH 15TH 16TH
2-1/2 (40)
3
(48)
3-1/2 (56)
4
(64)
8
7
7
6
8
7
6
6
6
5
5
5
5
5
4
4
3
4
3
3
PERCENT OF BOARD-FOOT CULL OF
SOFTWOOD SAWTIMBER
BY 4-FT SECTIONS & LOCATION IN THE TREE
LOG (FT) 1ST 2ND 3RD 4TH 5TH 6TH 7TH 8TH
1
(16)
1-1/2 (24)
2
(32)
2-1/2 (40)
3
(48)
3-1/2 (56)
4
(64)
33
26
21
19
16
13
10
27
20
17
15
13
12
9
21
16
14
12
11
10
9
19
15
12
10
10
9
8
12
10
9
8
7
7
11
9
8
7
7
7
9
7
7
6
6
8
7
6
6
6
9TH 10TH 11TH 12TH 13TH 14TH 15TH 16TH
2-1/2 (40)
3
(48)
3-1/2 (56)
4
(64)
7
6
6
6
6
6
5
5
5
5
5
5
5
5
223
5
5
4
4
4
4
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
224
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
HOW TO DETERMINE THE LENGTH OF A SIDE WHEN THE INTERIOR ANGLE IS KNOWN
(SOLVING FOR RIGHT TRIANGLES)
Many times it will be easier to measure along the edge of a potential contrasting condition than across.
The following steps and table can be used to determine when the width across an interior corner angle
becomes 120 ft wide.
1.
Determine interior angle of corner.
2.
Refer to table below to find limiting distance along edge of condition.
Interior
Angle of
Corner
88
86
84
82
80
78
76
74
72
70
68
66
64
62
60
Interior
Angle of
Corner
58
56
54
52
50
48
46
44
42
40
38
36
34
32
30
Limiting
Distance
(FT)
86.4
88.0
89.7
91.5
93.3
95.3
97.5
99.7
102.1
104.6
107.3
110.2
113.2
116.5
120.0
Limiting
Distance
(FT)
123.8
127.8
132.2
136.9
142.0
147.5
153.6
160.2
167.4
175.4
184.3
194.2
205.2
217.7
231.8
The following formula was used to create the preceding table.
Limiting Distance = 60 / SIN (Interior Angle x .5)
See example on next page.
225
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
EXAMPLE
Bisected interior angle
forms two right triangles.
60 ft
Interior corner
angle is 40°.
60 ft
If subplot falls here, no boundary
and area inside the corner is an inclusion
of the surrounding condition.
If subplot falls here, there is
(At 175 ft the width across the interior angle is 120 ft..)
226
a boundary and the contrasting
condition requires delineation.
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
FOREST LAND PRODUCTIVITY GUIDE
The table below may be used by field crews to assist in the determination of unproductive forest land; that
is, land on which the potential productivity is less than 20 cubic feet of industrial wood per acre, per year.
From an increment boring, determine the age class of a tree that is located on the site in question. For
example, a 27 year old black spruce in the 20 year age class must be at least 8 feet tall if the site is to be
considered as being productive. Sample trees must be representative of the site. The factors of
drainage, soils, elevation, and exposure must also be considered.
Total height in feet at upper limit of the unproductive site class
AGE CLASS
20
BLACK
SPRUCE
HEIGHT
8
BLACK ASH
HEIGHT
12
RED MAPLE
HEIGHT
10
CHESTNUT
OAK
HEIGHT
12
30
13
21
17
21
40
19
29
24
29
50
25
34
32
34
60
30
39
37
39
70
33
45
43
45
80
39
50
49
50
90
41
53
53
52
100
43
57
57
56
110
47
60
60
57
120
50
60
61
58
130
51
61
61
59
140
52
62
62
60
150
53
63
62
--
160
--
64
63
--
170
--
65
63
--
180
--
65
63
--
Boring or drilling on plots located in Wilderness areas on National Forests will be done on
representative non-tally trees and only when absolutely necessary to estimate site, age, or
growth. (This will generally be the case during initial establishment of permanent plots.) [INTRAAGENCY AGREEMENT 05-SU-FIA01]
227
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
228
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Appendix F. Shrub and Vine Species Codes for the Maine Inventory
DECIDUOUS SHRUBS
Add a 9 prefix to each 3-digit code listed below. Eg., 9350
Code
Common name
Genus
Species
350
352
353
365
366
368
381
458
465
475
485
492
493
494
496
497
501
502
525
535
549
585
592
593
604
609
635
637
643
644
685
725
845
856
864
865
866
868
870
905
915
925
926
929
Alder spp.
speckled alder
Hercules club
chokeberry spp.
azalea spp.
barberry spp.
buttonbush
New Jersey tea
sweet pepperbush
fringetree
sweetfern
alternate-leaved dogwood
silky dogwood
round-leaved dogwood
gray-stemmed, or panicled dogwood
red-osier dogwood
American hazelnut
beaked hazelnut
leatherwood
autumn olive, or Russian olive
huckleberry spp.
witch-hazel
large-leaf holly
winterberry holly
fetter-bush spp.
common spicebush
bush honeysuckle spp.
male-berry, staggerbush spp.
sweet gale
bayberry
mountain-holly
ninebark
buckthorn spp.
azalea (deciduous) spp.
winged sumac
smooth sumac
staghorn sumac
poison sumac
currant, gooseberry spp.
Rose spp.
briar, bramble, dewberry spp.
American elderberry
red-berried elderberry
shrub willows spp. (all other willows
not indicated in tree codes
spirea spp.
American bladdernut
Blueberry spp.
Alnus
A.
Aralia
Aronia
Azalea
Berberis
Cephalanthus
Cleanothus
Clethra
Chionanthus
Comptonia
Cornus
C.
C.
C.
C.
Corylus
C.
Dirca
Elaeagnus
Gaylussacia
Hamamelis
Ilex
Ilex
Leucothoe
Lindera
Lonicera
Lyonia
Myrica
Myrica
Nemopanthus
Physocarpus
Rhamnus
Rhododendron
Rhus
R.
R.
R.
Ribes
Rosa
Rubus
Sambucus
S.
Salix
spp.
rugosa
spinosa
spp.
spp.
spp.
occidentalis
americanus
alnifolia
virginicus
peregrina
alternifolia
amomum (obliqua)
rugosa (circinata)
racemosa (paniculata)
stolonifera
americana
cornuta (rostrata)
palustris
angustifolia
spp.
virginiana
montana (monticola)
verticillata
spp.
benzoin
spp.
spp.
gale
pensylvanica
mucronatus
opulifolius
spp.
spp.
copallina
glabra
typhina
vernix
spp.
spp.
spp.
canadensis
racemosa
spp.
Spirea
Staphylea
Vaccinium
spp.
trifolia
spp.
937
982
983
229
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Species
Code
Common name
Genus
985
986
987
988
989
990
991
992
994
997
Viburnum spp.
maple-leaved viburnum
hobblebush viburnum
wild raisin, withe-rod
arrowwood
nannyberry
blackhaw
highbush cranberry
common prickly-ash
unknown or not listed
Viburnum
V.
V.
V.
V.
V.
V.
V.
Zanthoxylum
spp.
acerifolium
alnifolium
cassinoides
dentatum
lentago
prunifolium
trilobum
americanum
If species is not listed, use generic genus code.
EVERGREEN SHRUBS
Add a 9 prefix to each 3-digit code listed below. Eg., 9045
Code
Common Name
Genus
Species
045
061
232
357
605
606
607
608
642
855
945
998
leatherleaf
common juniper
Canada yew
bog rosemary
sheep laurel
mountain laurel
swamp laurel
Labrador tea
wax myrtle
rhododendron spp.
sweetleaf
unknown or not listed
Chamaedaphne
Juniperus
Taxus
Andromeda
Kalmia
K.
K.
Ledum
Myrica
Rhododendron
Symplocos
calyculata
communis
canadensis
glaucophylla
angustifolia
latifolia
polifolia
groenlandicum
cerifera
spp.
tinctoria
If species is not listed, use generic genus code.
DWARF SHRUBS
Add a 9 prefix to each 3-digit code listed below. Eg., 9363
Code
Common Name
Genus
Species
363
364
441
442
498
547
548
603
615
618
675
677
bearberry
alpine bearberry
striped pipsissewa
pipsissewa
bunchberry
creeping snowberry
teaberry
diapensia
twinflower
alpine azalea
partridgeberry
three-toothed cinquefoil
Arctostaphylos
Arctous
Chimaphila
Chimaphila
Cornus
Chiogenes
Gaultheria
Diapensia
Linnaea
Loiseleuria
Mitchella
Potentilla
uva-ursi
alpinus
maculata
unbellata cisatlantica
canadensis
hispidula
procumbens
lapponica
borealis americana
procumbens
repens
tridentata
230
981
996
cranberry spp.
unknown or not listed
Vaccinium
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
spp.
If species is not listed, use generic genus code.
VINES
Add a 9 prefix to each 3-digit code listed below. Eg., 9451
Code
Common Name
Genus
Species
451
454
455
477
636
715
867
934
993
995
hog peanut
ground-nut
American bittersweet
clematis sp.
vine honeysuckle
Virginia creeper
poison ivy
Greenbrier spp.
Grape spp.
unknown or not listed
Amphicarpa
Apois
Celastrus
Clematis
Lonicera
Parthenocissus
Rhus
Smilax
Vitis
bracteata
americana
scandens
spp.
spp.
quinquefolia
radicans
spp.
spp.
If species is not listed, use generic genus code.
231
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
232
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Appendix G. Quality Control / Quality Assurance Program in the Northeast
Our resource inventories are designed to satisfy specified precision objectives. Much of our resource
information comes from a very small sample of actual ground conditions. Our sampling system is
statistically sound. The sample plots selected will satisfy the stated precision objectives, if the ground
data is free of errors. While there is no way in which the latter can be completely assured, it is obvious
that field errors must be kept to a minimum. This objective can be accomplished by establishing and
adhering to a Quality Control / Quality Assurance (QC/QA) Program. By setting standards and monitoring
fieldwork, we can prevent or at least detect and correct errors, and eliminate the repetition of most errors.
After the initial training period, periodic inspections will be made of every crew's fieldwork. Inspections
are the most important mechanism for assuring quality data. Every plot installed has a chance to be
inspected. The overall goal shall be to inspect at least 10% of the plots installed. The number of errors
detected will determine frequency of inspections. All instances of error will be analyzed and discussed
with the crew concerned. Three distinct types of inspections are done: hot checks, cold checks and blind
checks. For each type of check, there are national minimal targets: 2 % for hot, 5 % for cold, and 3% for
blind.
Hot checks (QA status 7) are normally done as part of the training process. Quality control at the time
of data collection is the easiest method for identifying errors. Hot checks are informal, allowing for oneon-one interaction between the trainer and the trainee. Errors encountered during hot checks are
corrected.
Cold checks (QA status 2) are done on regular intervals throughout the field season, but may be more
frequent for less experienced crews, and less frequent for experienced crews. The inspectors shall select
from completed plots to perform cold checks. It is discretion of the inspector as to which variables are
checked. Inspectors should use judgment to concentrate their efforts on the variables that are more likely
to contain errors. Errors encountered during cold checks are corrected.
Blind checks (QA status 6) need to be performed in a systematic manner to yield statistically valid data
to evaluate the accuracy and repeatability of each variable. Blind checks are to be completed by qualified
inspections crews only. Prior to the field season a random selection of plots will be determined at
Newtown Square for blind checks. Field crews will not be informed as to which plots have been selected
for blind checks. Inspection crews will complete these plots within 2 weeks of the plot completion by the
field crew. A blind check must contain a complete set of variable measurements, and the data set must
be maintained separately from the original data. No corrections of original data are permitted.
Many of the entries for variables on the tally record are, or can be, obtained by measurements. When
those measurements can be repeated with uniform results by several individuals, it is proper to set close
tolerance limits that define acceptable data.
There are also many variables that require some degree of subjective evaluation. The attributes with the
greater subjectivity should have broader tolerance limits. While it would be desirable for every crew to
have the exact same entries for all such variables, it is not a realistic goal. However, it is possible, and
should be the goal of all crews, to assign any given variable a similar value on a scale of values. For
example, if the scale of possible values is 1 through 5, it is reasonable to expect that all crews would be
within ± one level on the scale.
There are also variables designed to be answered yes/no, present/absent, or other entries that require
other mutually exclusive answers. Often the answer depends on the amount of time spent examining the
area. Crews are not expected to find needles in haystacks: they are expected to complete every required
variable, as best they can, based on their training, instructions received, and evidence on the plot.
The time required to complete a plot will vary with access, terrain, amount of tally, and numerous other
factors. In the past, the average on-plot time has been three to four hours. Supervisors will monitor
233
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
progress and goals, and minimum acceptable performance levels will be adjusted as conditions warrant.
The first priority of all crews will be quality work, performed safely.
Crews will be informed of any errors detected in their work. They will be expected not to repeat
those errors. The goal of this QA/QC program is to insure that all field data is of the highest
possible quality. If any variable of the field tally procedure is unclear, ask your supervisor for
clarification.
COMPLETENESS
It is the responsibility of each crew to complete all variables before leaving the sample plot. Appendix H
of the field guide contains guides and examples for many plot situations. The guides indicate which
variables must be completed. There will be no excuse for incomplete data unless there are very unusual
circumstances, and those circumstances have been explained in the PLOT NOTES of the tally record.
When plot data is collected and stored with the aid of a portable data recorder (PDR); the TALLY program
will ensure that required variables for a plot are complete based on PLOT STATUS, but there are many
important questions that are still answered on the tally records. It is incumbent upon the crew to make
sure that all required variables are completed before leaving the sample plot.
LEGIBILITY
Tally records are the basis for the inventory. Tally records that are not legible will be considered as
evidence of unsatisfactory work. If the recorded data is not legible enough to be processed correctly it is
useless, no matter how accurate it may have been.
A BASIC EDIT FOR COMPLETENESS AND OBVIOUS ERRORS MUST BE MADE BEFORE LEAVING
THE PLOT.
FIELD EDIT
The quality control process begins with the initial field edit by the crew. A crew is required to complete an
edit after the completion of each subplot and a final plot edit before leaving the plot area. If a crew is
using a PDR, then data errors should be at a minimum.
The current TALLY edit routine lists “warning” and “error” messages. When a crew reviews the message
list, they can either accept or change data with warnings. Errors indicate conflicting or invalid data.
These require the data to be changed unless the crew believes the error message is wrong. If the latter
is true, a crew needs to contact their supervisor.
Before leaving the plot, complete a thorough edit to make sure that all required fields are
complete, all entries are reasonable, and all photo work is complete. The editor indicates their
initials in the space provided. This is usually done by the person who cruised the plot.
When Collected: All plots
MO
FIELD EDIT
DAY
YR
xx
xx
xx
xxx
09
02
05
KMT
FIELD EDIT / MONTH
Record the month that the edit was completed.
When collected: All plots
Field width: 2 digits
Tolerance: No errors
MQO: At least 99% of the time
234
EDITOR'S
INITIALS
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Values:
January
February
March
April
01
02
03
04
May
June
July
August
05
06
07
08
September
October
November
December
09
10
11
12
FIELD EDIT / DAY
Record the day of the month that the edit was completed.
When collected: All plots
Field width: 2 digits
Tolerance: No errors
MQO: At least 99% of the time
Values: 01 to 31
FIELD EDIT / YEAR
Record the year that the edit was completed
When collected: All plots
Field width: 2 digits
Tolerance: No errors
MQO: At least 99% of the time
Values: > 03
OFFICE EDIT
As the name implies an office edit is completed off plot by the field crew. All paper tally records and
printouts are reviewed for errors. If an error is correctable in the office, the correction is made with a red
pencil, initialed by the editor and dated. If an error cannot be corrected in the office, the crew will need to
return to the plot to correct the error.
When a county is completed and sent to Newtown Square, Information Management personnel review all
plots and modify the electronic plot file, if applicable. It is very important that all corrections are
clearly marked in red, so there is no room for misinterpretation.
Before a plot is given to the field supervisor or QA staff, complete a thorough edit to make sure that all
required fields are complete, all entries are reasonable, and all photo work is complete. The editor
indicates their initials in the space provided.
When Collected: All plots
MO
OFFICE EDIT
DAY
YR
EDITOR'S
INITIALS
xx
xx
xx
xxx
09
06
05
REI
OFFICE EDIT / MONTH
Record the month that the edit was completed.
When collected: All plots
Field width: 2 digits
Tolerance: No errors
MQO: At least 99% of the time
Values:
January
February
March
April
01
02
03
04
May
June
July
August
05
06
07
08
September
October
November
December
235
09
10
11
12
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
OFFICE EDIT / DAY
Record the day of the month that the edit was completed.
When collected: All plots
Field width: 2 digits
Tolerance: No errors
MQO: At least 99% of the time
Values: 01 to 31
OFFICE EDIT / YEAR
Record the year that the edit was completed.
When collected: All plots
Field width: 2 digits
Tolerance: No errors
MQO: At least 99% of the time
Values: > 03
QC USE ONLY
This data item located at the top of the page 3 tally sheet is reserved for supervisors and QA personnel.
Supervisors or QA personnel indicate whether a field check or office edit was completed. All completed
plots must show this notation before being sent to Newtown Square. See example below.
QC USE ONLY: FIELD
OFFICE
DATE 1/8/04
INITIALS KT
This final edit or check is usually when plots are found with incomplete or inconsistent data that was not
found during the OFFICE EDIT. A log of errors is kept as supervisors and QA personnel complete these
checks. This information is given to the field crews so the errors do not recur on future plots. All office
edit corrections to the plot record are initialed (supervisor or QA personnel), dated and indicated in red
pencil or pen.
If a field check is indicated this means that a supervisor or QA personnel completed a field visit to verify
collected data. There are two types of field checks. These are “full” cold checks and verifications. A full
cold check (a.k.a. tree audit) is a thorough check of all data items that usually includes twenty trees.
These inspection dates should be no older than thirty days from the original production date. Verification
consists of reviewing conditions, land uses, boundaries, inconsistent data, etc. These inspection dates
can be older than thirty days from the original production date.
236
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Appendix H. Tally Record Guide
On the seven page sample record there are several variables that may require entries, either coded or
written, by the field crews.
Where a numbered variable requires a coded entry, the number of digits required for that entry is
indicated by the number of X's immediately below the variable number on the sample record. Some
variables require measurements to decimal fractions of inches or feet. For those items, it is understood
that the last digit represents a decimal fraction. For example, a tree DBH of 23.4 inches is coded as 234.
The decimal points are never placed in coded entries.
The entries for some variables will have been made in the office. These are usually variables 1.01NE
through 1.3 and 1.5+NE. These entries may be incorrect, but do not change any previously made entry
without the approval of your supervisor.
Notes should be recorded as often as needed to clarify coded entries and to explain unusual or unique
situations. Notes are also used to direct attention to anything about a particular plot that the crews think
is important now, or may be important when the plot is remeasured during the next inventory. If
necessary, attach extra sheets of notes. The value of notes cannot be overemphasized! Suffice it to
say that a few notes are made at a fraction of the cost that would be involved in going back to a plot to
answer questionable data.
Take a moment to read the statement printed on the inside cover of this document. Even though it was
written more than seventy years ago, this statement still applies to everything that we do today. Field
data collection is the most important part of this inventory. Everything that comes afterward is dependent
on a complete and accurate set of data.
The information to be recorded on the sample record is determined by the category of plot (SAMPLE
KIND) and the PLOT STATUS assigned by the field crew. Examples of the specific data variables
needed for each category of plot appear on the following pages.
