1 2 3 4 5 NOT FOR CONSTRUCTION AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) DATE: AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 1 MARCH 2015 C SHEET INDEX B 1/6/2015 8:55:25 AM A G-000 PROJECT INFORMATION A-100'S PLANS A-101 VISITORS CENTER - PLAN A A-102 VISITORS CENTER - PLAN A A-103 VISITORS CENTER - PLAN B A-104 VISITORS CENTER - PLAN B A-105 GATEHOUSE / ID CHECK (HIGH VOLUME) A-106 GATEHOUSE / ID CHECK (HIGH VOLUME) A-107 GATEHOUSE / ID CHECK (LOW VOLUME) A-108 POV INSPECTION A-109 COMMERCIAL VEHICLE INSPECTION AND GATEHOUSE (HIGH VOLUME) A-110 COMMERCIAL VEHICLE INSPECTION AND GATEHOUSE (HIGH VOLUME) A-111 COMMERCIAL VEHICLE INSPECTION AND GATEHOUSE (LOW VOLUME) A-112 COMMERCIAL VEHICLE INSPECITON AND GATEHOUSE (LOW VOLUME) A-113 OVERWATCH A-114 OVERWATCH A-115 PEDESTRIAN ENTRY A-116 PEDESTRIAN ENTRY A-200'S SITE PLANS A-201 VISITOR/DoD ENTRY GATE UNCONSTRAINED A-202 VISITOR/DoD PERSONNEL ENTRY GATE CONSTRAINED A-203 DoD PERSONNEL ENTRY GATE UNCONSTRAINED A-204 DoD PERSONNEL ENTRY GATE CONSTRAINED A-205 COMMERCIAL ENTRY GATE UNCONSTRAINED A-206 COMMERCIAL ENTRY GATE CONSTRAINED A-207 VISITOR/DoD/COMMERCIAL ENTRY GATE UNCONSTRAINED A-208 TYPICAL SIGNAGE PLAN ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) D Drawing Title: COVER SHEET & DRAWING INDEX Date: 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-000 D C USE THE DOCUMENT AS A STARTING POINT IN THE DESIGN AND CONSTRUCTION OF A NEW AIR FORCE FACILITY. BUILDING MODULES ARE PROVIDED IN A DIGITAL FORMAT, AS STANDARDS, ALLOWING FUTURE USERS THE ABILITY TO USE THESE FILES WITHIN THEIR BIM SOFTWARE. SITE PLANS ARE PROVIDED AS NOTIONAL EXAMPLES TO BE USED AND ADAPTED TO SPECIFIC SITE REQUIREMENTS. SUPPLEMENTAL DOCUMENTS SUCH AS THE BUILDING PROGRAM, ADJACENCY DIAGRAMS AND DRAWING SETS WITH SITE PLANS ARE PROVIDED IN PORTABLE DOCUMENT FORMAT (PDF) TO ASSIST FUTURE A/E FIRMS IN THE DEVELOPMENT OF THEIR PROJECT. THE MODULES HAVE BEEN DESIGNED WITH THE CONCURRENCE OF THE USERS AND PARTICIPATING AFSFC SUBJECT MATTER EXPERTS (SME) FOR TYPICAL BASE ENTRIES. THE ECF/ACP STRUCTURES ARE AN INDIVIDUAL MODULE THEMSELVES. ANY RECONFIGURATION OF THE MODULES MUST MEET THE REQUIREMENTS OF THE BASE USER AND BE APPROVED BY AFCEC. BUILDING SUPPORT SPACES, INCLUDING BUT NOT LIMITED TO RESTROOMS, JANITORS CLOSETS, AND MECHANICAL/ELECTRICAL ROOMS HAVE BEEN INCLUDED IN THE MODULES FOR REFERENCE. THESE SPACES ALONG WITH DAYLIGHTING OF INTERIOR SPACES, IAW THE REQUIREMENTS OF UFC 1-200-02, HIGH PERFORMANCE AND SUSTAINABLE BUILDING REQUIREMENTS, SHOULD BE REEVALUATED BASED ON THE FINAL SIZE AND CONFIGURATION OF THE FACILITY. THE A/E SHOULD FURTHER CONSIDER DEVELOPING ROOM DATA INFORMATION TO ENSURE ALL OPERATIONAL REQUIREMENTS ARE MET WITHIN EACH SPACE. B AIR FORCE CORPORATE DESIGN POLICY DESIGN FACILITIES TO REPRESENT THEIR TYPE OF USE AND TO ALLOW FOR MULTIPLE ADAPTATIONS OVER TIME. RELATE THE DURABILITY AND REFINEMENT OF DETAILING FOR MATERIALS AND FINISHES TO A FACILITY’S GROUP DESIGNATION. FACILITIES ARE CLASSIFIED IN EITHER GROUPS 1, 2, 3 OR 4 WHICH ARE BASED ON SIMILAR FACILITIES CLASSIFICATIONS FOUND IN AFMAN 32-1084. ECP/IACP FACILITIES ARE CONSIDERED GROUP 1 AND WILL HAVE HIGHER QUALITY FINISHES AND MATERIALS THAN GROUPS 2 OR 3. SUSTAINABILITY FULLY INCORPORATE THE REQUIREMENTS OF UFC 1-200-02, HIGH PERFORMANCE AND SUSTAINABLE BUILDING REQUIREMENTS, AND ACHIEVE GREEN BUILDING CERTIFICATION IAW WITH THE CURRENT AF SUSTAINABLE DESIGN AND DEVELOPMENT POLICY. ANALYZE CLIMATE AND LOCAL AND REGIONAL CONTEXTS; RESPOND TO THESE IN THE BUILDING DESIGN AND PROPERLY ORIENT ECP/IACP BUILDINGS. EVALUATE THE BUILDING COMPONENTS TO DETERMINE WHETHER PASSIVE AND NATURAL DESIGN STRATEGIES AND FEATURES ARE COST EFFECTIVE. RESPOND TO SITE ANALYSIS FOCUSING ON BUILDING ORIENTATION, CONFIGURATION AND MASSING AND DESIGN BUILDINGS REDUCE THE TOTAL OWNERSHIP COSTS OF ECP/IACPS THROUGH THE DESIGN OF HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS. BALANCE LIFE-CYCLE COSTS, ENERGY EFFICIENCY AND OCCUPANT BENEFITS WITH BUDGETS AND MISSION REQUIREMENTS. DESIGN ARCHITECTURAL FEATURES USING SIMPLE DETAILING TO CREATE A PROFESSIONAL APPEARANCE. COMPLY WITH THE ESTABLISHED INSTALLATION DESIGN THEME THROUGH RECURRING ROOF SYSTEMS, WALL SYSTEMS AND BUILDING ENTRANCES THAT REFLECTS ARCHITECTURAL COMPATABILITY WITH THE BASE STANDARDS. PERTINENT DOCUMENTS THE FOLLOWING IS A SUMMARY OF THE PRIMARY DOCUMENTS GOVERNING THE DESIGN OF ECF/ACP. FINAL DESIGN SHALL COMPLY WITH ALL FEDERAL, AND APPLICABLE STATE REGULATIONS. 1/6/2015 8:58:36 AM A 3 • Air Force Manual 32-1084 • UFC 2-100-01: Installation Master Planning • UFC 4-010-01: DoD Minimum Antiterrorism Standards for Buildings • UFC 4-010-02: DoD Minimum Antiterrorism Standoff Distances for Buildings • UFC 4-022-01: Security Engineering - Entry Control Facilities / Access Control Points • UFC 4-022-02: Selection and Application of Vehicle Barriers • SDDCTEA Pamphlet 55-15: Traffic and Safety Engineering for Better Entry Control Facilities • UFGS 34 41 26.00: Unified Facilities Guide Specifications ACP Control System • UFGS 34 71 13.19: Unified Facilities Guide Specifications Active Vehicle Barriers • UFC 1-200-01: General Building Requirements • UFC 1-200-02: High Performance and Sustainable Building Requirements • AF Corporate Facilities Standards 4 5 NOT FOR CONSTRUCTION PROJECT INFORMATION SCOPE OF FACILITY ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) SERVE AS THE ENTRY POINT FOR ALL PERSONNEL, VISITORS, AND DELIVERIES TO THE BASE. THE OBJECTIVE OF THE ECP/IACP IS TO PREVENT UNAUTHORIZED ACCESS. THE PRIORITIES ARE SECURITY, SAFETY, CAPACITY AND IMAGE. STANDARD SITE PLAN NOTES 1. DESCRIPTION OF DRAWINGS PLANS: BUILDING PROGRAM OF THE MAIN FACILITY TYPES IDENTIFIED FOR A TYPICAL ECF/IACP. SITE PLANS: NOTIONAL SITE ELEMENTS AND BUILDING PROGRAM ARE INCORPORATED AT ALL GATE INSTALLATIONS. SPECIFIC CIRCULATION DESIGN LINKS ALL OF THESE ELEMENTS. 2. GENERAL NOTES 3. 1. 2. 3. 4. 5. THESE "GENERAL" NOTES APPLY AND PERTAIN TO ALL SHEETS. USE THESE DOCUMENTS ALONG WITH THE PROGRAM AND OTHER SUPPORTING DOCUMENTS. ALL FUTURE FACILITIES SHALL COMPLY WITH CURRENT AF REGULATIONS, INCLUDING BUT NOT LIMITED TO AFMAN 32-1084, CURRENT AND APPLICABLE UFC, AND AT/FP REQUIREMENTS. FIRE SUPPRESSION SYSTEMS ARE NOT SHOWN ON INDIVIDUAL PLANS AND SHALL BE DESIGNED IN ACCORDANCE WITH NFPA AND OTHER APPLICABLE CODES MECHANICAL (HVAC), ELECTRICAL, AND PLUMBING SYSTEMS SHOWN ARE FOR REFERENCE ONLY AND SHALL BE DESIGNED IN ACCORDANCE WITH APPLICABLE CODES. MECHANICAL AND ELECTRICAL ROOM SIZES ARE APPROXIMATIONS ONLY. 4. 5. THE INSTALLATION ACCESS CONTROL POINTS PLANS HAVE BEEN DEVELOPED AS AN EXAMPLE OF A FULLY INTEGRATED FACILITY DEPICTED ON AN ARBITRARY SITE. ACTUAL SITE CONDITIONS SHALL BE ASSESSED AGAINST OPERATIONS ALONG WITH OTHER CRITERIA THAT MAY IMPACT EXISTING BUILDING MASSING, ENVIRONMENT, AND INFRASTRUCTURE. INFORMATION GATHERED THROUGH THESE ASSESSMENTS WILL IMPACT THE ACTUAL FACILITY AND SITE CONFIGURATION. THE MODULES ARE DYNAMIC, ALLOWING THE USER TO FLEX AND ORGANIZE FOR THEIR SPECIFIC MISSION NEEDS. HYDROLOGY, INCLUDING STORM WATER QUALITY/QUANTITY MITIGATION (DETENTION OR RETENTION PONDS) IAW UFC 1-200-02,HIGH PERFORMANCE AND SUSTAINABLE BUILDING REQUIREMEMTS HAS NOT BEEN CONSIDERED FOR THESE CONCEPTUAL SITE PLANS. LANDSCAPE PLANS SHALL BE IN ACCORDANCE WITH UFC 4-022-01. LANDSCAPE SHALL ENHANCE THE BASE ENVIRONMENT AND EMPHASIZE THE PUBLIC ENTRANCE BY UTILIZING NATIVE OR ADAPTIVE SPECIES WHILE NOT OBSTRUCTING MISSION CRITICAL VIEWS. ROAD SPEED MANAGEMENT DESIGN PER SDDCTEA PAMPHLET 55-15 AND UFC 4-022-01. ADDITIONAL DESIGN LAYOUTS AVAILABLE IN SDDCTEA PAMPHLET 55-15. STANDARD BUILDING PLAN NOTES 1. 2. 3. 4. DIMENSIONS ARE APPROXIMATE AND MUST BE ADJUSTED TO ACCOUNT FOR BASE SPECIFIC STANDARDS AND FINISHES. MAINTAIN PROGRAMMATIC AREA AND ADJACENCY REQUIREMENTS. UNLESS SPECIFICALLY NOTED OTHERWISE, WALLS, CEILINGS, AND FLOORS, INCLUDING THEIR COMPOSITION AND DIMENSIONS, ARE MODELED GENERICALLY, AS “PLACE HOLDERS”. CONSIDERATION SHOULD BE GIVEN BUT NOT LIMITED TO, SOUND TRANSMISSION & ABSORPTION (STC/NRC), FIRE RATINGS, THERMAL INSULATION, MATERIALITY, SECURITY, ETC. FURNITURE AND EQUIPMENT SHOWN IS FOR REFERENCE PURPOSES, FINAL REQUIREMENTS MAY DIFFER. COORDINATE SPECIFIC & FINAL REQUIREMENTS WITH THE AIR FORCE. ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) PROJECT GUIDE SCOPE AND USE 2 AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 1 Drawing Title: PROJECT INFORMATION Date: 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT G-000 3 4 5 NOT FOR CONSTRUCTION NOTES 1. 52' - 0" 2. D 3. FEC 4. 4'-8" MIN. SCREEN WALL ADMINISTRATION 5. 