Distribution Feeder Protection FM2 FEEDER Protection System Economical and compact feeder protection for low voltage feeders Key Benefits • Comprehensive low voltage feeder management system - Integrated feeder protection and process control in a small package • Cost effective solution - Low cost modular design • Small footprint and compact design - With or without display, fits into standard Power Control Center buckets • Ease of use - EnerVista™ compatible • Remote monitoring - via serial communications, Modbus RTU • Easy installation and integration - Door mount option • Reduced number of devices - Replaces of bi-metal overload elements, integrates timers, relays, meters, switches, indicators • Integrated trip pushbutton • Easy to read two line display Applications • Feeder protection and management system for low voltage distribution feeders • Integrated process and electrical control • Specifically designed for Power Control Centre applications Features Features Protection and Control Monitoring & Metering • Thermal overload protection • Display phase current, ground current, current unbalance, voltage, power, energy, etc. • Trip record and pre-trip values • Current unbalance • Ground fault protection • Open contactor/Welded contactor • Maintenance information • Under voltage autoreclose Communications • Outputs: 2 fixed, 1 programmable and 1 emergency shutdown • Inputs: 6 fixed, 10 programmable • • • • RS485 ModBus™ , 1200 - 19,200 bps Front Panel 11 LEDs, key pad, and 2x20 LCD display Front Panel control push buttons Includes EnerVista™ software EnerVista™ Software • EnerVista™ software - an industry leading suite of software tools that simplifies every aspect of working with GE Multilin devices • EnerVista™ Integrator providing easy integration of data in the FM2 into new or existing monitoring and control systems g Digital Energy Multilin 359 FM2 Feeder Protection System Distribution Feeder Protection Protection and Control Contactor/Circuit Breaker Failure Outputs The FM2 is available with a variety of protection and control features. FM2 can be used for fuse contactors feeders or feeders with breakers having built in trip units. The FM2 monitors the contactor/circuit breaker while performing close and open commands. If the contactor does not change status an ‘open control circuit’ or ‘welded contactor’ alarm is triggered. Thermal Overload If circuit breaker doesn’t change status a ‘breaker failed to close’ or ‘breaker failed to open’ alarm is generated. The FM2 has two output relays (A and B). Relay A and Relay B can be controlled independently for controlling a breaker. Relay A is used as close contact and Relay B is used as a trip contact for the breaker. There is also a programmable relay available on the FM2, which can be assigned to any one of the relay functions. FM2 has an emergency shutdown (ESD) relay, which can be energized externally by applying 24VDC. Thermal overload trip occurs when the thermal capacity value equals 100%. Thermal capacity used is calculated from accumulated I2t value and chosen overload curves. True RMS current sensing ensures correct response to the heating effect of harmonics. One of 3 different I2t time overcurrent overload curves may be selected from standard IEC curves. Additional Alarms The FM2 has programmable alarms to warn of a number of abnormal conditions. These include: contactor inspection, and process interlock switch