Note: When using the portable data recorder the following information is displayed from plot history files
stored in the data recorder memory: plot identification and previous tree information (SUBPLOT
NUMBER, TREE RECORE NUMBER, SPECIES, HORIZONTAL DISTANCE, AZIMUTH, PREVIOUS
TREE CLASS / MERCHANTABILITY CLASS, PREVIOUS DBH, and PREVIOUS REGIONAL LAND USE
CLASS). In general, the variables that specifically apply to the previous inventory and the current
inventory (such as SPECIES, HORIZONTAL DISTANCE and AZIMUTH) are the variables that may be
changed.
Note: On the Tree Data tally guide, the field titled TREE CLASS will also serve to collect MERCH CLASS
information on Ohio SK 8 remeasurement of “prism” points 5 – 9. It has been renamed as TREE CLASS /
MERCH (OH). When applied to this special remeasurement, the field becomes 2-digits. TREE CLASS is
recorded as the 1st digit and MERCH CLASS is recorded as the 2nd digit. When this field is not being
used for the OH SK 8 “prism” point remeasurement, it remains a single digit field for TREE CLASS.
237
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Sampled w/ forest
(Plot Status = 1)
Sampled nonforest
(Plot Status = 2)
Nonsampled
(Plot Status = 3)
QA STATUS
CREW TYPE
CRUISER
TALLY
1.7.1NE
1.8-NE
1.9
1.10.1
1.10.2
1.10.3
1.10.4NE
1.10.5NE
1.11
1.12
1.12.1NE
1.14
1.15
1.15.1NE
1.15.2NE
x
xxxx
xx
xxxx
xx
xx
xxxx
xx
x
x
x
x
x
xxx
xxx
1
1
1
2, 5-8
1
3
2
1
2
2, 5-8
2
3
3
1
3
2, 5-8
3
3
All plots
All accessible forest land
Remeasure plots
Nonforest
Nonsampled
238
PLOT SEASON
TERRAIN POSITION
1.7+NE
1 OR 2 PERSON PLOT
WATER ON PLOT
x
DISTANCE TO
IMPROVED ROAD
1.6
xx
MONTH
SUBPLOTS EXAMINED
1.5
x
YEAR
PLOT NONSAMPLED
REASON
1.4
xxxx
DAY
PLOT STATUS
1.3-NE
xxx
MONTH
PLOT NUMBER
1.2
x
YEAR
COUNTY
1.1.1NE
xx
FIELD GUIDE VERSION
UNIT
1.1
x
PREVIOUS PLOT
NUMBER
STATE
1.0.2N
x
PREVIOUS
PHASE
PANEL
1.0.1NE
CURRENT
SAMPLE KIND
SUB-CYCLE
Tally record, page 1.
1.18.1NE 1.18.2NE
x
x
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Tally record, page 1 continued.
CONDITION DATA
NON-DELINEATING VARIABLES
CONDITION CLASS NUMBER
CONDITION CLASS
STATUS
CONDITION NONSAMPED
REASON
CURRENT REGIONAL
LAND USE
RESERVED STATUS
OWNER GROUP
FOREST TYPE
STAND SIZE CLASS
REGENERATION STATUS
TREE DENSITY
OWNER CLASS
PRIVATE OWNER
IDUSTRIAL STATUS
ARTIFICIAL
REGENERATION SPECIES
STAND AGE
DISTURBANCE 1
DISTURBANCE YEAR 1
DISTURBANCE 2
DISTURBANCE YEAR 2
DISTURBANCE 3
DISTURBANCE YEAR 3
TREATMENT 1
TREATMENT YEAR 1
TREATMENT 2
TREATMENT YEAR 2
TREATMENT 3
TREATMENT YEAR 3
PHYSIOGRAPHIC CLASS
2.4.1
2.4.2
2.4.3
2.5.0NE
2.5.1
2.5.2
2.5.3
2.5.4
2.5.5
2.5.6
2.5.7
2.5.8
2.5.9
2.5.10
2.5.11
2.5.12
2.5.13
2.5.14
2.5.15
2.5.16
2.5.17
2.5.18
2.5.19
2.5.20
2.5.21
2.5.22
2.5.23
x
x
xx
xx
x
xx
xxx
x
x
x
xx
x
xxxx
xxx
xx
xxxx
xx
xxxx
xx
xxxx
xx
xxxx
xx
xxxx
xx
xxxx
xx
Forest land
1
Nonforest
2
Noncensus water
3
Census water
4
Nonsampled
5
2.5.23.1NE 2.5.23.2NE2.5.23.3NE2.5.23.4NE
xx
x
x
ME
All plots
All accessible f
Remeasure plots
Nonforest
Nonsampled
ME MAINE only
239
STOCKING CLASS
STAND STRUCTURE
TREATMENT
STAND HISTORY
DISTURBANCE
TIMBER MANAGEMENT
CLASS
DELINEATING VARIABLES
x
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Tally record, page 1 continued.
BOUNDARY DATA
SLOPE CORRECTION FROM
S1 TO S2, S3 OR S4
SUBPLOT CENTER
CONDITION
MICROPLOT CENTER
CONDITION
SNOW / WATER DEPTH
CROWN CLOSUE -- MAINE
SUBPLOT CONDITION LIST
SUBPLOT NUMBER
PLOT TYPE
BOUNDARY CHANGE
CONTRASTING CONDITION
CLASS NUMBER
LEFT AZIMUTH
CORNER AZIMUTH
CORNER DISTANCE
RIGHT AZIMUTH
CONDITION CLASS LIST
SPECIES
DIAMETER
TOTAL LENGTH
AGE AT DIAMETER
3.2
3.3
3.3.1NE
3.4
3.5
3.6
3.7
3.8
3.9
3.10
4.2.1
4.2.2
4.2.3
4.2.4
4.2.5
4.2.6
4.2.7
4.2.8
7.2.1+NE
7.2.2
7.2.3-NE
7.2.4
7.2.5
x
x
xx
xxx
x
x
xxx
xxx
xx
x
xxxx
x
x
x
x
xxx
xxx
xx
xxx
xxxx
xxxx
xxx
xxx
xxx
Sampled w/ forest
1
Sampled nonforest
2
Nonsampled
3
SUBPLOT ASPECT
SUBPLOT NONSAMPLED
REASON
3.1
SUBPLOT SLOPE
SUBPLOT STATUS
SITE TREE DATA
SUBPLOT NUMBER
SUBPLOT DATA
ME
If SUBPLOT CONDITION LIST indicates more than one CONDITION
CLASS NUMBER, then BOUNDARY DATA is required.
All plots with CONDITION CLASS STATUS 1, 2 or 3
All boundaries
All accessible forest land
Remeasure subplots
Nonsampled
ME MAINE only
240
All accessible forest land
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Tally record, page 2.
6.3
6.4
6.5.1NE-ME
xxxx
x
xxx
x
xxxx
x
xx
ME
ME
ME
ME
ME
ME
ME
Dwarf shrubs
ME
ME
ME
Vines
All accessible forest land
ME
All plots
241
SEEDLING COUNT
NUMBER
SUBPLOT NUMBER
6.2
x
CONDITION CLASS
NUMBER
SEEDLING COUNT
NUMBER
6.1
SPECIES
CONDITION CLASS
NUMBER
MAINE SHRUB & VINE DATA
SPECIES
SUBPLOT NUMBER
SEEDLING DATA
6.5.2NE-ME 6.5.3NE-ME 6.5.5NE-ME
MAINE only
Shrubs
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Tally record, page 5.
Live or dead trees
L
ME
R
MAINE only
Remeasured subplot
CAUSE OF DEATH
DECAY CLASS
TREE CLASS
PREVIOUS DBH
PREVIOUS TREE CLASS /
MERCHANTABILITY CLASS
PREVIOUS LAND USE
TREE NOTES
x
COMPACT CROWN RATIO
x
CROWN CLASS
5.12.1NE 5.12.2NE
CF SOUONDNESS
x
CUBIC FOOT CULL
5.3
x
BF SOUNDNESS
5.12
xxx
BOARD FOOT CULL
5.9-NE
xx
LENGTH METHOD
5.7.4NE
x
ACTUAL LENGTH
5.7.2
x
5.12.3NE
5.12.4NE
5.14
5.15
5.16+NE
5.16.1NE
5.16.2NE
5.16.3NE
5.16.4NE
5.17
5.19
5.21
5.23
5.23.1NE
5.9.1
5.23.2-3NE
5.24.4NE
5.27+NE
xx
xx
xxx
xxx
x
xx
x
xx
x
x
xx
xx
x
x
xxx
xx
xx
xxx
ME
ME
TOTAL LENGTH
CONDITION CLASS #
5.7.1+NE
x
BOLE LENGTH
DIAMETER CHECK
5.7
x
SAWLOG LENGTH
DIAMETER
5.6
xxx
TREE GRADE
TREE HISTORY
5.4
xxx
TREE CONDITION CLASS
STANDING DEAD (Trees only)
5.5
xxxx
HORIZONTAL DISTANCE
5.8
xxx
SPECIES
5.2
x
TREE RECORD #
Dead trees
TREE AND SAPLING DATA
5.1
SUBPLOT #
D
Live trees
RECONCILE
Sawtimber
PRESENT TREE STATUS
S
PREVIOUS TREE STATUS
New trees
AZIMUTH
All trees
Live saplings 1.0-in to < 5.0-in DBH being tallied for the 1st time.
R
R
R
R
1-3
S
S
S
S
R
R
4-5
S
S
S
S
R
R
7-8
Live trees > 5.0-in DBH being tallied for the 1st time.
1-4
Standing dead trees > 5.0-in DBH being tallied for the 1st time.
R
D
5
R
D
6
D
D
Standing snags > 5.0-in DBH being tallied for the 1st time.
The following tally guide based on TREE HISTORY applies to all trees on SK 2 & 5-P3 (all subplots/microplots), 5 (all subplots/microplots), 6 (subplot/microplot 1 only) and 7 (subplot/microplot 1 only).
1
1
0
10
S
S
L
L
S
S
L
L
S
S
L
L
S
S
L
L
S
S
L
L
13
S
S
L
L
S
S
L
L
D
D
18
S
S
L
L
S
S
L
L
D
D
19
S
S
L
L
S
S
L
L
20
S
S
L
L
S
S
L
L
21
S
S
L
L
S
S
L
L
D
D
22
S
S
L
L
S
S
L
L
D
D
23
S
S
L
L
S
S
L
L
D
D
0
8
0
8
14
1 or 2
0
8
15
1 or 2
3
16
0
8
17
1 or 2 3 or 4
1
1
1 or 2
1
1 or 2
D
1, 3 or
1 or 2
4
1
1
L
12
1 or 2
2
L
L
11
1 or 2
1 or 2
S
3
1 or 2 3 or 4
1
L
S
00
1
D
1 or 2
2
1
24
S
S
L
L
S
S
L
L
D
D
2
3 or 4
25
S
S
L
L
S
S
L
L
D
D
27
S
S
L
L
S
S
L
L
D
D
1 or 2
D
Note: If STANDING DEAD =1 and TREE CONDITION CLASS = 7 or 8, record only those variables that are required for SNAGS.
Note: STANDING DEAD is not applicable on a sapling that has died.
242
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Tally record, page 5 continued. [Revised 12/12/2005.]
Live or dead trees
L
D
Live trees
Dead trees
ME
MAINE only
30 or 33
80
5.12.4NE
5.14
5.15
5.16+NE
5.16.1NE
5.16.2NE
5.16.3NE
5.16.4NE
5.17
5.19
5.21
5.23
5.23.1NE
5.9.1
5.23.2-3NE
5.24.4NE
5.27+NE
xx
xx
xxx
xxx
x
xx
x
xx
x
x
xx
xx
x
x
xxx
xx
xx
xxx
S
S
S
S
80
D
5.12.1NE 5.12.2NE
x
TOTAL LENGTH
5.12.3NE
x
TREE GRADE
TREE NOTES
0
PREVIOUS LAND USE
2
PREVIOUS TREE CLASS /
MERCHANTABILITY CLASS
1
PREVIOUS DBH
30
TREE CLASS
1
DECAY CLASS
2
CAUSE OF DEATH
1
COMPACT CROWN RATIO
x
CROWN CLASS
5.3
x
CF SOUONDNESS
5.12
xxx
CUBIC FOOT CULL
5.9-NE
xx
BF SOUNDNESS
5.7.4NE
x
BOARD FOOT CULL
5.7.2
x
LENGTH METHOD
5.7.1+NE
x
ACTUAL LENGTH
CONDITION CLASS #
5.7
x
BOLE LENGTH
DIAMETER CHECK
5.6
xxx
SAWLOG LENGTH
DIAMETER
5.4
xxx
TREE CONDITION CLASS
TREE HISTORY
5.5
xxxx
HORIZONTAL DISTANCE
5.8
xxx
SPECIES
5.2
x
TREE RECORD #
5.1
SUBPLOT #
STANDING DEAD (Trees only)
TREE AND SAPLING DATA
RECONCILE
Sawtimber
PRESENT TREE STATUS
S
PREVIOUS TREE STATUS
New trees
AZIMUTH
All trees
1
3
31
80
1
1, 2 or
3
D
32
D
1
1 or 2
D
33
1
3
S
S
L
L
1 or 2
0
9
38
1 or 2
0
9
39
1
2
1
40
1
2
0
41
1
2
0 or 1
42
1
2
1
43
1
2
0
44
1 or 2
0
5, 6, 7
or 8
S
S
S
1
53
4,5
53
7,8
2
2 or 3
D
54
S
S
S
S
S
Tally guide based on PRESENT TREE STATUS for live saplings, "no status" saplings, dead saplings standing or down, and removed saplings on SK 2 plots.
2
3
D
S
D
D
S
D
5
D
6
Note: STANDING DEAD is not applicable on a sapling that has died.
Note: If STANDING DEAD =1 and TREE CONDITION CLASS = 7 or 8, record only those variables that are required for SNAGS.
1
D
50
1
1
S
D
2
0
D
D
S
2
1
D
D
2
1
S
80
2
1
S
34
5-9
ME
243
ME
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
OH Tally record, page 5
All trees
New trees
S
Live or dead trees
Sawtimber
L
D
Live trees
Dead trees
ME
MAINE only
5.16.2NE
5.16.3NE
5.16.4NE
5.17
5.19
5.21
xx
x
xx
x
x
xx
xx
5.23
5.23.1NE 5.23.2NE 5.9.1
xxxx
x
xx
Reconcile all previously measured trees on Points 5, 6, 7, 8 & 9.
10
19
21
23
30
31
32
33
34
38
39
40
41
42
43
44
50
53
6
54
Tally new trees on a 6.8 ft microplot located at PC for Points 5, 6, 7, 8 & 9.
12
20
22
24
25
244
5.23.2-3NE
xxx
5.24.4NE
xx
TREE NOTES
5.16.1NE
x
PREVIOUS LAND USE
5.16+NE
xxx
PREVIOUS TREE CLASS /
MERCHANTABILITY CLASS
5.15
xxx
PREVIOUS DBH
5.14
xx
TREE/MERCH CLASS (OH)
5.12.4NE
xx
DECAY CLASS
5.12.3NE
MORTALITY YEAR
CAUSE OF DEATH
x
COMPACT CROWN RATIO
x
CROWN CLASS
5.12.1NE 5.12.2NE
CF SOUONDNESS
x
CUBIC FOOT CULL
5.3
x
BF SOUNDNESS
5.12
xxx
BOARD FOOT CULL
CONDITION CLASS #
5.9-NE
xx
LENGTH METHOD
DIAMETER CHECK
5.7.4NE
x
ACTUAL LENGTH
DIAMETER
5.7.2
x
TOTAL LENGTH
TREE HISTORY
5.7.1+NE
x
BOLE LENGTH
STANDING DEAD
5.7
x
SAWLOG LENGTH
RECONCILE
5.6
xxx
TREE GRADE
PRESENT TREE STATUS
5.4
xxx
TREE CONDITION CLASS
PREVIOUS TREE STATUS
5.5
xxxx
HORIZONTAL DISTANCE
5.8
xxx
SPECIES
5.2
x
TREE RECORD #
5.1
SUBPLOT #
AZIMUTH
TREE AND SAPLING DATA
5.27+NE
xx
xxx
LENGTH METHOD
UNCOMPACTED CROWN
RATIO
CROWN LIGHT EXPOSURE
CROWN POSITION
CROWN VIGOR (SAPS)
CROWN DENSITY
CROWN DIEBACK
CROWN TRANSPARENCY
DAMAGE LOCATION 1
DAMAGE TYPE 1
DAMAGE SEVERITY 1
DAMAGE LOCATION 2
DAMAGE TYPE 2
DAMAGE SEVERITY 2
live saplings on P3 plots will require these
additonal variables
live trees on P3 plots will require these
additonal variables
5.12
5.13
5.14
12.5
12.6
12.7
12.8
12.9
12.10
12.11
5.18.1
5.18.2
5.18.3
15.18.4
5.18.5
5.18.6
xxx
xxx
x
xx
x
x
x
xx
xx
xx
x
xx
x
x
xx
x
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
TOTAL LENGTH
These additional P3 variables are
required for all live saplings and
trees when Condition Class Status
= 1.
ACTUAL LENGTH
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
245
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Tally record, page 6.
ST
xx
UNIT
x
CNTY
xxx
PLOT #
xxxx
All plots
PLOT DIAGRAM
Sketch in the boundaries of any plot that has
mulitiple condition classes, as well as any
features that may facilitate the relocation of
the plot or subplots.
Be particularly careful to sketch condition
boundaries that occur within the subplot
accurately as possible (include azimuths).
For plots where all 4 subplots fall entirely
within one condition, clearly note on this page:
"All Conditon Class 1).
246
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Tally record, page 7.
ST
xx
UNIT
x
CNTY
xxx
PLOT #
xxxx
All accessible forest land
Stocking check for accessible forest land
All plots
PLOT NOTES:
This area is used for notes about the plot, subplot or
individual tally variables.
All changes in land use must be documented in this section.
Describe the land use for all nonforest plots in this section
(e.g., Entire plot falls in cropland without trees -- LU = 61)
STAND AGE WORKSHEET
RING COUNT PLUS 5 YEARS
PERCENT OF OVERSTORY
WEIGHTED AGE
CONDITION CLASS #
SPECIES
RING COUNT PLUS 5 YEARS
PERCENT OF OVERSTORY
WEIGHTED AGE
CONDITION CLASS #
SPECIES
RING COUNT PLUS 5 YEARS
PERCENT OF OVERSTORY
WEIGHTED AGE
CONDITION CLASS #
SPECIES
RING COUNT PLUS 5 YEARS
PERCENT OF OVERSTORY
WEIGHTED AGE
STAND AGE WORKSHEET
SPECIES
STAND AGE WORKSHEET
CONDITION CLASS #
STAND AGE WORKSHEET
x
xxxx
xxx
xx
xxx
x
xxxx
xxx
xx
xxx
x
xxxx
xxx
xx
xxx
x
xxxx
xxx
xx
xxx
100%
100%
STOCKING CHECK WORKSHEET
100%
STOCKING PLOT REFERENCE DIAGRAM
STOCKING CHECK WORKSHEET
DBH of the largest tally tree on the plot =
DBH of the largest tally tree on the plot =
Column used from Table 5a + 5b:
Column used from Table 5a + 5b:
XX.X
SUBPLOT NUMBER
PLOT TYPE
SPECIES
DBH
NUMBER TALLIED BY
DBH SIZE CLASS
STOCKING VALUE
CUMULATIVE TOTAL
SUBPLOT NUMBER
PLOT TYPE
SPECIES
DBH
NUMBER TALLIED BY
DBH SIZE CLASS
STOCKING VALUE
CUMULATIVE TOTAL
X
x
x
xxxx
xxx
x
xx.x
xx.x
x
x
xxxx
xxx
x
xx.x
xx.x
247
100%
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Tally record, page 3.
QC USE ONLY: FIELD
OFFICE
INITIALS
DATE
PLOT DATE:
MON
DAY
YEAR
GPS COORDINATES [NAD83]
LATITUDE
Printed label with plot identification and photo information.
DEG
+ xx
1.16.7.1-3NE
MIN
xx
SEC
xx.xx
LONGITUDE 1.16.8.1-3NE
DEG
- xxx
MIN
xx
SEC
xx.xx
SP
LATITUDE
DEG
+ xx
1.16.7.1-3
MIN
xx
SEC
xx.xx
LONGITUDE 1.16.8.1-3
DEG
- xxx
MIN
xx
SEC
xx.xx
DIST CORRECTION
TO PC
GPS ELEVATION
GPS ERROR
1.16.6
x
1.16.13
xxx
1.16.14
xxx
1.16.15-NE
x xxxx
1.16.16
xxx
OWNER CONTACT?
NUMBER OF GPS
READINGS
AZ CORRECTION
TO PC
GPS UNIT
1.16.3 1.16.3.1NE
x
x
GPS PDOP
COORDINATE
SYSTEM
1.16.4
xxxxxx
GPS LOCATION
GPS SERIAL #
PC
1.16.16.1NE
x.x
N
CONTACT DATE
ON-SITE [ ]
LETTER [ ]
TELEPHONE [ ] #
1.16.17
xxx
POSTED?
±
1
Y
Y
N
NAME
INFO. QUALITY
Complete ownership information for plot center at subplot 1 if forested.
ADDRESS
CITY/ ST/ ZIP
SOURCE
TWP/MAP/SEC
DBH -
STARTING POINT: SPECIES -
COURSE TO PLOT (cont.)
DIST
SC
SPP
DBH
DIS
DIR
NOTES
Provide notes about the starting point for all plots.
All plots
WITNESSED BY SPEC
DBH
HD
AZ
All plots where Plot Staus = 1 or 2.
NOTES
All plots where PC is occupied.
PLOT CENTER WITNESSED BY -
New SPs only
LINE NO.
SPEC
DBH
HD
AZ
NOTES
All plots -- Supervisor or QA staff only
COURSE TO PLOT
DISTANCE
AZIMUTH
FEET
DIST
SC
SPP
DEG
DBH
DIS
DIR
NOTES
248
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Tally record, page 4.
ST
UNIT
CTY
PLOT #
xx
x
xxx
xxxx
FIELD CREW
CRUISER
TALLY
xxx
xxx
MO
FIELD EDIT
DAY
YR
xx
xx
xx
OWNERSHIP & PLOT LOCATION NOTES:
EDITOR'S
INITIALS
xxx
MO
xx
OFFICE EDIT
DAY
YR
xx
xx
EDITOR'S
INITIALS
xxx
CALCULATIONS
Record any additonal information regarding ownership, plot and/or
subplot relocation. Notes pertaining to condition or specific tally
variables should be written in the plot notes (back of the plot diagram).
If applicable, show calculations
used to determine the course to
plot.
ALL PLOTS
Draw a sketch map of the general plot location that provides enough
details so that the starting point can be relocated without the use of
aerial photography or GPS. Include the distance to the nearest town,
major road intersections, the locations of the SP and PC, as well as
any additional landmarks that may be useful. Record distances that
are driven in miles and tenths of miles, and distances that are walked
in feet or chains.
All plots
249
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
250
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Appendix I – Special Studies
Field Instructions for Pennsylvania’s Regeneration Study (PRS) ............................................................. 1
0.0 Overview.............................................................................................................................................. 1
1.0 Plot Data.............................................................................................................................................. 2
1.1 State, Unit, County, and Plot Number ................................................................................................. 2
1.2 Month/Day/Year................................................................................................................................... 2
2.0 Subplot Data........................................................................................................................................ 3
2.1 Subplot Number................................................................................................................................... 3
2.3 Site Limitations .................................................................................................................................... 3
2.4 Competing Vegetation......................................................................................................................... 4
2.5 Species/Life Form ............................................................................................................................... 4
2.6 Percent Cover Class ........................................................................................................................... 4
3.0 Microplot Data ..................................................................................................................................... 5
3.1 Microplot Number ................................................................................................................................ 5
3.2 Microplot Center Condition Class........................................................................................................ 5
3.3 Site Limitations .................................................................................................................................... 5
3.4 Dominant Tree..................................................................................................................................... 5
3.5 Tree and Seedling Data ...................................................................................................................... 5
3.5.1 Species............................................................................................................................................. 5
3.5.2 Seedling Source ............................................................................................................................... 5
3.5.3 Height Class ..................................................................................................................................... 6
3.5.4 Numbers of Stems............................................................................................................................ 6
Exotic Species Survey: Tally Procedures and Species List..................................................................... 9
0.0 Overview.............................................................................................................................................. 9
1.0 Tally Procedures ................................................................................................................................. 9
2.0 Exotic Survey Species List ................................................................................................................ 11
Field Instructions for Pennsylvania’s Regeneration Study (PRS)
0.0 Overview
The regeneration assessment is being conducted in Pennsylvania at the request of the State’s forestry
community. There is concern that regeneration is lacking in many stands and with over half of the State’s
forests in a financially mature condition, this is a critically important issue. The regeneration data will
provide answers to questions about advance regeneration, post-disturbance regeneration, and future
forest composition. The data will be used to quantify regeneration adequacy statewide, provide estimates
of numbers of seedlings per acre, and for research into regeneration dynamics. Regeneration plots are
selected prior to the field season and are visited during the leaf-on season from June through September.
The figure on the next page summarizes measurements needed for the regeneration assessment. Data
are collected at three levels: the entire sample plot, the subplot, and the microplot. The associated
vegetation and regeneration tallies should be completed for all accessible forest land conditions
that are encountered.
PRS: I - 1
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Plot Level
Sample Plot
Deer Impact: Record one of five classes:
Very Low
Low
Medium
High
Very High
Microplot Level
Site Limitations
Dominant Tree: If present, record the species of the
most dominant growing-stock tree at
least 5.0 inches in diameter.
Subplot Level
Site Limitations
Seedling Tally: Count all established seedlings by:
Competing Vegetation: Assign percent cover classes
to species/life form.
Species
Species/Life Form
Shrubs
Vines
Rhizomous fern
Other fern
Grass and forbes
Other herbaceous
Seedling Source
Stump sprout
Other seedling
Competitive oak, hickory, walnut, or butternut seedling
Height Class
2 inches to 6 inches
6 inches to 1 foot
1 foot to 3 feet
Percent Cover Class
Numbers of Stems
1.0 Plot Data
1.1 State, Unit, County, and Plot Number
Refer to Section 1 of this field guide.
1.2 Month/Day/Year
Refer to Section 1 of this field guide.
PRS: I - 2
3 feet to 5 feet
5 feet to 10 feet
Greater than10 feet
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
1.3 Deer Impact
Estimate the amount of browsing pressure that deer are exerting on regeneration. Deer impact is a
function of deer population and the amount of available food sources within one-square mile surrounding
the plot.
Code
1
2
3
4
5
Definition
Very Low - Plot is inside a well-maintained deer exclosure.
Low - No browsing observed, vigorous seedlings present (no deer exclosure present).
Medium - Browsing evidence observed but not common, seedlings present.
High - Browsing evidence common OR seedlings are rare.
Very High - Browsing evidence omnipresent OR forest floor bare, severe browse line.
Degree of deer browsing can be a difficult variable to quantify due to preferences that deer have for
various food sources and the elusive nature of deer populations. Although not a complete list of species
in Pennsylvania, the following deer preference list may be useful for assigning deer impact:
Species
Black Cherry
Fern
Grass & Sedge
Striped Maple
American Beech
Birches
Oak
Hickory
Ash
Rubus spp.
Pin Cherry
Red Maple
Sugar Maple
Yellow-poplar
Cucumbertree
Eastern Hemlock
Browse
Preference
L
L
L-M
L-M
M
H
H
H
H
H
H
H
H
H
H
H
Tolerance of
Browsing
L
H
H
H
H
M
M-H
M-H
M
M-H
L
L
L
L
L
L
In addition, a handout showing the Pennsylvania Game Commission’s estimates of deer density by
county will be provided. Deer densities in excess of 20 deer per square mile of forest are generally
considered to inhibit the development of tree seedlings.
2.0 Subplot Data
Complete the subplot data for all forested conditions.
2.1 Subplot Number
Record the code corresponding to the subplot number.
2.2 Condition Class Number
Record the corresponding condition class number.
2.3 Site Limitations
PRS: I - 3
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Record site limitation codes 2 and 3 if they occur on at least 30 percent of the subplot or condition area,
else record as code 1.
Code
1
2
3
Definitions
No site limitations
Rocky surface with little or no soil
Water-saturated soil (during the growing season)
2.4 Competing Vegetation
Assign percent cover classes to species/life forms within the subplot. The sum of the percent cover
classes may exceed 100 percent. For subplots with more than one condition, only record percent cover
for the portion of the subplot in the condition. For example, if 50 percent of the subplot is in a condition
and is entirely covered with Rubus spp., record 99 for percent cover class (100 percent cover).
2.5 Species/Life Form
Code
0001
0002
0003
0004
Definition
Deciduous Shrubs, all valid NEFIA species codes (see Appendix F)
Evergreen Shrubs, all valid NEFIA species codes (see Appendix F)
Vines, all valid NEFIA species codes (see Appendix F)
Invasive Vines, Shrubs and Forbs (see footnote for selected invasives1)
Rhizomous Fern, including Bracken, Hay-scented, and New York
Other Fern
Grass
Other Herbaceous
2.6 Percent Cover Class
Assign a cover class to each species or life form.
Code
01
10
20
30
40
Definition
1 to 9 percent
10 to 19 percent
20 to 29 percent
30 to 39 percent
40 to 49 percent
Code
50
60
70
80
90
Definition
50 to 59 percent
60 to 69 percent
70 to 79 percent
80 to 89 percent
90 to 100 perecnt
As an aid in determining percent cover, consider that one-percent cover of the 24-foot radius subplot is
equivalent to a square 4.2 feet on each side or a circle with a radius of 2.4 feet. Ten percent cover is
equivalent to a square 13.4 feet on each side or a circle with a radius of 7.6 feet.
1
Invasives to include are describes in the INVASIVE PLANTS FIELD GUIDE. The following codes are
applied to this study only. Do not apply these codes to other P2 or P3 data collection variables. The
codes to include in the Species/Life Form tally include the vines, shrubs, and two forbs listed below.
Vines
9882
Fiveleaf akebia
9883
9456
9884
9885
9886
Porcelain-berry
Oriental bittersweet
English ivy
Mile-a-minute vine
Kudzu
Shrubs
Winged
9888
Euonymous
Border privet
9889
Common privet
PRS: I - 4
Forbs
9899
Japanese knotweed
Giant knotweed
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
9887
Common periwinkle
3.0 Microplot Data
Complete the microplot data for microplots within accessible forest land.
3.1 Microplot Number
Record the code corresponding to the microplot number (same as subplot number).
3.2 Microplot Center Condition Class
Record the corresponding condition class number.
3.3 Site Limitations
Record the following site limitation if it dominates the area of the microplot or condition:
Code
1
2
3
4
Definition
No site limitation
Rocky surface with little or no soil
Water-saturated soil (during the growing season)
Thick duff layer (in excess of two-inches thick)
3.4 Dominant Tree
Record the presence/absence of at least one growing-stock tree 5.0-inches or larger in diameter at breast
height on the microplot or condition by recording species code. If there are no such trees, record as
“000.” If more than one such tree is present, record the species code of the tree with the largest
diameter.
3.5 Tree and Seedling Data
Tally all established seedlings (<1.0-inch DBH) for stems rooted within the microplot by species, seedling
source, and height class.
Count all seedlings at least 2-inches tall with at least two normal-sized leaves that do not still bear
cotyledons.
For most species encountered, the tug test should be used to determine if seedlings are established.
Seedlings that slip out of the ground with a slight tug do generally not have sufficient root systems to
survive through the growing season and are not established.
•
Small oak, hickory, walnut, and butternut seedlings (less than 1-foot tall) should be at least 6inches tall or have a root-collar diameter (RCD) of at least 0.20 inches.
•
Pine seedlings should have at least two whorls or be at least 6-inches tall.
3.5.1 Species
Record valid NE-FIA tree species code (see Appendix 3).
3.5.2 Seedling Source
Discriminate between stump sprouts and other seedlings. Tally clumps of stump sprouts as one seedling
and tally only the tallest, most dominant sprout for each stump. Tally sprouts on stumps that originate
from cutting or mortality only. Stumps must be at least 2 inches in diameter to qualify as having sprouts.
PRS: I - 5
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
A special code (3) is used for oak, hickory, walnut, and butternut that are classified as “competitive.”
Research indicates that competitive seedlings are highly likely to become dominant or codominant stems
in the next stand. To be classified as competitive, stems must have an RCD > 0.75 inches. In situations
with relatively high tally, it should only be necessary to check a few RCD’s.
Code
1
2
3
Definition
Stump sprout
Other seedling
Competitive oak, hickory, walnut, or butternut seedling
3.5.3 Height Class
Each seedling is assigned a height class.
Code
1
2
3
Definition
2 inches to 6 inches
6 inches to 1 foot
1 foot to 3 feet
Code
4
5
6
Definition
3 feet to 5 feet
5 feet to 10 feet
Greater than 10 feet
3.5.4 Numbers of Stems
Record the number of tree seedlings in each category described by species, seedling source, and height
class. The first five seedlings of each species must be counted precisely. Counts above five may be
estimated. In the case of beech root suckers, count all individuals unless they arise from a single root
node, in which case they should be counted as a single stem.
PRS: I - 6
PLOT #
MONTH
DAY
YEAR
DEER
IMPACT
XXXX
XX
XX
XXXX
X
PERECNT COVER
CLASS
MICROPLOT #
MICRO CENTER
COND CLASS #
SITE LIMITATIONS
DOMINANT TREE
SPECIES
SEEDLING SOURCE
HEIGHT CLASS
NUMBERS OF STEMS
X
XXX
SPECIES/LIFE FORM
CONDITION CLASS #
X
COUNTY
UNIT
X
SITE LIMITATIONS
STATE
XX
SUBPLOT #
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
X
XXX
XX
X
X
X
XXX
XXX
X
X
XXXX
PRS: I - 7
PRS: I - 8
> 10 ft
5 - 10 ft
Competitive oak, hickory, walnut, butternut (3)
2
3
4
5
6
3 - 5 ft
1
1 - 3 ft
6 in - 1 ft
6
6 in - 1 ft
2 - 6 in
5
2 - 6 in
> 10 ft
Stump Sprouts (1)
3
4
> 10 ft
2
5 - 10 ft
1
3 - 5 ft
6
1 - 3 ft
5
5 - 10 ft
Other Seedlings (2)
3
4
3 - 5 ft
2
1 - 3 ft
1
6 in - 1 ft
SPECIES
POINT #
Height Class
2 - 6 in
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Exotic Species Survey: Tally Procedures and Species List
0.0 Overview
The Exotics Survey is being implemented on the Pennsyvlania Regeneration Study (PRS) sample plots.
The survey utilizes a list of invasive trees, vines, shrubs, flowers, and grasses developed from state and
federal lists of invasive species associated with forest and forest-related habitats. Most of the species on
the list are exotics; however, some natives are included. The Survey will identify PRS subplots where
invasive species are found. Once complete, the results will provide an extensive view of invasive species
distributions in Pennsylvania. Although the measurements are simple observations of occurrence, the
results will indicate how many subplots the invasives occur on. These findings will supplement other
studies of invasive species being conducted by cooperating institutions.
1.0 Tally Procedures
The Exotics Survey is conducted at each sample location where PRS study measurements are
conducted--on all forested conditions that are encountered. Tally procedures consist of examination of
each subplot for occurrence of one of the species or species groupings listed on the Exotics Survey Tally
Sheet. If the species is identified and is rooted within the subplot, list the subplot number next to each
species or species group. There is no need to consider condition boundaries, except to confirm that the
species is rooted within the forested portion of the subplot.
For example, the picture below illustrates the procedure for a tally of one Tree-of-heaven on subplot 1
and mile-a-minute vine on all four subplots.
Instructions for entering data on the Personal Data Recorders (PDR) is provided in the help screen of the
PDR.
Exotic: I - 9
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Exotic: I - 10
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
2.0 Exotic Survey Species List
The following is a list of invasive species and species groups that are applied to this study only. Do not
apply these codes to other P2 or P3 data collection variables.
Trees
9320
9341
9712
9861
Norway maple, Acer platanoides
Tree-of-heaven, Ailanthus alitissima
Empress tree, Paulownia tomentosa
Bradford pear, Pyrus calleryana
Vines
9882
9883
9456
9884
9636
9885
9886
9887
Fiveleaf akebia, Akebia quinata
Porcelain-berry, Ampelopsis brevipedunculata
Oriental bittersweet, Celastris orbiculatus
English ivy, Hedera helix
Japanese honeysuckle, Lonicera japonica
Mile-a-minute vine, Polygonum perfoliatum
Kudzu, Pueraria lobata
Common periwinkle, Vinca minor
Shrubs
9368
9535
9888
9889
9635
9845
9906
9916
9938
9993
9994
Japanese barberry, Berberis thunbergii
European barberry, Berberis vulgaris
Russian olive, Elaegnus angustifolia
Autumn olive, Elaegnus umbellata
Winged Euonymus, Euonymus alatus
Border privet, Ligustrum obtusifolium
Common privet, Ligustrum vulgare
Bell’s honeysuckle, Lonicera morrowii x tatarica (include only the honeysuckle
species listed)
Amur honeysuckle, Lonicera maackii
Morrow’s honeysuckle, Lonicera morrowi
Standish honeysuckle, Lonicera standishii
Tartarian honeysuckle, Lonicera tatarica
Common buckthorn, Rhamnus catharticus
Glossy buckthorn, Rhamnus frangula
Multiflora rose, Rosa multiflora
Wineberry, Rubus phoenicolasius
Japanese spiraea, Spiraea japonica
Linden viburnam, Viburnam dilatatum
Guelder rose, Viburnam opulus
Forbs and Grasses
Garlic mustard, Alliaria petiolata
9890
Spotted knapweed, Centaurea maculata
9891
Canada thistle, Cirsium arvense
9892
Bull thistle, Cirsium vulgare
Crown-vetch, Coronilla varia
9893
Giant hogweed, Heracleum mantegazzianum
9894
Purple loosestrife, Lythrum salicaria
9895
Japanese stiltgrass, Microstegium vimineum
9896
Reed canary grass, Phalaris arundinacea
9897
Exotic: I - 11
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
9898
9899
9900
Common reed, Phragmites australis
Japanese knotweed, Polygonum cuspidatum
Giant knotweed, Polygonum sachalinensis
Other invasive plants observed (optional)
Exotic: I - 12
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
INVASIVE SPECIES IN PENNSYLVANIA
Mo Day Yr
County
Crew
Plot
X =present
Sub
Plot Code
SCIENTIFIC NAME
COMMON NAME
42
State
Date
NOTES
TREES
0
1
Acer platanoides
Norway maple
milky sap, buds not pointed like sugar maple, samaras spread at nearly 180
2
Ailanthus altissima
Tree-of -heaven
coarse twigs and pinnate leaves to 1m long
3
Paulownia tomentosa
Empress tree
leaves opposite or whorled, simple, blades broadly cordate-ovate, velvety pubescent on both sides
4
Pyrus calleryana
Bradford pear
leaves ovate, glossy, and somewhat leathery, leaf margins bearing rounded teeth
Fiveleaf akebia
leaves evergreen, alternate, palmately compound with 5 oval leaflets, problem in Philadelphia area
VINES
5
Akebia quinata
6
Ampelopsis brevipedunculataPorcelain-berry
lobed leaves, tendrils without adhesive disks, fruit a bright blue berry
7
Celastrus orbiculatus
Oriental bittersweet
fruit in axis of leaves, (native sp. has fruit only at end of vine, fruit more yellowish in color)
8
Lonicera japonica
Japanese honeysuckle
hairy underside of leaf, young leaves fern like, (native vine-leaves waxy, no hairs, fused at base)
9
Polygonum perfoliatum
Mile-a-minute vine
leaves triangular, barbs on leaf petioles and leaf midrib, slender annual vine
Kudzu
leaves trifoliate, leaflets broadly ovate
11 Berberis thunbergii
or
Japanese barberry
single spine, leaf margins entire (native barberry extirpated from PA, last found in Huntington Co.)
