Telecom Network Solutions for Business Critical Continuity Tailored Solutions for Telecommunication Networks Emerson Network Power Telecom System Solutions We Know The Importance Of Achieving Protection For Today…And Planning For Tomorrow All telecom installations require DC power systems. They consist of a combination of converters, distribution, controllers and back up, match designed to meet any technical specifications. This is something Emerson Network Power does well. So well in fact, that in 2004 our DC power systems sales were more than the sales of our three largest competitors - combined. No Matter How Deep Your Protection Needs To Be, We Have The Expertise To Make It Happen The Emerson Network Power DC Power Systems portfolio is supported by vast resources. Design centers on five continents make sure our systems are optimized for different requirements and needs in the different parts of the world. Manufacturing facilities, supply management and logistics experts on as many continents optimize sourcing and delivery flows for the best cost/lead-time combination to meet our customers needs. Our global network of Emerson Network Power offices makes us easy to reach. We are local, globally. Whatever you are facing, chances are almost certain they have already experienced a similar require needs. The will to use them in supporting our customers is part of our business philosophy. Emerson, the world leading supplier of DC power systems, has the power to do it. So Much More Than Just DC Power In this catalogue you find not only our very comprehensive DC power system portfolio. You will also find many other products, services and capabilities, enabling us to tailor the optimal solution for your telecom infrastructure. Whether you are looking for a well-defined solution, or a full strength partner to assist you every step of the way, we have what it takes to fulfill your requirements. And through our global organization we have it close to where you need it. Welcome to Emerson Network Power. The global source for local solutions. 4 Our Range Of Telecom Solutions DC POWER SYSTEMS We have a DC solution to meet every need 2 BATTERIES Extending Telecom Power Reliability 18 MONITORING Manages your power equipment in real time 18 ENCLOSURE SOLUTIONS Equipment enclosures with multi-dimensional flexibility PRECISION AIR CONDITIONING Manage equipment heat 30 38 The DC Systems Portfolio Emerson Network Power’s DC systems offering include a wide span of products. From small, embedded systems for applications like access nodes or microwave repeaters, to large stand-alone systems for Telecom central offices, business communications centers, or similar applications. A wide selection of DC systems is a must for anybody with the ambition of being a major supplier in this field, allowing optimization for varying requirements in different parts of the world. On these pages you find the worlds most comprehensive portfolio of DC power solutions. It offers the best of two worlds in combining global scale and resources with local presence and adaptations to regional and local requirements. 2 There Is A DC Solution To Meet Every Need ACTURA ® is Emerson Network Power’s line of DC Products MINI POWER SYSTEMS DC Power stand-alone systems recommended for applications of <3kW ACTURA ® Optima 4810 ACTURA ® Optima 4825 ACTURA ® Optima 4830 ACTURA ® Optima 4845 SMALL POWER SYSTEMS DC Power stand-alone systems recommended for applications of 3-10 kW ACTURA ® Optima 48130 ACTURA ® Optima 48300 ACTURA ® Flex 48330 MEDIUM POWER SYSTEM DC Power stand-alone systems recommended for applications of 10-40 kW LARGE POWER SYSTEM DC Power stand-alone systems recommended for applications of 30 kW and up ACTURA ® Flex 48800 ACTURA ® Durus 481500 24V POWER SYSTEM ACTURA ® Flex 241200 DC-DC SYSTEM ACTURA ® C24/48-1200 REPLACEMENT PROGRAM ACTURA ® Blue ACTURA ® Ranger ACTURA ® Durus 48400 ACTURA ® Durus 48600 ACTURA ® Flex 48701 3 ACTURA ® Optima 4810 Mini Power System Key Features: 1 U Height and designed for 19” racks Integrated LVD and priority load Actura Optima 4810 Nominal system voltage: System rated output power @ - 54 V: Rectifier rated output power @ - 54 V: AC input range: Environmental data: EMC Safety Subrack dimensions (H x W x D): 4 Key Benefits: Space efficient solution with all functions integrated -48 V 600 W 300 W (constant current) 90-264 V AC EN 300386 Class B EN 60950 42 x 438 x240mm DC Power ACTURA ® Optima 4825 Mini Power System Key Features: ETSI or 19” shelves with front access Available with transient limiting distribution and LVD Premounted and tested for fast installation Actura Optima 4825 Nominal system voltage: System rated output power: Rectifier rated output power: AC input range: Environmental data: EMC Safety Subrack dimensions (H x W x D): Dimensions (H x W x D): Key Benefits: Reliable power supply for all kinds of small 48 V applications Reliable DC supply to equipment due to transient limiting distribution - 48 V 1800 W 300 W (constant power) 