Information Details version V1.4 Date of filing 2010-11-30

EP67 Exit Button User Manual

1 Summarize

EP67 Exit Button is one relevant device of our Access Control products, it is made by high strength steel stainless, durable to use. Some contacted parts inside are made by metal, touch sensitive. It make the status convert itself: usual open or usual closed, to get the function open and close in the connection. It is widely used in Access Control Device management, fire protection and security system In-Out management system.

1.1 Products instructions

1.1.1 Appearance and port

B

L

Dimension: 88MM*88MM*20MM Error range: ±5%

Dentification L B D

Dimension(mm) 88 88 20

1.1.2 Terminal port

Terminal defines

NC

Usual close port

COM

Common port

NO

Usual open port

1.2 Parameters

Color: silver white; weight: 0.15Kg ±5 % ;

Standard structure: steel stainless board, metal button;

Electric property: maximum current 3A @36VDC;

Contact output: NO\NC\COM contacts;

Accessories optional: ABK - 801B - M;

Suitable style: hollow door;

Surface processing: Stainless steel wiredrawing processing;

Working method: press button operation;

Service time: more than 100 thousand times;

Durable test: passed 500 thousand times aging test;

Service place: indoor;

Working status: usual open: means user connect the wirelss at the ususal open port (N.O) and common port (COM), the door holder will be always open, press the door holder, the circuit will be conduction state; closed status: means user connect the wireless at the usual closed port (N.C) and common port (COM), the door holder is always closed, press the door holder, the circuit will be off-state.

2 Installation

2.1 Environment requirement

1. Service place: indoor;

2 . No conductive dust, no corrode metal and damage insulation air;

3 . Avoid using in the water and fog area;

4 . working environment: 0~50 ℃ , 20~90 % (no condensation and frozen);

5. saving environment: -20~60 ℃ , 20~90 % (no condensation and frozen);

2.2 Inspection when open box

Open the Exit Button packing, check the appearance, if find it damaged, contact with the delivery.

Refer to the delivering list, check the Exit Button and accessories compelete and right.

2.3 Mechanical installation

Install the accessories and the installing method as followed picture.

Take out the wireless from 86 cassete, following the required method

(usualopen or usual close) to connect withe the contacts of the button.

And then use the attached screws to fasten it on 86 cassete.

Attention:

When install the button, contacts method (usual open or usual closed) must be correct;

When connect the wirelss must fasten it tightly, if not the button may be invalid status after using a little long time.

3 Maintainance

1 . if need to clean, please cut the power and use soft cloth to clean;

2 . not professional people take apart itself is not available, in case to damage the parts.

Appendix toxic and harmful substance or element logo table

Toxic and harmful substance or element

Name lead

Pb mercury

Hg cadmium

Cd

Cr VI

Cr

6+

PBB

PBB

PBDE

PBDE board

× ○ ○ ○ ○ ○

: means the content of the toxic and harmful substance in the parts is under SJ/T-11363

2006 ruled limited content;

×

: means the content of the toxic and harmful substance in the parts is more than SJ/T11363

2006 ruled limited content.

EMERSON Network Power Co., Ltd. has commited to designing and producing environment-friendly products. We try to discrease and eliminate the toxic and harmful substance of the products through our persistent researching. The below components or application is limited to the present technology level that can not find the reliable repalcement or no mature solution: the board content Pb.

Instructions of environment protection service time: The environment protection service time (marked on the products) means under the normal using condition and followed the security reminds of the product , from the Date of Manufacture, some of the toxic and harmful substances or elements that the products contents can not make bad effect or influences to the environment, people and property.

Applicable scope: EP67 Exit Button

EMERSON Network Power Co., Ltd.

Address:No. 1 of Kefa Road, Science and Technology Park, Nanshan District,

Shenzhen

Post code: 518057 Website: www.emersonnetworkpower.com.cn

Service Line: 4008876510 E-mail: service@emersonnetwork.com.cn