BG TriColor AC Power Circular BarGraphs 0 -20 +40 MEGAVARS -60 Watt, VAR and Power Factor Meters for Single and Three Phase Systems +20 -40 - 7 202 . -80 -100 +60 +80 +100 BG-261TC Center Zero 80 KW 120 I68.45 160 200 0 These Weschler BG TC Circular BarGraphs are optimized for AC power measurements. The ACP3 models include self contained CT (Current Transformers) and PT (Potential Transformers) plus accurate solid state circuitry to measure both single and poly phase applications. A self-contained instrument provides better accuracy than a separate transducer and meter. Weschler BarGraphs combine the visual indication of an analog meter with the precision of a digital instrument. Large digits and a wide viewing angle allow operators to easily monitor the signal from a distance. The ACP3 Watt and Varmeters can replace analog instruments such as the Weschler/Westinghouse KP-241, KP-261, KV-241 and KV261. The analog backplate option duplicates the Westinghouse terminal stud connections. The BG-241 and BG-261 panel footprint and mounting also match other 4½" and 8¾" switchboard meters such as the GE AB40, DB40, AB16 and DB16. GENERATOR #1 40 ACP3 BG-281TC Solid Bar Mode ACP3 BarGraph instruments are housed in a rugged steel case. They are designed for long life in utility switchboards and other control applications. Installation is also simplified with the ACP3 series. FEATURES 50 40 30 70 VAR 20 7 0.045 10 Large, high resolution 50 segment LED bar array 60 80 5 digit display with resolution to 0.01% 90 100 0 BG-281TC Banded Bar Mode 40 60 KW 20 80.00 0 Weschler 80 100 BG-241TC WESCHLER INSTRUMENTS DIVISION OF HUGHES CORPORATION 16900 FOLTZ PARKWAY - CLEVELAND, OH 44149 Phone: (440) 238-2550 - Fax: (440) 238-0660 www.weschler.com e-mail: sales@weschler.com Field programmable functions Zero and full scale point location Setpoint type (Hi or Low) Hysteresis & latching Setpoint time delay 16 step dimming Digital display for engineering units Enable/disable front buttons I.D. selection for communication Bar form Peak / Valley enable Color zones Over-range /Under-range flashing Lamp test Form-C relay outputs Normally Open Contact 5A, resistive @ 250V AC 5A, resistive @ 28V DC Normally Closed Contact 3A, resistive @ 250V AC 2A, resistive @ 28V DC Communication RS232/485, SCADA, DCS Analog retransmit 4-20, 0-1mA DC 1-5, 0-1, 0-5 V DC Retrofit sizes for: GE/Yokogawa AB/DB 40, 4½” and AB/DB 16 8¾" switchboard meters Peak and Valley hold Crompton 075/07, 4½" and 8¾" switchboard meters Trend indication for signal direction Ashcroft, Heise 8" gauges Dixson BW051/P Weschler K241, K261 SPECIFICATIONS Bar Display 50 segment LED 2% full scale resolution Circular display: 0 BG-241 285 0 BG-261/281 255 Setpoints Four SPDT relays with form C contacts available. Hysteresis 0.00-10.00% FS or latching. Time delay 0-10 sec. Digital Display 5 digit -9999 to 99999 Resolution 0.01% full scale Linearity ±1 count Retransmit Signals 4-20mA DC 0-1mA DC 1-5V DC 0-5V DC Height BG-241 BG-261/281 Communication RS232 RS485 (2-wire) 0.4" 0.8" (10.16mm) (20.32mm) Response Time AC <800msec full scale Input Impedance 30kohm @ 120V AC P.T. 0.1ohm @ 5A AC C.T. Input Isolation AC Transformer isolated (>50mA, 1V) Input Overload Ratings 200%, not to exceed 10 A 200%, not to exceed 300 V Input Range (RMS) MIN - MAX Current 1mA - 5A AC Voltage 50mV - 250V AC Power Accuracy 120/240V AC ±10% (13VA) Watt, VAR ±0.5% of full scale 12, 24, 28, 48, 250V DC ±10% (8W) Power Factor ±0.1 PF Temperature Operation 00 to 500C, <95% RH 110-250V DC (8W), (non-condensing) 85-264V AC (13VA) Storage -400 to 850C The Weschler ACP Power Series BarGraph is a self-contained instrument. Correct installation and connection is critical to the success of the application. Review the phaser diagrams to determine the proper configuration for your application, particularly in retrofit