Liebert LM Series Surge Protective Device Continuous Protection For Your Business

advertisement
Surge Protection
For Business-Critical Continuity™
Liebert ® LM Series Surge Protective Device
Continuous Protection For Your Business
The Liebert LM Series:
The Most Advanced, Cost-Effective Product Line In The Industry
Standard Liebert LM Series (SPD)
The Liebert LM is a surge protective
device (SPD) that offers continuous
protection from damaging transients
and electrical line noise. The Liebert LM
utilizes patented circuitry to monitor the
status of all protection modes, including
neutral to ground. Should protection be
unavailable in any mode, the green LED
will be extinguished, and the red LED will
be illuminated. In addition, high isolation
form C dry contacts provide for remote
monitoring of suppression system failure,
under voltage, and phase and power
loss. LM patented suppression integrity
monitoring indicates failure for both shorted
or opened suppression components.
Standard Features
Unit Status Indicators
The unit has an integral status circuit
that monitors the operational status
of all modes of protection, including
Line to Neutral, Line to Ground, and
Neutral to Ground. In the unlikely
event that protection is reduced,
the green LED will go out and the red
LED will be lit. LED indication shall
be provided internal and external to
the product.
Enclosure
The unit is housed in a heavy
duty, steel, NEMA 12 dust-tight,
drip-tight enclosure.
Audible
Alarm
Liebert
Corporation
The system
is equipped
1050 Dearborn
Drive with an
P.O.alarm
Box 29186
audible
activated when
Columbus, Ohio 43229
summary
alarm contacts are
800 877 9222 Phone (U.S. &
activated.
An ON/OFF button is
Canada Only)
provided
to
silence
the
alarm,U.S.)
and
614 888 0246
Phone
(Outside
an alarm
push-to-test
button to
614 841
6022 FAX
test the alarm function. A visible
Via Leonardo Da Vinci 8
LED confirms whether alarm is on
Zona Industriale Tognana
or disabled.
Both
buttons
35028 Piove
Di Sacco
(PD) and the
audible
Italyalarm are located on the
39 049
9719
111 Phone
panel’s
front
cover.
39 049 5841 257 FAX
Agency
Listing
Emerson Network Power Asia Pacific
The specified
unit
is ANSI/UL
7/F., Dah Sing
Financial
Centre 1449
Gloucester
Rd, Wanchai
Third108
Edition
(2009),
UL 1283 (Type
Hong Kong
2 locations),
cUL.
At A Glance
Modular design allows for flexibility.
852 25722201 Phone
Undervoltage Detection
Surge suppression range up to
852 28029250 FAX
System monitoring will indicate an
Form C Dry Contacts
500 kA per phase.
undervoltage at 70% of nominal.
Two sets
of electronically isolated
liebert.com
Industry’s highest surge current
form C dry contacts are provided,
repeatability.
Support
Phase and Power Loss Monitoring
(two Technical
normally open,
two normally
Internal/external monitoring, including
800 288 6169 Toll-Free
System monitoring will indicate a loss
closed)
for remote monitoring.
neutral to ground.
607 724 2484 Phone
of any phase or loss of power.
607 722 8713 Fax
UL rated 200k AIC with component level
Warranty
fusing for safe operation.
Noise Attentuation
A full five-year parts warranty.
All modes of protection standard, any
The filter provides insertion loss up to
combination optional.
63 dB from 100 kHz to 100 MHz per 50
Sine wave tracking, EMI/RFI filtering
Ohm Insertion Loss Methodology from
ANSI/UL 1449 Third Edition Listed
MIL Std. 220A.
for Type 1 locations.
Integral Disconnect
ANSI/IEEE C62.11, C62.41, C62.45
Overcurrent Protection
A 200k AIC integral disconnect switch
categories A, B, and C3 tested.
All components are individually fused
located within the system enclosure
Tested to NEMA LS1.
and unit is UL rated for 200k AIC for
with an external manual operator.
