• Dual 4-digit LED displays for process & setpoint values
• User-friendly menus and tactile keypad
• Fuzzy Logic PID offers intuitive control
• Manual mode overrides automatic control
• One-touch Auto Tuning for quick setup and precise control
• Single stage Ramp and Soak program with
Ramp-to-Setpoint Limit
• Soft Start feature for smooth process start-up
• Accepts thermocouple and RTD inputs
• Select input type from display menu – no hardware change
• Two ‘Latching’ relays with 8 Alarm modes & advanced
Timer modes
Inputs
Type K
Type J
Type B
Type T
Type E
Type R, S
Type N
Type C
Pt100 RTD (DIN)
Pt100 RTD (JIS)
Control/Alarm Relay
DC Current Output
Accuracy
Sampling Time
LED Status
Control Modes
Front Panel
Power Supply
•
•
•
•
•
•
High Accuracy ±0.5°C, 0.03% Rdg.
Extended 5-Year Warranty
Universal Inputs
Relay, SSR, DC Pulse Outputs
Ramp to Setpoint
Universal Power Supply,
90–250 VAC or VDC
• Dual Output and Dual Alarm
• Optional RS-232, RS-485, Isolated
Analog Output or Remote Setpoint
CONTROLLERS
L
48VFL
Newport Autotune Process &
Temperature Controller
▲ ICN77
SPECIFICATIONS
Input
Input Types:
Thermocouple, RTD, analog voltage, analog current
Thermocouples: J, K, T, E, R, S, B, C, N, and J DIN
Accuracy:
±0.5°C temp; 0.03% rdg. process
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: ICN77-5-3-2-A2
A – B – C – D – E
SPECIFICATIONS
A
-58 to 2498°F (-50 to 1370°C)
-58 to 1832°F (-50 to 1000°C)
32 to 3272°F ( 0 to 1800°C)
-454 to 752°F (-270 to 400°C)
-58 to 1382°F (-50 to 750°C)
32 to 3182°F ( 0 to 1750°C)
-58 to 2372°F (-50 to 1300°C)
-58 to 3272°F (-50 to 1800°C)
-328 to 1652°F (-200 to 850°C)
-328 to 1202°F (-200 to 650°C)
5 Amp @ 110V, SPST (resistive load)
4-20mA (resistive); Impedance < 600 ohms
T/C: ±1.8°F (1°C); RTD: ±0.36°F (0.2°C)
4 samples per second
Alarm and Control output status
Fuzzy Logic enhanced three-term PID with Auto Tune
• Proportional Band 0 to 300.0%
• Integral time 0 to 3600 seconds
• Derivative time 0 to 900 seconds
• Hysteresis 0.0 to 200.0 or 0.0 to 2000
• Cycle time 1 to 100 seconds
Lexan, Drip/Dust proof, IP63
90 to 264 VAC; 50/60 Hz (< 5VA)
B
C
D
E
F
– F
Basic Unit
ICN77 1/16 DIN Controller
Configuration
5
NEMA-4/IP65 Face with DIN Cutout
R5
Square Bezel with 1 3/4" Round Cutout
Primary Output
2
SSR (1A @ 120/240 VAC)
3
SPDT Relay (5A @ 120 VAC)
4
Pulsed 0–10 VDC @ 20 mA Max
5
Non-isolated 1–10V or 0–20 mA
Second Output
0
None
2
SSR (1A @ 120/240 VAC)
3
SPDT Relay (5A @ 120 VAC)
4
Pulsed 0–10 VDC @ 20 mA Max
Options
A2
Second Alarm Relay
C2
Isolated RS-232
C4
Isolated RS-485
PV
Isolated Analog Output
RSP
Remote Setpoint
Optional Power–Include Only if Required
DC
10–34 VAC/VDC Power
ORDERING INFORMATION—ACCESSORIES
ORDERING INFORMATION
48VFL11
48VFL13
96VFL11
96VFL13
1/16 DIN Temperature PID Controller with one relay output
1/16 DIN Temperature PID Controller with 4-20mA output
1/4 DIN Temperature PID Controller with two relay outputs
1/4 DIN Temperature PID Controller with 4-20mA output
SPC-116-S
TP4
TP6
Splash-Proof Cover for 1/16 DIN Controllers
Trim Plate Adapter to Install 1/16 DIN
Meter in Existing 1/4 DIN Panel Cutout
Trim Plate Adapter to Install 1/16 DIN
Meter in Existing 1/8 DIN Panel Cutout
6