Liebert® RDU-M Dynamic Environment Monitoring for Secure Data Center Infrastructure Manage critical equipment activity involving data center power and thermal management at multiple sites and site monitoring around the clock. Emerson Network Power provides 24x7 data center infrastructure management and network monitoring software, hardware, systems and services to provide continuous oversight and security of data centers, computer rooms and network closets, as well as applications for different market verticals. Mission critical facilities are vulnerable to threats such as excessive heat, power problems, unwanted access, humidity and air impurities to name a few. Data center management doesn’t stop in investing to air and power infrastructure equipments, monitoring plays an integral part of the entire infrastructure. Critical infrastructure monitoring is the key to assuring high availability and maximizing the investments made in these critical facilities. Infrastructure Challenges Challenge: Infrastructure Management Need: A solution for centralized management of the entire infrastructure Challenge: Heat Density Need: Environmental Monitoring at Room and Rack Level Challenge: Power Density Need: Efficient power management tools Challenge: Accessibility Need: Access type monitoring for rack or data center Challenge: Availability Need: Thresholds, event generation and notification capabilities 3 Liebert® RDU-M The Liebert® RDU-M provides round the clock visibility and holistic monitoring approach to your data center. This infrastructure management platform delivers real time monitoring and dynamic management of the entire IT facility from room, rack and equipment level. The Liebert® RDU-M monitoring software is already installed in a server like hardware appliance that can easily fit in racks and cabinets. It is also capable of managing multiple monitoring systems, all at the same time, as it easily integrates environmental and security systems placed in the data center. The Liebert® RDU-M best applies from small, medium-sized and cloud-ready data centers and applications. System Integrated Simple installation and automatic system integration of monitoring equipments present in the data center using standard port connections for power, image and video, environment and access & control applications Real-time Monitoring Provides real-time access and information to environmental, power, cooling and security aspects of the data center and reported via email and SMS Remote Management Capable of intelligent management of equipments and applications from a remote location Multi-level monitoring for the entire critical infrastructure Provided room level, rack level and equipment level monitoring Facility Safety Multiple pre-alarm threshold, modes and levels providing preventive alerts to administrators Full video surveillance of the facility that includes recording, replay and image capture of the facility Intelligent room and door access functionality issued to authorized IT personnel Security & Peace of mind Linux operating system; reliable and less frequently affected by virus. Multilevel system management that provides different access levels to different administrators. Capable of backup and querying of historical data of devices, system operations, alarm notifications sent to administrators Simplified use and maintenance User-friendly and customizable graphic interface for a holistic view of the data center Provides report and analysis of data center and equipment operation including PUE statistics IP network connectivity, standard network cable connection and web remote access capability System cloning and critical data backup function for simple and convenient maintenance 4 Liebert® RDU-M Models Features: Offers a user-friendly GUI to set up and manage data center infrastructure appliances Real-time monitoring on environmental, power, cooling, and security in data center Video surveillance supports video recording/back up/replaying/picture capturing/voice transmission/ timed recording and recording action triggered by alarm Room access control management Relay actions triggered by alarm or events Alarm notification by Email, SMS Report and analysis on data center / device operation; PUE statistics RDU-MP RDU-MI RDU-MII Centralized management platform for RDU-A and RDU-SIC Centralized management platform for RDU-A and RDU-SIC Centralized management platform for RDU-A and RDU-SIC Can manage RDU-A and/or RDU-SIC up to 32 connections Can manage Emerson Door Access systems up to 32 sets Can manage RDU-A and/ or RDU-SIC up to 128 connections. Door = 64 IP Camera = 64 Can manage RDU-A and/ or RDU-SIC up to 256 connections. Door = 256 IP Camera = 256 5 The Liebert RDU-M provides a holistic view of the infrastructure while monitoring the data center environment and the equipment status in real-time. 