open. Undervoltage Autoreclose After an overload trip, the thermal capacity value decreases exponentially to model the load cooling characteristic. An overload trip can be reset when the thermal capacity value decreases to 15%. The feeder can be automatically reclosed after a momentary power loss when this feature is enabled. When the control voltage drops below the dropout voltage the contactors are de-energized. The FM2 can initiate timers to reclose selected feeder upon the return of supply voltage. It has one instantaneous and two delayed reclose settings. If control voltage is restored within the programmed reclose time, the feeder will be reclosed immediately. If the control voltage takes longer to be restored, the FM2 can be programmed to attempt a reclose after a programmed time delay. Ground Fault Aging and thermal cycling can cause cable and equipment insulation to break down, resulting in ground faults. Ground faults can be detected by either from the residual connection of the phase CTs or from the zero sequence CT. The FM2 can trigger a trip or an alarm if the ground fault pickup level is exceeded. A time delay may be entered for time coordination of systems with several levels of ground fault detection. The FM2 has six fixed control inputs. These are used for close A and B, open, test status, and contactor A and B status. The FM2 also has 10 programmable switch inputs. Each input can have one of a number of interlock functions assigned to it. A function can be assigned to one interlock input. Monitoring and Metering The FM2 offers advanced monitoring and metering which includes: Metering The FM2 meters and displays: • RMS current of each phase • Ground fault leakage current • Phase current imbalance (%) • Power (kW) • Energy (kWhr) Functional Block Diagram BREAKER Switched Inputs ANSI Device Numbers & Functions Device Number 49/51 50G 79 52 415 - 12000 VOLTS BUS Function overload welded/open contactor earth fault undervoltage autoreclose *see ANSI Standard in catalog for a complete list • Voltage Trip Record When the FM2 issues a trip command a record is generated which includes the cause and pre-trip current values. Statistics and Maintenance FUSE The FM2 records statistical data about relay and feeder operation, allowing the user to set the interval at which routine maintenance tasks should be performed. When the times are exceeded an alarm is generated. This includes: PROG. RELAY CONTACTOR RELAY A RELAY B PHASE/LINE VT 79 ESD RELAY PHASE CT 49 51 CBCT 50G LOAD 360 24VDC INPUT CONTROL INPUTS PROCESS PLC RS485 REMOTE COMMUNICATE 1200 - 19200 BAUD FM2 FEEDER PROTECTION SYSTEM 848700A1.DWG www.GEDigitalEnergy.com • Contactor inspection: number of contactor/breaker operations after which contactor contacts must be inspected for wear FM2 Feeder Protection System User Interfaces single communication channel. The FM2 supports operation at 1200 to 19,200 bps. A RS232/485 converter module may be used to connect a personal computer to the FM2. The user can communicate with the FM2 through a variety of interfaces: Display and Control Keys The panel mount model has a large user OPEN key which opens feeder contactor/breaker. The panel mount model comes with a two-line 40 character display and additional control keys. The display and keypad can be used for local programming, showing information on alarms and trips, and displaying monitoring and metering values. Distribution