NetSure® 801 LB – BZAB34807+ Rectifier Syistem -48 VDC, up to 69.6 kW/cabinet NetSure® 801 – Uninterrupted Energy at its maximum expression! Features NetSure® 801 has all you need for large -48 DCV. It has a >93%, efficiency which is important in order to decrease operating cost and be respectful with environment. Another outstanding feature is the NetSure® 801 high density of power – up to 69.6 kW by shelf – saving space for telecommunication and data products. However, the most important feature of NetSure® 801 is its high flexibility for large -48DCV centers. NetSure® 801 is designed to protect in an effective way any -48V system. Besides the above mentioned, it is necessary to add the high standards of the Emerson Network Power products. Even more, NetSure® 801 is delivered in top and bottom cabling configurations and a wide selection of distribution units . It may use large as well as small disyuntores and fuses. There is a solution for each necessity. The batteries protection also comes in different sizes. Many small batteries or a few large batteries can be used, depending on the center and application requirements. Batteries disconnection is available in order to protect batteries against deep discharges. All the NetSure® 801 systems come with AC series protection (one breaker by rectifier). Description Introducing NetSure® 801, a high capacity DC power System within the Emerson Network Power successful NetSure® family. With the NetSure® 801, a new DC power system has been created, “best in class” for all the -48V telecommunications and data centers. The most recent design Controller NetSure® 801 is equipped with an advanced control unit, ACU. It has all the characteristics and functions necessaries for a -48V large center. Adjustments and supervision can be carried out through a Web interface or directly in the control unit. The controller incorporates advanced battery test functions, batteries capacity prediction and events registry. It has SNMP protocol and a great number of alarm relays. When it is necessary, the controller can be used as plant manager with the Emerson Network Power SM modules. The SM modules supervises advanced AC registry, cell strain and batteries block, robbery alarms, fire alarms, refrigeration equipment and much more. All the information is presented through the Web interface and Example of Top Cabling Configuration 1 Load Distribution Unit 2 Battery Distribution Unit 3 Alternate Current Distribution Unit R48-5800 Rectifier Rectifiers in the NetSure® 801 system are three phases design with high density of power and high efficiency (>93%). Other characteristics of the R48-5800 are its pluggable connection design and weight of only 8kg, making the systems installation and development easier. Rectifier also shows a low THD level (<5%) and a wide input voltage. Total output power, 5800 W, is available in a 305-530 ACV range!. Technical Specifications AC Input Input voltage, nominal 380 – 480 AC V, three phases (3F+PE) Input voltage, allowed variation from 260 to 530 AC V (total output power between 305-530 AC V) Line frequency 45 Hz – 65 Hz DC Output System nominal voltage -48 V DC Adjustable range for operating voltage from -42 DC V to -58 DC V Output power, system 348 kW (V output ≥ -48 V CC) Output power, rectifier 5800 W @ V output > 48 V CC Monitoring Control Dry contact alarms and outputs. Remote management by Ethernet Enable integration with ENEC system via EEM protocol gateway, internal Web Server, SNMP, SOC, SOC/TPE, EEM and Telnet. Remote management by RS232, YDN23, SOC and EEM protocols. Visual indications. Green LED: Normal operation Yellow LED: Observation or urgent Red LED : Critical System Environmental Specifications Operating temperature range from 0 °C to + 45 °C (total power up to + 40 °C) Operating relative humidity range Audible noise < 90% 55 dB(A) @ <25 °C / 60 dB(A) @ <50 °C CEM EN 300 386:2001 Class A, FCC part 15, class A Safety System Mechanical Specifications Dimensions (HighxWidexDeep) Weight Distributed system: Cabinets include rectifiers, Battery units and load distribution System Units AC connection IEC 60950, EN 60950 2200 x 600 x 600 mm <250 kg by cabinet All the cabinets with rectifiers include an AC panel (a three phases breaker by rectifier ) Rectifier/Power Supply Unit R48-5800 (refer to own rectifier features sheet) Distributed system Controller Up to 12 rectifiers by cabinet ACU, advanced control unit (refer to own ACU features sheet) Distribution Units Load distribution units for breakers Low Ohmic Load distribution units for breakers High Ohmic Load distribution units for fuses NH3 27 x 18 mm positions, from 2 to 63A, unit total capacity 400A 27 x 18 mm positions, from 2 to 16A, unit total capacity 300A 6xNH3, up to 630A by fuse, total capacity 1200A Battery distribution units for fuses NH3 4xNH3, up to 630A by fuse, total capacity 1200A, optional LVD with 1500A “latch” type Alternate current distribution unit With indivual breaker by rectifier, optional surge protection, bars Temperature probe With 3 and 10 meters cable contractor Emerson (NYSE: EMR), based in St. Louis, is a global leader in the technology and engineering integration to provide its clients with innovative solutions through its network power, process management, industrial automation, climate technologies and appliance and tools divisions. For more information, visit: Emerson.com. Emerson Network Power, a subsidiary of Emerson (NYSE:EMR), is the global leader in enabling Business-Critical Continuity™ from mains to point of use for telecommunication networks, data centers, health care and industrial facilities. Emerson Network Power provides innovative solutions and expertise in areas including AC and DC power and precision cooling systems, Embedded computing and power systems, embedded racks and shelves, power switching and controls, monitoring, and connectivity. Emerson Network Power offers and installs globally all its solutions by means of its local service technicians. For more information about Emerson Network Power’s full suite of solutions, specifically designed to preserve the communications network infrastructure, including the NetXtend™ outside plant shelves, NetSure® DC power systems, and turnkey services, visit: EmersonNetworkPower.com/EnergySystems. Learn more about Emerson Network Power products and services at: EmersonNetworkPower.com. This publication is issued to provide detailed information which may not be used, applied or disclosed for any purpose, or be part of any order or contract or be considered as a statement related to concerned products or services. Emerson (unless otherwise is written specified by Emerson Network Power Energy Systems AB), Emerson Network Power Energy Systems AB, reserves the right to modify without notice the specifications, design or supplying conditions of any product or service. Emerson®, Emerson Network Power™, Business-Critical Continuity™, NetSpan™, NetReach™, NetXtend™ and NetSure® are trademarks of Emerson Electric Co. and/or one of its subsidiaries. Emerson Sistemas de Energia Ltda Av. Emb. Macedo Soares 10735, 5° andar Vila Anastácio 05095-035 São Paulo - SP Telephone: +55 11 3618 6600 Fax: +55 11 3618 5902 Web: www.emersonenergy.com/br