ab210965 – Mouse Myoglobin SimpleStep ELISA® Kit Instructions for use: For the quantitative measurement of Myoglobin in mouse serum, plasma, and cell culture supernatant, cell and tissue extract samples. This product is for research use only and is not intended for diagnostic use. Table of Contents INTRODUCTION 1 1. BACKGROUND 1 2. ASSAY SUMMARY 2 GENERAL INFORMATION 3 3. PRECAUTIONS 3 4. STORAGE AND STABILITY 3 5. MATERIALS SUPPLIED 3 6. MATERIALS REQUIRED, NOT SUPPLIED 4 7. LIMITATIONS 4 8. TECHNICAL HINTS 4 ASSAY PREPARATION 6 9. 6 REAGENT PREPARATION 10. STANDARD PREPARATION 11. SAMPLE PREPARATION 12. PLATE PREPARATION 7 9 12 ASSAY PROCEDURE 13 13. 13 ASSAY PROCEDURE DATA ANALYSIS 15 14. CALCULATIONS 15 15. TYPICAL DATA 16 16. TYPICAL SAMPLE VALUES 18 17. ASSAY SPECIFICITY 23 18. SPECIES REACTIVITY 24 RESOURCES 25 19. TROUBLESHOOTING 25 20. NOTES 26 INTRODUCTION INTRODUCTION 1. BACKGROUND Myoglobin in vitro SimpleStep ELISA® (Enzyme-Linked Immunosorbent Assay) kit is designed for the quantitative measurement of Myoglobin protein in mouse serum, plasma, and cell culture supernatant, cell and tissue extract samples. The SimpleStep ELISA® employs an affinity tag labeled capture antibody and a reporter conjugated detector antibody which immunocapture the sample analyte in solution. This entire complex (capture antibody/analyte/detector antibody) is in turn immobilized via immunoaffinity of an anti-tag antibody coating the well. To perform the assay, samples or standards are added to the wells, followed by the antibody mix. After incubation, the wells are washed to remove unbound material. TMB substrate is added and during incubation is catalyzed by HRP, generating blue coloration. This reaction is then stopped by addition of Stop Solution completing any color change from blue to yellow. Signal is generated proportionally to the amount of bound analyte and the intensity is measured at 450 nm. Optionally, instead of the endpoint reading, development of TMB can be recorded kinetically at 600 nm. Myoglobin is an oxygen- and iron-binding protein involved in the transportation of oxygen within muscles. Upon muscle injury, myoglobin can also be found in the bloodstream. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 1 INTRODUCTION 2. ASSAY SUMMARY Remove appropriate number of antibody coated well strips. Equilibrate all reagents to room temperature. Prepare all reagents, samples, and standards as instructed. Add standard or sample to appropriate wells. Add Antibody Cocktail to all wells. Incubate at room temperature. Aspirate and wash each well. Add TMB Substrate to each well and incubate. Add Stop Solution at a defined endpoint. Alternatively, record color development kinetically after TMB substrate addition. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 2 GENERAL INFORMATION GENERAL INFORMATION 3. PRECAUTIONS Please read these instructions carefully prior to beginning the assay. All kit components have been formulated and quality control tested to function successfully as a kit. Modifications to the kit components or procedures may result in loss of performance. 4. STORAGE AND STABILITY Store kit at 2-8ºC immediately upon receipt. Refer to list of materials supplied for storage conditions of individual components. Observe the storage conditions for individual prepared components in the Reagent and Standard Preparation sections. 