IMPORTANT SAFETY INSTRUCTIONS:

advertisement
For ConTech Lighting New Construction/Remodel LED Recessed Multiple Series: RDA6L
IMPORTANT SAFETY INSTRUCTIONS:
• Read all the instructions before installation. Save instructions for later use.
• Turn off power at fuse or circuit breaker box before installation or before doing any maintenance work.
• Product must be grounded to avoid potential electric shock and any other potential hazards. Work on a sturdy, nonconductive ladder.
• Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in compliance with National
Electrical Code and local codes. Use of accessory equipment is not recommended. For indoor use only.
• Installing contrary to instructions may cause unsafe conditions.
• Do not block light from the trim aperture, in whole or in part, as this may cause unsafe conditions. Do not install closer than 6" from any
curtain or similar combustible material.
• Warning: Risk of fire. Most dwellings built before 1985 have supply wire rated at 60°C. Consult a qualified electrician before installation.
• To avoid hazards to children, account for all parts and properly dispose of all packing materials.
• Call the Technical Support department at Con-Tech Lighting with any installation questions: 847.559.5500.
INSTALLATION PROCEDURES: NEW CONSTRUCTION UNITS
J-Box
Flexible Conduit
Housing
Trim Frame
Head Tilt Locking Screw
Hex Head
Screws (4)
Mounting Stud
Flat Hanger Bar
Narrow Slots
C-Channel
Hanger Bar Slots
Continued on page 2
1-847-559-5500
www.contechlighting.com
WIRING DIAGRAM 2
GREEN
GREEN
GROUND
GROUND
JUNCTION BOX
• Trim-less option: housing mounting frame and trimless frame each
contain eight (8) matching fastening points for secure retention in
ceiling. Using #6 drywall screws (supplied by others) fasten the
trimless frame to the drywall and housing mounting frame. Once
secured, joint compound can be applied.
Key Hole
Slots
WIRING DIAGRAM 1
TRIM INSTALLATION
• Trimmed option: Squeeze torsion springs on trim and insert them into
brackets located inside of housing. Push trim upward until it seats
firmly against the ceiling.
Mounting
Frame
RL-KIT #3
WHITE
NEUTRAL
BLACK
LINE
JUNCTION BOX
1. Carefully remove packing inserts and slim inner carton containing the
trim frame.
2. Locate the Hex Key (tightens hex head screws that secure housing to
mounting frame, and head tilt locking screw (Fig. 1).
3. Assemble RL-KIT #3:
• Select “L” bracket with the longer base plate. Attach to long end of
mounting frame with J-Box by fitting keyhole slots in bracket over
the setscrews in mounting frame. Adjust to desired length, tighten
screws. Repeat with remaining bracket on opposite end of mounting frame.
• Mount the wing-style brackets to the “L” brackets with the open end
facing out (Fig. 2). Pass mounting stud through bracket slot,
secure with wing nut and washer provided.
• Narrow slots in the bracket accept flat hanger bars (ConTech
HB-24), C-shaped openings accept C-Channel hanger bars (ConTech
HBC-24). C-shaped openings may also be used for 1/2" conduit.
• Vertical slots in brackets allow a 3" overall height adjustment.
Desired housing position is for the mounting frame lip to be even
with the finished ceiling, firmly tighten the wing nut.
4. Use Hex Key to make final height adjustments of the housing within
the mounting frame (3/4” maximum height adjustment). DO NOT
PLACE ANY INSULATION MATERIAL WITHIN THREE INCHES OF
THE HOUSING.
5. The RDA6L housing is pre-wired. Power must only be brought to the
junction box on the housing. Maximum of 8 No. 12 AWG through
branch circuit conductor suitable for 75°C permitted in box.
WARNING: Power source must conform to requirements of the fixture
(see labels on fixture), all NEC and local electrical codes.
Before starting wire connections, disconnect power at
circuit breaker or fuse, turning power off at switch leg is not
sufficient to prevent electrical shock. Make junction box
connections per appropriate wiring diagram, based upon
dimming option being installed (Fig. 3) Close junction box
cover after wiring (ensure that all wires are within box
before closing).
PURPLE
0-10V CONTROL
GRAY
WHITE
NEUTRAL
BLACK
LINE
120V and 277V
Electrical/Dimming (TRIAC & ELV)
120V Lutron HiLume Dimming
All specifications subject to change without notice.
120V and 277V
Electrical/Dimming (0-10V)
RDA6L INST
For ConTech Lighting New Construction/Remodel LED Recessed Multiple Series: RDA6L
J-Box
INSTALLATION PROCEDURES: 1-HEAD REMODEL UNIT
1. Ensure ceiling material is strong enough to support the fixture;
1-head = 12lbs
2. Locate the Hex Key and remove four (4) hex screws located inside the
housing.
3. Remove housing from mounting frame.
4. Locate the four (4) screws holding the junction box to the mounting
frame and remove the junction box from the mounting frame.
5. Insert mounting frame through ceiling cutout.
6. Insert junction box through ceiling cutout and mounting frame
opening, replace screws to secure junction box to mounting frame.
7. Secure mounting frame to supporting structure as needed.
8. Insert housing through ceiling opening and mounting frame, replace
hex screws to secure housing to frame.
9. Refer to trim installation section.
Flexible Conduit
Housing
Mounting
Frame
RL-KIT #3
Trim Frame
Head Tilt Locking Screw
Hex Head
Screws (4)
INSTALLATION PROCEDURES:
2, 3, 4, AND 2X2 REMODEL UNITS
1. Ensure ceiling material is strong enough to support the fixture:
2-head = 17lbs
3-head = 24lbs
4-head = 28lbs
4-head 2x2 = 27lbs
2. Locate the Hex Key and remove four (4) hex screws located inside the
housing
3. Remove housing from mounting frame.
4. Locate the four (4) screws holding the junction box to the mounting
frame and remove the junction box from the mounting frame OR
disconnect the driver output wires in the junction box and remove the
conduit connector from junction box (take note of connections).
5. Insert mounting frame through ceiling cutout.
6. Insert junction box through ceiling cutout and mounting frame
opening, replace screws to secure junction box to mounting frame OR
reattach the conduit connector to the junction box and connect the
driver output wires.
7. Secure mounting frame to supporting structure as needed.
8. Insert housing through ceiling opening and mounting frame, replace
hex screws to secure housing to frame.
9. Refer to trim installation section.
LED DRIVER REPLACEMENT
NOTE: LED Driver should be replaced by a qualified electrician. Turn off
power at fuse or circuit breaker box before replacing the LED Driver.
1. Remove four (4) hex screws that secure the housing to the mounting
frame. Either push housing into plenum space or drop it down through
mounting frame to access junction box.
2. Driver(s) is mounted to junction box cover. Remove junction box cover
by disengaging support spring.
3. Disconnect driver wiring in junction box (take note of connections).
Remove driver from junction box cover.
4. Replace driver on junction box cover and wire new driver in same
fashion as old driver.
5. Reinstall housing into mounting frame.
1-847-559-5500
www.contechlighting.com
All specifications subject to change without notice.