KANSAS STATE UNIVERSITY EQUINE PERFORMANCE TESTING CENTER BUILDING NUMBER: 36700-00235

advertisement
303 South Topeka
Wichita, KS 67202
T: 316.262.2691
PEC1.COM
1800 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
A-012593
A SPECIALTY PRACTICE OF GH2 ARCHITECTS, LLC
320 South Boston, Suite 1600
Tulsa, OK 74103
T: 918.587.6158 GH2.COM
KANSAS STATE UNIVERSITY
EQUINE PERFORMANCE TESTING CENTER
EXTERIOR PERSPECTIVE
EXTERIOR PERSPECTIVE
EVALUTATION AREAS
CONFERENCE ROOM
EXTERIOR PERSPECTIVE
CONFERENCE ROOM
SMALL CONSULTATION ROOM
INTERIM REVIEW
ONLY
DOCUMENT INCOMPLETE.
NOT INTENDED FOR PERMIT,
BIDDING OR CONSTRUCTION
COVER SHEET
CODE COMPLIANCE PLAN
SYMBOL LEGEND
BUILDING SECTION
AND REFERENCE
LOCATION MAP
X
X
AXX
AXX
PAT
ROBERTS
HALL
CIVIL
SITE GRADING PLAN
GH2 Architects, LLC
320 South Boston, Suite 1600
Tulsa, Oklahoma 74103
Tel 918.587.6158, Fax 918.587.0357, www.gh2.com
ENGINEER
CIVIL, MEP, STRUCTURAL
AS101
A101
A110
A201
A202
A301
A302
A303
A304
A401
A402
A403
ARCHITECTURAL SITE PLAN
OVERALL FLOOR PLAN
ROOF PLAN
EXTERIOR ELEVATIONS
EXTERIOR ELEVATIONS
BUILDING SECTIONS
BUILDING SECTIONS
BUILDING SECTIONS
BUILDING SECTIONS
ENLARGED FLOOR PLAN
ENLARGED FLOOR PLAN
ENLARGED FLOOR PLAN
MECHANICAL
Professional Engineering Consultants, P.A.
303 South Topeka
Wichita, Kansas 67202
Tel 316.262.2691, www.pec1.com
M001
MECHANICAL EQUIPMENT LAYOUT
ROOM NAME
ROOM NUMBER
X
PROJECT LOCATION
ROOM
xxx
DENISON AVE
ARCHITECTURAL
ENLARGED
FLOOR PLAN
XXX
C001
ELEVATION OR
HEIGHT SYMBOL
A
GRID BUBBLE
1
MOSIER
HALL
TROTTER
HALL
COLES
HALL
ELECTRICAL EQUIPMENT LAYOUT
COVER SHEET
A-012593
ELECTRICAL
E001
1810 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
DATE: FEBRUARY 2, 2015
DRAWN BY: KBA
G001
G002
WASH AREA / STALLS
EQUINE PERFORMANCE TESTING CENTER
SHEET INDEX
STALLS / AISLE / EXAM AREA
KANSAS STATE UNIVERSITY
VETERINARY HEALTH CENTER
ARCHITECT
STALL BARN AISLE - ENTRY VIEW
SERUM PLANT ROAD
EVALUTATION AREAS
Department of Administration
Office of Facilities &
Procurement Management
Design, Construction & Compliance
800 SW Jackson, Suite 700
Topeka, Kansas 66612-1216
Phone 785-296-8899
ARCHITECT: MICHAEL HALL
LICENSE #: A5618
JARDINE DR
G001
SCHEMATIC
DESIGN
© 2014 COPYRIGHT GH2 ARCHITECTS, LLC
37'
MECHANICAL
278 SF
REF.
75.75 x .15"=11.36"
40"
Storage / B
4
WARMING
KITCHEN
232 SF
Kitchen / B
2
26'
SMALL
CONSULTATION
ROOM
220 SF
320 South Boston, Suite 1600
Tulsa, OK 74103
T: 918.587.6158 GH2.COM
STORAGE
1144 SF
61'
23'
Business / B
3
A SPECIALTY PRACTICE OF GH2 ARCHITECTS, LLC
Mech / B
1
SOFT
SURFACE
EVALUATION
AREA - 70' x
140'
9773 SF
HARD
SURFACE
LUNGING
AREA
3073 SF
CONFERENCE/
CONSULTATION
ROOM
1023 SF
CIRCULATION
793 SF
GTH RT
LEN E APA
L
C
O
GN TAN
' DIA /3 DIS
0
4
2
1
IN.
SM
T
I
EX
Agricultural / B
10.25
Assembly without Fixed Seats,
Unconcentrated (Tables & Chairs) / B
69
MEN'S
RESTROOM
202 SF
75.75 x .15"=11.36"
40"
303 South Topeka
Wichita, KS 67202
T: 316.262.2691
PEC1.COM
WOMEN'S
RESTROOM
203 SF
Agricultural / B
33
58'
ENTRY
VESTIBULE
151 SF
JANITOR'S
CLOSET
29 SF
STORAGE
162 SF
TELECOM
CLOSET
30 SF
Storage / B
.75
CIRCULATION
843 SF
114'
HARD
SURFACE
TROT-UP 15' x 140'
1969 SF
184'
Agricultural / B
7
164'
54.25 x .15"=8.13"
240"
75.75 x .15"=11.36"
40"
OCCUPANT LOAD LEGEND
5.25 x .15"=.78"
36"
EQUIPMENT
ROOM
128 SF
Storage / B
.5
Agricultural / B
1.25
FARRIER
AREA
190 SF
OPEN EXAM
AREA
247 SF
Agricultural / B
1
Agricultural / B
1
ASSEMBLY WITHOUT FIXED
SEATS, UNCONCENTRATED
(Tables & Chairs) (15 NSF)
1,023 SQ. FT. - 1,023/15 = 68.2
69 OCCUPANTS
AGRICULTURAL BUILDING
(300 GSF) 16,381 SQ. FT 16,333/300 = 54.4
56 OCCUPANTS
BUILDING TOTAL NET SF: 23,542
KITCHENS, COMMERCIAL (200 GSF)
232 SQ. FT. - 232/200 = 1.16
2 OCCUPANTS
TOTAL OCCUPANTS: 138
65'
49'
CIRCULATION
AISLE
1117 SF
Storage / B
.75
: ANTICIPATED LONGEST EXIT ACCESS TRAVEL DISTANCE
CIRCULATION
AISLE
362 SF
80'
COVERED
FARRIER
PARKING
451 SF
: REQUIRED EXIT - EXTERIOR
: REQUIRED EXIT OR EXIT ACCESS - INTERIOR
OCCUPANTS / REQUIRED WIDTH
STALL
144 SF
Agricultural / B
.5
STALL
144 SF
Agricultural / B
.5
STALL
144 SF
Agricultural / B
.5
STALL
144 SF
Agricultural / B
.5
WASH
144 SF
STORAGE
156 SF
PROVIDED WIDTH
Agricultural / B
.5
Storage / B
.75
ROOM TYPE / OCCUPANCY TYPE
: ACCUMULATED EXIT WIDTH AT REQUIRED EXIT
MAXIMUM ALLOWABLE OCCUPANTS :
DOCUMENT INCOMPLETE.
NOT INTENDED FOR PERMIT,
BIDDING OR CONSTRUCTION
ARCHITECT: MICHAEL HALL
LICENSE #: A5618
LEGEND
H RT
GT
A
LEN CE AP
L
O
N
N
AG STA
' DI 1/3 DI
5
0
1 IN.
SM
T
I
EX
INTERIM REVIEW
ONLY
ROOM DESIGNATION
FE
A


