1 2 3 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 D C B Jacobs Project No.: A 100% DESIGN November 21, 2011 FITNESS CENTER: MEGA 2 SIZE 100% DESIGN AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: FACILITIES DYNAMIC PROTOTYPES DESIGN FOR FITNESS CENTER - MEGA 2 SIZE FDWD1323 Drawing Title: COVER SHEET Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: G-000 1 2 3 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET NOT FOR CONSTRUCTION B Jacobs Project No.: A 100% DESIGN FITNESS CENTER: MEGA 2 SIZE C AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: D 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 FDWD1323 Drawing Title: BUILDING RENDERING Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: G-001 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET ENTRY VESTIBULE NOTES GENERAL NOTES 1. 1. 2. 3. PROVIDE A VESTIBULE STORAGE ROOM IN NORTHERNTIER ENTRIES FOR SNOW SHOVELS & SIDEWALK SALT. 4. 5. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED D NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 Vending 1.05 42 SF 9' - 6" Control Point/ Reception 1.03 249 SF Corridor 1.02 270 SF TV Equipment Issue/ Storage 1.06 175 SF Retail 1.04 51 SF 9' - 6" Control Point/ Reception 1.03 249 SF 10' - 6" PROVIDE SECURITY SYSTEM TV Lobby 1.01 1199 SF C TV 1 Lobby 1.01 1199 SF Entry Vestibule 1.00 9' - 6" 108 SF Optional Vestibule Storage 1.07 25 SF Entry Vestibule 1.00 108 SF MODULE 01-ENTRY - PLAN 1/8" = 1'-0" Fitness and Sports Manager Office 2.04 120 SF NCOIC Office 2.05 81 SF 2 Operations Manager Office 2.06 80 SF Corridor 1.02 270 SF Sports Program Manager Office 2.07 81 SF 9' - 0" Optional Vestibule Storage 1.07 25 SF MODULE 01 - ENTRY - RCP 1/8" = 1'-0" Fitness and Sports Manager Office 2.04 120 SF 3 Operations Manager Office 2.06 80 SF NCOIC Office 2.05 81 SF MODULE 01- ENTRY - AXON. Sports Program Manager Office 2.07 81 SF B 9' - 6" Corridor 2.03 172 SF 9' - 6" 9' - 6" 9' - 6" Corridor 2.03 172 SF 100% DESIGN Retail 1.04 51 SF FITNESS CENTER: MEGA 2 SIZE Equipment Issue/ Storage 1.06 175 SF 9' - 6" AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: Vending 1.05 42 SF Staff Workstations 2.00 787 SF Staff Workstations 2.00 787 SF 9' - 6" Corridor 2.08 211 SF Corridor 2.08 211 SF 0 4' 8' 16' SCALE: 1/8 " = 1' A Break Room 2.02 161 SF Conference/ Classroom 2.01 577 SF Break Room 2.02 161 SF 9' - 6" Jacobs Project No.: Conference/ Classroom 2.01 577 SF Drawing Title: 9' - 6" ENTRY & ADMINISTRATION Date: MODULE 02- ADMINISTRATION - PLAN 4 1/8" = 1'-0" MODULE 02 - ADMINISTRATION - RCP 5 1/8" = 1'-0" FDWD1323 6 MODULE 02- ADMINISTRATION - AXON. 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-101 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET HAWC/ FAC NOTES GENERAL NOTES 1. 1. 2. 3. THE HAWC AND FAC MODULES SHALL BE OF ADEQUATE DISTANCE FROM EACH OTHER IN FUTURE BUILDING DESIGNS SO THAT ANY OVERFLOW OF PEOPLE FROM THE FAC DOES NOT INTERRUPT THE DAILY OPERATIONS OF THE HAWC. 4. 5. D EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 Janitor Closet/Storage 3.06 61 SF 9' - 0" Break Area 3.04 124 SF 9' - 0" Restroom 3.05 64 SF 9' - 0" Corridor 3.07 439 SF Corridor 3.07 439 SF Classroom Area A 3.09 612 SF C Private Office 3.03 81 SF Director's Office 3.02 121 SF Classroom Area A 3.09 612 SF 9' - 0" 10' - 0" 9' - 0" Director's Office 3.02 121 SF Wellness Assessment Room 3.08 246 SF Private Office 3.03 81 SF 9' - 0" Support Staff Workstations 3.01 201 SF Support Staff Workstations 3.01 201 SF Classroom Area B 3.10 612 SF Reception/Waiting/Library 3.00 292 SF 1 B Classroom Area B 3.10 612 SF Reception/Waiting/Library 3.00 292 SF 10' - 0" MODULE 03 - HAWC- PLAN 1/8" = 1'-0" 2 Reception/Waiting 4.00 426 SF Individual Testing 4.01 326 SF MODULE 03 - HAWC - RCP 1/8" = 1'-0" Reception/Waiting 4.00 426 SF 3 MODULE 03-HAWC- AXON. 100% DESIGN Restroom 3.05 64 SF 9' - 0" Break Area 3.04 124 SF FITNESS CENTER: MEGA 2 SIZE Private Office 3.11 80 SF Wellness Assessment Room 3.08 246 SF 9' - 6" AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: Janitor Closet/Storage 3.06 61 SF 9' - 0" Fitness Assessment Testing 4.02 647 SF 0 Fitness Assessment Testing 4.02 647 SF 4' 8' 16' SCALE: 1/8 " = 1' Jacobs Project No.: Individual Testing 4.01 326 SF A 9' - 0" FDWD1323 Drawing Title: 9' - 0" HAWC & FAC Date: 4 MODULE 04-FAC- PLAN 1/8" = 1'-0" 5 MODULE 04 - FAC - RCP 1/8" = 1'-0" 6 MODULE 04 - FAC - AXON. 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-102 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 1. 2. 3. 4. 