90-140 V AC or 180-288 V AC EN 300 386 Class B IEC 60950, UL 1950, EN 60950 150 x 450 x 175mm 300 x 450 x 175mm 5 ACTURA ® Optima 4830 Mini Power System Key Features: 2 U Height and designed for 19”racks Integrated AC distribution, LVD and priority load Remote monitoring and dry contacts Actura Optima 4830 Nominal system voltage: System rated output power @ - 54 V: Rectifier rated output power @ - 54 V: AC input range: Environmental data: EMC Safety Subrack dimensions (H x W x D): 6 Key Benefits: Space efficient solution with all functions integrated -48 V 1700 W 850 W (constant current) 90-290 V AC EN 300 386 Class A EN 60950, UL 60950 88 x 483 x 350mm DC Power ACTURA ® Optima 4845 Mini Power System Key Features: 3 U Height and designed for 19”racks Remote monitoring and dry contacts Integrated AC distribution, surge protection, LVD and priority load Actura Optima 4845 Nominal system voltage: System rated output power @ - 54 V: Rectifier rated output power @ - 54 V: AC input range: Environmental data: EMC Safety Subrack dimensions (H x W x D): Key Benefits: Space efficient solution with all functions integrated on one shelf Robust and well proven design for tropical climates Provides reliable DC supply - 48 V 2550 W 850 W (constant current) 90-290 V AC EN 300 386 Class A EN 60950, UL 609 50 Rectifier 110 V AC version 133 x 465 x 360mm 7 ACTURA ® Optima 48130S Small Power System Key Features: Narrow cabinet: 160 mm wide Available with rectifiers for 48V supply or DC/DC (+24VDC/ 48VDC) LVD and priority load, advanced or basic monitoring Actura Optima 48130S Nominal system voltage: System rated output power: Rectifier rated output power: AC input range: DC input range: Environmental data: EMC Safety Dimensions (H x W x D): 8 Key Benefits: Existing sites can easily be used for GSM/WCDMA co-siting or expansions due to the 160mm wide cabinet and DC/DC converter Cost-efficient solution: existing surplus capacity of +24V and battery capacity can be used as a result of the DC/DC converter solution - 48 V 7200 W 1200 W (constant power) 90-275 V AC 19.5-30 V DC FCC part 15 Class B, EN 300 386, EN 55022 Class B IEC 60950, UL 60950, EN 60950 1700 x 160 x 400mm DC Power ACTURA ® Flex 48300 Small Power System Key Features: Flexible configuration easy to expand – wide range of configuration possibilities: number of distribution slots, size of breakers, supervision alternatives, shelf applications, cabinets, battery backup and more LVD and priority load Full power at - 40°C to + 75°C Actura Optima 48300 Nominal system voltage: System rated output power @ -54 V: Rectifier rated output power: AC input range: Environmental data 48300: EMC Safety Subrack dimensions (H x W x D): Key Benefits: Cost-effective for every need and future-proof – flexible and scalable system that can be configured to suit current needs, without limiting future expansion possibilities -48 V 6 kW 1500 W (constant power) 83-290 V AC FCC part 15 class B, EN 300 386, EN 55022 class B IEC 60950, UL 60950 (rectifier), EN 60950 134x450x320 mm 9 ACTURA ® Flex 48330 Small Power System Key Features: Provides up to 16kW in one cabinet together with up to 660Ah of batteries Front access and top cabling design for installation and maintenance Low voltage battery disconnect to protect batteries Utilizes UL approved rectifier R48-2900/ R48-3200 Flexible battery back up system with up to 5 battery strings in one cabinet and a wide range of configuration Easily expandable with more power or/and feature when new need arise Hot swap of rectifier units Actura Optima 48330 Nominal system voltage: Output Power Rectifier rated output power: AC input range: Environmental data 48300: EMC Safety Dimensions (H x W x D): 10 Key Benefits: Optimized for base station power applications Offers advanced features, intelligent battery monitoring, remote monitoring and low voltage battery disconnect The cabinet comes fully equipped with integrated AC and DC distribution Cost-effective for every need Future-proof, flexible and scalable system that can be configured to suit current needs for future expansion possibilities -48 V 16 kW 3200 W 85-290V AC EN 55022 Class B CE, UL EN60950:1992, UL1950 600X600X2000mm or 600X400X2000mm or 600X400X700mm DC Power ACTURA ® Durus 48400 and 48600 Medium Power System Durus 48400 Key Features: Wide input voltage window Integrated AC distribution, surge protection, LVD and priority load Actura Durus 48400 and 48600 Nominal system voltage: System rated output power @ - 54 V: Rectifier rated output power @ - 54 V: AC input range: Environmental data: EMC Safety Cabinet dimensions (H x W x D): Durus 48600 Key Benefits: Rectifier module adopts DSP technology Power density up to 15.8W/in3 Wide input voltage range (85V - 290V), adaptable to various grids Front access and space efficient. System can be positioned next to wall Full battery management function that expands lifetime Hot swap and online manitenance -48 V 23.7 kW and 35.6 kW 2970 W (constant current) 85-290 V AC EN 55022 EN 60950 