5. MATERIALS SUPPLIED 10X Mouse Myoglobin Capture Antibody 600 µL Storage Condition (Before Preparation) +4ºC 10X Mouse Myoglobin Detector Antibody Mouse Myoglobin Lyophilized Recombinant Protein Antibody Diluent 4BI 600 µL +4ºC 2 Vials +4ºC 6 mL +4ºC 10X Wash Buffer PT 20 mL +4ºC 5X Cell Extraction Buffer PTR 10 mL +4ºC 50X Cell Extraction Enhancer Solution 1 mL +4ºC TMB Substrate 12 mL +4ºC Stop Solution 12 mL +4ºC Sample Diluent NS Pre-Coated 96 Well Microplate (12 x 8 well strips) Plate Seal 50 mL +4ºC 96 Wells +4ºC 1 +4ºC Item ab210965 Mouse Myoglobin SimpleStep ELISA Kit Amount 3 GENERAL INFORMATION 6. MATERIALS REQUIRED, NOT SUPPLIED These materials are not included in the kit, but will be required to successfully utilize this assay: Microplate reader capable of measuring absorbance at 450 or 600 nm. Method for determining protein concentration (BCA assay recommended). Deionized water. Multi- and single-channel pipettes. Tubes for standard dilution. Plate shaker for all incubation steps. Optional: Phenylmethylsulfonyl Fluoride (PMSF) (or other protease inhibitors). 7. LIMITATIONS Assay kit intended for research use only. Not for use in diagnostic procedures. Do not mix or substitute reagents or materials from other kit lots or vendors. Kits are QC tested as a set of components and performance cannot be guaranteed if utilized separately or substituted. 8. TECHNICAL HINTS Samples generating values higher than the highest standard should be further diluted in the appropriate sample dilution buffers. Avoid foaming components. Avoid cross contamination of samples or reagents by changing tips between sample, standard and reagent additions. Ensure plates are properly sealed or covered during incubation steps. or bubbles when ab210965 Mouse Myoglobin SimpleStep ELISA Kit mixing or reconstituting 4 GENERAL INFORMATION Complete removal of all solutions and buffers during wash steps is necessary to minimize background. As a guide, typical ranges of sample concentration for commonly used sample types are shown below in Sample Preparation (section 11). All samples should be mixed thoroughly and gently. Avoid multiple freeze/thaw of samples. Incubate ELISA plates on a plate shaker during all incubation steps. When generating positive control samples, it is advisable to change pipette tips after each step. The provided 5X Cell Extraction Buffer contains phosphatase inhibitors and protease inhibitor aprotinin. Additional protease inhibitors can be added if required. The provided Antibody Diluents and Sample Diluents contain protease inhibitor aprotinin. Additional protease inhibitors can be added if required. The provided 50X Cell Extraction Enhancer Solution may precipitate when stored at + 4ºC. To dissolve, warm briefly at + 37ºC and mix gently. The 50X Cell Extraction Enhancer Solution can be stored at room temperature to avoid precipitation. To avoid high background always add samples or standards to the well before the addition of the antibody cocktail. This kit is sold based on number of tests. A ‘test’ simply refers to a single assay well. The number of wells that contain sample, control or standard will vary by product. Review the protocol completely to confirm this kit meets your requirements. Please contact our Technical Support staff with any questions. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 5 ASSAY PREPARATION ASSAY PREPARATION 9. REAGENT PREPARATION Equilibrate all reagents to room temperature (18-25°C) prior to use. The kit contains enough reagents for 96 wells. The sample volumes below are sufficient for 48 wells (6 x 8-well strips); adjust volumes as needed for the number of strips in your experiment. Prepare only as much reagent as is needed on the day of the experiment. Capture and Detector Antibodies have only been tested for stability in the provided 10X formulations. 9.1 1X Cell Extraction Buffer PTR (For cell and tissue extracts only) Prepare 1X Cell Extraction Buffer PTR by diluting 5X Cell Extraction Buffer PTR and 50X Cell Extraction Enhancer Solution to 1X with deionized water. To make 10 mL 1X Cell Extraction Buffer PTR combine 8 mL deionized water and 2 mL 5X Cell Extraction Buffer PTR. Mix thoroughly and gently. If required protease inhibitors can be added. 