WavePro LTG Lighting Busway GE GE is a diversified organization covering a myriad of market segments, including infrastructure, finance and media. From energy, water, transportation and health to access to money and information, GE serves customers in more than 100 countries and employs more than 300,000 people worldwide. The company traces its beginnings from Thomas A. Edison, who established the Edison Electric Light Company in 1878. In 1892, a merger of Edison General Electric Company and Thomson-Houston Electric Company created the General Electric Company. GE is the only company listed in the Dow Jones Industrial Index today that was also included in the original index in 1896. Industrial Solutions GE Industrial Solutions, a division of GE Energy, is a global leading provider in power distribution, offering a wide range of products which includes medium and low voltage power distribution equipments and components, and motor & control systems that are safe, reliable and offer high performance. Its innovative solutions can improve energy efficiency and environmental impact in power plants, power grids, oil & gas, mining, data center, overseas EPC, industrial manufacturing, rail transportation, commercial buildings, residential houses, renewable energy and many other industries. GE is one of the worldwide partners of the Olympic Games. In 2008, GE assisted Beijing with this tremendous event, which was unprecedented in scale and first-class in its use of science and technology, offering a series of innovative solutions and products for around 400 Olympic infrastructure projects, covering fields in electricity distribution, lighting, security, water processing, benefiting some 37 Olympic venues and 168 commercial buildings. GE also brought its experiences to the 2010 Expo in Shanghai, Asia Games in Guangzhou, Vancouver Olympic Games and will continue through to the London 2012 Olympic Games. 2010 World's Most Innovative Companies 2011 World’s Most Admired Companies 2009 World’s Most Respected Companies 2011 Best Global Brand 2008 World’s Most Respected Companies 2007 World’s Best R&D Companies Quick Index 1 2 3 4 System Overview Features & Advantages Certification & Standard Electrical Characteristics Basic Electrical Characteristics Electrical Characteristics for Conductor Effect of Ambient Temperature during Application Weight of Busway 5 Components Features Straight Length 6 Feed Unit End Cover Flexible Elbow Specifications & Data Straight Length Feed Unit Tap-off Unit Flexible Elbow 8Accessories 9 Fixing Bracket Snap Clamp Cable Clamp Fixing Clamp Suspension Bracket Mouse Hook Application & Installation Straight Length & Feed Unit Lighting Busway Other Installation Examples Start Notice Installation Requirements 11 12 14 4 Ordering Information Frequently Used Catalogue Numbers Catalogue Numbering System System Overview WavePro LTG is a modularized busway to distribute electric power for lighting system by simple plugging connection, which is able to provide sufficient power branches as necessary and protection while extending mechanical support for the weight of lighting fixture underneath. WavePro LTG is constructed with a high-quality extruded aluminium alloy housing having characteristics such as, light in weight, compact in size, offering high mechanical strength. WavePro LTG utilizes high-quality copper as conductors and Al housing as ground; copper conductors are enclosed with a environmental friendly low-smoke, halogen-free and flame retardant insulation. WavePro LTG can be customized with multiple-number of outlets according to actual application offering flexibility for installation and power distribution to be adopted in complex situations. WavePro LTG can be installed vertically as well as horizontally onto the truss, ceiling, wall and floor, this makes it a preferred choice to energize middle to large commercial lighting and places with low load situations such as: airports, subway stations, workshops, exhibition halls, warehouses, shopping malls. WavePro LTG mainly consists of straight lengths, feed units, terminal units, flexible elbows, tap-off units and accessories such as cable clamps, various fixing brackets. All units and accessories are standardized, modularized during designing and producing in order to ensure easier installation and application. 