NEMA 12 enclosure with 3R, 4,
safe operation.
and 4X options available.
Transient
Counter
Emerson Network Power.
EmersonNetworkPower.com
5-year warranty.
The
system
can be equipped with
Life Cycle™.Testing
global
in enabling Business-Critical Continuity
2 setsThe
of Form
C leader
dry contacts.
a
transient
counter
which totals
The system is life cycle
tested
AC Power
Embedded Computing
Outside
Plantto
Racks & Integrated Cabinets
Audible alarm.
transient
surges
that
deviate from
survive multiple 10kA, 20KV, IEEE
Embedded Power
Power Switching & Controlsthe sine Services
Choice ofConnectivity
options:
wave
envelop
by more than
C62.41 Category C3 transients with
Disconnect.
DC Power
Monitoring
Precision Cooling
Surge
Protection
125
volts.
The
counter
is located on
less than 5% degradation of clamping
Transient counter.
the
unit’s
front
cover
and
features
voltage. The minimum numbers of
Enclosure type.
an
8
digit
LCD,
lithium
batteries
(with
surges the unit shall be able to protect
10-year
life),
and
reset
switches.
against are 8,000 per phase.
Optional Features
2
Specifications
Liebert LM Series
Life Cycle Surge Testing 10kA, 20kV, IEEE, Cat. C3
Per ModeLiebert
PerCorporation
Phase
Unit
Maximum Continuous
Operating Voltage (MCOV)
120V ±25%, all others ±15%
060-080
8,000 1050 Dearborn
16,000Drive
Fault Current Rating (AIC)
200kAIC
100-150
16,000
Location Type
Type 1
Nomimnal Discharge Current (In)
20kA
50 ohm EMI/RFI Attenuation
63dB max from 10kHz to 100MHz
Operating Frequency Range
47 - 63 Hz
Response Time
< 0.5 nanoseconds
Operating Humidity
0% to 95%
Status Indication
LEDs, Dry Contacts, Audible Alarm
Certifications
ANSI/UL 1449 Third Edition, UL 1283 (Type
2 locations), cUL Listed
Enclosure
NEMA 12
Warranty
5 Years Parts
P.O. Box 29186
32,000
Columbus, Ohio 43229
200-250
24,000 800 877 48,000
9222 Phone (U.S. &
Canada Only)
614 888 0246 Phone (Outside U.S.)
ANSI/UL 1449 Third Edition - Voltage
Protection Ratings (VPRs)
614 841 6022 FAX
System Voltage
L-N
L-G
L-L
N-G
Via Leonardo Da Vinci 8
120/208
800
900
1200
700
Zona Industriale Tognana
120/240
800
900
1200
35028 Piove Di Sacco (PD) 700
Italy
346/600
1500
1500
2500
1200
39 049 9719 111 Phone
277/480
1200
1200
2000
1000
39 049 5841 257 FAX
480
X
1800
3000
X
600
X
Emerson
Power AsiaXPacific
2000 Network
4000
7/F., Dah Sing Financial Centre
108 Gloucester Rd, Wanchai
Hong Kong
852 25722201 Phone
852 28029250 FAX
How To Specify The Appropriate Model:
All Liebert LM Series model numbers begin with an LM prefix. Use Chart A to build your Leibert LM Series startingliebert.com
with the Surge Rating
column. Moving left to right, choose the correct configurations from each column for your application. Your completed model number
Support
should look similar to the example below or LM250120YARCE. Refer to Chart B for Liebert LM Series dimensionalTechnical
data.