CODE INFORMATION
BUILDING CODE REVIEW
EGRESS REQUIREMENTS
PLUMBING FIXTURE REQUIREMENTS PER IBC TABLE 2902.1
2006
2006
2006
2006
2006
2006
2006
2007
2007
2007
2008
2008
2007
2005
1. SQUARE FEET:
● NEW (29,600) GROSS SQUARE FEET
(INCLUDING COVERED LOADING/UN-LOADING, COVERED FARRIER PARKING AND
COVERED CONNECTOR)
1. MEANS OF EGRESS (TABLE 1015.1):
● MAXIMUM OCCUPANT LOAD FOR ONE EXIT=49
LAVATORIES
INTERNATIONAL BUILDING CODE
INTERNATIONAL BUILDING FIRE CODE
INTERNATIONAL RESIDENTIAL CODE
INTERNATIONAL MECHANICAL CODE
INTERNATIONAL PLUMBING CODE
INTERNATIONAL FUEL GAS CODE
INTERNATIONAL ENERGY CONSERVATION CODE
NFPA - PORTABLE FIRE EXTINGUISHERS
NFPA - INSTALLATION OF SPRINKLER SYSTEMS
NFPA - INSTALLATION OF STANDPIPE AND HOSE SYSTEMS
NFPA - TESTING FIRE SPRINKLER SYSTEMS
NATIONAL ELECTRIC CODE
NATIONAL FIRE ALARM CODE
EMERGENCY AND STANDBY POWER SYSTEMS
KANSAS FIRE PREVENTION CODE
2010 AMERICANS WITH DISABILITIES ACT (AADAG) WITH UPDATES
KANSAS STATE BOILDER CODE
2. USE AND OCCUPANCY CLASSIFICATION:
● BUSINESS GROUP B (SECTION 304)
3. BUILDING TYPE, ALLOWABLE HEIGHT, AND BUILDING AREA:
● NEW BUILDING TYPE: IIB
● FIRE-RESISTANCE RATING FOR NEW BUILDING ELEMENTS IIB: (TABLE 601)
STRUCTURAL FRAME 0
EXTERIOR BEARING WALLS 0 HR
INTERIOR BEARING WALLS 0 HR
EXTERIOR NONBEARING WALLS AND PARTITIONS 0 AND 1HR (SEE TABLE 602)
INTERIOR NONBEARING WALLS AND PARTITIONS 0HR
FLOOR CONSTRUCTION 0HR
ROOF CONSTRUCTION 0HR
● ALLOWABLE TYPE IIB BUILDING AREA: UNLIMITED BUILDING AREA (SECTION 507.3)
● ALLOWABLE BUILDING HEIGHT: 5 STORIES (TABLE 503 & SECTION 504.2)
4. BUILDING TO BE FULLY SPRINKLED
2. NUMBER OF EXITS (TABLE 1019.1):
● 2 EXITS: 1 - 500 OCCUPANTS
3. MAXIMUM TRAVEL DISTANCE-EXIT ACCESS TRAVEL DISTANCE (TABLE 1016.1):
● 300 FEET WITH SPRINKLER SYSTEM
4. SWING OF EGRESS DOOR (1008.1.2):
● SWING IN DIRECTION OF EGRESS TRAVEL WITH OCCUPANT LOADS OF 50+
5. CORRIDOR FIRE RESISTANCE RATING (TABLE 1017.1):
● OCCUPANY GROUP B, GREATER THAN 30 OCCUPANTS:
0HR RATING WITH SPRINKLER SYSTEM
6. CORRIDORS
● MAXIMUM DEAD END (SECTION 1017.3 - EXCEPTION 2):
WITH SPRINKLER SYSTEM SHALL NOT EXCEED 50'
6. CORRIDORS / EGRESS WIDTH
● MINIMUM WIDTH (TABLE 1005.1) WITH SPRINKLER SYSTEM:
CORRIDOR / EGRESS WIDTH IS 0.15" PER OCCUPANT
MALE: 1 PER 40 OCCUPANTS FOR FIRST
80 & 1 PER 80 FOR REMAINDER
EXCEEDING 80:
69 MALE OCCUPANTS
69 OCC /40 = 1.7 | 2
2 LAVATORIES REQUIRED
2 LAVATORIES PROVIDED
FEMALE: 1 PER 40 OCCUPANTS FOR FIRST
80 & 1 PER 80 FOR REMAINDER
EXCEEDING 80:
69 MALE OCCUPANTS
69 OCC /40 = 1.7 | 2
2 LAVATORIES REQUIRED
2 LAVATORIES PROVIDED
WATER CLOSETS / URINALS
MALE: 1 PER 25 OCCUPANTS FOR FIRST 50 &
1 PER 50 FOR REMAINDER
EXCEEDING 50:
69 MALE OCCUPANTS
69 OCC /25 = 2.7 | 3
3 WATERCLOSETS/URINALS REQUIRED
3 WATERCLOSETS/URINALS PROVIDED
DRINKING FOUNTAINS
1 FOUNTAIN PER 100 OCCUPANTS
138 OCC /100 = 1.38 | 2
2 FOUNTAINS REQUIRED
2 FOUNTAINS PROVIDED
FEMALE: 1 PER 25 OCCUPANTS FOR FIRST
50 & 1 PER 50 FOR REMAINDER
EXCEEDING 50:
69 MALE OCCUPANTS
69 OCC /25 = 2.7 | 3
3 WATERCLOSETS REQUIRED
3 WATERCLOSETS PROVIDED
KANSAS STATE UNIVERSITY
VETERINARY HEALTH CENTER
: FIRE EXTINGUISHER
2.5 x .15"=.375"
36"