Feeder Protection Models Mounting Configurations The FM2 can be ordered in either chassis mount or panel mount with display. The chassis mount model comes with any of the option models. Setpoints are loaded through the RS485 port. Indicator LEDs The panel mount with display model may be ordered with any option model. It is mounted on the front panel of the PCC with its two by 20 alphanumeric display, full keypad, and 11 status LEDs exposed to the operator for complete local viewing and setpoint programming. The setpoints can also be loaded into the relay through the RS485 communications port. The panel mount FM2 has nine status LEDs and has two additional LEDs which indicate auto mode or manual control mode. Communications The FM2 uses a ModBus® RTU RS485 connection for communication. Up to 32 FM2s can be daisy-chained together on a Models Model 712: • 120V, 50 or 60Hz AC VT input and switch input voltage rating Model 722: • 240V, 50 or 60Hz AC CT input and switch input voltage rating The panel mount with display model is the “Top of the Line” FM2. EnerVista™ Software A single PC setup software package is required to access, configure, and monitor the FM2 relay. The EnerVista™ FM2 Setup Software extracts the model number, version, and configuration parameters from the connected relay to display only the relevant data and options for the relay it is communicating with. This eliminates having to manually configure the relay within the software and provides a simple and easy to use operator user interface. The FM2 relay is supplied with Windows® based EnerVista™ FM2 Setup Software. EnerVista™ software may be run on a PC with any Windows® based operating system. The program may be used locally on the RS232 front port or remotely on the RS485 port. It provides full access to the relay data with the following features: • View relay status and actual values • View/edit settings on-line/off-line The chassis mount model is the “black box” version of the FM2. It is mounted inside the power control center (PCC). • View event recorder for trouble-shooting • Configure inputs, outputs and LEDs through configurable logic CONVENTIONAL PCC SUPERVISORY CONTROL SYSTEM CLOSE OPEN CLOSED OPEN TRIPPED MULTIWIRE CONTROL CABLE REMOTE CONTROL Cost Effective PCC Wiring with FM2. PCC WITH FEEDER MANAGER 2 SUPERVISORY CONTROL SYSTEM • Relay firmware programming for upgrades In addition, all status information such as target messages and digital input/output states may be viewed with EnerVista™ FM2 Setup Software. TWO WIRE CONTROL CABLE PLACED BY RE OPEN CLOSE CONTACTOR TRIP LOCAL PCC REPEAT FOR EACH CONTACTOR/BREAKER 120/240 VAC CONTACTOR OPEN CONTACTOR LOAD SENSOR • Utilize a configurable protection curve DIGITAL CONTROL/ MONITOR RS485 TWISTEDPAIR TO OTHER CONTACTORS IN PCC FEEDER MANAGER 2 120/240 VAC RUNNING STOPPED TRIPPED ALARM FAULT O/L E/F TRIP FIELD STOP AUTO CLOSE A SETPOINT MANUAL CLOSE B ACTUAL RELAY B PROG RELAY ESD RELAY RESET OPEN CONTACTOR RELAY A MESSAGE VALUE STORE Multilin FM2 Feeder Manager 2 807680A7.cdr www.GEDigitalEnergy.com 361 FM2 Feeder Protection System Features Front View Distribution Feeder Protection DISPLAY: 2 line, 40 character illuminated display communicates all messages in simple English for easy interpretation by users unfamiliar with unit. relay indicators: Relay A: Contactor A energized. Relay B: Contactor B energized. prog relay: User programmable relay 