situations. Caution should be taken for VAR applications where historically many engineers have specified a Wattmeter, 90 degree phase shifter, and a VAR scaleplate. If your application has phase shifters in place and you wish to leave them in the circuit, you will need to order a WATT bargraph with a VAR scale. ARTWORK GUIDELINES 11 CHAR. 14 CHAR. 17 CHAR. X MULTIPLIER: 4 CHAR. FIELD IF REQUIRED BG- 241 4.5" (114.3 mm) SQUARE BG- 261 8.5" (215.9 mm) SQUARE BG- 281 8.5" (215.9 mm) ROUND ORDERING GUIDE Specify scale markings and legend when ordering TriColor ACP3 PART NUMBER TYPE: 4 = BG241 6 = BG261 8 = BG281 BAR COLOR: T = TriColor 4-1/2" Square BarGraph 8-3/4” Square BarGraph 8" Circle BarGraph BAR ZERO POINT: B = Zero at Bottom H = Zero at 50% mid scale F = Zero at F.S. S = Special /off scale zero DIGITAL DISPLAY: R = Red Y = Yellow G = Green S = Special INPUT TYPE: L = Watts single phase H = Watts three phase V = VARs single phase Z = VARs three phase Y = VARs three phase for external phase shifter (4-wire only) G = Power factor (display 1.00 max, specify lag on right or left) Specify: CT ratio _____________ Full scale Watts value ___________ PT ratio _____________ External phase shifter ___________ System Delta or WYE B Y 4 Analog Backplate Conformal Coating Custom Artwork Spraytight Front (BG241/261) None Special T X = = Trend Indicator NA P X = = Peak/Valley Hold NA RETRANSMIT: C = 1-5V DC (or 0-5V on request) D = 0-1V DC F = 4-20mA DC G = 0-1mA DC W = Excitation Power 24 VDC @ 90mA S = Special X = None SETPOINT HYSTERESIS: P = Programmable S = Special X = Not required 4 = = = = = = COMMUNICATION: A = RS232 C = RS485 Bi-directional X = None SETPOINT RELAYS: 4 = 4 Relays X = No relays S = Special order EXAMPLE: B K A Y X S P H 3 3 1 F A P T A T (4) BG-241, (B) zero at bottom, (Y) Yellow digits, (4) 4 relays, (P) Programmable setpoint hysteresis, (H) Watts input, (33) 3 phase, 3 wire, (1)120 VAC 50/60 Hz power, (F) 4-20 mA DC isolated retransmit, (A) RS232 communication, Options and features vary by model. Contact factory for details and latest specifications. POWER: 1 = 120V AC ±10% 50/60Hz 2 = 240V AC ±10% 50/60Hz 4 = 12V DC ±10% * 6 = 250VDC ±10% 7 = 24V DC ±10% 8 = 28V DC ±10% 9 = 48V DC ±10% U = 110-250V DC / 85-264V AC, 50-440Hz *Max ambient 45°C INPUT LEVEL: 12 = Single phase two wire 13 = Single phase three wire 33 = Three phase three wire 34 = Three phase four wire 3E = Three phase four wire WESCHLER INSTRUMENTS 1 element 2 element 2 element 2½ element 3 element 16900 FOLTZ PARKWAY - CLEVELAND, OH 44149 Phone: (440) 238-2550 - Fax: (440) 238-0660 www.weschler.com e-mail: sales@weschler.com DIMENSIONS BG-241 A* 0.687" 17.450 mm 4.421" 112.293 mm 1.687" 42.850 mm 0.315" DIA. (X4) 8.001 mm 1.687" 42.850 mm 1.687" 42.850 mm 3.960" 100.584mm 4.421" 112.293 mm 4.0" DIA. 101.6 mm 1.687" 42.850 mm FRONT VIEW SIDE VIEW PANEL CUTOUT (FOR BG241 / 261) BACK VIEW BG-261 8.750" 222.25 mm 1.015" 25.781 mm A* *Case Depth Extended 3.960" 100.584 mm 8.750" 222.25 mm A inches mm 5.150 126.17 Mounting Torque Requirements 65-70 inch-pounds maximum. FRONT VIEW SIDE VIEW BACK VIEW BG-281 1.015" 25.781 mm B DIM. B Inches (mm) A* 3.960" 100.584 mm 10.062 (246.52) DIM. C Inches (mm) DIM. D Inches (mm) 2.055-4.455R. (52.20-113.16) 1200 1200 4.754 R. (120.75) 0.312 DIA.TYP. 7.925 mm FRONT VIEW SIDE VIEW C D PANEL CUTOUT FOR BG-281 TERMINAL CONNECTIONS 3f 4W Wattmeter ALARMS HI C B A 3f 3W Wattmeter COMM LO ALARMS RX C Tx HI 2 4 3 5 6 3 2 1 HI HI -- LO LO 2 4 3 10 11 12 1 2 -- 8 3 2 1 10 11 12 6 7 C NO C 4 9 NC NC NO NO C 5 8 2 AC connections are screw terminals 1 10 11 12 1 + 3 7 6 7 3 9 2 3 ReXmit 5 8 NC 9 6 LO LO NO 8 RX C Tx 5 + HI HI 7 COMM LO 1 C 1 4 9 NC N C B A ReXmit 3 2 1 10 11 12 Options and features vary by model. Contact factory for details and latest specifications. LOAD - + BARGRAPH POWER LOAD - + BARGRAPH POWER 5/28/08