REGIONAL OFFICES BRANCH OFFICES

advertisement
WavePro LTG
Lighting Busway
GE
GE is a diversified organization covering a myriad of market segments, including infrastructure, finance and media.
From energy, water, transportation and health to access to money and information, GE serves customers in more than
100 countries and employs more than 300,000 people worldwide.
The company traces its beginnings from Thomas A. Edison, who established the Edison Electric Light Company in 1878.
In 1892, a merger of Edison General Electric Company and Thomson-Houston Electric Company created the General
Electric Company. GE is the only company listed in the Dow Jones Industrial Index today that was also included in the
original index in 1896.
Industrial Solutions
GE Industrial Solutions, a division of GE Energy, is a global leading provider in power distribution, offering a wide range
of products which includes medium and low voltage power distribution equipments and components, and motor &
control systems that are safe, reliable and offer high performance. Its innovative solutions can improve energy
efficiency and environmental impact in power plants, power grids, oil & gas, mining, data center, overseas EPC,
industrial manufacturing, rail transportation, commercial buildings, residential houses, renewable energy and many
other industries.
GE is one of the worldwide partners of the Olympic Games. In 2008, GE assisted
Beijing with this tremendous event, which was unprecedented in scale and
first-class in its use of science and technology, offering a series of innovative
solutions and products for around 400 Olympic infrastructure projects, covering
fields in electricity distribution, lighting, security, water processing, benefiting
some 37 Olympic venues and 168 commercial buildings. GE also brought its
experiences to the 2010 Expo in Shanghai, Asia Games in Guangzhou,
Vancouver Olympic Games and will continue through to the London 2012
Olympic Games.
2010 World's Most Innovative Companies
2011 World’s Most Admired Companies
2009 World’s Most Respected Companies
2011 Best Global Brand
2008 World’s Most Respected Companies
2007 World’s Best R&D Companies
Quick Index
1
2
3
4
System Overview
Features & Advantages
Certification & Standard
Electrical Characteristics
Basic Electrical Characteristics
Electrical Characteristics for Conductor
Effect of Ambient Temperature during Application
Weight of Busway
5
Components Features
Straight Length
6
Feed Unit
End Cover
Flexible Elbow
Specifications & Data
Straight Length
Feed Unit
Tap-off Unit
Flexible Elbow
8Accessories
9
Fixing Bracket
Snap Clamp
Cable Clamp
Fixing Clamp
Suspension Bracket
Mouse Hook
Application & Installation
Straight Length & Feed Unit
Lighting Busway
Other Installation Examples
Start Notice
Installation Requirements
11
12
14
4
Ordering Information
Frequently Used Catalogue Numbers
Catalogue Numbering System
System Overview
WavePro LTG is a modularized busway to distribute electric power for
lighting system by simple plugging connection, which is able to provide
sufficient power branches as necessary and protection while extending
mechanical support for the weight of lighting fixture underneath.
WavePro LTG is constructed with a high-quality extruded aluminium
alloy housing having characteristics such as, light in weight, compact in
size, offering high mechanical strength.
WavePro LTG utilizes high-quality copper as conductors and Al housing
as ground; copper conductors are enclosed with a environmental
friendly low-smoke, halogen-free and flame retardant insulation.
WavePro LTG can be customized with multiple-number of outlets
according to actual application offering flexibility for installation and
power distribution to be adopted in complex situations.
WavePro LTG can be installed vertically as well as horizontally onto the
truss, ceiling, wall and floor, this makes it a preferred choice to energize
middle to large commercial lighting and places with low load situations
such as: airports, subway stations, workshops, exhibition halls,
warehouses, shopping malls.
WavePro LTG mainly consists of straight lengths, feed units, terminal
units, flexible elbows, tap-off units and accessories such as cable
clamps, various fixing brackets. All units and accessories are
standardized, modularized during designing and producing in order to
ensure easier installation and application.