6. OUTDOOR PATIO BREAK / COPY EQUIPMENT CHARGING STATION BENCH COFFEE BAR AC CONDENSER C ID CHECKING 42" HIGH COUNTER & STORAGE 4' - 6" DBIDS PRINTER STORAGE ACCESSIBLE COUNTER VESTIBULE PHOTO BACKDROPS 3' - 3" 52' - 0" EXTERIOR WALK-OFF MAT COVERED ENTRY JAN MECH / ELEC 42" HIGH COUNTER DISPLAY WALL MEN LOBBY HALF-HEIGHT CASEWORK FEC VENDING B IT/COM SIGN-IN KIOSK / TICKET NUMBER WAITING WATER COOLERS WOMEN DETERMINE PROCESSING CAPACITY AND PARKING BY THE PEAK HOURLY REQUIREMENTS AS DEFINED BY AN SDDC TRAFFIC STUDY. PROVIDE PHOTO ID CAPABILITY AT PROCESSING STATION WITH A PHOTO BACKDROP. PROVIDE CONDUIT AND WIRING AT EACH PROCESSING STATION FOR A DURESS ALARM. PROVIDE ACCESS TO NATIONAL CRIME INFORMATION CENTER (NCIC) AT EACH PROCESSING STATION. PROVIDE DEFENSE BIOMETRIC IDENTIFICATION SYSTEM (DBIDS) TERMINAL AT ID CHECKING. ALL STANDARD COUNTERTOPS ARE 36" A.F.F. UNLESS NOTED OTHERWISE. PEAK HOURLY DEMAND (BASIS OF DESIGN) PEAK HOURLY REQUIREMENTS: ASSUMED 40 PEOPLE ID CHECKING PROCESSING TIME: 12-20 VISITORS / HR INTERIOR FINISHES ADMINISTRATION & BREAK/COPY FLOOR: SEALED / STAINED CONCRETE OR CARPET TILE BASE: TILE OR RUBBER BASE WALLS: HIGH IMPACT GYPSUM BOARD (GB) AND PAINT CEILING: ACT OR GB (MIN. 9'-0" AFF) OR OPEN TO STRUCTURE LOBBY, WAITING & ID CHECKING FLOOR: SEALED / STAINED CONCRETE OR TILE BASE: TILE OR RUBBER BASE WALLS: GYPSUM BOARD (GB) AND PAINT CEILING: ACT OR GB (MIN. 9'-0" AFF) OR OPEN TO STRUCTURE CASEWORK: HIGHLY DURABLE MATERIALS TOILETS FLOOR: BASE: WALLS: CEILING: BENCH TV LEGEND: FEC VISITOR ENTRY SEQUENCE A 1/6/2015 8:55:39 AM RECESSED OR SEMI-RECESSED FIRE EXTINGUISHING CABINENT (UNLESS COVERED IN THE RFP) 0 4' 8' SCALE: 1/8 " = 1' 16' SUPPORT SPACES (STORAGE, JC, IT/COMM, MECH) FLOOR: FINISHED CONCRETE OR VCT BASE: RUBBER BASE WALLS: HIGH IMPACT GYPSUM BOARD (GB) AND PAINT CEILING: ACT, GB (MIN. 9'-0" AFF), OR OPEN TO STRUCTURE VESTIBULE FLOOR: BASE: WALLS: CEILING: VISITORS CENTER - PLAN A SQUARE FOOTAGE (REFERENCE PROGRAM) MODULE = 2,004 GSF TILE TILE BASE GYPSUM BOARD (GB) AND PAINT WITH TILE WAINSCOT ACT OR GB (MIN. 9'-0" AFF) SEALED / STAINED CONCRETE OR TILE RUBBER BASE GYPSUM BOARD (GB) AND PAINT ACT, GB (MIN. 9'-0" AFF), OR OPEN TO STRUCTURE ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) 2 AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 1 Drawing Title: VISITORS CENTER - PLAN A Date: 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-101 1 2 3 4 5 NOTES 1. NOT FOR CONSTRUCTION COMPLY WITH BASE DESIGN STANDARDS / ARCHITECTURAL COMPATIBILITY PLANS AND AFCFS. C B ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: D Drawing Title: VISITORS CENTER - PLAN A 1/6/2015 8:56:02 AM A VISITORS CENTER - PLAN A (NOTIONAL MASSING) Date: 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-102 3 4 5 NOT FOR CONSTRUCTION NOTES 1. 2. D 55' - 0" 3. 4. 5. AC CONDENSER MEN WOMEN JANITOR MECH / ELEC 6. WATER COOLERS C 7. DBIDS PRINTER PHOTO BACKDROPS TV 3' -. 9" LOBBY 4' .- 0" PEAK HOURLY DEMAND (BASIS OF DESIGN) PEAK HOURLY REQUIREMENTS: ASSUMED 40 PEOPLE ID CHECKING PROCESSING TIME: 12-20 VISITORS / HR EQUIPMENT CHARGING STATION ID CHECKING SIGN-IN KIOSK / TICKET NUMBER COFFEE BAR ADMINISTRATION WAITING HALF-HEIGHT CASEWORK BREAK / COPY 43' - 0" DISPLAY WALL ACCESSIBLE COUNTER 42" HIGH COUNTER FEC 4'-8" MIN. SCREEN WALL VENDING STORAGE IT/COM TOILETS FLOOR: BASE: WALLS: CEILING: EXTERIOR WALK-OFF MAT ENTRY COVERED ENTRY LEGEND: FEC RECESSED OR SEMI-RECESSED FIRE EXTINGUISHING CABINENT (UNLESS COVERED IN THE RFP) VISITOR ENTRY SEQUENCE A 1/6/2015 8:56:13 AM ALT ENTRY 4' 8' SCALE: 1/8 " = 1' 16' SQUARE FOOTAGE (REFERENCE PROGRAM) PLAN = 2,042 GSF TILE TILE BASE GYPSUM BOARD (GB) AND PAINT ACT OR GB (MIN. 9'-0" AFF) SUPPORT SPACES (STORAGE, JC, IT/COMM, MECH) FLOOR: FINISHED CONCRETE OR VCT BASE: RUBBER BASE WALLS: HIGH IMPACT GYPSUM BOARD (GB) AND PAINT CEILING: ACT OR GB (MIN. 9'-0" AFF) OR OPEN TO STRUCTURE VESTIBULE FLOOR: VISITORS CENTER - PLAN B 0 INTERIOR FINISHES ADMINISTRATION & BREAK/COPY FLOOR: SEALED / STAINED CONCRETE OR CARPET TILE BASE: TILE OR RUBBER BASE WALLS: HIGH IMPACT GYPSUM BOARD (GB) AND PAINT CEILING: ACT OR GB (MIN. 9'-0" AFF) OR OPEN TO STRUCTURE LOBBY, WAITING & ID CHECKING FLOOR: SEALED / STAINED CONCRETE OR VCT BASE: TILE OR RUBBER BASE WALLS: GYPSUM BOARD (GB) AND PAINT CEILING: ACT OR GB (MIN. 9'-0" AFF) OR OPEN TO STRUCTURE CASEWORK: HIGHLY DURABLE MATERIALS STORAGE & SUPPORT SYSTEMS B VESTIBULE DETERMINE PROCESSING CAPACITY AND PARKING BY THE PEAK HOURLY REQUIREMENTS AS DEFINED BY AN SDDC TRAFFIC STUDY. PROVIDE PHOTO ID CAPABILITY AT PROCESSING STATION WITH A PHOTO BACKDROP. PROVIDE CONDUIT AND WIRING AT EACH PROCESSING STATION FOR A DURESS ALARM. PROVIDE ACCESS TO NATIONAL CRIME INFORMATION CENTER (NCIC) AT EACH PROCESSING STATION. PROVIDE DEFENSE BIOMETRIC IDENTIFICATION SYSTEM (DBIDS) TERMINAL AT ID CHECKING. THE USE OF THE ALTERNATE ADMINISTRATION LAYOUT IS TO BE DETERMINED BY BASE MISSION NEEDS. OPEN OFFICE CONFIGURATION PREFERRED FOR FUTURE DESIGN FLEXIBILITY. ALL STANDARD COUNTERTOPS ARE 36" A.F.F. UNLESS NOTED OTHERWISE. BASE: WALLS: CEILING: ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) 2 AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 1 SEALED / STAINED CONCRETE OR TILE RUBBER BASE GYPSUM BOARD (GB) AND PAINT ACT OR GB (MIN. 9'-0" AFF) OR OPEN TO STRUCTURE Drawing Title: VISITORS CENTER - PLAN B Date: 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-103 1 2 3 4 5 NOTES 1. NOT FOR CONSTRUCTION COMPLY WITH BASE DESIGN STANDARDS / ARCHITECTURAL COMPATIBILITY PLANS AND AFCFS. C B ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: D Drawing Title: VISITORS CENTER - PLAN B 1/6/2015 8:56:23 AM A VISITORS CENTER - PLAN B (NOTIONAL MASSING) Date: 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-104 3 4 5 NOTES 1. TRAFFIC CONTROL DROP ARM D 4'-8" SCREEN WALL AC CONDENSER STAND-BY PORABLE GENERATOR UNDER COUNTER REFRIGERATOR TR STOR 13' - 4" TOILET BARRIER CONTROL PANEL BREAK GATEHOUSE 5' - 0" DBIDS TERMINAL / PRINTER ID CHECK 3. 3' - 6" WALKWAY FROM VISITOR CENTER 7' - 0" ID CHECK 31' - 0" 2. EQUIPMENT CHARGING DUTY WEAPON STORAGE (ABOVE) 4. 5. C 7' - 0" 21' - 0" ID CHECK 9' - 0" 18' - 0" ID CHECK 7. 85' - 0" 1' - 0" 4' - 0" LANE 1 3' - 0" LANE OPEN/CLOSE SIGNAGE ABOVE INBOUND LANE . 10' - 0" 6. 6" RAISED CURB (TYP) LANE 2 INBOUND LANE . 8. 9. 10. COUNTER 11. B 10' - 0" ID CHECK 30' - 0" 8' - 0" ID CHECK 10' - 11" 12. 13. INBOUND LANE . A CRASH ATTENUATORS (TYP) 2' CLEAR TRAFFIC CONTROL GATES LANE 3 PORTABLE TRAFFIC CONTROL DEVICE STORAGE 12' - 0" 24' - 0" WIND SCREEN WHEN LOCAL CONDITIONS WARRANT CANOPY ABOVE 14. 15. NOT FOR CONSTRUCTION ID CHECKING AREA SHALL BE COVERED AND PROTECTED FROM THE ELEMENTS. ACTUAL CANOPY DESIGN TO BE CONFIRMED WITH BASE. VISUAL/DESIGN INTEGRATION OF THE LANE CLOSURE SIGNAGE IS REQUIRED. DIMENSIONS ARE NOT ABSOLUTE; BASED ON THE UFC 4-022-01 (SECURITY ENGINEERING: ENTRY CONTROL FACILITIES / ACCESS CONTROL POINTS), SDDCTEA PAMPHLET 55-15 (TRAFFIC AND SAFETY ENGINEERING FOR BETTER ENTRY CONTROL FACILITIES), AND ENTRY CONTROL FACILITY DESIGN GUIDE. DUTY WEAPONS STORAGE AND EQUIPMENT CHARGING STATIONS LOCATED ABOVE STORAGE CABINETS. PROVIDE ACCESS TO NATIONAL CRIME INFORMATION CENTER (NCIC) AT EACH ID CHECK STATION. PROVIDE UNDER COUNTER REFRIGERATOR, SINK AND MICROWAVE AT BREAK COUNTER. HVAC: DUCTLESS SPLIT-SYSTEM SHOWN; PACKED TERMINAL AIR CONDITIONER (P-TAC) WOULD BE AN ACCEPTABLE ALTERNATIVE. LANE CLOSURE MAY BE ACHIEVED WITH TRAFFIC CONTROL DROP ARMS, BOLLARDS, OPERABLE GATES OR OTHER AIR FORCE APPROVED SYSTEM (REFERENCE UFC 4-022-02). PROVIDE DRAINAGE UNDER CANOPY TO PREVENT STANDING WATER. PROVIDE BALLISTIC PROTECTION EQUIVALENT TO UL 752 LEVEL III AT EXTERIOR ENVELOPE (WINDOWS, DOORS, WALLS AND OTHER EQUIPMENT). PROVIDE TRANSFER SWITCH AT BUILDING EXTERIOR FOR PORTABLE STAND-BY GENERATOR PER AFI 32-1063. COORDINATE WITH FINAL DENIAL CAPABILITY. CROSSWALK LOCATION TO BE DETERMINED BY SITE CIRCULATION REQUIREMENTS. PROVIDE SNOW & ICE MELTING SYSTEM WITH REQUIRED DRAINAGE (COLD CLIMATE CONDITIONS). ALL STANDARD COUNTERTOPS ARE 36" A.F.F. UNLESS NOTED OTHERWISE. PROVIDE INDIRECT LIGHTING UNDER CANOPY NO EXPOSED CONDUIT OR WIRING IN ID CHECK STATIONS ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) 2 AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 1 Drawing Title: GATEHOUSE / ID CHECK (HIGH VOLUME) 1/6/2015 8:56:34 AM 70' - 0" GATEHOUSE / ID CHECK (HIGH VOLUME) 0 4' 8' 16' SCALE: 3/32 " = 1' Date: SQUARE FOOTAGE (REFERENCE PROGRAM) MODULE = 467 GSF CANOPY = 5,880 GSF / ID CHECK = 36 GSF 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-105 1 2 3 4 5 NOT FOR CONSTRUCTION NOTES D STORAGE FLOOR: BASE: WALLS: CEILING: C AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: TOILET FLOOR: TILE BASE: TILE BASE WALLS: GYPSUM BOARD (GB) AND TILE WAINSCOT CEILING: ACT OR GB (MIN. 9'-0" AFF) SEALED / STAINED CONCRETE OR TILE RUBBER BASE GYPSUM BOARD (GB) ACT OR GB (MIN. 9'-0" AFF) ID CHECK (BOOTH) FLOOR: SEALED / STAINED CONCRETE OR TILE BASE: RUBBER BASE WALLS: RIGID HIGH IMPACT WALL COVERING OVER HIGH IMPACT GYPSUM SHEATHING CEILING: ACT OR GB (MIN. 9'-0" AFF) FUNCTIONAL REQUIREMENTS ID CHECK (BOOTH) - BARRIER CONTROL ACTIVATION, BASE SPECIFIC - CONVENIENCE OUTLET (BOOTH INTERIOR) - EXTERIOR POWER FOR WALL MOUNTED FAN - RADIANT HEAT SOURCE (COLD CLIMATE LOCATION) - DBIDS ANTENNA - STAINLESS STEEL COUNTER B ID CHECK LANES - CONCRETE WITH CURB AND GUTTER - MINIMUM CLEAR HEIGHT 14'-6" CLEAR AT DRIVE LANES - CANOPY MOUNTED LANE NUMBER AND LANE USE SIGNAL VISUALLY INTEGRATED INTO OVERALL CANOPY DESIGN ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) INTERIOR FINISHES GATEHOUSE FLOOR: SEALED / STAINED CONCRETE OR TILE BASE: RUBBER BASE WALLS: RIGID HIGH IMPACT WALL COVERING OVER HIGH IMPACT GYPSUM SHEATHING CEILING: ACT OR GB (MIN. 9'-0" AFF) Drawing Title: GATEHOUSE / ID CHECK (HIGH VOLUME) 1/6/2015 8:56:45 AM A GATEHOUSE / ID CHECK (NOTIONAL MASSING) Date: 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-106 3 4 5 NOTES 1. D OUTBOUND LANE 2. TRAFFIC CONTROL DROP ARM (BOLLARDS OPTIONAL) 4'-8" SCREEN WALL STAND-BY GENERATOR AC CONDENSER UNDER COUNTER REFRIGERATOR TR 3. 