1 WavePro LTG Features & Advantages Compact and flexible • • WavePro LTG lighting busway , will save space while compared to cables due to its compact housing size of 48mm×32mm Various functional units, components can be used at any corner, to bypass obstacles, as well as change height of busway routing by using flexible elbows, which offers flexibility for adopting routing to any construction space Safe and reliable plug unit • • • 2 WavePro LTG plug unit uses flame-retardant ABS plastic body and has features such as compact and light weight design, offering high strength in addition to extended life and excellent insulation Silver-plated spring stabs provide reliable electrical connection; longer grounding pin design makes contact first but leaves last when compared to phase pins offering grounding protection Clamps adjacent to plug unit can lock onto busway trunk and ensure reliable electrical contact with enhanced degree of protection Aluminium alloy housing • • • WavePro LTG uses complete aluminium alloy housing throughout the length, offering features such as lighter weight, higher strength, and protection degree upto IP54 WavePro LTG housing has excellent anti-corrosion properties and has grounding capacity at least 50% equivalent to phase conductors WavePro LTG comprises materials which minimize magnetic hysteresis loss, enhancing efficiency of energy transfer and reducing the voltage drop of the system Safe insulating material • • WavePro LTG Lighting busways use environment friendly and low smoke halogen-free flame retardant materials Supporting insulation parts have been successfully type tesed by glow wire test at 9600C; Non-supporting insulation parts have been successfully type tested by glow wire test at 6500C Easy installation • • Interconnection between trunk units, feed units, terminal units, flexible elbows, joints can be carried out by "insertion" action for achieving proper installation whilst ensuring satisfactory electrical and mechanical performance There is a feature to prevent wrong insertion, design and construction of adjacent units is done in such a way that they can only be connected with each other in proper way as per phase orientation, configuration declared in ordering information Certification & Standard • EN60439-2: 2000 + A1: 2005 • IEC60439-2: 2000 + A1: 2005 3 Electrical Characteristics Basic Electrical Characteristics Rated Current (A) Rated Voltage (V AC) Rated Insulation Voltage (V AC) Frequency (Hz) Short Cicuit Withstand Current (t=1s) (kA) 25 40 2×25 2×40 415 415 415 415 690 690 690 690 50/60 50/60 50/60 50/60 0.69 0.94 0.69 0.94 Degree of Protection Number of Wire Material of Conductor Cross Section of Conductor (L1, L2, L3, N) (mm2) IP40 / IP42 / IP43 / IP54 4 4 4 4 Cu Cu Cu Cu 4 6 2×4 2×6 Tab. 4-1 Electrical Characteristics for Conductor Degree of Current A 25 40 Single Phase Conductor Protective Conductor Voltage Drop Voltage drop of single phase Mean resistance at an ambient Mean resistance at an ambient temperature of 200C (The three-phases network voltage drop is obtained by multiplying 0.866) temperature of 200C (R20) V/100m/A 10-6Ω/m 10-6Ω/m Power factor Power factor Power factor Power factor Power factor CosΦ=0.6 CosΦ=0.7 CosΦ=0.8 CosΦ=0.9 CosΦ=1.0 4609.3 301.3 0.50 0.58 0.66 0.73 0.80 3072.8 301.3 0.34 0.39 0.44 0.49 0.53 Tab. 4-2 Effect of Ambient Temperature during Application Ambient Temperature (0C) 35 40 45 50 55 60 Factor 1 0.95 0.90 0.85 0.80 0.75 Tab. 4-3 Within the ambient temperature of 350C, WavePro LTG Lighting busway can continuously operate at rated current while the maximum housing temperature rise will not exceed 55K. If the busway is continuously operated at higher ambient temperature, it should be derated first, i.e. the busway current-carrying capacity=rated current × de-rating factor. (As shown in Tab. 4-3). Weight of Busway Type 25A 40 A 25 A +40 A 25 A ×2 40 A ×2 Tab. 4-4 4 Weight (kg/m) 0.9 1.0 1.2 1.1 1.3 Components Features Straight Length Straight Length plays important role in lighting busway and they are functional with just a simple direct "head" to "tail" insertion. Fig. 5-1 • Aluminium alloy housing (size of 48×32mm), acts as PE, with features such as good mechanical strength, lesser weight and it also improves aesthetical appearance • Standard straight trunk is as long as 2m or 3m, while outlets' spacing is 0.5m or 1 meter. Non-standard lengths can be customized in consultation with our engineers • Degree of Protection available up to IP54 • Fire retardant insulations are in line with the performance of GB and IEC standards (IEC 60695-2-1) -Supportive insulating parts are able to withstand the pressure of glow wire at 9600C -Non-supportive insulating parts are able to withstand the pressure of glow wire at 6500C Span of Installation (m) 2.0 2.5 3.0 Concentrated Load (kg) 18 14 12 Average Load (kg) 27 24 18 Tab. 5-1 Feed Unit Power supply to the lighting busway originates from Feed Unit; the installation between a feed unit and a straight length is similar to two straight lengths connecting each other, inserting head into housing and pressing buttons in position to lock. Fig. 5-2 End Cover End cover (or terminal unit) completes the end of the lighting busway. The installation is similar to straight length. Fig. 5-3 Flexible Elbow Fig. 5-4 Flexible elbow consists of two feed units which are connected through a flexible tube. You can change the direction or height of the busway, or bypassing an obstacle by using the flexible length, the installation method is same as joining two straight length. There are 0.5m, 1m in two standard lengths, while the non-standard lengths can be customized. 5 Specifications & Data Straight Length Left Right Current entry Joint groove downward 2m Single-circuit, dual-circuit dimension & layout of sockets 800 700 N L3 L2 L1 2 2m Dual-circuit 500 800 48 32 700 N L3 L2 L1 48 500 Unit: mm N L3 L2 L1 1 2m Single-circuit 32 2000 800 800 700 N L3 L2 L1 3 3m Single-circuit 500 800 800 900 32 N L3 L2 L1 4 3m Dual-circuit 500 800 800 48 500 500 900 N L3 L2 L1 48 700 32 3000 900 Straight length • For the single-circuit busway, the unit with standard length of 2m has maximum 2 sockets, while the 3m has maximum 3 sockets • For the dual-circuit busway, the unit with standard length of 2m has maximum 4 (2 for each side) sockets, while the 3m has maximum 6 sockets (3 for each side) • More sockets are available for customized applications 6 800 800 Num Cat. # 1 2 3 4 WPLTGBT2E0IP54-20 WPLTGBF2F1IP54-20 WPLTGBT3E0IP54-30 WPLTGBT3T3IP54-30 500 Number of Outlet Left 2 Left2Right1 Left3 Left3Right3 Rated Current (A) 25 40×2 25 25×2 Tab. 6-1 Please refer to Catalogue Numbering System for more. Degree of Measures Protection (m) 2 2 IP54 3 3 Feed Unit • Feed unit has insulation shield (dual-circuit line busway has separate two circuits) • Three sides of the feed unit will have sockets and knock off holes at the right, left and end side • Special sealed connector is used to connect the flexible length • Used to connect 2.5mm² -10mm² cable Cat. # Type WPLTGFF0E0IP54-20 WPLTGFF0F0IP54-20 WPLTGFT0E0IP54-30 WPLTGFT0T0IP54-30 Feed Unit Feed Unit Feed Unit Feed Unit Rated Current (A) 40 40×2 25 25×2 Degree of Protection IP54 Pipe length (m) 2 2 3 3 Tab. 7-1 Please refer to Catalogue Numbering System for more. Unit: mm 145 135 ø32 120 130 Tap-off Unit (Plug) • • • Tap-off unit has 3 wires. It can be converted into L1, N, PE or L2, N, PE or L3, N, PE Meets IEC60332-1 Flammability Property Purchaser can specify cable length and type Cat.# Type WPLTGP10L1IP54-10 WPLTGP16L2IP54-20 Plug Plug Degree of Current (A) 10 16 Phase Degree of Protection L1 L2 IP54 Cable length (m) 1 2 Tab. 7-2 Please refer to Catalogue Numbering System for more. Unit: mm 48 57 24 Flexible Elbow Unit: mm 140 B B is 0.5m typically. Cat.# WPLTGEE0T0IP54-05 WPLTGET0E0IP54-10 WPLTGEE0F0IP54-05 WPLTGEF0E0IP54-10 Number of Outlets 0 0 0 0 Rated Current (A) 25 25 40 40 Degree of Protection IP54 Pipe length (m) 0.5 1 0.5 1 Tab. 7-3 Please refer to catalogue numbering system for further details. 