1810 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
DATE: FEBRUARY 2, 2015
DRAWN BY: KBA
IMAGING
ROOM
361 SF
FUTURE
RESIDENT
FARRIER
TOOLS/
SUPPLIES
209 SF
ACCESSORY STORAGE
AREAS, MECHANICAL,
EQUIPMENT ROOM (300 GSF)
2,063 SQ. FT - 2,063/300 = 6.87
8 OCCUPANTS
EQUINE PERFORMANCE TESTING CENTER
44'
BUSINESS (100 GSF)
220 SQ. FT. - 220/100 = 2.2
3 OCCUPANTS
Department of Administration
Office of Facilities &
Procurement Management
Design, Construction & Compliance
800 SW Jackson, Suite 700
Topeka, Kansas 66612-1216
Phone 785-296-8899
COVERED
CONNECTOR
728 SF
CODE COMPLIANCE
PLAN
A-012593
G002
SCHEMATIC
DESIGN
© 2014 COPYRIGHT GH2 ARCHITECTS, LLC
1810 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
DATE: FEBRUARY 2, 2015
EQUINE PERFORMANCE TESTING CENTER
Department of Administration
Office of Facilities &
Procurement Management
Design, Construction & Compliance
800 SW Jackson, Suite 700
Topeka, Kansas 66612-1216
Phone 785-296-8899
osier
Hall
KANSAS STATE UNIVERSITY
VETERINARY HEALTH CENTER
Serum Plant Rd.
INTERIM REVIEW
ONLY
DOCUMENT INCOMPLETE.
NOT INTENDED FOR PERMIT,
BIDDING OR CONSTRUCTION
ARCHITECT: MICHAEL HALL
LICENSE #: A5618
SITE GRADING PLAN
A-012593
C001
SCHEMATIC
DESIGN
© 2014 COPYRIGHT GH2 ARCHITECTS, LLC
303 South Topeka
Wichita, KS 67202
T: 316.262.2691
PEC1.COM
A SPECIALTY PRACTICE OF GH2 ARCHITECTS, LLC
320 South Boston, Suite 1600
Tulsa, OK 74103
T: 918.587.6158 GH2.COM
SW
10
66
FL
A SPECIALTY PRACTICE OF GH2 ARCHITECTS, LLC
320 South Boston, Suite 1600
Tulsa, OK 74103
T: 918.587.6158 GH2.COM
303 South Topeka
Wichita, KS 67202
T: 316.262.2691
PEC1.COM
FL
69
10
67
10
TURN-OUT 60'x42'
107
1
SW
FL
FL FL
1070
TURN-OUT 60'x42'
72
10
GROUND WATER CUTTOFF TRENCH
1072
EXISTING
HAY BARN
1071
107
3
FL
1069
NEW HORSE PATH
WH
TURN-OUT 60'x42'
73
10
1067
TURN-OUT 60'x42'
1070
87
10
1088
1091
10
78
1065
1072
10
92
89
10
10
80
1086
1085
1083
1090
10
91
1077
5
107
1070
1065
1067
4
107
72
10
EXISTING
TREES
NEW EQUINE PERFORMANCE
TESTING CENTER
EXISTING
GRAVEL
INTERIM REVIEW
ONLY
DOCUMENT INCOMPLETE.
NOT INTENDED FOR PERMIT,
BIDDING OR CONSTRUCTION
108
7
STAFF PARKING
ELECTRICAL
LINE
1072
EXISTING VETERINARY
MEDICINE - MOSIER HALL
NEW EQUINE PERFORMANCE
TESTING CENTER SUPPORT BARN
10
86
72
10
COMM. LINE
10
85
10
82
107
1
1075
NEW ASPHALT PAVING
80
10
EQUINE LOADING/ UNLOADING
3
107
TRUCK/TRAILER PARKING
FL
10
84
WATER LINE
1072
107
0
1079
EXISTING FENCE
77
10
1068
KANSAS STATE UNIVERSITY
VETERINARY HEALTH CENTER
1063
1065
1067
1075
1067
107
1
65
10
1063
0
107
ELECTRICAL LINE
1072
FL
1071
67
10
68
10
1065
1062
1066
1067
1069
FL
WH
1810 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
DATE: FEBRUARY 2, 2015
DRAWN BY: KBA
10 - PULL THROUGH TRUCK/TRAILER PARKING SPACES 12'x45' EACH
1072
NEW
CONCRETE
PATIO
ARCHITECT: MICHAEL HALL
LICENSE #: A5618
EQUINE PERFORMANCE TESTING CENTER
1073
8
108
1074
EXISTING
CONCRETE
SERUM PLANT ROAD
FL
Department of Administration
Office of Facilities &
Procurement Management
Design, Construction & Compliance
800 SW Jackson, Suite 700
Topeka, Kansas 66612-1216
Phone 785-296-8899
FOOD ANIMAL LOADING/
UN-LOADING
T
WH
WH
ARCHITECTURAL
SITE PLAN
A

