SmartRow Intelligent, Integrated Infrastructure Solution in A Row ™

advertisement
SmartRow™
Intelligent, Integrated Infrastructure Solution in A Row
Intelligent, Integrated Infrastructure Solution in A Row
SmartRow™ is a fully-integrated data center infrastructure
solution equipped with power, thermal management
and infrastructure management and monitoring solution
from Emerson Network Power. It is designed for indoor
environments such as small and medium sized data centers
or computer rooms. SmartRow™ can store 19’’ rack mount IT
hardware equipment such as server, storage and networking
devices. It features cabinets, closed aisle cooling system, power
distribution, and centralized infrastructure monitoring system.
Efficient
33 Reduces energy cost by
more than 30% through
better PUE
33 Optimizes space utilization
through an integrated
design
33 Order, install and implement
in just a few weeks
Intelligent
33 Single web-based intelligent
management interface
provides insight on power,
cooling, data center
environment enhances
operational reliability and
efficiency
Simplified
33 Pre-engineered
infrastructure for multiple
remote site deployment
33 Single system service for
startup, warranty, preventive
maintenance and repair
Application Scenarios
Infrastructure
Management
Thermal
Management
Monitoring
& Security
Power
Management
Racks & Integrated
Cabinets
Optional
Small Data Center/Computer
Room; Expanding Data Center
in growth
Floor:
Raised or non-raised floor
Access & Control
An optimized data center infrastructure leads to
lower CAPEX / OPEX and higher reliability.
Converged solution for complete data center
access & control management
Power Management Unit
„„Built-in Power Management
Unit (PMU) provides circuit
breakers to UPS, Cooling unit,
PDU, and maintenance bypass.
Cooling System
„„Integrated cooling unit
provides efficient thermal
management for closed aisle
space.
Optional: IT Management
Rack Server Access
„„Provide at-the-rack access
to servers, making software
upgrades, troubleshooting
and system monitoring
convenient and less time
consuming.
Remote Server and Serial
Management
„„The Universal
Management Gateway is
a converged management
solution that enables remote
management of any device
regardless of vendor, in any
location, at any time via
a secured and centralized
connection.
Monitoring and Management
System
„„With pre-defined operation
logics, it provides not only
notifications on environment
and equipment status, but also
management access to ensure
reliable system operations.
Cabinet and Closed Aisle
„„Accommodates the 19’’ rack
mount hardware equipment
which complies with industrystandards (EIA-310).
UPS and Power Distribution Unit
„„Provides reliable and highquality backup power for the
IT equipment with integrated
power distribution panel to
manage the power supply from
facility power to equipment.
SmartRow™ vs Traditional Computer Room Build
SmartRow
Traditional Computer Room
Number of Racks: 3
Total IT Load: 10KW
Density: 3.3KW / Rack
Room: 10m²
Cooling: 12KW
Power: 20KVA
Number of Racks: 3
Total IT Load: 10KW
Density: 3.3KW / Rack
Room: 20m²
Cooling: 20KW
Power: 20KVA
Conventional
SmartRow
Cost Savings
% Savings
40,000
50,000
-10,000
-25%
10,000
2,500
7,500
75%
12,000
7,500
4,500
38%
Total CapEx
62,000
60,000
2,000
3%
Room Rent
6,000
3,000
3,000
50%
50,370
32,230
18,140
36%
5 Year OpEx
281,850
176,150
105,700
37.5%
5 Year TCO
343,850
236,150
107,700
31.3%
Infrastructure Equipment
UPS, Distribution, Cooling, Racks, Fire Suppression
Computer Room Build
UPS, Distribution, Cooling, Racks, Fire Suppression
Project Management &
Site Commissioning
UPS, Distribution, Cooling, Racks, Fire Suppression
Approx.25USD / m²
Annual Energy Consumption
Power & Cooling equipment energy use $0.23/KWH
Space Savings
Requires less space and
minimum site preparation
through integrated design
Equipment Savings
Pre-engineered, integrated
thermal management, and
power distribution
Energy Savings
Requires less space and
minimum site preparation
through integrated design
SmartRow’s advanced cooling systems
significantly increase energy efficiency
Closed
Cold Aisle
Applicable to room size > 20m²
Closed
Hot Aisle
Applicable to room size at about 20m²
SmartRow™ vs Traditional Computer Room Build
Features
SmartRow­™
Complete, Integrated
Infrastructure
Industry leading design. All products integrated in the system-thermal management,
monitoring, racks, optional UPS/Power Distribution and rack PDUs-work together to optimize
capacity, efficiency and availability.