6 3D Capabilities 3D Graphical Image Zoom In Collapse Space Usage Critical Alarm Rack Zoom 3D Thermal Mapping 7 Data Center Video Surveillance & Monitoring System Features: High performance and high speed video protocol processor Optimized H.264 video compression algorithm for smooth transmission of the HD image at low bandwidth Built-in Web Server functionality, facilitates the real time monitoring and management setting of the front end of the equipment through standard IE explorer Supports remote system upgrade Connectivity: DNS, LAN and Internet (ADSL, Cable Modem) Supported network protocols: HTTP, TCP/ IP, UDP, STMP, DDNS, DNS, SNTP, DHCP, FTP Supports two-way voice intercom and voice broadcasting Self-adaptive network technology and automatic adjustment of video frame rate according to network bandwidth Alarm functions for video loss and motion detection (configurable area and sensitivity) Built-in high-speed dome decoder protocol Video recording / Still image capture Automatic recovery function and connection during network interruption or disturbances Supports up to 32GB of SD 2.0 protocol Installation: Flat or wall mounted Hemisphere & Bullet Camera High Sensitivity LCD Automatic white balance tracking and gain control Digital signal processing and CCD aperture Video Surveillance IP Camera Network Video Recorder (NVR) (NVR LAN/WAN - TCP/IP RDU-M IP Camera 8 Network twork Video Recorder (NVR) (NV Battery Monitoring System Liebert RDU-M also monitors the state of batteries in real time. It provides battery discharge data, playback and understand the discharge trend. RDU-A G2 Modbus 485 Battery Monitoring System LAN/WAN - TCP/IP RDU-M Battery Monitoring System 1. The battery group voltage, resistance, and maximum, minimum, average value of temperature, etc. 2. Monitoring of battery state, the alarm information and charge and discharge state. 3. Monitoring of battery discharge data, discharge playback, to understand the discharge trend. 9 Environment Monitoring System Temperature/Humidity Sensors Monitor room temperature and humidity Alarm Beacon Flashing LED beacon provides visual exception event notification Smoke Sensors Monitor fire / smoke in the room or cabinet Water Stripe Sensor Detects water perimeter leakage IR Detector A thermographic camera or infrared camera is a device that forms an image using infrared radiation Alarm Management Email Phone Alarm (No Voice) SMS m Modem LAN/WAN - TCP/IP Buzzer Alarm via Contact Closure 10 Windows 7 server Buzzer Multimedia SMS Voice Liebert RDU-M Hardware Technical Specifications ® Requirements on Client Operating Environment IE 6.0 or above version WEB Browser Hard disk: 1G and above, memory, 1G and above, network card, 10MB and above OptimizeIT server bandwidth: 10MB and above Client bandwidth requirement: 10MB and above Hardware Configuration Network Bandwidth Power Supply AC power supply equipment (each power supply equipment) RDU-MP 350W, Auto Ranging(100 – 240 VAC, 50/60 Hz). RDU-MI 350W, Auto Ranging(100 – 240 VAC, 50/60 Hz) RDU-MII Redundant power infeed, 350W x 2, Auto Ranging (100 – 240 VAC, 50/60 Hz). Voltage 100-240VAC, 50/60Hz Maximum Surge Current Under the typical circuit condition and within the operating range of the overall system environment, the surge current of every power equipment is likely to reach 25A within 10millisecond or even a shorter time. Category RDU-MP RDU-MI RDU-MII Weight 8Kg 8Kg 15Kg Dimension 42.6 x 431 x 393.7 (mm) 42.6 x 431 x 393.7 (mm) 42.9 x 434.0 x 612.6 (mm) 1.67” x 17.1” x 15.5” 1.67” x 17.1” x 15.5” 1.69” x 17.10” x 24.12” (with mounting bracket and bezel) RDU Integration 2-layers 2-layers RDU RDU-A, RDU-SIC RDU-A, RDU-SIC Quantity allowed <=32 (IP Address) <=128 (IP Address) 3-layers RDU-MII/MI/MP, RDU-A, RDU-SIC <=256 (IP Address) and <=16 RDU-M Video Surveillance Camera Type Not Available IP Camera (Dome/Box) IP Camera (Dome/Box) Quantity allowed None <=64 (IP Address) <=256 (IP Address) Quantity of door access controller allowed <=32 <=64 <=256 11 Liebert RDU-A G2 ® The Liebert® RDU-A G2 is an infrastructure management solution from Emerson Network Power that allows data center administrators to manage environmental conditions i.e. temperature and humidity, leak, smoke, vibrations and digital inputs and outputs. It is also capable of monitoring infrastructure appliances such as UPS, precision cooling units, generator sets and etc. The Liebert® RDU-A G2 is equipped with a built-in web server, eliminating the need to perform a software installation. The Liebert® RDU-A G2 allows data center managers to perform the following operations through a secure web page: Monitoring of the health and status of the equipment Monitoring of environmental conditions i.e. temperature and humidity, leak and smoke. Improved communication speed in transmitting control or commands to the equipment and parameter