Yokogawa Explosion-Proof Meters

advertisement
Yokogawa Explosion-Proof Meters
YPP6820 Rate/Total Meter
• 4-20 mA input loop-powered
• 5-digit rate display
• 7-digit totalizer
• 32-point, square root or exponential linearization
• Rate in units per second, minute, hour, or day
• Open collector pulse or alarm output
• Loop or external DC-powered backlight
• HART® protocol transparent
YPP6830 Pulse Input Rate/Total Meter
• Pulse, open collector, NPN, PNP, TTL, switch
contact, sine wave (coil), square wave, optoisolated inputs
• 5-digit top display for Rate or Total
• 7 alphanumeric character lower display for Rate,
Total, Grand Total, Units, and Tag
• 13-digit Totalizer with total overflow feature
• Isolated 4-20 mA output for Rate, Total, or Grand
Total
• 2 isolated open collector pulse outputs, to 5 kHz
• Battery, DC, or output loop-powered models
• Gate function for rate display of slow pulse rates
• K-Factor, scaling, or live input calibration with
32-point linearization
• Automatic Rate, Total, and Grand Total unit
conversions
• 1024 point on-board data logging
• Modbus communication RS-485 options
YPP6870 Process Meter
• 4-20 mA input
• 3½ digit, 1" (25.4 mm) display
• 1 V drop (4 V with backlight)
• Loop-powered backlight option
• HART® protocol transparent
37b
YPP6820
YPP6830
YPP6870
YPP6801
PROCESS METER
YPP6801 Level Meter
• Display level in feet & inches
• 4-20 mA input loop-powered
• Lower display for tag, volume, or %
• 20-segment tank level bargraph
• 32-point linearization
• Live input calibration
• Open collector alarm output
• Loop or external DC-powered backlight
RATE/TOTAL
LEVEL METER
• Die-cast NEMA 4X, IP68 enclosures
• 90º rotatable display with wide viewing angle
• Two ¾" NPT conduit holes
• Flanges for wall or pipe mounting
• Through-glass button programming
• Password protection
• FM, CSA, ATEX, and IECEx approvals
• Easy field setup and wiring
SPECIFICATIONS
Voltage Drop
Power Options
YPP6801
Level Meter
4-20 mA
±0.03% of span ±1d
5-digit
Feet & Inches
0.7" (17.8 mm)
0.4" (10.2 mm)
399' 11"
N/A
N/A
Front Panel,
Through-glass
3.0 V (6.0 V*)
Input Loop
YPP6820
Rate/Total
4-20 mA
±0.03% of span ±1d
5-digit
Decimal
0.7" (17.8 mm)
0.4" (10.2 mm)
99,999
9,999,999
Dual
Front Panel,
Through-glass
3.0 V (6.0 V*)
Input Loop
Backlight
Standard
Standard
Model
Meter Type
Input
Accuracy
Display
Type
Upper Display
Lower Display
Process/Rate
Total
Rate & Total
Programming Method
YPP6830
Rate/Total
Pulse
--5-digit
Decimal
0.7" (17.8 mm)
0.4" (10.2 mm)
99,999
9,999,999
Dual
Front Panel,
Through-glass
N/A
Output Loop,
Battery, 12-36 VDC
Standard
YPP6870
Process
4-20 mA
±0.1% of span ±1d
3½ digits
Decimal
1.0" (25.4 mm)
None
1,999
N/A
N/A
Front Panel
1.0 V (4.0 V*)
Input Loop
Optional
Common Specifications:
Temperature:
-40 to 75°C operating, <90% RH non-condensing
Enclosure:
die cast aluminum NEMA 4X, IP68 explosion-proof
Mounting:
Wall, pipe, conduit
Connections:
Screw terminals accept 12-22 AWG wire
Approvals:
FM , CSA, ATEX, IECEx, CE
Dimensions:
5.25" x 5.65" x 4.86" (134 x 144 x 124mm)
Warranty:
3 years standard
* with backlight
ORDERING INFORMATION
YPP6801-0K1
YPP6820-0K1
YPP6830-AP0-0
YPP6830-APA-0
YPP6830-BM0-0
YPP6830-BMA-0
YPP6830-BTA-0
Feet & Inches Meter with Backlight & Open Collector Output
Analog Input Rate/Totalizer with Backlight
Pulse Input Rate/Totalizer, DC powered
Pulse Input Rate/Totalizer, DC powered with isolated loop output
Pulse Input Rate/Totalizer, Battery powered (or DC with battery backup*)
Pulse Input Rate/Totalizer, Battery powered (or DC with battery backup*) w/ isolated loop output
Pulse Input Rate/Totalizer, Battery powered (or DC with battery backup*) w/ output loop-powered
backlight and isolated loop output
YPP6830-CTB-0
Pulse Input Rate/Totalizer, Output loop powered with loop output
YPP6830-DTB-0
Pulse Input Rate/Totalizer, Output loop with battery backup* (or battery powered) w/ loop output
YPP6870-0L0
Large Display Process Meter
YPP6870-0K0
Large Display Process Meter with Backlight
YPP6830 options (not available on -CTB and -DTB versions):
2-wire RS-485 connection with Modbus protocol: Replace ending -0 in part number with -M.**
Isolated signal 2-wire RS-485 with Modbus protocol: Replace ending -0 in part number with -I. **
* Battery will provide backup power when other power supply is lost.
**RS-485 communication functions only when powered by DC.