SmartRow™ Intelligent, Integrated Infrastructure Solution in A Row Intelligent, Integrated Infrastructure Solution in A Row SmartRow™ is a fully-integrated data center infrastructure solution equipped with power, thermal management and infrastructure management and monitoring solution from Emerson Network Power. It is designed for indoor environments such as small and medium sized data centers or computer rooms. SmartRow™ can store 19’’ rack mount IT hardware equipment such as server, storage and networking devices. It features cabinets, closed aisle cooling system, power distribution, and centralized infrastructure monitoring system. Efficient 33 Reduces energy cost by more than 30% through better PUE 33 Optimizes space utilization through an integrated design 33 Order, install and implement in just a few weeks Intelligent 33 Single web-based intelligent management interface provides insight on power, cooling, data center environment enhances operational reliability and efficiency Simplified 33 Pre-engineered infrastructure for multiple remote site deployment 33 Single system service for startup, warranty, preventive maintenance and repair Application Scenarios Infrastructure Management Thermal Management Monitoring & Security Power Management Racks & Integrated Cabinets Optional Small Data Center/Computer Room; Expanding Data Center in growth Floor: Raised or non-raised floor Access & Control An optimized data center infrastructure leads to lower CAPEX / OPEX and higher reliability. Converged solution for complete data center access & control management Power Management Unit Built-in Power Management Unit (PMU) provides circuit breakers to UPS, Cooling unit, PDU, and maintenance bypass. Cooling System Integrated cooling unit provides efficient thermal management for closed aisle space. Optional: IT Management Rack Server Access Provide at-the-rack access to servers, making software upgrades, troubleshooting and system monitoring convenient and less time consuming. Remote Server and Serial Management The Universal Management Gateway is a converged management solution that enables remote management of any device regardless of vendor, in any location, at any time via a secured and centralized connection. Monitoring and Management System With pre-defined operation logics, it provides not only notifications on environment and equipment status, but also management access to ensure reliable system operations. Cabinet and Closed Aisle Accommodates the 19’’ rack mount hardware equipment which complies with industrystandards (EIA-310). UPS and Power Distribution Unit Provides reliable and highquality backup power for the IT equipment with integrated power distribution panel to manage the power supply from facility power to equipment. SmartRow™ vs Traditional Computer Room Build SmartRow Traditional Computer Room Number of Racks: 3 Total IT Load: 10KW Density: 3.3KW / Rack Room: 10m² Cooling: 12KW Power: 20KVA Number of Racks: 3 Total IT Load: 10KW Density: 3.3KW / Rack Room: 20m² Cooling: 20KW Power: 20KVA Conventional SmartRow Cost Savings % Savings 40,000 50,000 -10,000 -25% 10,000 2,500 7,500 75% 12,000 7,500 4,500 38% Total CapEx 62,000 60,000 2,000 3% Room Rent 6,000 3,000 3,000 50% 50,370 32,230 18,140 36% 5 Year OpEx 281,850 176,150 105,700 37.5% 5 Year TCO 343,850 236,150 107,700 31.3% Infrastructure Equipment UPS, Distribution, Cooling, Racks, Fire Suppression Computer Room Build UPS, Distribution, Cooling, Racks, Fire Suppression Project Management & Site Commissioning UPS, Distribution, Cooling, Racks, Fire Suppression Approx.25USD / m² Annual Energy Consumption Power & Cooling equipment energy use $0.23/KWH Space Savings Requires less space and minimum site preparation through integrated design Equipment Savings Pre-engineered, integrated thermal management, and power distribution Energy Savings Requires less space and minimum site preparation through integrated design SmartRow’s advanced cooling systems significantly increase energy efficiency Closed Cold Aisle Applicable to room size > 20m² Closed Hot Aisle Applicable to room size at about 20m² SmartRow™ vs Traditional Computer Room Build Features SmartRow­™ Complete, Integrated Infrastructure Industry leading design. All products integrated in the system-thermal management, monitoring, racks, optional