5. D MODULE 05 - RESTROOMS - PLAN 1/8" = 1'-0" 2 UP Stair A 6.00 194 SF C 4 MODULE 05 - RESTROOMS - RCP 1/8" = 1'-0" 3 MODULE 05 - RESTROOMS - AXON AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 1 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 Stair A 6.00 194 SF MODULE 06 - STAIRS - PLAN 1/8" = 1'-0" 5 MODULE 06 - STAIRS - RCP 1/8" = 1'-0" 6 MODULE 06 - STAIRS - AXON. Storage 7.04 2030 SF B 100% DESIGN Female Restrooms 5.01 143 SF Female Restrooms 5.01 143 SF NOT FOR CONSTRUCTION FITNESS CENTER: MEGA 2 SIZE Male Restrooms 5.00 143 SF Male Restrooms 5.00 143 SF EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED OPEN TO STRUCTURE ABOVE Storage 7.04 2030 SF OPEN TO STRUCTURE ABOVE Service Entrance and Receiving 7.00 574 SF Laundry 7.03 200 SF Service Entrance and Receiving 7.00 574 SF 0 Equipment Repair 7.01 203 SF Laundry 7.03 200 SF 4' 8' SCALE: 1/8 " = 1' Jacobs Project No.: A Equipment Repair 7.01 203 SF 7 MODULE 07 - SUPPORT - PLAN 1/8" = 1'-0" 8 MODULE 07 - SUPPORT - RCP 1/8" = 1'-0" FDWD1323 Drawing Title: Janitorial 7.02 120 SF Janitorial 7.02 120 SF 16' RESTROOMS, STAIRS & SUPPORT 9 MODULE 07 - SUPPORT - AXON. Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-103 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 1. 2. 3. 4. 5. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED D NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 RACQUETBALL COURT NOTES 1. Racquetball Court 2 8.02 800 SF C 40' - 0" Racquetball Court 1 8.01 800 SF Racquetball Court 2 8.02 800 SF 20' - 0" 20' - 0" WALL-MOUNTED STORAGE BOX WALL-MOUNTED STORAGE BOX Racquetball Spectator Area 8.03 160 SF B 1 MODULE 08 - RACQUETBALL COURTS - PLAN 1/8" = 1'-0" Racquetball Spectator Area 8.03 160 SF 2 MODULE 08 - RACQUETBALL COURTS - RCP 1/8" = 1'-0" 3 MODULE 08- RACQUETBALL COURTS- AXON. 0 4' 8' 100% DESIGN Racquetball Court 1 8.01 800 SF FITNESS CENTER: MEGA 2 SIZE 20' - 0" AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 20' - 0" DIMENSIONS GIVEN ARE BASED ON REGULATION SIZE RACQUETBALL COURTS AND SHOULD BE MAINTAINED IN FINAL BUILDING DESIGN. 16' SCALE: 1/8 " = 1' Jacobs Project No.: A FDWD1323 Drawing Title: RACQUETBALL Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-104 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET REINFORCED WALL TO THROW OBJECTS (e.g. MEDICINE BALLS) GENERAL NOTES 1. 2. 3. Group Exercise Storage 9.04 754 SF D Structured Activity/ Functional Fitness Room 9.05 977 SF Structured Activity/ Functional Fitness Room 9.05 977 SF 4. 5. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 GROUP EXERCISE NOTES Group Exercise Storage 9.04 754 SF 1. ASSUME CEILING HEIGHTS WILL VARY BASED ON FINAL DESIGN. SPACE SEPARATION LINE (TYP.) Group Exercise A 9.02 3743 SF Group Exercise A 9.02 3743 SF C Stretching Area A 9.03 150 SF Stretching Area A 9.03 150 SF TOE HOLD BAR SPACE SEPARATION LINE MOVEABLE PARTITION WALL B TOE HOLD BAR Group Exercise B 9.00 3743 SF 100% DESIGN AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: TOE HOLD BAR FITNESS CENTER: MEGA 2 SIZE MIRROR Stretching Area B 9.01 150 SF Stretching Area B 9.01 150 SF Group Exercise B 9.00 3743 SF 0 4' 8' 16' SCALE: 1/8 " = 1' Jacobs Project No.: A FDWD1323 Drawing Title: GROUP EXERCISE FLOOR PLAN & RCP Date: 1 MODULE 09- GROUP EXERCISE- PLAN 1/8" = 1'-0" 2 MODULE 09 - GROUP EXERCISE - RCP 1/8" = 1'-0" 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-105 1 2 3 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 5. 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: D NOT FOR CONSTRUCTION C B Jacobs Project No.: A 100% DESIGN 4. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED FITNESS CENTER: MEGA 2 SIZE 1. 2. 3. FDWD1323 Drawing Title: GROUP EXERCISE AXON. 1 MODULE 09 - GROUP EXERCISE - AXON. Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-106 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 1. 2. 3. 4. 5. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED D NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 CARDIO/ WEIGHT ROOM NOTES C SPACE SEPARATION LINE (TYP.) Cardio Area 10.03 5087 SF Selectorized Weights 10.04 3380 SF B Circulation 10.06 611 SF 0 4' 8' 100% DESIGN AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 5. PROVIDE KICK PLATES ON ALL WALLS IN WEIGHT ROOM. PROVIDE MIRRORS ON WALLS WHERE APPROPRIATE. PROVIDE TELEVISIONS WHERE APPROPRIATE. FITNESS PROGRAM MANAGER'S OFFICE & FITNESS ASSESSMENT ROOM SHALL BE ADJACENT TO THE CARDIO/ WEIGHT ROOM. ASSUME CEILING HEIGHTS WILL VARY BASED ON FINAL DESIGN. FITNESS CENTER: MEGA 2 SIZE 1. 2. 3. 4. Free Weights 10.05 4551 SF 16' SCALE: 1/8 " = 1' EXERCISE FLOOR MAT (TYP.) Jacobs Project No.: Crossover Machine 10.02 74 SF A SMALL STACKED LOCKERS (TYP.) Chin/Dip 10.01 90 SF Stretching 10.00 352 SF TOE BAR (TYP.) Fitness Program Manager's Office 10.07 150 SF DRINKING FOUNTAIN (TYP.) Fitness Assessment Room 10.08 125 SF Drawing Title: CARDIO/ WEIGHT ROOM - FLOOR PLAN Date: 1 MODULE 10- CARDIO/ WEIGHT ROOM- PLAN 1/8" = 1'-0" FDWD1323 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-107 1 2 3 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET Free Weights 10.05 4551 SF GENERAL NOTES 1. 2. 3. 4. D 5. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 CARDIO/ WEIGHT ROOM NOTES B Cardio Area 10.03 5087 SF Selectorized Weights 10.04 3380 SF 0 Fitness Program Manager's Office 10.07 150 SF A Fitness Assessment Room 10.08 125 SF 4' 8' 100% DESIGN C FITNESS CENTER: MEGA 2 SIZE 5. PROVIDE KICK PLATES ON ALL WALLS IN WEIGHT ROOM. PROVIDE MIRRORS ON WALLS WHERE APPROPRIATE. PROVIDE TELEVISIONS WHERE APPROPRIATE. FITNESS PROGRAM MANAGER'S OFFICE & FITNESS ASSESSMENT ROOM SHALL BE ADJACENT TO THE CARDIO/ WEIGHT ROOM. ASSUME CEILING HEIGHTS WILL VARY BASED ON FINAL DESIGN. AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 1. 2. 3. 4. 16' SCALE: 1/8 " = 1' Jacobs Project No.: FDWD1323 Drawing Title: Stretching 10.00 352 SF CARDIO/ WEIGHT ROOM - RCP Date: 1 MODULE 10 - CARDIO/ WEIGHT ROOM 1/8" = 1'-0" 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-108 1 2 3 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 1. 2. 3. 4. D 5. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 CARDIO/ WEIGHT ROOM NOTES C B Jacobs Project No.: A 100% DESIGN AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 5. PROVIDE KICK PLATES ON ALL WALLS IN WEIGHT ROOM. PROVIDE MIRRORS ON WALLS WHERE APPROPRIATE. PROVIDE TELEVISIONS WHERE APPROPRIATE. FITNESS PROGRAM MANAGER'S OFFICE & FITNESS ASSESSMENT ROOM SHALL BE ADJACENT TO THE CARDIO/ WEIGHT ROOM. ASSUME CEILING HEIGHTS WILL VARY BASED ON FINAL DESIGN. FITNESS CENTER: MEGA 2 SIZE 1. 2. 3. 4. FDWD1323 Drawing Title: CARDIO/ WEIGHT ROOM - AXON. 1 MODULE 10 - CARDIO/ WEIGHT ROOM - AXON. Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-109 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 1. 2. 3. 4. DRINKING FOUNTAIN (TYP.) DOUBLE-TIERED BENCH 5. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED D NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 FULL HEIGHT LOCKER (TYP.) Female Sauna or Steam Room 11.03 240 SF Male Sauna or Steam Room 11.10 240 SF LOCKER ROOM NOTES 1. Male Drying/Cooling Room 11.09 120 SF Female Drying/Cooling Room 11.04 120 SF ENSURE LIGHT IN SAUNA ROOM IS OUTSIDE OF TOUCHING RANGE OF USER. LIGHT COVER SHALL NOT BE GLASS. BENCH (TYP.) BENCH (TYP.) HANGING ROD (TYP.) C COUNTER WITH MIRROR (TYP.) Female Corridor 11.01 960 SF Male Corridor 11.11 960 SF SPACE SEPARATION LINE (TYP.) Female Lockers 11.02 4052 SF PAPER TOWEL DISPENSER (TYP.) Male Lockers 11.12 4052 SF OPENING IN COUNTER FOR TRASHCAN (TYP.) Female Restroom 11.06 600 SF Male Restroom 11.07 600 SF B 100% DESIGN BENCH (TYP.) FITNESS CENTER: MEGA 2 SIZE Male Showers 11.08 588 SF AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: Female Showers 11.05 588 SF WEIGHT SCALE (TYP.) PAPER TOWEL DISPENSER (TYP.) DRINKING FOUNTAIN (TYP.) Locker Room Entry 11.00 601 SF 0 4' 8' 16' SCALE: 1/8 " = 1' Jacobs Project No.: A FDWD1323 Drawing Title: LOCKER ROOM FLOOR PLAN 1 MODULE 11 - LOCKER ROOM - PLAN 1/8" = 1'-0" Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-110 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 1. 2. 3. Female Drying/Cooling Room 11.04 120 SF D Female Sauna or Steam Room 11.03 240 SF Male Drying/Cooling Room 11.09 120 SF Male Sauna or Steam Room 11.10 240 SF 4. 5. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 LOCKER ROOM NOTES 10' - 0" 10' - 0" 1. ENSURE LIGHT IN SAUNA ROOM IS OUTSIDE OF TOUCHING RANGE OF USER. LIGHT COVER SHALL NOT BE GLASS. 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" Female Corridor 11.01 960 SF Female Lockers 11.02 4052 SF Male Corridor 11.11 960 SF Female Restroom 11.06 600 SF Male Lockers 11.12 4052 SF Male Restroom 11.07 600 SF B 10' - 0" 10' - 0" 10' - 0" 100% DESIGN Male Showers 11.08 588 SF FITNESS CENTER: MEGA 2 SIZE Female Showers 11.05 588 SF C AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 10' - 0" 10' - 0" 10' - 0" Locker Room Entry 11.00 601 SF 10' - 0" 0 4' 8' 16' SCALE: 1/8 " = 1' Jacobs Project No.: A FDWD1323 Drawing Title: LOCKER ROOM RCP 1 MODULE 11 - LOCKER ROOM - RCP 1/8" = 1'-0" Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-111 1 2 3 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 1. 2. 3. 4. 5. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED D NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 LOCKER ROOM NOTES B Jacobs Project No.: A 100% DESIGN C FITNESS CENTER: MEGA 2 SIZE ENSURE LIGHT IN SAUNA ROOM IS OUTSIDE OF TOUCHING RANGE OF USER. LIGHT COVER SHALL NOT BE GLASS. AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 1. FDWD1323 Drawing Title: LOCKER ROOM AXON. 1 MODULE 11 - LOCKER ROOM - AXON. Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-112 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES DN 1. 2. 3. GUARDRAIL (TYP.) 4. D 5. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 TRACK NOTES Track A 12.00 10703 SF B 0 8' 16' 100% DESIGN C FITNESS CENTER: MEGA 2 SIZE TRACK IS COUNTED AS HALF SCOPE IN THE TOTAL BUILDING SQUARE FOOTAGE. AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 1. 