Critical Infrastructure Assessments Critical Infrastructure Assessments Professional insight delivered by Emerson Network Power experts will ensure that your infrastructure performs at its best today and into the future. Emerson Network Power supports entire critical infrastructures with an extensive service offering, enhancing network availability and ensuring total peace of mind 24/7. With the broadest, most comprehensive service presence in the industry and more than 600 Customer Engineers dedicated to servicing Europe, Middle East and Africa, Emerson Network Power ensures that your business is protected 100% of the time and that assistance is close by whenever needed. Emerson Network Power Customer Engineers are experienced professionals who regular undergo intensive training programs and are certified according to country specific, European and international regulations and standards. 2 Emerson Network Power’s professional Critical Infrastructure Assessments are designed to provide facility managers with insight into the performance of their infrastructure. The assessments furthermore assist in identifying areas of optimization in availability and efficiency. In doing so, industry best practice parameters are used to measure and evaluate data center operation and performance. The assessments specifically evaluate the extent to which cooling and power architecture is leveraged, the level of redundancy, as well as the efficiency of the installed systems, presence of hot spots, the use of floor space and air distribution versus heat dissipation. The Assessments focus on: •Maximizing efficiency and uptime in data centers and telecom sites •Optimizing the utilization of power and cooling infrastructure •Analyzing the efficiency of heat removal generated by IT and telecom equipment •Identifying hot spots and potential risks •Assessing the capacity of electrical systems •Identifying electrical risks with the potential of leading to downtime Utilizing industry-leading assessment tools to deliver superior analysis allows our expert Customer Engineers to verify that equipment is correctly dimensioned for the current demands. It also enables them to provide advice on how and where the critical infrastructure can be strengthened to meet future demands. The comprehensive assessment report details recommendations for optimizing the performance, capacity, availability and efficiency of both cooling and power equipment. Assessment reports are backed up by Computational Fluid Dynamics (CFD) modeling and financial return on investment (ROI) calculations. Critical Infrastructure Assessments include: •Optimization and expansion strategies •On-site power and cooling assessment •Power Usage Effectiveness (PUE) analysis •Computational Fluid Dynamics (CFD) modeling •Documentation of findings and recommendations •Consultation and review of report findings •Contingency plan •IT Capacity strategy •Thermocamera Scan Audit Emerson Network Power’s Critical Infrastructure Audit provides a qualitative snapshot of the infrastructure’s overall health, evaluating its operation based on industry benchmarks. Providing insight into the current status of the infrastructure operation, the audit also serves as a means of evaluating if a more in depth analysis, such as a Critical Infrastructure Assessment or specific Power or Thermal Management Assessment is warranted. Expert Customer Engineers carry out site visits to validate the health status of the data center using results from Infrared Cameras to determine the current viability of the facility, as well as identify steps for greater flexibility, reliability and total cost of ownership (TCO) optimization. The remote data collection and analysis relates to the overall facility, as well as more specifically to: •Power and Cooling •Racks and Cabling •Monitoring Systems •Service Practices The result is a report of the overall analysis and recommendations for optimized site operation, capacity utilization, efficiency and availability providing evidence of: •Overall performance compared to industry benchmarks •Current risk cost/benefit analysis •Recommended action plan 3 Thermal Management Assessments Specific Thermal Management Assessments enhance IT system availability by identifying and eliminating hot spots, as well as providing vital recommendations for maximizing the performance and efficiency of cooling infrastructure, in addition to system expansion and optimization. This is achieved by carrying out an investigative on-site analysis measuring the effectiveness of the data center or telecom site’s critical equipment cooling Temperature (°C) 38 31 24 17 Computational Fluid Dynamics (CFD) modeling visually depicts the heat-related impact on data center facilities by simulating the outcome following the implementation of recommendations. 4 10 methods. The assessment is furthermore designed to identify airflow issues in existing room conditions and practices, accomplished through Computational Fluid Dynamics (CFD) modeling which illustrates the data center’s thermal condition and airflow patterns. Emerson Network Power comprehensive Thermal Management Assessments feature: •Air Temperature measurement •Air Flow measurement •Identification of hot spots through tools such as thermo cameras and Computational Fluid Dynamics (CFD) modeling •Comparison of IT /Telecom equipment load with cooling unit capacity •Computational Fluid Dynamics (CFD) modeling Temperature (°C) 38 31 24 17 10 5 Critical Power Assessment A dedicated Power Assessment will determine the power equipment performance, as well as identify energy saving opportunities at site, ensuring overall infrastructure availability. Using industry-leading tools, Emerson Network Power’s expert Customer Engineers assess the electrical infrastructure from the incoming power through to the critical load, with the objective of recommending actions for improving power-related performance, energy and other operating cost-savings while ensuring compliance with industry best practices and safety codes and standards. As with Emerson Network Power’s wider series of assessments, industry benchmarks and best practices are used as parameters for evaluation. 6 Emerson Network Power comprehensive Power Assessments feature: •Critical components thermal analysis •Power Usage Effectiveness (PUE) analysis •Single point of failure analysis •Switchgear equipment analysis •DC systems analysis including rated capacity, utilization and efficiency on rectifiers and inverters •UPS systems analysis including rated capacity, utilization and efficiency •Battery backup and battery optimization Reporting is a fundamental component of the Power Assessment in which the in depth evaluation of parameters measured, together with optimization recommendations and return on investment (ROI) calculations are detailed. It is moreover designed to provide data center professionals with clear recommendations and actions for immediate and future optimization of power infrastructure. Today’s successful businesses depend on adaptable technologies to help them respond quickly to market demands. Your critical infrastructure must be designed to match the power and cooling needs of rapidly changing IT initiatives such as virtualization and consolidation. Each change, move or addition will affect the entire support infrastructure so you need products and support that ensure your equipment will operate reliably in these environments. 7 Ensuring The High Availability Of Mission-Critical Data And Telecom Applications. About Emerson Network Power Emerson Network Power, a business of Emerson (NYSE:EMR), protects and optimizes critical infrastructure for data centers, communications networks, healthcare and industrial facilities. The company provides new-to-the-world solutions, as well as established expertise and smart innovation in areas including AC and DC power and renewable energy, precision cooling systems, infrastructure management, embedded computing and power, integrated racks and enclosures, power switching and controls, and connectivity. Our solutions are supported globally by local Emerson Network Power service technicians. Learn more about Emerson Network Power products and services at www.EmersonNetworkPower.eu While every precaution has been taken to ensure accuracy and completeness herein, Emerson assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice. MKA4L0UKDCA Rev. 2-04/2014 EmersonNetworkPower.eu Emerson. Consider it Solved, LIFE, Trellis, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. or one of its affiliated companies ©2014 Emerson Electric Co. All rights reserved.