Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Flotrex* HR Pleated Filters with Halar (ECTFE) Microfiber folio includes filters for every stage of processing, and we offer custom solutions for your unique applications. GE Water & Process Technologies is your complete source for filters, crossflow membranes, housings, and other filtration equipment. Typical Applications FHR all-Halar, melt-blown fiber filters offer outstanding performance in extremely harsh chemical environments. These FHR filters also provide costeffective, absolute filtration at high flow rates. Available in a range of 3, 10 and 25 µm, FHR filters are manufactured and packaged in a cleanroom environment for assured cleanliness. FHR filters are designed for both pre- and final filtration. Typical applications include: Figure 1: Flotrex HR Pleated Filters • Filtration of aggressive chemicals including Toluene and Xylene Description and Use • Filtration of Ozonated Water • Beverage Flotrex-HR (FHR) filters (Figure 1) are made entirely from Halar (ECTFE) (Halar is a trademark of Ausimont.), an industrial-grade fluoropolymer with excellent solvent resistance. FHR filters can withstand the harshest process conditions due to this virtually indestructible material. Providing broad chemical compatibility, you can count on our filters to produce consistent, uniform process streams in your most demanding filtration applications. FHR filters deliver high flow rates and high-purity results with absolute rated efficiencies (99.9% filtration efficiency at rated pore size based on ASTM F795 and F661 test methods) and retention characteristics that typically outperform polypropylene fiber filters. General Properties Flotrex-HR filters are available the following absolute pore size micron ratings: 3, 10 and 25 µm. Tables 1, 2, 3 and 4 show further details on materials of construction, dimensions, operational limits and flow performance. Table 1: Materials of Construction Description Material of Construction Media Halar Microfiber Support Layers Halar Core and Cage Halar Endcaps and Adapters Halar The FHR filter is just one example of our strong commitment to fluid treatment. Our complete portand clicking on “Contact Us” . * Trademark of General Electric Company; may be registered in one or more countries. ©2008, General Electric Company. All rights reserved. FS1091EN Jul-08 Additional Information Table 2: Dimensions Nominal O.D. Nominal I.D. Effective Filtration Area 2.75” (70 mm) 1.25” (31 mm) 8.0 ft2 (0.74 m2) • Flotrex-HR filters may be sanitized with compatible chemical agents such as ozonated water. The filters must not be autoclaved or steam sterilized. • Flotrex-HR filters meet the test criteria for USP24 class VI-121°C plastics and pass the MEM Elution Cytotoxicity Test. • Aqueous extracts from Flotrex-HR filters contains less than 0.25 EU/ml. The filters typically exhibit low levels of non-volatile residues. FHR filters are ozone tolerant for 9,000 ppm/hr with no extractables. • Table 5 provides more information on ordering Flotrex HR filters. Table 3: Operational Limits Description Operational Limits Maximum Forward Differential Pressure 60 psi (4.1 bar) at 70ºF (21ºC) Maximum Reverse Differential Pressure 30 psi (2.1 bar) at 70ºF (21ºC) Maximum Operating Temperature 180ºF (82ºC) at 10 psid (0.69 bar) in water Table 4: Flow Performance in Clean Water1 10 µm 25 µm 1 Data based on 10” length filter Table 5: Ordering Information Type Absolute Micron Rating Nominal Cartridge Length End #1 Adapter End #2 Adapter Elastomer Material FHR 03 = 3.0 µm 1 = 10 in (25 cm) A = Open End Gasket A = Open End Gasket V = Viton2 µm4 2 = 20 in (51 cm) E = 222 O-Ring G = Closed End Cap T = Teflon2 3 = 30 in (76 cm) F = 226 O-Ring H = Fin Adapter 10 = 10 25 = 25 µm Encapsulated Viton 4 = 40 in (102 cm) 2 Viton and Teflon are registered trademarks of DuPont. Lenntech Page 2 info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 FS1091EN Jul-08 The below GE ‐series cartridge filters are all the models that are potentially possible in all variations. Please note that not all models are actually produced or on stock and some model numbers and names have become obsolete. Nevertheless this should help as cross reference table chart for GE filters nomenclature. Flotrex HR FHR031AA FHR031AG FHR031AH FHR031EA FHR031EG FHR031EH FHR031FA FHR031FG FHR031FH FHR032AA FHR032AG FHR032AH FHR032EA FHR032EG FHR032EH FHR032FA FHR032FG FHR032FH FHR033AA FHR033AG FHR033AH FHR033EA FHR033EG FHR033EH FHR033FA FHR033FG FHR033FH FHR034AA FHR034AG FHR034AH FHR034EA FHR034EG FHR034EH FHR034FA FHR034FG FHR034FH FHR101AA FHR101AG FHR101AH FHR101EA FHR101EG FHR101EH FHR101FA FHR101FG FHR101FH FHR102AA FHR102AG FHR102AH FHR102EA FHR102EG FHR102EH FHR102FA FHR102FG FHR102FH FHR103AA FHR103AG FHR103AH FHR103EA FHR103EG FHR103EH FHR103FA FHR103FG FHR103FH FHR104AA FHR104AG FHR104AH FHR104EA FHR104EG FHR104EH FHR104FA FHR104FG FHR104FH FHR251AA FHR251AG FHR251AH FHR251EA FHR251EG FHR251EH FHR251FA FHR251FG FHR251FH FHR252AA FHR252AG FHR252AH FHR252EA FHR252EG FHR252EH FHR252FA FHR252FG FHR252FH FHR253AA FHR253AG FHR253AH FHR253EA FHR253EG FHR253EH FHR253FA FHR253FG FHR253FH FHR254AA FHR254AG FHR254AH FHR254EA FHR254EG FHR254EH FHR254FA FHR254FG FHR254FH Lenntech B.V. T +31‐15‐261.09.00 F +31‐15‐261.62.89 info@lenntech.com www.lenntech.com Rotterdamseweg 402 1225204 1233014 1226460 1232376 1227828 1228814 1227663 1231426 1221721 1223350 1231966 1220305 1220317 1233078 1223080 1228322 1220329 1220332 1233351 2629HH Delft FHR031AAE FHR031EGT FHR031EHT FHR031EHU FHR031FHT FHR032AAV FHR032EGT FHR032FHT FHR033FHT FHR101EGT FHR101EGV FHR101EHT FHR101FHT FHR102EGV FHR103EGV FHR103FHV FHR104EHT FHR251EHT FHR251FHV Netherlands