1
WavePro LTG
Features & Advantages
Compact and flexible
•
•
WavePro LTG lighting busway , will save space while compared to cables due to its compact housing
size of 48mm×32mm
Various functional units, components can be used at any corner, to bypass obstacles, as well as change height of busway routing by using flexible elbows, which offers flexibility for adopting routing to any construction space
Safe and reliable plug unit
•
•
•
2
WavePro LTG plug unit uses flame-retardant ABS plastic body and has features such as compact and light weight design, offering high strength in addition to extended life and excellent insulation
Silver-plated spring stabs provide reliable electrical connection; longer grounding pin design makes
contact first but leaves last when compared to phase pins offering grounding protection
Clamps adjacent to plug unit can lock onto busway trunk and ensure reliable electrical contact
with enhanced degree of protection
Aluminium alloy housing
•
•
•
WavePro LTG uses complete aluminium alloy housing throughout the length, offering features such as lighter weight, higher strength, and protection degree upto IP54
WavePro LTG housing has excellent anti-corrosion properties and has grounding capacity at least
50% equivalent to phase conductors
WavePro LTG comprises materials which minimize magnetic hysteresis loss, enhancing efficiency of
energy transfer and reducing the voltage drop of the system
Safe insulating material
•
•
WavePro LTG Lighting busways use environment friendly and low smoke halogen-free flame retardant materials
Supporting insulation parts have been successfully type tesed by glow wire test at 9600C;
Non-supporting insulation parts have been successfully type tested by glow wire test at 6500C
Easy installation
•
•
Interconnection between trunk units, feed units, terminal units, flexible elbows, joints can be carried out by "insertion" action for achieving proper installation whilst ensuring satisfactory electrical and
mechanical performance
There is a feature to prevent wrong insertion, design and construction of adjacent units is done in such a way that they can only be connected with each other in proper way as per phase orientation, configuration declared in ordering information
Certification & Standard
• EN60439-2: 2000 + A1: 2005
• IEC60439-2: 2000 + A1: 2005
3
Electrical Characteristics
Basic Electrical Characteristics
Rated
Current
(A)
Rated Voltage
(V AC)
Rated Insulation
Voltage (V AC)
Frequency
(Hz)
Short Cicuit Withstand
Current (t=1s)
(kA)
25
40
2×25
2×40
415
415
415
415
690
690
690
690
50/60
50/60
50/60
50/60
0.69
0.94
0.69
0.94
Degree of
Protection
Number
of Wire
Material of
Conductor
Cross Section of
Conductor
(L1, L2, L3, N)
(mm2)
IP40 / IP42 /
IP43 / IP54
4
4
4
4
Cu
Cu
Cu
Cu
4
6
2×4
2×6
Tab. 4-1
Electrical Characteristics for Conductor
Degree of
Current
A
25
40
Single Phase Conductor
Protective Conductor
Voltage Drop
Voltage drop of single phase
Mean resistance at an ambient Mean resistance at an ambient
temperature of 200C
(The three-phases network voltage drop is obtained by multiplying 0.866)
temperature of 200C (R20)
V/100m/A
10-6Ω/m
10-6Ω/m
Power factor Power factor Power factor Power factor Power factor
CosΦ=0.6
CosΦ=0.7
CosΦ=0.8
CosΦ=0.9
CosΦ=1.0
4609.3
301.3
0.50
0.58
0.66
0.73
0.80
3072.8
301.3
0.34
0.39
0.44
0.49
0.53
Tab. 4-2
Effect of Ambient Temperature during Application
Ambient Temperature (0C)
35
40
45
50
55
60
Factor
1
0.95
0.90
0.85
0.80
0.75
Tab. 4-3
Within the ambient temperature of 350C, WavePro LTG Lighting busway can continuously operate at rated current while the maximum
housing temperature rise will not exceed 55K.
If the busway is continuously operated at higher ambient temperature, it should be derated first, i.e. the busway current-carrying
capacity=rated current × de-rating factor. (As shown in Tab. 4-3).
Weight of Busway
Type
25A
40 A
25 A +40 A
25 A ×2
40 A ×2
Tab. 4-4
4
Weight (kg/m)
0.9
1.0
1.2
1.1
1.3
Components Features
Straight Length
Straight Length plays important role in lighting busway and they are functional with just
a simple direct "head" to "tail" insertion.
Fig. 5-1
• Aluminium alloy housing (size of 48×32mm), acts as PE, with features such as good
mechanical strength, lesser weight and it also improves aesthetical appearance
• Standard straight trunk is as long as 2m or 3m, while outlets' spacing is 0.5m or 1
meter. Non-standard lengths can be customized in consultation with our engineers
• Degree of Protection available up to IP54
• Fire retardant insulations are in line with the performance of GB and IEC standards
(IEC 60695-2-1)
-Supportive insulating parts are able to withstand the pressure of glow wire at 9600C
-Non-supportive insulating parts are able to withstand the pressure of glow wire at
6500C
Span of Installation (m)
2.0
2.5
3.0
Concentrated Load (kg)
18
14
12
Average Load (kg)
27
24
18
Tab. 5-1
Feed Unit
Power supply to the lighting busway originates from Feed Unit; the installation between
a feed unit and a straight length is similar to two straight lengths connecting each other,
inserting head into housing and pressing buttons in position to lock.