A-012593






AS101
SCHEMATIC
DESIGN
© 2014 COPYRIGHT GH2 ARCHITECTS, LLC
3
4
5
6
7
8
9
10
11
12
257'-5"
14' - 2 1/2"
15' - 9 1/2"
25'-3"
25'-3"
25'-3"
A
C
A
B
B
A302
A302
A301
A302
A301
25'-3"
25'-3"
A202
25'-3"
25'-3"
25'-3"
25'-3"
C
A301
A
A SPECIALTY PRACTICE OF GH2 ARCHITECTS, LLC
2
320 South Boston, Suite 1600
Tulsa, OK 74103
T: 918.587.6158 GH2.COM
1
A
MECHANICAL
278 SF
STORAGE
1144 SF
22'-10"
REF.
WARMING
KITCHEN
232 SF
GATE
PROVIDE HYDRANT
A
B
HARD SURFACE
LUNGING AREA
3073 SF
CONFERENCE/
CONSULTATION
ROOM
1023 SF
CIRCULATION
793 SF
C
MEN'S
RESTROOM
202 SF
HIGH VOLUME
LOW SPEED "BIG
ASS" FANS ABOVE
B
A303
JANITOR'S
CLOSET
STORAGE
29 SF
162 SF
TELECOM
CLOSET
30 SF
STAINED
CONCRETE
FLOORING
VENDING ALCOVE
CIRCULATION
843 SF
E
ASPHALT FLOORING
GATE- TYP.
PROVIDE HYDRANT
HARD SURFACE
TROT-UP - 15' x
140'
1969 SF
5' HIGH LOW WALL
GATE- TYP.
PROVIDE HYDRANT
CONCRETE RIBBON CURB
WITH CHAMFERED EDGE
5' HIGH LOW WALL
DISH CHANNEL
DRAIN- TYP.
INTERIM REVIEW
ONLY
PROVIDE HYDRANT
DOCUMENT INCOMPLETE.
NOT INTENDED FOR PERMIT,
BIDDING OR CONSTRUCTION
5' HIGH LOW WALL
ARCHITECT: MICHAEL HALL
LICENSE #: A5618
23'-6"
F
A
A401
COVERED
CONNECTOR
728 SF
A
A403
Department of Administration
Office of Facilities &
Procurement Management
Design, Construction & Compliance
800 SW Jackson, Suite 700
Topeka, Kansas 66612-1216
Phone 785-296-8899
CONCRETE
SIDEWALK
A
A402
CONCRETE BORDER
ASPHALT FLOORING
G
15'-8"
CONCRETE FLOORING
CONCRETE FLOORING
WITH RUBBER MATS
IMAGING ROOM
361 SF
RAIL
PROVIDE HOSE BIB WITH
RETRACTABLE HOSE
BOLLARD-TYP.
H
TRENCH
DRAIN
PROVIDE HYDRANT
DRAIN
TRENCH DRAIN
OPEN EXAM
AREA
247 SF
EQUIPMENT
ROOM
128 SF
FARRIER AREA
190 SF
RAIL
ASPHALT
FLOORING
FUTURE
RESIDENT
FARRIER TOOLS/
SUPPLIES
209 SF
A
A304
19'-4"
CROSS TIE POST
PROVIDE HOSE BIB WITH
RETRACTABLE HOSE
COVERED
LOADING/
UN-LOADING
870 SF
DRAIN
B
CIRCULATION
AISLE
1117 SF
CONCRETE
THRESHOLD- TYP.
A304
CIRCULATION
AISLE
362 SF
COVERED
FARRIER
PARKING
451 SF
ASPHALT FLOORING
I
4'-8"
CONCRETE FLOORING WITH RUBBER MATS IN STALLS & WASH AREA
J
PROVIDE HYDRANT
11'-2"
ASPHALT
FLOORING
STALL
144 SF
STALL
144 SF
STALL
144 SF
STALL
144 SF
DRAIN- TYP.
WASH
144 SF
TRENCH
DRAIN
ASPHALT PAVING
STORAGE
156 SF
RECESSED HOT/COLD
VALVE WITH
RETRACTABLE HOSE
ASPHALT
PAVING
K
1810 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
DATE: FEBRUARY 2, 2015
DRAWN BY: KBA
LIGHTED
BOLLARDTYP.
EQUINE PERFORMANCE TESTING CENTER
23'-8"
HIGH VOLUME
LOW SPEED "BIG
ASS" FANS ABOVE
VIEWING
SCREEN
D
16'-6"
GATE- TYP.
ASPHALT FLOORING
STAINED
CONCRETE
FLOORING
ENTRY
VESTIBULE
151 SF
CONCRETE
SIDEWALK
162'-3"
HIGH VOLUME
LOW SPEED "BIG
ASS" FANS ABOVE
RAIL
RECESSED
WALK-OFF
MAT
A303
SOFT SURFACE
EVALUATION
AREA - 70' x 140'
9773 SF
KANSAS STATE UNIVERSITY
VETERINARY HEALTH CENTER
25'-0"
WOMEN'S
RESTROOM
203 SF
A201
RETAINING WALLHEIGHT TO BE
CONFIRMED
5'-4" HIGH WALL
PASS-THRU
WINDOW
VIEWING
SCREEN
SMALL
CONSULTATION
ROOM
220 SF
B
GATE
303 South Topeka
Wichita, KS 67202
T: 316.262.2691
PEC1.COM
RETAINING WALLHEIGHT TO BE
CONFIRMED
ASPHALT FLOORING
A
A201
OVERALL
FLOOR PLAN
A
A-012593