800 288 6169 Toll-Free
607 724 2484 Phone
C 607 722 8713 Fax
E
Chart A – Example
LM
250
1 2 0
Y
A
R
Model#
Indicators
Surge Rating
L - G Voltage
Configuration
Modes of
Protection
Connection
Options
Low Cost
L
M 60kA/mode 060
120-120V
Single Phase L-N, 2W+gnd
N ALL
80kA/mode 080
208-208V
Single Phase L-L, 2W+gnd
L
100kA/mode 100
220-220V
Split Phase, 3W+gnd
S
Modular
125kA/mode 125
230-230V
Three Phase Wye 4W+gnd
Y
150kA/mode 150
240-240V
Three Phase Delta 3W+gnd
D
200kA/mode 200
277-277V
Three Phase Delta Hi-leg 3W+gnd H
225kA/mode 225
480-480V
250kA/mode 250
600-600V
Monitoring Options
A WireLug N Standard Monitoring
System, LEDs,
Disconnect R Audible Alarm,
S
Dual Form C
Contacts
LEDs, Audible
Alarm, Surge
C
Counter, Dual
Form C Contacts
Emerson
Network
Power.
Chart
B – Liebert
LM Series
Dimensional Data
Dimensions (inches) ™ Approx. Weight
The global leader
in enabling
Business-Critical Continuity .
Unit
Options
A
B
C
D
E
F
AC Power
LM060
LM080Connectivity
All
LM100
LM125DC Power
LM150
LM200
LM225
LM250
All
Embedded Computing
16
20
Outside Plant
Power
14 Embedded
8
16.75
12.0 0.31
Monitoring
35Power Switching & Controls
16
45
9
21.25
10
0.31
Precision Cooling
Enclosure
NEMA 12 (Standard)
E
NEMA 3R
R
NEMA 4
T
NEMA 4X
X
EmersonNetworkPower.com
Racks & Integrated Cabinets
Services
Surge Protection
3
Ensuring The High Availability Of
Mission-Critical Data And Applications.
Emerson Network Power, a business of Emerson (NYSE:EMR), is the global leader in enabling
Business-Critical Continuity™ from grid to chip for telecommunication networks, data
centers, health care and industrial facilities. Emerson Network Power provides innovative
solutions and expertise in areas including AC and DC power and precision cooling systems,
embedded computing and power, integrated racks and enclosures, power switching and
controls, infrastructure management, and connectivity. All solutions are supported globally
by local Emerson Network Power service technicians. Liebert AC power, precision cooling and
monitoring products and services from Emerson Network Power deliver Efficiency Without
Compromise™ by helping customers optimize their data center infrastructure to reduce costs
and deliver high availability.
Emerson Network Power
Liebert Corporation
World Headquarters
1050 Dearborn Drive
P.O. Box 29186
Columbus, Ohio 43229
United States Of America
800 877 9222 Phone (U.S. & Canada Only)
614 888 0246 Phone (Outside U.S.)
614 841 6022 FAX
Emerson Network Power
European Headquarters
Via Leonardo Da Vinci 8
Zona Industriale Tognana
35028 Piove Di Sacco (PD)
Italy
39 049 9719 111 Phone
39 049 5841 257 FAX
Emerson Network Power Asia Pacific
29/F, The Orient Square Building
F. Ortigas Jr. Road, Ortigas Center
Pasig City 1605
Philippines
+63 2 687 6615
+63 2 730 9572 FAX
liebert.com
Technical Support
800 288 6169 Toll-Free
607 721 8840 Phone
607 722 8713 Fax
While every precaution has been taken to ensure accuracy and
completeness in this literature, Liebert Corporation assumes no
responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions.
© 2010 Liebert Corporation. All rights reserved throughout
the world. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks
of their respective owners.
® Liebert is a registered trademark of the Liebert Corporation.
SL-22055 (R03/10)
Emerson Network Power.
The global leader in enabling Business-Critical Continuity™.
Printed in USA
EmersonNetworkPower.com
AC Power
Embedded Computing
Outside Plant
Racks & Integrated Cabinets
Connectivity
Embedded Power
Power Switching & Controls
Services
DC Power
Infrastructure Management & Monitoring
Precision Cooling
Surge Protection
Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co.
©2010 Emerson Electric Co.
Download