Schneider Electric Power Meter SPECIFICATIONS •

advertisement
NEW
Schneider Electric Power Meter
PM1200
• Measures current, voltage, power,
PF, frequency, THD & energy
- active, reactive, apparent
• 4 digit TRMS readout with automatic
scaling (K, M, G units display)
• Accuracy class 1.0
• Color coded analog load bar
• Rapid setup from the front panel
• User selectable default display page
• Direct connection up to 480Vac
• Modbus RS-485 interface
• Password protected keypad lock
Measurements
Current:
Voltage:
Power :
Energy:
Unbalance:
Power Factor:
Demand:
per phase & neutral
average, phase to neutral & phase to phase
active & apparent; total & per phase
active, reactive & apparent
current, voltage
average and per phase
present & max current, present & max active
apparent power
Power Quality:
THD for current & voltage, per phase
Other Parameters: Frequency, phase angle, run time, RPM
ORDERING INFORMATION
PM1200
Power Meter with energy & demand, RS-485 interface
SPECIFICATIONS
Measurement:
True RMS up to 15th harmonic
Sample rate:
20 samples/cycle at 50 Hz
Accuracy (of reading): Current & voltage 1.0%
Active & apparent power 1.0%, reactive 2.0%
Apparent energy 1.0%
Active energy IEC62053-21 class 1
Reactive energy IEC62053-23 class 2
Power Factor 1%; Frequency 0.1%
Data update rate:
1 second
Voltage inputs:
V1, V2, V3, Vn
Measured voltage: 80-480 V L-L without PTs
Up to 999 kV with external PTs
Overload:
1.1 Vin (480V L-L)
Burden:
0.2 VA per phase max.
Impedance:
4MΩ L-L, 2MΩ L-N
Frequency:
45 - 65 Hz
CT primary rating:
1 A to 99.0 kA
CT secondary rating: 1 - 5 A
Current inputs:
A1, A2, A3
Measurement range: 50 mA - 6 A (starting at 5 mA)
Overload:
10 A continuous
Burden:
0.2 VA per phase max.
Input resistance:
< 0.1 ohm
Display:
3 parameter, 4 digit LED with auto-scaling (k, M, G)
Displayed parameters: User selectable default display page
Communications:
2-wire RS-485, Modbus RTU, up to 19200 bps
Power supply:
44-277 VAC, 50/60 Hz; 44-277 VDC, 3 VA
Operating temperature: -10 to +60°C (14-140°F), 5-95% RH non-condensing
Dimensions:
96mm x 96mm bezel, 83mm behind panel
Protection:
IP51 front, IP40 back
Rating:
CATIII, protection class 2, pollution class 2
Newport Graphical Display Panel Meter
SPECIFICATIONS
Display:
Display Formats:
• High resolution, backlit graphical
display
• Universal Input accepts thermocouples, RTD & Process V/I
• Displays input as horizontal bar
graph, line graph or 4 digit readout
• Records 85,000 data points with
time stamping
• Data logging based on time and
date, alarm 1 or 2, or key press
• Displays min/max process values
• Power from 90 to 240 Vac
DPi1701
This versatile meter can be configured to accept T/Cs (J, K, T, E, R, S),
RTDs (2- or 3-wire), voltage (0-10Vdc) or current (0- 20mA). The high
intensity, backlit, graphic display (240 x 64) provides powerful display
features such as horizontal bar graph, line graph and data logging in
real time. Options include two Form C relays, isolated USB or RS232
interface, isolated analog output, isolated 24 Vdc excitation and
license-free IEEE802.15.4 wireless transceiver.
ORDERING INFORMATION
DPi1701/N
DPi1701-USB-R/N
DPi1701-USB-AR/N
DPi1701-USB-ARW/N
33a
NEW
Graphic panel meter & logger with isolated RS-232
Graphic panel meter & logger with 2 relays, isolated USB
& 24V excitation
Graphic panel meter & logger with 2 relays, isolated USB,
24V excitation & analog output
Graphic panel meter & logger with 2 relays, isolated USB,
24V excitation, analog output & wireless receiver
Monochrome, 240 x 64 dots, yellow backlight
Standard digital, large digital, horizontal bar graph, line
graph charting
4 samples per second
Sampling Rate:
Thermocouple Input:
Type J:
-100 to 760°C (-148 to 1400°F)
Type K:
-100 to 1260°C (-148 to 2300°F)
Type E:
-200 to 849°C (-328 to 1560°F)
Type T:
-200 to 400°C (-328 to 752°F)
Type R & S:
100 to 1760°C (212 to 3200°F)
T/C Accuracy:
0.5°C (0.9°F); 2.5°C (4.5°F) or 0.5% FS for R & S
RTD Input:
100Ω Platinum, 2 or 3 wire, 0.00385 curve
RTD Range:
-200 to 850°C (-328 to 1562°F)
RTD Accuracy:
0.5°C (0.9°F)
Process Input:
0 to 10 Vdc, 0 to 20 mA/ 4 to 20 mA
Process Accuracy:
0.1% of reading
Data Logging:
Up to 85,000 data points with time stamping
Logging Mode:
Stop When Full or Circular Buffer
Logging Start/Stop: Press key, alarm 1 or 2 on, alarm 1 or 2 off, time/date
Analog Output::
4 to 20 mA or 0/5 Vdc isolated
Relays:
SPDT, 250 Vac or 30 Vdc @ 3A
Alarm:
Enable/disable, high/low, latch/unlatch
Voltage Excitation: Isolated 24 Vdc @ 25 mA
PC Interface:
Isolated USB or RS232
RF Transmitter:
ISM 2.4 GHz, direct sequence spread spectrum, 10mW
RF Range:
Up to 40 m (130') indoors, 120 m (400') outdoors
Power:
90 to 240 Vac ±10%, 50 to 400 Hz
Isolation:
3000 Vac Power to I/O, 2300 Vac Power to relays
Operating Conditions: 0 to 50°C (32 to 122°F), 90% RH non-condensing
Dimensions:
48 H x 96 W x 118 mm D (1.89 x 3.78 x 4.65")