UPS/Power Distribution and rack PDUs-work together to optimize capacity, efficiency and availability. Incorporate Industry Best Practices Employs best practices known to work well in top-performing data centers: Hot aisle / cold aisle separation High availability, high efficiency UPS Highest efficiency cooling Space-saving, minimal footprint Modularity for flexibility and easier expansion Integrated monitoring and control for efficiency in planning and management Reliable local service Lower Capital Expense Lower Operating Expense Compact Footprint Achieve greater savings compare to traditional build with dedicated cooling, raised floor and other conventional data center requirements. Better PUE reduces energy cost by more than 30% Integrated design occupies less floor space and reduces costs. Quick Installation Easily deployable and ready to use within weeks. Simplified Project Management Network of local data center experts and service teams make ordering, installing and servicing the SmartRow solution easy. Flexibility Monitoring and Management 2-4 racks, 12 kW cooling capacity with redundancy options; ability to scale power, cooling and monitoring management all within existing architecture Integrated monitoring and alarm systems work together to provide greater control over the IT environment. Features Traditional Computer Room Complete, Integrated Infrastructure Multiple and varying infrastructure components must be ordered and installed separately which can result to system incompatibility resulting to inefficiency. Incorporate Industry Best Practices Infrastructure components may not be designed and configured for best practices to optimize performance. Lower Capital Expense Lower Operating Expense Compact Footprint Additions or overhaul of room-level power, cooling and distribution needed to accomodate more IT equipment Independent cooling equipment may be less efficient because the entire room temperature and humidity must be managed Perimeter cooling and other infrastructure may require greater space utilization. Cooling will require more airflow making it less efficient; power distribution will require multiple distribution panels Quick Installation Installation is complex with cascading requirements, longer timeframes, and multiple outside technicians required Simplified Project Management Service and support from multiple vendors may be complicated Flexibility Monitoring and Management Difficult to change airflow or add air capacity, as well as to add power capacity Monitoring and management are available, but may not be integrated across infrastructure components as turn-key solution. Intelligent Monitoring Platform with Remote Access for Management 1 4 2 5 3 6 1 2 3 4 5 6 Centralized management can be achieved by RDU-M platform to manage branch applications across the regions SmartRow Infrastructure Management with RDU-A G2 Web UI defined by User Real-time monitoring and status display Alarm setting and notification Facility equipment remote management Report and trending analysis Instant configuration software package (available for 4 standard scenarios) Scalable platform for business growth Manage Environments and Security of Data Center with RDU-A G2 The Liebert® RDU-A G2 is an infrastructure management solution from Emerson Network Power that allows data center administrators to manage environmental conditions (i.e. temperature and humidity, leak, smoke, vibrations and digital inputs and outputs.) It is also capable of monitoring infrastructure appliances such as UPS, Thermal Management units, generator sets, etc. The Liebert® RDU-A G2 is equipped with a built-in web server, eliminating the need to perform a software installation. Console Port LEGEND: USB Power Input 1 100~240VAC USB Camera / Modem Port Power Input 2 n Modbus 485 Com Port 100~240VAC n Environmental Sensor Port n Contact Closure Output Port n Ethernet and SNMP Port COM Port 3 (2 ports) COM Port 1, 2 Network Port 1 and 2 Sensor Port 1 (2 ports) Sensor Port 2 (2 ports) 10/100Mbps Relay Output 1 and 2 +12Vdc @ 0.2A Digital Input 1 and 2 +12Vdc @ 0.1A 2 Slots for optional 4COM Port Card / 8DIAI Card / 8DOAO Card +12Vdc @ 0.2A Smoke Sensor Port 1 and 2 +12Vdc @ 0.1A The Liebert® RDU-A G2 allows data center managers to perform the following operations