7 Accessories 2 3 6 1 Code 5 Description 1 Fixing Bracket 2 Snap Clamp 3 Cable Clamp 4 Fixing Clamp 5 Suspension Bracket 6 Mouse Hook 4 1 Fixing Bracket 4 Fixing Clamp Fixing bracket is used to suspend the lighting busway and fixtures with cable or chain, it can also be used to support the joint area to improve mechanical strength. Fixing clamp is used to fix and support the busway when the lighting busway is installed under the floor. 69 Unit: mm 85 46 Unit: mm 20 15 85 37 200 Cat.#: WPLTGAHGB Cat.#: WPLTGAFXS 2 Snap Clamp 5 Suspension Bracket Snap clamp is used to suspend the straight length or for the installation of the lighting fixtures (balanced load). It can be used to fix the selected straight length. Suspension bracket is used to suspend and fix the busway when the lighting busway is installed under the ceiling. 20 Unit: mm 112 79 Unit: mm 25 30 39 Cat.#: WPLTGACLP Cat.#: WPLTGAFXB 3 Cable Clamp 6 Mouse Hook Cable can be fixed on a straight length by using cable clamp to simplify the line strike and save space. Mouse hook is used in conjunction with the fix bracket to fix the lighting busway on the buildings. 40 Unit: mm Unit: mm 157 28 10 39 Cat.#: WPLTGACBC Cat.#: WPLTGAMHK M6 8 Application & Installation Straight Length & Feed Unit The installation of two straight lengths is illustrated as below. Each length of the system plugs into the adjacent length with just a push, for electrical and mechanical connection. Kindly ensure the joint is pushed fully together leaving no gap. Fig. 9-1 Fig. 9-2 The installation of feed unit and straight length is the same as the installation of two straight lengths. The Feed unit plugs into the adjacent length with a push, ensuring electrical and mechanical connection. Kindly ensure the joint is pushed fully together leaving no gap. Lighting Busway Typical Installation The lighting busway will be fixed on the construction. Appropriate support accessories are to be selected for the installation. Fig. 9-3 shows the lighting busway's installation on the beam. Fig. 9-3 Other Installation Examples 1. Suspension Installation Fig. 9-4 2. Side Installation Fig. 9-5 Please refer to the installation instructions for details. 9 Start Notice Determine how the Busway is to be installed so as to ensure correct phase sequence throughout the system. The Busway housing consists of two parts: "Π" part and "" part (Fig. 10-1). Correct installation should be in such a way that it meets claimed IP42/43/IP54 protective grade: the hatch of the "Π" part should be oriented to downward (Fig 10-1), the outlet (if have) at side of housing. Fig. 10-1 Installation Requirements Please select appropriate accessories in accordance with the actual situation and installation drawings and ensure the installation of the lighting busway, the mounting brackets and other accessories is in line with the bus strike. For Installation space please refer the following • The installation distance between any straight lengths is not more than 3 m, the specific spacing requirements of installation should be illustrated in the installation drawings in accordance with the conditions and circumstances at the site. (For spacing and load-bearing capacity of installation, please see the table 10.1) • The mounting brackets should be set up at both ends of the joint, while the maximum spacing should not exceed 1 m 10 Span of Installation (m) Concentrated Load (kg) Average Load (kg) 2.0 2.5 3.0 18 14 12 27 24 18 Tab. 10-1 Ordering Information Lighting Busway Technical Agreement List Project Name: ________________________________ Project No: _________________________ Product Type: ________________________________ WavePro LTG: _______________________ Quantity: ____________________________________ Connecting Drawing: _________________ Busway Arrangement Drawing: _____________________ BOM: ______________________________ Item WavePro LTG Busway Technical Data Standard GB 7251.1&2-2006 IEC-60439-1&2 Service Condition Relative humidity not exceed 90% at +200C Altitude (m) <2000 0 Max. Ambient temperature C 0 40 Min. Ambient temperature C -5 Average Ambient temperature0C 35 Power Source Rated Voltage (V) 415 Rated Frequency (Hz) 50 Phase 3 