32' SCALE: 1/16 " = 1' Jacobs Project No.: A FDWD1323 Drawing Title: TRACK A DN 1 MODULE 12- INDIVIDUAL TRACK A 1/16" = 1'-0" 2 MODULE 12 - INDIVIDUAL TRACK A- AXON. Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-113 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 1. 2. 3. DN 4. GUARDRAIL (TYP.) D 5. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 TRACK NOTES Track B 12.10 10703 SF B 0 8' 16' 100% DESIGN C FITNESS CENTER: MEGA 2 SIZE TRACK IS COUNTED AS HALF SCOPE IN THE TOTAL BUILDING SQUARE FOOTAGE. AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 1. 32' SCALE: 1/16 " = 1' Jacobs Project No.: DN A FDWD1323 Drawing Title: TRACK B MODULE 12 - INDIVIDUAL TRACK B- PLAN 1 1/16" = 1'-0" 2 MODULE 12 - INDIVIDUAL TRACK B- AXON. Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-114 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET SHOT CLOCK SHOT CLOCK GENERAL NOTES 1. 2. 3. 10' OFFSET CLEAR TO ROOF ABOVE FROM EDGE OF COURT (TYP.) 10' OFFSET CLEAR TO ROOF ABOVE FROM EDGE OF COURT (TYP.) 10' - 0" 10' - 0" DRINKING FOUNTAIN (TYP.) 4. 5. D EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 BLEACHERS (TYP.) BASKETBALL COURT NOTES SHOT CLOCK 10' - 0" 94' - 4" SHOT CLOCK 94' - 4" C 50' - 4" 10' - 0" 10' - 0" 50' - 4" 10' - 0" 10' - 0" 10' - 0" B SHOT CLOCK 100% DESIGN Basketball/ Volleyball Courts 13.00 19446 SF FITNESS CENTER: MEGA 2 SIZE 2. 3. 4. DIMENSIONS GIVEN ARE BASED ON REGULATION SIZE BASKETBALL COURTS AND SHOULD BE MAINTAINED IN FINAL BUILDING DESIGN. PROVIDE A PA SYSTEM FOR GAME ANNOUNCEMENTS. PROVIDE SHOT CLOCKS WHERE NEEDED. BASKETBALL COURT A WILL FIT INSIDE TRACK A & TRACK B. BASKETBALL COURT B WILL FIT INSIDE TRACK B. AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 1. SHOT CLOCK 0 4' 8' 16' SCALE: 1/8 " = 1' Jacobs Project No.: A Basketball Storage A 13.01 651 SF MODULE 13 - BASKETBALL COURT A - FLOOR PLAN 1 1/8" = 1'-0" Basketball Storage B 13.02 432 SF FDWD1323 Drawing Title: BASKETBALL A FLOOR PLAN Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-115 1 2 3 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 1. 2. 3. 4. D 5. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 BASKETBALL COURT NOTES C B Jacobs Project No.: A 100% DESIGN AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 2. 3. 4. DIMENSIONS GIVEN ARE BASED ON REGULATION SIZE BASKETBALL COURTS AND SHOULD BE MAINTAINED IN FINAL BUILDING DESIGN. PROVIDE A PA SYSTEM FOR GAME ANNOUNCEMENTS. PROVIDE SHOT CLOCKS WHERE NEEDED. BASKETBALL COURT A WILL FIT INSIDE TRACK A & TRACK B. BASKETBALL COURT B WILL FIT INSIDE TRACK B. FITNESS CENTER: MEGA 2 SIZE 1. FDWD1323 Drawing Title: BASKETBALL A AXON. 1 MODULE 13 - BASKETBALL COURT A - AXON. Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-116 1 3 2 4 SHOT CLOCK 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET SHOT CLOCK GENERAL NOTES 1. 2. 3. BLEACHERS (TYP.) 4. 5. 10' - 0" NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 BASKETBALL COURT NOTES Athletic Storage A 13.11 492 SF C 10' - 0" 50' - 4" 10' - 0" 10' - 0" 50' - 4" 10' - 0" SHOT CLOCK 94' - 4" 94' - 4" SHOT CLOCK Basketball/ Volleyball Courts 13.10 20971 SF Athletic Storage B 13.12 492 SF 10' - 0" 10' - 0" B 100% DESIGN 2. 3. 4. DIMENSIONS GIVEN ARE BASED ON REGULATION SIZE BASKETBALL COURTS AND SHOULD BE MAINTAINED IN FINAL BUILDING DESIGN. PROVIDE A PA SYSTEM FOR GAME ANNOUNCEMENTS. PROVIDE SHOT CLOCKS WHERE NEEDED. BASKETBALL COURT A WILL FIT INSIDE TRACK A & TRACK B. BASKETBALL COURT B WILL FIT INSIDE TRACK B. FITNESS CENTER: MEGA 2 SIZE 1. AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 10' - 0" D EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED 0 4' 8' 16' SCALE: 1/8 " = 1' Jacobs Project No.: A FDWD1323 Drawing Title: BASKETBALL B FLOOR PLAN SHOT CLOCK SHOT CLOCK Date: 1 MODULE 13 - BASKETBALL COURT B - PLAN 1/8" = 1'-0" 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-117 1 2 3 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 1. 2. 3. 4. D 5. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 BASKETBALL COURT NOTES C B Jacobs Project No.: A 100% DESIGN AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 2. 3. 4. DIMENSIONS GIVEN ARE BASED ON REGULATION SIZE BASKETBALL COURTS AND SHOULD BE MAINTAINED IN FINAL BUILDING DESIGN. PROVIDE A PA SYSTEM FOR GAME ANNOUNCEMENTS. PROVIDE SHOT CLOCKS WHERE NEEDED. BASKETBALL COURT A WILL FIT INSIDE TRACK A & TRACK B. BASKETBALL COURT B WILL FIT INSIDE TRACK B. FITNESS CENTER: MEGA 2 SIZE 1. FDWD1323 Drawing Title: BASKETBALL B AXON. 1 MODULE 13 - BASKETBALL COURT B - AXON. Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-118 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 1. 2. 3. 4. D 5. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 Vending 14.07 42 SF Equipment Issue/ Storage 14.06 175 SF Equipment Issue/ Storage 14.06 175 SF C Control Point/ Reception 14.05 249 SF Corridor 14.04 263 SF Juice Bar 14.03 156 SF Juice Bar Seating 14.02 250 SF Juice Bar Seating 14.02 250 SF Lobby 14.01 1176 SF Lobby 14.01 1176 SF Entry Vestibule 14.00 108 SF B 1 MODULE 14 - ENHANCED ENTRY - PLAN 1/8" = 1'-0" 2 MODULE 14 - ENHANCED ENTRY - RCP 1/8" = 1'-0" 3 MODULE 14- ENHANCED ENTRY - AXON. 0 4' 8' 100% DESIGN Corridor 14.04 263 SF Juice Bar 14.03 156 SF FITNESS CENTER: MEGA 2 SIZE Control Point/ Reception 14.05 249 SF AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: Vending 14.07 42 SF 16' SCALE: 1/8 " = 1' Jacobs Project No.: A FDWD1323 Drawing Title: ENHANCED ENTRY WITH JUICE BAR Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-201 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 1. 2. 3. 4. 5. D Expanded Retail Area 15.00 100 SF EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 Expanded Retail Area 15.00 100 SF MASSAGE ROOM NOTES 1. MODULE 15 - EXPANDED RETAIL - RCP 1/8" = 1'-0" 7 MODULE 15 - EXPANDED RETAIL - AXON. PARTIAL HEIGHT GLASS PARTITION C Parent/ Child Area 16.00 851 SF Parent/ Child Area 16.00 851 SF TV WALL MOUNTED SHELVING MODULE 16 - PARENT/ CHILD AREA - PLAN 8 1/8" = 1'-0" 9 MODULE 16 - PARENT/ CHILD AREA - RCP 1/8" = 1'-0" 10 MODULE 16 - PARENT/ CHILD AREAL - AXON. B Massage Room 17.00 120 SF Massage Room 17.00 120 SF 1 MODULE 17 - MASSAGE ROOM - PLAN 1/8" = 1'-0" 2 MODULE 17 - MASSAGE ROOM - RCP 1/8" = 1'-0" 3 100% DESIGN 6 FITNESS CENTER: MEGA 2 SIZE MODULE 15 - EXPANDED RETAIL - PLAN 1/8" = 1'-0" AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 5 ENSURE A HIGH STC RATING IN THE MASSAGE ROOM. MODULE 17 - MASSAGE ROOM - AXON. 0 4' 8' 16' SCALE: 1/8 " = 1' Jacobs Project No.: Additional Stretching Area 18.00 666 SF A 4 MODULE 18 - ADDITIONAL STRETCHING AREA - PLAN 1/8" = 1'-0" Additional Stretching Area 18.00 666 SF 11 MODULE 18 - ADDITIONAL STRETCHING AREA - RCP 1/8" = 1'-0" FDWD1323 Drawing Title: EXPANDED RETAIL, PARENT/ CHILD AREA, MASSAGE ROOM & ADD.STRETCHING AREA 12 MODULE 18 - ADDITIONAL STRETCHING AREA - RCP Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-202 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 1. 2. 3. DRINKING FOUNTAIN (TYP.) Female Showers 19.06 588 SF Male Showers 19.13 588 SF FULL HEIGHT LOCKER (TYP.) BENCH (TYP.) 4. 5. D EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 LOCKER ROOM NOTES BENCH (TYP.) 1. ENSURE LIGHT IN SAUNA ROOM IS OUTSIDE OF TOUCHING RANGE OF USER. LIGHT COVER SHALL NOT BE GLASS. HANGING ROD (TYP.) Female Corridor 19.05 1100 SF Female Lockers 19.04 3871 SF Male Corridor 19.14 1100 SF Male Lockers 19.15 3871 SF WEIGHT SCALE (TYP.) DOUBLE-TIERED BENCH B Female Sauna or Steam Room 19.08 240 SF Male Sauna or Steam Room 19.11 240 SF Female Drying/Cooling Room 19.09 120 SF Male Drying/Cooling Room 19.10 120 SF Family Lockers/Changing 19.01 478 SF Female Distinguished Visitor Locker Room 19.03 667 SF Male Distinguished Visitor Locker Room 1135 667 SF 0 4' 8' 16' SCALE: 1/8 " = 1' BENCH (TYP.) A BENCH (TYP.) 100% DESIGN Male Restroom 19.12 599 SF Female Restroom 19.07 599 SF OPENING IN COUNTER FOR TRASHCAN BELOW (TYP.) FITNESS CENTER: MEGA 2 SIZE C AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: COUNTER WITH MIRROR (TYP.) Janitor 19.02 74 SF DRINKING FOUNTAIN (TYP.) Locker Room Entry 19.00 608 SF Janitor 19.17 74 SF Jacobs Project No.: FDWD1323 Drawing Title: ENHANCED LOCKER ROOM - FLOOR PLAN MODULE 19- ENHANCED LOCKER ROOM - PLAN 1 1/8" = 1'-0" Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-203 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 1. 2. 3. 10' - 0" 4. 5. D LOCKER ROOM NOTES 10' - 0" 10' - 0" 1. Male Showers 19.13 588 SF ENSURE LIGHT IN SAUNA ROOM IS OUTSIDE OF TOUCHING RANGE OF USER. LIGHT COVER SHALL NOT BE GLASS. 10' - 0" AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: Female Showers 19.06 588 SF 10' - 0" 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 C 10' - 0" Female Corridor 19.05 1100 SF 10' - 0" Male Restroom 19.12 599 SF Female Restroom 19.07 599 SF 10' - 0" 10' - 0" Female Lockers 19.04 3871 SF Male Lockers 19.15 3871 SF Female Sauna or Steam Room 19.08 240 SF B Male Corridor 19.14 1100 SF Female Drying/Cooling Room 19.09 120 SF Male Sauna or Steam Room 19.11 240 SF 10' - 0" 10' - 0" 10' - 0" 10' - 0" Male Drying/Cooling Room 19.10 120 SF 10' - 0" 10' - 0" 100% DESIGN Male Showers 19.13 588 SF 10' - 0" NOT FOR CONSTRUCTION FITNESS CENTER: MEGA 2 SIZE Female Showers 19.06 588 SF EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED 10' - 0" 10' - 0" Female Distinguished Visitor Locker Room 19.03 667 SF 10' - 0" Family Lockers/Changing 19.01 478 SF 10' - 0" A Male Distinguished Visitor Locker Room 1135 667 SF 10' - 0" 0 4' 8' 16' SCALE: 1/8 " = 1' 10' - 0" Jacobs Project No.: 10' - 0" 10' - 0" FDWD1323 10' - 0" Drawing Title: Locker Room Entry 19.00 608 SF Janitor 19.02 74 SF 10' - 0" 10' - 0" Janitor 19.17 74 SF ENHANCED LOCKER ROOM - RCP Date: 1 MODULE 19 - ENHANCED LOCKER ROOM - RCP 1/8" = 1'-0" 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-204 1 2 3 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES 1. 