through a secure web page: M onitoring of the health and status of the equipment Monitoring of environmental conditions (i.e. temperature and humidity, leak and smoke.) Monitor the improved communication speed in transmitting control or commands to the equipment and parameter setting Records Data and Logs of historical information of alarms and notifications 3rd Party Communications: SNMP Modbus 485 Dry contacts Analog Signals Specifications Cabinet and Closed Aisle Closed cabinet (H x W x D) 2000mm (42U) x 600mm x 1100mm Max mounting depth 784 mm (inside the closed cabinet) Closed aisle (H x W x D) 2000mm (42U) x 600mm x 300mm Power Power load 20kVA UPS topology On-line double conversion Rate input voltage 380/400/415 VAC, 3-phase, 4-wire system Rate input frequency 50/60Hz Input voltage range 3-phase, 228V-478V Input frequency range 40Hz-70Hz Input power factor Full load>0.99, half load >0.98 Rate output voltage 3-phase, 380/400/415Vac; 1-phase, 220/230/240Vac Rate output frequency 50/60Hz Rate output power 20KVA/18KW Load crest Factor 3:1 Overload capacity performance (% rated load) 105%-125% 5mins, 125%-150% 1min, >150% 200mS System efficiency Up to 94% Power management unit Available. PMU is included. (with maintenance bypass) Closed Cold Aisle | Room size > 20m² Thermal Management Cooling type Air-cooled / DX. Thermal Management Cooling capacity (KW) 12kW Input voltage / frequency 400V / 50Hz or 60Hz Refrigerant R22 Monitoring Platform unit RDU-A G2 System Operation Working environmental Indoor: 0°C ~ 40°C / 30%RH ~ 80%RH Outdoor: standard model, -15°C ~ +45°C; Lee-Temp model, -34°C ~ +45°C Closed Hot Aisle | Room size at about 20m² SmartRow™ 1 + 2 (One cooling cabinet + two IT cabinets) Specification Dimension(mm) WxDxH Cold Aisle Closed Hot Aisle Closed 1800 x 1400 x 2000 2000 x 1400 x 2000 (1 x networking cabinet) Usable U 74U Cooling kW 12kW (total) / 6kW per cabinet Redundancy No SmartRow™ 1 + 3 (One cooling cabinet + Three IT cabinets) Specification Dimension(mm) WxDxH Cold Aisle Closed Hot Aisle Closed 2400 x 1400 x 2000 2600 x 1400 x 2000 (1 x networking cabinet) Usable U 116U Cooling kW 12kW (total) / 4kW per cabinet Redundancy No SmartRow™ 2 + 3 (Two cooling cabinets (1+1) + Three IT cabinets) Specification Cold Aisle Closed Hot Aisle Closed Dimension(mm) WxDxH 3000 x 1400 x 2000 Usable U 116U Cooling kW 12kW (total) / 4kW per cabinet Redundancy Redundant Cooling Design 3200 x 1400 x 2000 (1 x networking cabinet) SmartRow™ 2 + 4 (Two cooling cabinets (1+1) + Four IT cabinets) Specification Cold Aisle Closed Hot Aisle Closed Dimension(mm) WxDxH 3600 x 1400 x 2000 Usable U 158U Cooling kW 12kW (total) / 3kW per cabinet Redundancy Redundant Cooling Design 3800 x 1400 x 2000 (1 x networking cabinet) More options: 1. Cabinet Solution: Cabinet in 2000mm(42U) x 800mm x 1100mm is available for networking application; the conventional accessories like blanking panels, cable management , shelves are also available with standard offering 2. Power Solution: Redundancy power system solution, battery and PDUs are available with standard offering 3. Monitoring Solution: more options on environmental sensors are available. For those SmartRow deployed in distributed location, a central facility management platform–RDU-M is available with more sophisticated management functions Emerson Network Power Asia Australia T: 1800-065345 F: 61-2-97438737 Pakistan T: 92-42-36622526 to 28 F: 92-42-36622530 Indonesia T: 62-21-2513003 F: 62-21-2510622 Philippines T: 63-2-7207400 F: 63-2-6203693 Japan T: 81-3-54038564 F: 81-3-54032919 Singapore T: 65-64672211 F: 65-64670130 Korea T: 82-2-34831500 F: 82-2-5927886 Thailand T: 66-2-6178260 F: 66-2-6178277 to 78 Malaysia T: 603-78845000 F: 603-78845188 Vietnam T: 84-4-37628908 F: 84-4-37628909 New Zealand T: 64-3-3392060 F: 64-3-3392063 While every precaution has been taken to ensure accuracy and completeness herein, Emerson Network Power assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. Emerson Network Power and the Emerson Network Power Logo are trademarks of Emerson Electric Co. or one of its affiliated companies. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. ©2015 Emerson Electric Co. All right reserves AP15ENT-SmartRowV1-BR Stay connected: Marketing.ap@emerson.com www.EmersonNetworkPower.Asia