European barberry
compound spines mostly 3 pronged, leaves obovate with margins bearing very fine small spines
12 Elaegnus angustifolia
or
Russian olive
leaves covered with silvery scales on both surfaces
Autumn olive
leaves becoming green and glabrescent above
13 Euonymus alatus
Winged Euonymus
corky ridges on twigs. (native euonymus does not have corky ridges on twigs, much larger leaves)
14 Ligustrum obtusifolium
Border privet
Privet leaves opposite, with no leaf scar between leaves (there are no native privets)
or
Common privet
(Honeysuckles have leaf scar between leaves)
10 Pueraria lobata
SHRUBS
Berberis vulgaris
Elaegnus umbellata
Ligustrum vulgare
15 Lonicera morrowii x tatarica Bell's honeysuckle
or
(Non-native bush honeysuckles have white flowers with white or hollow pith)
Lonicera maackii
Amur honeysuckle
leaves ovate to lance-ovate, acuminate, not hairy, fruit dark red
Lonicera morrowii
Morrow's honeysuckle
leaves oblong to narrowly elliptic, softly pubescent beneath, fruit orange to red
Lonicera standishii
Standish honeysuckle
(Native honey suckles have yellow flowers)
Lonicera tatarica
Tartarian honeysuckle
leaves ovate to oblong, glabrous beneath, fruit red
Common buckthorn
edge plant, leaves opposite (native buckthorn never has spine, grows on wet limestone soils)
Glossy buckthorn
grows in boggy areas, leaves alternate
17 Rosa multiflora
Multiflora rose
conspicuouly fringed stipule at base of leaf petiole
18 Rubus phoenicolasius
Wineberry
dense very fine bristles on stems
19 Spiraea japonica
Japanese spiraea
much larger leaves than native sp. and flowers flat topped, native sp has columnar flowers
20 Viburnum dilatatum
Linden viburnum
leaves coarsely toothed, pubescent on both sides
21 Viburnum opulus
Guelder rose
Resembles native Viburnum trilobum, has concave-topped petiolar glands vs. dome shaped for trilobum
Garlic mustard
white four petal flowers, crushed leaves smell like garlic
or
or
or
16 Rhamnus catharticus
or
Rhamnus frangula
FLOWERS AND GRASSES
22 Alliaria petiolata
Exotic: I - 13
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Exotic: I - 14
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Appendix J. LandMark CE 1.01 NE-FIA Users Manual
0.0 Starting LandMark CE............................................................................................................................. 1
1.0 Screen Selection ..................................................................................................................................... 1
2.0 Gps Screen ............................................................................................................................................. 1
3.0 Nav Screen ............................................................................................................................................. 2
4.0 Cnf Screens ............................................................................................................................................ 2
5.0 Wpt Screens............................................................................................................................................ 4
6.0 LandMark CE / EMTAC GPS FAQs........................................................................................................ 6
7.0 User Support ........................................................................................................................................... 7
0.0 Starting LandMark CE
LandMark CE is ready for use after it has been installed on the Allegro and the Bluetooth GPS receiver
bonded to that Allegro.
To begin using LandMark CE, double-tap the LandMark CE icon on the desktop. The following screen
will appear.
Important note on using LandMark CE the first time
after it is installed:
Click the “Cnf” button. Change the COM Port setting
to match the Bluetooth COM Port that was displayed
during the GPS receiver bonding process.
Close LandMark CE and restart the program.
1.0 Screen Selection
LandMark CE has four operational screens that are accessed on the top bar. These are the current GPS
location screen (Gps), the Navigation Screen (Nav), the Configuration Screen (Cnf), and the Waypoint
Screen (Wpt).
2.0 Gps Screen
The Gps screen (shown above) displays the current GPS position and other relevant information. In the
upper left is a Skyplot, which is a graphical representation of the satellite positions directly overhead. The
outer circle represents the horizon and the inner circle is 60° above the horizon. The satellites are
displayed by their unique satellite number. Satellites used to compute the current GPS position are
shown in a square. When an EMTAC GPS receiver is used, the WAAS satellites are used but are not
displayed. To the right of the Skyplot is the satellite signal strength graph. The vertical bar represents
50% of maximum power. Below the Skyplot are the current coordinates, elevation, GPS Quality (2D, 3D,
2D Diff, 3D Diff, No Fix, No Comm. Act.), the PDOP, and the EHE. The Diag box shows individual
satellite details and NMEA string data.
J-1
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
3.0 Nav Screen
The Nav screen allows users to calculate distances and
azimuth between points and navigate to a location. The
upper left portion of the screen contains two drop down
lists of saved waypoints or the current “Here” position.
The From and To lists are used to select waypoints from
which the calculations will be performed. Below the
waypoint drop down lists is the compass. The compass
rotates to show the direction of travel once you start
moving. The arrow is fixed and always points toward the
To location. The compass body rotates to show the
current direction of travel. The Here → To section shows
calculated values based on the current GPS location and
the destination (To) location.
The From → To section displays the calculations based on the From location to the To location. Use this
section when calculating course-to-plot distance and azimuth between a saved SP waypoint and a saved
PC waypoint.
Displayed at the bottom of the Nav screen are the GPS Quality, heading setting, PDOP and EHE values.
4.0 Cnf Screens
The Cnf screen allows you to customize critical
LandMark CE settings.
The first screen to appear is the GPS screen. The only
option that needs changed here is the Com Port. It must
match the Bluetooth Com Port setting when the GPS
receiver was bonded to the Allegro. It will vary from unit
to unit. When the Com Port is changed, LandMark CE
must be shut down and restarted.
The other defaults that never need changed are:
Baud=9600, Parity=None, Data Bits=8, Stop Bits=1.
DTR and RTS do not need selected.
The File tab displays where waypoints and data are
stored on the Allegro.
When the Ini File Write Protected box is checked, the
critical GPS settings have been locked and cannot be
changed by the user. This is a security measure to
insure the GPS data is collected with the highest
accuracy and confidence.
J-2
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
The Data tab defines how the waypoints are collected and
how they are stored.
NE-FIA will record data that is the average of 180 individual
fixes.
The Data Exchange File, Export, Memory Exchange and
Keyboard wedge functions will be implemented at a future
date.
The Units tab is used to format the GPS data.
The critical settings that NE-FIA uses for Datum, Units,
Heading, Format, and Altitude Ref. are displayed on the
graphic to the left.
NE-FIA will use NAD27 CONUS (NEFG 2.0) or NAD83
(NEFG 3.0)
The Masks tab is used to set GPS signal masking
parameters when marking waypoints. Only the GPS
signals that meet the specified criteria will be used in the
waypoint averaging solution.
The critical settings that NE-FIA uses for Max PDOP,
Max EHE, DGPS, 3D Only, Min. Sat. Elevation, and Min.
Sat. SNR are displayed on the graphic to the left.
J-3
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
The HotKeys tab is used to assign an automatic function
to a specific button on the Allegro.
Currently, NE-FIA only uses the Insert key on the Allegro
to jump to the Mark Waypoint screen. The Insert Key
(Ins) Allegro on the can be pressed at anytime
LandMark CE is running and it will jump to the
collect waypoint screen.
The Keyboard tab is not used.
5.0 Wpt Screens
The Wpt screen is used to display, edit, manage and
collect GPS waypoints.
On the left side of the screen are the saved waypoints. A
default filename can be used (as shown) or a unique
name such as plot number, SP, PC, etc. To select a
waypoint, click on it.
The New button opens a screen where coordinates can
be entered.
The Edit button opens a saved waypoint. Here you can
change a waypoint name or apply a coordinate Offset.
The Del button is used to delete a previously select waypoint from the list. Waypoints can only be deleted
one at a time.
The Mark button is used to open the Mark Waypoint screen to start the averaging waypoint function.
Below the Mark button are the GPS details of the selected waypoint.
To average waypoints, press the Insert key (Ins) on the
Allegro keypad or click the Mark button in the Wpt
screen.
The top box displays the current, single fix GPS data.
Below the Current GPS is the default waypoint name
(editable) and a button to apply an Offset (distance,
direction, slope) to the averaged coordinates.
Next is a box that displays whether or not the current
GPS fix will be valid, based on the GPS masks set up in
the Cnf screen.
J-4
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
A Progress Bar appears when averaging to show the solution progress based on the number of fixes
indicated in the Cnf/Data screen. Below the status bar is the running average section displaying the
coordinates, elevation, PDOP and EHE.
To begin averaging, click the Average button. It will change and display the word “Averaging”. The
status bar will progress as valid fixes are used in the solution. When complete, the word “Averaging” will
change back to “Average”. During averaging, hold the GPS receiver stationary over the point until the
process is complete.
The information to be recorded on the tally sheet is located in the running average section of the screen
or you can click
Store WPT and view the data in the Wpt screen.
This screen shows that the Averaging process is
complete.
The Progress Bar is completely filled-in and the Average
box has changed from “Averaging” back to “Average”.
J-5
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
6.0 LandMark CE / EMTAC GPS FAQs
Q. My Allegro will not connect with the Laptop when using the cradle and USB to load LandMark
CE?
A. The COM Port on the Allegro may be set to COM 1 for data transfer with the Tally Program.
LandMark CE
can only be loaded through ActiveSync using the USB Port and cradle. See the first page of the
instructions in the LandMark CE Installation Guide. Be sure to set the Allegro COM Port back
to COM 1 after LandMark CE is installed.
Q.
I just installed LandMark CE on the Allegro, but the EMTAC isn’t communicating with the
Allegro?
A. The EMTAC GPS receiver must be turned on before LandMark CE is started. After LandMark
CE is installed on the Allegro, the COM Port in LandMark CE must be changed to match the Com
Port setting indicated during the Bluetooth GPS bonding process.
Q. My EMTAC was communicating fine with LandMark CE and then it just stopped and displayed
“No Comm. Act.”?
A. There has been some type of interruption in the Bluetooth signal between the EMTAC and
Allegro. On the Allegro, press the blue button and the F10 key to reconnect.
Q. The blue or green lights on my EMTAC quit working?
A Switch the EMTAC unit on and off until both lights are on.
Q. LandMark CE doesn’t always display that I am getting a “3D Diff” fix?
A. The EMTAC GPS receiver is capable of picking up two geostationary FAA satellites (WAAS) that
broadcast real- time, differential GPS corrections. The two WAAS satellites are positioned near
the equator over the Atlantic and Pacific Oceans. Based on your Latitude and view of the sky,
the EMTAC may be able to “see” these satellites. GPS fixes that are differentially corrected are
more accurate than a “3D Only” fix. The WAAS satellites are not displayed on the Skyplot when
using the EMTAC.
Q. I can’t change the critical settings in the Cnf screens?
A. The critical setting are locked to prevent the field user from changing them.
Q. I pressed the Insert key (Ins) on the Allegro, but LandMark CE won’t start Averaging?
A. The Ins key gets you to the Mark Screen, but you must click the box that shows “Average” to
begin Averaging.
Q. How do I calculate the coordinates of PC when using an offset from another location?
A. After averaging 180 fixes at the offset location on the Mark Screen, click Store WPT. Go to the
Wpt Screen and select the waypoint from the list that will get the Offset. Click the Edit button.
Click the Offset button and enter the distance, direction and slope (+ or -) to PC. Click OK. The
Show Offset box is checked and the Offset information is displayed in grayed-out font. When
done recording the Offset, click the Offset button and set the distance, direction and slope back to
“0”. Click OK. If you do not reset the Offset back to “0”, the Offset will still be applied for that
waypoint in the Wpt screen. The words “Offset ON” will be displayed when viewing the waypoint
details.
J-6
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
7.0 User Support
Any questions or problems can be directed to:
Rich McCullough
610-557-4081
rmccullough01@fs.fed.us
Forest Inventory and Analysis
USDA Forest Service
11 Campus Blvd, Suite 200
Newtown Square, PA 19073
J-7
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
J-8
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Appendix K. DOS TALLY and the PDRcon User’s Guide
1.0 Program Operation: DOS TALLY........................................................................................................ 1
1.0.1 Starting TALLY..................................................................................................................................... 2
1.1 TALLY Menu Item #1: Edit Plot............................................................................................................ 3
1.1.1 Data Entry ............................................................................................................................................ 3
1.1.2 Screen Messages ................................................................................................................................ 4
1.1.3 Navigation Keys ................................................................................................................................... 5
1.1.4 TALLY Pop-Up Menu ........................................................................................................................... 5
1.1.5 TALLY Help.......................................................................................................................................... 6
1.1.6 TALLY Error Reporting......................................................................................................................... 7
1.1.7 Recovering from a Program Crash ...................................................................................................... 7
1.2 TALLY Menu Item #2: (not in use) ....................................................................................................... 9
1.3 TALLY Menu Item #3: File Maintenance ............................................................................................. 9
1.3.1 Transfer Files ....................................................................................................................................... 9
1.3.2 Disk Directory..................................................................................................................................... 10
1.3.3 Delete Files ........................................................................................................................................ 10
1.4 TALLY Menu Item #4: QA/QC Menu .................................................................................................. 11
1.5 TALLY Menu Item #5: (not in use) ..................................................................................................... 11
1.6 TALLY Menu Item #6: State Menu ..................................................................................................... 11
1.7 TALLY Menu Item #8: Exit .................................................................................................................. 11
2.0 Program Operation: PDRcon ............................................................................................................ 11
2.0.1 Starting PDRcon ................................................................................................................................ 11
2.1 PDRcon Operation: ALLEGRO to PC............................................................................................... 12
2.1.1 Tallied Plot Files................................................................................................................................. 12
2.1.2 PA Regen Files .................................................................................................................................. 13
2.1.3 P3 Indicator Files ............................................................................................................................... 13
2.1.4 P3 Veg Data Files .............................................................................................................................. 13
2.1.5 TAPER Study Files ............................................................................................................................ 13
2.1.6 A Selected File ................................................................................................................................... 13
2.2 PDRcon Operation: PC to ALLEGRO............................................................................................... 13
2.2.1 TALLY Programs................................................................................................................................ 14
2.2.2 Parameter Files.................................................................................................................................. 14
2.2.3 Plot History Files ................................................................................................................................ 14
2.2.4 HISTGEN Library ............................................................................................................................... 15
2.2.5 A Selected File ................................................................................................................................... 15
2.3 PDRcon Operation: PC TALLY ......................................................................................................... 15
2.3.1 Tallied Plot Files................................................................................................................................. 15
2.3.2 Plot History Files ................................................................................................................................ 16
2.4 PDRcon Operation: PRINT RPT........................................................................................................ 16
2.5 PDRcon Operation: MAKE DISKS .................................................................................................... 18
2.6 PDRcon Operation: EXIT ................................................................................................................... 21
3.0 Reference.............................................................................................................................................. 21
3.1 What to do with Finished Plots.............................................................................................................. 22
3.2 How To: Transfer Files......................................................................................................................... 22
4.0 Troubleshooting .................................................................................................................................... 23
5.0 User Support ......................................................................................................................................... 25
1.0 Program Operation: DOS TALLY
This section of the Appendix K provides documentation on the operation of the DOS TALLY program on
the Allegro machine as it relates to the collection of FIA data for the Northeastern Research Station.
TALLY/PDRcon: K - 1
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Detailed instructions on how to transfer history files to and finished plot files from the Allegro are provided
in the next section, Program Operation: PDRcon.
1.0.1 Starting TALLY
Turn on the Allegro by pressing the [On/Off] button.
To launch the TALLY program:
•
•
•
If the TALLY program was active when the machine was last turned off, the TALLY program will
still be open and running. Simply continue where you left off.
If a PocketDOS window is open with a DOS prompt visible (C:\>), type FIA at the prompt to
launch the TALLY program.
If there are other windows open on the machine, close each window by clicking on the ⌧ in the
upper right corner of the window until you return to the desktop OR click the desktop button
in the bottom right corner of the screen. Open TALLY via Start/Programs/FIA/TALLY.
The first time that TALLY is launched, you may be prompted to confirm the current date. It is very
important that the Allegro system date and time is correct. If the date is not updated at this point, there is
another backup program that will warn you about the incorrect date once TALLY, HISTGEN or
LANDMARK is launched. It will prompt you to exit the program and reset the date and time. This can be
done by double-tapping the time stamp on the bottom status bar. Another utility called SetDate has been
added to ensure that the correct date and time is set on your Allegro after either a soft or warm boot.
After a warm or hard boot the utility is automatically launched. From the SetDate window either accept the
date/time or provide the correct date/time.
Unless TALLY had already been open and running when you last turned the machine off, the following
screen will be the first to appear:
TALLY/PDRcon: K - 2
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Enter the code for the state that you will be working in. For example, enter 36 for New York. The TALLY
Main Menu will then be displayed:
Enter the number corresponding to the menu item you wish to execute.
Once you are in the Main Menu screen, all actions are specific to the state code that you selected. If you
need to operate within another state, use menu item #6 to return to the State Menu to select the new
state. If you are completing a blind remeasurement plot, access the QA/QC Menu by entering menu item
#4.
1.1 TALLY Menu Item #1: Edit Plot
Selecting Edit Plot will allow you to begin entering data for a selected plot. Please keep in mind that
before you begin entering data for a plot, you must first download/transfer the history file for that plot onto
the Allegro. Instructions for this are provided under TALLY Menu Item #3: File Maintenance – Transfer
Files. An alternate means to update the Edit Plot list is by using the HISTGEN program that resides on
the Allegro. There are additional instructions for this program.
When you select Edit Plot, the plot selection menu will be displayed. The list of plots will only contain
those plots that were previously downloaded and that are currently present on the Allegro. Enter the
number preceding the file name to select that particular plot (see sample screen below). Note that if an
asterisk (*) appears after a selection number, data entry on that plot has either not been started, or has
been started but has not yet been completed. The absence of an asterisk (*) indicates that data entry for
that plot has been completed. To return to the Main Menu without selecting a plot, enter 00.
1.1.1 Data Entry
Once a plot has been selected, you will have to wait a minute or so until all of the plot’s data screens and
history data are loaded. Once the plot is fully loaded, the first data entry screen (Plot Level Data) will
TALLY/PDRcon: K - 3
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
appear. As you enter data, additional fields that require data entry may appear based on the value
entered in a specific field … you must enter a value for all visible fields.
TALLY’s data entry screens (menus) will appear in a specific order:
Plot Level Data
Condition Class Data
Subplot Data
Boundary Data
Seedling Data
Tree Data
GPS Data
Site Index Data
1 screen
1 to 9 screens
4 screens, 1 per subplot
0 to5 screens X 4 subplots
0 to n screens X 4 subplots
0 to n screens X 4 subplots
1 screen
0 to 5 screens
If you are ever confused as to which screen you are on, look at the message line at the top of the screen
… details of what screen you are on will be indicated there.
As you complete data entry for the last field on a screen, TALLY will automatically run an edit check on all
data entered for that screen. If an error is found, you will be presented with an error message and the
opportunity to correct the error. Otherwise, TALLY will automatically proceed to the next screen. For
some of the screen types (Boundary, Seedling, Tree), the number of required screens cannot be
predetermined by the program, so you must signal the program when you are finished. After you have
entered the last tree record, for example, the program will automatically present a blank screen for you to
continue entering tree data. To signal the program that you are finished entering tree records for the
current subplot, press the Menu Done key [M]. In the message line at the top of the screen, you will see
that TALLY is asking you to confirm that there is no data for this menu … press [Y] to continue to the next
screen type.
When you have completed entering data for all of the screens, the program will automatically perform a
check to ensure that all data has been completed. If all data is complete, TALLY will inform you as such
and ask if you wish to exit. Press [Y] to exit.