4. CRASH ATTENUATOR (TYP) BREAK STORAGE C 5. 3' - 6" BARRIER CONTROL PANEL 13' - 4" TOILET DBIDS TERMINAL / PRINTER 31' - 0" 6. DUTY WEAPON STORAGE (ABOVE) 7. 7' - 0" ID CHECK WALKWAY FROM VISITOR CENTER EQUIPMENT CHARGING 66' - 0" LANE 1 TRAFFIC FLOW . 10' - 0" 8. 6" RAISED CURB (TYP) 9' - 0" B TRAFFIC FLOW . LANE OPEN/CLOSE SIGNAGE ABOVE INTEGRATED WITH DESIGN LANE 2 6" RAISED CURB (TYP) 11. 12. 12' - 0" ID CHECK 8' - 0" 10. 3' - 0" 4' - 0" COUNTER 9. 13. 14. 15. CRASH ATTENUATORS (TYP) NOT FOR CONSTRUCTION ID CHECKING AREA SHALL BE COVERED AND PROTECTED FROM THE ELEMENTS. ACTUAL CANOPY DESIGN TO BE CONFIRMED WITH BASE. VISUAL/DESIGN INTEGRATION OF THE LANE CLOSURE SIGNAGE IS REQUIRED. DIMENSIONS ARE NOT ABSOLUTE; BASED ON THE UFC 4-022-01 (SECURITY ENGINEERING: ENTRY CONTROL FACILITIES / ACCESS CONTROL POINTS), SDDCTEA PAMPHLET 55-15 (TRAFFIC AND SAFETY ENGINEERING FOR BETTER ENTRY CONTROL FACILITIES), AND ENTRY CONTROL FACILITY DESIGN GUIDE. DUTY WEAPONS STORAGE AND EQUIPMENT CHARGING STATIONS LOCATED ABOVE STORAGE CABINETS. PROVIDE ACCESS TO NATIONAL CRIME INFORMATION CENTER (NCIC) AT EACH ID CHECK STATION. PROVIDE UNDER COUNTER REFRIGERATOR, SINK AND MICROWAVE AT BREAK COUNTER. HVAC: DUCTLESS SPLIT-SYSTEM SHOWN; PACKED TERMINAL AIR CONDITIONER (P-TAC) WOULD BE AN ACCEPTABLE ALTERNATIVE. LANE CLOSURE MAY BE ACHIEVED WITH TRAFFIC CONTROL DROP ARMS, BOLLARDS, OPERABLE GATES OR OTHER AIR FORCE APPROVED SYSTEM (REFERENCE UFC 4-022-02). PROVIDE DRAINAGE UNDER CANOPY TO PREVENT STANDING WATER. PROVIDE BALLISTIC PROTECTION EQUIVALENT TO UL 752 LEVEL III AT EXTERIOR ENVELOPE (WINDOWS, DOORS, WALLS AND OTHER EQUIPMENT). PROVIDE TRANSFER SWITCH AT BUILDING EXTERIOR FOR PORTABLE STAND-BY GENERATOR PER AFI 32-1063. COORDINATE WITH FINAL DENIAL CAPABILITY. CROSSWALK LOCATION TO BE DETERMINED BY SITE CIRCULATION REQUIREMENTS. PROVIDE SNOW & ICE MELTING SYSTEM WITH REQUIRED DRAINAGE (COLD CLIMATE CONDITIONS). ALL STANDARD COUNTERTOPS ARE 36" A.F.F. UNLESS NOTED OTHERWISE. PROVIDE INDIRECT LIGHTING UNDER CANOPY NO EXPOSED CONDUIT OR WIRING IN ID CHECK STATIONS ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) 2 AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 1 PORTABLE TRAFFIC CONTROL DEVICE STORAGE (IF GATES NOT UTILIZED) WIND SCREEN WHEN LOCAL CONDITIONS WARRANT Drawing Title: CANOPY ABOVE 48' - 6" GATEHOUSE / ID CHECK (LOW VOLUME) 1/6/2015 8:56:53 AM A GATEHOUSE / ID CHECK (LOW VOLUME) 0 4' 8' SCALE: 3/32 " = 1' 16' Date: SQUARE FOOTAGE (REFERENCE PROGRAM) MODULE = 440 GSF CANOPY = 3,201 GSF / ID CHECK = 36 GSF 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-107 1 2 3 4 5 NOTES NOT FOR CONSTRUCTION 29' - 0" 33' - 6" C ADDITIONAL 2ND BAY (IF REQUIRED BY TRAFFIC STUDY) INSPECTION BAY SINGLE BAY VEHICLE INSPECTION AREA (MIN 17'-0" x 29'-0") 17' - 0" DASHED LINE INDICATES WALL FOR A SINGLE BAY OPTION 44' - 0" PROTECTIVE BOLLARD (TYP) DOUBLE BAY COILING ROLL-UP DOOR, (TYP) (12' x 14') WITH SMALL VIEW PANEL INTERIOR FINISHES STORAGE & WAITING FLOOR: FINISHED SEALED CONCRETE OR VCT BASE: RUBBER BASE WALLS: GYPSUM BOARD (GB) PAINTED CEILING: ACT OR GB (MIN. 9'-0" AFF) FINAL BARRIER CONTROL ACTIVATION B WORKSTATION EQUIPMENT CHARGING STATION EQUIPMENT STORAGE INSPECTION BAY FLOOR: CONCRETE BASE: RAISED 6" CONCRETE CURB WALLS: EXPOSED STRUCTURE - INSULATED DURABLE LINER PANELS IN COLD CLIMATES CEILING: EXPOSED STRUCTURE - VINYL FACED INSULATION IN COLD CLIMATES (MIN. 14'-6" AFF) DRIVER WAITING K-9 CALMING INSPECTION EQUIPMENT STORAGE AC CONDENSER 1-WAY VISION GLASS SECURITY FORCE VEHICLE WALKWAY TO VISITORS CENTER 1/6/2015 8:57:04 AM Drawing Title: 4'-8" SCREEN WALL A POV INSPECTION POV INSPECTION 0 4' 8' SCALE: 1/8 " = 1' ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) D COVER AND PROTECT VEHICLE INSPECTION AREA FROM THE ELEMENTS. 2. SCREEN VISIBILITY TO PREVENT OBSERVATION OF THE INSPECTION OPERATION. 3. PROVIDE CEILING MOUNTED INSPECTION MIRRORS WITHIN INSPECTION BAY. 4. HVAC: A PACKED TERMINAL AIR CONDITIONER (P-TAC) OR DUCTLESS SPLIT-SYSTEM WOULD BE USED WITHIN THE EQUIPMENT STORAGE/WAITING AREAS AND CEILING MOUNTED UNIT HEATERS OR FANS IN INSPECTION BAYS. 5. PROVIDE VENTILATION IN ACCORDANCE TO ASHRAE TO MITIGATE VEHICLE EXHAUST. 6. PROVIDE LIGHTING IN ACCORDANCE TO ANSI STANDARDS FOR INSPECTION PROCEDURES. 7. DESIGN FOR CURRENT AND FUTURE INSPECTION TECHNOLOGIES (ABOVE VEHICLE SURVEILLANCE SYSTEMS [AVSS], UNDER VEHICLE SURVEILLANCE SYSTEMS [UVSS], ION SCANNING, AND X-RAY EQUIPMENT). 8. LOCATE COMM / IT EQUIPMENT WITHIN THE EQUIPMENT STORAGE ROOM. 9. PROVIDE INTERIOR HOSE BIB FOR WASH DOWN AND DRAINAGE. (NOT SHOWN FOR CLARITY). 10. PROVIDE DOOR ANNUNCIATOR AT DRIVER WAITING. 11. ALL STANDARD COUNTERTOPS ARE 36" A.F.F. UNLESS NOTED OTHERWISE. 12. INSPECTION BAY TO MAINTAIN 14'-6" CLEAR INCLUDING MECHANICAL AND ELECTRICAL. AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 1. Date: 16' SQUARE FOOTAGE (REFERENCE PROGRAM) MODULE = 1,340 GSF 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-108 3 4 5 70' - 0" (80'-0" WHEN INSPECTION PIT IS PROVIDED) DBIDS TERMINAL 1-WAY VISION GLASS UNDER COUNTER REFRIGERATOR NOTES 4'-8" SCREEN WALL 1. STAND-BY PORTABLE GENERATOR COFFEE BAR 2. D IT/COMM SUPPORT EQUIPMENT (STORAGE BELOW) SECURITY FORCES & ESCORT PARKING JANITOR MECH/ELEC GATEHOUSE BREAK 3. 4. TOILET 42" TRANSACTION HEIGHT COUNTER DUTY WEAPON STORAGE FINAL BARRIER CONTROL PANEL DRIVER WAITING AC CONDENSER EQUIPMENT STORAGE C K-9 CALMING CANOPY ABOVE 5. INSPECTION EQUIPMENT CHARGING 6. 7. INSPECTION EQUIPMENT STORAGE 8. FINAL BARRIER CONTROL ACTIVATION 9. INSPECTION BAY #1 (17'-0" x 70'-0" MIN) COILING ROLL-UP DOOR (12' X 14') WITH VIEW PANELS 70'-0" MIN. 17'-0" MIN. REMOVABLE BOLLARDS 11. 12. BOLLARD STORAGE 6" RAISED CURB INSPECTION BAY #2 (17'-0" x 70'-0" MIN) 13. 14. 15. 16. 4' MIN B 10. 4' MIN 52' - 10" 17'-0" MIN. PROTECTIVE BOLLARDS NOT FOR CONSTRUCTION VEHICLE INSPECTION AREA SHALL BE COVERED AND PROTECTED FROM THE ELEMENTS. VEHICLE INSPECTION AREA SHALL SCREEN VISIBILITY TO PREVENT OBSERVATION OF THE INSPECTION OPERATION. PROVIDE CEILING MOUNTED INSPECTION MIRRORS WITHIN INSPECTION BAY. HVAC: A PACKED TERMINAL AIR CONDITIONER (PTAC) OR DUCTLESS SPLIT-SYSTEM WOULD BE USED WITHIN THE GATEHOUSE AND CEILING MOUNTED UNIT HEATERS OR FANS IN INSPECTION BAYS. PROVIDE VENTILATION IN ACCORDANCE TO ASHRAE TO MITIGATE VEHICLE EXHAUST. PROVIDE LIGHTING IN ACCORDANCE TO ANSI STANDARDS FOR INSPECTION PROCEDURES. UNDER CARRIAGE INSPECTION PIT APPROVED BY UFC BUT NOT RECOMMENDED. REFER TO UFC FOR PIT CONFIGURATION IF USED. DESIGN FOR CURRENT AND FUTURE INSPECTION TECHNOLOGIES (ABOVE VEHICLE SURVEILLANCE SYSTEMS [AVSS], UNDER VEHICLE SURVEILLANCE SYSTEMS [UVSS], ION SCANNING, AND X-RAY EQUIPMENT). LOCATE COMM / IT EQUIPMENT WITHIN THE GATEHOUSE ROOM IN THE IT/COMM CLOSET. DUTY WEAPONS STORAGE AND EQUIPMENT CHARGING STATIONS TO BE LOCATED ABOVE STORAGE CABINETS WITH COUNTERTOP HEIGHT OF 42". PROVIDE ACCESS TO NATIONAL CRIME INFORMATION CENTER (NCIC) AT WORKSTATION. SECURITY FORCES WORKSTATION SHALL HAVE A CLOSED-CIRCUIT TELEVISION (CCTV) MONITORING CAPABILITIES. PROVIDE TRANSFER SWITCH AT BUILDING EXTERIOR FOR STAND-BY PORTABLE GENERATOR PER AFI 32-1063. COORDINATE WITH FINAL DENIAL CAPABILITY. SPACE FOR UNDER COUNTER REFRIGERATOR, SINK AND MICROWAVE AT BREAK COUNTER. INTERIOR HOSE BIB FOR WASH DOWN AND DRAINAGE. ALL STANDARD COUNTERTOPS ARE 36" A.F.F. UNLESS NOTED OTHERWISE. ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) 2 AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 1 VEHICLE INSPECTION AREA 4'-0" CLEAR ALL SIDES Drawing Title: TRAFFIC CONTROL DROP ARM (BOLLARDS OPTIONAL) COMMERCIAL VEHICLE INSPECTION AND GATEHOUSE (HIGH VOLUME) 1/6/2015 8:57:19 AM A COMMERCIAL VEHICLE INSPECTION AND GATEHOUSE (HIGH VOLUME) 0 4' 8' SCALE: 1/8 " = 1' 16' Date: SQUARE FOOTAGE (REFERENCE PROGRAM) MODULE = 3,378 GSF 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-109 1 2 3 4 5 NOT FOR CONSTRUCTION NOTES D STORAGE FLOOR: BASE: WALLS: CEILING: C AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: TOILET FLOOR: TILE OR VCT BASE: RUBBER BASE WALLS: GYPSUM BOARD (GB) AND TILE WAINSCOT CEILING: ACT OR GB (MIN. 9'-0" AFF) FINISHED SEALED CONCRETE OR VCT RUBBER BASE GYPSUM BOARD (GB) ACT OR GB (MIN. 9'-0" AFF) B ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) INTERIOR FINISHES GATEHOUSE FLOOR: FINISHED SEALED CONCRETE OR VCT BASE: RUBBER BASE WALLS: DURABLE GYPSUM BOARD (GB) IMPACT RESISTANT W/ PROTECTIVE PANELING CEILING: ACT OR GB (MIN. 9'-0" AFF) Drawing Title: COMMERCIAL VEHICLE INSPECTION AND GATEHOUSE (HIGH VOLUME) 1/6/2015 8:57:29 AM A COMMERCIAL VEHICLE INSPECTION AND GATEHOUSE HIGH VOLUME (NOTIONAL MASSING) Date: 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-110 3 4 5 NOTES 1. 2. D 3. 70' - 0" DUTY WEAPON STORAGE EQUIPMENT CHARGING STATION STAND-BY PORTABLE GENERATOR INSPECTION EQUIPMENT STORAGE DBIDS TERMINAL 4. 4'-3" MIN SCREEN WALL AC CONDENSER SECURITY FORCES & ESCORT PARKING 5. 6. IT/COMM CANOPY ABOVE 7. TOILET K-9 CALMING GATEHOUSE VEHICLE INSPECTION AREA 4'-0" CLEAR ALL SIDES DRIVER WAITING C 8. PASS THROUGH WINDOW 9. INSPECTION BAY (17'-0" x 70'-0" MIN) TRAFFIC FLOW . 