For the ConTech Lighting DL Series LED Linear Display Fixture:... Parts to prepare: INSTALLATION PROCEDURES

advertisement
For the ConTech Lighting DL Series LED Linear Display Fixture: DL34, DL46, DL58, DL70
INSTALLATION PROCEDURES
Parts to prepare:
Base Plate: 1 piece
Terminal A: 1 piece
Terminal B: 1 piece
Cover: 1 piece
Screws: 4 pieces
LED Strip: 1 piece
Cutting:
5/32"
Base Plate
2-23/32"
Cover
Install the showcase light module:
Grooved Side
Smooth Side
Remove the paper from the double-sided adhesive
on the printed circuit board (PCB)
Adhere to grooved side of base plate
Continued
All specifications subject to change without notice.
1-847-559-5500
www.contechlighting.com
This document can be recycled.
DL INST
For the ConTech Lighting DL Series LED Linear Display Fixture: DL34, DL46, DL58, DL70
INSTALLATION PROCEDURES
4
Install the plug-in component:
Terminal B
Remove the release paper on the PCB
5
Install Terminal B:
Slide Terminal B onto the end of the base plate with showcase
light module installed. Hide cables within the terminal.
6
Insert self tapping screws and securely tighten
Mount the Cover:
Slide cover into groves as shown
7
Connect the PCB to the showcase light module
Push cover into Terminal B
Install Terminal A:
Slide Terminal A onto the end of the base plate with showcase
light module installed.
Insert self tapping screws and securely tighten
IMPORTANT SAFETY INSTRUCTIONS:
• Read all the instructions before installation. Save instructions for later use.
• Turn off power at fuse or circuit breaker box before installation or before doing any maintenance work.
• Product must be grounded to avoid potential electric shock and any other potential hazards.
• Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in compliance with National Electrical Code and local
codes. Use of accessory equipment is not recommended.
• Installing contrary to instructions may cause unsafe conditions.
• Do not block light from the trim aperture, in whole or in part, as this may cause unsafe conditions.
• Warning: Risk of fire. Most dwellings built before 1985 have supply wire rated at 60°C. Consult a qualified electrician before installation.
• Avoid hazards to children: account for all parts and properly dispose of all packing materials.
• Call the Technical Support department at Con-Tech Lighting with any installation questions: 847.559.5500
1-847-559-5500
www.contechlighting.com
This document can be recycled.