If at any point during data entry you would like to save the data entered to that point and exit the plot,
press [P] for Plot Done. TALLY will remind you that the plot is not complete, and will ask if you would like
to complete it now. To save any entered data and exit the plot, press [N]. To continue entering data in
the current plot file, press [Y].
1.1.2 Screen Messages
As mentioned, the top line of each screen is a message line that will provide you with important
information regarding data entry. For the most part, this message line will simply provide the details of
what screen you are on. For some of the screens there will be additional information, such as the last
tree number displayed in the right corner for the Tree screen. Occasionally, the screen information will be
TALLY/PDRcon: K - 4
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
temporarily replaced with other messages, such as an error message regarding the data item that was
just entered or a confirmation message to determine if you would like to continue with a particular action.
1.1.3 Navigation Keys
While entering data within the screens, there are several navigation keys that will allow you to perform
some actions out of the normal sequence (i.e. going back to a previous line) or to initiate an action such
as delete line or menu done. The following is a list of available navigation keys:
To display this screen listing key definitions from within the TALLY program, press the [F1] key. To close
this screen and return to data entry, press the [F1] key. A TALLY key cheat sheet is also provided that
can be taped to the Allegro for easy reference.
1.1.4 TALLY Pop-Up Menu
The TALLY program offers a number of helpful utilities, including calculator tools and plot diagrams.
These utilities are available via a menu that is displayed by pressing [T].
1. Horz. Distance – The Horizontal Distance tool calculates the horizontal distance based on specified
slope distance and percent slope values.
2. Slope Correction – The Slope Correction tool calculates the additional slope distance required to
reach a particular horizontal distance based on specified horizontal distance and percent slope
values.
3. Plot Layout – The Plot Layout utility will present a diagram of all boundary data for the current
subplot. If this utility is called from a screen that is not related to a particular subplot, the utility will
default to subplot 1.
TALLY/PDRcon: K - 5
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
4. Sweep Deduction – The Sweep Deduction tool calculates loss due to sweep based on specified
scaling diameter, log length (8 or 16 ft only), and absolute sweep values.
5. Tree Height – The Tree Height tool is currently unavailable.
6. Tree Location – The Tree Location utility will present a diagram of the location of the current tree
within a subplot. This utility must be called while on a tree record screen.
7. New Tree Locaton – The New Tree Location calculates the new location of a previously tallied
sapling on a microplot that is now a tree on the subplot.
8. Not in use.
9. Return – Selecting Return will close the Pop-Up menu and return you to your previous data entry
screen.
1.1.5 TALLY Help
Help is available for nearly every data entry field. Many of the help responses provide both a definition
and a list of legal entries. To display a help message, press the [K] while the cursor is in the data entry
field for which help is needed. To close the help screen and return to the data entry screen, either press
the [K] or simply begin entering the data value. The example that follows shows a typical help screen.
Note the arrows (
) that are displayed in the lower right corner that indicate the help message was too
large for a single screen … use the PDR’s Up and Down arrow keys to scroll the through the remainder of
the message.
The TALLY program also has a special help screen that defines the navigation and action keys used
throughout the program. To display this screen from within the TALLY program, press the [F1] key. To
close this screen and return to data entry, press the [F1] key.
TALLY/PDRcon: K - 6
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
1.1.6 TALLY Error Reporting
The TALLY program performs several types of error checking.
•
•
•
Data is checked for completeness … all data fields must be filled in and all re-measured trees
must be reconciled.
For data fields that must be populated with a code from a list of valid values, immediate checks
are performed to ensure that the entered value is valid.
Extensive logic checks are performed when a screen is complete and when Menu Done [M] is
pressed. These checks include the validation of the value entered in one field based on the
value(s) entered in one or more other fields.
When an error is detected, the cursor is returned to one of the data entry fields related to the error. If an
error is based on the relationship between data entered in several fields, the error may be in one of the
other associated fields rather than the one you are returned to. Enter the corrected data where
necessary and press Line Done [L] to continue.
In addition to error messages, the TALLY program will also display warning messages. Warnings will
Error Message – Logic Check
Error Message – Immediate Check
occur in situations where there is no defined rule that has been violated, but in which the conditions
suggest that the data input value be reconsidered before continuing on. The warning message generally
contains information to aid you in determining if the input data is correct.
1.1.7 Recovering from a Program Crash
As with any software program, there is always the possibility that something may go wrong. TALLY has
been designed in a manner that should avoid a loss of data in the event that something should go wrong.
If something should go wrong and you are thrown out of or forced to exit the program, TALLY’s first order
TALLY/PDRcon: K - 7
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
of business when you restart the program will be to attempt to recover any data that was being entered
when the problem occurred.
After you restart the TALLY program and select the state from the State Menu, TALLY should present you
with the following message:
Answer by pressing [N] if you DO NOT want to have TALLY recover any data that you may have entered
during your last session in the plot. Please keep in mind that you will lose any data entered from the time
the plot was entered up until the time that the program or system froze. It is highly unlikely that you would
ever want to refuse data recovery, and it is suggested that you think twice before answering with an N.
Answer by pressing [Y] if you would like to have TALLY recover any data that you may have entered
during your last session in the plot. Note that it is likely that the last line of data that was entered may not
be recovered.
When choosing to recover data, one of the most important things to realize is that when TALLY recovers
data, it will actually write the data to a new file that has an adjusted file name extension.
Please be sure to note this new file name, as both the old file and the new will appear in your list of
available plots for editing. The recovered data will only be available in the new file … this is the file you
should use from here on out.
TALLY/PDRcon: K - 8
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Once you have finished editing, transferring, and printing the plot under the new file name and have
confirmed that it contains the correct data, you should delete the original file from the Allegro using the
process described in TALLY Menu Item #3: File Maintenance – Delete Files
1.2 TALLY Menu Item #2: (not in use)
This menu item is not currently functional, and is reserved for future use. Selecting menu item #2 will not
trigger any action … the Main Menu will remain displayed until a different menu item is selected.
1.3 TALLY Menu Item #3: File Maintenance
Data stored on the Portable Data Recorder (PDR) is not permanent and can be lost if some catastrophic
event occurs. To avoid the loss of data, it must be transferred to a PC where it can be saved to a
permanent media such as disk or CD. Additionally, since data is stored in the PDR memory, it must be
managed to prevent memory overruns. Selecting File Maintenance will allow you to maintain data and
program files as necessary in support of these issues. When this item is selected, the following menu
screen is displayed:
1.3.1 Transfer Files
The Transfer Files option provides the ability to transfer files to and from the PDR. This includes data
files (initial plot history files and all completed plot data files), as well as program files (TALLY program
files and Parameter files).
Although this option is critical to the operation of the program on the PDR, its main function is to simply
establish a connection between the PDR and the PC. Once the connection is established, all file
transfers are controlled by the PDRcon program running on the PC. See PDRcon Operation: PC to
ALLEGRO and PDRcon Operation: ALLEGRO to PC for detailed instructions on the use of the PDRcon
program.
To establish the communications connection between the PDR and the PC when this option is selected,
TALLY will first instruct you to connect the PDR to a power supply and to connect the PDR to the PC via
a communications cable.
Power Supply: If you are using the Allegro cradle, simply seating the Allegro into the cradle will connect
the power supply. If you are not using the Allegro cradle, you will have to connect the power cable to the
top of the Allegro. Please note that it is critical to have the PDR connected to a power supply during data
transfer to prevent loss of data … if you attempt to perform the transfer while running on battery power
and the battery fails, data may be lost.
TALLY/PDRcon: K - 9
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Communications Cable: Whether or not you are using the Allegro cradle, you will need to connect the
serial cable (COM1) to the top of the Allegro. Be sure to connect the serial cable to the COM1 port …
connecting to COM2 will cause the process to fail.
Once you have connected the power supply and communications cable, press any numeric key as
directed. TALLY will then remind you that you will have to start the PDRcon program on the PC … press
any key as directed prior to starting PDRcon. The TALLY program will then indicate that it is waiting for a
connection.
When the transfer is complete, press [ESC] to return to the File Maintenance Menu.
1.3.2 Disk Directory
The Disk Directory option will provide you with the ability to display a list of all data files, program files,
and parameter files that currently exist on the machine.
1.3.3 Delete Files
The Delete Files function is provided to allow you to remove tallied plot data files from the PDR after they
have been transferred to the PC. This function does not apply to taper, P3 indicator or PA regen files.
These type of files are moved to a save directory on the Allegro when data files are transferred to the PC.
It is important that you use this function to delete a file only AFTER the file has been transferred to the PC
and printed for confirmation, otherwise the data will be lost.
NOTE … This is a very necessary function! The file that maintains the list of files on the PDR is limited to
25 file names per state due to memory restrictions. If this number is exceeded, the transfer process will
not work properly, and data files may be lost.
When this option is selected, the program will display (one at a time) the name of each file currently
loaded on the PDR along with a Y/N prompt. If you do not want to delete a specific file, respond by
pressing [N] … otherwise, press [Y] to delete the file. Once the program has presented each available
file, you will be prompted to confirm the deletion of any files to which you responded with a Y prior to the
execution of the delete action.
TALLY/PDRcon: K - 10
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
1.4 TALLY Menu Item #4: QA/QC Menu
The QA/QC Menu item provides for the collection of QA/QC data (i.e., blind remeasurement data).
Selecting this item will display a menu very similar to the Main Menu, and includes the following options:
Edit Plot, File Maintenance, and Enter Owner Data. If you have accidenTALLY entered the QA/QC menu
or have finished with QA/QC operations, press [4] to return to the TALLY Main Menu.
1.5 TALLY Menu Item #5: (not in use)
This menu item is not currently functional, and is reserved for future use. Selecting menu item #2 will not
trigger any action … the Main Menu will remain displayed until a different menu item is selected.
1.6 TALLY Menu Item #6: State Menu
The State Menu item provides a method for a return to the state selection screen. This is necessary in
the event that a crew will be crossing state lines, and thus must operate the TALLY program for more
than one state. Once you are in the Main Menu screen, all menu items selected are directed to a
specified state. In order to facilitate the ability to switch to a different state, the State Menu item will return
you to the list of states so that a new state may be selected.
1.7 TALLY Menu Item #8: Exit
The Exit menu item has been provided as a method to exit the TALLY program and return to a DOS
prompt. This item requires a password, and is designed to be used only under the guidance of the code
programmers at Newtown Square in order to resolve some issue or problem being experienced within the
program. Under a normal operating environment, there should be no need to exit the TALLY program …
it was designed to remain operational at all times.
2.0 Program Operation: PDRcon
This section of Appendix K provides documentation on the operation of the communications software that
resides on the PC and facilitates the transfer of data between the PDR and the PC.
2.0.1 Starting PDRcon
Start PDRcon by clicking on the PDRCON icon from the PC desktop in Windows. The PDRcon program
will start, and the initial menu screen will appear:
TALLY/PDRcon: K - 11
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
The colored buttons provide access to all available operations performed within the PDRcon program.
2.1 PDRcon Operation: ALLEGRO to PC
Clicking the ALLEGRO to PC button initiates operations for the transfer of files from the PDR to the PC.
Most file transfers of this type are to transfer completed plot files to the PC.
NOTE: Prior to executing any of the Allegro to PC options, you must have connected the PDR to the PC
and initiated the communication protocol on the PDR side. See TALLY Menu Item #3: File Maintenance
– Transfer Files for a full explanation of this.
2.1.1 Tallied Plot Files
The Tallied Plot Files option will be the most utilized option within this menu, and is used for transferring
completed TALLY plot files from the PDR to the PC.
When this option is selected, you will be prompted to first select the state for the files that you wish to
transfer, then the unit. After you have selected the appropriate state and unit, a list of all completed plots
that reside on the PDR that meet those criteria will be displayed … incomplete files will not appear on the
list. Click to select each file that you wish to transfer to the PC and press [OK]. Once PDRcon has
successfully transferred the files, you will receive a message noting how many files were transferred.
After transferring plot files to the PC, there are 3 additional actions that must be performed:
•
•
•
Print and confirm all transferred plot files (see PDRcon Operation: PRINT RPT)
Make backup and Newtown Square disks (see PDRcon Operation: MAKE DISKS)
Manually delete transferred plots from the PDR (see TALLY Menu Item #3: File Maintenance –
Delete Files) This action should only be done when all of the above steps have been
successfully completed.
TALLY/PDRcon: K - 12
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
A one page reference sheet of these actions, titled What to do with Finished Plots, is contained in the
Reference section at the end of this User’s Guide. Print it out and post it near your PC for easy
reference.
2.1.2 PA Regen Files
The PA Regen Files option is available for the transfer of completed PA Regen files. This is a special
study that is performed by the PA FIA crews, thus details of this option will not be discussed here.
2.1.3 P3 Indicator Files
The P3 Indicator Files option is available for the transfer of completed P3 Indicator files. This is a special
study that is performed by the P3 FIA crews, thus details of this option will not be discussed here.
2.1.4 P3 Veg Data Files
The P3 Veg Data Files option is available for the transfer of completed P3 Veg Data files. This is a
special study that is performed by the P3 veg FIA crews, thus details of this option will not be discussed
here.
2.1.5 TAPER Study Files
The TAPER Study Files option is available for the transfer of completed taper study files. This is a special
study that will not be performed by the regular FIA crews, thus details of this option will not be discussed
here.
2.1.6 A Selected File
The Selected File option has been provided as a tool for use only when a problem occurs. The use of
this option will not be explained in detail here, as it should be used only while in contact with your
Supervisor or Newtown Square personnel.
2.2 PDRcon Operation: PC to ALLEGRO
The PC to ALLEGRO button initiates operations for the transfer of files to the PDR. This includes
program files, parameter files, and plot history files.
TALLY/PDRcon: K - 13
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
NOTE: Prior to executing any of the PC to Allegro options, you must have connected the PDR to the PC
and initiated the communication protocol on the PDR side. See TALLY Menu Item #3: File Maintenance
– Transfer Files for a full explanation of this.
2.2.1 TALLY Programs
The TALLY Programs option provides the ability to transfer program update files to the PDR. When this
option is selected, the program will prompt you to insert the update disk containing the program files. It
may take several minutes for the files to transfer, even up to 5 minutes for some of the files when it
appears that nothing is happening … be patient. You will be notified when the transfer is complete.
During the transfer, you may be prompted for a course of action for certain situations. The specific
situation will be described in the message title bar, and buttons will be offered for you to indicate the
course of action. The following are those situations, and the course of action which you should indicate:
Situation
Files Have Same Size and Modification Date
Source File Is Newer Than Destination File
Source File is Older Than Destination File
Destination File Does Not Exist on Source
Course of Action
Transfer All
Transfer All
Transfer All
Skip All
Sample Prompt Message for Course of
2.2.2 Parameter Files
The Parameter Files option provides the ability to transfer new or updated parameter files to the PDR.
When this option is selected, the program will prompt you to insert the disk containing the parameter files.
It may take several minutes for the files to transfer … you will be notified when the transfer is complete.
2.2.3 Plot History Files
The Plot History Files option facilitates the transfer of history files to the PDR, and is required for each plot
that will be tallied.
When this option is selected, you will be prompted to first select the state for the files that you wish to
transfer, then the unit. After you have selected the appropriate state and unit, a list of all available history
data that meet those criteria will be displayed. Click to select each history file that you wish to transfer to
the PC and press [OK]. Once PDRcon has successfully transferred the files, you will receive a message
noting how many files were transferred.
Note: You must transfer any necessary history files to the PDR prior to heading out into the field or you
will be unable to open and access the plot. It is recommended that you transfer history files for all plots
expected to be completed for the current week, as well as a few planned for the following week just in
case your production rate is ahead of schedule. If HISTGEN is present on your Allegro, that program can
TALLY/PDRcon: K - 14
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
be used to load plots as needed. The reason is that the history files reside on the Allegro and therefore
are available at any time.
REMINDER … The file that maintains the list of files on the PDR is limited to 25 file names per state due
to memory restrictions. If this number is exceeded, the transfer process will not work properly, and data
files may be lost.
2.2.4 HISTGEN Library
The HISTGEN Library option has been provided as a tool to update the history files that reside on the
Allegro.
2.2.5 A Selected File
The Selected File option has been provided as a tool for use only when a problem occurs. The use of
this option will not be explained in detail here, as it should be used only while in contact with your
Supervisor or Newtown Square personnel.
2.3 PDRcon Operation: PC TALLY
The PC TALLY button presents operations for the transfer of files to and from a specific location on the
PC to be used by or produced from the PC based version of the TALLY program. This includes providing
plot history files as necessary for execution of the PC based TALLY program, as well as retrieving
completed plot and ownership files created with the PC based TALLY program.
2.3.1 Tallied Plot Files
The Tallied Plot Files option will allow you to “transfer” completed TALLY plot files from the PC based
TALLY program by converting and relocating them within the PC directory structure so that they are
available for the print and make disk functions of the PDRcon program. This option is essentially the
same as that described under PDRcon Operation: ALLEGRO to PC – Tallied Plot Files, with one
exception. Since the PC TALLY program resides on the PC itself, there is no need to initiate a
communication protocol prior to executing this transfer files option.
TALLY/PDRcon: K - 15
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
When this option is selected, you will be prompted to first select the state for the files that you wish to
transfer, then the unit. After you have selected the appropriate state and unit, a list of all completed plots
that reside on the PDR that meet those criteria will be displayed. Click to select each file that you wish to
transfer to the PC and press [OK]. Once PDRcon has successfully transferred the files, you will receive a
message noting how many files were transferred.
After transferring plot files to the PC, there are 3 additional actions that must be performed:\
•
•
•
Print and confirm all transferred plot files (see PDRcon Operation: PRINT RPT)
Make backup and Newtown Square disks (see PDRcon Operation: MAKE DISKS)
Manually delete transferred plots from the PDR (see TALLY Menu Item #3: File Maintenance –
Delete Files)
This action should only be done when all of the above steps have been successfully completed.
2.3.2 Plot History Files
The Plot History Files option facilitates the “transfer” of history files to the PC based TALLY program by
converting and relocating them within the PC directory structure. This is required for each plot that will be
tallied.
When this option is selected, you will be prompted to first select the state for the files that you wish to
transfer, then the unit. After you have selected the appropriate state and unit, a list of all available history
data that meet those criteria will be displayed. Click to select each history file that you wish to transfer to
the PC and press [OK]. Once PDRcon has successfully transferred the files, you will receive a message
noting how many files were transferred.
2.4 PDRcon Operation: PRINT RPT
The PRINT RPT button provides the ability to print reports for all transferred tallied plot files and other plot
files (i.e., PA Regen, P3 Indicator, and Taper). When this button is clicked, the following menu screen will
appear:
TALLY/PDRcon: K - 16
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Select the type of plot to print and the next window will appear. This window will direct you to the
directory where the data is stored on your C drive.
TALLY/PDRcon: K - 17
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
To print one or more plots:
•
•
•
•
Click the [Select Plot] button.
A directory window will appear.
Be sure that the directory window is pointing to the appropriate directory …
C:\PDRS\DATA\XX\ARCHIVE\ where XX is the state abbreviation.
Select one or more plot files that you wish to print … those selected will be highlighted.
To print your reports with double-spacing, click the [Double Space] button. This feature will likely only be
helpful for QA/QC.
Click one of the “Print On” buttons:
•
•
•
[Screen] to simply view the report(s) for the selected plot(s).
[Printer] to print the report(s) for the selected plot(s) to the default printer.
[Both] to view and print the report(s) for the selected plot(s).
For any of the “Print On” buttons selected, a report selection screen will appear.
Select one, some, or all of the available reports … all are selected by default.
Click [Continue] to proceed.
•
•
•
•
•
•
If Boundary data is available for any of the selected plots, you will be asked if you would like to
also print the Boundary report. Note that the Boundary report is only available when the report is
printed to the printer … it cannot be printed to the screen.
If you selected to print to the screen, the plot report will be displayed one page at a time.
Use the [Next Page] and [Prev Page] buttons to navigate through the report pages.
If viewing only a single plot, use the [Done] button to exit the on-screen view. If viewing multiple
plots, use the [Done] button to move to the next plot.
The [Cancel] button is available if you wish to change your selection of plot files for printing.
Click the [Close] button when finished to exit the print menu screen.
2.5 PDRcon Operation: MAKE DISKS
The MAKE DISKS button provides two options: 1) the ability to simultaneously create both backup disks
and Newtown Square disks; and 2) send plots electronically to Newtown Square. Prior to executing
either operation, the plot should be printed and confirmed.
TALLY/PDRcon: K - 18
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Upon selecting the operation Via Diskette, a screen will appear informing you that you will need two
floppy disks … one is for your site backup and the other is for sending your electronic files to the
Newtown Square office.
You can continue to re-use these disks until they are full, however, it is requested that you send in your
Newtown Square disk at the end of each month. At that time, you should label the corresponding backup
disk to match the label on the Newtown Square disk, and place the backup disk in a safe storage place.
When you begin a new Newtown Square disk, you will also begin a new backup disk.
If you are running low on disks, please contact someone at Newtown Square … we will be happy to send
more to you!
When you are ready to begin the make disks operation:
Click the [Continue] button.
•
•
•
•
•
•
•
•
Select the type of file.
You will be prompted to provide the drive letter … Use A if you are writing to a floppy disk.
Next, you will be asked for the state abbreviation of the files that you will be writing to the disk …
please keep in mind that this is the state abbreviation (i.e. PA) not the state code.
If there are no completed files available for the specified state, you will get a message indicating
as such, and the process will be terminated.
If there are completed files, you will be prompted to select those files you wish to transfer from a
list of available files. You may select more than one plot to transfer … those selected will be
highlighted.
Click [OK].
Insert the Backup disk when prompted … you will get a message when the files have been
successfully copied to the disk.
Insert the Newtown Square disk when prompted … you will get a message when the files have
been successfully copied to the disk.
Be sure to make a listing of all files being included on the Newtown Square disk and send it along with the
disk. A standard transfer sheet is available for this task … if you do not have a sheet or have any
questions regarding how to fill it out, please contact your Supervisor.
After you have successfully copied the files to the Backup and Newtown Square disks, the files will be
automatically removed from the list of completed plots.
Upon selecting the operation Electronically, the following screen appears after you click [Continue]
button.
TALLY/PDRcon: K - 19
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
When you are ready to begin the process to send plots electronically:
•
Select ZIP AND E-MAIL PLOTS.
From the following screen select the type of plot to send and click [Go].
If there are no completed files available for the specified state, you will get a message indicating as such,
and the process will be terminated. If there are completed files, you will be prompted to select your duty
station from a drop down list. As soon as the duty station is selected, the program automatically zips the
file to be transferred and notifies you that PDR Transfer Sheet has been created. This transfer sheet is
appended to the zip file.
TALLY/PDRcon: K - 20
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Insert the Backup disk when prompted … you will get a message when the files have been successfully
copied to the disk.
When the process is complete you will get a message saying that “Plots Have Been Successfully EMailed.” Note: This plot is sent immediately if you are connected to the network via dial-up or VPN and
have Lotus Notes open. If not, it will be sent the next time you connect and open Lotus Notes.
If the plots sent were P2 plot files, the next step is to “CLEAN-UP PRINT FILES.” This process moves the
P2 plot files from the Archive to the Done directory in c:/PDRS/DATA/state.
If you suspect a problem when sending your files the first time, you can “RESEND PLOT FILES.” The
program will prompt you to enter your duty station; from there it will bring up all of the zip files that has
been created using the electronic plot send utility. The program will prompt you to select the zip file to
resend and the associated text file. Once both have been selected, the files will be resent to Newtown
Square.
2.6 PDRcon Operation: EXIT
Clicking the EXIT button terminates communication with the PDR and ends the PDRcon program.
3.0 Reference
In order to provide a way to quickly present you with the general steps required to perform some selected
tasks, the following reference sheets have been developed. It will be helpful to print these reference
sheets and post them near your PC.
TALLY/PDRcon: K - 21
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
3.1 What to do with Finished Plots
1. Transfer Plots
from the Allegro to the PC using PDRcon
2. Print and Confirm
all transferred plots using PDRcon
3. Make Backup & FIA disks
using PDRcon
4. Manually delete transferred plots
from the Allegro
This should only be done when all 3 of the above steps have been successfully completed!
3.2 How To: Transfer Files
1. Connect Power & Serial Communications Cable to the Allegro
2. Initiate Communications from the Allegro
3. Select File Maintenance from the Main Menu
4. Select Transfer Files from the File Maintenance Menu
5. Ensure that power and communications cables are connected, and press any numeric key
6. Press any numeric key and look for the “Waiting for Connection” message
7. Initiate Communications from the PC
8. Open PDRcon
9. Make sure the Allegro radio button is selected
10. Click either on the Allegro to PC or PC to Allegro button, depending on whether you are transferring
files to or from the Allegro
11. Click on a sub-menu button for the desired transfer action
12. Select files as prompted
13. After receiving a message (on the PC) that the file(s) were transferred successfully, press [ESC] on
the Allegro to end the Communications link
14. If completed plots were transferred from the Allegro to the PC, remember that you must also follow
the steps of “What to do with Finished Plots” … Print and Confirm; Make Backup & FIA Disks;
Manually Delete Transferred Files
TALLY/PDRcon: K - 22
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
4.0 Troubleshooting
This section has been provided in an effort to address some questions or problems that are likely to arise
in the use of the DOS TALLY program on the Allegro. This section is in no way all inclusive. Please
contact the Newtown Square office with any problems that you may have … if you are having the
problem, then it is likely that someone else may be as well, so problem reporting and resolution will be of
benefit to all.
Problem:
I was working in TALLY, and the program seems to have frozen up. No matter what key I hit,
the machine just beeps and nothing happens.
Resolution:
First, try using the [On/Off] button to turn the machine off and then turn it back on again. If this does not
solve the problem, you’ll have to close and restart TALLY by following these steps:
If your Allegro TouchScreen is disabled, you’ll need to enable it by pressing the Blue [
] key and then
pressing the [BkSp] key.
Close the DOS window that is running TALLY by using your stylus to click on the ⌧ in the bottom right
corner of the screen.
When asked what you want PocketDOS to do … select Shutdown from the drop-down list and click [OK].
The DOS window and TALLY should then close, and you should be looking at the Desktop. If you do not
see the Desktop and the TALLY launch icon … click the Desktop button
in the bottom right corner of
the screen.
From the Desktop, double click on the TALLY icon to launch the TALLY program.
After you select the state from the State Menu, TALLY should present you with the following message:
Answer by pressing [N] if you DO NOT want to have TALLY recover any data that you may have entered
during your last session in the plot. Please keep in mind that you will lose any data entered from the time
the plot was entered up until the time that the program or system froze.
Answer by pressing [Y] if you would like to have TALLY recover any data that you may have entered
during your last session in the plot. Note that it is possible that the last line of data that was entered may
not be recovered.
Please note that when TALLY recovers data, it will actually write the data to a new file that has an
adjusted file name extension.
TALLY/PDRcon: K - 23
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Please be sure to note this new file name, as both the old file and the new will appear in your list of
available plots for editing. The recovered data will only be available in the new file … this is the file you
should use from here on out.
Once you have finished editing, transferring, and printing the plot under the new file name and have
confirmed that it contains the correct data, you should delete the original file from the Allegro using the
process described in TALLY Menu Item #3: File Maintenance – Delete Files.
Once you have successfully recovered your plot file, it would be wise to disable your Allegro
TouchScreen again by pressing the Blue [
] key and then pressing the [BkSp] key.
Problem:
The Allegro itself seems to have frozen. Nothing happens when I press a key or when I click on
the touchscreen.
Resolution:
In this situation, you will need to reset the machine. To do so, hold down the [On/Off] key for more than
eight seconds. The machine will then blank out and a “Warm Boot” message will appear … you can
release the [On/Off] button when you see this message. Within a few seconds, your machine will reset
and the regular Desktop will appear.
Please keep in mind that when a reset is performed, all running applications are closed and data may be
lost. When you restart TALLY, the program should engage it’s recovery feature and try to recover the plot
you had been working in, but remember that this may not include the last line or so that had been
entered.
Problem:
I was trying to transfer files to or from the Allegro, but keep getting a script error message that
indicates the program is not connecting.
Resolution:
The message will likely tell you to click [OK]. When you do so, the following FastLynx screen should
appear:
TALLY/PDRcon: K - 24
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Make sure the Connect as client radio button is selected, then close the window using the ⌧ in the upper
right corner.
FastLynx will then try to connect again. If you get the message again, you will need to consider whether
or not you saw the Waiting for Connection message on the Allegro BEFORE you initiated the connection
through PDRcon. If you did not, or cannot recall, try starting over … performing steps out of order will
hinder the connection.
5.0 User Support
Any questions or problems can be directed to:
Steve Evans
Mary Miller
610-557-4063 610-557-4046
swevans@fs.fed.us
marymiller@fs.fed.us
Forest Inventory and Analysis
USDA Forest Service
11 Campus Blvd, Suite 200
Newtown Square, PA 19073
TALLY/PDRcon: K - 25
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
TALLY/PDRcon: K - 26
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Appendix K. HISTGEN: History File Generation Program on the PDR
1.0 Program Description ............................................................................................................................. 27
2.0 Program Operations.............................................................................................................................. 28
2.1 Using the Allegro Touch Screen or Keyboard................................................................................... 28
3.0 Operating HISTGEN ............................................................................................................................. 28
3.1 Program Activation ............................................................................................................................ 28
3.2 Using HISTGEN Help ........................................................................................................................ 28
3.3 Selecting a State ............................................................................................................................... 29
3.4 Selecting a Unit ................................................................................................................................. 29
3.5 Selecting Plots................................................................................................................................... 30
3.6 Adding New Plots to the Plot History Database ................................................................................ 32
3.7 Viewing Current Software Versions................................................................................................... 35
3.8 Exiting HISTGEN............................................................................................................................... 35
4.0 User Support ......................................................................................................................................... 36
1.0 Program Description
HISTGEN is created to provide, on the Allegro, some of the same functionality as currently exists within
the PC based PDRCON program. The functionality that HISTGEN provides is:
The ability to create skeletal plot files from the plot history database that are compatible with TALLY.
The ability to manually add new plot history records to the database. This new functionality does not exist
with PDRCON.
HISTGEN eliminates the need to connect the ALLEGRO to the PC for the purpose of creating plot history
files for use with TALLY. Plot history files can be created in the field at the plot site or en route to the plot
site.
HISTGEN does not allow the user to print reports or create media for data backup or data transmittal to
Newtown Square. These functions must be performed by the PC base PDRCON program. PDRCON
can still be used to generate plot history files if preferred.
HISTGEN: K - 27
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
2.0 Program Operations
2.1 Using the Allegro Touch Screen or Keyboard
HISTGEN is designed for use with the Allegro keys and/or the touch screen for navigation and selection
of displayed objects. Touch screen selection requires that the user touch or tap the screen area over the
item to be selected. This action is the same as pointing and clicking with the PC mouse. Most selections
only require a single tap or click; however selection of the state from the State Menu requires double
tapping or clicking.
When the Allegro touch screen is not active navigation around the HISTGEN menus and lists is
accomplished with the arrow keys or the tab keys. Selection of an item after navigation to that item is by
pressing the ENTER key. Note that the arrow keys are used to navigate to items within the same menu
or items in a list of items. The tab keys are used to navigate to buttons in the program window.
Throughout the rest of this document, operating instructions will be presented for operations using the
Allegro keyboard because this method requires the most definition. Keep in mind that the touch screen
method is available.
3.0 Operating HISTGEN
3.1 Program Activation
With the Allegro desktop displayed:
1. Use the arrow keys to highlight the HISTGEN logo
2. Press [ENTER] to select
When activated, the program first displays a spinning hourglass while loading. The Forest Service Shield
is then displayed for about four seconds while the programs initializes. The State Selection Menu is then
displayed. This menu is very similar to the PDRCON menu.
3.2 Using HISTGEN Help
Please note that a small menu bar is present at the upper left of the HISTGEN window. The second menu
selection is the Help option. It will always appear in the same place on the menu bar. Select this button
to display the program help screens. To select this option press the [Alt] key to highlight the menu "File"
option. Then press the Right Arrow key, to highlight "Help", then press the Down Arrow to highlight
"Show" and [ENTER] for Help. Pressing the [F1] key is the same as selecting the Help option. Another
way to show Help is to hold down the [Ctrl] key and press "H". When Help is displayed, selecting the
HISTGEN: K - 28
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Help option again will return to the normal HISTGEN display. Press the [TAB] key to highlight the
[PREVIOUS] and [NEXT] buttons, and then press ENTER to navigate around the Help display screens.
3.3 Selecting a State
To select the appropriate state:
1. Press the Right Arrow to advance the highlight to the desired state.
2. Press [ENTER] to select the highlighted state.
Once the correct state is selected, the selection is used for the rest of the program session to filter the
data in the plot history database to reduce operating time.
The Unit Selection Menu is then displayed. Only those units that are valid for the selected stated are
shown in the menu. Note: Double click the state to select it when using touch screen.
3.4 Selecting a Unit
To select a Unit:
1. Press the Up Arrow or Down Arrow to highlight the appropriate Unit.
2. Press [ENTER] to select the highlighted Unit.
HISTGEN: K - 29
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Selecting the appropriate Unit begins the database search for all plot records that match the State and
Unit criteria. During this search a progress display is presented.
When all plot records have been found and added to the Plot List, the Plot Selection list is displayed. The
number of entries in the list varies upon the size of the unit and the amount of forest land; i.e. number of
history trees that exist within the Unit.
3.5 Selecting Plots
Multiple selections can be made from the Plot Selection List. Do not select more plots than can be tallied
in one week (max. 15). An alternative is to load plots on a daily basis. This will help to reduce the number
of uncompleted plots that TALLY displays.
To select plots:
1.
2.
3.
4.
5.
Press the UP Arrow and Down Arrow to highlight the desired plot.
Press [ENTER] to select the highlighted plot.
Repeat steps 1 and 2 until all desired plots are selected.
Press the [TAB] key until the [ADD] button is highlighted.
Press [ENTER] to continue.
HISTGEN: K - 30
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Before the plot build process is started, a scan of the TALLY partition is performed to see if any
completed plot files are available for transfer to the PC. When the scan is completed a message is
displayed so the user knows of their existence so they can be transferred to the PC at a later time.
Press [ENTER] once or twice to acknowledge this message.
While the plot history files are being constructed, a text message box is displayed to show the progress of
the process.
HISTGEN: K - 31
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
After all plot files are created they are transferred to the TALLY partition. The appropriate file containing
the names of all plots available for TALLY is updated to reflect the additions. The completion message is
displayed.
Press [ENTER] to acknowledge this message and HISTGEN will terminate. After HISTGEN has
terminated it is now possible to open TALLY and begin collecting data.
3.6 Adding New Plots to the Plot History Database
Occasionally, a new plot history record may have to be added to the Plot History database. This need
may arise because an alternate plot has been named to replace an existing plot, or because a plot was
inadvertently omitted when the plot database was created.
To add a new plot data record, perform the following sequence.
1. Select the appropriate state from the State Menu.
2. Select the appropriate unit from the Unit Menu
When the Plot Selection List is displayed:
3. Press the [TAB] key to highlight the [New] button.
4. Press [ENTER].
HISTGEN: K - 32
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Note: Do not select [New] if no new plot information is available from Newtown Square.
In response to the [New] button being selected a message is displayed that confirms that HISTGEN is
ready to enter the functionality that creates a new plot history record in the database. Press [ENTER] to
acknowledge the message.
HISTGEN then displays the Plot History Data Entry window. This window contains several text input
boxes for the data fields that are required to create a plot data record.
HISTGEN: K - 33
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Enter the appropriate data into each text input box as follows:
1. Hold down [Alt] and press Right Arrow to advance to the next text entry box. In most cases using
the [Alt] + Right Arrow is not needed because as each box is completed the cursor automatically
advances to the next text entry box.
2. Enter the appropriate data into the current text entry box. Each box will only allow the correct
number of characters to be entered. The large text box at the bottom of the window provides
some information as to the data required for the current text input box. As data is entered into a
text input box, the box inverts colors to indicate that the data has been accepted. Boxes will autofill based on the sample kind entered.
3. After all data has been entered, press [TAB] to highlight the [Submit] button.
4. Press [ENTER] to create the new plot history data record.
While the new plot history file is being added, a text message box is displayed to show the progress of
the process. This may take several minutes.
HISTGEN: K - 34
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
After the new record has been added to the database, the database is then scanned and the updated Plot
Selection List is displayed to allow selection of the new plot. Return to Section 3.5 instructions to select
this plot.
3.7 Viewing Current Software Versions
The third menu bar option is labeled "Versions". The Versions option is selected by pressing the [Alt] key,
then press the Right Arrow to highlight "Versions", then the Down Arrow to highlight "Show" and press
[Enter]. When selected, the Versions option displays a message which contains the names of the
software elements and their current version number. Please note that the version of the software that
does not reside on the Allegro (PDRCON and PLOT5) may not always be current. Press [ENTER] to
respond to the versions message. Versions can also be displayed by holding down the [Ctrl] key and
pressing [V].
3.8 Exiting HISTGEN
There are two ways to exit HISTGEN. The first way is to select "Exit" from the menu bar. Press [Alt] to
highlight the "File", "Exit" option. Then press [ENTER]. HISTGEN will exit at once.
The second way to exit the program is to press[Esc]. HISTGEN will display the message "End the
Program?". Respond with [Y] to exit, or [N] to continue. You can also exit the program by holding down
the [Ctrl] key and pressing "X".
HISTGEN: K - 35
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
4.0 User Support
Any questions or problems can be directed to:
Steve Evans
610-557-4063
swevans@fs.fed.us
Forest Inventory and Analysis
USDA Forest Service
11 Campus Blvd, Suite 200
Newtown Square, PA 19073
HISTGEN: K - 36
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Appendix K. Allegro CE Owner’s Manual
Introduction ................................................................................................................................................. 38
Keyboard: Special Keys and Key Sequences............................................................................................ 38
Blue Shift Key Usage .................................................................................................................................. 38
Gold Shift Key Usage.................................................................................................................................. 38
Circular Key Usage ..................................................................................................................................... 38
Shifted Options............................................................................................................................................ 39
Keyboard Options ....................................................................................................................................... 39
Cleaning the Keyboard................................................................................................................................ 40
Touchscreen Display................................................................................................................................... 41
Touchscreen Operation............................................................................................................................... 41
Adjusting the Display................................................................................................................................... 41
Cleaning the Touchscreen .......................................................................................................................... 41
Screen Protector Application....................................................................................................................... 42
Calibration ................................................................................................................................................... 42
System Tray Indicators ............................................................................................................................... 43
Batteries ...................................................................................................................................................... 43
Changing the Battery Pack ......................................................................................................................... 43
Setting Battery Charge (only for NiMH batteries)........................................................................................ 44
Battery Life .................................................................................................................................................. 45
Battery Status Icons .................................................................................................................................... 45
When the Battery Voltage Drops ................................................................................................................ 45
Power Management Options ...................................................................................................................... 46
Recharging the NiMH Battery Pack ............................................................................................................ 46
Charging Options ........................................................................................................................................ 46
Spare NiMH Battery Packs ......................................................................................................................... 48
Battery Gauging Explained ......................................................................................................................... 48
Storing the Allegro CE During Inactive Periods .......................................................................................... 49
Short-Term Backup Power Supply.............................................................................................................. 50
Date/Time.................................................................................................................................................... 50
Display......................................................................................................................................................... 51
Keyboard ..................................................................................................................................................... 52
Owner.......................................................................................................................................................... 53
Communication ........................................................................................................................................... 53
Power .......................................................................................................................................................... 55
Stylus........................................................................................................................................................... 56
Volume and Sounds.................................................................................................................................... 57
ActiveSync Connection ............................................................................................................................... 58
ActiveSync Troubleshooting........................................................................................................................ 62
Allegro CE Owner’s Manual: K -37
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Introduction
The following is a quick reference guide for field crews. This is an abridged version for the USDA Forest
Service, Forest Inventory and Analysis. Note: The original source for this document was from the Pacific
Northwest FIA unit. Text and illustrations have been modified for the Northeast.