60 Busway Utility Data Rated Current (A) 25 40 20×2 Number of Phase 3P5W L1,L2,L3,N100%,PE50% (housing grounding) Protection Degree IP40 IP42 Short-time Withstand Current (kA/1s) 0.69 (25A circuit) 0.94 (40A circuit) Phase Sequence L1,L2,L3, N,PE(From Top to Bottom) Other Phase Color: GB Standard IP43 40×2 25+40 IP54 IEC Standard Packing Transportation Special Claim / Requirement 11 Frequently Used Catalogue Numbers Product Code Outlet Current IP Length (A) Protection (m) Product Description Straight length WPLTGBE0T0IP54-20 0 25 IP54 2 2m, IP54, Bus trunking system(along current direction, no circuit on left side,no socket; along current direction, 25A circuit on right side, no socket) WPLTGBE0T0IP54-30 0 25 IP54 3 3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, no socket) WPLTGBE0T1IP54-20 1 25 IP54 2 2m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, with 1 socket) WPLTGBE0T1IP54-30 1 25 IP54 3 3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, with 1 socket) WPLTGBE0T2IP54-20 2 25 IP54 2 2m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, with 2 sockets) WPLTGBE0T2IP54-30 2 25 IP54 3 3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, with 2 sockets) WPLTGBE0T3IP54-30 3 25 IP54 3 3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, with 3 sockets) WPLTGBE0F0IP54-20 0 40 IP54 2 2m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, no socket) WPLTGBE0F0IP54-30 0 40 IP54 3 3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, no socket) WPLTGBE0F1IP54-20 1 40 IP54 2 2m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, with 1 socket) WPLTGBE0F1IP54-30 1 40 IP54 3 3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, with 1 socket) WPLTGBE0F2IP54-20 2 40 IP54 2 2m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, with 2 sockets) WPLTGBE0F2IP54-30 2 40 IP54 3 3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, with 2 sockets) WPLTGBE0F3IP54-30 3 40 IP54 3 3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, with 3 sockets) WPLTGBT0E0IP54-20 0 25 IP54 2 2m, IP54, Bus trunking system(along current direction, 25A circuit on left side, no socket; along current direction, no circuit on right side, no socket) WPLTGBT0E0IP54-30 0 25 IP54 3 3m, IP54, Bus trunking system(along current direction, 25A circuit on left side, no socket; along current direction, no circuit on right side, no socket) WPLTGBT1E0IP54-20 1 25 IP54 2 2m, IP54, Bus trunking system(along current direction, 25A circuit on left side, with 1 socket; along current direction, no circuit on right side, no socket) WPLTGBT1E0IP54-30 1 25 IP54 3 3m, IP54, Bus trunking system(along current direction, 25A circuit on left side, with 1 socket; along current direction, no circuit on right side, no socket) WPLTGBT2E0IP54-20 2 25 IP54 2 2m, IP54, Bus trunking system(along current direction, 25A circuit on left side, with 2 sockets; along current direction, no circuit on right side, no socket) WPLTGBT2E0IP54-30 2 25 IP54 3 3m, IP54, Bus trunking system(along current direction, 25A circuit on left side, with 2 sockets; along current direction, no circuit on right side, no socket) WPLTGBT3E0IP54-30 3 25 IP54 3 3m, IP54, Bus trunking system(along current direction, 25A circuit on left side, with 3 sockets; along current direction, no circuit on right side,no socket) WPLTGBF0E0IP54-20 0 40 IP54 2 2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, no circuit on right side, no socket) WPLTGBF0E0IP54-30 0 40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side,no socket; along current direction, no circuit on right side, no socket) WPLTGBF1E0IP54-20 1 40 IP54 2 2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, no circuit on right side, no socket) WPLTGBF1E0IP54-30 1 40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, no circuit on right side, no socket) WPLTGBF2E0IP54-20 2 40 IP54 2 2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, no circuit on right side, no socket) WPLTGBF2E0IP54-30 2 40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, no circuit on right side, no socket) WPLTGBF3E0IP54-30 3 40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 3 sockets; along