17'-0" MIN. 30' - 0" COILING ROLL-UP DOOR (12' X 14') WITH SMALL VIEW PANELS PROTECTIVE BOLLARDS 10. 11. 12. 13. 14. B 15. 70'-0" MIN. 16. NOT FOR CONSTRUCTION VEHICLE INSPECTION AREA SHALL BE COVERED AND PROTECTED FROM THE ELEMENTS. VEHICLE INSPECTION AREA SHALL SCREEN VISIBILITY TO PREVENT OBSERVATION OF THE INSPECTION OPERATION. PROVIDE CEILING MOUNTED INSPECTION MIRRORS WITHIN INSPECTION BAY. HVAC: A PACKED TERMINAL AIR CONDITIONER (PTAC) OR DUCTLESS SPLIT-SYSTEM WOULD BE USED WITHIN THE GATEHOUSE AND CEILING MOUNTED UNIT HEATERS OR FANS IN INSPECTION BAYS. PROVIDE VENTILATION IN ACCORDANCE TO ASHRAE TO MITIGATE VEHICLE EXHAUST. PROVIDE LIGHTING IN ACCORDANCE TO ANSI STANDARDS FOR INSPECTION PROCEDURES. UNDER CARRIAGE INSPECTION PIT APPROVED BY UFC BUT NOT RECOMMENDED. REFER TO UFC FOR PIT CONFIGURATION IF USED. CONSIDER CURRENT AND FUTURE INSPECTION TECHNOLOGIES (ABOVE VEHICLE SURVEILLANCE SYSTEMS [AVSS], UNDER VEHICLE SURVEILLANCE SYSTEMS [UVSS], ION SCANNING, AND X-RAY EQUIPMENT). LOCATE COMM / IT EQUIPMENT WITHIN THE GATEHOUSE ROOM. DUTY WEAPONS STORAGE AND EQUIPMENT CHARGING STATIONS TO BE LOCATED ABOVE STORAGE CABINETS. PROVIDE ACCESS TO NATIONAL CRIME INFORMATION CENTER (NCIC) AT WORKSTATION. SECURITY FORCES WORKSTATION SHALL HAVE A CLOSED-CIRCUIT TELEVISION (CCTV) MONITORING CAPABILITIES. PROVIDE TRANSFER SWITCH AT BUILDING EXTERIOR FOR STAND-BY GENERATOR PER AFI 32-1063. COORDINATE WITH FINAL DENIAL CAPABILITY. PROVIDE UNDER COUNTER REFRIGERATOR, SINK AND MICROWAVE AT BREAK COUNTER. PROVIDE HOSE BIB FOR WASH DOWN AND DRAINAGE. ALL STANDARD COUNTERTOPS ARE 36" A.F.F. UNLESS NOTED OTHERWISE. ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) 2 AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 1 TRAFFIC CONTROL DROP ARM (BOLLARDS OPTIONAL) Drawing Title: BYPASS LANE COMMERCIAL VEHICLE INSPECTION AND GATEHOUSE (LOW VOLUME) 1/6/2015 8:57:41 AM A COMMERCIAL VEHICLE INSPECTION AND GATEHOUSE (LOW VOLUME) 0 4' 8' SCALE: 1/8 " = 1' 16' Date: SQUARE FOOTAGE (REFERENCE PROGRAM) MODULE = 1,763 GSF 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-111 1 2 3 4 5 NOT FOR CONSTRUCTION NOTES D TOILET FLOOR: BASE: WALLS: CEILING: C AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: INSPECTION BAY FLOOR: CONCRETE BASE: RAISED CONCRETE CURB WALLS: EXPOSED STRUCTURE - INSULATED DURABLE LINER PANELS IN COLD CLIMATE UP TO 8' CEILING: EXPOSED STRUCTURE - VINYL FACED INSULATION IN COLD CLIMATE (MIN. 17'-6" AFF - CLEAR) TILE RUBBER BASE GYPSUM BOARD (GB) AND TILE ACT OR GB (MIN. 9'-0" AFF) B ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) INTERIOR FINISHES GATEHOUSE, WAITING, STORAGE & BREAK FLOOR: FINISHED SEALED CONCRETE OR VCT BASE: RUBBER BASE WALLS: GYPSUM BOARD (GB) CEILING: ACT OR GB (MIN. 9'-0" AFF) Drawing Title: COMMERCIAL VEHICLE INSPECITON AND GATEHOUSE (LOW VOLUME) 1/6/2015 8:57:53 AM A COMMERCIAL VEHICLE INSPECTION AND GATEHOUSE LOW VOLUME (NOTIONAL MASSING) Date: 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-112 1 2 3 4 5 NOTES NOT FOR CONSTRUCTION OUTBOUND LANES CONTAINMENT BARRIER BARRIER SIGNAL FINAL DENIAL BARRIER MAX CLEAR 5' - 0" ALTERNATE OVERWATCH LOCATION C INDUCTION LOOPS INBOUND LANES CRASH ATTENUATOR SF VEHICLE BARRIER SIGNAL BARRIER CONTROL ACTIVATION B 7' - 0" CONTAINMENT BARRIER OVERWATCH UP 6' - 0" MIN STOP LINE BARRIER CONTROLS 7' - 0" 165' INTERIOR FINISHES BOOTH FLOOR: FINISHED CONCRETE OR VCT BASE: RUBBER BASE WALLS: DURABLE GYPSUM BOARD (GB) WITH PROTECTIVE LINER PANEL CEILING: ACT OR GB (MIN. 8'-0" AFF) ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) D HVAC: A PACKED TERMINAL AIR CONDITIONER (PTAC) OR DUCTLESS SPLIT-SYSTEM WOULD BE USED. 2. PROVIDE BALLISTIC PROTECTION EQUIVALENT TO UL 752 LEVEL III AT EXTERIOR ENVELOPE (WINDOWS, DOORS, WALLS AND OTHER EQUIPMENT). 3. PROVIDE DATA CONNECTION AND TELEPHONE AT COUNTER. 4. PROVIDE BARRIER CONTROL ACTIVATION AT COUNTER. 5. PROVIDE A MINIMUM OF 360-DEGREE VISIBILITY AND A DIRECT LINE OF SIGHT TO THE ACCESS CONTROL ZONE OF THE ACP INCLUDING IDENTIFICATION AND INSPECTION AREAS. 6. PROVIDE WINDOWS THAT DO NOT INTERFERE WITH THE CAPABILITY TO RESPOND TO AN ATTACK. THEREFORE WINDOWS WILL BE CAPABLE OF BEING FULLY OPENED/REMOVED QUICKLY OR HAVE A SUBSTANTIAL GUN PORT TO ENABLE UNOBSTRUCTED LINE OF FIRE FROM THE POSITION. 7. ELEVATE THE FACILITY A MIN OF 3' TO AID THE OBSERVATION OF INCOMING TRAFFIC AND REDUCE INCIDENTAL/COLLATERAL DAMAGE BY CREATING A PLUNGING FIRE SCENARIO. 8. PROVIDE AN ANNUNCIATOR IN THE OVERWATCH TO ALERT SECURITY PERSONNEL OF THE DURESS ALARM BEING TRIGGERED AT THE OTHER GUARD FACILITIES. 9. 165' BETWEEN THE OVERWATCH AND THE FINAL DENIAL CAPABILITIES IS REQUIRED. 10. ECF/IACP AND BARRIERS SHALL COMPLY WITH UFGS 34 71 13.19 "ACTIVE VEHICLE BARRIERS" AND UFGS 34 41 26.00 10 "ACP CONTROL SYSTEMS" 11. NO EXPOSED CONDUIT OR WIRING IN OVERWATCH AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 1. HANDRAIL (BOTH SIDES) Drawing Title: OVERWATCH 1/6/2015 8:58:03 AM A OVERWATCH 0 4' 8' SCALE: 3/32 " = 1' Date: 16' SQUARE FOOTAGE (REFERENCE PROGRAM) MODULE = 49 GSF 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-113 1 2 3 4 5 NOT FOR CONSTRUCTION C B ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: D Drawing Title: OVERWATCH 1/6/2015 8:58:15 AM A OVERWATCH (NOTIONAL MASSING) Date: 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-114 3 4 5 NOTES 65' - 6" 31' - 0" 1. PERIMETER FENCE D AC CONDENSER BARRIER - OTHER DESIGNS ACCEPTABLE 4'-8" SCREEN WALL LINE OF ROOF OVERHANG (ABOVE) STAND-BY PORTABLE GENERATOR UNDER COUNTER REFRIGERATOR TR 4' - 0" MAX C 15' - 4" TOILET STOR & JAN TRANSACTION DRAWER (TYP) BREAK GATEHOUSE SECURITY BOLLARDS 43' - 0" 2' - 6" DBIDS TERMINAL / PRINTER EQUIPMENT CHARGING DUTY WEAPON STORAGE (ABOVE) ENTRY PLAZA BI-DIRECTIONAL TURNSTILES 26' - 8" ACCESSIBLE GATE B NOT FOR CONSTRUCTION LINE OF CANOPY ABOVE ATTACHED TO TURNSTILE CONSTRUCTION SUPPORT WALL THIS ENTRY CONDITION IS USED ONLY AS NEEDED AND NOT COMMON TO BASE ENTRY SEQUENCE. 2. THIS CONDITION IS NOT ILLUSTRATED IN SITE PLANS OR INCLUDED IN THE PROGRAM DOCUMENT. 3. WEAPONS STORAGE AND EQUIPMENT CHARGING STATIONS TO BE LOCATED ABOVE STORAGE CABINETS. 4. PROVIDE ACCESS TO NATIONAL CRIME INFORMATION CENTER (NCIC) AT EACH PROCESSING STATION. 5. PROVIDE UNDER COUNTER REFRIGERATOR, SINK AND MICROWAVE AT BREAK COUNTER. 6. HVAC: A PACKED TERMINAL AIR CONDITIONER (PTAC) OR DUCTLESS SPLIT-SYSTEM WOULD BE USED. 7. PROVIDE BALLISTIC PROTECTION EQUIVALENT TO UL 752 LEVEL III AT EXTERIOR ENVELOPE (WINDOWS, DOORS, WALLS AND OTHER EQUIPMENT). 8. ENTRANCES FOR COMMON ACCESS CARD (CAC) CREDENTIALED EMPLOYEES DOES NOT REQUIRE A MANNED FACILITY. 9. USE BI-DIRECTIONAL TURNSTILES TO ACCOMMODATE HEAVY PEDESTRIAN TRAFFIC IN THE MORNING AND EVENINGS. 10. QUANTITY OF TURNSTILES SHALL BE DETERMINED BY PEAK DEMAND (TYPICAL CAPACITY IS 15 USERS PER MINUTE IN ONE DIRECTION WITH ACCESS CONTROL). 11. ALL STANDARD COUNTERTOPS ARE 36" A.F.F. UNLESS NOTED OTHERWISE. INTERIOR FINISHES GATEHOUSE, STORAGE & BREAK FLOOR: SEALED / STAINED CONCRETE OR TILE BASE: RUBBER BASE WALLS: RIGID HIGH IMPACT WALL COVERING OVER HIGH IMPACT GYPSUM SHEATHING CEILING: ACT OR GB (MIN. 9'-0" AFF) TOILET FLOOR: BASE: WALLS: CEILING: PERIMETER FENCE TILE TILE BASE GYPSUM BOARD (GB) AND TILE WAINSCOT ACT OR GB (MIN. 9'-0" AFF) ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) 2 AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 1 Drawing Title: BARRIER - OTHER DESIGNS ACCEPTABLE PEDESTRIAN ENTRY A 1/6/2015 8:58:24 AM PEDESTRIAN ENTRY 0 4' 8' SCALE: 1/8 " = 1' 16' SQUARE FOOTAGE MODULE = 438 GSF HALF SCOPE = 196 GSF Date: 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-115 1 2 3 4 5 NOT FOR CONSTRUCTION C B ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: D Drawing Title: PEDESTRIAN ENTRY 1/6/2015 8:58:35 AM A PEDESTRIAN ENTRY (NOTIONAL MASSING) Date: 1 MARCH 2015 Designed By: AM Drawing No.: Drawn By:AM / KW Checked By: MDT A-116 1 3 2 4 5 GENERAL SITE PLAN NOTES: KEY NOTES: 1 MINIMUM STANDOFF DISTANCE SHALL BE DETERMINED PER UFC 2-100-01, UFC 4-010-02, AND SDDCTEA PAMPHLET 55-15. NOT FOR CONSTRUCTION 1. DESIGN ENTRY POINTS TO ALLOW ADEQUATE ASSESSMENT OF AUTHORIZATION OF APPROACHING VEHICLES, WHILE MAINTAINING SAFETY OF GATE GUARDS AND OTHER VEHICLES APPROACHING THE ENTRY POINT, WITHOUT DISRUPTING PEDESTRIAN OR VEHICULAR TRAFFIC FLOW. 2 MINIMUM TURNING RADIUS SHALL BE BASED ON ANTICIPATED LARGEST VEHICLE LIKELY TO USE THE FACILITY PER SDDCTEA PAMPHLET 55-15, AND UFC 4-022-01. 3 SIZING OF INSPECTION AREAS SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15. 2. LIMIT SPEED OF VEHICLES BY USING CURVILINEAR ACCESS ROADS, SPEED HUMPS OR TEXTURED PAVEMENTS. 4 VEHICLE INSPECTION CONSIDERATIONS SHALL BE IN ACCORDANCE WITH UFC 4-022-01 AND SDDCTEA PAMPHLET 55-15. 3. UTILIZE EXISTING NATURAL SITE FEATURES SUCH AS TOPOGRAPHY, WATER FEATURES, AND DENSE VEGETATION ALONG ROADWAY TO SECURE ENTRY AND EXIT PROCEDURES AND INCORPORATE NEW FEATURES WHERE APPROPRIATE.. 2705 Bee Cave Road, Suite 300, Austin, TX 78746 D 911 Central Parkway North, Suit 425, San Antonio, TX 78232 501 North Broadway, St. Louise, MO 63102 5 ACCESS CONTROL DEVICES, SUCH AS DROP ARM GATES, SHALL BE APPROVED BY BASE. 4. PROVIDE CLEAR SIGHT LINES WITHIN SITE TO ALLOW SECURITY PERSONNEL AND SECURITY DEVICES TO MONITOR THE SITE AND AREA BEYOND. 