Fig. 5-2
End Cover
End cover (or terminal unit) completes the end of the lighting busway. The installation is
similar to straight length.
Fig. 5-3
Flexible Elbow
Fig. 5-4
Flexible elbow consists of two feed units which are connected through a flexible tube.
You can change the direction or height of the busway, or bypassing an obstacle by
using the flexible length, the installation method is same as joining two straight length.
There are 0.5m, 1m in two standard lengths, while the non-standard lengths can be
customized.
5
Specifications & Data
Straight Length
Left
Right
Current entry
Joint groove downward
2m Single-circuit, dual-circuit dimension & layout of sockets
800
700
N
L3
L2
L1
2 2m Dual-circuit
500
800
48
32
700
N
L3
L2
L1
48
500
Unit: mm
N
L3
L2
L1
1 2m Single-circuit
32
2000
800
800
700
N
L3
L2
L1
3 3m Single-circuit
500
800
800
900
32
N
L3
L2
L1
4 3m Dual-circuit
500
800
800
48
500
500
900
N
L3
L2
L1
48
700
32
3000
900
Straight length
• For the single-circuit busway, the unit with
standard length of 2m has maximum 2
sockets, while the 3m has maximum
3 sockets
• For the dual-circuit busway, the unit with
standard length of 2m has maximum 4 (2
for each side) sockets, while the 3m has
maximum 6 sockets (3 for each side)
• More sockets are available for customized
applications
6
800
800
Num
Cat. #
1
2
3
4
WPLTGBT2E0IP54-20
WPLTGBF2F1IP54-20
WPLTGBT3E0IP54-30
WPLTGBT3T3IP54-30
500
Number of
Outlet
Left 2
Left2Right1
Left3
Left3Right3
Rated Current
(A)
25
40×2
25
25×2
Tab. 6-1
Please refer to Catalogue Numbering System for more.
Degree of Measures
Protection
(m)
2
2
IP54
3
3
Feed Unit
• Feed unit has insulation shield (dual-circuit line busway has separate two circuits)
• Three sides of the feed unit will have sockets and knock off holes at the right, left and end side
• Special sealed connector is used to connect the flexible length
• Used to connect 2.5mm² -10mm² cable
Cat. #
Type
WPLTGFF0E0IP54-20
WPLTGFF0F0IP54-20
WPLTGFT0E0IP54-30
WPLTGFT0T0IP54-30
Feed Unit
Feed Unit
Feed Unit
Feed Unit
Rated Current
(A)
40
40×2
25
25×2
Degree of
Protection
IP54
Pipe length
(m)
2
2
3
3
Tab. 7-1
Please refer to Catalogue Numbering System for more.
Unit: mm
145
135
ø32
120
130
Tap-off Unit (Plug)
•
•
•
Tap-off unit has 3 wires. It can be converted into L1, N, PE or L2, N, PE or L3, N, PE
Meets IEC60332-1 Flammability Property
Purchaser can specify cable length and type
Cat.#
Type
WPLTGP10L1IP54-10
WPLTGP16L2IP54-20
Plug
Plug
Degree of
Current (A)
10
16
Phase
Degree of
Protection
L1
L2
IP54
Cable length
(m)
1
2
Tab. 7-2
Please refer to Catalogue Numbering System for more.
Unit: mm
48
57
24
Flexible Elbow
Unit: mm
140
B
B is 0.5m typically.
Cat.#
WPLTGEE0T0IP54-05
WPLTGET0E0IP54-10
WPLTGEE0F0IP54-05
WPLTGEF0E0IP54-10
Number of
Outlets
0
0
0
0
Rated Current
(A)
25
25
40
40
Degree of
Protection
IP54
Pipe length
(m)
0.5
1
0.5
1
Tab. 7-3
Please refer to catalogue numbering system for further details.
7
Accessories
2
3
6
1
Code
5
Description
1
Fixing Bracket
2
Snap Clamp
3
Cable Clamp
4
Fixing Clamp
5
Suspension Bracket
6
Mouse Hook
4
1 Fixing Bracket
4 Fixing Clamp
Fixing bracket is used to suspend the lighting busway and fixtures
with cable or chain, it can also be used to support the joint area
to improve mechanical strength.
Fixing clamp is used to fix and support the busway when
the lighting busway is installed under the floor.