9.2 1X Wash Buffer PT Prepare 1X Wash Buffer PT by diluting 10X Wash Buffer PT with deionized water. To make 50 mL 1X Wash Buffer PT combine 5 mL 10X Wash Buffer PT with 45 mL deionized water. Mix thoroughly and gently. 9.3 Antibody Cocktail Prepare Antibody Cocktail by diluting the capture and detector antibodies in Antibody Diluent. To make 3 mL of the Antibody Cocktail combine 300 µL 10X Capture Antibody and 300 µL 10X Detector Antibody with 2.4 mL Antibody Diluent. Mix thoroughly and gently. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 6 ASSAY PREPARATION 10. STANDARD PREPARATION Prepare serially diluted standards immediately prior to use. Always prepare a fresh set of positive controls for every use. The following section describes the preparation of a standard curve for duplicate measurements (recommended). 10.1 For serum, plasma and cell culture supernatant samples follow these instructions: 10.1.1 Reconstitute the Myoglobin standard sample by adding 100 µL water. Mix thoroughly and gently. Hold at room temperature for 10 minutes and mix gently. This is the 50,000 pg/mL Stock Standard Solution. 10.1.2 Label eight tubes, Standards 1– 8. 10.1.3 Add 475 μL Sample Diluent NS into tube number 1 and 150 μL of Sample Diluent NS into numbers 2-8. 10.1.4 Use the Stock Standard to prepare the following dilution series. Standard #8 contains no protein and is the Blank control: 25 µL 150 µL 150 µL 150 µL 150 µL 150 µL 150 µL µ 50,000 pg/mL 2,500 pg/mL XX µL µL µL XX µL µ µ µ µ 625 1,250 312.5 156.25 pg/mL pg/mL pg/mL pg/mL ab210965 Mouse Myoglobin SimpleStep ELISA Kit µ 0 78.12 39.06 pg/mL pg/mL pg/mL 7 ASSAY PREPARATION 10.2 For cell and tissue extract samples follow these instructions: 10.2.1 Reconstitute the Myoglobin standard sample by adding 100 µL water. Mix thoroughly and gently. Hold at room temperature for 10 minutes and mix gently. This is the 50,000 pg/mL Stock Standard Solution. 10.2.2 Label eight tubes, Standards 1– 8. 10.2.3 Add 490 μL 1X Cell Extraction Buffer PTR into tube number 1 and 150 μL of 1X Cell Extraction Buffer PTR into numbers 2-8 10.2.4 Use the Stock Standard to prepare the following dilution series. Standard #8 contains no protein and is the Blank control: 10 µL 150 µL 150 µL 150 µL 150 µL 150 µL 150 µL µ µ µ µ L µ µ 50,000 pg/mL 1,000 pg/mL 250 125 500 62.5 pg/mL pg/mL pg/mL pg/mL ab210965 Mouse Myoglobin SimpleStep ELISA Kit 0 31.25 15.62 pg/mL pg/mL pg/mL 8 ASSAY PREPARATION 11. SAMPLE PREPARATION TYPICAL SAMPLE DYNAMIC RANGE Sample Type Range Mouse Plasma - Heparin 1% - 20% Mouse Plasma - EDTA 1:64 – 1:4 Mouse Plasma - Citrate 2% – 38% Mouse Serum 1:128 – 1:8 Heart Supernatant 1:50,00 – 1:1600 C2C12 Cell Extract 8 – 125 μg/mL Skeletal Muscle Extract 20 – 300 ng/mL 11.1 Plasma Collect plasma using citrate, EDTA or heparin. Centrifuge samples at 2,000 x g for 10 minutes. Dilute samples into Sample Diluent NS and assay. Store un-diluted plasma samples at -20ºC or below for up to 3 months. Avoid repeated freeze-thaw cycles. 11.2 Serum Samples should be collected into a serum separator tube. After clot formation, centrifuge samples at 2,000 x g for 10 minutes and collect serum. Dilute samples into Sample Diluent NS and assay. Store un-diluted serum at -20ºC or below. Avoid repeated freeze-thaw cycles. 11.3 Cell Culture Supernatants Centrifuge cell culture media at 2,000 x g for 10 minutes to remove debris. Collect supernatants and assay. Or dilute samples into Sample Diluent NS and assay. Store un-diluted samples at -20°C or below. Avoid repeated freeze-thaw cycles. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 9 ASSAY PREPARATION 11.4 Preparation of extracts from cell pellets 11.4.1 Collect non-adherent cells by centrifugation or scrape to collect adherent cells from the culture flask. Typical centrifugation conditions for cells are 500 x g for 5 minutes at 4ºC. 11.4.2 Rinse cells twice with PBS. 11.4.3 Solubilize pellet at 2x107 cell/mL in chilled 1X Cell Extraction Buffer PTR. 11.4.4 Incubate on ice for 20 minutes. 11.4.5 Centrifuge at 18,000 x g for 20 minutes at 4°C. 11.4.6 Transfer the supernatants into clean tubes and discard the pellets. 11.4.7 Assay samples immediately or aliquot and store at -80°C. The sample protein concentration in the extract may be quantified using a protein assay. 11.4.8 Dilute samples to desired concentration in 1X Cell Extraction Buffer PTR. 11.5 Preparation of extracts from adherent cells by direct lysis (alternative protocol) 11.5.1 Remove growth media and rinse adherent cells 2 times in PBS. 11.5.2 Solubilize the cells by addition of chilled 1X Cell Extraction Buffer PTR directly to the plate (use 750 µL - 1.5 mL 1X Cell Extraction Buffer PTR per confluent 15 cm diameter plate). 11.5.3 Scrape the cells into a microfuge tube and incubate the lysate on ice for 15 minutes. 11.5.4 Centrifuge at 18,000 x g for 20 minutes at 4°C. 11.5.5 Transfer the supernatants into clean tubes and discard the pellets. 11.5.6 Assay samples immediately or aliquot and store at -80°C. The sample protein concentration in the extract may be quantified using a protein assay. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 10 ASSAY PREPARATION 11.5.7 Dilute samples to desired concentration in 1X Cell Extraction Buffer PTR. 11.6 Preparation of extracts from tissue homogenates 11.6.1 Tissue lysates are typically prepared by homogenization of tissue that is first minced and thoroughly rinsed in PBS to remove blood (dounce homogenizer recommended). 11.6.2 Homogenize 100 to 200 mg of wet tissue in 500 µL – 1 mL of chilled 1X Cell Extraction Buffer PTR. For lower amounts of tissue adjust volumes accordingly. 11.6.3 Incubate on ice for 20 minutes. 11.6.4 Centrifuge at 18,000 x g for 20 minutes at 4°C. 11.6.5 Transfer the supernatants into clean tubes and discard the pellets. 11.6.6 Assay samples immediately or aliquot and store at -80°C. The sample protein concentration in the extract may be quantified using a protein assay. 11.6.7 Dilute samples to desired concentration in 1X Cell Extraction Buffer PTR. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 11 ASSAY PREPARATION 12. PLATE PREPARATION The 96 well plate strips included with this kit are supplied ready to use. It is not necessary to rinse the plate prior to adding reagents. Unused plate strips should be immediately returned to the foil pouch containing the desiccant pack, resealed and stored at 4°C. For each assay performed, a minimum of two wells must be used as the zero control. For statistical reasons, we recommend each sample should be assayed with a minimum of two replicates (duplicates). Differences in well absorbance or “edge effects” have not been observed with this assay. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 12 ASSAY PROCEDURE ASSAY PROCEDURE 13. ASSAY PROCEDURE Equilibrate all materials and prepared reagents to room temperature prior to use. It is recommended to assay all standards, controls and samples in duplicate. 13.1. Prepare all reagents, working standards, and samples as directed in the previous sections. 13.2. Remove excess microplate strips from the plate frame, return them to the foil pouch containing the desiccant pack, reseal and return to 4ºC storage. 13.3. Add 50 µL of all sample or standard to appropriate wells. 