1600 x 600 x 600mm or 2000 x 600 x 600mm 11 ACTURA ® 48701 Medium Power System Emerson’s new Power system ACTURA® 48701 is based on a concept with modular building blocks designed to meet present and future capacity and functionality needs. The concept allows the regional configuration center to easily and quickly “put together” an almost unlimited number of configurations Key Features: 400 x 600 mm or 600 x 600 mm cabinets High power density rectifiers Actura Optima 48701 Nominal system voltage: System rated output power @ -54 V: Rectifier rated output power: AC input range: Environmental data: EMC Safety Subrack dimensions (H x W x D): 12 Key Benefits: Floorspace saving Large space for batteries in main cabinet giving long backup time from a single rack -48 V 38.4 kW 3200 W (constant power) 85-290 V AC EN 300386-2001, class B, FCC part 15 class B IEC 60950, EN60950 Flexible DC Power ACTURA ® Flex 48800 Large Power System Key Features: · High power density Non-priority load disconnection/ reconnection Remote control and supervision via web server Actura Flex 48800 Nominal system voltage: System rated output power @ - 54 V: rated output power: range: Environmental data: EMC Safety Cabinet dimensions (H x W x D): Key Benefits: Footprint cost through high power density Low battery capacity needed thanks to non-priority load disconnect function Fewer site visits and related maintenance costs due to remote control and supervision Easily expandable system - 48 V 40.5 kW (Version 1) / 42 kW (Version 2)Rectifier 2700 W (Version 1) / 6000 W (Version 2)AC input 120-295 V AC (version 1) / 208-511 V AC (Version 2) FCC part 15 Class B, EN 300 386-2, EN 55022 Class B IEC 60950, UL 60950, EN 60950 1800 x 600 x 400mm, or 2200 x 600 x 400mm 13 ACTURA ® Durus 481500 Large Power System Key Features: Wide input voltage window and enhanced AC surge protection Separate cabinets for AC supply, rectifiers and DC supply Actura Durus 481000 Nominal system voltage: Operating Voltage Range Rectifier rated output power AC input range: Environmental data: EMC Cabinet dimensions (H x W x D): 14 Key Benefits: Easy to expand because of bulk architecture Cost-effective solution - 48 V -42 Vdc to -58 Vdc 5800 W 304-456 V AC EN 55022 Class A 2000 x 600 x 600mm or 2000 x 800 x 600mm DC Power ACTURA ® Flex 241200 24V Power System Key Features: High power density Priority load disconnection/ reconnection Remote control and supervision via web server Actura Flex 241200 Nominal system voltage: System rated output power: Rectifier rated output power: AC input range: Environmental data: EMC Safety Cabinet dimensions (H x W x D): Key Benefits: Low real estate cost through high power density Low battery capacity needed thanks to priority load function Fewer on-site visits and related maintenance costs due to remote control and supervision Easily expandable system +24 V 32,4 kW 2700 W (constant power) 120-295 V AC FCC part 15 Class B, EN 300 386-2, EN 55022 Class B IEC 60950, UL 60950, EN 60950 1000 x 600 x 400mm, 1800 x 600 x 400mm, or 2200 x 600 x 400mm 15 ACTURA ® C24/48-1200 DC/DC Power System Key Features: · For embedded or stand alone applications Compact design Up to 10 units in one system Actura C24/48-1200 Nominal system output voltage: System rated output power: Converter rated output power: DC input range: Environmental data:EMC Safety Subrack dimensions (H x W x D): 16 Key Benefits: Easy to package into existing applications Relay alarm outputs for easy supervision - 48 V 14.4 kW 1200 W (constant power) 21, 5-29 V DC EN 300 386:2001 class B, FCC part 15 class B IEC 60950, UL 60950, EN 60950 132.5 x 482.6 x 327 mm (19”) or 132.5 x 584.2 x 327 mm (23”) DC Power ACTURA ® Blue 48450 ACTURA ® Ranger 170K Replacement Program Ranger 170K Key Features: Change out of rectifiers and controller in existing DC power cabinet Change out on live system with all distribution cables untouched Actura BLUE 48450, ACTURA Ranger 170K Nominal system voltage: System rated output power: Rectifier rated output power: AC input range: Environmental data: EMC Safety Blue 48450 Key Benefits: Future-proof change out Uninterrupted expansion -48 V Determined by existing power system 2700 W (constant power) 120-295 V AC FCC part 15 class B, EN 300386, EN 55022 class B IEC 60950, UL 1950, EN 60950 17 Batteries The Battery program comprises of two different ranges, Excellence and Duration. Whether the prime concern is energy density, reliability, cost or a combination of these – there is always a suitable choice available. Besides having developed these battery ranges a close cooperation with several world-leading battery manufacturers exist. This unparalleled variety of batteries realizes true customer adaptation possibilities. A wide selection of battery racks is available, depending on different preferences for seismic shock resistance and height. Monitoring Systems The monitoring system developed by Emerson Network Power monitors and manages all kinds of power equipment, air-conditioner and the environment in the communication sites in real time, so as to ensure the reliable operation of telecom system and provide effective means and tools for unattended or less-attended guarding. Emerson Network Power monitoring system has developed into a comprehensive series of products including the hardware, software, video and transmission products and the system can be configured very flexibly to meet the different requirements of different regions, different management, different sites and different transmission equipment. 