2. 3. 4. 5. D EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 LOCKER ROOM NOTES B Jacobs Project No.: A 100% DESIGN C FITNESS CENTER: MEGA 2 SIZE ENSURE LIGHT IN SAUNA ROOM IS OUTSIDE OF TOUCHING RANGE OF USER. LIGHT COVER SHALL NOT BE GLASS. AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 1. FDWD1323 Drawing Title: ENHANCED LOCKER ROOM - AXON. 1 MODULE 19 - ENHANCED LOCKER ROOM - AXON. Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-205 1 2 3 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET GENERAL NOTES D 5. NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 OPEN TO STRUCTURE ABOVE Mechanical 20.01 5251 SF C Communications 20.3 200 SF B Communications 20.3 200 SF 1 OPEN TO STRUCTURE ABOVE Electrical 20.2 200 SF MODULE 20 - SUPPORT - PLAN 1/8" = 1'-0" AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: Mechanical 20.01 5251 SF 2 Electrical 20.2 200 SF OPEN TO STRUCTURE ABOVE MODULE 20 - SUPPORT - RCP 1/8" = 1'-0" 0 4' 8' 100% DESIGN 4. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED FITNESS CENTER: MEGA 2 SIZE 1. 2. 3. 16' SCALE: 1/8 " = 1' Jacobs Project No.: A FDWD1323 Drawing Title: SUPPORT - FLOOR PLAN & RCP Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-301 1 2 3 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET D 4. 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 5. EVERY WALL IS GENERIC UNLESS SPECIFICALLY NOTED EVERY WALL IS A PLACE HOLDER AS THE MODULES ARE COMBINED TO CREATE A FACILITY, DISCRETION SHOULD BE USED AS TO WHICH WALLS NEED TO BE MOVED, ADDED OR REMOVED IF NO WALL IS PRESENT, IT IS THE DESIGN INTENT TO LEAVE THAT SPACE OPEN TO ADJACENT SPACES WITHIN THE FACILITY ALL FURNITURE IS A PLACE HOLDER UNLESS SPECIFICALLY NOTED C B 1 MODULE 20 - SUPPORT - AXON. Jacobs Project No.: A 100% DESIGN 1. 2. 3. NOT FOR CONSTRUCTION FITNESS CENTER: MEGA 2 SIZE GENERAL NOTES FDWD1323 Drawing Title: SUPPORT - AXON. Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-302 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET INDIVIDUAL MODULES SCALE: 1/32" = 1'0" NOT FOR CONSTRUCTION MEGA MODULE NOTES 3. HAWC 7. SUPPORT 13B. BASKETBALL/ VOLLEYBALL COURTS 19. ENHANCED LOCKER ROOM 1. MEGA MODULE IS PROVIDED TO ILLUSTRATE AN OPTIONAL WAY OF ARRANGING SOME OF THE INDIVIDUAL MODULES. THE MEGA MODULE IS NOT INTENDED TO CONSTITUTE A FINAL DESIGN. MEGA MODULE - FLOOR PLAN SCALE: 1/16" = 1'0" Janitorial Service Entrance & Receiving Stairs B Laundry Athletic Storage A Storage Women's Changing Area Men's Changing Area Janitor Closet/Storage 100% DESIGN C FITNESS CENTER: MEGA 2 SIZE D AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 Corridor Athletic Storage B Wellness Assessment Private Office Room 20.21 74 SF Break Area Restroom 0 8' 16' Classroom Area A 32' 64' SCALE: 1/32 " = 1' Private Director's Office Office 0 8' 16' 32' SCALE: 1/16 " = 1' Athletic Storage C Jacobs Project No.: Workstations A Basketball/ Volleyball Courts Classroom Area B Locker Rooms Reception/ Waiting Corridor FDWD1323 Drawing Title: MEGA MODULE FLOOR PLAN Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-401 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET INDIVIDUAL MODULES BUILDING - FIRST FLOOR PLAN SCALE: 1/32" = 1'0" SCALE: 1" = 20' BUILDING NOTES 1. 1. ENTRY 2. ADMINISTRATION 3. HAWC THIS BUILDING LAYOUT IS PROVIDED TO ILLUSTRATE ONE POSSIBLE WAY OF ARRANGING THE INDIVIDUAL MODULES. IT IS NOT INTENDED TO CONSTITUTE A FINAL DESIGN. MEGA MODULE NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 D Stairs UP Janitorial Service Entrance & Receiving Athletic Storage A 9. GROUP EXERCISE Athletic Storage B Women's Changing Area Break Area Men's Changing Area Janitor Closet/Storage Wellness Assessment Private Room Office C Restroom Classroom Area A Private Director's Office Office Workstations Basketball/ Volleyball Courts 10. CARDIO/ WEIGHT ROOM 13B. BASKETBALL/ VOLLEYBALL COURTS Vestibule Locker Rooms Classroom Area B Waiting/Library Juice Bar Seating Juice Bar UP Corridor Corridor Racquetball Court 2 Lobby Vending Sports Program Manager Office Break Room Conference/ Classroom Equipment Issue/ Storage B Fitness and Sports Manager Office Parent/ Child Area Staff Workstations Operations Manager Office Fitness Massage Program Room Manager Office Fitness Assessment Room Racquetball Spectator Area Elevator Racquetball Court 1 Cardio/ Weight Room Stairs NCOIC Office Group Exercise A 16. PARENT/ CHILD AREA 100% DESIGN Storage FITNESS CENTER: MEGA 2 SIZE 8. RACQUETBALL AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: 7. SUPPORT Laundry 19. ENHANCED LOCKER ROOMS Selectorized Weight Area 0 8' 16' 32' 64' SCALE: 1/32 " = 1' 0' 40' SCALE: 1" = 20' Group Exercise B 17. MASSAGE ROOM 20' Jacobs Project No.: A FDWD1323 Drawing Title: Free Weights Area Structured Activity/ Functional Fitness Room BUILDING - FIRST FLOOR PLAN Group Exercise Storage Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-501 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET BUILDING 1 - SECOND FLOOR PLAN INDIVIDUAL MODULES SCALE: 1/32" = 1'0" BUILDING NOTES 1. 