setting Data and logs of historical information of alarms and notifications FRONT 3rd Party Communications: SNMP Modbus 485 Dry contacts BACK The Liebert® RDU-A G2 serves as the communication gateway for the equipment and the Liebert® RDU-M solution. It intelligently collects and communicates data and commands, giving IT administrators a comprehensive view of what’s happening at the equipment level of the facility. Mechanical Specifications External model IRM-HOST2 IRM-4COM IRM-8DIAI IRM-8DOAO Measurement Height Width Depth Valve 43mm 440mm 311mm Weight <8kg Height 20mm Error <±0.5 mm <±1 mm <±1 mm <±0.5 mm Width 158mm <±1 mm Depth 199mm <±1 mm Weight <1kg Environment Conditions Item Application location Working temperature Relative humidity Working environment Air pressure Storage temperature Cooling Power distribution network Protection level 12 Requirement Usually in data center or computer room, with air conditioner -10ºC ~ +60ºC 5%RH ~ 95%RH, no condensing Dust: compliant with the indoor requirements of GR-63. No corrosive gas, flammable gas, oily mist, steam, water drops or salt 70kpa ~ 106kpa -40ºC ~ +70ºC Natural cooling TT/TN IP20 Access Control System The access control system of the Liebert RDU-M primarily provides security and prevention of unauthorized access or entry to the data center facility. The hardware components of this access control system is based on leading international facility security designs that is also equipped with high adaptability to monitoring systems, clock technology, surge and lightning protection design, anti-interference and anti-static designs. Access Control Box Dimensions: Maximum Connection Distance: Display: Lock Driving Interface: Contact Capacity: Card Reader Port: Operating Temperature: Storage Temperature: Humidity: Fingerprint Reader Dimension: Weight: Working Voltage: Working Current: Car Type: Frequency: Reading distance: Working environment: ESD parameter: (L×W×H): 380mm×200mm×69.5mm 1200m 6-digit red LED, displaying numbers or simple English characters NO/NC contacts DC12V/2A/25Sec, DC24V/2A/25Sec, AC75V/3A/25Sec Wigan Signal Input Effective Low Level (or OC Door Conduction): -0.7V- +0.7V, IOUT MAX =8mA Wigan Signal Input Effective High Level (or OC Door Shut-off): high resistance -+4.0V, IOUT MAX=0mA Wigan 26BIT, 34BIT, Wigan Signal Input Effective High Level (or OC Door Shut-off): high resistance -+4.0V, IOUT MAX=0mA Wigan 26BIT, 34BIT, 36BIT and 44BIT card number automatic identification -10oC~50oC -30oC ~70oC 5% ~ 95%RH (no condensation) 155mm(L) * 52mm(W) * 39mm(D) ±5% 0.2Kg±5% 12VDC±5% 300mA±5% ID or IC card ID card: 125KHZ±5% IC card: 13.56MHZ±5% 50-100mm (without other same products interferences) -10~+55º C degree, -20~+70ºC, 5%~90% 20%~90% air discharge ±8KV 13 Electrical Lockset Rated Operating Voltage: Input Voltage Range: Operating Current: Minimum Supply Current: Rated Power: Rated Pulling Force: Door Open Mode: Operating Environment: Temperature: Humidity: Applicable Door Type: Outside Button Model: Maximum Switch Current: Operating Temperature: Button Material: Panel Material: Mechanical Life: Projecting Button Size: Pane Size: 12V DC 10.8VDC-13.2VDC Single-opened: 0.48A Single-Opened: at 800mA/12V DC input single-opened: ≤6.2W Single-Opened: 270Kg±5Kg 90o 10oC ~ +50oC 20% ~ 90% (no condensation) Applicable to wood door, glass door without bottom frame (with U support) and fireproof door EP67 48VDC, 2A -25oC ~ -105oC Brass with nickel plating Stainless steel 1,000,000 times ¢ 22×2mm 86×86×6mm Access Management RDU-A G2 RS 485 Lock Controller LAN/WAN - TCP/IP RDU-M Lock Exit Button Card Reader Finger print / Card + Password Dual Swing Glass Door 14 Device Management 1. Device status monitoring (PUE, Teamwork) 2. Device Control and monitoring 3. Individual monitoring interface for each device. LAN/WAN - TCP/IP Energy Management LAN/WAN - TCP/IP Server, switch, etc. Light, camera, etc. Metered PDU Power Meter Power Meter UPS, Cooling, etc. PUE Model Power Calculate by the monitoring the power meter. PUE Model Energy Calculate by the direct reading of UPS power. Can also be computed by manual entry results Mobile Based on Java Script, CSS, HTML LAN/WAN - TCP/IP OS Type 1. Windows 15 Applications: Small Computer Rooms How much do you need to manage in small computer rooms / Data Centers? With this solution, top management monitoring platform is easy to achieve with user friendly graphics and configurations. RDU-M LAN/WAN - TCP/IP RDU-A G2 Infrastructure Appliances 16 Applications: Medium Sized Data Centers Expanding your data center? With this solution, scaling to adapt to your current changes is manageable and easy to maintain. LAN/WAN - TCP/IP RDU-A G2 RDU-A G2 RDU-M Infrastructu Appliances Security and Infrastructure 17 Applications: Enterprise and Cloud Ready Data Centers Cloud Ready? Data Centers on cloud need not to be