A101
SCHEMATIC
DESIGN
© 2014 COPYRIGHT GH2 ARCHITECTS, LLC
A
B
303 South Topeka
Wichita, KS 67202
T: 316.262.2691
PEC1.COM

6
A
C
A
B
B
A302
A302
A301
A302
A301







7
A202
I
J
K
A
A201
8
9
10
11
C
A
A301
A
F
B
A202
G
A
A304
H
B
A304
A SPECIALTY PRACTICE OF GH2 ARCHITECTS, LLC
5
320 South Boston, Suite 1600
Tulsa, OK 74103
T: 918.587.6158 GH2.COM
4
1810 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
DATE: FEBRUARY 2, 2015
DRAWN BY: KBA
3
EQUINE PERFORMANCE TESTING CENTER
2
Department of Administration
Office of Facilities &
Procurement Management
Design, Construction & Compliance
800 SW Jackson, Suite 700
Topeka, Kansas 66612-1216
Phone 785-296-8899
A201
KANSAS STATE UNIVERSITY
VETERINARY HEALTH CENTER
1
12
A
A303
B
C
A303
B
D
E
INTERIM REVIEW
ONLY
DOCUMENT INCOMPLETE.
NOT INTENDED FOR PERMIT,
BIDDING OR CONSTRUCTION
ARCHITECT: MICHAEL HALL
LICENSE #: A5618
ROOF PLAN
A-012593
A110
SCHEMATIC
DESIGN
© 2014 COPYRIGHT GH2 ARCHITECTS, LLC
A SPECIALTY PRACTICE OF GH2 ARCHITECTS, LLC
320 South Boston, Suite 1600
Tulsa, OK 74103
T: 918.587.6158 GH2.COM
303 South Topeka
Wichita, KS 67202
T: 316.262.2691
PEC1.COM
A
A
B
B
C
A303
A303
A
D
E
F
G
A304
B
H
A304
I
J
K
CONTINUOUS RIDGE
VENT
CONTINUOUS RIDGE
VENT
METAL ROOFING
EAVE HEIGHT
114' - 0"
FINISH FLOOR
100' - 0"
SPLIT FACE
MASONRY BLOCK
METAL SIDING
B
BOLLARD- TYP.







INTERIM REVIEW
ONLY
DOCUMENT INCOMPLETE.
NOT INTENDED FOR PERMIT,
BIDDING OR CONSTRUCTION
C
3
4
A
A302
B
A301
A302
5
B
6
C
A301
7
8
9
10
11
12
A301
METAL ROOFING
CONTINUOUS RIDGE
VENT
EAVE HEIGHT
114' - 0"
SPLIT FACE
MASONRY BLOCK
A
HIGH WINDOWS







METAL SIDING
GATES TO TROT-UP /
ARENA
TOP OF RETAINING
WALL BEYOND
5'-0" HIGH LOW WALL
FINISH FLOOR
100' - 0"
1810 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
DATE: FEBRUARY 2, 2015
DRAWN BY: KBA
A302
2
EQUINE PERFORMANCE TESTING CENTER
A
KANSAS STATE UNIVERSITY
VETERINARY HEALTH CENTER
1
Department of Administration
Office of Facilities &
Procurement Management
Design, Construction & Compliance
800 SW Jackson, Suite 700
Topeka, Kansas 66612-1216
Phone 785-296-8899
ARCHITECT: MICHAEL HALL
LICENSE #: A5618
EXTERIOR
ELEVATIONS
A-012593
A201
SCHEMATIC
DESIGN
© 2014 COPYRIGHT GH2 ARCHITECTS, LLC
A SPECIALTY PRACTICE OF GH2 ARCHITECTS, LLC
320 South Boston, Suite 1600
Tulsa, OK 74103
T: 918.587.6158 GH2.COM
303 South Topeka
Wichita, KS 67202
T: 316.262.2691
PEC1.COM
B
K
J
I
A
A304
H
B
A304
G
F
E
D
A
C
A303
B
A303
A
CONTINUOUS RIDGE
VENT
CONTINUOUS RIDGE
VENT
EAVE HEIGHT
114' - 0"
FINISH FLOOR
100' - 0"
BOLLARDTYP.
B
SPLIT FACE
MASONRY BLOCK
METAL SIDING
5'-0" HIGH LOW WALL
GATES TO ARENA







INTERIM REVIEW
ONLY
DOCUMENT INCOMPLETE.
NOT INTENDED FOR PERMIT,
BIDDING OR CONSTRUCTION
9
8
7
C
A301
CONTINUOUS RIDGE
VENT
6
B
A301
5
B
A302
4
3
A
A301
C
A302
2
A
1
A302
METAL ROOFING
EAVE HEIGHT
114' - 0"
METAL SIDING
TOP OF RETAINING WALL SHOWN AT 8'-0" HIGH
A







