For ConTech Lighting Non-IC Recessed CFL Housings: RL113, RL118, RL126, RL132, RL213, RL218 and RL226
Housing can NOT be installed in direct contact with insulation. Do not install insulation within 3" of fixture sides or wiring compartment, nor above fixture in such a manner to entrap heat. (Figure 1)
Install hanger bars to fixture, ensure end tab is facing outward. (Figure 2)
JOIST-TYPE CELINGS:
Extend bar hangers to fit between joists and position fixture temporarily by hammering nail on bars into the joists. Hangers should be level with bottom of joists (Figure 3). Locate center of fixture opening in the ceiling sheetrock and cut a 4-3/8" hole for a 4" housing, a 5-3/4" hole for a 5" housing or a
6-3/8" hole for a 6" housing.
SUSPENDED (T-Bar) CEILINGS:
Locate proposed fixture center in ceiling tile and cut a 4-3/8" hole for a 4" housing, a 5-3/4" hole for a 5" housing or a 6-3/8" hole for a 6" housing.
Place ceiling tile in T-Bar grid. Place fixture into position and snap bar hanger foot with integral T-bar clips onto T-bars (Figure 4). Secure hanger bars to T-bars and properly support the fixture from the building structure.
Note: Optional T-Bar Clips and screws may be used as local code authority or site conditions require. To secure fixture position in ceiling, squeeze tabs into hanger bars.
ELECTRICAL CONNECTION:
Remove J-box cover by pushing up on spring clip. Attach conduit with connector to J-box and secure. Connect supply wires to fixture wires and insulate with proper size wire nuts (not provided). Connect black to black
(hot), white to white (neutral), and green to green (ground). After splicing is completed, insert wires carefully into junction box. Replace cover.
BALLAST REPLACEMENT:
If the ballast is not working properly, replace with the same ballast type.
Make sure that power to the fixture is off. Remove lamp. Remove three screws in the housing, remove housing then pull off the junction box cover, installed ballasts and lampholders. Remove ballast from the cover by unscrewing the two screws. Install new ballast, wire to supply wires in the junction box. Replace housing and trim.
INSTALLING TRIMS (FIgure 6)
TORSION SPRINGS: Pull out the slotted spring pryouts. Squeeze the arms together and insert them into the slotted tabs on the inside of the housing. Push upward fully so springs will hold trim in place.
PRESSURE SPRINGS: Bend the slotted tabs upward and insert the trim into the housing. Push upward fully and pressure springs will hold trim in place.
Use only those trims, lamps and maximum wattages proper for this fixture, as indicated on the label within the housing. Do not exceed maximum wattage lamp shown for each trim.
IMPORTANT SAFETY INSTRUCTIONS:
• Read all the instructions before installation. Save instructions for later use.
• Turn off power at fuse or circuit breaker box before installation or before doing any maintenance work.
• Product must be grounded to avoid potential electric shock and any other potential hazards.
• Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in compliance with National Electrical Code and local codes. Use of accessory equipment is not recommended.
• Installing contrary to instructions may cause unsafe conditions.
• Do not block light from the trim aperture, in whole or in part, as this may cause unsafe conditions.
• Warning: Risk of fire. Most dwellings built before 1985 have supply wire rated at
60°C. Consult a qualified electrician before installation.
• To avoid hazards to children, account for all parts and properly dispose of all packing materials.
• Call the Technical Support department at ConTech Lighting with any installation questions: 847.559.5500.
All specifications subject to change without notice.
1.847.559.5500
www.contechlighting.com
T-Bar
JOIST: 2" x 8"
3"
CEILING MATERIAL
Bar Hanger
Nail In Tabs
Optional T-Bar Clip
Note: Tighten screw to secure hanger bar to T-Bar
Ground Wire
This document can be recycled.
Joist
Bar Hanger
INSULATION
3"
White to White
Black to Black
RL113213 INST