69
Unit: mm
85
46
Unit: mm
20
15
85
37
200
Cat.#: WPLTGAHGB
Cat.#: WPLTGAFXS
2 Snap Clamp
5 Suspension Bracket
Snap clamp is used to suspend the straight length or for the
installation of the lighting fixtures (balanced load). It can be used
to fix the selected straight length.
Suspension bracket is used to suspend and fix the busway
when the lighting busway is installed under the ceiling.
20
Unit: mm
112
79
Unit: mm
25
30
39
Cat.#: WPLTGACLP
Cat.#: WPLTGAFXB
3 Cable Clamp
6 Mouse Hook
Cable can be fixed on a straight length by using cable clamp to
simplify the line strike and save space.
Mouse hook is used in conjunction with the fix bracket to fix
the lighting busway on the buildings.
40
Unit: mm
Unit: mm
157
28
10
39
Cat.#: WPLTGACBC
Cat.#: WPLTGAMHK
M6
8
Application & Installation
Straight Length & Feed Unit
The installation of two straight lengths is illustrated as below.
Each length of the system plugs into the adjacent length with just
a push, for electrical and mechanical connection. Kindly ensure
the joint is pushed fully together leaving no gap.
Fig. 9-1
Fig. 9-2
The installation of feed unit and straight length is the same as the
installation of two straight lengths. The Feed unit plugs into the
adjacent length with a push, ensuring electrical and mechanical
connection. Kindly ensure the joint is pushed fully together
leaving no gap.
Lighting Busway Typical Installation
The lighting busway will be fixed on the construction. Appropriate
support accessories are to be selected for the installation. Fig. 9-3
shows the lighting busway's installation on the beam.
Fig. 9-3
Other Installation Examples
1. Suspension Installation
Fig. 9-4
2. Side Installation
Fig. 9-5
Please refer to the installation instructions for details.
9
Start Notice
Determine how the Busway is to be installed so as to ensure correct
phase sequence throughout the system.
The Busway housing consists of two parts: "Π" part and "" part (Fig.
10-1). Correct installation should be in such a way that it meets
claimed IP42/43/IP54 protective grade: the hatch of the "Π" part
should be oriented to downward (Fig 10-1), the outlet (if have) at side
of housing.
Fig. 10-1
Installation Requirements
Please select appropriate accessories in accordance with the actual
situation and installation drawings and ensure the installation of the
lighting busway, the mounting brackets and other accessories is
in line with the bus strike. For Installation space please refer the
following • The installation distance between any straight lengths is not more than 3 m, the specific spacing requirements of installation
should be illustrated in the installation drawings in accordance
with the conditions and circumstances at the site.
(For spacing and load-bearing capacity of installation, please see the table 10.1)
• The mounting brackets should be set up at both ends of the joint, while the maximum spacing should not exceed 1 m
10
Span of
Installation (m)
Concentrated
Load (kg)
Average Load (kg)
2.0
2.5
3.0
18
14
12
27
24
18
Tab. 10-1
Ordering Information
Lighting Busway Technical Agreement List
Project Name: ________________________________ Project No: _________________________ Product Type: ________________________________ WavePro LTG: _______________________ Quantity: ____________________________________
Connecting Drawing: _________________
Busway Arrangement Drawing: _____________________
BOM: ______________________________
Item
WavePro LTG Busway Technical Data
Standard
 GB 7251.1&2-2006
 IEC-60439-1&2
Service Condition
Relative humidity not exceed 90% at +200C
Altitude (m)
 <2000
0
Max. Ambient temperature C
0
 40
Min. Ambient temperature C
 -5
Average Ambient temperature0C
 35
Power Source
Rated Voltage (V)
415
Rated Frequency (Hz)
50 Phase
3
60
Busway Utility Data
Rated Current (A)
25
40
20×2 Number of Phase
3P5W L1,L2,L3,N100%,PE50% (housing grounding)
Protection Degree
IP40
IP42
Short-time Withstand Current (kA/1s)
0.69 (25A circuit)
0.94 (40A circuit)
Phase Sequence
L1,L2,L3, N,PE(From Top to Bottom)
Other
Phase Color:
GB Standard
IP43
40×2
25+40
IP54
IEC Standard
Packing
Transportation
Special Claim / Requirement
11
Frequently Used Catalogue Numbers Product Code
Outlet
Current
IP
Length
(A)
Protection (m)
Product Description
Straight length
WPLTGBE0T0IP54-20
0
25
IP54
2
2m, IP54, Bus trunking system(along current direction, no circuit on left side,no socket; along current direction, 25A circuit on right side, no socket)
WPLTGBE0T0IP54-30
0
25
IP54
3