18 Extending Telecom Power Reliability BATTERIES EXCELLENCE (EB SERIES) DURATION (T-SERIES) MONITORING SYSTEMS PSEM Used for monitoring the power equipment and Environment in telecom site SCU Provides detailed information and alarms regarding the status of the Telecom site’s power plant ACU Collects and present detailed information and alarms related to the Telecom site’s power plant, diesel gensets, battery backup, fans, fire detection system, doors and other auxiliary equipment SM1C / SMBAT SM2B / SMIO SM6 / SMAC 19 Excellence (EB Series) Battery Range Key Features: Exceptional volumetric energy density (>100 Wh/L) Manageable weight and true front access Designed for lifetime: >10 years 400/600 mm rack depth Available in flame retardant and non-flame retardant Excellence (EB Series) Battery blocks: Voltage range: 20 Key Benefits: Saves substantial floor space Saves costs with fewer battery racks and lower site rent Reliable operation despite many AC-mains failures Ease of installation Lower costs for replacements 100 Ah /12 V, 120 Ah /12 V, 200 Ah / 6 V 6 & 12 V Batteries Duration (T-Series) Battery Range Key Features: High volumetric energy density Designed for lifetime: >10 years True front access Available in flame retardant and non-flame retardant Duration (T Series) Battery blocks: Voltage Key Benefits: Saves both floor space, battery racks and site rent Reliable operation despite many AC-mains failures Lower costs for replacements 200 Ah, 300 Ah, 400 Ah, 500 Ah, 650 Ah, 800 Ah, 1000 Ah, 1600 Ah, 2000 Ah, 3000 Ah 40 Ah /12 V, 100 Ah /12 V, 165 Ah / 12 V 2V, 12V 21 PSEM Power Equipment and Environment Monitoring System Features of System: Stable and Reliable Monitoring in Real-time Automatic and periodic checking, fault alarm, automatic troubleshooting, automatic notification of alarms, automatic recording and automatic selfdiagnosis Flexible Networking Being able to use transmission resources such as CE1, IP, DDN/LL, PSTN, ISDN and WAN to form a network Comprehensive Monitoring Platform with Perfect Functions Seamless integration of video and data monitoring systems that share the same transmission and data management platform Management System Supporting Continuous Improvement of Maintenance Provide analysis data for maintenance, improving maintenance efficiency and reducing the maintenance cost 22 Monitoring System Architecture The PSEM monitoring system consists of Supervision Center, Supervision Station and Supervision Unit. It monitors and manages the power equipment and environment in telecom sites. The system has twolevel or three-level architecture. System Functions Reasonable system architecture design ensures the real-time monitoring capability as well as the powerful interfacing capability Objects under monitoring include the equipment such as HV and LV distributions, power supply, air-conditioner, diesel generator, battery and UPS, and include the equipment room’s environment information, such as the temperature, humidity, flood, smoke, access control and video system MDI (multi-document-interface) makes it easier for the user to browse the data and alarm information State-of-art and easy-to-use tables and HMI(human-machine interface) 23 SCU Monitoring Range Key Features: Provides detailed information and alarms regarding the status of the Telecom site’s power plant Key Benefits: Maintenance and site visits can be carried out more cost and time effectively if it is based on the information provided by the SCU High quality failure information - due to intelligent alarm setup through using PLC True hot plug installation of controller unit - thanks to simplified communication cable connection installation to a separate connection board Quick failure analysis – owing to storage of the 200 latest alarms SCU Power supply voltage: External communication: Analog inputs: Digital inputs: Digital outputs: Environmental data: EMC Safety Dimensions (H x W x D): 24 19 to 60 V DC RS232 1 DC system voltage,1 ambient & battery temp., 2 system current 8 alarms/events 8 relay outputs EN 300 386:2001 class B, FCC part 15 class B IEC 60950, EN 60950, UL 60950 87 x 85 x 287 mm / 3.35 x 3.38 x 11.3 inches Monitoring ACU Monitoring Range Key Features: The ACU can, together with different supervision modules collect and present detailed information and alarms related to the Telecom site’s power plant, diesel gensets, battery backup, fans, fire detection system, doors and other auxiliary equipment The information and alarms can