TOP OF RETAINING WALL
SHOWN AT 6'-0" HIGH
SPLIT FACE
MASONRY BLOCK
FINISH FLOOR
100' - 0"
1810 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
DATE: FEBRUARY 2, 2015
DRAWN BY: KBA
10
EQUINE PERFORMANCE TESTING CENTER
11
KANSAS STATE UNIVERSITY
VETERINARY HEALTH CENTER
12
Department of Administration
Office of Facilities &
Procurement Management
Design, Construction & Compliance
800 SW Jackson, Suite 700
Topeka, Kansas 66612-1216
Phone 785-296-8899
ARCHITECT: MICHAEL HALL
LICENSE #: A5618
EXTERIOR
ELEVATIONS
A-012593
A202
SCHEMATIC
DESIGN
© 2014 COPYRIGHT GH2 ARCHITECTS, LLC
B
C
A303
A
D
A303
E
F
G
A304
B
H
I
A304
J
K
A SPECIALTY PRACTICE OF GH2 ARCHITECTS, LLC
A
B
320 South Boston, Suite 1600
Tulsa, OK 74103
T: 918.587.6158 GH2.COM
A
SOFT SURFACE
EVALUATION
AREA - 70' x 140'
9773 SF
C
FINISH FLOOR
100' - 0"
FUTURE
RESIDENT
FARRIER TOOLS/
SUPPLIES
209 SF
HARD SURFACE
TROT-UP - 15' x
140'
1969 SF
303 South Topeka
Wichita, KS 67202
T: 316.262.2691
PEC1.COM
EAVE HEIGHT
114' - 0"
COVERED
FARRIER
PARKING
451 SF







A
A
B
B
C
A303
A
D
A303
E
F
G
A304
B
H
I
A304
J
K
EAVE HEIGHT
114' - 0"
INTERIM REVIEW
ONLY
FINISH FLOOR
100' - 0"
COVERED
CONNECTOR
728 SF
CIRCULATION
843 SF
CIRCULATION
AISLE
1117 SF
WASH
144 SF
ARCHITECT: MICHAEL HALL
LICENSE #: A5618






A
A
B
B
C
A303
A303
A
D
E
F
G
B
A304
H
A304
I
J
K
EAVE HEIGHT
114' - 0"
FINISH FLOOR
100' - 0"
MECHANICAL
278 SF
A
WARMING
KITCHEN
232 SF
CONFERENCE/
CONSULTATION
ROOM
1023 SF

STORAGE
162 SF
IMAGING ROOM
361 SF
CIRCULATION
AISLE
1117 SF
1810 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
DATE: FEBRUARY 2, 2015
DRAWN BY: KBA

EQUINE PERFORMANCE TESTING CENTER
Department of Administration
Office of Facilities &
Procurement Management
Design, Construction & Compliance
800 SW Jackson, Suite 700
Topeka, Kansas 66612-1216
Phone 785-296-8899
B
HARD SURFACE
LUNGING AREA
3073 SF
KANSAS STATE UNIVERSITY
VETERINARY HEALTH CENTER
STORAGE
1144 SF
DOCUMENT INCOMPLETE.
NOT INTENDED FOR PERMIT,
BIDDING OR CONSTRUCTION
STALL
144 SF
BUILDING
SECTIONS
A-012593






A301
SCHEMATIC
DESIGN
© 2014 COPYRIGHT GH2 ARCHITECTS, LLC
B
C
A303
A303
A
D
E
F
G
A304
B
H
A304
I
J
K
A SPECIALTY PRACTICE OF GH2 ARCHITECTS, LLC
A
B
320 South Boston, Suite 1600
Tulsa, OK 74103
T: 918.587.6158 GH2.COM
A
303 South Topeka
Wichita, KS 67202
T: 316.262.2691
PEC1.COM
EAVE HEIGHT
114' - 0"
FINISH FLOOR
100' - 0"
SMALL
CONSULTATION
ROOM
220 SF
C
WOMEN'S
RESTROOM
203 SF
MEN'S
RESTROOM
202 SF
ENTRY
VESTIBULE
151 SF






B
K
J
I
A304

A
H
B
G
A304
F
E
D
A303
A
C
B
A303
A
EAVE HEIGHT
114' - 0"
INTERIM REVIEW
ONLY
FINISH FLOOR
100' - 0"
CIRCULATION
843 SF
STORAGE
1144 SF
HARD SURFACE
LUNGING AREA
3073 SF
ARCHITECT: MICHAEL HALL
LICENSE #: A5618






A
A
B
B
C
A303
A303
A
D
E
F
G
A304
B
H
A304
I
J
K
EAVE HEIGHT
114' - 0"
FINISH FLOOR
100' - 0"
WOMEN'S
RESTROOM
203 SF
MEN'S
RESTROOM
202 SF
1810 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
DATE: FEBRUARY 2, 2015
DRAWN BY: KBA

EQUINE PERFORMANCE TESTING CENTER
Department of Administration
Office of Facilities &
Procurement Management
Design, Construction & Compliance
800 SW Jackson, Suite 700
Topeka, Kansas 66612-1216
Phone 785-296-8899
B
OPEN EXAM
AREA
247 SF
KANSAS STATE UNIVERSITY
VETERINARY HEALTH CENTER
CIRCULATION
AISLE
1117 SF
DOCUMENT INCOMPLETE.
NOT INTENDED FOR PERMIT,
BIDDING OR CONSTRUCTION
BUILDING
SECTIONS
A

A-012593






A302
SCHEMATIC
DESIGN
© 2014 COPYRIGHT GH2 ARCHITECTS, LLC
A SPECIALTY PRACTICE OF GH2 ARCHITECTS, LLC
320 South Boston, Suite 1600
Tulsa, OK 74103
T: 918.587.6158 GH2.COM
303 South Topeka
Wichita, KS 67202
T: 316.262.2691
PEC1.COM
12
11
10
9
8
7
6
C
A301
5
B
A301
B
4
A302
3
A
A301
2
C
A302
1
A
A302
EAVE HEIGHT
114' - 0"
SOFT SURFACE
EVALUATION
AREA - 70' x 140'
9773 SF
ENTRY
VESTIBULE
151 SF
INTERIM REVIEW
ONLY
DOCUMENT INCOMPLETE.
NOT INTENDED FOR PERMIT,
BIDDING OR CONSTRUCTION