6 VEHICULAR CONTAINMENT BARRIER SHALL MEET THE REQUIREMENTS OF UFC 4-022-02 AND SDDCTEA PAMPHLET 55-15. 7 LANE TRANSITIONS SHALL BE ACHEIVED AT A 10:1 TAPER PER SDDCTEA PAMPHLET 55-15. 5. MINIMIZE CLEAR SIGHT LINES INTO SITE BY POTENTIAL AGGRESSORS THROUGH SCREENING OR UTILIZATION OF NATURAL FEATURES. 9 RESPONSE ZONE LENGTH SHALL BE CALCULATED ON UFC 4-022-01, UFC 4-022-02, SDDCTEA PAMPHLET 55-15, LATEST EDITIONS, BASED ON GOVERNING THREAT SCENARIO (INBOUND/HIGH SPEED, OUTBOUND/HIGHSPEED, OR ONE OF THE COVERT ATTACKS) WHICH RESULTS IN THE LONGEST REQUIRED ZONE LENGTH. APPROACH ZONE LENGTH, RESPONSE ZONE SPEED REDUCING MEASURES, AND WRONG-WAY AND OVERSPEED DETECTION MEANS WILL IMPACT THE RESULTING OVERALL ACCESS CONTROL POINTS LENGTH. REFER TO THE DESIGN CRITERIA FOR THREAT ROUTE CALCULATIONS OVERVIEW. 6. PROVIDE SELF-REJECTION LANE WITH TURNING RADII ADEQUATE FOR SEMI-TRUCKS PRIOR TO GATEHOUSE WHERE COMMERCIAL VEHICLES ARE PROHIBITED FROM ENTERING. 7. DESIGN PRIMARY VEHICLE INSPECTION AREAS SO THEY ARE NOT VISIBLE TO THE PUBLIC. 11 THE OVERWATCH POSITION, IF PROVIDED, SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15 AND UFC 4-022-01. THE OVERWATCH POSITION SHALL BE ELEVATED, REACTIVE TO ONCOMING TRAFFIC/THREAT, SO AS TO DIRECT ANY AMMUNITION FIRE TOWARD GROUND SHOULD TARGET BE MISSED. OVERWATCH SHALL ALSO BE LOCATED A SAFE DISTANCE FROM FINAL DENIAL SHOULD IT BE DEPLOYED AND A WRECK OCCUR. 9. INCORPORATE SITE LIGHTING WITH A MINIMUM AVERAGE OF 4 FOOT-CANDLES TO PROVIDE SECURITY PERSONNEL A CLEAR VIEW OF APPROACHING DRIVERS AND DRIVERS A CLEAR VIEW OF GATEHOUSE. 10. VISITOR'S CENTER SHALL BE LOCATED SO THAT IT IS EASILY ACCESSIBLE, CLEARLY VISIBLE AND HAS THE CAPACITY FOR VEHICLES TO SELF-REJECT WITH MINIMAL TRAFFIC DISRUPTION. 12 REVERSE ENTRY DEVICES SUCH AS DETECTION LOOPS, WHICH ARE THE PREFERRED METHOD, SHALL BE APPROVED BY BASE. IN ADDITION, SECURITY FORCES SHALL BE CONSULTED. 13 GATE NOT REQUIRED TO BE AT BASE PERIMETER. LOCATION TO BE BASE SPECIFIC. 14 VISITOR'S CENTER PARKING SHALL BE SIZED IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15. VISITOR/DoD ENTRY GATE (UNCONSTRAINED) SCHEMATIC APPROX. 2000' B POST & CABLE BARRIER, RETAINING WALL, OR OTHER APPROVED ROADWAY CONTAINMENT BARRIER 6 R.A.M. POST (AT HIGHER FPCONs) R182' ACCESS CONTROL (DROP ARM GATE) 5 R20 0' R25' R5' R5' 2 R25' R5' R21' R5' 45' R250' 14 4' VISITOR'S CENTER PEDESTRIAN SIDEWALK STANDOFF DISTANCE 1 2' A (2) 15' GATES 13 R5' 28 ' 82' ' R1 GATEHOUSE CANOPY 10 :1 TA ACCESS CONTROL PE R (DROP ARM GATE) 5 7 R25' R15' R15' R15' R200' 25' R5' 22' R25' R200' PORTABLE TRAFFIC CONTROL DEVICE STORAGE 0 22' R25' R25' 4 3 POV INSPECTION R5' 40' 30' R15' R25' 25' 10:1 TAPER 60' 120' SCALE: 1 " = 60' 22' R25' R25' R35' REVERSE ENTRY DEVICE (TYP. SYM.) 12 66' 82' REJECTION LANE REJECTION LANE R5' 28' R1 R35' R5' VISITOR'S PARKING 14 20' (2) 15' GATES 13 FINAL DENIAL CAPABILITY 10 ALTERNATE POV INSPECTION AREA CHASE VEHICLE CHASE VEHICLE R5' APPROX. 365' SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL SIZE 22X34 SHEET SELF REJECTION LANE (ABLE TO ACCOMMODATE SEMI TRUCKS) AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 8. PROVIDE A FINAL DENIAL SYSTEM THAT WILL PROHIBIT UNAUTHORIZED VEHICLES FROM ENTERING THE SITE, BOTH ON THE INBOUND AND OUTBOUND SIDE. 10 FINAL DENIAL CAPABILITIES SHALL MEET THE REQUIREMENTS OF UFC 4-022-01, UFC 4-022-02, UFGS 34 71 13.19, UFGS 34 41 26.00, AND SDDCTEA PAMPHLET 55-15. C ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) 8 NUMBER OF ID CHECK STATIONS SHALL BE BASED ON TRAFFIC ENGINEERING ASSESSMENT, PER SDDCTEA PAMPHLET 55-15. Jacobs Project No.: FDWD5022 Drawing Title: 7 VISITOR/DoD ENTRY GATE UNCONSTRAINED R182' SECURITY FORCES PARKING R.A.M. POST (AT HIGHER FPCONs) RESPONSE ZONE 9 ID CHECK BOOTH 8 PORTABLE TRAFFIC CONTROL DEVICE STORAGE PORTABLE TRAFFIC CONTROL DEVICE OVERWATCH 11 CHASE VEHICLE Date: 1 MARCH 2015 Designed By: SM Drawn By: LW Checked By: MT Drawing No.: A-201 1 3 2 4 GENERAL SITE PLAN NOTES: KEY NOTES: 1 MINIMUM STANDOFF DISTANCE SHALL BE DETERMINED PER UFC 2-100-01, UFC 4-010-02, AND SDDCTEA PAMPHLET 55-15. 10 FINAL DENIAL CAPABILITIES SHALL MEET THE REQUIREMENTS OF UFC 4-022-01, UFC 4-022-02, UFGS 34 71 13.19, UFGS 34 41 26.00, AND SDDCTEA PAMPHLET 55-15. 2 MINIMUM TURNING RADIUS SHALL BE BASED ON ANTICIPATED LARGEST VEHICLE LIKELY TO USE THE FACILITY PER SDDCTEA PAMPHLET 55-15, AND UFC 4-022-01. 3 SIZING OF INSPECTION AREAS SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15. 11 THE OVERWATCH POSITION, IF PROVIDED, SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15 AND UFC 4-022-01. THE OVERWATCH POSITION SHALL BE ELEVATED, REACTIVE TO ONCOMING TRAFFIC/THREAT, SO AS TO DIRECT ANY AMMUNITION FIRE TOWARD GROUND SHOULD TARGET BE MISSED. OVERWATCH SHALL ALSO BE LOCATED A SAFE DISTANCE FROM FINAL DENIAL SHOULD IT BE DEPLOYED AND A WRECK OCCUR. 4 VEHICLE INSPECTION CONSIDERATIONS SHALL BE IN ACCORDANCE WITH UFC 4-022-01 AND SDDCTEA PAMPHLET 55-15. 5 ACCESS CONTROL DEVICES, SUCH AS DROP ARM GATES, SHALL BE APPROVED BY BASE. 6 VEHICULAR CONTAINMENT BARRIER SHALL MEET THE REQUIREMENTS OF UFC 4-022-02 AND SDDCTEA PAMPHLET 55-15. NUMBER OF ID CHECK STATIONS SHALL BE BASED ON TRAFFIC ENGINEERING ASSESSMENT, PER SDDCTEA PAMPHLET 55-15. 9 RESPONSE ZONE LENGTH SHALL BE CALCULATED ON UFC 4-022-01, UFC 4-022-02, SDDCTEA PAMPHLET 55-15, LATEST EDITIONS, BASED ON GOVERNING THREAT SCENARIO (INBOUND/HIGH SPEED, OUTBOUND/HIGHSPEED, OR ONE OF THE COVERT ATTACKS) WHICH RESULTS IN THE LONGEST REQUIRED ZONE LENGTH. APPROACH ZONE LENGTH,RESPONSE ZONE SPEED REDUCING MEASURES, AND WRONG-WAY AND OVERSPEED DETECTION MEANS WILL IMPACT THE RESULTING OVERALL ACCESS CONTROL POINTS LENGTH. REFER TO THE DESIGN CRITERIA FOR THREAT ROUTE CALCULATIONS OVERVIEW. 3. REFERENCE NOTES 3 THROUGH 10 ON SHEET 201. 2705 Bee Cave Road, Suite 300, Austin, TX 78746 911 Central Parkway North, Suit 425, San Antonio, TX 78232 501 North Broadway, St. Louise, MO 63102 13 GATE NOT REQUIRED TO BE AT BASE PERIMETER. LOCATION TO BE BASE SPECIFIC. 14 VISITOR'S CENTER PARKING SHALL BE SIZED IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15. RE REVERSE ENTRY DEVICE (TYP. SYM.) 12 ON SP ' 25 22' O N E A L O NG C L EN SE Z TR 1T AP RD 9 ER 7 R195' 40 ' 10: Y ' 25' R5 R1 R.A.M. POST (AT HIGHER FPCONs) 5' R13 3 0' ALT. POV INSPECTION VISITOR/DoD ENTRY GATE (CONSTRAINED) SCHEMATIC CHASE VEHICLE GATEHOUSE 28' 64' R5' 20' ACCESS CONTROL (DROP ARM GATE) 5 SELF REJECTION LANE (ABLE TO ACCOMMODATE SEMI TRUCKS) ID CHECK BOOTH 8 (4) 15' GATES 13 CANOPY RETURN LANE 5' ' 00 R1 FINAL DENIAL CAPABILITY 10 R5' ' R3 R5 10:1 TAPER 7 24 R50' R6 ' R15 ' R7 0' R1 2 VISITOR'S CENTER R1 5' R5' 3 8' R2 CHASE VEHICLE 10:1 TAPER 7 35 R5 ' ' 25' R 5' 5' 5' R1 POV INSPECTION 4 OVERWATCH 11 PORTABLE TRAFFIC CONTROL DEVICE STORAGE 3 R1 25 R1 ' 5 R2 PORTABLE TRAFFIC CONTROL DEVICE 5' ' R12'-6" R5 VISITOR'S PARKING 14 R1 R145' 50' 100' SCALE: 1 " = 50' Jacobs Project No.: FDWD5022 10:1 TAPER 7 Drawing Title: INSPECTION LANE CHASE VEHICLE VISITOR/DoD ENTRY GATE CONSTRAINED R.A.M. POST (AT HIGHER FPCONs) ACCESS CONTROL (DROP ARM GATE) 5 STANDOFF DISTANCE 1 25' 5' ' A 0 PORTABLE TRAFFIC CONTROL DEVICE STORAGE ' R25 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL SIZE 22X34 SHEET APPROX. 700' ACCESS CONTROL (DROP ARM GATE) 5 B NOT FOR CONSTRUCTION ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) LANE TRANSITIONS SHALL BE ACHEIVED AT A 10:1 TAPER PER SDDCTEA PAMPHLET 55-15. 8 REJECTION LANE 2. IN CONFINED SITES, INCORPORATE A CURVILINEAR ACCESS ROAD, TRAFFIC CIRCLES AND/OR SMALL RADIUS TURNS IN ORDER TO LIMIT THE SPEED OF VEHICLES AND CREATE THE OPPORTUNITY FOR A MORE INTERESTING APPROACH. 12 REVERSE ENTRY DEVICES SUCH AS DETECTION LOOPS, WHICH ARE THE PREFERRED METHOD, SHALL BE APPROVED BY BASE. IN ADDITION, SECURITY FORCES SHALL BE CONSULTED. 7 C 1. REFERENCE NOTE 1 ON SHEET 201. AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: D 5 POST & CABLE BARRIER, RETAINING WALL, OR OTHER APPROVED ROADWAY CONTAINMENT BARRIER 6 APPROX. 1000' Date: 1 MARCH 2015 Designed By: SM Drawn By: LW Checked By: MT Drawing No.: A-202 1 3 2 4 5 GENERAL SITE PLAN NOTES: KEY NOTES: 1. DESIGN ENTRY POINTS TO ALLOW ADEQUATE ASSESSMENT OF AUTHORIZATION OF APPROACHING VEHICLES, WHILE MAINTAINING SAFETY OF GATE GUARDS AND OTHER VEHICLES APPROACHING THE ENTRY POINT, WITHOUT DISRUPTING PEDESTRIAN OR VEHICULAR TRAFFIC FLOW. 1 MINIMUM STANDOFF DISTANCE SHALL BE DETERMINED PER UFC 2-100-01, UFC 4-010-02, AND SDDCTEA PAMPHLET 55-15. 2 MINIMUM TURNING RADIUS SHALL BE BASED ON ANTICIPATED LARGEST VEHICLE LIKELY TO USE THE FACILITY PER SDDCTEA PAMPHLET 55-15, AND UFC 4-022-01. 2. LIMIT SPEED OF VEHICLES BY USING CURVILINEAR ACCESS ROADS, SPEED HUMPS OR TEXTURED PAVEMENTS. 3 SIZING OF INSPECTION AREAS SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15. 2705 Bee Cave Road, Suite 300, Austin, TX 78746 4 VEHICLE INSPECTION CONSIDERATIONS SHALL BE IN ACCORDANCE WITH UFC 4-022-01 AND SDDCTEA PAMPHLET 55-15. 3. UTILIZE EXISTING NATURAL SITE FEATURES SUCH AS TOPOGRAPHY, WATER FEATURES, AND DENSE VEGETATION ALONG ROADWAY TO SECURE ENTRY AND EXIT PROCEDURES AND INCORPORATE NEW FEATURES WHERE APPROPRIATE. 