1 energized. esd relay: ESD Relay energized. control KEYS: Auto: Selects operation of close via communication port. Manual: Selects manual operation of feeder using close key. CLOSE A: Energize contactor A. CLOSE B: Energize contactor B. OPEN: De-energize contactors. program KEYS: ACTUAL VALUES: Press to enter actual values mode to display actual feeder values such as current, earth leakage, voltage, power, energy. SETPOINTS: Press to enter setpoint mode to alter or examine setpoints. Store: Save a newly entered setpoint. RESET: Reset the FM2 after a trip. Message: Move to the desired setpoint or actual value message. VALUE: Increment or decrement currently displayed setpoint value. status INDICATORS: CLOSED: Contactor is energized and feeder is closed. OPEN: Contactor is not energized and motor is not running. TRIPPED: Contactor is not energized. Feeder is open. The FM2 has tripped the feeder due to a fault. Normally a cause of trip message will be displayed. ALARM: One or more alarm conditions are present. Normally a cause of alarm message will be displayed. Fault: An internal fault or abnormal condition has been detected. The FM2 may need to be replaced or serviced. Rear View Supply voltage required to power theFM2 . communications RS485 2 wire serial communication port operates at 1200 – 19,200 bps for remote commands, monitoring and setpoint store. ModBus® RTU protocol. Control Power 120/240 VAC supply voltage selector switch and fuse access door. 4 relays •Relay A: •Relay B: •User programmable relay (PROG RELAY 1) • Emergency Shutdown Relay (ESD) Earth safety and surge. voltage input Phase R voltage input for voltage and power monitoring. EARTH FAULT ct input 5 amp or 50:0.025 earth fault input for residually connected phase CTs or separate core balance (zero sequence) CT. phase Ct inputs 3 isolated phase CT inputs that accept 1 amp or 5 amp CT. 362 switch inputs Opto-isolated 120 VAC live inputs for various interlock functions. The interlock inputs are fully programmable and can be assigned to such functions as setpoint access, plant interlock, test, and various others. www.GEDigitalEnergy.com FM2 Feeder Protection System Typical Wiring RESIDUAL GROUND CONNECTION 1 5A 2 CT PHASE Y 3 4 PHASE R CT B 415V R R Y 5 1A COM 5A 1A 6 7 PHASE Y CT ISOLATOR SWITCH 8 COM 5A 9 10 12 11 Y CT PHASE B 2 5A EARTH CT 3 4 5 1A COM 5A PHASE R CT 1A 6 7 COM 5A PHASE Y CT 8 9 10 PHASE B CT 12 11 1 50: 0.025 COM 1A COM 5A 2 5A EARTH CT CORE BALANCE ( ZERO SEQUENCE ) CT CT CT PHASE R PHASE Y PHASE B CONTACTOR A L1 B 1 50: 0.025 COM 1A COM 5A PHASE B CT DIRECT CONNECTION TWO PHASE CT CONNECTION CT PHASE R CT PHASE B 3 4 5 1A COM 5A PHASE R CT CT EARTH 6 1A 7 COM 5A PHASE Y CT 8 9 1A COM Distribution Feeder Protection CT PHASE R PHASE B CT L1 A L2 L2 A L3 L3 LOAD 415V 120V OR 240V * See Note 4 Vry VT VT 16 1 2 3 5A 1A COM 4 INTERLOCK INPUT 10 INTERLOCK INPUT 9 43 INTERLOCK INPUT 8 * CLOSE * 44 INTERLOCK INPUT 7 A 45 INTERLOCK INPUT 6 46 47 INTERLOCK INPUT 5 INTERLOCK INPUT 4 48 INTERLOCK INPUT 3 49 INTERLOCK INPUT 2 50 INTERLOCK INPUT 1 51 OPEN 52 CLOSE A 53 CLOSE B 54 TEST STATUS NO CONTACTOR A STATUS NO CONTACTOR B STATUS NO 55 56 57 SWITCH COMMON 58 SWITCH COMMON CONTROL VOLTAGE EARTHING SAFETY SURGE 13 7 8 5A 1A 9 10 COM 5A 11 12 50: 0.025 COM 14 N 36 37 EARTH CT 38 SERIAL 485 + 39 SERIAL 485 g RELAY A L PHASE B CT SERIAL EARTH PROGRAMMABLE SWITCH INPUTS 42 FIXED SWITCH INPUTS OPEN 6 COM PHASE Y CT PHASE R CT 41 5 5A 1A VT COM 15 RELAY B RS485 40 Multilin FM2 Feeder Protection System PROGRAMMABLE RELAY ESD RELAY 24VDC COIL COM NO COM NO 1NC 1COM 1NO 34 35 32 33 26 27 28 2NC 2COM 2NO NC 29 23 24 30 31 COM NO + - 25 21 22 PCC EARTH BUS CONTACTOR A 848704A1.DWG L AC CONTROL VOLTAGE 120/240 VAC N NOTES: 1) RELAY CONTACT STATE SHOWN WITH CONTROL POWER NOT APPLIED. 