London Electronics Large Display Meters Fusion • Analog & Digital Inputs • Large, Bright Digits • Setup Without Menus • Indoor & Outdoor Models • Choice of Mounting Position Easy Reader L ER SPECIFICATIONS Counter Input: Signal Type: Range: Excitation: Loadcell Input: Resistance: Excitation Serial Input: RS232 or RS485 300-115200 baud Display: -1999 to 9999 (4d) -199999 to 999999 (6d) Accuracy: ±0.05% of range Analog Out: >1kΩ 16 bit resolution direct or inverse 250VAC isolation Relays: SPST 2A@250VAC resistive Selectable NO or NC Selectable energize or deenergize Temperature: 0-50°C operating Connectors: detachable screw terminals Power: 50VA max. Case: Black uPVC, 75mm depth 0-10V, ±13V, 4-20mA, ±24mA 1MΩ on V, 33Ω on mA 24V 60mA Type J, K, T, R, S, B 3 or 4 wire PT100 RTD 4 channels Logic level; AC tach; NPN, PNP pulses <24V; 100mV inductive pickup; Contact closure 0-40kHz 24V 60mA 4 or 6 wire >10MΩ 10V 120mA ORDERING INFORMATION Example: Fusion2-F2-4N-P-0-AL2-232-B-AC-1-0 Fusion2 - A – B – C – D – E – F – G – H – A B C D Digit Height F2 F4 F6 F8 F12 F16 Digit Format 4N 4C 6N 6C 8N Function C H L M P S2 S4 T Analog Output 0 ANI ANV ANB E 2" (57mm) 4" (102mm) 6" (150mm) 8" (200mm) 12" (300mm) 16" (400mm) 4 digit numeric 4 digit clock 6 digit numeric 6 digit clock 8 digit numeric Counter Clock/timer Loadcell Millivolt Process RS232 slave RS485 slave Temperature None 4-20mA 0-10V ±10V F G H I 0 AL2 AL4 SPCO DSS Serial Output 0 232 485 Display Color R G Y B W RDLV GDLV YDLV BDLV Supply AC DC Mounting 1 2 3 4 5 6 I -0 Alarm Outputs None 2 alarms 4 alarms 2 SPDT relays 2 solid state relays None RS232 RS485 Red Green Yellow Blue White Red bright Green bright Yellow bright Blue bright 95-265VAC 50/60Hz 11-30VDC Panel, IP65 front Wall, IP65 Top Suspension, IP65 Wall, IP54 Top Suspension, IP54 Rear Suspension IP54 A simple and affordable way to see and share important measurements over large distances: • 2" (57mm) digits for viewing up to 65ft (20m) • 4" (102mm) digits for viewing up to 130ft (40m) Available in 5 input types, these meters can be configured from the front panel. SPECIFICATIONS Process Input (Type P): Accuracy: Display by: Count Input (Type C): Accuracy: Slave Input (Type S): Format: Addressing: Reset: Excitation: Operating Temperature: Power: Dimensions: 4-20mA, 0-10V, 1-5V, scalable ±0.1% range ±1d @25°C 1, 2, 5, 10, 20, 50 NPN, PNP or contact closure ±0.05% range ±1d @25°C RS232, RS422, RS485 or TTY ASCII data from 300-9600 baud 00 to FF Front panel or remote contact closure 24VDC, up to 30mA (except Slave) 0-50°C, <95% RH non-condensing 95-265VAC, 11-30VDC ER2 10.3x5.8x1.8" (260x140x45mm) ER4 16.4x7.7x1.8" (415x195x45mm) IP54 dust tight (IP65 optional) Sealing: ORDERING INFORMATION To Order—Insert Code for Each Letter to Select Catalog Number. Example ER4P-2-O-O ER A B C D E A B – C – D – E Digit Size 2 4 Type P C S H T Mounting 1 2 3 6 Power 0 DC Brightness 0 DLV 2" 4" Process Input Count/rate Input Slave (ASCII) HH:MM Clock TC & PT100 RTD Flush Panel Wall Suspension Top of Cabinet 95 - 265VAC 11-30VDC Normal Ultrabright 38 DIGITAL METERS Process Input: Resistance: Excitation Temperature Input: