Bid No. B15-02 Building 1100 Roofing Overlay Addendum No. 1 This Addendum No. 1 sets forth modifications to portions of the bid and contract documents for the above-referenced work described as: B15-02 Building 1100 Roofing Overlay 1) Rake Flashing Detail – Upper Roof Plane, Elevations North and South At the existing rake lines (upper roof-approximately 160 linear feet total) the existing composite roofing is to be cut back approximately one inch to plane flush with the face of the rake fascia. Custom 3.5” x 2” flashing is to be installed in advance of installation of the new shingles. All new flashing is to be primed and painted. Please reference Section 1400 “Flashing and Sheet Metal” of the project specifications for flashing specifications. Please reference Section 1500 “Painting” of the project specifications for painting specification. 2) Please clarify the area receiving the built-up bituminous roofing. Please clarify if the new built-up bituminous roofing is going over existing shingles. No areas of the roof will receive bituminous roofing. B15-02 Bldg 1100 Roofing Overlay, Addendum No. 1 1