Incorporate Industry
Best Practices
Employs best practices known to work well in top-performing data centers:
„„Hot aisle / cold aisle separation
„„High availability, high efficiency UPS
„„Highest efficiency cooling
„„Space-saving, minimal footprint
„„Modularity for flexibility and easier expansion
„„Integrated monitoring and control for efficiency in planning and management
„„Reliable local service
Lower Capital
Expense
Lower Operating
Expense
Compact Footprint
Achieve greater savings compare to traditional build with dedicated cooling, raised floor and
other conventional data center requirements.
Better PUE reduces energy cost by more than 30%
Integrated design occupies less floor space and reduces costs.
Quick Installation
Easily deployable and ready to use within weeks.
Simplified Project
Management
Network of local data center experts and service teams make ordering, installing and
servicing the SmartRow solution easy.
Flexibility
Monitoring and
Management
2-4 racks, 12 kW cooling capacity with redundancy options; ability to scale power, cooling
and monitoring management all within existing architecture
Integrated monitoring and alarm systems work together to provide greater control over
the IT environment.
Features
Traditional Computer Room
Complete, Integrated
Infrastructure
Multiple and varying infrastructure components must be ordered and installed separately
which can result to system incompatibility resulting to inefficiency.
Incorporate Industry
Best Practices
Infrastructure components may not be designed and configured for best practices to optimize
performance.
Lower Capital
Expense
Lower Operating
Expense
Compact Footprint
Additions or overhaul of room-level power, cooling and distribution needed to accomodate
more IT equipment
Independent cooling equipment may be less efficient because the entire room temperature and
humidity must be managed
Perimeter cooling and other infrastructure may require greater space utilization. Cooling
will require more airflow making it less efficient; power distribution will require multiple
distribution panels
Quick Installation
Installation is complex with cascading requirements, longer timeframes, and multiple outside
technicians required
Simplified Project
Management
Service and support from multiple vendors may be complicated
Flexibility
Monitoring and
Management
Difficult to change airflow or add air capacity, as well as to add power capacity
Monitoring and management are available, but may not be integrated across infrastructure
components as turn-key solution.
Intelligent Monitoring Platform
with Remote Access for Management
1
4
2
5
3
6
1
2 3
4
5
6
Centralized management can be achieved by RDU-M platform
to manage branch applications across the regions
SmartRow Infrastructure Management with RDU-A G2
„„Web UI defined by User
„„Real-time monitoring
and status display
„„Alarm setting and
notification
„„Facility equipment
remote management
„„Report and trending
analysis
„„Instant configuration
software package
(available for 4 standard
scenarios)
„„Scalable platform for
business growth
Manage Environments and
Security of Data Center with RDU-A G2
The Liebert® RDU-A G2 is an infrastructure management solution from Emerson Network Power that allows data center
administrators to manage environmental conditions (i.e. temperature and humidity, leak, smoke, vibrations and digital
inputs and outputs.) It is also capable of monitoring infrastructure appliances such as UPS, Thermal Management units,
generator sets, etc. The Liebert® RDU-A G2 is equipped with a built-in web server, eliminating the need to perform a
software installation.
Console Port
LEGEND:
USB
Power Input 1
100~240VAC
USB Camera /
Modem Port
Power Input 2
n Modbus 485 Com Port
100~240VAC
n Environmental Sensor Port
n Contact Closure Output Port
n Ethernet and SNMP Port
COM Port 3 (2 ports)
COM Port 1, 2
Network Port 1 and 2
Sensor Port 1 (2 ports)
Sensor Port 2 (2 ports)
10/100Mbps
Relay Output 1 and 2
+12Vdc @ 0.2A
Digital Input 1 and 2
+12Vdc @ 0.1A
2 Slots for optional
4COM Port Card / 8DIAI
Card / 8DOAO Card
+12Vdc @ 0.2A
Smoke Sensor Port 1 and 2
+12Vdc @ 0.1A
The Liebert® RDU-A G2 allows data
center managers to perform the
following operations through a secure
web page:
„„ M
onitoring of the health and status of the
equipment
„„ Monitoring of environmental conditions (i.e.
temperature and humidity, leak and smoke.)
„„ Monitor the improved communication speed
in transmitting control or commands to the
equipment and parameter setting
„„ Records Data and Logs of historical information
of alarms and notifications
3rd Party
Communications:
„„
„„
„„
„„
SNMP
Modbus 485
Dry contacts
Analog Signals
Specifications
Cabinet and Closed Aisle
Closed cabinet (H x W x D)
2000mm (42U) x 600mm x 1100mm
Max mounting depth
784 mm (inside the closed cabinet)
Closed aisle (H x W x D)
2000mm (42U) x 600mm x 300mm
Power
Power load
20kVA
UPS topology
On-line double conversion
Rate input voltage
380/400/415 VAC, 3-phase, 4-wire
system
Rate input frequency
50/60Hz
Input voltage range
3-phase, 228V-478V
Input frequency range
40Hz-70Hz
Input power factor
Full load>0.99, half load >0.98
Rate output voltage
3-phase, 380/400/415Vac; 1-phase,
220/230/240Vac
Rate output frequency
50/60Hz
Rate output power
20KVA/18KW
Load crest Factor
3:1
Overload capacity performance
(% rated load)
105%-125% 5mins, 125%-150% 1min,
>150% 200mS
System efficiency
Up to 94%
Power management unit
Available. PMU is included.