5 ACCESS CONTROL DEVICES, SUCH AS DROP ARM GATES, SHALL BE APPROVED BY BASE. 911 Central Parkway North, Suit 425, San Antonio, TX 78232 501 North Broadway, St. Louise, MO 63102 6 VEHICULAR CONTAINMENT BARRIER SHALL MEET THE REQUIREMENTS OF UFC 4-022-02 AND SDDCTEA PAMPHLET 55-15. 4. PROVIDE CLEAR SIGHT LINES WITHIN SITE TO ALLOW SECURITY PERSONNEL AND SECURITY DEVICES TO MONITOR THE SITE AND AREA BEYOND. 7 LANE TRANSITIONS SHALL BE ACHEIVED AT A 10:1 TAPER PER SDDCTEA PAMPHLET 55-15. 5. MINIMIZE CLEAR SIGHT LINES INTO SITE BY POTENTIAL AGGRESSORS THROUGH SCREENING OR UTILIZATION OF NATURAL FEATURES. 8 NUMBER OF ID CHECK STATIONS SHALL BE BASED ON TRAFFIC ENGINEERING ASSESSMENT, PER SDDCTEA PAMPHLET 55-15. 9 RESPONSE ZONE LENGTH SHALL BE CALCULATED ON UFC 4-022-01, UFC 4-022-02, SDDCTEA PAMPHLET 55-15, LATEST EDITIONS, BASED ON GOVERNING THREAT SCENARIO (INBOUND/HIGH SPEED, OUTBOUND/HIGHSPEED, OR ONE OF THE COVERT ATTACKS) WHICH RESULTS IN THE LONGEST REQUIRED ZONE LENGTH. APPROACH ZONE LENGTH, RESPONSE ZONE SPEED REDUCING MEASURES, AND WRONG-WAY AND OVERSPEED DETECTION MEANS WILL IMPACT THE RESULTING OVERALL ACCESS CONTROL POINTS LENGTH. REFER TO THE DESIGN CRITERIA FOR THREAT ROUTE CALCULATIONS OVERVIEW. ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) D NOT FOR CONSTRUCTION 6. PROVIDE SELF-REJECTION LANE WITH TURNING RADII ADEQUATE FOR SEMI-TRUCKS PRIOR TO GATEHOUSE WHERE COMMERCIAL VEHICLES ARE PROHIBITED FROM ENTERING. 7. DESIGN PRIMARY VEHICLE INSPECTION AREAS SO THEY ARE NOT VISIBLE TO THE PUBLIC. 10 FINAL DENIAL CAPABILITIES SHALL MEET THE REQUIREMENTS OF UFC 4-022-01, UFC 4-022-02, UFGS 34 71 13.19, UFGS 34 41 26.00, AND SDDCTEA PAMPHLET 55-15 . 9. INCORPORATE SITE LIGHTING WITH A MINIMUM AVERAGE OF 4 FOOT-CANDLES TO PROVIDE SECURITY PERSONNEL A CLEAR VIEW OF APPROACHING DRIVERS AND DRIVERS A CLEAR VIEW OF GATEHOUSE. 12 REVERSE ENTRY DEVICES SUCH AS DETECTION LOOPS, WHICH ARE THE PREFERRED METHOD, SHALL BE APPROVED BY BASE. IN ADDITION, SECURITY FORCES SHALL BE CONSULTED. 13 GATE NOT REQUIRED TO BE AT BASE PERIMETER. LOCATION TO BE BASE SPECIFIC. C DoD PERSONNEL GATE (UNCONSTRAINED) SCHEMATIC APPROX. 1975' RETURN LANE/SELF-REJECTION LANE CHASE VEHICLE B R.A.M. POST (AT HIGHER FPCONs) REJECTION LANE SELF REJECTION LANE (ABLE TO ACCOMMODATE SEMI TRUCKS) EXIT LANE ALTERNATE POV INSPECTION AREA POST & CABLE BARRIER, OR RETAINING WALL, OR OTHER APPROVED ROADWAY CONTAINMENT BARRIER 6 ACCESS CONTROL (DROP ARM GATE) 5 14' POV 4 INSPECTION R25' R98' R235' R25' R R25' R25' R21' 13 (2) 15' GATES 10:1 TAP ER 14' 4' 60' 120' SCALE: 1 " = 60' Jacobs Project No.: 40' FDWD5022 25' Drawing Title: 7 R25' DoD PERSONNEL ENTRY GATE UNCONSTRAINED ID CHECK BOOTH 8 RESPONSE ZONE 9 CANOPY 2' 30' R5' 28' R170' PEDESTRIAN SIDEWALK STANDOFF DISTANCE 1 25' 0' R37 R5' R155' R.A.M. POST (AT HIGHER FPCONs) R15' R5' 45' ACCESS CONTROL (DROP ARM GATE) 5 R35' 5' 0 GATEHOUSE R5' 14' 22' R5' 4' R25' 4' R25' 2 R20 0' R 7 30' 3 R5' R5' 14' 20' R25' 10:1 TAPE 42' 00' R2 REJECTION LANE REVERSE ENTRY DEVICE (TYP. SYM.) 12 R25' R35' A CHASE VEHICLE FINAL DENIAL CAPABILITY 10 (2) 15' GATES 13 APPROX. 310' SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL SIZE 22X34 SHEET AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 8. PROVIDE A FINAL DENIAL SYSTEM THAT WILL PROHIBIT UNAUTHORIZED VEHICLES FROM ENTERING THE SITE, BOTH ON THE INBOUND AND OUTBOUND SIDE. 11 THE OVERWATCH POSITION, IF PROVIDED, SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15 AND UFC 4-022-01. THE OVERWATCH POSITION SHALL BE ELEVATED, REACTIVE TO ONCOMING TRAFFIC/THREAT, SO AS TO DIRECT ANY AMMUNITION FIRE TOWARD GROUND SHOULD TARGET BE MISSED. OVERWATCH SHALL ALSO BE LOCATED A SAFE DISTANCE FROM FINAL DENIAL SHOULD IT BE DEPLOYED AND A WRECK OCCUR. OVERWATCH 11 CHASE VEHICLE 1 MARCH 2015 PORTABLE TRAFFIC CONTROL DEVICE STORAGE Date: PORTABLE TRAFFIC CONTROL DEVICE Designed By: SM Drawn By: LW Checked By: MT PORTABLE TRAFFIC CONTROL DEVICE STORAGE Drawing No.: A-203 1 3 2 4 KEY NOTES: 5 GENERAL SITE PLAN NOTES: 1 MINIMUM STANDOFF DISTANCE SHALL BE DETERMINED PER UFC 2-100-01, UFC 4-010-02, AND SDDCTEA PAMPHLET 55-15. 1. REFERENCE NOTE 1 ON SHEET 203. 2 MINIMUM TURNING RADIUS SHALL BE BASED ON ANTICIPATED LARGEST VEHICLE LIKELY TO USE THE FACILITY PER SDDCTEA PAMPHLET 55-15, AND UFC 4-022-01. 3 SIZING OF INSPECTION AREAS SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15. 2. IN CONFINED SITES, INCORPORATE A CURVILINEAR ACCESS ROAD, TRAFFIC CIRCLES AND/OR SMALL RADIUS TURNS IN ORDER TO LIMIT THE SPEED OF VEHICLES AND CREATE THE OPPORTUNITY FOR A MORE INTERESTING APPROACH. 4 VEHICLE INSPECTION CONSIDERATIONS SHALL BE IN ACCORDANCE WITH UFC 4-022-01 AND SDDCTEA PAMPHLET 55-15. 3. REFERENCE NOTES 3 THROUGH 9 ON SHEET 203. NOT FOR CONSTRUCTION 2705 Bee Cave Road, Suite 300, Austin, TX 78746 911 Central Parkway North, Suit 425, San Antonio, TX 78232 D 4. IF THE DISTANCE BETWEEN THE PUBLIC ROADWAY AND INTERNAL BASE ROADWAY IS LESS THAN 1000', REFERENCE THE ALTERNATE DoD CONSTRAINED SITE ON SHEET A-204A. 5 ACCESS CONTROL DEVICES, SUCH AS DROP ARM GATES, SHALL BE APPROVED BY BASE. 501 North Broadway, St. Louise, MO 63102 6 VEHICULAR CONTAINMENT BARRIER SHALL MEET THE REQUIREMENTS OF UFC 4-022-02 AND SDDCTEA PAMPHLET 55-15. 7 LANE TRANSITIONS SHALL BE ACHEIVED AT A 10:1 TAPER PER SDDCTEA PAMPHLET 55-15. ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) 8 NUMBER OF ID CHECK STATIONS SHALL BE BASED ON TRAFFIC ENGINEERING ASSESSMENT, PER SDDCTEA PAMPHLET 55-15. 9 RESPONSE ZONE LENGTH SHALL BE CALCULATED ON UFC 4-022-01, UFC 4-022-02, SDDCTEA PAMPHLET 55-15, LATEST EDITIONS, BASED ON GOVERNING THREAT SCENARIO (INBOUND/HIGH SPEED, OUTBOUND/HIGHSPEED, OR ONE OF THE COVERT ATTACKS) WHICH RESULTS IN THE LONGEST REQUIRED ZONE LENGTH. APPROACH ZONE LENGTH, RESPONSE ZONE SPEED REDUCING MEASURES, AND WRONG-WAY AND OVERSPEED DETECTION MEANS WILL IMPACT THE RESULTING OVERALL ACCESS CONTROL POINTS LENGTH. REFER TO THE DESIGN CRITERIA FOR THREAT ROUTE CALCULATIONS OVERVIEW. 11 THE OVERWATCH POSITION, IF PROVIDED, SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15 AND UFC 4-022-01. THE OVERWATCH POSITION SHALL BE ELEVATED, REACTIVE TO ONCOMING TRAFFIC/THREAT, SO AS TO DIRECT ANY AMMUNITION FIRE TOWARD GROUND SHOULD TARGET BE MISSED. OVERWATCH SHALL ALSO BE LOCATED A SAFE DISTANCE FROM FINAL DENIAL SHOULD IT BE DEPLOYED AND A WRECK OCCUR. 12 REVERSE ENTRY DEVICES SUCH AS DETECTION LOOPS, WHICH ARE THE PREFERRED METHOD, SHALL BE APPROVED BY BASE. IN ADDITION, SECURITY FORCES SHALL BE CONSULTED. 13 GATE NOT REQUIRED TO BE AT BASE PERIMETER. LOCATION TO BE BASE SPECIFIC. REVERSE ENTRY DEVICE (TYP. SYM.) 12 RE C ON SP O N E A L O NG C SE Z L EN TR Y RD 9 REJECTION LANE R190' R.A.M. POST (AT HIGHER FPCONs) CHASE VEHICLE DoD GATEHOUSE 25' 22' 40' ACCESS CONTROL (DROP ARM GATE) 5 R5' 25' R1 R15' ' ALT. POV INSPECTION 3 20' 14' 30 SELF REJECTION LANE (ABLE TO ACCOMMODATE SEMI TRUCKS) ACCESS CONTROL (DROP ARM GATE) 5 30' DoD PERSONNEL GATE (CONSTRAINED) SCHEMATIC ID CHECK BOOTH 8 CANOPY 10:1 TAPER 7 RETURN LANE ' 00 R1 R35' R5' R5 R5' ' R5' R50' 24 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL SIZE 22X34 SHEET B APPROX. 560' (4) 15' GATES 13 AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 10 FINAL DENIAL CAPABILITIES SHALL MEET THE REQUIREMENTS OF UFC 4-022-01, UFC 4-022-02, UFGS 34 71 13.19, UFGS 34 41 26.00, AND SDDCTEA PAMPHLET 55-15. R6 2 R35' R7 0' 5' FINAL DENIAL CAPABILITY 10 R25' CHASE VEHICLE POV INSPECTION 4 R138' R138 138 13 38 8' 8' PORTABLE TRAFFIC CONTROL DEVICE STORAGE 3 OVERWATCH 11 R1 25 R15' ' R25' PORTABLE TRAFFIC CONTROL DEVICE R50' PORTABLE TRAFFIC CONTROL DEVICE STORAGE R15' 0 50' 100' SCALE: 1 " = 50' Jacobs Project No.: 10:1 TAPER 7 R25' INSPECTION LANE A CHASE VEHICLE DoD PERSONNEL ENTRY GATE CONSTRAINED R.A.M. POST (AT HIGHER FPCONs) POST & CABLE BARRIER, RETAINING WALL, OR OTHER APPROVED ROADWAY CONTAINMENT BARRIER 6 APPROX. 1000' FDWD5022 Drawing Title: ACCESS CONTROL (DROP ARM GATE) 5 R145' STANDOFF DISTANCE 1 25' Date: 1 MARCH 2015 Designed By: SM Drawn By: LW Checked By: MT Drawing No.: A-204 1 3 2 4 KEY NOTES: 5 GENERAL SITE PLAN NOTES: 1 MINIMUM STANDOFF DISTANCE SHALL BE DETERMINED PER UFC 2-100-01, UFC 4-010-02, AND SDDCTEA PAMPHLET 55-15. 1. REFERENCE NOTE 1 ON SHEET 203. 2 MINIMUM TURNING RADIUS SHALL BE BASED ON ANTICIPATED LARGEST VEHICLE LIKELY TO USE THE FACILITY TRAVELING AT 15 MPH PER SDDCTEA PAMPHLET 55-15, AND UFC 4-022-01. 2. IN CONFINED SITES, INCORPORATE A CURVILINEAR ACCESS ROAD, TRAFFIC CIRCLES AND/OR SMALL RADIUS TURNS IN ORDER TO LIMIT THE SPEED OF VEHICLES AND CREATE THE OPPORTUNITY FOR A MORE INTERESTING APPROACH. 3 SIZING OF INSPECTION AREAS SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15 3. REFERENCE NOTES 3 THROUGH 9 ON SHEET 203. NOT FOR CONSTRUCTION 2705 Bee Cave Road, Suite 300, Austin, TX 78746 911 Central Parkway North, Suit 425, San Antonio, TX 78232 4 VEHICLE INSPECTION CONSIDERATIONS SHALL BE IN ACCORDANCE WITH UFC 4-022-01 AND SDDCTEA PAMPHLET 55-15. 501 North Broadway, St. Louise, MO 63102 D 5 ACCESS CONTROL DEVICES, SUCH AS DROP ARM GATES, SHALL BE APPROVED BY BASE. 6 VEHICULAR CONTAINMENT BARRIER SHALL MEET THE REQUIREMENTS OF UFC 4-022-02 AND SDDCTEA PAMPHLET 55-15. ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) 7 LANE TRANSITIONS SHALL BE ACHEIVED AT A 10:1 TAPER PER SDDCTEA PAMPHLET 55-15. 