be displayed by means of a web browser Key Benefits: Maintenance and site visits can be carried out more cost and time effectively if it is based on the information provided by the ACU High quality failure information - due to intelligent alarm setup through using PLC True hot plug installation of controller unit - thanks to simplified communication cable connection installation to a separate connection board Quick failure analysis – owing to storage of the 400 latest alarms Functionality can be expanded by adding SM units ACU Power supply voltage: External communication: Analog inputs: Digital inputs: Digital outputs: Environmental data:EMC Safety Dimensions (H x W x D): 19 to 60 V DC RS232 , Ethernet, HTTP, SNMP 1 DC system voltage, 2 ambient & battery temp., 2 system current 8 alarms/events 8 relay outputs EN 300 386:2001 class B, FCC part 15 class B IEC 60950, EN 60950, UL 60950 87 x 85 x 287 mm / 3.35 x 3.38 x 11.3 inches 25 SM1C/SM BAT Monitoring Range Key Features: · Lower maintenance cost related to battery backup Higher availability thanks to automated battery backup test and detailed information and alarms from the battery backup SM1C / SMBAT Power supply voltage: External communication: Analog inputs: Digital inputs: Digital outputs: Environmental data: EMC Safety Dimensions (H x W x D): 26 18 to 60 V DC RS232 25 cell/block voltages, 1 total battery voltage, 4 configurable 8 alarms/events 2 relay outputs EN 300 386:2001 class B, FCC part 15 class B IEC 60950, EN 60950, UL 60950 150 x 300 x 43 mm / 5.9 x 11.8 x 1.7 inch Monitoring SM2B/SM IO Monitoring Range Key Features: Lower maintenance costs related to equipment monitored and/or controlled by SM IO Higher availability thanks to remote monitoring and control of site equipment SM2B / SMIO Power supply voltage: External communication: Digital/Analog inputs: Digital outputs: Environmental data: EMC Safety Dimensions (H x W x D): 18 to 60 V DC RS232 7 digital analog inputs, 5 analog inputs, 1 AC frequency 3 relay outputs EN 300 386:2001 class B, FCC part 15 class B IEC 60950, EN 60950, UL 60950 150 x 300 x 43 mm / 5.9 x 11.8 x 1.7 inch 27 SM6/SM AC Monitoring Range Key Features: Lower maintenance cost related to AC units Higher availability thanks to automated standby alternator tests and AC alarms SM6 / SMAC Power supply voltage: External communication: Analog inputs: Digital inputs: Digital outputs: Environmental data: EMC Safety Dimensions (H x W x D): 28 18 to 60 V DC RS232 3 mains/phase voltage, 3 phase current, 1 battery voltage, 1 temperature, 1 network frequency, 3 apparent powers, 3 active powers, 3 reactive powers, 3 current distortions, 1 energy 12 alarms/events 4 relay outputs EN 300 386:2001 class B, FCC part 15 class B IEC 60950, EN 60950, UL 60950 150 x 300 x 43 mm / 5.9 x 11.8 x 1.7 inch 29 Enclosure Solutions Network Power Enclosures Outdoor enclosures are used for a variety of applications in telecommunications, transmission and data networks. Different systems configurations are integrated into the Network Power Enclosure for scalable purpose built solutions. A Building Practice that fits every need Network Power Enclosures are of a modular construction featuring lightweight aluminum framing and composite panels to provide both dimensional and functional flexibility. Combinations of front and side access doors gives full configuration freedom. Whatever your needs - the enclosure to match them is here. Complete Enclosure flexibility The Network Power Enclosure offers a multi dimensional flexibility in all physical dimensions, visual appearance, and level of mechanical protection for intrusion, vandalism, fire, or even bullets. The flexibility secures an optimal solution for each application. 30 The Network Power Enclosure Program BTS ENCLOSURES Space-efficient outdoor enclosure integrated with power, climate and all Necessary Telecom infrastructure POWER ENCLOSURES and UPS ENCLOSURES Comes with an integrated power system, Batteries and climate system required to support a new or an extended Telecom site BATTERY ENCLOSURES The ideal choice when a reliable and space efficient battery back-up is needed. ACCESS ENCLOSURES An outdoor enclosure especially suitable ForWireline access networks available in Flexible dimensions for any type of Customer configuration. TRANSMISSION ENCLOSURES Emerson comes with an integrated power system, batteries and climate system required to support the transmission equipment 31 The Complete Solution Network Power Enclosures provide a protected environment for the vital electronics inside. This includes power supply, power conditioning and back-up, climate control, burglar protection, supervision and control,etc. Customer equipment DC power supply Battery back-up Lighting protection Surge suppression Climate control Cable management Earthing Others 32 Enclosure Solutions BTS Enclosures Space Efficient Outdoor Enclosure BTS enclosures are space-efficient outdoor enclosures integrated with power, climate and all necessary telecom