3. FAC 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 DN D NOT FOR CONSTRUCTION THIS BUILDING LAYOUT IS PROVIDED TO ILLUSTRATE ONE POSSIBLE WAY OF ARRANGING THE INDIVIDUAL MODULES. IT IS NOT INTENDED TO CONSTITUTE A FINAL DESIGN. Stairs 10. CARDIO/ WEIGHT ROOM OPEN TO BASKETBALL/ VOLLEYBALL COURTS BELOW Janitor C Stretching/ Cardio 12B. TRACK DN Fitness Assessment Testing Women's Restroom DN OPEN TO BELOW Men's Restroom OPEN TO RACQUETBALL COURT BELOW OPEN TO LOBBY BELOW Individual Testing Reception/ Workstations Cardio Elevator Machine Room Elevator OPEN TO BELOW OPEN TO RACQUETBALL COURT BELOW DN B 100% DESIGN ROOF BELOW FITNESS CENTER: MEGA 2 SIZE AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: Mechanical OPEN TO GROUP EXERCISE BELOW 0 8' 16' 32' 64' SCALE: 1/32 " = 1' 0' 20' 40' SCALE: 1" = 20' OPEN TO BELOW Jacobs Project No.: A FDWD1323 Drawing Title: DN OPEN TO STRUCTURED ACTIVITY SPACE BELOW OPEN TO EXERCISE STORAGE BELOW BUILDING SECOND FLOOR PLAN Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-502 1 2 3 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET BUILDING NOTES 1. THIS BUILDING LAYOUT IS PROVIDED TO ILLUSTRATE ONE POSSIBLE WAY OF ARRANGING THE INDIVIDUAL MODULES. IT IS NOT INTENDED TO CONSTITUTE A FINAL DESIGN. NOT FOR CONSTRUCTION C B Jacobs Project No.: A 100% DESIGN AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: D FITNESS CENTER: MEGA 2 SIZE 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 FDWD1323 Drawing Title: BUILDING - AXON. Date: 1 BUILDING 1 - AXON. 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-503 1 3 2 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET B A 10.00 10.01 10.02 10.03 10.04 10.05 10.06 10.07 10.08 11.00 11.01 11.02 11.03 11.04 11.05 11.06 11.07 11.08 11.09 11.10 11.11 11.12 12.00 12.10 13.00 13.01 13.02 13.10 13.11 13.12 West Wall Ceiling Ceiling Finish Height Comments Area 108 SF 1199 SF 270 SF 249 SF 51 SF 42 SF 175 SF 25 SF 787 SF 577 SF 161 SF 172 SF 120 SF 81 SF 80 SF 81 SF 211 SF 292 SF 201 SF 121 SF 81 SF 124 SF 64 SF 61 SF 439 SF 246 SF 612 SF 612 SF 80 SF 426 SF 326 SF 647 SF 143 SF 143 SF 194 SF 574 SF 203 SF 120 SF 200 SF 2030 SF 800 SF 800 SF 160 SF 3743 SF 150 SF 3743 SF 150 SF 754 SF 977 SF 352 SF 90 SF 74 SF 5087 SF 3380 SF 4551 SF 611 SF 150 SF 125 SF 601 SF 960 SF 4052 SF 240 SF 120 SF 588 SF 600 SF 600 SF 588 SF 120 SF 240 SF 960 SF 4052 SF 10703 SF 10703 SF 19446 SF 651 SF 432 SF 20971 SF 492 SF 492 SF Room Number Room Name 14.00 Entry Vestibule 14.01 Lobby 14.02 Juice Bar Seating 14.03 Juice Bar 14.04 Corridor 14.05 Control Point/ Reception 14.06 Equipment Issue/ Storage 14.07 Vending 14.16 Wellness Assessment Room 14.17 Classroom Area A 14.18 Workstations 14.19 Janitor Closet/Storage 14.20 Restroom 14.21 Private Office 14.22 Director's Office 14.23 HAWC Corridor 14.24 Break Area 14.25 Classroom Area B 14.26 Waiting/Library 14.27 Mechanical 14.28 Massage Room 14.29 Stairs 14.33 Elevator 14.34 Elevator Machine Room 14.35 Vestibule 15.00 Expanded Retail Area 16.00 Parent/ Child Area 17.00 Massage Room 18.00 Additional Stretching Area 19.00 Locker Room Entry 19.01 Family Lockers/Changing 19.02 Janitor 19.03 Female Distinguished Visitor Locker Room 19.04 Female Lockers 19.05 Female Corridor 19.06 Female Showers 19.07 Female Restroom 19.08 Female Sauna or Steam Room 19.09 Female Drying/Cooling Room 19.10 Male Drying/Cooling Room 19.11 Male Sauna or Steam Room 19.12 Male Restroom 19.13 Male Showers 19.14 Male Corridor 19.15 Male Lockers 19.17 Janitor 20.01 Mechanical 20.2 Electrical 20.3 Communications 20.4 Storage 20.5 Service Entrance & Receiving 20.6 Laundry 20.7 Janitorial 20.8 Wellness Assessment Room 20.9 Classroom Area A 20.10 Workstations 20.11 Janitor Closet/Storage 20.12 Restroom 20.13 Private Office 20.14 Director's Office 20.15 HAWC Corridor 20.16 Break Area 20.17 Classroom Area B 20.19 Corridor 20.20 Private Office 20.21 Private Office Floor Finish Base Finish West Wall Ceiling Ceiling Finish Height Comments Area 108 SF 1176 SF 250 SF 156 SF 263 SF 249 SF 175 SF 42 SF 173 SF 553 SF 557 SF 56 SF 64 SF 81 SF 121 SF 351 SF 119 SF 553 SF 189 SF 3817 SF 190 SF 227 SF 46 SF 77 SF 212 SF 100 SF 851 SF 120 SF 666 SF 608 SF 478 SF 74 SF 667 SF 3871 SF 1100 SF 588 SF 599 SF 240 SF 120 SF 120 SF 240 SF 599 SF 588 SF 1100 SF 3871 SF 74 SF 5251 SF 200 SF 200 SF 2606 SF 779 SF 222 SF 133 SF 178 SF 553 SF 557 