8 NUMBER OF ID CHECK STATIONS SHALL BE BASED ON TRAFFIC ENGINEERING ASSESSMENT, PER SDDCTEA PAMPHLET 55-15. 9 RESPONSE ZONE LENGTH SHALL BE CALCULATED ON UFC 4-022-01, UFC 4-022-02, SDDCTEA PAMPHLET 55-15, LATEST EDITIONS, BASED ON GOVERNING THREAT SCENARIO (INBOUND/HIGH SPEED, OUTBOUND/HIGHSPEED, OR ONE OF THE COVERT ATTACKS) WHICH RESULTS IN THE LONGEST REQUIRED ZONE LENGTH. APPROACH ZONE LENGTH, RESPONSE ZONE SPEED REDUCING MEASURES, AND WRONG-WAY AND OVERSPEED DETECTION MEANS WILL IMPACT THE RESULTING OVERALL ACCESS CONTROL POINTS LENGTH. REFER TO THE DESIGN CRITERIA FOR THREAT ROUTE CALCULATIONS OVERVIEW. 1 6 10 FINAL DENIAL CAPABILITIES SHALL MEET THE REQUIREMENTS OF UFC 4-022-01, UFC 4-022-02, UFGS 34 71 13.19, UFGS 34 41 26.00, AND SDDCTEA PAMPHLET 55-15. 11 THE OVERWATCH POSITION, IF PROVIDED, SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15 AND UFC 4-022-01. THE OVERWATCH POSITION SHALL BE ELEVATED, REACTIVE TO ONCOMING TRAFFIC/THREAT, SO AS TO DIRECT ANY AMMUNITION FIRE TOWARD GROUND SHOULD TARGET BE MISSED. OVERWATCH SHALL ALSO BE LOCATED A SAFE DISTANCE FROM FINAL DENIAL SHOULD IT BE DEPLOYED AND A WRECK OCCUR. 12 REVERSE ENTRY DEVICES SUCH AS DETECTION LOOPS, WHICH ARE THE PREFERRED METHOD, SHALL BE APPROVED BY BASE. IN ADDITION, SECURITY FORCES SHALL BE CONSULTED. 13 GATE NOT REQUIRED TO BE AT BASE PERIMETER. LOCATION TO BE BASE SPECIFIC. C 4 APPROX 650 LF 3 12 8 10 B SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL SIZE 22X34 SHEET 12 AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 2 9 7 11 5 12 3 4 5 13 7 SCALE: NOT TO SCALE Jacobs Project No.: FDWD5022 Drawing Title: A DoD PERSONNEL ENTRY GATE ALTERNATE CONSTRAINED APPROX. 600 LF DoD PERSONNEL GATE (CONSTRAINED) ALTERNATE SCHEMATIC Date: 1 MARCH 2015 Designed By: SM Drawn By: LW Checked By: MT Drawing No.: A-204A 1 3 2 KEY NOTES: 5 GENERAL SITE PLAN NOTES: 1 MINIMUM STANDOFF DISTANCE SHALL BE DETERMINED PER UFC 2-100-01, UFC 4-010-02, AND SDDCTEA PAMPHLET 55-15. 1. DESIGN ENTRY POINTS TO ALLOW ADEQUATE ASSESSMENT OF AUTHORIZATION OF APPROACHING VEHICLES, WHILE MAINTAINING SAFETY OF GATE GUARDS AND OTHER VEHICLES APPROACHING THE ENTRY POINT, WITHOUT DISRUPTING PEDESTRIAN OR VEHICULAR TRAFFIC FLOW. 2 MINIMUM TURNING RADIUS SHALL BE BASED ON ANTICIPATED LARGEST VEHICLE LIKELY TO USE THE FACILITY PER SDDCTEA PAMPHLET 55-15, AND UFC 4-022-01. 2. LIMIT SPEED OF VEHICLES BY USING CURVILINEAR ACCESS ROADS, SPEED HUMPS OR TEXTURED PAVEMENT. 3 SIZING OF INSPECTION AREAS SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15. 3. UTILIZE EXISTING NATURAL SITE FEATURES SUCH AS TOPOGRAPHY, WATER FEATURES, AND DENSE VEGETATION ALONG ROADWAY TO SECURE ENTRY AND EXIT PROCEDURES AND INCORPORATE NEW FEATURES WHERE APPROPRIATE. NOT FOR CONSTRUCTION 2705 Bee Cave Road, Suite 300, Austin, TX 78746 911 Central Parkway North, Suit 425, San Antonio, TX 78232 4 TRUCK INSPECTION CONSIDERATIONS SHALL BE IN ACCORDANCE WITH UFC 4-022-01 AND SDDCTEA PAMPHLET 55-15. 5 ACCESS CONTROL DEVICES, SUCH AS DROP ARM GATES, SHALL BE APPROVED BY BASE. 6 VEHICULAR CONTAINMENT BARRIER SHALL MEET THE REQUIREMENTS OF UFC 4-022-02 AND SDDCTEA PAMPHLET 55-15. 7 LANE TRANSITIONS SHALL BE ACHIEVED AT A 10:1 TAPER PER SDDCTEA PAMPHLET 55-15. 8 TRUCK HOLDING SHALL BE BASED ON TRAFFIC ENGINEERING ASSESSMENT, PER SDDCTEA PAMPHLET 55-15. 9 RESPONSE ZONE IS NOT APPLICABLE AT COMMERCIAL GATES. THE FINAL DENIAL BARRIER SHALL REMAIN IN THE NORMALLY CLOSED MODE. 8. PROVIDE A FINAL DENIAL SYSTEM THAT WILL PROHIBIT UNAUTHORIZED VEHICLES FROM ENTERING THE SITE, BOTH ON THE INBOUND AND OUTBOUND SIDE. ACTIVE VEHICLE BARRIERS FOR COMMERCIAL ENTRIES ARE TO BE FUNCTION AT “NORMALLY CLOSED MODE”-GUARD OPENS AND CLOSES AVB FOR EACH VEHICLE ENTERING THE INSTALLATION. 10 FINAL DENIAL CAPABILITIES SHALL MEET THE REQUIREMENTS OF UFC 4-022-01, UFC 4-022-02, UFGS 34 71 13.19, UFGS 34 41 26.00, AND SDDCTEA PAMPHLET 55-15. FINAL DENIAL BARRIER SHALL REMAIN IN THE NORMALLY CLOSED MODE THEREFORE SHALL BE SELECTED WITH THE UNDERSTANDING OF THE FREQUENT USE. 9. INCORPORATE SITE LIGHTING WITH A MINIMUM AVERAGE OF 4 FOOT-CANDLES TO PROVIDE SECURITY PERSONNEL A CLEAR VIEW OF APPROACHING DRIVERS AND DRIVERS A CLEAR VIEW OF GATEHOUSE. 11 THE OVERWATCH POSITION, IF PROVIDED, SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 5-15 AND UFC 4-022-01. THE OVERWATCH POSITION SHALL BE ELEVATED, REACTIVE TO ONCOMING TRAFFIC/THREAT, SO AS TO DIRECT ANY AMMUNITION FIRE TOWARD GROUND SHOULD TARGET BE MISSED. OVERWATCH SHALL ALSO BE LOCATED A SAFE DISTANCE FROM FINAL DENIAL SHOULD IT BE DEPLOYED AND A WRECK OCCUR. 12 REVERSE ENTRY DEVICES SUCH AS DETECTION LOOPS, WHICH ARE THE PREFERRED METHOD, SHALL BE APPROVED BY BASE. IN ADDITION, SECURITY FORCES SHALL BE CONSULTED. 13 GATE NOT REQUIRED TO BE AT BASE PERIMETER. LOCATION TO BE BASE SPECIFIC. 501 North Broadway, St. Louise, MO 63102 4. PROVIDE CLEAR SIGHT LINES WITHIN SITE TO ALLOW SECURITY PERSONNEL AND SECURITY DEVICES TO MONITOR THE SITE AND AREA BEYOND. 5. MINIMIZE CLEAR SIGHT LINES INTO SITE BY POTENTIAL AGGRESSORS THROUGH SCREENING OR UTILIZATION OF NATURAL FEATURES. 6. PROVIDE ADEQUATE EXITING AND SELF-REJECTION LANES WITH TURNING RADII APPROPRIATE FOR SEMI-TRUCKS TO MINIMIZE TRAFFIC DISRUPTION. C COMMERCIAL GATE (UNCONSTRAINED) SCHEMATIC APPROX. 1350' (2) 12' GATES 13 SELF REJECTION LANE POST & CABLE BARRIER, RETAINING WALL, OR OTHER APPROVED ROADWAY CONTAINMENT BARRIER 6 EXIT LANE REVERSE ENTRY DEVICE (TYP. SYM.) 12 SECURITY FORCES & ESCORT PARKING REJECTION LANE FINAL DENIAL CAPABILITY 10 R35' 28' R35' 20' 15' R35' R27'-6" 74' 0 38'-0" R27'-6" 26' R27'-6" 16' 16' R35' TRUCK HOLDING 8 (9 TRUCK CAPACITY) 3 COMMERCIAL 4 INSPECTION & GATEHOUSE 18' X' 15' HEAVY DUTY PAVEMENT ISLAND TO BE INSTALLED ONLY IF X-RAY IS USED PER X-RAY MANUFACTURER RECOMMENDATIONS 40' 100' 9 Jacobs Project No.: FDWD5022 Drawing Title: COMMERCIAL ENTRY GATE UNCONSTRAINED ESCORT WAITING AREA (2 TRUCK CAPACITY) BYPASS LANE X-RAY TRUCK (OPTIONAL) 50' 7 (2) 12' GATES 13 STANDOFF DISTANCE 1 25' SCALE: 1 " = 50' 40'-0" ACCESS CONTROL (DROP ARM GATE) 5 38'-0" 2 X' A APPROX. 195' 20' 10' OVERWATCH 11 12' 20' SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL SIZE 22X34 SHEET B ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) 7. DESIGN PRIMARY VEHICLE INSPECTION AREAS SO THEY ARE NOT VISIBLE TO THE PUBLIC. AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: D 4 25' CHASE VEHICLE Date: 1 MARCH 2015 Designed By: SM Drawn By: LW Checked By: MT Drawing No.: A-205 3 2 4 KEY NOTES: GENERAL SITE PLAN NOTES: 1 MINIMUM STANDOFF DISTANCE SHALL BE DETERMINED PER UFC 2-100-01, UFC 4-010-02, AND SDDCTEA PAMPHLET 55-15. 1. REFERENCE NOTE 1 ON SHEET 205. 2 MINIMUM TURNING RADIUS SHALL BE BASED ON ANTICIPATED LARGEST VEHICLE LIKELY TO USE THE FACILITY PER SDDCTEA PAMPHLET 55-15, AND UFC 4-022-01. 3 SIZING OF INSPECTION AREAS SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15. 2. IN CONFINED SITES, INCORPORATE A CURVILINEAR ACCESS ROAD AND/OR SMALL RADIUS TURNS IN ORDER TO LIMIT THE SPEED OF VEHICLES AND CREATE THE OPPORTUNITY FOR A MORE INTERESTING APPROACH. 4 TRUCK INSPECTION CONSIDERATIONS SHALL BE IN ACCORDANCE WITH UFC 4-022-01 AND SDDCTEA PAMPHLET 55-15. 3. REFERENCE NOTES 3 THROUGH 9 SHEET 205. 5 ACCESS CONTROL DEVICES, SUCH AS DROP ARM GATES, SHALL BE APPROVED BY BASE. 6 VEHICULAR CONTAINMENT BARRIER SHALL MEET THE REQUIREMENTS OF UFC 4-022-02 AND SDDCTEA PAMPHLET 55-15. 7 LANE TRANSITIONS SHALL BE ACHEIVED AT A 10:1 TAPER PER SDDCTEA PAMPHLET 55-15. 8 TRUCK HOLDING SHALL BE BASED ON T.C.A., PER SDDCTEA PAMPHLET 55-15. 9 RESPONSE ZONE IS NOT APPLICABLE AT COMMERCIAL GATES. THE FINAL DENIAL BARRIER SHALL REMAIN IN THE NORMALLY CLOSED MODE. 10 NOT FOR CONSTRUCTION 2705 Bee Cave Road, Suite 300, Austin, TX 78746 911 Central Parkway North, Suit 425, San Antonio, TX 78232 501 North Broadway, St. Louise, MO 63102 FINAL DENIAL CAPABILITIES SHALL MEET THE REQUIREMENTS OF UFC 4-022-01, UFC 4-022-02, UFGS 34 71 13.19, UFGS 34 41 26.00, AND SDDCTEA PAMPHLET 55-15. FINAL DENIAL BARRIER SHALL REMAIN IN THE NORMALLY CLOSED MODE THEREFORE SHALL BE SELECTED WITH THE UNDERSTANDING OF THE FREQUENT USE. 11 THE OVERWATCH POSITION, IF PROVIDED, SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15 AND UFC 4-022-01. THE OVERWATCH POSITION SHALL BE ELEVATED, REACTIVE TO ONCOMING TRAFFIC/THREAT, SO AS TO DIRECT ANY AMMUNITION FIRE TOWARD GROUND SHOULD TARGET BE MISSED. OVERWATCH SHALL ALSO BE LOCATED A SAFE DISTANCE FROM FINAL DENIAL SHOULD IT BE DEPLOYED AND A WRECK OCCUR. 12 REVERSE ENTRY DEVICES SUCH AS DETECTION LOOPS, WHICH ARE THE PREFERRED METHOD, SHALL BE APPROVED BY BASE. IN ADDITION, SECURITY FORCES SHALL BE CONSULTED. 13 GATE NOT REQUIRED TO BE AT BASE PERIMETER. LOCATION TO BE BASE SPECIFIC. APPROX. 790' C HEAVY DUTY PAVEMENT STANDOFF DISTANCE 1 18' X' 17'-6" PER X-RAY MANUFACTURER RECOMMENDATIONS R27'-6" 2 ESCORT ACCESS 26' SE LF -R EJ EC TI ON SECURITY FORCES & ESCORT PARKING (10:1 TA PER) 7 R15'-6" LA NE R2' BYPASS LANE 12' ACCESS CONTROL (DROP ARM GATE) 5 40' R2' 25' POST & CABLE BARRIER, RETAINING WALL, OR OTHER APPROVED ROADWAY CONTAINMENT BARRIER 6 R5' REVERSE ENTRY DEVICE (TYP. SYM.) 12 20 ' SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL SIZE 22X34 SHEET 15' ESCORT ACCESS R65' 20' 3 B 4 COMMERCIAL INSPECTION & GATEHOUSE R45' APPROX. 