Keyboard: Special Keys and Key Sequences
The standard keyboard letters, numbers, and functions are printed in dark brown on the off-white keys
and in off-white on the dark brown keys. These standard options are operational unless a GOLD or BLUE
shift key is pressed.
Blue Shift Key Usage
To access the keyboard characters printed in blue, press and release the BLUE shift key followed by the
key with the desired blue-lettered character. To activate several blue-lettered keys before returning to
standard mode, continue to hold the BLUE shift key down while you press the desired keys. Once the
BLUE shift key is released, the keyboard reverts back to the standard mode.
Gold Shift Key Usage
To access the gold shift key options, press and release the GOLD shift key followed by the key with the
desired gold symbol. To activate several gold-lettered options before returning to standard mode,
continue to hold the GOLD shift key down while you press the desired keys. Once the GOLD shift key is
released, the keyboard reverts back to the standard mode.
Circular Key Usage
The circular key located in the center of the keyboard has two functions:
1) Standard (no shift keys): Up, Down, Right, and Left arrow keys
2) BLUE shifted functions: Page Up, Page Down, Home, and End
Allegro CE Owner’s Manual: K - 38
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Shifted Options
The shifted options and the associated key sequences are listed below.
Option
Function keys F6, F7, F8, F9 and F10
Function keys F11 and F12
Enable/Disable touchscreen
View Windows CE Start Menu
Page up
Page down
End
Home
Toggle caps lock on and off
Toggle display backlight
Display Contrast Lighten
Display Contrast Darken
Perform a reset
Key Sequence
BLUE key + desired function key
GOLD key + desired function key
BLUE key + TS
BLUE key + Start
BLUE key + PgUp
BLUE key + PgDn
BLUE key + End
BLUE key + Home
BLUE key + CapLk
GOLD key + F3 (see gold light bulb symbol above
function key)
GOLD key + F4 (see gold symbol above function
key)
GOLD key + F5 (see gold symbol above function
key)
On/Off (hold down for eight seconds)
Keyboard Options
The following keys and key sequences are functional in Windows CE.
On/Off (Reset)
This key is used to turn the Allegro on and off. The ridge around the key helps prevent the
Allegro from being accidentally turned on without your knowledge (while it is in a backpack,
for example). A reset is performed by holding down the On/Off key for about eight seconds.
Release the key when the reset process begins.
Contrast Keys
To make the display darker, press the GOLD key and the F5
key. To make the display lighter, press the GOLD key and the
F4 key.
Backlight On/Off
The backlight is toggled on and off by pressing the GOLD key and the F3 key.
Tab, Forward and Backward
The tab keys are used primarily for cursor movement between fields.
Allegro CE Owner’s Manual: K - 39
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Touchscreen Disable/Enable
The touchscreen key allows you to disable and enable the touchscreen. This
feature allows you to wipe off the screen without inadvertently making selections
on the screen. Press the BLUE shift key and the TS key to disable the screen. A
system tray icon will appear showing that the touch screen has been disabled.
Once the screen has been cleaned, use the same key sequence to enable the
touchscreen. (For instructions on how to clean the screen, refer to Display, Touchscreen later in this
chapter.)
Task Manager
Press the Task Manager key to view all of the programs that are currently running. Select
which program you want to be in by using the up and down arrow keys to highlight the
desired program and pressing Enter.
Start Menu
Press the BLUE shift key and the Start key to view the Windows CE Start
Menu. Use the arrow keys to move up and down the menu. Press the Enter
key to make your selection.
The Task Manager and Start Menu functions have been provided to speed up operation. You do not have
to use the touchscreen and stylus to bring up the Start Menu or to change tasks. These keys are also
handy when the Taskbar has been hidden.
Right Mouse Click
+ Tap
Press the Alt key and touch the screen with a stylus to achieve a right mouse click. In many
Windows CE programs, when you right click on an item a menu is displayed listing functions and options
that pertain to the item.
Cleaning the Keyboard
Dirt and debris can get underneath the keyboard bezel. To clean, use a coin (do not use a screwdriver) to
pull the bezel up at the recess located at the bottom of the keyboard and remove it. We recommend that
you use warm water, mild detergent, and a toothbrush to clean the keyboard or simply brush it out. The
Allegro remains sealed during this process. (Do not direct a high pressure stream of water at the
keyboard to clean it. This action could break the seal, causing water to get inside the Allegro.)
Allegro CE Owner’s Manual: K - 40
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Reattach the bezel by carefully inserting the top ridge under the function keys and lowering the bezel
down flat onto the case. Press down along the sides while aligning the keys through the holes.
Note: After you reattach the bezel, check each key to make sure it is completely free from the bezel. If
any part of a key is caught underneath the bezel, you may not be able to turn the Allegro on or you may
hear a continuous string of beeps.
Touchscreen Display
The display has a touchscreen used to activate programs in Windows CE and to make selections. The
touchscreen works similar to a mouse. Three styli are provided: two small on-board stylus that snaps into
a holding bay built into the top of the case and a full size pen-type stylus. Other pointed objects can be
used, including your finger. Be sure to use a device that will not SCRATCH the screen. Screen
protectors can help extend the life of your screen—please use them!
Touchscreen Operation
Use the following techniques to operate the touchscreen:
•
•
•
•
Touch the screen at the desired location, just as you would point and click with a mouse.
Tap on the screen once to achieve a single click or twice to achieve a double-click.
A right mouse click is accomplished by holding down the Alt key and tapping the screen.
Drag and drop items by touching and holding the item on the screen, dragging the stylus to the
desired location, and removing the pointing device from the screen.
Adjusting the Display
The display features can be enabled, disabled, or controlled through the Control Panel (see Chapter 4).
Some display features can be adjusted using the special key sequences shown below:
Display Function
Backlight Toggle On and Off
Increase contrast
Decrease contrast
Key Sequence
GOLD key + F3 (see gold light bulb symbol above
function key)
GOLD key + F4 (see gold symbol above function
key)
GOLD key + F5 (see gold symbol above function
key)
Contrast and Automatic Temperature Compensation
Once you have set the contrast, you seldom need to readjust it.
Backlight
The display backlight is used to enhance visibility in low-light conditions in the field. The backlight can
enhance visibility indoors. The brightness of the display backlight is adjustable from dim to bright (the
default). This adjustment is made from the Control Panel|Display Properties|Backlight. Note: The
brighter the backlight is adjusted, the more power consumed which shortens battery life.
Cleaning the Touchscreen
Disable the touchscreen before you wipe it off or clean it to avoid inadvertently making selections on the
screen (see instructions below). Use a clean cotton cloth to gently wipe off the screen. Do not use
anything abrasive that could scratch the screen (including paper products such as tissues and paper
towels).
Note: Petroleum-based cleaners and solvents are not be used. They can damage polycarbonate.
Allegro CE Owner’s Manual: K - 41
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Touchscreen Disable/Enable Key
The touchscreen key disables and enables the touchscreen. Press the BLUE shift key And the TS key to
disable the screen. Once the screen has been cleaned, use the same key sequence to enable the
touchscreen.
Screen Protector Application
Screen protectors are very important for protecting the screen in field situations and especially during
transport in your backpack. Be sure to clean the Allegro screen as indicated in the previous section
before applying a screen protector.
To apply a screen protector to the Allegro screen, begin to remove the backing to expose the adhesive
along the entire top (wide) edge of the screen protector. Align the exposed adhesive along this edge with
the top of the Allegro screen. Then without placing any pressure on the screen protector yet, remove the
rest of the backing and place the entire protector gently on Allegro screen.
Next, align the long edge of a credit card (with a smooth edge) to the wide portion of the Allegro screen,
and working from the center of the screen, work any bubbles or air pockets from the center to the top of
the screen. Repeat this procedure working from the center to the bottom of the screen.
If you need additional screen protectors, contact Newtown Square.
Calibration
If you have trouble selecting an item when you tap on it, the touchscreen may need to be calibrated
through User Control Panel|Stylus. Please see instructions for this under the heading User Control Panel
Options (in Windows CE.NET) - Stylus.
Allegro CE Owner’s Manual: K - 42
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
System Tray Indicators
System tray indicators specify applications that are running on your computer. The Allegro CE system
tray indicators are located in the bottom right corner system tray. These system tray indicators are active
while the Allegro is running specific tasks and provide you with the following information:
System Tray
Icon
Indicators Description
Remaining Battery Charge Status: shows the approximate percent of
charge remaining in the batteries
External Power Input: indicates that you are connected to an external
power source and not drawing power from the internal batteries
Charging Indicator: appears in the system tray while the rechargeable
batteries are being charged up
Data Storage Activity: appears when data are being read from or written
to the solid state disk
PC Card Activity: indicates that the application program is accessing the
PC card (do not remove the card when this icon is on)
Caps Lock On: appears when the all capital letters option is activated
Touchscreen Disable: appears when the touchscreen is disabled for
cleaning purposes, or for use in heavy rain storms.
PC Connection: appears when there is an active connection between
the Allegro and the desktop PC.
Batteries
Changing the Battery Pack
The battery compartment is accessed through a door in the back of the case. Before you remove an
existing battery pack from the Allegro, complete the following:
1. Exit from all open programs.
2. Turn the Allegro off.
3. Push up on the sliding latches on the sides of the Allegro to open the battery compartment door.
. The door will pop open.
4. Slide the battery pack (alkaline holder or NiMH pack) towards the left side of the battery
compartment and pull it out.
If using the alkaline battery holder, also complete steps a – c below to replace the alkaline
batteries…
Allegro CE Owner’s Manual: K - 43
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
a. Open the door to the alkaline battery holder by pressing in on both tabs with your index
finger and thumb as shown
.
b. Insert three fresh AA alkaline batteries, taking care to orient them correctly (only use
alkaline batteries). Always replace all three batteries at once.
c. Slide the door to the alkaline holder back into place, making sure it snaps securely shut.
5. Place the new NiMH battery pack with writing upside down (or alkaline battery holder with
“Alkaline Battery Holder 12449” sticker to the left) in the left side of the battery compartment. Put
gentle pressure on the battery pack (or holder) while sliding it all the way to the right. The ► on
the battery should line up with the ► inside the case.
6. Push the battery door closed, squeezing each of the bottom two corners of the battery door/unit
until each latch clicks into place. The latches should automatically lock the door into place and
seal the compartment. Make sure that the slide latches have slid completely downward to
securely close the door.
7. Occasionally check the battery task tray indicators on the Allegro display while you are using the
Allegro. When the battery power gets low, replace the alkaline batteries or insert a NiMH pack.
Setting Battery Charge (only for NiMH batteries)
When using alkaline batteries, the Allegro can read the charge percent automatically after a few minutes.
However, after installing a NiMH battery pack into the Allegro, the battery charge percent must be set.
This allows the Allegro to know the pack’s charge status. When you insert the battery pack into the
Allegro for the first time, the charge status is unknown to the Allegro and you will be prompted for this
information.
To set the charge status of the battery pack after you install the battery:
1. Turn on the Allegro by pushing the On/Off button. As Windows CE loads, various screens appear
that do not require any action until it gets to the New Battery Detected screen.
2. Tap on the circle next to the Specify charge (%) option to set charge status.
3. If you just placed a fully charged NiMH battery into the Allegro’s battery compartment, set the
charge percent to 100 by tapping on the small up or down arrows to move the percent. If this is
not a fully charged battery, enter the approximate percentage of charge it contains. If you do not
know what the charge status of the battery is, we recommend that you set the charge value to
10%.
4. Set the capacity of the battery:
NiMH by GP Batteries (shipped w/Allegro): 3800 mAh
5. Tap on OK to save the set charge percent.
Allegro CE Owner’s Manual: K - 44
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
The New Battery Detected screen closes and the charge status is set. Once the battery pack is fully
charged (using the Allegro AC adapter), the gauging is automatically set to 100%. The battery task bar
icon indicator now accurately reflects the battery charge.
New Battery Detected Screen
There are other situations when you turn on your Allegro and the New Battery Detected screen pops up,
directing you to set the values for battery charge percent and battery charge capacity. The following are
reasons for this:
-
Restore function is used
Set Factory Defaults function is used
Power is removed from the Allegro because the battery is fully discharged
Removal and replacement of the battery pack
These values must be set correctly for the battery charge function to work properly, as previously outlined
in this section. If you insert a battery pack and do not know what the status is, we recommend you follow
the previous instructions and set the battery charge at 10%. If you do know what the status is, then set
the correct percentage and tap on OK.
Battery Life
Depending on the application, the batteries can last from five to 30 hours between charges (NiMH) or
replacement (alkaline cells) as shown below:
Battery Pack
NiMH
Alkaline
Capacity
3,800 mA hours
1,600 mA hours
Typical Operating Time
12 to 20 hours
5 to 10 hours
The operating times stated above are based on a typical application including: the data are being entered
manually on the keyboard, no external devices are powered by the Allegro, the backlight is used 10% of
the time, and processing time is 20%. The actual operating time could vary from as little as five hours to
as much as 30 hours, depending on the program and how the system is set up.
As a battery pack ages over time and from usage, it does not operate as long on a charge as it did when
it was new. The capacity could be reduced by as much as 50% at the end of its useful life. Over time, the
capacity setting for an individual battery pack may be adjusted downward to account for age.
Battery packs can be recharged approximately 600 times before they need to be replaced. This is
dependent on the temperatures they have been exposed to, operating conditions, and charging and
discharging practices.
Battery Status Icons
There is a battery indicator in the system tray that shows the amount of power left on the battery. The
indicator gives a percentage of the charge left in the battery, as shown below:
Remaining Battery Charge Status: shows the approximate percent of
charge remaining in the batteries (Note: not an exact reading)
When the Battery Voltage Drops
As the battery charge drops to 10%, the voltage begins to drop off rapidly. The Allegro detects this low
battery condition. When the battery indicator begins to flash on and off this lets you know it is time to
recharge or replace the batteries.
When the battery pack voltage drops sufficiently, the Allegro automatically goes into suspend mode.
Charge or replace the batteries as soon as possible. The battery pack has enough charge left to retain
Allegro CE Owner’s Manual: K - 45
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
the system RAM for five minutes, at which point the Allegro completely powers down to prevent damage
to the batteries. If this happens, the Allegro resets after you charge or replace the batteries. Any data that
were not saved to disk are lost.
Lost Data if Batteries are Removed
If the batteries are removed from the Allegro for longer than five minutes, the Allegro resets to the
Desktop instead of resuming to the screen that was last displayed before the batteries were removed. All
data that was stored in RAM are lost. If this happens, the user must run Start|Programs|Utilities|Restore
System in order to get the Allegro system back to its previous state (i.e., applications such as PocketDOS
properly installed).
Power Management Options
To conserve power, the Allegro has an Auto Suspend feature. When the Allegro is on, it turns itself off if
there is no activity after a specified period of time. This feature is on by default and is set at three
minutes when the Allegro is using battery power or always on when the Allegro is connected to the an
external power supply. The Auto Suspend is controlled through the User Control Panel|Power (or
Start|Control Panel|Power) menu.
Another tip for conserving power is to minimize the use of the backlight. If use of the backlight is
necessary, then adjust settings to minimize its brightness and enable the backlight auto-off setting for
continuous idle time. These settings can be adjusted using User Control Panel|Display – Backlight tab (or
Start|Settings|Control Panel|Display - Backlight tab).
Recharging the NiMH Battery Pack
For applications where the Allegro is used for several hours each day, the NiMH batteries can be charged
daily. The Allegro’s built-in intelligent charging circuit manages the charging of the batteries and prevents
them from being overcharged.
You should always be aware of the status of the main batteries before you go out into the field to collect
data. The batteries may need to be recharged before you go. You need to take into account how much
battery life is left and the amount of time required to charge the pack.
Temperature Ranges for Charging the NiMH Battery Pack
The Allegro’s NiMH batteries are charged most efficiently at temperatures ranging between 10° to 20° C
(50° to 68° F) when the AC power adapter is used. The Allegro batteries must be charged when the
battery temperature is between 0° to 40° C (32° to 104° degrees F) due to the nature of NiMH batteries.
Charging Options
AC Power Adapter for Allegro unit: Using the AC power adapter, the battery pack is recharged without
removing it from the Allegro. Please note that you must use the adapter included with the Allegro or one
that is capable of supplying adequate current (12V at 1 Amp). Otherwise, the battery pack could be
damaged. You can run the Allegro from the adapter while the batteries are being charged. To charge the
battery, complete the following steps:
1) Plug the AC charging adapter into an AC outlet.
2) Insert the connector into the external power input jack located on the top of the Allegro case. It
can take up to five hours to fully charge a battery pack.
3) When the batteries are fully charged, the charging circuit switches into trickle charge mode. You
can leave the Allegro connected to the adapter continuously without overcharging or damaging
the batteries.
Allegro CE Owner’s Manual: K - 46
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Cautions for Allegro AC adapter:
•
The plug on the Allegro AC adapter is removable to accommodate European style plugs.
Be careful to pull adapter straight out from the wall plug to avoid leaving plug portion in
the wall.
USB/Power Dock: Using the USB/Power Dock, you can charge the battery pack while the Allegro sits in
the Power Dock. To charge the battery, complete the following steps:
1) Plug the AC charging adapter into an AC outlet.
2) Insert the connector into the external power input jack located on the back of the Power Dock.
Place the Allegro into the Power Dock to begin charging the battery pack until the amber charging
light on the Power Dock goes out. It can take up to five hours to fully charge a battery pack.
3) When the batteries are fully charged, the charging circuit switches into trickle charge mode. You
can leave the Allegro in the Power Dock continuously without overcharging or damaging the
batteries.
External Battery Charger (by Lenmar): The battery pack is removed from the Allegro. To charge the
battery completely using the external battery charger, use the following steps:
1) Plug-in either the AC 110V or DC Cigarette Lighter power adapter as desired. Connect the other
end of the power adapter cable to the power input socket on the charger unit.
2) Align the arrow on the NiMH battery in the direction of the arrow on the charger unit. Next align
the upside down “G” aligned approximately with the right side of the Sharp adapter on the
charger. Slide the battery onto the charger in the direction of the arrows until it clicks and the Red
LED (CHG) indicator will light up and stay on. This indicates that the contacts on the battery are
correctly aligned with the contacts on the charger. (Note: This charger requires that the Sharp
3.6V adapter is installed properly onto the main charger unit.)
3) Leave until fully charged and the Red LED light turns off and the Green LED (FULL) indicator has
turned on. This can take up to five hours and 15 minutes.
4) NiMH batteries may benefit from an occasional discharge if they sit idle for too long a period of
time. If you wish to condition your battery, push the button in the lower right hand corner of base
unit. The Red LED will go out and the Yellow LED (DIS) will begin to flash while the battery is
discharged to the proper voltage. Once discharged, it will automatically begin to charge your
battery. Repeat this for 2-3 cycles to refresh the battery. If the battery is still not working
properly, it may need to be replaced.
Cautions for external battery charger:
•
•
•
•
•
•
Do not leave the battery on connected to the charger for prolonged periods (several
days). Remove the battery after charge is complete.
Unplug the charger when not in use.
Do not use, place or store the charger where it may come into contact with water or
moisture.
Always replace frayed or damaged wire and broken plugs immediately.
Use this charger only with the included AC adapter.
