The Vision To See What Others Can’t

advertisement
The Vision To See What Others Can’t
What is Critical Power Management System?
What is included within a typical CPMS?
Key Markets...
...and Stakeholders within them utilizing CPMS
ASCO’s CPMS Is Called PowerQuest
PowerQuest
Simplifies Power
Monitoring
PowerQuest® can enable you to:
• Monitor and/or control power
transfer switches, generator
paralleling switchgear, gensets,
breakers, bus bars and other
equipment
• Monitor normal and emergency
voltages and frequency and
their settings
• Review test schedules, event
logs, power reports and
trending
• Implement login and data
security using AES128-bit
encryption
• Receive automatic alerts on
system operation via e-mail,
pager, or selected system
alarms
• View current, power and
power factor
BUSINESS-CRITICAL FACILITY
ASCO POWERQUEST
CRITICAL POWER
MANAGEMENT SYSTEM
AUTOMATIC TRANSFER SWITCH
LIEBERT UPS’s
AC POWER
BYPASS-ISOLATION
TRANSFER SWITCH
LOAD BANKS
SURGE PROTECTION
PARALLELING SWITCHGEAR
FIRE PUMP CONTROLLER
GENERATORS
Major Product and Technology Refresh Combined with Project Management,
Commissioning, Service and Retrofit Capabilities Make It Easier To Deploy
ASCO PowerQuest
PowerQuest – From Components to Integrated Solution
Extremely Flexible and Convenient
Desktop
Desktop
Desktop
Desktop
Desktop
Mobile
Improves Access / Data Security
PowerQuest 5700 Rich and Easy Interface
PowerQuest 5700 Comprehensive Graphical / Tabular Overview
PowerQuest 5700 Transfer Switch Details
PowerQuest 5700 Generator Details
PowerQuest 5700 Circuit Breaker Details
PowerQuest 5700 Current Alarms (By Device or Alarm)
PowerQuest 5700 Reports Interface
PowerQuest 5700 Filterable / Printable Historical Alarms
PowerQuest 5700 Facility Messaging
PowerQuest 5700 Typical Connectivity
Breaker
Utility
24 VDC
QTY 4, 14 Awg
3P Volts/Amps
Generator
24 VDC
QTY 8, 14 Awg
3P Volts/Amps
UPS/Distribution
7000 ATS
Generator
24 VDC
QTY 8, 14 Awg
3P Volts/Amps
5160 RCU
24VDC or 120 VAC
(Requires UPS)
24 VDC
QTY 4, 14 Awg
3P Volts/Amps
19” 5702 Operator
Touch Panel
(up to 100 with
5790 Server)
24 VDC
QTY 8, 14 Awg
3P Volts/Amps
5221
Power
Manager
Units
5350 Annunciator
ATS Status Annunciation
Transfer Test
Supports 8 ATS’s
24VDC/120VAC/220VAC
7000 ATS
24VDC
19” 5702 Operator
Touch Panel
(up to 100 with
5790 Server)
5710 CPMS Essential
5350 Annunciator
19” 5702 Operator
Touch Panel
(up to 100 with
5790 Server)
• Drives 3 Remote 5702
Panels
•Supports 32 Power Devices
•Basic Monitoring and Control
•Standard Performance
Tx/Rx (pair of Fiber)
300 ATS
24VDC
5700 CPMS Servers
Note - Select One Server to install
in Centralized Office
50° to 95°F (10°C to 35°C)
5750 CPMS Professional
Essential Features PLUS: • 5 Reporting Packages
• BMS Modbus
• Drives 10 Remote
Support
5702 Panels
•Remote E-Mail
• Supports 64 Power
Alarming
Devices
• Historical Trending
5790 CPMS Enterprise
Professional Features
PLUS:
•Drives 100 5702 Touch
Panels
•Redundant Power
•Redundant Storage
5160 RCU
24VDC or 120 VAC
(Requires UPS)
To RCU and
Additional
Networked
Devices
•Redundant Processors
•Ultimate Performance
•128 Power Devices
•Expanded Storage
•Inter-facility Messaging
5160 RCU
24VDC or 120 VAC
(Requires UPS)
To RCU and
Additional
Networked
Devices
AWG Wire Size and Distance by others
Category 6 Ethernet (300 Feet Max)
Multi-Mode Fiber, 1300nm, 50/125um,
ST Connectors (6500) Feet Max
NOTES 1. This Drawing is to be used as a Model only;
Actual network architecture will depend on
equipment placement, cable length and type.
2. 5700 Series Products Operating Temperature is
50° to 95°F (10°C to 35°C) For altitudes above 2950 feet,
the maximum operating temperature is
derated 1°F/550 ft.
PowerQuest 5900 Custom
PowerQuest 5900 Capability Highlights
PowerQuest 5900 Interface
PowerQuest 5900 Typical Project Components
PowerQuest 5900 Dynamic One Line - On Utility
PowerQuest 5900 Dynamic One Line - On UPS
PowerQuest 5900 Dynamic One Line - On Emergency
PowerQuest 5900 Network
PowerQuest 5900 Continuous Availability - Network Failure Prevention
PowerQuest 5900 Power Quality Analysis
COMPARE...
Publication 3259 R2
© March, 2013
Download