current direction, no circuit on right side, no socket) WPLTGBF0F0IP54-20 0 40+40 IP54 2 2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, no socket) WPLTGBF0F0IP54-30 0 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, no socket) WPLTGBF0F1IP54-20 1 40+40 IP54 2 2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, with 1 socket) WPLTGBF0F1IP54-30 1 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, with 1 socket) WPLTGBF0F2IP54-20 2 40+40 IP54 2 2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, with 2 sockets) WPLTGBF0F2IP54-30 2 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, with 2 sockets) WPLTGBF0F3IP54-30 3 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, with 3 sockets) WPLTGBF1F0IP54-20 1 40+40 IP54 2 2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, 40A circuit on right side, no socket) WPLTGBF1F0IP54-30 1 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, 40A circuit on right side, no socket) WPLTGBF1F1IP54-20 2 40+40 IP54 2 2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, 40A circuit on right side, with 1 socket) WPLTGBF1F1IP54-30 2 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, 40A circuit on right side, with 1 socket) WPLTGBF1F2IP54-20 3 40+40 IP54 2 2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, 40A circuit on right side, with 2 sockets) WPLTGBF1F2IP54-30 3 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, 40A circuit on right side, with 2 sockets) WPLTGBF1F3IP54-30 4 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, 40A circuit on right side, with 3 sockets) WPLTGBF2F0IP54-20 2 40+40 IP54 2 2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, 40A circuit on right side, no socket) WPLTGBF2F0IP54-30 2 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, 40A circuit on right side, no socket) WPLTGBF2F1IP54-20 3 40+40 IP54 2 2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, 40A circuit on right side, with 1 socket) WPLTGBF2F1IP54-30 3 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, 40A circuit on right side, with 1 socket) WPLTGBF2F2IP54-20 4 40+40 IP54 2 2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, 40A circuit on right side, with 2 sockets) WPLTGBF2F2IP54-30 4 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, 40A circuit on right side, with 2 sockets) WPLTGBF2F3IP54-30 5 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side,with 2 sockets; along current direction, 40A circuit on right side, with 3 sockets) WPLTGBF3F0IP54-30 3 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 3 sockets; along current direction, 40A circuit on right side, no socket) WPLTGBF3F1IP54-30 4 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 3 sockets; along current direction, 40A circuit on right side, with 1 socket) WPLTGBF3F2IP54-30 5 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 3 sockets; along current direction, 40A circuit on right side, with 2 sockets) WPLTGBF3F3IP54-30 6 40+40 IP54 3 3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 3 sockets; along current direction, 40A circuit on right side, with 3 sockets) 12 Product Code Outlet Current IP Length (A) Protection (m) Product Description Elbow 2m, IP54, Elbow(with one input and one output terminal box)(along current direction, no circuit on left side, no socket; along current direction,25A circuit on right side,no socket) 3m, IP54, Elbow(with one input and one output terminal box)(along current direction, no circuit on left side, no socket; along current direction,25A circuit on right side,no socket) 2m, IP54, Elbow(with one input and one output terminal box)(along current direction, 25A circuit on left side, no socket; along current direction, no circuit on right side,no socket) 3m, IP54, Elbow(with one input and one output terminal box)(along current direction, 25A circuit on left side, no socket; along current direction, no circuit on right side,no socket) 2m, IP54, Elbow(with one input and one output terminal box)(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side,no socket) 3m, IP54, Elbow(with one input and one output terminal box)(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side,no