Avoid prolonged use in an automobile when the engine is not running, as it may drain the
battery in the vehicle.
Vehicle Power Adapter for the Allegro: With this adapter, you can charge battery packs via an automobile
cigarette lighter. To charge the battery, complete the following steps:
1) Plug the adapter into the cigarette lighter.
Allegro CE Owner’s Manual: K - 47
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
2) Insert the connector into the external power input jack located on the top of the Allegro case. It
can take up to five hours to fully charge a pack. You can operate the Allegro with this adapter as
well as charge the batteries.
Important Setting for Using Vehicle Power
It is important to have the Allegro in Vehicle Mode when it is left connected to vehicle power for
periods of an hour or more, either directly or via the vehicle power adapter. Vehicle Mode prevents
excessive charging of the NiMH battery pack.
Using Vehicle Mode is necessary because every time the power is cycled (the key to the vehicle is
turned on) the Allegro begins a new battery charge cycle. The Allegro circuitry detects when a battery
pack is fully charged, however, it takes approximately 20 minutes for this to occur. Repeatedly
attempting to charge a fully charged battery pack causes premature degradation in battery
performance. In Vehicle Mode, charging is inhibited if the gauging circuitry indicates that battery pack
is above 90% charged.
To put the Allegro in Vehicle Mode, complete the following steps (the default is for Vehicle Mode to be
off):
1) Tap on the Start menu and select the Settings|Control Panel options, double-tap on Power
icon. The Power Properties screen appears.
2) Tap on the box next to the Select the In-Vehicle Charge Mode option so a check mark
appears. (Refer to Chapter 4, Windows CE, Control Panel for details).
3) Tap on OK.
4)
Your Allegro is now set up fur use in vehicle power mode.
Spare NiMH Battery Packs
Spare battery packs should be stored in a cool location. Avoid placing battery packs “contact side” down
on a metal surface. Also, do not stack packs so that their contacts touch one another. These practices will
cause the batteries to drain. The shelf-life of a battery pack is about two months. Before using a spare
pack, you should charge it.
Battery Gauging Explained
The Allegro's intelligent battery gauging circuit helps you efficiently maintain the batteries for applications.
The percentage of remaining charge in the batteries is indicated through the battery status system tray
icons. The gauging works for both NiMH rechargeable batteries and alkaline batteries, although the
mechanism is different, as outlined in this section.
Note: Battery gauging is provided as a tool to help you manage the batteries. It does not affect the
performance of the Allegro or the batteries in any way. If the gauging circuitry is not properly
synchronized with a NiMH battery, it may show erroneous readings. Please read this section on battery
gauging so you understand the proper setup, functionality, and limitations of battery gauging.
Battery Gauging for the NiMH Rechargeable Battery
The Allegro employs a circuit that watches how much charge is added to or removed from the
rechargeable battery. To illustrate how this circuit works, imagine the battery as a tank of water. The
battery capacity is like the size of the tank in volume. Watching the charge is like watching how much
volume of water flow into or out of the tank. Gauging the battery is like gauging how full the tank is,
without being able to see into it. You must know the size of the tank and how full it was to start with to
determine the amount of water in the tank. As water flows out of the tank, the percent full can be
calculated by subtracting how much water has flowed out of the tank from the starting point and then
dividing by the capacity of the tank.
Allegro CE Owner’s Manual: K - 48
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
This is exactly what the Allegro does, except it monitors milliamp-hours of electric charge instead of the
volume of water. For the battery gauging to work correctly on the Allegro, the following values must be
known about the NiMH battery pack:
- Charge percent
- Capacity
Setting the battery charge percent and capacity are both described earlier in this chapter in the Setting
Battery Charge section.
The battery gauging is an estimate. It works well in applications where the Allegro is used heavily and
charged every day. When it is not used much and goes several days between charges, the gauging may
not be as accurate in reflecting the true charge of the battery pack. The accumulated error can be as
much as 5% per day. To avoid errors, keep the Allegro attached to the AC charging adapter or in the
USB/Power Dock when you are not going to use it for a few days. This practice prevents the battery pack
from self-discharging. The battery stays fully charged and the battery gauging reflects the correct status
of the battery pack.
Battery Gauging Using Alkaline Batteries
Alkaline batteries have a better slope to the voltage discharge curve than NiMH batteries. Because of
this, the voltage can be read directly to gauge the battery charge percent. The gauging may vary
depending on the grade and brand of the batteries being used. For best results, we recommend that you
use the new types of alkaline batteries such as the Duracell Ultra™ and Energizer Titanium™.
Temperature and loading affect alkaline battery voltage and may cause the gauging to behave differently
in different environmental conditions. When moving from a cold environment to a warm one, the battery
charge status bar indicators may actually move up instead of down. This happens because in cold
temperatures the alkaline batteries actually have less capacity than in warm temperatures and this is
reflected in the voltage output.
Storing the Allegro CE During Inactive Periods
To protect the Allegro and your files during long or short-term storage periods, please take the following
precautions:
-
Close all application programs.
Run the Save System utility. (This has already been done for PNW data recorders.)
The data and programs are secure as long as they have been saved to the non-volatile solid state
storage, even if the batteries become discharged. The Allegro does not depend on the battery to store the
data for extended periods.
Storing the Allegro CE for Less Than Two Months
If you store the Allegro for less than two months, we recommend that you leave the NiMH battery pack in
the Allegro and attach the AC power adapter to keep the batteries charged or leave the Allegro in the
USB/ Power Dock. Once the battery pack is fully charged, the Allegro switches to trickle charge mode.
You can leave the Allegro in trickle charge mode continuously without damaging the batteries. The
battery pack will be fully charged when you are ready to use the Allegro.
Note: Do not leave the Allegro plugged into a wall outlet where the power to that outlet cycles on and off
frequently. The battery can become damaged from overcharging.
Storing the Allegro CE for More Than Two Months
If you store the Allegro for more than two months, perform a Save System to save all data on the
Allegro’s internal data storage, remove the battery pack from the Allegro, and place the Allegro on a shelf.
When you are ready to use the Allegro, insert a battery pack and fully charge it as outlined in the
Allegro CE Owner’s Manual: K - 49
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
beginning of the Batteries section. The Allegro will automatically restore the saved system and reset the
time on the Allegro. You are now ready to begin using the Allegro again.
Short-Term Backup Power Supply
The Allegro has a super capacitor that behaves like a backup battery. When the main batteries are
removed, the capacitor maintains the RAM for up to five minutes, allowing you plenty of time to change
the batteries. The capacitor cannot operate the Allegro. The capacitor is charged by the batteries. It holds
a charge as long as the batteries or external power are supplied. When a battery pack is replaced, the
capacitor charges up to full capacity in about two minutes
If power is not supplied to the Allegro for more than five minutes, the Allegro resets when the battery pack
is replaced or charged. All the programs, data, and applications saved to the disk are safe. Information
that was not saved to the disk is lost. The super capacitor should not need replacement through the life of
the Allegro.
Real-Time Clock
The Allegro DOES NOT have a backup clock. You will need to reset the clock on the Allegro when the
Allegro’s power completely stops for over five minutes. During the startup sequence after loss of power,
you will be prompted for the current date and time.
User Control Panel Options (in Windows CE)
To open the User Control Panel, tap on the icon found on the Allegro desktop. Press
Start\Settings\Control Panel.
A Control Panel screen, similar to the one shown below, will appear. Double-tap on the application you
want to view.
Note: You must press the OK button when settings in a Control Panel applet are changed in order for the
settings to be saved. Once the Control Panel applets are set up the way you want, run the Save System
utility to save all settings (described later in this chapter of the manual).
Date/Time
The Date/Time Properties applet is used to set the current date, time, and time zone. The calendar allows
you to select the correct month, day, and year.
Allegro CE Owner’s Manual: K - 50
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
The Current Time option allows you to set the correct hour and minute during the day. The Time Zone
option allows you to select which time zone you are in.
Note: The “Daylight savings time in effect” option does not affect the Current Time when this option is
selected/deselected and applied. If you are in a time zone that is affected by daylight savings, select the
“Daylight savings time in effect” function and tap on Apply. When daylight saving comes into effect on
your calendar, the time automatically changes. Your Allegro receives a pop-up notification that your clock
has changed.
Display
The Display Properties applet has several tabs controlling different display features. Each tab has
features allowing you to change different appearance options of your Windows CE desktop. The
Background tab gives you options for the desktop background image (the default is None). The
Appearance tab allows you to change the color scheme of the display contents (the default is High
Contrast White). Windows Standard and High Contrast Black are also recommended.
The Backlight tab allows you to select the length of time you want the backlight to remain on while the
Allegro is in an idle state. The Backlight tab also allows you to set the brightness of the backlight.
Allegro CE Owner’s Manual: K - 51
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
The Options tab is used to set the display heater and contrast. The heater options are Auto and Off. Auto
is the default setting, which turns on the heater automatically. Adjust the display contrast by moving the
slide bar left or right.
Note: The display heater cannot be used if you are using alkaline batteries. The Auto option is not
available.
Keyboard
The Keyboard Properties has a Repeat tab used to enable or disable character repeat when you hold
down a key on your Allegro keyboard. If the Enable character repeat is selected, you can set the repeat
delay and repeat rate.
Allegro CE Owner’s Manual: K - 52
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Owner
The Owner Properties applet uses the Identification tab to specify personal information, such as your
name, address, and phone number.
The Notes tab provides a place to add any additional information that is not included in the Identification
tab.
Communication
The Communication Properties applet allows you to change the port and baud rate used for
communicating with your Allegro and PC through ActiveSync. The USB port is the default setting.
Allegro CE Owner’s Manual: K - 53
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
If you are not using a USB Power Dock to connect your Allegro with your PC, tap on the Change button to
access the change connection screen.
Tapping on the down arrow accesses the drop-down list of available connection options. Tap on the Com
type your Allegro is using and tap on OK to save the new setting. NE’s TALLY and PDRcon programs
utilizes COM1 @ 115k baud. If you do not want to change the COM port, tap on X to cancel out of the
Change Connection screen and return to the PC Connection Properties screen.
Allegro CE Owner’s Manual: K - 54
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Power
The Power Properties applet shows information about the power level of the batteries in your Allegro. The
Battery tab shows the status of the main battery.
The Power Off tab allows you to specify how much time will pass before the Allegro goes into suspend
mode. The Allegro can also be suspended while it is running on external power.
Allegro CE Owner’s Manual: K - 55
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Stylus
The Stylus Properties applet uses the Double-Tap tab to set up and test the double-tap sensitivity for
speed and distance between taps.
From the Calibration tab, the touchscreen is recalibrated. If you have trouble selecting an item when you
tap on it, the touchscreen may need to be recalibrated.
The Recalibrate option can be accessed from the Calibration tab’s Recalibrate button, or it will
automatically appear during system boot if the Allegro has been without any batteries for longer than 15
minutes.
Allegro CE Owner’s Manual: K - 56
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
When calibrating the touch screen, hold the stylus down on the plus mark (+) for two seconds. Complete
this procedure for each + mark shown on the touch screen for correct calibration. Press Enter when
prompted.
Volume and Sounds
The Volume & Sounds Properties applet Volume tab, is used to adjust the speaker volume and turn on
and off the sounds associated with different system events.
From the Sounds tab, you can associate a sound with an action. The actions are listed on the left. The
actions that have sounds associated with them, have a speaker icon next to them (like an Asterisk in the
screen shown below).
Allegro CE Owner’s Manual: K - 57
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
To edit, add, or listen to a sound, make a selection from the list on the left. The name of your selection is
shown in the Sound box if a sound is already associated with it. Otherwise, it says None. Select Browse
to find and select the desired sound WAV file that you want associated with the selected action. To listen
to the new sound (or existing sound), press the right arrow button next to the Sound box. Changes you
make can be saved as a new sound Scheme or you can choose an existing sound scheme from the drop
down list.
ActiveSync Connection
ActiveSync is a communications software that allows your desktop/laptop computer to communicate with
the Allegro handheld device.
Installing ActiveSync
To install ActiveSync on your PC, complete the following steps:
1) Open the downloaded copy of ActiveSync or insert your Microsoft ActiveSync CD into your PC’s
CD-ROM drive and select the Install ActiveSync option. Double-click this file to begin install.
2) Click on the Next button and follow the instructions given to you by the ActiveSync Setup
program. When ActiveSync is installed the “Get Connected” screen appears.
3) Click on the Cancel button on the “Get Connected” screen so you can continue to set up the
communication settings. The following dialog appears:
4) Click on the OK button.
5) Restart your computer.
Note: Although it may work without a restart, to avoid problems connecting, restart your desktop PC
before completing the connection process.
There are two procedures for establishing a connection between the Allegro and your PC. The first is the
initial ActiveSync connection (only very first connection after install), and the second is for all connections
after the first one. If you have just downloaded and installed ActiveSync then complete the steps in the
following section, Establishing a First Time ActiveSync Connection. If you already have ActiveSync
installed proceed to Establishing Additional ActiveSync Connections section found later in this chapter.
Allegro CE Owner’s Manual: K - 58
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Establishing a First Time ActiveSync Connection
There are two procedures for establishing a connection between the Allegro and your PC. The first is the
initial ActiveSync connection and the second is for all connections after the first one. If you have just
downloaded and installed ActiveSync then complete the following steps. If you already have ActiveSync
installed proceed to Establishing Additional ActiveSync Connections section found later in this chapter.
The Allegro CE has four communication ports available for establishing an ActiveSync connection
between the Allegro and desktop PC. The communication ports available are:
1.
2.
3.
4.
COM 1
COM 2
Infrared
USB
COM 1 or 2 Serial Connection
When establishing a COM 1 or 2 connection between the Allegro and your desktop PC for the first time,
complete the following steps; all additional connections can be made by following the steps in the
ActiveSync Connection Process section found later in this chapter.
1) Using COM 1 or 2, attach one end of the serial communication cable to the COM port on your
desktop PC. Plug the other end of the communication cable into COM 1 or 2 on the Allegro. You
must use the communication cable included with the Allegro CE, part number 12446.
2) Turn on the Allegro. Tap the Start button and select Settings|Control Panel|Communications
Properties. Tap the PC Connection tab. At the bottom of the dialog box under Connect using:,
the COM port the Allegro is set on for the connection process is shown. If the communication
port you are using is not listed in the bottom dialog box under Connect using, tap the Change
button. Select the correct port and baud rate from the drop-down list. Tap on the OK button.
3) Double-click on the ActiveSync icon on the desktop PC. The following screen is shown:
Allegro CE Owner’s Manual: K - 59
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
4) Click on the Next button on the Get Connected: Checking COM Ports screen. The following
screen is shown:
5) If the cable is connected to COM 1 on the PC, the Progress box of the Checking COM Ports
screen says Looking for a Mobile device…Checking on COM Port 1, double-tap on the PC Link
icon on your Allegro desktop.
After tapping the PC Link icon on the Allegro desktop, a screen that says Connecting to Host is shown.
After a connection is made, the following screen briefly shows on the Allegro:
If you are unsuccessful in your connection go to the An Unsuccessful Connection section found later in
this chapter.
If using COM 2 on the Allegro, wait for the Progress box of the Checking COM Ports screen indicating
Looking for a Mobile device… Checking on COM Port 1 to advance to Checking on COM Port 2. Now
double-tap on the PC Link icon on your Allegro desktop:
Once connected, this screen is automatically minimized and placed in the status box on the Taskbar.
If the Allegro becomes disconnected from the desktop PC by choice or inadvertently, this symbol
disappears, letting you know the Allegro is not connected to the computer. A screen on the desktop PC
that says Connecting is shown. The New Partnership: Set Up a New Partnership screen appears.
Proceed to the Setting Up a Partnership heading of this section.
Allegro CE Owner’s Manual: K - 60
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
USB/Power Dock Connection
If you already have ActiveSync installed and for all additional connections go to the ActiveSync
Connection Process section found later in this chapter. When establishing a USB connection between
the Allegro and the desktop PC for the first time, complete the following steps:
1) Plug in the USB cable into the desktop PC and then into USB/Power Dock.
2) Double-click on the ActiveSync icon on the desktop PC.
3) Place the Allegro into the USB/Power Dock. The Allegro automatically turns on and the Getting
Connected screen disappears.
USB is the default port and should already be selected. To double-check the setting, open the User
Control Panel|PC Connection as described in the previous section. If the communication port you are
using is not listed in the bottom dialog box under Connect using, tap the Change button. If the USB
default is not selected, select the USB port from the dropdown list. Tap the OK button.
To connect remove the Allegro from the USB/Power Dock then place it back into the USB/Power Dock.
This will automatically start the connection process.
A screen on the desktop PC that says Connecting is shown. The New Partnership: Set Up a New
Partnership appears. Select “No”, and then use PNW Plot Utilities or Windows Explorer to start
transferring plot files.
Note: If you are having problems with the Allegro connecting to the desktop PC while using the USB
connection, perform a reset on the Allegro and repeat the USB connection process.
An Unsuccessful Connection
If the connection was not successful, the following screen appears on the PC:
From here, click on the Next button on the Your device was not detected screen and the Getting
Connected screen appears again. Perform a reset on the Allegro (by holding the On/Off button for 8
seconds), and repeat the connection instructions for the COM port you are using until a successful
connection is made.
Allegro CE Owner’s Manual: K - 61
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
Establishing Additional ActiveSync Connections
If you already have ActiveSync installed on your desktop PC, complete the following steps for connecting
the Allegro to the desktop PC. These instructions are also designed for all additional connections to
between the Allegro and desktop PC using ActiveSync. You do not need to set up the communication
settings each time, as described in Establishing a First Time Connection Using ActiveSync.
1) Turn on the Allegro and the desktop PC.
2) Connect the communication cable to the ports (or align IrDA ports) as set up on each computer
during the ActiveSync installation process.
Note: This can be adjusted as needed. Just remember to change the connection settings on
both the laptop and the Allegro. (See Troubleshooting section for more information.)
3) Press the PC Link icon on the Allegro’s desktop. If you are using the USB/Power Dock, place
your Allegro into the Power Dock to initiate an ActiveSync connection. The following screen is
briefly shown on the Allegro display:
If you set up a partnership between the Allegro and desktop PC, the connection is made
automatically. When the connection is complete the following screen is shown:
4) Press the Explore button to view the contents of the Allegro from the desktop PC.
5) If you did not initially set up a partnership you may be shown the Set Up a Partnership screen.
Select Yes to set up a partnership now or No to connect as a guest.
ActiveSync Troubleshooting
If you have any problems establishing communication between the Allegro and the desktop PC, here are
some suggested troubleshooting steps.
1) Verify/adjust the communication settings on the desktop computer under the ActiveSync
File|Connection Settings....
2) Verify/adjust the communication settings on the Allegro device under User Control Panel|PC
Connection.
Allegro CE Owner’s Manual: K - 62
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
3) Verify the physical connection is okay. This varies depending on the connection type:
- Serial: communication cable is firmly connected to the correct ports
- IrDA: path between infrared ports is not blocked
- USB: Allegro is seated firmly in the USB docking station
4) to see if a warm boot (reset) of the Allegro solves the problem
5) to see if a reboot of the desktop/laptop computer (esp. since install of ActiveSync)
Refer to the installation instructions for ideas on settings to review.
Connecting as a Guest (recommended)
ActiveSync also allows you to connect as a guest and interact between both computers without setting up
a partnership. To connect as a guest complete the following steps:
1) Select the No option on the Set Up a Partnership screen, and click on the Next button.
ActiveSync goes through the connection process. When connected, the following screen
appears:
2) Click on the Explore option on the Microsoft ActiveSync screen or open Windows Explorer:
Allegro CE Owner’s Manual: K - 63
National Core Field Guide, Version 3.0
October, 2005
Northeast Edition
3) Begin viewing the contents of the Allegro. Note: In Windows Explorer, look under My
Computer|Mobile Device
Allegro CE Owner’s Manual: K - 64
Download