2) TERMINALS MARKED WITH " BEFORE FEEDER IS CLOSED * " MUST BE CONNECTED 3) DIRECT CONNECTION WITH NO CTs CAN BE USED FOR FEEDER FULL LOAD CURRENT BELOW 10 AMPS (TYPICALLY LESS THAN 10 HP). NOTE: CT TERMINALS RATED FOR 600V. 4) 240VAC INPUT CAN BE GIVEN TO FM2 - 722* MODELS ONLY TRIPPED FAULT CONTACTOR B AUX 1 OPEN AUX 2 4.35" (111) ALARM CUTOUT 4.13" (105) 0.13" (3) CHASSIS MOUNT CUTOUT 7.50" (191) 7.24" (184) 6 x 0.218" Dia. HOLES (6) 4.07" (103) STOPPED CHASSIS MOUNT SIDE VIEW PANEL 0.30" (7.5) 6.90" (175) 3.47" (88) 7.10" (180) RUNNING CONTACTOR A Inches (mm) PANEL MOUNT CUTOUT 0.10" (2.5) 4.17" (106) PANEL 3.95" (100) 3.47" (88) 1.0" (25) 0.35" (9) PANEL MOUNT SIDE VIEW 7.36" (187) 1.15" (29) 2.31" (59) PANEL MOUNT FRONT VIEW 1.73" (44) Dimensions BASE PLATE PROFILE FM2 Feeder Manager 2 8 x 0.078" R (2) www.GEDigitalEnergy.com 807629C5.dwg 363 FM2 Feeder Protection System FM2 Technical Specifications PROTECTION IEC OVERLOAD CURVES Trip time: Accuracy: Detection level: IEC A, IEC B, IEC C ±200 ms up to 10 sec ±2% of trip time over 10 sec ±1% of primary CT amps ground Fault Trip time Accuracy: -0 ms, +50 ms, 0.0 = <50 ms Distribution Feeder Protection UNDERVOLTAGE – supply voltage Undervoltage: 65% of nominal (120 VAC or 240 VAC) immediate reclose for maximum dip time of 0.1 – 0.5 sec or OFF delay 1 reclose for maximum dip time of 0.1 - 10.0 sec/unlimited time delay 2 reclose for maximum dip time of 0.5 - 60.0 min/off Delay reclose range: 0.2 – 300 sec Delay restart accuracy:±0.2 sec monitoring Voltage input/power reading Conversion: True RMS, sample time: 12 samples/cycle for 50Hz 10 samples/cycle for 60Hz Voltage full scale: 1.5 x VT primary Voltage accuracy: ±2% of VT primary or ±2% of reading (whichever is greater) Power accuracy: ±5% of nominal or ±5% of reading (whichever is greater) Power range: -12500kW to +12500kW Input voltage: Nominal: 120 VAC or 240 V Max: 150 VAC for 712 model 300 VAC for 722 model VT burden: 0.01 VA Phase IMbalance Range: Greater than 30% U/B trip, alarm 15% Accuracy: ±2 percentage points Trip delay: 5 sec, ±1 sec Calculation method: If IAV Ž Iflc: | IM - IAV | x 100 IAV If IAV < Iflc :| IN - IAV | x 100 Iflc Where:IAV = average phase currents IM = current in a phase with maximum deviation from IAV Iflc = motor full load current setting METERING PHASE CURRENT INPUTS Conversion: True RMS, sample time: 12 samples/cycle for 50Hz 10 samples/cycle for 60Hz Range: 0.1 – 8 x phase CT primary amps setpoint Full scale: 8 x phase CT primary amps setpoint Accuracy: ±2% of Phase CT primary amps setpoint or ±2% of reading, whichever is greater ground FAULT CURRENT INPUT Conversion: True RMS, sample time: 12 samples/cycle for 50Hz 10 samples/cycle for 60Hz Range: 0.1 to 1.0 x Phase CT primary amps setpoint (5 A secondary CT) 0.5 to 15.0 amps (2000:1 CT) Full scale: 1.5 x CT primary amps setpoint (5 A secondary CT) (15 A (2000:1 CT) Accuracy: 5 A secondary: ± 2% of full scale 2000:1 CT: ± 0.10A (0.0 to 3.99 A) ± 0.20 A (4.00 to 15.00 A) POWER SUPPLY supply voltage AC nominal: 