infrastructure. They are adapted to house one or more indoor BTSs for GSM/UMTS/CDMA/ WCDMA -- from any BTS equipment vendor. Main Advantage and Benefits: Integration of indoor BTSs into Emerson’s BTS Enclosure eliminates the need of specific outdoor BTSs Allows co-location of different types of BTS:s regardless of equipment vendor or network types Increased site capacity with up to 50% - when using the same footprint as proprietary outdoor enclosures from BTS equipment vendors Emerson’s Network Power Enclosures use the same building blocks, building practice, and supply chain process on all continents — which safeguards the homologation consistency on all markets Less needs for new building permits when upgrading existing sites by adapting the enclosure footprint to an already available foundation 33 Power Enclosures And UPS Enclosures Supports a New or Extended Telecom Site The Power and UPS Enclosures from Emerson come with an integrated system, batteries and climate system required to support a new or an extended Telecom site. The Power and UPS Enclosures are often used together with BTS Shelters to free up space in an existing shelter for additional Telecom equipment. They are also used to extend existing Enclosure based sites. Main Advantage and Benefits: Facilitates site-specific configurations - thanks to flexibility in footprint/size, power capacity, backup time, climate control capacity, and supervision functionalities Installation of additional power capacity and battery-backup on existing sites without any risk of jeopardizing the operation of the equipment it is to feed Free up floor space on existing shelter sites to house more Telecom equipment Optimized battery backup-time and lifetime thanks to smart climate control and reliable hydrogen gas ventilation 34 Enclosure Solutions Battery Enclosures Reliable and Space Efficient Battery Back-Up Solution The easily installed outdoor Battery enclosures from Emerson come with integrated temperature control adapted to the particular environmental conditions of the site and allow complete adaptation to available installation footprint/space. This makes them the ideal choice when a reliable and space efficient battery back-up is needed. Main Advantage and Benefits: Facilitates site-specific configurations - thanks to flexibility in footprint/size, shielding material, backup time, climate control capacity, and supervision functionalities Installation of additional battery-backup on existing sites without any risk of jeopardizing the operation of the equipment it is to feed Less need for new building permits when upgrading existing sites by adapting the enclosure footprint to an already available foundation Optimized battery backup-time and lifetime thanks to smart climate control and reliable hydrogen gas ventilation 35 Access Enclosures Suitable for Wireline Access Networks Access Enclosures from Emerson are outdoor enclosures especially suitable for wireline access networks, and are available in flexible dimensions for any type of customer configuration. The enclosures normally have two or three compartments with separate access, and come integrated with all the required telecom infrastructure and the installation space necessary for the customer equipment. Main Advantage and Benefits: Separate access - the enclosure can be equipped with two or three separate compartments for different service personnel access Simplified site acquisition — due to complete adaptation of the Access Enclosure’s footprint/dimensions to available installation foundation/space Homologation consistency on all markets and reduced variety of spare parts — as a result when using the same building-blocks, building-practice and supply chain process on all continents Facilitates site-specific configurations - thanks to flexibility in footprint/size, shielding material, backup time, climate control capacity, and supervision functionalities 36 Enclosure Solutions Transmission Enclosures Reliable and Space Efficient Transmission Solution Transmission Enclosures from Emerson comes with integrated power systems, batteries, and climate systems required to support the Transmission equipment. This makes them the ideal choice for a reliable and space efficient Transmission solution. Main Advantage and Benefits: Facilitates site-specific configurations - thanks to flexibility in footprint/ size, power capacity, backup time, climate control capacity, and supervision functionalities Emerson’s Network Power Enclosures use the same building blocks, building practice, and supply chain process on all continents — which safeguards the homologation consistency on all markets Optimized battery backup-time and lifetime thanks to smart climate control and reliable hydrogen gas ventilation 37 Precision Air Conditioning Every operation of your Telecom System depends upon the instant around-the clock availability of computers, servers and other electronic systems. If they aren’t working, neither is your company. Unfortunantely, every piece