Flat Sheet Membrane Chart Note:

advertisement
Lenntech
info@lenntech.com Tel. +31-152-610-900
www.lenntech.com Fax. +31-152-616-289
Flat Sheet Membrane Chart
Note: This chart shows preliminary information, as GE is constantly doing research and developing new
membranes. As a result, new membranes will become available and old may be discontinued.
Cellulosic Membranes RO & NF
Model Class
1 Ft²
CD
CE
CK
1231224
1117302
1156753
RO
RO
NF
Pre-cut
Sepa Cell
5/pk
NA
1144469
1156755
Reject.
NaCl %
Ave.
98.5
97
92 (Na2SO4)
Cut-Off
Max P
Bar
pH
25C
N/A
N/A
2K
31
31
15
2-8
2-8
2-8
Typical
flux/psi
gfd@psi
15/420
23.5/420
28/220
Chlorine
ppm
continous
1
1
1
Max.
Temp.
°C
30
30
30
Typical
flux/psi
gfd@psi
15/800
22/800
26/225
26/225
26/115
Chlorine
ppm.hr
Max.
Temp
°C
70
70
70
70
70
Chlorine
ppm.day
none
none
none
none
none
none
Max.
Temp.
°C
80
80
80
80
50
70
20-50
20-50
1000
70
70
70
Polyamide Membranes RO
Model Class
1 Ft²
AD
AE
AG LF
AG
AK
3059507
3059508
3099081
1206368
1206374
RO
RO
RO
RO
RO
Pre-cut
Sepa Cell
5/pk
1221914
3059570
NA
1221916
1221917
Rejection
NaCl %
MWCO
Max P
Bar
pH
25C
99.75
99.8
99.5
99.5
99.0
N/A
N/A
N/A
N/A
N/A
80
80
80
40
20
1-11
1-11
1-11
1-11
1-11
1000
1000
1000
1000
1000
Proprietary Thin Film Membranes RO, NF, UF
Model Class
1 Ft²
Rejection
NaCl %
MWCO
Max P
Bar
pH
25C
1206364
1206354
1206296
1206320
1206292
3044180
Pre-cut
Sepa Cell
5/pk
1221919
1221920
1221921
1221922
1221923
NA
98.9
98.2
98%-MgSO4
96%-MgSO4
95%-MgSO4
96%-MgSO4
N/A
N/A
80
40
40
40
40
40
1-11
1-11
2-10
2-10
3-9
0-10
Typical
flux/psi
gfd@psi
22/425
22/225
22/100
31/100
39/100
8/100
SE
SG
DK
DL
HL
KH
RO
RO
NF
NF
NF
NF
GE
GH
GK
UF
UF
UF
1206355
1206356
1206357
3002314
1221924
1221925
None
None
None
40
27
27
1-11
1-11
1-11
20/400
20/150
17/75
150-300
on sucrose &
glucose
1K-PEG
2K-PEG
3K-PEG
Polyethersulfone / Polysulfone Membranes UF
Model Class
1 Ft²
PW
PT
PU
1206353
1221934
3033509
1MWCO
UF
UF
UF
Pre-cut
Sepa Cell
5/pk
1221929
1221932
3033508
Rejection
NaCl %
MWCO
dextran
Max P
Bar
pH
25C
None
None
None
20 K1
5K
10 K
10
10
10
1-11
1-11
1-11
Pre-cut
Sepa Cell
5/pk
1221931
Rejection
NaCl %
MWCO
Max P
Bar
pH
25C
None
0.3 µm
5
1-11
Pre-cut
Sepa Cell
5/pk
1221962
Rejection
NaCl %
MWCO
Max P
Bar
pH
25C
None
50 K
proteins
7
2-9
Typical
flux/psi
gfd@psi
85/30
90/50
85/30
Chlorine
ppm.day
Typical
flux/psi
gfd@psi
130/30
Chlorine
ppm.day
Typical
flux/psi
gfd@psi
176/20
Chlorine
ppm
5000
5000
5000
Max.
Temp.
°C
70
70
70
rating based on protein
PVDF Membranes UF & MF
Model
Class
1 Ft²
JX
MF
1206351
5000
Max.
Temp.
°C
70
Ultrafillic Membranes UF
Model Type
1 Ft²
MW
1221961
Ultrafillic
25
Max.
Temp.
°C
80
Assortments
Class
Designation
SEPA Cell 19 cm x 14 cm
(7.5” x 5.5”) 5/pk Part #
RO
NF
UF
Assortment (AG, AK, CE, SG, SE)
Assortment (CK, DK, DL, HL, GE)
Assortment (MW, PW, PT, GK, JX)
1155408
1155409
1155410
Within most membrane designations, several different membrane elements are available, that are differentiated by numbers after the membrane designation mentioned here.
These membranes are available in the following configurations:
1. pre-cut flat sheets for Sepa test cells
2. flat sheets of 1 ft² each (924 cm²) in 12”x12” size
3. spiral wound modules
Contact GE to know the construction size available for each polymer type.
Flat sheet membranes are not available in large quantities except under special arrangements.
Compatibility with Chemicals
Type-…
CA
PA
PS/PES
PVDF
PAN
Aliphatic Solvent
excellent
excellent
excellent
excellent
excellent
Alcohols
fair
good
excellent
good
excellent
Ester Ketone
poor
poor
poor
poor
excellent
Aromatic
poor
poor
poor
excellent
excellent
Weak Bases
poor
good
excellent
excellent
good
Weak Acids
fair
excellent
excellent
excellent
excellent
Strong Bases
poor
poor
fair
fair
fair
Strong Acids
poor
good
excellent
excellent
good
Oxidants
fair
poor
good
good
good
Aprotic Solv.
poor
poor
poor
poor
poor
The above is made in lieu of all other warranties expressed or implied. Manufacturers and sellers only obligation shall be to issue credit against the purchase or replacement of such quantity of the membrane elements
proved to be defective in material or workmanship. Neither manufacturer nor seller shall be liable for any
injury, loss or damage, direct or indirect, special or consequential, arising out of the use of misuse or inability
to use such product. The information contained herein is based on technical data and tests which we believe
to be reliable and is intended for use by persons having technical skill at their discretion and risk. Since the
conditions of use outside GE’s control, we can assume no liability whatsoever for results obtained or damages incurred through the application of the data presented. This information is not intended as a license to
operate under, or a manufacturer.
Lenntech
info@lenntech.com Tel. +31-152-610-900
www.lenntech.com Fax. +31-152-616-289
Download