(with maintenance bypass)
Closed Cold Aisle | Room size > 20m²
Thermal Management
Cooling type
Air-cooled / DX. Thermal Management
Cooling capacity (KW)
12kW
Input voltage / frequency
400V / 50Hz or 60Hz
Refrigerant
R22
Monitoring
Platform unit
RDU-A G2
System Operation
Working environmental
Indoor: 0°C ~ 40°C / 30%RH ~ 80%RH
Outdoor: standard model, -15°C ~
+45°C; Lee-Temp model, -34°C ~ +45°C
Closed Hot Aisle | Room size at about 20m²
SmartRow™ 1 + 2 (One cooling cabinet + two IT cabinets)
Specification
Dimension(mm)
WxDxH
Cold Aisle Closed
Hot Aisle Closed
1800 x 1400 x 2000
2000 x 1400 x 2000 (1 x networking cabinet)
Usable U
74U
Cooling kW
12kW (total) / 6kW per cabinet
Redundancy
No
SmartRow™ 1 + 3 (One cooling cabinet + Three IT cabinets)
Specification
Dimension(mm)
WxDxH
Cold Aisle Closed
Hot Aisle Closed
2400 x 1400 x 2000
2600 x 1400 x 2000 (1 x networking cabinet)
Usable U
116U
Cooling kW
12kW (total) / 4kW per cabinet
Redundancy
No
SmartRow™ 2 + 3 (Two cooling cabinets (1+1) + Three IT cabinets)
Specification
Cold Aisle Closed
Hot Aisle Closed
Dimension(mm)
WxDxH
3000 x 1400 x 2000
Usable U
116U
Cooling kW
12kW (total) / 4kW per cabinet
Redundancy
Redundant Cooling Design
3200 x 1400 x 2000 (1 x networking cabinet)
SmartRow™ 2 + 4 (Two cooling cabinets (1+1) + Four IT cabinets)
Specification
Cold Aisle Closed
Hot Aisle Closed
Dimension(mm)
WxDxH
3600 x 1400 x 2000
Usable U
158U
Cooling kW
12kW (total) / 3kW per cabinet
Redundancy
Redundant Cooling Design
3800 x 1400 x 2000 (1 x networking cabinet)
More options:
1. Cabinet Solution: Cabinet in 2000mm(42U) x 800mm x 1100mm is available for networking
application; the conventional accessories like blanking panels, cable management , shelves are also
available with standard offering
2. Power Solution: Redundancy power system solution, battery and PDUs are available with standard
offering
3. Monitoring Solution: more options on environmental sensors are available. For those SmartRow
deployed in distributed location, a central facility management platform–RDU-M is available with
more sophisticated management functions
Emerson Network Power Asia
Australia
T: 1800-065345
F: 61-2-97438737
Pakistan
T: 92-42-36622526 to 28
F: 92-42-36622530
Indonesia
T: 62-21-2513003
F: 62-21-2510622
Philippines
T: 63-2-7207400
F: 63-2-6203693
Japan
T: 81-3-54038564
F: 81-3-54032919
Singapore
T: 65-64672211
F: 65-64670130
Korea
T: 82-2-34831500
F: 82-2-5927886
Thailand
T: 66-2-6178260
F: 66-2-6178277 to 78
Malaysia
T: 603-78845000
F: 603-78845188
Vietnam
T: 84-4-37628908
F: 84-4-37628909
New Zealand
T: 64-3-3392060
F: 64-3-3392063
While every precaution has been taken to ensure
accuracy and completeness herein, Emerson
Network Power assumes no responsibility, and
disclaims all liability, for damages resulting
from use of this information or for any errors or
omissions. Specifications are subject to change
without notice.
Emerson Network Power and the Emerson
Network Power Logo are trademarks of Emerson
Electric Co. or one of its affiliated companies.
All other names and logos referred to are trade
names, trademarks, or registered trademarks of
their respective owners.
©2015 Emerson Electric Co. All right reserves
AP15ENT-SmartRowV1-BR
Stay connected:
Marketing.ap@emerson.com
www.EmersonNetworkPower.Asia
Download