NEW Series SF Output to 60A, 600 Vac (Flatpac) Solid-State Relays FEATURES/BENEFITS • Random and zero-cross models available for all applications • Low zero-cross turn-on voltage • Input protection and control LED standard • Connectors for power wiring and heat sinks available • Designed in conformity with EN60947-4-3 (IEC947-4-3) Part No. Load Voltage Load Current Control Voltage Switch Type SF24D25 12-280 Vac 25A 3-32 Vdc Zero Cross SF24R50HE 12-275 Vac 50A 3-32 Vdc Random SF60D50HE 24-600 Vac 50A 3.5-32 Vdc Zero Cross NOTES TYPICAL APPLICATION line protection - 1) Line Voltage (nominal): 24 = 240 Vac; 60 = 600 Vac 1/L1 4/A2- 2) Switch Type: R= Random turn-on; D = Zero-cross turn-on Control 3) Feature: HE = High Efficiency Thyristors ZC Imax=64A @ Tcase=85°C 2/T1 Imax=44A @ Tcase=100°C + ELECTRICAL SPECIFICATIONS (+25°C ambient temperature unless otherwise specified) INPUT (CONTROL) SPECIFICATIONS Min Max 3/A1+ LED 1/L1 and 2/T2 can be changed LOAD SSR must be mounted on a heatsink Units Typical application: 5 kW resistor (AC-51 load) on 230 VAC Input Current Range All Relays 10 13 Must Turn-Off Voltage 2.0 mA Vdc Reverse Voltage Protection (D) 32 V Clamping Voltage (D) 36 V Input Immunity (EN61000-4-4) 2 kV Input Immunity (EN61000-4-5) 2 kV Figure 2a — SF24D25 CONTROL CHARACTERISTICS line protection )NPUT#URRENTM! - 1/L 1 4/A2- Control + ZC 3/A1+ LED 2/T1 * 1/L1 et 2/T2 peuvent être inversées/ 1/L1 bebe changed 1/L1and and2/T2 2/T1can can swapped. * le relais doit être monté sur dissipateur thermique / SSR must be mounted a heatsink SSR must be mounted ononheatsink LOAD #ONTROL6OLTAGE6 Figure 1 © 2011 TELEDYNE RELAYS Figure 2a — SF60D50HE & SF24R50HE (800) 284-7007 • www.teledynerelays.com SF Page 1 SF\032011\Q1 NEW Series SF Output to 60A, 600 Vac (Flatpac) Solid-State Relays ELECTRICAL SPECIFICATIONS (+25°C ambient temperature unless otherwise specified) Operating Frequency All Relays 0.1 800 Hz 25 output current 600 A2s 50 output current 1680 A2s 25 output current 0.17 °C/W 50 output current 0.55 °C/W OUTPUT (LOAD) SPECIFICATIONS Min Max Units SF24D25 12 280 Vac SF24R50HE 12 275 Vac SF60D50HE 24 600 Vac Operating Range Peak Voltage (VDR Clamping) SF24D25 & SF24R50HE 600 Vpeak SF60D50HE 1200 Vpeak I2t for fuse matching (<10ms) Junction-Case Thermal Resistance Conducted Immunity Level IEC/EN61000-4-4 (bursts) Load Currrent Range (Resistive) SF48 25 output current .005 25 Arms 50 output current .005 60 Arms 2kV criterion A IEC/EN61000-4-5 (surge) SF48 2kV criterion A with external VDR Maximum Surge Current Rating (Non-Repetitive) 25 output current 350 A 50 output current 580 A On-State Voltage Drop 0.85 V MECHANICAL SPECIFICATION 1.77 (45) max Output Power Dissipation (Max) 0.9 x 0.85 x I + 0.016 x I2 W 50 output current 0.9 x 0.85 x I + 0.0075 x I2 W 0.20(5.2) 25 output current Zero-Cross Window (Typical) SFXXD ±17.5 1.10 (28) Vac M5 mA SFXXD 10 ms SFXXR 0.05 ms 10 ms 0.28 (7) Turn-On Time (60 Hz) Turn-Off Time (60 Hz) SFXXD 1.87 (47.6) 1 1.70 (43.2) All Relays 2.30 (58.5) max Off-State Leakage Current Ø 0.185 (4.7) 0.64 (16.3) Off-State dv/dt 500 V/μs Maximum di/dt (Non-Repetitive) 50 A/μs SF Page 2 1.00 (25.4) M4 Dimensions in inches (mm) Weight: 2.29 (65 g) SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Figure 3 © 2011 TELEDYNE RELAYS SF\032011\Q1 NEW Series SF Output to 60A, 600 Vac (Flatpac) Solid-State Relays Input-Output Isolation GENERAL SPECIFICATIONS (+25°C ambient temperature unless otherwise specified) ENVIRONMENTAL SPECIFICATIONS 4000 Vrms 25A output current 4000 Vrms 50A output current 4000 Vrms Insulation Resistance @500Vdc 1000 MΩ Output-Case Isolation Min Max Units 25A output current –55 +100 °C 50A output current –40 +100 °C Operating Temperature Rated Impulse Voltage Storage Temperature 25A output current –55 +125 °C Vibration (10–55 Hz according to CE168) 50A output current –40 +125 °C Shock (according to CD168) Housing Material Ambient Humidity 40 to 85 V 1.5 mm 30/50 g PA6 UL94VO Baseplate % 4000 Aluminum, nickel-plated SURGE CURRENT 600 250 150 Apeak Apeak 200 No-Repetitive 100 Repetitive 0 0.01 0.1 1 Non-Repetitive 1 2 200 1 2 50 400 Repetitive 0 0.01 10 0.1 1 t (s) 10 t(s) Figure 4a — 25A output current Figure 4b — 50A output current THERMAL CURVES Power Dissipation (W) 1.5C/W 1.1C/W 25 25 Full on State 4C/W 20 20 6C/W 15 15 10 0.95C/W 80 30 Power Dissipation (W) 2.1C/W 30 70 Full on State 50% on State 0 5 10 15 RMS load current (A) 20 5 25 80 70 1.5C/W 60 60 50 50 2.1C/W 40 40 30 30 20 0 0.55C/W 10 12C/W 5 0.75C/W 1.1C/W 0 0 10 20 30 40 50 60 70 80 90 100 Ambient temperature (°C) Figure 5a — 25A output power 20 6K /W 50% on State 10 10 0 0 5 10 15 20 25 30 35 40 45 50 55 60 RMS load current (A) 0 0 10 20 30 40 50 60 70 80 90 100 Ambient temperature (C) Figure 5b — 50A output power 12°C/W corresponds to a relay without heat sink 6°C/W corresponds to a relay mounted on a DIN-rail adaptor (Teledyne P/N DL12) © 2011 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com SF Page 3 SF\032011\Q1 NEW Series SF Output to 60A, 600 Vac (Flatpac) Solid-State Relays 2–2.5°C/W Teledyne P/N - FW151 1.1°C/W Teledyne P/N - FW108 Thermal Pad Teledyne P/N –12 DIN Rail Adapter Teledyne P/N - DL12 Applications Teledyne's new Flatpac is designed to be used in applications where height is limited. Below is an example of 6 solid state relays in-line where controls are directly connected to a PCB. Teledyne's new Flatpac can be used where power terminals must be in a 90° angle. SF Page 4 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2011 TELEDYNE RELAYS SF\032011\Q1