3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, no socket)
WPLTGBE0T1IP54-20
1
25
IP54
2
2m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, with 1 socket)
WPLTGBE0T1IP54-30
1
25
IP54
3
3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, with 1 socket)
WPLTGBE0T2IP54-20
2
25
IP54
2
2m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, with 2 sockets)
WPLTGBE0T2IP54-30
2
25
IP54
3
3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, with 2 sockets)
WPLTGBE0T3IP54-30
3
25
IP54
3
3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, with 3 sockets)
WPLTGBE0F0IP54-20
0
40
IP54
2
2m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, no socket)
WPLTGBE0F0IP54-30
0
40
IP54
3
3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, no socket)
WPLTGBE0F1IP54-20
1
40
IP54
2
2m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, with 1 socket)
WPLTGBE0F1IP54-30
1
40
IP54
3
3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, with 1 socket)
WPLTGBE0F2IP54-20
2
40
IP54
2
2m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, with 2 sockets)
WPLTGBE0F2IP54-30
2
40
IP54
3
3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, with 2 sockets)
WPLTGBE0F3IP54-30
3
40
IP54
3
3m, IP54, Bus trunking system(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, with 3 sockets)
WPLTGBT0E0IP54-20
0
25
IP54
2
2m, IP54, Bus trunking system(along current direction, 25A circuit on left side, no socket; along current direction, no circuit on right side, no socket)
WPLTGBT0E0IP54-30
0
25
IP54
3
3m, IP54, Bus trunking system(along current direction, 25A circuit on left side, no socket; along current direction, no circuit on right side, no socket)
WPLTGBT1E0IP54-20
1
25
IP54
2
2m, IP54, Bus trunking system(along current direction, 25A circuit on left side, with 1 socket; along current direction, no circuit on right side, no socket)
WPLTGBT1E0IP54-30
1
25
IP54
3
3m, IP54, Bus trunking system(along current direction, 25A circuit on left side, with 1 socket; along current direction, no circuit on right side, no socket)
WPLTGBT2E0IP54-20
2
25
IP54
2
2m, IP54, Bus trunking system(along current direction, 25A circuit on left side, with 2 sockets; along current direction, no circuit on right side, no socket)
WPLTGBT2E0IP54-30
2
25
IP54
3
3m, IP54, Bus trunking system(along current direction, 25A circuit on left side, with 2 sockets; along current direction, no circuit on right side, no socket)
WPLTGBT3E0IP54-30
3
25
IP54
3
3m, IP54, Bus trunking system(along current direction, 25A circuit on left side, with 3 sockets; along current direction, no circuit on right side,no socket)
WPLTGBF0E0IP54-20
0
40
IP54
2
2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, no circuit on right side, no socket)
WPLTGBF0E0IP54-30
0
40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side,no socket; along current direction, no circuit on right side, no socket)
WPLTGBF1E0IP54-20
1
40
IP54
2
2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, no circuit on right side, no socket)
WPLTGBF1E0IP54-30
1
40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, no circuit on right side, no socket)
WPLTGBF2E0IP54-20
2
40
IP54
2
2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, no circuit on right side, no socket)
WPLTGBF2E0IP54-30
2
40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, no circuit on right side, no socket)
WPLTGBF3E0IP54-30
3
40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 3 sockets; along current direction, no circuit on right side, no socket)
WPLTGBF0F0IP54-20
0
40+40
IP54
2
2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, no socket)
WPLTGBF0F0IP54-30
0
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, no socket)
WPLTGBF0F1IP54-20
1
40+40
IP54
2
2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, with 1 socket)
WPLTGBF0F1IP54-30
1
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, with 1 socket)
WPLTGBF0F2IP54-20
2
40+40
IP54
2
2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, with 2 sockets)
WPLTGBF0F2IP54-30
2
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, with 2 sockets)
WPLTGBF0F3IP54-30
3
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, with 3 sockets)
WPLTGBF1F0IP54-20
1
40+40
IP54
2
2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, 40A circuit on right side, no socket)
WPLTGBF1F0IP54-30
1
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, 40A circuit on right side, no socket)
WPLTGBF1F1IP54-20
2
40+40
IP54
2
2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, 40A circuit on right side, with 1 socket)