120 VAC, range 108 – 135 VAC 240 VAC, range 216 – 250 VAC Frequency: 50/60 Hz Power consumption: 25 VA (Maximum) 7 VA (Nominal) *CE units limited to 250 V unless external fuse rated to 300 V is used. OUTPUTs RELAY CONTACTS FM2 Contactor A & B and ESD relay Voltagemake/carrymake/carrybreak continuous 0.2 sec 30 Vdc 10 A 30 A 10 A Resistive125 Vdc 10 A 30 A 0.5 A 250 Vdc 10 A 30 A 0.3 A 30 Vdc 10 A 30 A 5A Inductive125 Vdc 10 A 30 A 0.25 A (L/R = 7ms)250 Vdc 10 A 30 A 0.15 A Resistive 120 Vac 10 A 30 A 10 A 250 Vac 10 A 30 A 10 A Inductive120 Vac 10 A 30 A 10 A (PF = 0.4) 225 Vac 10 A 30 A 8A Configuration Contactor A & B – Form A ESD Relay – form C Contact Material Silver alloy (AgCdO) Max operating voltage 280 VAC, 250 VDC Minimum permissible load 5 VDC, 100 mA communications Type: RS485 2 wire, half duplex Baud rate: 1,200 – 19,200 bps Protocol: ModBus® RTU Functions: Read/write setpoints, read actual values, execute commands, read coil status, read device status, loopback test environmental Pollution degree: 2 Overvoltage category: 2 Insulation voltage: 300 V Operating temperature range:0° C to 60° C Dust and moisture rating: NEMA Type 12+12K FM2 Prog relay 1 output Voltagemake/carrymake/carrybreak 0.2 sec Resistive 30 Vdc 5 A 15 A 5A 125 Vdc 5 A 15 A 0.25 A Inductive30 Vdc 5 A 15 A 2.5 A (L/R = 7ms)125 Vdc 5 A 15 A 0.1 A Resistive 120 Vac 5 A 15 A 5A 250 Vac 5 A 15 A 5A Inductive120 Vac 5 A 15 A 5A (PF = 0.4) 225 Vac 5 A 15 A 3A Configuration Aux relay 1 — dual form C Contact Material Silver alloy (AgCdO) Max operating voltage 280 VAC, 125 VDC type tests UL: Transients: Impulse: RFI: Static: INPUTs CT inputs Phase CT (1 A) Phase CT (5 A) Earth CT (5 A) SensitiveEarth Earth Sensitive FaultCT CT(50:0.025) (50:0.025) Fault Hipot: CT input (A) 1 5 20 5 25 100 5 25 100 0.025 0.1 0.5 Burden (VA) (ž) 0.009 0.01 0.2 0.01 3.5 0.01 0.04 0.002 0.9 0.002 16 0.002 0.04 0.002 1.1 0.002 17 0.002 0.07 116 1.19 119 30.5 122 PACKAGING Max weight: 4 lbs (1.8 kg) Shipping dimensions:8.3" x 5.625" x 5.8" (211 mm x 143 mm x 147 mm) fuse type/rating 0.5 A 250 V Fast blow, high breaking capacity Withstand 1 sec x CT 5 sec x CTcontinuous x CT Phase CT (1 A) Phase CT (5 A) Earth CT (5 A) 100 100 100 40 40 40 3 3 3 6 fixed & 10 configurable inputs optically isolated. Dry contact installation WARNING: HAZARD may result if the product is not used for its intended purpose Ventilation requirements: None Cleaning requirements: None certification : cULus: 50:0.025 EARTH FAULT Input Withstand Continuous 150 mA Maximum 12 A for 3 cycles 50:0.025 input can be driven by a GE Multilin 50:0.025 CT Digital Inputs Inputs: Input Type: E83849 ANSI/IEEE C37.90.1 oscillatory/ fast risetime transients IEC 255-22-4 electrical fast transient/burst requirements IEC 255-5 5 kV impulse voltage test IEC 255-22-3 5 v/m with portable transmitter IEC 255-22-2 electrostatic discharge 1500 V, 1 min all input >30 V IEC 61010-1 E83849 UL listed for USA & Canada *Specifications subject to change without notice. Ordering FM2 * - * - * - * Base Unit FM2 Model 712 722 PD C Product Family 120V AC VT and Switch input voltage 240V AC VT and Switch input voltage Panel mount with Display Chassis mount (Black box) Visit www.GEMultilin.com/FM2 to: • View Guideform specifications • Download the instruction manual • Review applications notes and support documents • Buy a FM2 online • View the FM2 brochure 364 www.GEDigitalEnergy.com 0306-v3