socket) 2m, IP54, Elbow(with one input and one output terminal box)(along current direction, 40A circuit on left side, no socket; along current direction, no circuit on right side,no socket) 3m, IP54, Elbow(with one input and one output terminal box)(along current direction, 40A circuit on left side, no socket; along current direction, no circuit on right side,no socket) 2m, IP54, Elbow(with one input and one output terminal box)(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side,no socket) 3m, IP54, Elbow(with one input and one output terminal box)(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side,no socket) WPLTGEE0T0IP54-20 0 25 IP54 2 WPLTGEE0T0IP54-30 0 25 IP54 3 WPLTGET0E0IP54-20 0 25 IP54 2 WPLTGET0E0IP54-30 0 25 IP54 3 WPLTGEE0F0IP54-20 0 40 IP54 2 WPLTGEE0F0IP54-30 0 40 IP54 3 WPLTGEF0E0IP54-20 0 40 IP54 2 WPLTGEF0E0IP54-30 0 40 IP54 3 WPLTGEF0F0IP54-20 0 40+40 IP54 2 WPLTGEF0F0IP54-30 0 40+40 IP54 3 WPLTGFE0T0IP54-20 0 25 IP54 2 2m, IP54,Feeder box(with flexible tube)(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, no socket) WPLTGFE0T0IP54-30 0 25 IP54 3 3m, IP54, Feeder box(with flexible tube)(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, no socket) WPLTGFT0E0IP54-20 0 25 IP54 2 2m, IP54, Feeder box(with flexible tube)(along current direction, 25A circuit on left side, no socket; along current direction, no circuit on right side, no socket) WPLTGFT0E0IP54-30 0 25 IP54 3 3m, IP54, Feeder box(with flexible tube)(along current direction, 25A circuit on left side, no socket; along current direction, no circuit on right side, no socket) WPLTGFE0F0IP54-20 0 40 IP54 2 2m, IP54, Feeder box(with flexible tube)(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, no socket) WPLTGFE0F0IP54-30 0 40 IP54 3 3m, IP54, Feeder box(with flexible tube)(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, no socket) WPLTGFF0E0IP54-20 0 40 IP54 2 2m, IP54, Feeder box(with flexible tube)(along current direction, 40A circuit on left side, no socket; along current direction, no circuit on right side, no socket) WPLTGFF0E0IP54-30 0 40 IP54 3 3m, IP54, Feeder box(with flexible tube)(along current direction, 40A circuit on left side, no socket; along current direction, no circuit on right side, no socket) WPLTGFF0F0IP54-20 0 40+40 IP54 2 2m, IP54, Feeder box(with flexible tube)(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, no socket) WPLTGFF0F0IP54-30 0 40+40 IP54 3 3m, IP54, Feeder box(with flexible tube)(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, no socket) Feeder Product Code Outlet IP (A) Protection Length (m) Phase Product Description Plug WPLTGP10L1IP54-10 10 IP54 1 L1 phase L1 (phase A) output10APlug WPLTGP10L1IP54-20 10 IP54 2 L1 phase L1 (phase A) output10APlug WPLTGP10L2IP54-10 10 IP54 1 L2 phase L2 (phase B) output10APlug WPLTGP10L2IP54-20 10 IP54 2 L2 phase L2 (phase B) output10APlug WPLTGP10L3IP54-10 10 IP54 1 L3 phase L3 (phase C) output10APlug WPLTGP10L3IP54-20 10 IP54 2 L3 phase L3 (phase C) output10APlug WPLTGP16L1IP54-10 16 IP54 1 L1 phase L1 (phase A) output16APlug WPLTGP16L1IP54-20 16 IP54 2 L1 phase L1 (phase A) output16APlug WPLTGP16L2IP54-10 16 IP54 1 L2 phase L2 (phase B) output16APlug WPLTGP16L2IP54-20 16 IP54 2 L2 phase L2 (phase B) output16APlug WPLTGP16L3IP54-10 16 IP54 1 L3 phase L3 (phase C) output16APlug WPLTGP16L3IP54-20 16 IP54 2 L3 phase L3 (phase C) output16APlug Product Code Product Description Accessory WPLTGAHGB Fixing Bracket WPLTGACLP Snap Clamp WPLTGACBC Cable Clamp WPLTGAFXS Fixing Clamp WPLTGAFXB Suspension Bracket WPLTGAMHK Mouse Hook 13 Catalogue Numbering System WavePro LTG lighting busway can be ordered by catalogue number, please contact GE engineer to place order in accordance with below catalog numbering system. Trunking System WavePro Busway System Lighting Busway WP LTG Current Rating & Number of Outlet (left) Type B: Busway E0: along current flow, no left way C: Terminal Unit T0: along current flow, left 25A, no outlet E: Flexible Elbow (with two terminal units) T1: along current flow, left 25A, one outlet F: Feed Unit (with flexible pipe) Current Rating & Number of Outlet (right) E0: along current flow, no right way IP40 T0: along current flow, right 25A, no outlet IP42 T1: along current flow, right 25A, one outlet IP43 T2: along current flow, right 25A, two outlets IP54 F0: along current flow, right 40A, no outlet T3: along current flow, left 25A, three outlets F1: along current flow, right 40A, one outlet F2: along current flow, right 40A, two outlets F1: along current flow, left 40A, one outlet F2: along current flow, left 40A, two outlets Length T3: along current flow, right 25A, three outlets T2: along current flow, left 25A, two outlets F0: along current flow, left 40A, no outlet Degree of Protection F3: along current flow, right 40A, three outlets -05: 0.5m -10: 1m -20: 2m -30: 3m -xx: other non-standard length or no length unit F3: along current flow, left 40A, three outlets Tap-off Unit WavePro Busway System Lighting Busway Type WP LTG P: Tap-off Unit (Plug) Current Rating Phase Degree of Protection 10: 10A L1: L1or A Phase IP40 -10: 1m 16: 16A L2: L2 or B Phase IP42 -20: 2m L3: L3 or C Phase IP43 -xx: other non-standard length IP54 Accessories WavePro Busway System Lighting Busway Type WP LTG A: Accessory Component HGB (Fixing Bracket) CLP (Snap Clamp) CBC (Cable Clamp) FXS (Fixing Clamp) FXB (Suspension Bracket) MHK (Mouse Hook) GE Lighting & Industrial assumes no obligation of notice to holders of this document with respect to changes and reserves the right to explain finally for this publication. 14 Cable Length 15 REGIONAL OFFICES BRANCH OFFICES NORTH Gurgaon Chandigarh Lucknow GE India Industrial Pvt. Ltd. 5th Floor, Building No.7A DLF Cyber City, DLF Phase-III Sector 25 A, Gurgaon Haryana – 122002 Ph: (0124) 4808000 Fax: (0124) 4226911 / 4226912 GE India Industrial Pvt. Ltd. SCO No. 72 & 73, First Floor Sector 8/C, Madhya Marg Chandigarh-160008 Ph: (0172) 3982908-10 Fax: (0172) 3982905 GE India Industrial Pvt. Ltd. 101, Ace Business Center 19, Vidhan Sabha Marg Lucknow-226001 Ph: (0522) 3203808, 3012444/666 Fax: (0522) 4045909 Bangalore Chennai Coimbatore Cochin Hyderabad GE India Industrial Pvt. Ltd. The Millenia, Level-6, Tower B 1 & 2, Murphy Road, Ulsoor Bangalore-560008 Ph: (080) 41434000 Fax: (080) 41434199 GE India Industrial Pvt. Ltd. Temple Tower, 6th Floor 476, (New No. 672) Anna Salai Nandanam Chennai-600035 Ph: (044) 45070470-84 Fax: (044) 45070474 GE India Industrial Pvt. Ltd. No.36/6 & 7, 1st Floor Ashirwad Building D.B.Road, R.S. Puram Coimbatore-641002 Ph: (0422) 4393520 / 4393529 GE India Industrial Pvt. Ltd. Mayur Business Center & Motel Chittur Road, Pullepadi Junction Cochin-682035 Ph: (0484) 2364139 Fax: (0484) 4031400 GE India Industrial Pvt. Ltd. 5-2-45, Hyderbasti, RP Road Near Gujarati High School Secunderabad-500003 Ph: (040) 27543162, 66311264 Fax: (040) 66339272 Mumbai Ahmedabad Pune GE India Industrial Pvt. Ltd. 361/362, Solitaire Corporate Park M. Vasanji Road, Chakala Andheri (E), Mumbai-400093 Ph: (022) 40101610 Fax: (022) 40101611 GE India Industrial Pvt. Ltd. 405-406, Kirtiman Complex Kinariwala House, Behind Citibank Off C.G. Road, Ahmedabad-380006 Ph: (079) 65427385/65427389 Fax: (079) 26460637 GE Money Financial Services Limited Shop No. 405-410, 4th Floor City Point, Dhole Patil Road Pune-411001 Ph: (020) 41266999 Fax: (020) 41266109 SOUTH WEST 1204/BUSWAYS/CAT/LTG EAST Kolkata GE India Industrial Pvt. Ltd. Horizon Building, 4th Floor 57, Chowringhee Road Kolkata-700071 Ph: (033) 40034056 Fax: (033) 40034071 We are committed to continuous development and improvement of our products and the specifications are subject to change without notice. For product availability and latest prices, please contact GE Sales Team. For any further information, visit us at http://www.geindustrial.com g and General Electric are registered trade marks of General Electric Co. USA © Works: GE India Industrial Pvt. Ltd. Plot No. 42/1 & 45/14 Electronic City - Phase II Bangalore-560100 Ph: (080) 41113000 Fax: (080) 28528469/552 HO: GE India Industrial Pvt. Ltd. The Millenia, Level-6, Tower B 1 & 2, Murphy Road, Ulsoor Bangalore-560008 Ph: (080) 41434000 Fax: (080) 41434199 Email: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com