For use with a grounded, 3-wire power supply source in... Lighted lamp is HOT − do not touch lens or...

advertisement
For Con-Tech Lighting Linear Accent Lighting: UH and UX Series
For use with a grounded, 3-wire power supply source in dry locations only
Lighted lamp is HOT − do not touch lens or enclosure.
Mount fixtures a minimum of 12" from any object located under fixtures.
To reduce the possibility of injury, mount the fixture on a surface that is
structurally sound.
Power Switch
Lens
Power
Cord
Plug
INSTALLATION PROCEDURES
PLUG-IN ASSEMBLY
Note: Cord/Plug and interconnect cable is not intended for use through, or
concealed behind, walls, floors or ceilings.
1. Disconnect power before installing or servicing fixture.
2. With lens facing you, slide lens releases back and lift lens. Locate and
identify lamp socekts.
3. Using the fixture as a template, trace the outline of the mounting holes
onto mounting surface.
4. Drill pilot holes (Figure 2). Insert mounting screws in each hole and
tighten. Loosen each screw one (1) turn for fixture mounting.
5. Lift fixture into place over the mounting screws and slide fixture to one
side so screw heads are in the keyholes. Tighten mounting screws.
6. Insert lamps into sockets (UH SERIES: 25W T4 Halogen, 120V Lamp
Max.; UX SERIES: 20W T3 Xelogen, 12V Lamp Max.). Close lens and
slide releases forward until it snaps and locks into the housing.
7. Remove plug cover. Insert “IN” plug of power cord into the “IN” plug on
side of fixture. Plug other end of power cord into desired grounded outlet.
Lens Release
Mounting Screws
Mounting Holes
Drill Here
HARDWIRE
CAUTION: RISK OF SHOCK; discard cord if fixtures are directly hardwired.
1. Use hardwire box installation instructionss to mount the box.
2. Follow steps 1-6 of Plug-In Assembly.
3. Remove plug cover. Insert 12" plug-and-play cable (included) from the
fixture plug labeled “OUT” and into the hardwire box. (Figure 3)
Hardwire Box
Labeled
“OUT”
DIRECT WIRE - Installation by licensed electrician only
CAUTION: RISK OF SHOCK; discard cord if fixtures are directly hardwired.
1. Remove knock-out.
2. Secure conduit connector (ordered separately) through knockout and
tighten with hex nut and lock washer.
3. Remove screws from back inside of fixture to expose wires (Figure 4).
Hands-free hanger allows for cover to hang without removal.
4. Connect black wire to black wire to “in” connector/switch wire. Connect
white wire to white wire to transformer/plug-and-play connector.
Connect green to ground. (Figure 5)
5. Replace cover and screw into place.
6. Follow steps 1-6 of Plug-In Assembly.
UH fixtures have a maximum run of 550W (22 x 25W lamps).
UX fixtures have a maximum run of 560W (28 x 20W lamps).
1. Remove plug covers. Attach the 12" plug-and-play cable (provided) from
fixture plug to fixture plug, matching the “IN” and “OUT” labels. (Figure 6)
IMPORTANT SAFETY INSTRUCTIONS:
• Read all the instructions before installation. Save instructions for later use.
• Turn off power at fuse or circuit breaker box before installation or before doing
any maintenance work.
• Product must be grounded to avoid potential electric shock and any other
potential hazards.
• Product must be mounted in locations and at heights and in a manner consistent
with its intended use, and in compliance with National Electrical Code and local
codes. Use of accessory equipment is not recommended.
• Installing contrary to instructions may cause unsafe conditions.
• Do not block light from the trim aperture, in whole or in part, as this may cause
unsafe conditions.
• Warning: Risk of fire. Most dwellings built before 1985 have supply wire rated
at 60°C. Consult a qualified electrician before installation.
• To avoid hazards to children, account for all parts and properly dispose of all
packing materials.
• Call the Technical Support department at Con-Tech Lighting with any installation
questions: 847.559.5500.
1-847-559-5500
www.con-techlighting.com
“IN” CONNECTOR
INTERCONNECTING FIXTURES
Remove for
Direct Wiring
Connect
Green
+
Green
Connect
White
White
Black
TRANS
Connect
Black
SWITCH
All specifications subject to change without notice.
This document can be recycled.
UHUX INST
Download