WPLTGBF1F1IP54-30
2
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, 40A circuit on right side, with 1 socket)
WPLTGBF1F2IP54-20
3
40+40
IP54
2
2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, 40A circuit on right side, with 2 sockets)
WPLTGBF1F2IP54-30
3
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, 40A circuit on right side, with 2 sockets)
WPLTGBF1F3IP54-30
4
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 1 socket; along current direction, 40A circuit on right side, with 3 sockets)
WPLTGBF2F0IP54-20
2
40+40
IP54
2
2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, 40A circuit on right side, no socket)
WPLTGBF2F0IP54-30
2
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, 40A circuit on right side, no socket)
WPLTGBF2F1IP54-20
3
40+40
IP54
2
2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, 40A circuit on right side, with 1 socket)
WPLTGBF2F1IP54-30
3
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, 40A circuit on right side, with 1 socket)
WPLTGBF2F2IP54-20
4
40+40
IP54
2
2m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, 40A circuit on right side, with 2 sockets)
WPLTGBF2F2IP54-30
4
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 2 sockets; along current direction, 40A circuit on right side, with 2 sockets)
WPLTGBF2F3IP54-30
5
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side,with 2 sockets; along current direction, 40A circuit on right side, with 3 sockets)
WPLTGBF3F0IP54-30
3
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 3 sockets; along current direction, 40A circuit on right side, no socket)
WPLTGBF3F1IP54-30
4
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 3 sockets; along current direction, 40A circuit on right side, with 1 socket)
WPLTGBF3F2IP54-30
5
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 3 sockets; along current direction, 40A circuit on right side, with 2 sockets)
WPLTGBF3F3IP54-30
6
40+40
IP54
3
3m, IP54, Bus trunking system(along current direction, 40A circuit on left side, with 3 sockets; along current direction, 40A circuit on right side, with 3 sockets)
12
Product Code
Outlet
Current
IP
Length
(A)
Protection (m)
Product Description
Elbow
2m, IP54, Elbow(with one input and one output terminal box)(along current direction, no circuit on left side, no socket; along current direction,25A circuit on right side,no socket)
3m, IP54, Elbow(with one input and one output terminal box)(along current direction, no circuit on left side, no socket; along current direction,25A circuit on right side,no socket)
2m, IP54, Elbow(with one input and one output terminal box)(along current direction, 25A circuit on left side, no socket; along current direction, no circuit on right side,no socket)
3m, IP54, Elbow(with one input and one output terminal box)(along current direction, 25A circuit on left side, no socket; along current direction, no circuit on right side,no socket)
2m, IP54, Elbow(with one input and one output terminal box)(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side,no socket)
3m, IP54, Elbow(with one input and one output terminal box)(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side,no socket)
2m, IP54, Elbow(with one input and one output terminal box)(along current direction, 40A circuit on left side, no socket; along current direction, no circuit on right side,no socket)
3m, IP54, Elbow(with one input and one output terminal box)(along current direction, 40A circuit on left side, no socket; along current direction, no circuit on right side,no socket)
2m, IP54, Elbow(with one input and one output terminal box)(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side,no socket)
3m, IP54, Elbow(with one input and one output terminal box)(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side,no socket)
WPLTGEE0T0IP54-20
0
25
IP54
2
WPLTGEE0T0IP54-30
0
25
IP54
3
WPLTGET0E0IP54-20
0
25
IP54
2
WPLTGET0E0IP54-30
0
25
IP54
3
WPLTGEE0F0IP54-20
0
40
IP54
2
WPLTGEE0F0IP54-30
0
40
IP54
3
WPLTGEF0E0IP54-20
0
40
IP54
2
WPLTGEF0E0IP54-30
0
40
IP54
3
WPLTGEF0F0IP54-20
0
40+40
IP54
2
WPLTGEF0F0IP54-30
0
40+40
IP54
3
WPLTGFE0T0IP54-20
0
25
IP54
2
2m, IP54,Feeder box(with flexible tube)(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, no socket)
WPLTGFE0T0IP54-30
0
25
IP54
3
3m, IP54, Feeder box(with flexible tube)(along current direction, no circuit on left side, no socket; along current direction, 25A circuit on right side, no socket)
WPLTGFT0E0IP54-20
