Lenntech Fact Sheet info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Sugar Processing Sugar Concentration Duracon* RO-5 8040C The Duracon* family of proprietary thin film reverse osmosis membrane elements are characterized by high flux and excellent sodium chloride rejection. The A-Series membrane has an average rejection of 99.2% on 2000 ppm NaCl at 25°C and 225 psig. The Duracon RO-5 8040C Elements provide ultrahigh rejection of dissolved solids and low molecular weight organic constituents at operating pressures up to 1200 psi (8,274 kPa). This element is designed for processing streams previously treated by ultrafiltration and can be periodically hot-water sanitized. They are typically used for concentrating sugar in food-related processes requiring stringent sanitary procedures. Applications include sugar concentration and waste water applications requiring reduction of BOD. Figure 1: Element Dimensions and Weight The Duracon RO-5 8040C Elements feature a Durasan* patented outerwrap, a selection of feed spacers and polysulfone parts. Table 4: Operating and Design Parameters Table 3: Dimensions Dimensions, inches (cm) Model Duracon RO-5 8040C-30D P1 Duracon RO-5 8040C-50D Duracon RO-5 8040C-50P Duracon RO-5 8040C-30D P1 B C 40 (101.6) 40 (101.6) 40 (101.6) 1.125 (2.857) 1.125 (2.857) 1.125 (2.857) 7.91 (20.1) 1 7.91 (20.1) 1 7.91 (20.1) 1 Weight lbs (kg) 32 (14.53) 32 (14.53) 32 (14.53) 1 The element diameter (dimension C) is designed for optimum performance in GE pressure vessels. Other pressure vessel dimension and tolerance may result in excessive bypass and loss of capacity. Table 1: Element Specification Model A Dry Boxed Membrane A-Series, thin-film membrane (TFM*) Typical Operating Pressure Typical Operating Process Flux Clean Water Flux (CWF)2 200-800 psig (1,379-5,516 kPa) 7-18 GFD (11.9-30.6 LMH) 14 GFD (24 LMH) @ 225 psig Spacer Mil (mm) Active Area ft2 (m2) Part Number Maximum Pressure 1200 psig (8,274 kPa) Maximum Temperature 122°F (50°C) 30 (0.76) 341 (31.7) 1226495 Sanitization Temperature3 194°F (90°C) Recommended pH Operating Range 3.0-10.0, Cleaning Range 2.0-11.5 1000 ppm-hours, dechlorination recommended Duracon RO-5 8040C-50D 50 (0.76) 243 (22.6) 1231100 Duracon RO-5 8040C-50P 50 (0.76) 256 (23.8) 1223048 Chlorine Tolerance 2 Clean water flux (CWF) is the rate of water permeability through the membrane after cleaning (CIP) at reproducible temperature and pressure. It is important to monitor CWF after each cleaning cycle to determine if the system is being cleaned effectively. CWF can vary ± 25%. Table 2: Pressure Drops Maximum Pressure Drop ∆P - psig (kPa) Elements per Pressure Vessel 1 2 3 4 5 15 (103) 30 (207) 45 (310) 60 (414) 60 (414) 3 Hot Water Sanitization Recommendations: Elements should be cleaned with approved CIP procedure and flushed with fouling-free clean water before sanitization process. Feed pressure during sanitization should not exceed 40 psi and the crossflow should not cause higher than 2 psi pressure drop per element. Heating rate to sanitizing temperature should not be higher than 5°C/min and cool down rate should be the same. ©2006, General Electric Company. All rights reserved. *Tr a dema r k of Genera l Elec tr ic Compa ny ; ma y be r egis ter ed in one or more c ountr ies . FS1210EN 0607