SF 59 SF 64 SF 81 SF 121 SF 342 SF 121 SF 553 SF 1547 SF 77 SF 74 SF NOT FOR CONSTRUCTION 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 Jacobs Project No.: 100% DESIGN C Entry Vestibule Lobby Corridor Control Point/ Reception Retail Vending Equipment Issue/ Storage Optional Vestibule Storage Staff Workstations Conference/ Classroom Break Room Corridor Fitness and Sports Manager Office NCOIC Office Operations Manager Office Sports Program Manager Office Corridor Reception/Waiting/Library Support Staff Workstations Director's Office Private Office Break Area Restroom Janitor Closet/Storage Corridor Wellness Assessment Room Classroom Area A Classroom Area B Private Office Reception/Waiting Individual Testing Fitness Assessment Testing Male Restrooms Female Restrooms Stair A Service Entrance and Receiving Equipment Repair Janitorial Laundry Storage Racquetball Court 1 Racquetball Court 2 Racquetball Spectator Area Group Exercise B Stretching Area B Group Exercise A Stretching Area A Group Exercise Storage Structured Activity/ Functional Fitness Room Stretching Chin/Dip Crossover Machine Cardio Area Selectorized Weights Free Weights Circulation Fitness Program Manager's Office Fitness Assessment Room Locker Room Entry Female Corridor Female Lockers Female Sauna or Steam Room Female Drying/Cooling Room Female Showers Female Restroom Male Restroom Male Showers Male Drying/Cooling Room Male Sauna or Steam Room Male Corridor Male Lockers Track A Track B Basketball/ Volleyball Courts Basketball Storage A Basketball Storage B Basketball/ Volleyball Courts Athletic Storage A Athletic Storage B Base Finish FITNESS CENTER: MEGA 2 SIZE D 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 4.00 4.01 4.02 5.00 5.01 6.00 7.00 7.01 7.02 7.03 7.04 8.01 8.02 8.03 9.00 9.01 9.02 9.03 9.04 9.05 Room Name Floor Finish ROOM SCHEDULE FINISHES WALLS North Wall East Wall South Wall AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: Room Number ROOM SCHEDULE FINISHES WALLS North Wall East Wall South Wall FDWD1323 Drawing Title: ROOM SCHEDULE Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-601 1 2 3 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET DOOR SCHEDULE B A 1.00A 1.00B 1.06A 1.07A 2.01A 2.01B 2.01C 2.02A 2.03A 2.04A 2.05A 2.06A 2.07A 2.08A 3.04A 3.05A 3.06A 3.07A 3.07B 3.09A 3.10A 3.11A 4.00A 4.01A 4.02A 5.00A 5.01A 6.00A 7.00A 7.00B 7.02A 7.03A 7.04A 7.04B 7.04C 8.00A 8.02A 9.00A 9.00B 9.02A 9.02B 9.04A 9.04B 9.04C 9.05B 9.05C 10.07A 10.08A 11.01A 11.03A 11.04A 11.09A 11.10A 11.11A 12.00A 12.00B 12.10A 12.10B 13.00A 13.00B 13.00C 13.00D 13.01A 13.01B 13.02A 13.10A 13.10B 13.10C 13.10D 13.10E 13.10F 13.11A 13.12A 14.00A 14.00B 14.03A 14.06A 16.00A 16.00B 17.00A 19.01A 19.01B 19.01C 19.01D 19.02 19.04A 19.05A 19.08A 19.09A 19.10A 19.11A 19.14A 19.15A 19.17A 20.01A 20.01B 20.2A 20.3A 6' - 0" 6' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 4" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 5' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 5' - 8" 5' - 8" 5' - 8" 3' - 0" 3' - 0" 3' - 0" 6' - 0" 10' - 0" 3' - 0" 6' - 0" 6' - 0" 6' - 0" 10' - 0" 3' - 0" 3' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 3' - 0" 3' - 0" 6' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 10' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 10' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 3' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 2" 0' - 2" 0' - 2" 0' - 1 1/2" 0' - 1 1/2" 0' - 2" 0' - 2" 0' - 2" 0' - 1 1/2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" Comments 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 SLIDING DOOR SLIDING DOOR GLASS STOREFRONT DOORS GLASS STOREFRONT DOORS 0' - 1 1/2" 0' - 1 1/2" 0' - 2" 0' - 2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 1 1/2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" NOT FOR CONSTRUCTION Jacobs Project No.: 100% DESIGN Height Frame Material Finish Jamb Head FITNESS CENTER: MEGA 2 SIZE C Width Door Thickness Material Finish Glazing Fire Rating Hardware Type AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: D Door Number FDWD1323 Drawing Title: DOOR SCHEDULE Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-602 1 2 3 4 5 SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON A FULL 22X34 SHEET NOT FOR CONSTRUCTION WINDOW SCHEDULE B 911 Central Parkway N., Suite 425 San Antonio, TX 78323 501 North Broadway, St. Louis, Missouri 63102-2121 Jacobs Project No.: A 100% DESIGN Manufacturer Head Height Comments FITNESS CENTER: MEGA 2 SIZE C Type Glazing Model Material Finish Head Jamb Sill Thickness Type AIR FORCE CENTER FOR ENGINEERING AND THE ENVIRONMENT (AFCEE) FACILITIES DYNAMIC PROTOTYPES DESIGN FOR: D R.O. Type Mark Width Height FDWD1323 Drawing Title: WINDOW SCHEDULE Date: 21 NOVEMBER 2011 Designed By: JN/MRB/OF Drawn By: JN/MRB/OF Checked By: JS Drawing No.: A-603