ARCHITECT: MICHAEL HALL
LICENSE #: A5618

Department of Administration
Office of Facilities &
Procurement Management
Design, Construction & Compliance
800 SW Jackson, Suite 700
Topeka, Kansas 66612-1216
Phone 785-296-8899
B
CONFERENCE/
CONSULTATION
CIRCULATION
ROOM
793 SF
1023 SF
HARD SURFACE
LUNGING AREA
3073 SF
FINISH FLOOR
100' - 0"
C
A302
3
A
A302
4
5
B
A301
A302
B
A301
6
C
7
8
9
10
11
12
A301
EAVE HEIGHT
114' - 0"
FINISH FLOOR
100' - 0"
WOMEN'S
RESTROOM
203 SF
A
CONFERENCE/
CONSULTATION
ROOM
1023 SF
HARD SURFACE
LUNGING AREA
3073 SF
SOFT SURFACE
EVALUATION
AREA - 70' x 140'
9773 SF
1810 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
DATE: FEBRUARY 2, 2015
DRAWN BY: KBA
2
EQUINE PERFORMANCE TESTING CENTER
A
KANSAS STATE UNIVERSITY
VETERINARY HEALTH CENTER
1
BUILDING
SECTIONS







A-012593
A303
SCHEMATIC
DESIGN
© 2014 COPYRIGHT GH2 ARCHITECTS, LLC
A SPECIALTY PRACTICE OF GH2 ARCHITECTS, LLC
320 South Boston, Suite 1600
Tulsa, OK 74103
T: 918.587.6158 GH2.COM
303 South Topeka
Wichita, KS 67202
T: 316.262.2691
PEC1.COM
12
11
10
9
8
7
6
C
B
A301
5
4
B
A301
A302
3
A
A301
C
A302
2
A
1
A302
EAVE HEIGHT
114' - 0"
COVERED
FARRIER
PARKING
451 SF
B
FINISH FLOOR
100' - 0"
CIRCULATION
AISLE
362 SF
CIRCULATION
AISLE
1117 SF

INTERIM REVIEW
ONLY





DOCUMENT INCOMPLETE.
NOT INTENDED FOR PERMIT,
BIDDING OR CONSTRUCTION

Department of Administration
Office of Facilities &
Procurement Management
Design, Construction & Compliance
800 SW Jackson, Suite 700
Topeka, Kansas 66612-1216
Phone 785-296-8899
ARCHITECT: MICHAEL HALL
LICENSE #: A5618
A302
C
3
A
A302
4
5
B
A301
A302
B
A301
6
C
7
8
9
10
11
12
A301
EAVE HEIGHT
114' - 0"
FINISH FLOOR
100' - 0"
IMAGING ROOM
361 SF
A
EQUIPMENT
ROOM
128 SF
OPEN EXAM
AREA
247 SF
CIRCULATION
AISLE
1117 SF
FARRIER AREA CIRCULATION
FUTURE
AISLE
RESIDENT
190 SF
FARRIER
TOOLS/
362 SF
SUPPLIES
209 SF
1810 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
DATE: FEBRUARY 2, 2015
DRAWN BY: KBA
2
EQUINE PERFORMANCE TESTING CENTER
A
KANSAS STATE UNIVERSITY
VETERINARY HEALTH CENTER
1
BUILDING
SECTIONS







A-012593
A304
SCHEMATIC
DESIGN
© 2014 COPYRIGHT GH2 ARCHITECTS, LLC
2
3
4
5
6
7
C
A
B
B
C
A302
A302
A301
A302
A301
A301
320 South Boston, Suite 1600
Tulsa, OK 74103
T: 918.587.6158 GH2.COM
A
A
MECHANICAL
278 SF
ASPHALT FLOORING
WARMING
KITCHEN
232 SF
GATE
303 South Topeka
Wichita, KS 67202
T: 316.262.2691
PEC1.COM
STORAGE
1144 SF
REF.
GATE
5'-4" HIGH WALL
PROVIDE HYDRANT
PASS-THRU
WINDOW
VIEWING
SCREEN
B
A SPECIALTY PRACTICE OF GH2 ARCHITECTS, LLC
1
SMALL
CONSULTATION
ROOM
220 SF
WOMEN'S
RESTROOM
203 SF
A
A303
SOFT SURFACE
EVALUATION
AREA - 70' x 140'
9773 SF
HARD SURFACE
LUNGING AREA
3073 SF
CIRCULATION
793 SF
CONFERENCE/
CONSULTATION
ROOM
1023 SF
C
INTERIM REVIEW
ONLY
MEN'S
RESTROOM
202 SF
DOCUMENT INCOMPLETE.
NOT INTENDED FOR PERMIT,
BIDDING OR CONSTRUCTION
HIGH VOLUME
LOW SPEED "BIG
ASS" FANS ABOVE
B
ENTRY
VESTIBULE
151 SF
A303
FLOORING
VIEWING
SCREEN
JANITOR'S
CLOSET
29 SF
D
LIGHTED
BOLLARDTYP.
TELECOM
CLOSET
30 SF
HARD SURFACE
TROT-UP - 15' x
140'
1969 SF
CIRCULATION
843 SF
STAINED
CONCRETE
FLOORING
PROVIDE HYDRANT
GATE- TYP.
VENDING ALCOVE
E
5' HIGH LOW WALL
COVERED
CONNECTOR
728 SF
5' HIGH LOW WALL
KANSAS STATE UNIVERSITY
VETERINARY HEALTH CENTER
STORAGE
162 SF
1810 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
DATE: FEBRUARY 2, 2015
DRAWN BY: KBA
ASPHALT FLOORING
STAINED
CONCRETE
EQUINE PERFORMANCE TESTING CENTER
RAIL
RECESSED
WALK-OFF
MAT
Department of Administration
Office of Facilities &
Procurement Management
Design, Construction & Compliance
800 SW Jackson, Suite 700
Topeka, Kansas 66612-1216
Phone 785-296-8899
ARCHITECT: MICHAEL HALL
LICENSE #: A5618
ENLARGED
FLOOR PLAN
F
A-012593
A401
A