13.4. Add 50 µL of the Antibody Cocktail to each well. 13.5. Seal the plate and incubate for 1 hour at room temperature on a plate shaker set to 400 rpm. 13.6. Wash each well with 3 x 350 µL 1X Wash Buffer PT. Wash by aspirating or decanting from wells then dispensing 350 µL 1X Wash Buffer PT into each well. Complete removal of liquid at each step is essential for good performance. After the last wash invert the plate and blot it against clean paper towels to remove excess liquid. 13.7. Add 100 µL of TMB Substrate to each well and incubate for 10 minutes in the dark on a plate shaker set to 400 rpm. 13.8. Add 100 µL of Stop Solution to each well. Shake plate on a plate shaker for 1 minute to mix. Record the OD at 450 nm. This is an endpoint reading. Alternative to 13.7 – 13.8: Instead of the endpoint reading at 450 nm, record the development of TMB Substrate kinetically. Immediately after addition of TMB Development Solution begin recording the blue color development with elapsed time in the microplate reader prepared with the following settings: ab210965 Mouse Myoglobin SimpleStep ELISA Kit 13 ASSAY PROCEDURE Mode: Kinetic Wavelength: 600 nm Time: up to 15 min Interval: 20 sec - 1 min Shaking: Shake between readings Note that an endpoint reading can also be recorded at the completion of the kinetic read by adding 100 µL Stop Solution to each well and recording the OD at 450 nm. 13.9. Analyze the data as described below. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 14 DATA ANALYSIS DATA ANALYSIS 14. CALCULATIONS 14.1 Calculate the average absorbance value for the blank control (zero) standards. Subtract the average blank control standard absorbance value from all other absorbance values. 14.2 Create a standard curve by plotting the average blank control subtracted absorbance value for each standard concentration (y-axis) against the target protein concentration (x-axis) of the standard. Use graphing software to draw the best smooth curve through these points to construct the standard curve. Note: Most microplate reader software or graphing software will plot these values and fit a curve to the data. A four parameter curve fit (4PL) is often the best choice; however, other algorithms (e.g. linear, semi-log, log/log, 4 parameter logistic) can also be tested to determine if it provides a better curve fit to the standard values. 14.3 Determine the concentration of the target protein in the sample by interpolating the blank control subtracted absorbance values against the standard curve. Multiply the resulting value by the appropriate sample dilution factor, if used, to obtain the concentration of target protein in the sample. 14.4 Samples generating absorbance values greater than that of the highest standard should be further diluted and reanalyzed. Similarly, samples which measure at an absorbance values less than that of the lowest standard should be retested in a less dilute form. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 15 DATA ANALYSIS 15. TYPICAL DATA TYPICAL STANDARD CURVE – Data provided for demonstration purposes only. A new standard curve must be generated for each assay performed. Standard Curve Measurements Conc. O.D. 450 nm Mean (pg/mL) 1 2 O.D. 0 0.092 0.095 0.094 39.06 0.176 0.153 0.165 78.12 0.226 0.188 0.207 156.25 0.284 0.296 0.290 312.5 0.510 0.525 0.518 625 0.845 0.979 0.912 1,250 1.734 1.980 1.857 2,500 3.427 3.615 3.521 Figure 1. Example of mouse Myoglobin standard curve in Sample Diluent NS. The Myoglobin standard curve was prepared as described in Section 10. Raw data values are shown in the table. Background-subtracted data values (mean +/- SD) are graphed. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 16 DATA ANALYSIS Standard Curve Measurements Conc. O.D. 450 nm Mean (pg/mL) 1 2 O.D. 0 0.056 0.060 0.058 15.62 0.103 0.107 0.105 31.25 0.141 0.152 0.146 62.5 0.209 0.231 0.220 125 0.372 0.396 0.384 250 0.731 0.764 0.747 500 1.470 1.507 1.489 1,000 3.049 3.112 3.081 Figure 2. Example of mouse Myoglobin standard curve in 1X Cell Extraction Buffer PTR. The Myoglobin standard curve was prepared as described in Section 10. Raw data values are shown in the table. Background-subtracted data values (mean +/- SD) are graphed. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 17 DATA ANALYSIS 16. TYPICAL SAMPLE VALUES SENSITIVITY – The calculated minimal detectable dose (MDD) is determined by calculating the mean of zero standard replicates and adding 2 standard deviations then extrapolating the corresponding concentration. The MDD is dependent on the Sample Diluent buffer used: Sample Diluent Buffer Sample Diluent NS 1X Cell Extraction Buffer PTR n= Minimal Detectable Dose 24 24 10.6 pg/mL 9.4 pg/mL RECOVERY – Three concentrations of Myoglobin were spiked in duplicate to the indicated biological matrix to evaluate signal recovery in the working range of the assay. Sample Type Mouse Serum Mouse Plasma - Citrate Mouse Plasma - Heparin Mouse Plasma - EDTA Mouse Heart Supernatant Mouse Skeletal Muscle Extract Average % Recovery 88 112 105 100 115 112 ab210965 Mouse Myoglobin SimpleStep ELISA Kit Range (%) 76-99 100-120 100-113 95-106 110-123 108-119 18 DATA ANALYSIS LINEARITY OF DILUTION – Linearity of dilution is determined based on interpolated values from the standard curve. Linearity of dilution defines a sample concentration interval in which interpolated target concentrations are directly proportional to sample dilution. Native Myoglobin was measured in the following biological samples in a 2-fold dilution series. Sample dilutions are made in Sample Diluent NS. 37.5% 25% 20% 12.5% 1:1600 Dilution Mouse Mouse Mouse Interpolated value Mouse Mouse Heart Plasma Plasma Plasma Factor Serum Supernatant (Citrate) (EDTA) (Heparin) 2,757 pg/mL 896 1,452 2,226 1,260 Undiluted 100 % Expected value 100 100 100 100 1,296 pg/mL 386 689 965 673 2 94 % Expected value 86 95 87 107 596 pg/mL 200 341 529 298 4 86 % Expected value 89 94 95 94 281 pg/mL 108 162 211 149 8 82 % Expected value 96 89 76 95 150 pg/mL 60 75 109 85 16 87 % Expected value 109 83 78 108 ab210965 Mouse Myoglobin SimpleStep ELISA Kit 19 DATA ANALYSIS Native Myoglobin was measured in the following biological samples in a 2-fold dilution series. Sample dilutions are made in 1X Cell Extraction Buffer PTR Dilution Factor Undiluted 2 4 8 16 Interpolated value pg/mL % Expected value pg/mL % Expected value pg/mL % Expected value pg/mL % Expected value pg/mL % Expected value 300 ng/mL Mouse 125 μg/mL Skeletal Muscle C2C12 Extract Extract 1044 687 100 100 559 353 107 103 263 168 101 98 136 84 105 97 69 38 106 88 PRECISION – Mean coefficient of variations of interpolated values of Myoglobin in 3 concentrations of mouse serum within the working range of the assay. n= CV (%) IntraAssay 8 6.1 ab210965 Mouse Myoglobin SimpleStep ELISA Kit InterAssay 3 4.8 20 DATA ANALYSIS Figure 3. Interpolated concentrations of native Myoglobin in mouse serum, plasma and cell culture supernatant samples. The concentrations of Myoglobin were measured in duplicates, interpolated from the Myoglobin standard curves and corrected for sample dilution. Undiluted samples are as follows: serum 12.5%, plasma (citrate) 37.5%, plasma (heparin) 20%, plasma (EDTA) 25% and heart supernatant 1:1600. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean Myoglobin concentration was determined to be 6.87 ng/mL in serum, 3.57 ng/mL in plasma (citrate), 6.35 ng/mL in plasma (heparin), 7.76 ng/mL in plasma (EDTA) and 4,187 ng/mL in heart supernatant. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 21 DATA ANALYSIS Figure 4. Interpolated concentrations of native Myoglobin in mouse skeletal muscle based on a 300 ng/mL extract load and C2C12 extract based on a 125 μg/mL extract load. The concentrations of Myoglobin were measured in duplicate and interpolated from the Myoglobin standard curve and corrected for sample dilution. The interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean Myoglobin concentration was determined to be 1.08 ng/mL in skeletal muscle extract and 0.67 ng/mL in C2C12 extract. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 22 DATA ANALYSIS 17. ASSAY SPECIFICITY This kit recognizes both native and recombinant mouse Myoglobin protein in serum, plasma, and cell culture supernatant, cell and tissue extract samples only. CROSS REACTIVITY Recombinant human Myoglobin was prepared at 50 ng/mL and 1 ng/mL and assayed for cross reactivity. No cross-reactivity was observed. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 23 DATA ANALYSIS 18. SPECIES REACTIVITY This kit recognizes mouse Myoglobin protein. Other species reactivity was determined by measuring 15% serum samples of various species, interpolating the protein concentrations from the mouse standard curve, and expressing the interpolated concentrations as a percentage of the protein concentration in mouse serum assayed at the same dilution. Reactivity < 3% was determined for the following species: Human Cow Please contact our Technical Support team for more information. ab210965 Mouse Myoglobin SimpleStep ELISA Kit 24 RESOURCES RESOURCES 19. TROUBLESHOOTING Problem Cause Solution Inaccurate Pipetting Check pipettes Improper standard dilution Prior to opening, briefly spin the stock standard tube and dissolve the powder thoroughly by gentle mixing Incubation times too brief Ensure sufficient incubation times; increase to 2 or 3 hour standard/sample incubation Inadequate reagent volumes or improper dilution Check pipettes and ensure correct preparation Incubation times with TMB too brief Ensure sufficient incubation time until blue color develops prior addition of Stop solution Plate is insufficiently washed Review manual for proper wash technique. If using a plate washer, check all ports for obstructions. Contaminated wash buffer Prepare fresh wash buffer Low sensitivity Improper storage of the ELISA kit Store your reconstituted standards at -80°C, all other assay components 4°C. Keep TMB substrate solution protected from light. Precipitate in Diluent Precipitation and/or coagulation of components within the Diluent. Precipitate can be removed by gently warming the Diluent to 37ºC. Poor standard curve Low Signal Large CV ab210965 Mouse Myoglobin SimpleStep ELISA Kit 25 RESOURCES 20. NOTES ab210965 Mouse Myoglobin SimpleStep ELISA Kit 26 UK, EU and ROW Email: technical@abcam.com | Tel: +44-(0)1223-696000 Austria Email: wissenschaftlicherdienst@abcam.com | Tel: 019-288-259 France Email: supportscientifique@abcam.com | Tel: 01-46-94-62-96 Germany Email: wissenschaftlicherdienst@abcam.com | Tel: 030-896-779-154 Spain Email: soportecientifico@abcam.com | Tel: 911-146-554 Switzerland Email: technical@abcam.com Tel (Deutsch): 0435-016-424 | Tel (Français): 0615-000-530 US and Latin America Email: us.technical@abcam.com | Tel: 888-77-ABCAM (22226) Canada Email: ca.technical@abcam.com | Tel: 877-749-8807 China and Asia Pacific Email: hk.technical@abcam.com | Tel: 108008523689 (中國聯通) Japan Email: technical@abcam.co.jp | Tel: +81-(0)3-6231-0940 www.abcam.com | www.abcam.cn | www.abcam.co.jp Copyright © 2016 Abcam, All Rights Reserved. The Abcam logo is a registered trademark. All information / detail is correct at time of going to print. Discover more at www.abcam.com