of this equipment your company possesses produces heat. And if you don’t get rid of the heat, you are going to have problems. The first step in taking control of this situation is to understand the threats to your system reliability – and exactly what you can do about them. No one knows more about precision cooling than Emerson Network Power. Our precision cooling business started back in 1965 with the Liebert product line. Our precision cooling technology has been proven in thousands of critical data centers around the world. In fact there are Liebert precision air conditioning systems in the field that have been in constant use for over 30 years -- a purchase that has spanned many generations of computers. These products are recognized as the world’s standard for reliable operation. 38 Liebert Datamate For Small Equipment Rooms Applications • Mobile base stations and control centers • Outdoor equipment rooms • Microwave/Satellite Earth Stations • Paging rooms • SMS centers • Network management centers • Small computer rooms Features • High sensible cooling capacity and energy efficient. Saves 20-30% energy as compared to “comfort” air conditioner • Provides constant temperature and humidity, high air flow rate and low enthalpy difference to meet specific reqirements of computer rooms • COPELAND compliant scroll compressor provides high reliability, efficiency and lifespan with maximum • Large LCD display, password protection and self diagnosis • Wide input voltage range, phase loss protection, phase order detection and automatic startup when utility is recovered • Standard port for monitoring equipment • Flexible and automatic switchover and alternative operation between master and slave • Low noise levels Technical Data Model DataMate 3000 Indoor model Outdoor model L x W x H(mm) Weight(kg) Remark DME07M 600 550 1900 124 7kW DME12M 600 550 1900 135 12kW DMC07W 702 408 626 30 7kW DMC12W 702 408 1239 48 12kW 39 Liebert Intelecool Packaged for Telecommunications Shelters Applications • Mobile base stations and control centers • Outdoor equipment rooms • Microwave/Satellite Earth Stations • Paging rooms • SMS centers • Network management centers • Small equipment rooms Features • Compliant scroll compressor • Factory packaged unit • Fully serviceable from outside • High efficiency filter • Top or bottom supply air flow 40 Precision Air Technical Data MODEL ET023A ET035A ET047A ET059A NET CAPACITY DATA BASED ON 26.7 °C DB / 19.4 °C WB INDOOR AMBIENT - kW * (OUTDOOR AMBIENT) 29.4 °C TOTAL SENSIBLE 6.4 8.2 11.2 12.2 35.0 °C TOTAL 6.9 10.7 14.1 16.7 SENSIBLE 6.3 7.9 11 12 40.6 °C TOTAL 6.5 9.9 13.4 15.9 SENSIBLE 6.2 7.5 10.7 11.6 46.1 °C TOTAL 6.2 8.7 12.7 14.9 SENSIBLE 6.2 7.1 10.5 11.3 48.9 °C ** 7.2 11.3 14.7 17.6 TOTAL 6 8 12.4 14.4 SENSIBLE 6 6.9 10.3 11.1 TOTAL 6.7 10.6 13.7 16.3 SENSIBLE 6.3 8.1 11.1 12.2 TOTAL 6.4 10.1 13.1 15.6 SENSIBLE 6.1 7.8 10.8 11.8 TOTAL 5.9 9.5 12.5 14.7 SENSIBLE 5.9 7.4 10.6 11.5 TOTAL 5.8 8.1 11.8 13.9 SENSIBLE 5.8 7 10.3 11.2 TOTAL 5.7 7.5 11.5 13.4 SENSIBLE 5.7 6.8 10.2 11 NET CAPACITY DATA BASED ON 23.9 °C DB / 17.0 °C WB INDOOR AMBIENT - kW * (OUTDOOR AMBIENT) 29.4 °C 35.0 °C 40.6 °C 46.1 °C 48.9 °C ** ELECTRIC REHEAT - kW (Optional 1 stage) 4 UNIT CHARGE - kg (R22) FILTER SIZE - mm - (QTY) DRAIN CONNECTION - mm ID HOSE 6 2.3 3.2 425 X 730 - (1) 400 X 502 - (2) 19 19 19 19 WEIGHT - w/o economiser - kg 160 163 200 209 WEIGHT - w/ economiser - kg 164 167 206 215 ELECTRICAL REQUIREMENTS- Full Load Amps Nominal Supply - Volts/Phase/Frequency Compressor Evaporator motor Electric reheat Condenser motor 240/1/50 11.4 415/3/50 7.5 8.2 10.8 2.5 2.5 4 4 16.7 8.3 8.3 8.3 0.9 0.9 2.5 2.5 41 Our End to End Solutions 42 End to End System Solutions With Emerson Network Power Power Is Just Part of The Reliability Story Emerson Network Power Also Offers A Full Range Of Heat Removal Solutions In addition to proper power, sensitive electronic computer and communications systems also require the correct environment in order to function reliably. Because this equipment produces heat, it is absolutely necessary to control and maintain the temperature and humidity levels where it is located in order to assure continuous operation. The Widest Range Of Products Gives You An Infinite Range Of Solutions As network equipment gets smaller and packed tighter, it creates unprecedented heat densities that can result in thermal shutdown or total component failure. Precision air conditioning, specialized enclosures and rugged remote protection can assure network uptime against this threat. From high-capacity units to compact above-ceiling systems there is a Liebert system designed to cool and protect your critical computing systems. We make the industry’s widest range of precision environmental control, including air conditioners, fluid chillers and heat rejection systems in capacities from one to more than 65 tons. These systems are available with a choice of cooling methods, including chilled water, air cooled and glycol cooled models, as well as ultra energy efficient GLYCOOL™ and Dual-Cool configurations. We also offer specialized systems, including exterior mounted air-conditioning for telecommunications enclosures, supplemental cooling for high-density electronic applications. 