0
25
IP54
2
2m, IP54, Feeder box(with flexible tube)(along current direction, 25A circuit on left side, no socket; along current direction, no circuit on right side, no socket)
WPLTGFT0E0IP54-30
0
25
IP54
3
3m, IP54, Feeder box(with flexible tube)(along current direction, 25A circuit on left side, no socket; along current direction, no circuit on right side, no socket)
WPLTGFE0F0IP54-20
0
40
IP54
2
2m, IP54, Feeder box(with flexible tube)(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, no socket)
WPLTGFE0F0IP54-30
0
40
IP54
3
3m, IP54, Feeder box(with flexible tube)(along current direction, no circuit on left side, no socket; along current direction, 40A circuit on right side, no socket)
WPLTGFF0E0IP54-20
0
40
IP54
2
2m, IP54, Feeder box(with flexible tube)(along current direction, 40A circuit on left side, no socket; along current direction, no circuit on right side, no socket)
WPLTGFF0E0IP54-30
0
40
IP54
3
3m, IP54, Feeder box(with flexible tube)(along current direction, 40A circuit on left side, no socket; along current direction, no circuit on right side, no socket)
WPLTGFF0F0IP54-20
0
40+40
IP54
2
2m, IP54, Feeder box(with flexible tube)(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, no socket)
WPLTGFF0F0IP54-30
0
40+40
IP54
3
3m, IP54, Feeder box(with flexible tube)(along current direction, 40A circuit on left side, no socket; along current direction, 40A circuit on right side, no socket)
Feeder
Product Code
Outlet
IP
(A)
Protection
Length
(m)
Phase
Product Description
Plug
WPLTGP10L1IP54-10
10
IP54
1
L1
phase L1 (phase A) output10APlug
WPLTGP10L1IP54-20
10
IP54
2
L1
phase L1 (phase A) output10APlug
WPLTGP10L2IP54-10
10
IP54
1
L2
phase L2 (phase B) output10APlug
WPLTGP10L2IP54-20
10
IP54
2
L2
phase L2 (phase B) output10APlug
WPLTGP10L3IP54-10
10
IP54
1
L3
phase L3 (phase C) output10APlug
WPLTGP10L3IP54-20
10
IP54
2
L3
phase L3 (phase C) output10APlug
WPLTGP16L1IP54-10
16
IP54
1
L1
phase L1 (phase A) output16APlug
WPLTGP16L1IP54-20
16
IP54
2
L1
phase L1 (phase A) output16APlug
WPLTGP16L2IP54-10
16
IP54
1
L2
phase L2 (phase B) output16APlug
WPLTGP16L2IP54-20
16
IP54
2
L2
phase L2 (phase B) output16APlug
WPLTGP16L3IP54-10
16
IP54
1
L3
phase L3 (phase C) output16APlug
WPLTGP16L3IP54-20
16
IP54
2
L3
phase L3 (phase C) output16APlug
Product Code
Product Description
Accessory
WPLTGAHGB
Fixing Bracket
WPLTGACLP
Snap Clamp
WPLTGACBC
Cable Clamp
WPLTGAFXS
Fixing Clamp
WPLTGAFXB
Suspension Bracket
WPLTGAMHK
Mouse Hook
13
Catalogue Numbering System
WavePro LTG lighting busway can be ordered by catalogue number, please contact GE engineer to place order in accordance with
below catalog numbering system.
Trunking System
WavePro Busway
System
Lighting
Busway
WP
LTG
Current Rating &
Number of Outlet
(left)
Type
B: Busway
E0: along current flow, no left way
C: Terminal Unit
T0: along current flow, left 25A, no outlet
E: Flexible Elbow
(with two terminal units)
T1: along current flow, left 25A, one outlet
F: Feed Unit (with flexible pipe)
Current Rating & Number of Outlet
(right)
E0: along current flow, no right way
IP40
T0: along current flow, right 25A, no outlet
IP42
T1: along current flow, right 25A, one outlet
IP43
T2: along current flow, right 25A, two outlets
IP54
F0: along current flow, right 40A, no outlet
T3: along current flow, left 25A, three outlets
F1: along current flow, right 40A, one outlet
F2: along current flow, right 40A, two outlets
F1: along current flow, left 40A, one outlet
F2: along current flow, left 40A, two outlets
Length
T3: along current flow, right 25A, three outlets
T2: along current flow, left 25A, two outlets
F0: along current flow, left 40A, no outlet
Degree of
Protection
F3: along current flow, right 40A, three outlets
-05: 0.5m
-10: 1m
-20: 2m
-30: 3m
-xx: other non-standard length
or no length unit
F3: along current flow, left 40A, three outlets
Tap-off Unit
WavePro Busway
System
Lighting
Busway
Type
WP
LTG
P: Tap-off Unit (Plug)
Current Rating
Phase
Degree of
Protection
10: 10A
L1: L1or A Phase
IP40
-10: 1m
16: 16A
L2: L2 or B Phase
IP42
-20: 2m
L3: L3 or C Phase
IP43
-xx: other non-standard length
IP54
Accessories
WavePro Busway
System
Lighting
Busway
Type
WP
LTG
A: Accessory
Component
HGB (Fixing Bracket)
CLP (Snap Clamp)
CBC (Cable Clamp)
FXS (Fixing Clamp)
FXB (Suspension Bracket)
MHK (Mouse Hook)
GE Lighting & Industrial assumes no obligation of notice to holders of this document with respect to changes and reserves the right to explain finally for this publication.