SCHEMATIC
DESIGN







© 2014 COPYRIGHT GH2 ARCHITECTS, LLC
7
8
9
10
11
12
C
A
303 South Topeka
Wichita, KS 67202
T: 316.262.2691
PEC1.COM
RETAINING WALLHEIGHT TO BE
CONFIRMED
A SPECIALTY PRACTICE OF GH2 ARCHITECTS, LLC
320 South Boston, Suite 1600
Tulsa, OK 74103
T: 918.587.6158 GH2.COM
A301
STORAGE
1144 SF
RETAINING WALLHEIGHT TO BE
CONFIRMED
B
A
A303
HARD SURFACE
LUNGING AREA
3073 SF
SOFT SURFACE
EVALUATION
AREA - 70' x 140'
9773 SF
GATE- TYP.
C
INTERIM REVIEW
ONLY
DOCUMENT INCOMPLETE.
NOT INTENDED FOR PERMIT,
BIDDING OR CONSTRUCTION
A303
CONCRETE RIBBON CURB
WITH CHAMFERED EDGE
5' HIGH LOW WALL
ASPHALT FLOORING
GATE- TYP.
HARD SURFACE
TROT-UP - 15' x
140'
1969 SF
PROVIDE HYDRANT
E
DISH CHANNEL
DRAIN- TYP.
PROVIDE HYDRANT
KANSAS STATE UNIVERSITY
VETERINARY HEALTH CENTER
D
1810 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
DATE: FEBRUARY 2, 2015
DRAWN BY: KBA
B
EQUINE PERFORMANCE TESTING CENTER
HIGH VOLUME
LOW SPEED "BIG
ASS" FANS ABOVE
Department of Administration
Office of Facilities &
Procurement Management
Design, Construction & Compliance
800 SW Jackson, Suite 700
Topeka, Kansas 66612-1216
Phone 785-296-8899
HIGH VOLUME
LOW SPEED "BIG
ASS" FANS ABOVE
ARCHITECT: MICHAEL HALL
LICENSE #: A5618
ENLARGED
FLOOR PLAN
A-012593
A
A402








SCHEMATIC
DESIGN
© 2014 COPYRIGHT GH2 ARCHITECTS, LLC
1
2
C
A302
A
3
A301
B
4
B
5
A302
C
6
A301
A301
320 South Boston, Suite 1600
Tulsa, OK 74103
T: 918.587.6158 GH2.COM
A302
7
CIRCULATION
843 SF
CIRCULATION
793 SF
E
A SPECIALTY PRACTICE OF GH2 ARCHITECTS, LLC
A
303 South Topeka
Wichita, KS 67202
T: 316.262.2691
PEC1.COM
5' HIGH LOW WALL
F
CONCRETE
SIDEWALK
COVERED
CONNECTOR
728 SF
CONCRETE BORDER
ASPHALT FLOORING
G
CONCRETE FLOORING
TRENCH DRAIN
PROVIDE
HYDRANT
TRENCH DRAIN
DRAIN
ASPHALT
FLOORING
CONCRETE FLOORING
WITH RUBBER MATS
A
A304
IMAGING ROOM
361 SF
BOLLARD-TYP.
OPEN EXAM
AREA
247 SF
EQUIPMENT
ROOM
128 SF
FARRIER AREA
190 SF
FUTURE
RESIDENT
FARRIER TOOLS/
SUPPLIES
209 SF
H
RAIL
RAIL
PROVIDE HYDRANT
INTERIM REVIEW
ONLY
CROSS TIE
POST- TYP.
DOCUMENT INCOMPLETE.
NOT INTENDED FOR PERMIT,
BIDDING OR CONSTRUCTION
CONCRETE
THRESHOLD- TYP.
COVERED
LOADING/
UN-LOADING
870 SF
CIRCULATION
AISLE
362 SF
CIRCULATION
AISLE
1117 SF
ASPHALT FLOORING
COVERED
FARRIER
PARKING
451 SF
I
J
STALL
144 SF
CONCRETE
FLOORING WITH
RUBBER MATS
STALL
144 SF
CONCRETE
FLOORING WITH
RUBBER MATS
STALL
144 SF
CONCRETE
FLOORING WITH
RUBBER MATS
STALL
144 SF
CONCRETE
FLOORING WITH
RUBBER MATS
WASH
144 SF
TRENCH DRAIN
DRAIN- TYP.
ASPHALT
FLOORING
STORAGE
156 SF
ASPHALT
PAVING
RECESSED HOT/COLD
VALVE WITH
RETRACTABLE HOSE
KANSAS STATE UNIVERSITY
VETERINARY HEALTH CENTER
CONCRETE
FLOORING WITH
RUBBER MATS
ARCHITECT: MICHAEL HALL
LICENSE #: A5618
ASPHALT PAVING
K
A
A201
1810 DENISON AVENUE; MANHATTAN, KANSAS 66502
BUILDING NUMBER: 36700-00235
DATE: FEBRUARY 2, 2015
DRAWN BY: KBA
B
A304
EQUINE PERFORMANCE TESTING CENTER
DRAIN
Department of Administration
Office of Facilities &
Procurement Management
Design, Construction & Compliance
800 SW Jackson, Suite 700
Topeka, Kansas 66612-1216
Phone 785-296-8899
RECESSED HOT/COLD
VALVE WITH
RETRACTABLE HOSE
ENLARGED
FLOOR PLAN
A

A-012593







A403
SCHEMATIC
DESIGN
© 2014 COPYRIGHT GH2 ARCHITECTS, LLC
 
  
    
MECHANI
CAL
EQUI
PMENT
M001
 
  
    
ELECTRI
CAL
EQUI
PMENT
E001
Download