43 Emerson Network Power Global Services FACTORY TRAINED You can be sure that the only people who deal with your Critical Air Equipment will be 100% Factory Trained Emerson Service Experts ORIGINAL PARTS You can be sure that the parts you will receive from our 100% Emerson Service Experts are 100% Original Parts. With our multi-tiered parts availability program, you are ensured that parts will be made available to you when and where you need them. VERSION CONTROL You are assured of 100% Version Control so that your critical business systems won’t have to experience downtime due to incompatibility. SUPPORT NETWORK We not only help you develop you Environmental Control System, but our 100% Emerson Service Experts also offer a Full Support Network so that your critical systems have a 100% Safety Net every step of the way. QUALITY RESPONSE We know it is important to get to your critical systems on time. With our 100% Emerson Service Experts you don’t just get prompt service; you also get 100% Quality Response. This means no useless tinkering, no wasted time-- just Quality Service, straight away. 100% Emerson Service Experts. Would you settle for anything less? 44 Our Portfolio Shapes Our Solutions Our Capability Literally Extends From “Grid to Chip”, Offering The Broadest Range of Solutions To The Market. Emerson Network Power offers: • DC Power Systems (Small, Medium, and Large Systems) • Uninterruptible Power Systems (from 500VA to 1000 kVA) • Precision Air Conditioning for Computer Rooms • Shelter Air Conditioning for Telecommunications • Specialized Enclosures to protect Critical Network Equipment • Surge Suppression and Filtering • Site Monitoring Equipment • All Operating System associated Software • Emerson Network Power Global Services (24X7X365 support for all our customers) • Automatic Transfer Switches Medium and Low Voltage • Static Switches 45 Emerson Network Power 1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 T: 614-8880246 F: 614-8416022 T: 800-8779222 ( US and Canada Only) Emerson Network Power Asia Pacific Headquarters 7/F, Dah Sing Financial Centre, 108 Gloucester Road, Wanchai, Hong Kong T: 852-25722201 F: 852-28310114 Country Offices Emerson Network Power (Australia) Pty Ltd Block P, Regents Park Estate, 391 Park Road, Regents Park, Sydney, NSW 2143, Australia T: 61-1300367686 F: 61-2-97438737 Emerson Network Power (China) Ltd No.1 Kefa Road, Science & Industry Park, Nanshan District, Shenzhen 518057, China T: 86-755-86010808 F: 86-755-86010909 Emerson Network Power (Hong Kong) Ltd 7/F, Dah Sing Financial Centre, 108 Gloucester Road, Wanchai, Hong Kong T: 852-25722201 F: 852-28310114 Emerson Network Power (India) Private Ltd Plot No. C-20, Road No. 19, Wagle Industrial Estate, Thane (West),Maharashtra 400604, India T: 91-22-25807000 / 2388 F: 91-22-25828358 Emerson Network Power (Indonesia),c/o PT Emerson Indonesia c/o PT Emerson IndonesiaWisma Pondok Indah 1st Floor, Jl. Sultan Iskandar Muda V TA, Jakarta 12310, Indonesia T: 62-21-7507800 F: 62-21-7507899 Emerson Network Power Division / Emerson Japan Ltd New Pier Takeshiba, South Tower 7F, 1-16-1 Kaigan, Minato-ku, Tokyo 105-0022, Japan T: 81-3-54038594 F: 81-3-54032924 Emerson Network Power (Korea) 8th Fl. HongIk University KangNamArt Center, 51-12 Banpo-Dong, Seocho-Gu, Seoul 137-044, Korea T: 82-2-34831500 F: 82-2-5927883 Emerson Network Power (Malaysia) Sdn Bhd Wisma Glomac 3, Block C, 6th Floor, Jalan SS 7/19, Kelana Jaya, 47301 Petaling Jaya, Selangor Darul Ehsan, Malaysia T: 603-7884 5000 F: 603-7884 5188 Emerson Network Power (New Zealand) Unit 2, 75 Blenheim Road, Christchurch New Zealand T: 64-3-3430235 F: 64-3-3430250 Emerson Network Power (Philippines), Inc. 3/F, King’s Court 1 Building, 2129 Chino Roces Avenue , Makati City 1200, Philippines T: 63-2-8934177 / 178 F: 63-2-8112027 Emerson Network Power (Singapore) Pte Ltd 896 Dunearn Road #03-08, Sime Darby Centre, Singapore 589472, R.O.S. T: 65-64672211 F: 65-64670130 Emerson Network Power (Taiwan) Ltd 11F, 141 Jen Ai Road, Section 3, Taipei 106, Taiwan, R.O.C. T: 886-2-87713655 F: 886-2-87717297 Emerson Network Power (Thailand) Co Ltd 123 Suntowers Bldg.-B, 22nd Fl, Vibhavadi-Rangsit Road, Ladyao, Chatuchak, Bangkok 10900, Thailand T: 66-2-6178260 F: 66-2-6178277 / 278 Countries covered by our Asia Network include: Bangladesh, Sri Lanka, Nepal, Pakistan, Vietnam, Laos,Seychelles, Cambodia, Brunei, Papua New Guinea, Fiji Mail marketing@emersonnetwork-ap.com for contact details. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Power Inbound Power Integrated Cabinet Solutions emersonnetworkpower.com Outside Power Precision Cooling Site Monitoring and Services Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 2005 Emerson Electric Co. APO5TEL01PAR1