14
Cable Length
15
REGIONAL OFFICES
BRANCH OFFICES
NORTH
Gurgaon
Chandigarh
Lucknow
GE India Industrial Pvt. Ltd.
5th Floor, Building No.7A
DLF Cyber City, DLF Phase-III
Sector 25 A, Gurgaon
Haryana – 122002
Ph: (0124) 4808000
Fax: (0124) 4226911 / 4226912
GE India Industrial Pvt. Ltd.
SCO No. 72 & 73, First Floor
Sector 8/C, Madhya Marg
Chandigarh-160008
Ph: (0172) 3982908-10
Fax: (0172) 3982905
GE India Industrial Pvt. Ltd.
101, Ace Business Center
19, Vidhan Sabha Marg
Lucknow-226001
Ph: (0522) 3203808, 3012444/666
Fax: (0522) 4045909
Bangalore
Chennai
Coimbatore
Cochin
Hyderabad
GE India Industrial Pvt. Ltd.
The Millenia, Level-6, Tower B
1 & 2, Murphy Road, Ulsoor
Bangalore-560008
Ph: (080) 41434000
Fax: (080) 41434199
GE India Industrial Pvt. Ltd.
Temple Tower, 6th Floor
476, (New No. 672) Anna Salai
Nandanam
Chennai-600035
Ph: (044) 45070470-84
Fax: (044) 45070474
GE India Industrial Pvt. Ltd.
No.36/6 & 7, 1st Floor
Ashirwad Building
D.B.Road, R.S. Puram
Coimbatore-641002
Ph: (0422) 4393520 / 4393529
GE India Industrial Pvt. Ltd.
Mayur Business Center & Motel
Chittur Road, Pullepadi Junction
Cochin-682035
Ph: (0484) 2364139
Fax: (0484) 4031400
GE India Industrial Pvt. Ltd.
5-2-45, Hyderbasti, RP Road
Near Gujarati High School
Secunderabad-500003
Ph: (040) 27543162, 66311264
Fax: (040) 66339272
Mumbai
Ahmedabad
Pune
GE India Industrial Pvt. Ltd.
361/362, Solitaire Corporate Park
M. Vasanji Road, Chakala
Andheri (E), Mumbai-400093
Ph: (022) 40101610
Fax: (022) 40101611
GE India Industrial Pvt. Ltd.
405-406, Kirtiman Complex
Kinariwala House, Behind Citibank
Off C.G. Road, Ahmedabad-380006
Ph: (079) 65427385/65427389
Fax: (079) 26460637
GE Money Financial Services Limited
Shop No. 405-410, 4th Floor
City Point, Dhole Patil Road
Pune-411001
Ph: (020) 41266999
Fax: (020) 41266109
SOUTH
WEST
1204/BUSWAYS/CAT/LTG
EAST
Kolkata
GE India Industrial Pvt. Ltd.
Horizon Building, 4th Floor
57, Chowringhee Road
Kolkata-700071
Ph: (033) 40034056
Fax: (033) 40034071
We are committed to continuous development and improvement of our products and the specifications are
subject to change without notice. For product availability and latest prices, please contact GE Sales Team.
For any further information, visit us at http://www.geindustrial.com
g and General Electric are registered trade marks of General Electric Co. USA
©
Works:
GE India Industrial Pvt. Ltd.
Plot No. 42/1 & 45/14
Electronic City - Phase II
Bangalore-560100
Ph: (080) 41113000
Fax: (080) 28528469/552
HO:
GE India Industrial Pvt. Ltd.
The Millenia, Level-6, Tower B
1 & 2, Murphy Road, Ulsoor
Bangalore-560008
Ph: (080) 41434000
Fax: (080) 41434199
Email: query@ge.com
Toll Free No:
18001024343
Customer Care:
gecustomer.care@ge.com
Download