540' R109' R55' (2) 12' GATES 13 20' 15' 20' 10' X' 37'-6" (2) 12' GATES 13 ISLAND TO BE INSTALLED ONLY IF X-RAY IS USED 16' 16' TRUCK HOLDING 8 (9 TRUCK CAPACITY) TRUCK X-RAY (OPTIONAL) R35' R35' AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: D 5 ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) 1 ESCORT WAITING AREA (2 TRUCK CAPACITY) 9 FINAL DENIAL CAPABILITY 10 0 25' 50' 100' SCALE: 1 " = 50' FDWD5022 Jacobs Project No.: Drawing Title: OVERWATCH 11 A COMMERCIAL ENTRY GATE CONSTRAINED CHASE VEHICLE 40' COMMERCIAL GATE (CONSTRAINED) SCHEMATIC Date: 1 MARCH 2015 Designed By: SM Drawn By: LW Checked By: MT Drawing No.: A-206 1 3 2 4 5 GENERAL SITE PLAN NOTES: KEY NOTES: 1. DESIGN ENTRY POINTS TO ALLOW ADEQUATE ASSESSMENT OF AUTHORIZATION OF APPROACHING VEHICLES, WHILE MAINTAINING SAFETY OF GATE GUARDS AND OTHER VEHICLES 1 MINIMUM STANDOFF DISTANCE SHALL BE DETERMINED PER UFC 2-100-01, UFC 4-010-02, AND SDDCTEA PAMPHLET 55-15. APPROACHING THE ENTRY POINT, WITHOUT DISRUPTING PEDESTRIAN OR VEHICULAR TRAFFIC FLOW.w MINIMUM TURNING RADIUS SHALL BE BASED ON ANTICIPATED LARGEST VEHICLE LIKELY TO USE THE FACILITY PER SDDCTEA PAMPHLET 55-15, AND UFC 4-022-01. 2. LIMIT SPEED OF VEHICLES BY USING CURVILINEAR ACCESS ROADS, SPEED HUMPS OR TEXTURED PAVEMENTS. IN CONFINED SITES, INCORPORATE A CURVILINEAR ACCESS ROAD, TRAFFIC CIRCLES AND/OR SMALL RADIUS TURNS IN ORDER TO LIMIT THE SPEED OF VEHICLES AND CREATE THE OPPORTUNITY FOR A MORE INTERESTING APPROACH. 3 SIZING OF INSPECTION AREAS SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15. 3. UTILIZE EXISTING NATURAL SITE FEATURES SUCH AS TOPOGRAPHY, WATER FEATURES, AND DENSE VEGETATION ALONG ROADWAY TO SECURE ENTRY AND EXIT PROCEDURES AND INCORPORATE NEW FEATURES WHERE APPROPRIATE. 4 TRUCK INSPECTION CONSIDERATIONS SHALL BE IN ACCORDANCE WITH UFC 4-022-01 AND SDDCTEA PAMPHLET 55-15. 501 North Broadway, St. Louise, MO 63102 5. MINIMIZE CLEAR SIGHT LINES INTO SITE BY POTENTIAL AGGRESSORS THROUGH SCREENING OR UTILIZATION OF NATURAL FEATURES 6 VEHICULAR CONTAINMENT BARRIER SHALL MEET THE REQUIREMENTS OF UFC 4-022-02 AND SDDCTEA PAMPHLET 55-15. 6. PROVIDE SELF-REJECTION LANE WITH TURNING RADII ADEQUATE FOR SEMI-TRUCKS PRIOR TO GATEHOUSE WHERE COMMERCIAL VEHICLES ARE PROHIBITED FROM ENTERING. 7 LANE TRANSITIONS SHALL BE ACHEIVED AT A 10:1 TAPER PER SDDCTEA PAMPHLET 55-15. 8. PROVIDE A FINAL DENIAL SYSTEM THAT WILL PROHIBIT UNAUTHORIZED VEHICLES FROM ENTERING THE SITE, BOTH ON THE INBOUND AND OUTBOUND SIDE. ACTIVE VEHICLE BARRIERS FOR COMMERCIAL ENTRIES ARE TO BE FUNCTION AT “NORMALLY CLOSED MODE”-GUARD OPENS AND CLOSES AVB FOR EACH VEHICLE ENTERING THE INSTALLATION. 9 RESPONSE ZONE LENGTH SHALL BE CALCULATED ON UFC 4-022-01, UFC 4-022-02, SDDCTEA PAMPHLET 55-15, LATEST EDITIONS, BASED ON GOVERNING THREAT SCENARIO (INBOUND/HIGH SPEED, OUTBOUND/HIGHSPEED, OR ONE OF THE COVERT ATTACKS) WHICH RESULTS IN THE LONGEST REQUIRED ZONE LENGTH. APPROACH ZONE LENGTH, RESPONSE ZONE SPEED REDUCING MEASURES, AND WRONG-WAY AND OVERSPEED DETECTION MEANS WILL IMPACT THE RESULTING OVERALL ACCESS CONTROL POINTS LENGTH. REFER TO THE DESIGN CRITERIA FOR THREAT ROUTE CALCULATIONS OVERVIEW.RESPONSE ZONE IS NOT APPLICABLE AT COMMERCIAL GATES. THE FINAL DENIAL BARRIER SHALL REMAIN IN THE NORMALLY CLOSED MODE. 9. INCORPORATE SITE LIGHTING WITH A MINIMUM AVERAGE OF 4 FOOT-CANDLES TO PROVIDE SECURITY PERSONNEL A CLEAR VIEW OF APPROACHING DRIVERS AND DRIVERS A CLEAR VIEW OF GATEHOUSE. 10. PROVIDE ADEQUATE EXISTING AND SELF-REJECTION LANES WITH TURNING RADII APPROPRIATE FOR SEMI-TRUCKS TO MINIMIZE TRAFFIC DISRUPTION. 11. VISITOR'S CENTER SHALL BE LOCATED SO THAT IT IS EASILY ACCESSIBLE, CLEARLY VISIBLE AND HAS THE CAPACITY FOR VEHICLES TO SELF-REJECT WITH MINIMAL TRAFFIC DISRUPTION. 10 FINAL DENIAL CAPABILITIES SHALL MEET THE REQUIREMENTS OF UFC 4-022-01, UFC 4-022-02, UFGS 34 71 13.19, UFGS 34 41 26.00, AND SDDCTEA PAMPHLET 55-15. IN THE COMMERCIAL LANE, THE FINAL DENIAL BARRIER SHALL REMAIN IN THE NORMALLY CLOSED MODE THEREFORE SHALL BE SELECTED WITH THE UNDERSTANDING OF THE FREQUENT USE. 11 THE OVERWATCH POSITION, IF PROVIDED, SHALL BE IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15 AND UFC 4-022-01. THE OVERWATCH POSITION SHALL BE ELEVATED, REACTIVE TO ONCOMING TRAFFIC/THREAT, SO AS TO DIRECT ANY AMMUNITION FIRE TOWARD GROUND SHOULD TARGET BE MISSED. OVERWATCH SHALL ALSO BE LOCATED A SAFE DISTANCE FROM FINAL DENIAL SHOULD IT BE DEPLOYED AND A WRECK OCCUR. 12 REVERSE ENTRY DEVICES SUCH AS DETECTION LOOPS, WHICH ARE THE PREFERRED METHOD, SHALL BE APPROVED BY BASE. IN ADDITION, SECURITY FORCES SHALL BE CONSULTED. 13 GATE NOT REQUIRED TO BE AT BASE PERIMETER. LOCATION TO BE BASE SPECIFIC. 14 VISITOR'S CENTER PARKING SHALL BE SIZED IN ACCORDANCE WITH SDDCTEA PAMPHLET 55-15. COMBINING VISITOR, DoD, AND COMMERCIAL IN ONE GATE IS NOT PREFERRED AND SHOULD ONLY BE USED IF SITE CONSTRAINTS DO NOT ALLOW FOR MULTIPLE GATES. VISITOR/DoD/COMMERCIAL GATE (UNCONSTRAINED) SCHEMATIC APPROX. 2000' SELF REJECTION LANE (ABLE TO ACCOMMODATE SEMI TRUCKS) POST & CABLE BARRIER, RETAINING WALL, OR OTHER APPROVED ROADWAY CONTAINMENT BARRIER 6 R.A.M. POST (AT HIGHER FPCONs) FINAL DENIAL CAPABILITY 10 R182' B R5' R25' 8 VISITOR/DoD GATEHOUSE ID CHECK BOOTH R21' :1 TA 25' PE 7 R25' 0 30' SECURITY FORCES PARKING 16' 16' PORTABLE TRAFFIC CONTROL STORAGE PORTABLE TRAFFIC CONTROL DEVICE 90' 36' R.A.M. POST (AT HIGHER FPCONs) STANDOFF DISTANCE 1 OVERWATCH 11 CHASE VEHICLE R55' FINAL DENIAL 10 CAPABILITY 4 TRUCK HOLDING 8 (9 TRUCK CAPACITY) 60' 120' 18' 3 COMMERCIAL INSPECTION Jacobs Project No.: FDWD5022 Drawing Title: VISITOR/DoD/COMMERCIAL ENTRY GATE UNCONSTRAINED REJECTION LANE BYPASS LANE X' PER X-RAY MANUFACTURER RECOMMENDATIONS 26' SCALE: 1 " = 60' R27'-6" ISLAND TO BE INSTALLED ONLY IF X-RAY IS USED 40' R15' RESPONSE ZONE 9 10:1 TAPER R 7 REJECTION LANE R182' PEDESTRIAN SIDEWALK 10 R5' 66' 4' ACCESS CONTROL (DROP ARM GATE) 5 2' (2) 15' GATES 13 R15' 28 ' ' VISITOR'S CENTER R15' CANOPY R5' 82' R5' R15' 22' R200' PORTABLE TRAFFIC CONTROL STORAGE 22' 2 4 3 POV INSPECTION 22' R25' R25' R25' 45' R1 R25' R5' R25' R35' REVERSE ENTRY DEVICE (TYP. SYM.) 12 R25' R5' 14 APPROX. 440' R20 0' R5' R25' A ACCESS CONTROL (DROP ARM GATE) 5 20' 82' REJECTION LANE REJECTION LANE R5' 28' R1 R35' VISITOR'S PARKING 14 R5' 12' 20' SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL SIZE 22X34 SHEET (2) 15' GATES 13 ALTERNATE POV INSPECTION AREA CHASE VEHICLE CHASE VEHICLE R5' R ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) 7. DESIGN PRIMARY VEHICLE INSPECTION AREAS SO THEY ARE NOT VISIBLE TO THE PUBLIC. 8 NUMBER OF ID CHECK STATIONS SHALL BE BASED ON TRAFFIC ENGINEERING ASSESSMENT, PER SDDCTEA PAMPHLET 55-15 TRUCK HOLDING SHALL BE BASED ON TRAFFIC ENGINEERING ASSESSMENT, PER SDDCTEA PAMPHLET 55-15. C 2705 Bee Cave Road, Suite 300, Austin, TX 78746 911 Central Parkway North, Suit 425, San Antonio, TX 78232 4. PROVIDE CLEAR SIGHT LINES WITHIN SITE TO ALLOW SECURITY PERSONNEL AND SECURITY DEVICES TO MONITOR THE SITE AND AREA BEYOND. 5 ACCESS CONTROL DEVICES, SUCH AS DROP ARM GATES, SHALL BE APPROVED BY BASE. D NOT FOR CONSTRUCTION AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: 2 15' X' HEAVY DUTY PAVEMENT X-RAY TRUCK (OPTIONAL) 40' 25' ESCORT WAITING AREA (2 TRUCK CAPACITY) SECURITY FORCES & ESCORT PARKING Date: 1 MARCH 2015 Designed By: SM Drawn By: LW Checked By: MT Drawing No.: A-207 1 3 2 4 GENERAL SIGNAGE NOTES: SIGN LEGEND: 1. ALL SITE PLANS SHALL COMPLY WITH THE UNITED FACILITIES CRITERIA (UFC 4-022-01) SECURITY ENGINEERING: ENTRY CONTROL FACILITIES / ACCESS CONTROL POINTS. ONLY IF EQUIPMENT IS USED SIGN DIRECTIONAL SYMBOL. FOR REFERENCE ONLY 2. ALL SIGNS SHALL COMPLY WITH THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). USE TABLES 2C-4, 2C-5, & 2C-6 FOR PLACEMENT DISTANCES OF WARNING SIGNS. GATE NAMES TBD BY BASE REQUIREMENTS 3. ALL SIGNAGE SELECTIONS AND PLACEMENT SHALL FOLLOW SDDCTEA PAMPHLET 55-15, SECTIONS 4, 7, 8, AND 10. SPEED LIMIT TO BE SET BY BASE D USE STANDARD SIGN USE IN TANDEM WITH "DO NOT ENTER" SIGN 2705 Bee Cave Road, Suite 300, Austin, TX 78746 911 Central Parkway North, Suit 425, San Antonio, TX 78232 501 North Broadway, St. Louise, MO 63102 4. ALL SIGN SELECTIONS SHOWN ARE NOTIONAL. FINAL SIGNAGE SHALL BE APPROVED BY THE BASE. 5. ALL SIGN SELECTIONS & PLACEMENT SHOULD BE BASED OFF OF CIRCULATION REQUIREMENTS. TO BE USED FOR ALL ACTIVE BARRIERS USE STANDARD SIGN 6. ADDITIONAL SIGNAGE MAY BE REQUIRED. USE AT INSPECTION & ID CHECK LOCATIONS NO LEFT TURN C ONE WAY ONE WAY ONE WAY ONE WAY 30' MIN 100' VISITOR'S PARKING B AIR FORCE CIVIL ENGINEER CENTER FACILITIES DYNAMIC PROTOTYPES DESIGN: FOR TRUCKS AND COMMERCIAL VEHICLES REQUIRING INSPECTION ONE WAY "BARRIER ACTIVATED WHEN FLASHING" USE THIS SIGN OR ANOTHER BASE APPROVED SIGN POV INSPECTION 100' 100' - 200' SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL SIZE 22X34 SHEET NOT FOR CONSTRUCTION ENTRY CONTROL FACILITIES / INSTALLATION ACCESS CONTROL POINTS (ECF/IACP) TBD ONE WAY 5 30' MIN VISITOR/DoD GATEHOUSE VISITOR'S CENTER ID CHECK BOOTH 0 OVERWATCH FINAL DENIAL CAPABILITIES ONE WAY 30' 60' 120' SCALE: 1 " = 60' Jacobs Project No.: FDWD5022 Drawing Title: A NOTIONAL SIGNAGE PLAN ONE WAY ONE WAY ONE WAY Date: 1 MARCH 2015 Designed By: SM Drawn By: KW Checked By: MT Drawing No.: A-208