expensive in terms of management. Scalability with security is the key. MAIN NOC Site C LAN/WAN - TCP/IP Site B 18 Site D Make your Data Center as Dynamic as Your Business AC POWER POWER SWITCHING & CONTROLS Power switching and controls for emergency, critical, standby and distributed power Critical power management systems used locally or remotely Load banks up to 15K for generator and UPS testing or exercising Surge Protection Devices (SPD) for commercial and critical power markets Related services include maintenance, commissioning, product upgrades and reliability assessments Industry-tested power protection and back-up power solutions Uninterruptible Power Supplies: Desktop, Rack and Row based, Room and Site-based Power Distribution Units: Room-based with metering & voltage transformation, Rack mountable with metering & management capabilities MODULAR CONTAINERIZED DATA CENTRE Fast and efficient deployment, anytime, anywhere Pre-assembled and factory tested to ensure quality and reliability Fully integrated power and climate systems Custom designs available to meet individual site needs Wide variety of applications: oil & gas, mining, military, telecom, data centres Easy to deploy solution for high density requirements Provides the components of a high availability enterprise data centre into an enclosed aisle of racks Integrated DCIM capabilities for building and IT facilities management and capacity planning Visibility of critical infrastructure life signs in a local office, equipped with power protection solution suitable for remote locations or across a distributed network THERMAL MANAGEMENT Industry’s most efficient and reliable management of heat Achieve industry leading efficiency levels (PUE <1.1) Complete line of energy efficient, and reliable technology solutions Data centre controls and service to optimize efficiency and uptime ENERGY SYSTEMS SERVICES Best-in-class DC Power Solutions adapted by major telecom providers around the globe Modular system architecture minimizes capital investment while allowing future growth Increased intelligence to match utilization to capacity Streamlined technology that reduces failure points and ensures high reliability DATA CENTRE INFRASTRUCTURE MANAGEMENT Complete life-cycle approach from project launch to ongoing maintenance performance optimization Largest service footprint in the industry: 945+ Service Field Engineers, 95+ Service Centres, 75+ Technical Support/Response in Asia Pacific Project Management, Equipment Maintenance and Performance Optimization capabilities Real-time, data centre optimization platform Inventory management and site management and monitoring Change planning Energy Insight, Power Management and Thermal Management Change the way your data centers are managed—your top priority today An imperative to improving performance and controlling costs It has never been more difficult to manage a data center. The demand for services, environmental complexity and criticality of availability is at an alltime high. Add to those factors a constant pressure to control costs, and it is easy to understand why organizations are rethinking how they run the data center. By implementing the right combination of hardware and software solutions to manage the data center infrastructure, you can: Reduce day-to-day costs and time involved in operating and maintaining the data center Enable better management decisions by getting the right information to the right people at the right time Make better use of existing IT and infrastructure resources, optimize data center performance and improve system availability Emerson Network Power is the trusted source for innovative solutions and expertise in power and precision cooling systems, integrated racks and enclosures, power switching and controls, monitoring and connectivity. With our Liebert®, Avocent and Aperture® brands, we’ve been delivering data center infrastructure management benefits for years. 19 Emerson Network Power Asia Australia T: 1800-065345 F: 61-2-97438737 Pakistan T: 92-42-36622526 to 28 F: 92-42-36622530 Indonesia T: 62-21-2513003 F: 62-21-2510622 Philippines T: 63-2-7207400 F: 63-2-6203693 Japan T: 81-3-54038564 F: 81-3-54032919 Singapore T: 65-64672211 F: 65-64670130 Korea T: 82-2-34831500 F: 82-2-5927886 Thailand T: 66-2-6178260 F: 66-2-6178277 to 78 Malaysia T: 603-78845000 F: 603-78845188 Vietnam T: 84-4-37628908 F: 84-4-37628909 New Zealand T: 64-3-3392060 F: 64-3-3392063 www.EmersonNetworkPower.Asia While every precaution has been taken to ensure accuracy and completeness herein, Emerson Network Power assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. Emerson Network Power and Liebert® are trademarks of Emerson Electric Co. or one of its affiliated companies. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. ©2014 Emerson Electric Co. AP14ENT-Liebert®RDUMV2-BR